Oil Resistant Flexible Control & Power Cablestevenengineering.com/Tech_Support/PDFs/52SEC1.pdf ·...
-
Upload
truongtuyen -
Category
Documents
-
view
216 -
download
2
Transcript of Oil Resistant Flexible Control & Power Cablestevenengineering.com/Tech_Support/PDFs/52SEC1.pdf ·...
OL
FL
EX
®
1
Oil Resistant Flexible Control & Power Cable
35
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
36 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
Oil Resistant Flexible Control & Power CablesN
EW
NE
W
QUICK SELECT CHART 38
FLEXIBLE UL/CSA PVC CONTROL CABLE
OLFLEX® 190/ 190 CY 40Extremely Oil Resistant Flexible Control CableNow with UL MTW to Comply with NFPA 79 2007
OLFLEX® 150/ 150 CY 42Oil Resistant Flexible Control Cable with International Approvals“Now with <HAR> Approval for use as a Machinery Interconnection Cable”
OLFLEX® CONTROL TM/ TM CY 44Flexible & Oil Resistant Tray and Machine CableUL MTW & UL/CSA TC Approval with Exposed Run for Industrial Applications
OLFLEX® CONTROL COLD 46Flexible & Cold Temperature Tray Cable with UL/CSA-45°C Flexible/ -55°C Stationary
FLEXIBLE EUROPEAN PVC CONTROL CABLE
OLFLEX® CLASSIC 100/ 100 CY 47Flexible Power and Control CablesColor Coded
OLFLEX® CLASSIC 100 SY 49Steel Braided, Flexible Power Control CableColor Coded
OLFLEX® CLASSIC 110/ 110 CY 50Flexible Control CableNumber Coded
OLFLEX® CLASSIC 110 SY 52Steel Braided, Flexible Control CableNumber Coded
OLFLEX® CLASSIC 110 Black 1000V 53UV Resistant Control Cable with Numbered Conductors
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
37800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
Oil Resistant Flexible Control & Power CablesN
EW
NE
WN
EW
FLEXIBLE HALOGEN-FREE CONTROL CABLE
OLFLEX® 110 H/ 110 CH 54Oil Resistant, Halogen-Free Control CableLSF OH (Low Smoke & Fume, Zero Halogen
OLFLEX® CLASSIC 130 H A/ 135 CH A 56Flexible Halogen-Free Cable with UL Approval
FLEXIBLE PUR & TPE CONTROL CABLES
OLFLEX® 490 P/ 490 CP 57Flexible Control Cable with Polyurethane Jacket
OLFLEX® 590 P/ 590 CP 59Heavy Duty, Low Halogen, Indoor/Outdoor Flexible Control Cable
OLFLEX® PUR S 61Flexible Cold-Resistant Polyurethane Control Cable with Superfine Conductor Stranding
OLFLEX® CONTROL M 62Flexible & Oil Resistant MTW Cable according to NFPA 79
OLFLEX® POWER MULTI 63Flexible & Oil Resistant Tray Cable and STOOW Extra Hard Service Cordage
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
38 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
PVC
PVC
PVC
PVC
PVC/ Nylon
PVC/ Nylon
PVC/ Nylon
PVC
PVC
PVC
PVC
PVC
PVC
PVC
Halogen-Free
Halogen-Free
Halogen-Free
Halogen-Free
PVC
PVC
TPE
TPE
PUR
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
HF Polymer
HF Polymer
HF Polymer
HF Polymer
PUR
PUR
PUR
PUR
PUR
Polymer
ElastomericAlloy
20 - 2
20 - 2
19 - 14
19 - 14
18 - 10
18 - 10
18 - 2
21 - 500KCMIL
21 - 350KCMIL
21 - 3/0
21 - 2
21 - 2
21 - 6
18 - 4/0
21 - 10
21 - 10
16 - 14
16 - 14
20 - 14
20 - 14
18 - 10
18 - 10
20 - 16
18 - 2
18 - 8
2, 3, 4, 5, 7, 9, 12, 18, 25
2, 3, 4, 5, 7, 12, 18, 25
3, 4, 5, 7, 12, 18, 25
3, 4, 5, 7
3, 4, 5, 7, 9, 10, 12, 15, 19,20, 25
3, 4, 5, 7, 9, 10, 12, 15, 19,20, 25
3, 4, 5, 7, 9, 12, 16, 18, 25
2, 3, 4, 5
2, 3, 4, 5
2, 3, 4, 5
2, 3, 4, 5, 7, 12, 18, 25, 34,35, 52, 65, 80, 100
2, 3, 4, 5, 7, 12, 18, 25
2, 3, 4, 5, 7, 12, 18, 25
3, 4, 5, 7, 12, 18, 25
3, 4, 5, 7, 12, 18, 25
3, 4, 5, 7, 12, 18, 25
2, 3, 4, 5, 7
2, 3, 4, 5
2, 3, 4, 5, 7, 9, 12, 18, 25,34, 41, 50, 61
2, 3, 4, 5, 7, 9, 12, 18, 25,34, 41, 50, 61
2, 3, 4, 5, 7
2, 3, 4, 5, 7
2, 3, 4, 5, 7, 12, 18, 25
3, 4, 5, 7, 9, 12, 18, 25, 33
3, 4, 5, 7, 12, 18, 25
Insulation Jacket AWGRange
ConductorCounts
QUICK SELECT CHART
OLFLEX® 190
OLFLEX® 190 CY
OLFLEX® 150
OLFLEX® 150 CY
OLFLEX® CONTROL TM
OLFLEX® CONTROL TM CY
OLFLEX® CONTROL COLD
OLFLEX® CLASSIC 100
OLFLEX® CLASSIC 100 CY
OLFLEX® CLASSIC 100 SY
OLFLEX® CLASSIC 110
OLFLEX® CLASSIC 110 CY
OLFLEX® CLASSIC 110 SY
OLFLEX® CLASSIC 110 Black 1000V
OLFLEX® 110 H
OLFLEX® 110 CH
OLFLEX® CLASSIC 130 H A
OLFLEX® CLASSIC 135 CH A
OLFLEX® 490 P
OLFLEX® 490 CP
OLFLEX® 590 P
OLFLEX® 590 CP
OLFLEX® PUR S
OLFLEX® CONTROL M
OLFLEX® POWER MULTI
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
39800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
UL, CSA, CE, FP 2007, RoHS
UL, CSA, CE, FP 2007, RoHS
UL, CSA, HAR, CE, CCC,RoHS
UL, CSA, HAR, CE, CCC,RoHS
UL, CSA, CE, NOM, FP 2007,RoHS
UL, CSA, CE, NOM, FP 2007,RoHS
UL, CSA, CE, NOM, RoHS
CE, RoHS
CE, RoHS
CE, RoHS
VDE, CE, RoHS
VDE, CE, RoHS
VDE, CE, RoHS
CE, RoHS
CE, RoHS
CE, RoHS
UL, CE, RoHS
UL, CE, RoHS
UL, CSA, CE, RoHS
UL, CSA, CE, RoHS
UL, CSA, CE, RoHS
UL, CSA, CE, RoHS
CE, RoHS
UL, CSA, CE, FP 2007, RoHS
UL, CSA, CE, FP 2007, RoHS
-40oC
-40oC
-40oC
-40oC
-40oC
-40oC
-55oC
-40oC
-40oC
-40oC
-40oC
-40oC
-40oC
-30oC
-40oC
-40oC
-40oC
-40oC
-20oC
-20oC
-50oC
-50oC
-40oC
-40oC
-40oC
90oC
90oC
90oC
90oC
90oC
90oC
90oC
80oC
80oC
80oC
80oC
80oC
80oC
80oC
80oC
80oC
70oC
70oC
80oC
80oC
80oC
80oC
80oC
105oC
90oC
600V
600V
600V
600V
1000V
1000V
1000V
500V750V500V750V500V750V
500V
500V
500V
1000V
500V
500V
600V
600V
600V
600V
600V
600V
300V
1000V
1000V
No
Yes
No
Yes
No
Yes
No
No
Yes
YesSteel
No
Yes
YesSteel
No
No
Yes
No
Yes
No
Yes
No
Yes
No
No
No
40
40
42
42
44
44
46
47
47
49
50
50
52
53
54
54
56
56
57
57
59
59
61
62
63
Approvals Low Temp
HighTemp
Voltage Shield Oil Flame MechanicalProperties
Page#
OR-0504030201
UltimateExcellentSuperiorAbove AverageAverage
FR-0504
03/3.10201
MP-0504030201
OilResistance:
OR
FlameResistance:
FR
MechanicalProperties:
MP
Cable Attributes, See Page 653
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
40 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® 190/ 190 CYExtremely Oil Resistant Flexible Control CableNow with UL MTW to Comply with NFPA 79 2007
Also available with the following options:• Blue or red insulation• Black overall jacket
Minimum Bending Radius- for installation: 4 x cable diameter- with shield: 6 x cable diameter
Temperature Range:- for flexible use: -5oC to +90oC- for stationary use: -40oC to +90oC
Nominal Voltage: 600V
Test Voltage: 3000V
Conductor Stranding: Class 5
Color Code: Black with white numbers, plus green/yellow ground, 2 conductor cable does not include ground
Approvals: UL: - AWM 2587 + 21098- Type MTW Oil Res I & II- UL 758 80oC, - Conforms to NFPA 79 2007
CSA: - AWM I/II A/B FT 1- CSA C22.2 210.2
Sec. 7.6.12.1, 8.8.8Additional: - Impact and Crush tests to UL 1277
Technical Data:
OLFLEX® 190 multi-conductor cable has the highest oil, coolant and solventresistant PVC jacket for control and power applications in an industrial environment. OLFLEX® 190 is designed for use in all electrical equipmentin dry, damp and wet conditions.
Recommended Applications:For Machinery: CNC machining centers, Grinding machines, Bottling equipment, Conveyors, Processing equipment, Assembly lines and Controlpanels
Application Advantages:• Extremely oil resistant (Oil Res I & II)• Meets NFPA 79 2007 machinery wiring
standard• Excellent industrial power and control
cable• Very flexible and number coded for
easy routing and terminating • Round jacket for optimal seal with a
SKINTOP® Strain Relief
OLFLEX® 190 CY Construction:Finely stranded bare copper conductors; specially blended PVC/ nylon insulation; dry lubricant; non-wicking fillers; grayinner PVC jacket; tinned copper braid (85% coverage); specially formulated oil resistant gray PVC jacket.
OLFLEX® 190 Construction:Finely stranded bare copper conductors; specially blended PVC/ nylon insulation; non-wicking fillers; dry lubricant; specially formulated oil resistant gray PVC jacket.
Oil Resistance:OR-04
FlameResistance:
FR-02
Motion Type:FL-02
MechanicalProperties:
MP-02
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS-SCPage 486
Complete the installation with:
OLFLEX® 190 16 AWG (1.5mm2) / 25C UL MTW RU AWM E63634- CSA AWM I/II A/B 600V 90oC FT1 LL53776
OLFLEX® 190 CY 16 AWG (1.5mm2) / 4C UL MTW RU AWM E63634- CSA AWM I/II A/B FT1 600V 90oC FT1 L53776
Availability:
Standard put-ups are100ft, 250ft, 500ft,and 1,000ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
41800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® 190 CY: Shielded Oil Resistant Flexible Control Cable
*2 conductor cable does not include ground wire.
20 AWG (10/30) 0.50 mm2
602002602003602004602005602007602009602012602018602025
18 AWG (19/30) 1.00 mm2
601802601803601803NG601804601805601807601809601812601818601825601834601841601850
16 AWG (28/30) 1.50 mm2
601602601603601604601605601607601609601612601618601625601634
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
234579121825
2334579121825344150
23457912182534
71013172330406083
1319
2531445675
113156213256313
182736456482
109163227309
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
6.46.77.27.88.49.610.712.414.9
7.07.4
8.08.69.310.712.014.716.424.226.528.2
7.78.18.89.5
10.311.914.216.418.626.5
3941516081
135168198243
4244
546484
118142207277494558697
57617591
120174210298416946
58617689
120201250295361
6366
8195
125176211309413735830
1038
8591
112136179260313444620
1408
No Ground
OLFLEX® 190: Oil Resistant Flexible Control Cable
.253
.265
.285
.308
.331
.379
.421
.487
.586
.277
.291
.314
.340
.367
.423
.471
.579
.656
.9531.0431.110
.303
.319
.345
.375
.406
.470
.557
.644
.7331.044
601641601650601661
14 AWG (46/30) 2.50 mm2
601402601403601404601405601407601409601412601418601425
12 AWG (56/.0117) 4 mm2
601203601204601205601207601211
10 AWG (82/.0117) 6 mm2
601003601004601005
8 AWG (74/.0159) 10 mm2
600804600805
6 AWG (119/.0159) 16 mm2
600604600605
4 AWG (182/.04) 25 mm2
600404600405
2 AWG (273/.04) 35 mm2
600204600205
415061
234579121825
345711
345
45
45
45
45
372454554
30456075
105135179269374
75100125176276
110147184
245306
393491
541676
8531066
29.130.132.9
8.69.09.8
10.711.614.316.018.522.2
10.611.512.614.618.9
12.514.515.8
17.719.4
22.124.3
30.133.2
33.436.9
123015001800
8793
122145192318402575860
156198238363398
222267321
435525
698842
10071244
14221749
183022322679
130138182216286473598855
1280
232295354540592
330398479
648782
10401254
15011853
21192606
1.1441.2191.294
.337
.356
.386
.421
.457
.563
.628
.729
.872
.417
.454
.497
.573
.745
.492
.570
.623
.695
.764
.870
.955
1.1841.306
1.3161.454
20 AWG (10/30) 0.50 mm2
602002CY602003CY602007CY602012CY602025CY
18 AWG (19/30) 1.00 mm2
601802CY601803CY601804CY601805CY601807CY601812CY601818CY601825CY
16 AWG (28/30) 1.50 mm2
601603CY601604CY601605CY601607CY601612CY601618CY601625CY
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
2371225
23457121825
3457121825
23274871
137
2634465468
107162213
48617091
156219292
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
8.48.7
10.312.617.2
9.09.39.9
10.611.314.117.219.4
10.010.711.512.216.718.922.8
6582
112180296
7582
105123139230317435
111128149181311456639
97122167268441
112122157183207342472648
166191222270464679952
.329
.341
.407
.497
.678
.353
.367
.390
.416
.443
.554
.678
.764
.395
.421
.451
.482
.656
.743
.897
14 AWG (46/30) 2.50 mm2
601403CY601404CY601405CY601407CY601412CY601418CY
12 AWG (56/.0117) 4 mm2
601203CY601204CY601205CY601207CY
10 AWG (82/.0117) 6 mm2
601003CY601004CY601005CY601007CY
8 AWG (74/.0159) 10 mm2
600804CY6 AWG (119/.0159) 16 mm2
600604CY4 AWG (182/.04) 25 mm2
600404CY2 AWG (273/.04) 35 mm2
600204CY
34571218
3457
3457
4
4
4
4
6986
106136226334
115146172225
155196238316
305
467
637
969
11.011.712.614.518.723.0
12.714.915.917.1
15.817.018.620.0
20.4
25.2
33.6
37.3
148181218283516740
226310359493
311385474638
569
1114
1266
2189
221269325421769
1102
337462535735
463574706950
848
1660
1886
3261
.432
.462
.497
.572
.736
.905
.500
.585
.628
.672
.623
.669
.731
.786
.803
.994
1.324
1.468
OLFLEX® 190/ 190 CYExtremely Oil Resistant Flexible Control CableNow with UL MTW to Comply with NFPA 79 2007
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
42 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® 150/ 150 CYOil Resistant Flexible Control Cable with International Approvals“Now with <HAR> approval for use as a Machinery Interconnection Cable”
Minimum Bending Radius- for installation: 4 x cable diameter- with shield: 6 x cable diameter
Temperature Range:- <HAR>: -40°C to +70°C- UL/CSA: -40°C to +90°C
Nominal Voltage:- <HAR>: 300/500V- UL/CSA: 600V
Test Voltage: 3000V
Conductor Stranding: Fine wire per VDE 0295,
Class 5, IEC 60228 Cl.5
Color Code: Black with white numbers, plus green/yellow ground
Approvals: UL: - AWM Style 2587 & 21098 CSA: - AWM I/II A/B FT1Additional: - <HAR> H05VV5-F
- CCC- China Compulsory Certificate*
Technical Data:
OLFLEX® 150 is an internationally approved 600 volt multi-conductor cable.It has UL & CSA AWM approval and <HAR> approval as a interconnectcable on the machine. OLFLEX® 150 has our highest rated PVC jacket forindustrial applications for oil, coolant and chemical resistance.
Recommended Applications:Control and power, Food & beverage, Processing equipment,Pharmaceutical equipment, Machinery sold domestically and exported toEurope.
Application Advantages:• Industrial grade PVC jacket
(Oil Res I & II)• International approvals UL/CSA/<HAR>• Flexible cable with pressure extruded
jacket for easy installation• Number coded conductors for easy
connection• CCC approval is available upon request
OLFLEX® 150 CY Construction:Finely stranded bare copper conductors; PVC insulation; conductors cabled with non-wicking fillers; dry lubricant; grayPVC inner jacket; tinned copper braid (85% coverage); specially formulated oil resistant gray PVC jacket.
OLFLEX® 150 Construction:Finely stranded bare copper conductors; PVC insulation; dry lubricant; conductors cabled with non-wicking fillers; specially formulated oil resistant gray PVC jacket.
Oil Resistance:OR-04
FlameResistance:
FR-02
Motion Type:FL-01
MechanicalProperties:
MP-01
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS-SCPage 486
Complete the installation with:
* Add C to the end of the part number for CCC approval. Minimums may apply.
Availability:
Standard put-ups are 250ft, 499ft, 1000ftand 2001ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
43800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® 150: Flexible Control Cable with Global Approvals
19 AWG (24/32) 0.75 mm2
001510300151040015105001510700151120015125
18 AWG (32/32) 1.00 mm2
0015203001520400152050015207001521200152180015225
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
34571225
3457121825
1519243458
121
1926324577
116161
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
6.77.28.19.9
12.017.5
7.17.78.7
11.513.015.418.7
51567697
165313
606789
114192272383
7684
113145245466
8999
132169286405570
.264
.283
.319
.390
.472
.689
.280
.303
.343
.453
.512
.606
.736
16 AWG (30/30) 1.50 mm2
0015303001530400153050015307001531200153180015325
14 AWG (50/30) 2.50 mm2
0015403001540400154050015407001541200154180015425
3457121825
3457121825
29394868
116174242
486581
113194290403
8.18.9
10.012.314.817.821.5
9.610.711.814.517.721.425.8
7495
113151243348491
114141173229390571790
110141168224362518730
170210257340580850
1175
.319
.350
.394
.484
.583
.701
.846
.378
.421
.465
.571
.697
.8431.016
OLFLEX® 150 CY: Shielded Flexible Control Cable with Global Approvals
19 AWG (24/32) 0.75 mm2
0015603001560400156050015607
18 AWG (32/32) 1.00 mm2
0015703001570400157050015707
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
3457
3457
46475262
51546479
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
8.99.6
10.312.3
9.510.111.113.1
84105121152
97121136183
125157180226
145180203273
.350
.378
.406
.484
.374
.398
.437
.516
16 AWG (30/30) 1.50 mm2
0015803001580400158050015807
14 AWG (50/30) 2.50 mm2
0015903001590400159050015907
3457
3457
56638296
81114138162
10.311.312.614.9
11.813.114.617.3
107142162205
164198245322
159211241306
245295365480
.406
.445
.496
.587
.465
.516
.575
.681
OLFLEX® 150/ 150 CYOil Resistant Flexible Control Cable with International Approvals“Now with <HAR> approval for use as a Machinery Interconnection Cable”
* Add C to the end of the part number for CCC approval. Minimums may apply.
* Add C to the end of the part number for CCC approval. Minimums may apply.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
44 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® CONTROL TM-(UL)TYPE TC-ER or MTW 90°C 600V---CSA AWM FT4 RoHS
Minimum bend radiusfor installation: 6 x cable diameter
Temperature Range: -40°C to +90°C
Nominal voltage: 600V - TC1000V- TC Wind Turbine
(WTTC)
Test voltage: 2000V
Color Code: Conductors are black printed with white numbers plus green/yellow ground
Approvals: UL: - UL Type TC-ER (Exposed Run)- AWM, UL Wet Approval 75°C- Type MTW, NFPA 79 2007- Class 1, Div. 2 per NEC Art.
336, 392, 501- UL Bus Drop - 14 AWG & Larger
3c & 4c only**CSA: - c(UL) CIC/TC FT4
- AWM I/II A/B FT4
Technical Data:
OLFLEX® CONTROL TM is a multi-conductor cable designed for use onmachine tool equipment and other industrial machinery conforming toNFPA 79 2007 wiring norms. OLFLEX® CONTROL TM is also UL/CSATC approved so it can be routed in tray as well.
Recommended Applications:Machine tool machinery, Food & beverage, Processing equipment,Machine wiring for conformance to NFPA 79 2007
Application Advantages:• Industrial grade PVC jacket (Oil Res 1)• Conforms to NFPA 79 2007 standards
for wiring machinery (UL MTW)• Gray jacket and number coded for easy
connection• UL TC-ER approval so it can be installed
off the machine and into an overhead tray• Flexible copper stranding and pressure
extruded jacket• Can be used in damp, dry & wet conditions
OLFLEX® CONTROL TM Construction:Finely stranded bare copper conductors; specially blended PVC/nylon insulation; specially formulated PVC jacket.
Oil Resistance:OR-02
FlameResistance:
FR-03
Motion Type:FL-01
MechanicalProperties:
MP-03
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINDICHT®
SDL:Page 533
Complete the installation with:
Available with a foil shield. Minimums may apply.
OLFLEX® CONTROL TM CY Construction:Finely stranded bare copper conductors; specially blended PVC/nylon insulation; overfoil and tinned copper braid (85%coverage); specially formulated PVC jacket.
OLFLEX® CONTROL TM CY-(UL)TYPE TC-ER or MTW 90°C 600V---CSA AWM FT4 RoHS
OLFLEX® CONTROL TM/ TM CYFlexible & Oil Resistant Tray and Machine Cable UL MTW & UL/CSA TC Approval with Exposed Run for Industrial Applications
Availability:
Standard put-ups are100ft, 250ft, 500ft,and 1,000ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
45800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
18 AWG (19/30) 1.00 mm2
281803281804281805281807281809281810281812281815281819281825
16 AWG (28/30) 1.50 mm2
281603281604281605281606281607281609281610281612281615281618281619281620281625
14 AWG (46/30) 2.50 mm2
281403**281404**281405
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
345791012151925
34567910121518192025
345
1925314456637594
119156
27364554648291
109145174172181227
456075
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
7.48.08.69.3
10.711.612.013.214.716.7
8.18.89.5
10.310.311.912.914.115.816.416.417.218.6
8.99.8
10.7
55647597
109115166207263312
678095
123123166184213246289286301312
84104124
8295
112144162171247308391464
100119141183183247273317366431426448464
125155185
OLFLEX® CONTROL TM: Flexible and Oil Resistant Tray & Machine Cable
.291
.315
.340
.367
.423
.457
.471
.520
.579
.656
.319
.345
.375
.406
.406
.470
.509
.551
.621
.644
.644
.676
.733
.356
.386
.421
281407281409281410281412281415281419281425
12 AWG (56/.0117) 4 mm2
281203**281204**281205281206281207281209281212281215281219281220281225
10 AWG (82/.0117) 6 mm2
281003**281004**281005281007281009281012281019
791012151925
3456791215192025
345791219
105135149179224284374
75100125151176226301376477502627
110147184257331441698
11.614.315.516.017.118.522.1
10.611.512.614.614.616.918.921.023.124.326.3
11.014.515.817.220.123.627.5
164218242298373450569
111148181250324360432540684720900
193257307430549737
1178
244324360443555670847
165220269372482536643804
101810711339
287382457640817
10971753
.457
.563
.609
.628
.693
.729
.872
.417
.454
.497
.573
.573
.665
.745
.825
.909
.9551.036
.492
.570
.623
.678
.791
.9301.084
** Meets UL Bus Drop Approval
18 AWG (19/30) 1.00 mm2
281803CY281804CY281805CY281807CY281809CY281810CY281812CY281815CY281819CY281825CY
16 AWG (28/30) 1.50 mm2
281603CY281604CY281605CY281606CY281607CY281609CY281610CY281612CY281615CY281619CY281620CY281625CY
14 AWG (46/30) 2.50 mm2
281403CY**281404CY**281405CY281407CY
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
345791012151925
345679101215192025
3457
344654689299
107138174213
4861708191
117131156186230241292
6986
106136
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
8.08.69.3
10.011.511.612.814.815.517.5
8.79.4
10.210.311.112.712.914.916.417.117.219.4
9.710.411.512.4
8092
100130167191222258294386
97116127142165211234286300340354476
121150180220
119137149193249284330384438574
144173189212246314348426447506527708
180223268327
OLFLEX® CONTROL TM CY: Shielded Flexible and Oil Resistant Tray & Machine Cable
.316
.339
.365
.392
.454
.457
.502
.583
.610
.687
.344
.370
.400
.406
.437
.501
.512
.588
.644
.675
.676
.764
.381.411.452.488
281409CY281410CY281412CY281415CY281419CY281425CY
12 AWG (56/.0117) 4 mm2
281203CY**281204CY**281205CY281206CY281207CY281209CY281212CY281215CY281219CY281220CY281225CY
10 AWG (82/.0117) 6 mm2
281003CY**281004CY**281005CY281007CY281009CY281012CY281019CY
91012151925
3456791215192025
345791219
171187226281359474
115146172199225301401501602627752
155196238316396531878
14.316.316.718.419.322.9
11.412.314.214.615.317.719.721.023.125.027.1
14.115.316.618.020.924.427.5
294321400440527704
160212261289453504604610759
10081260
270371412575768
10311319
438477595655784
1048
238315388430674750899908
113015001875
402552613856
114315341963
.594
.640
.659
.724
.760
.903
.448
.485
.560
.573
.604
.696
.776
.825
.909
.9861.067
.555
.601
.654
.709
.822
.9611.084
OLFLEX® CONTROL TM/ TM CYFlexible & Oil Resistant Tray and Machine Cable UL MTW & UL/CSA TC Approval with Exposed Run for Industrial Applications
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
46 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® CONTROL COLD -(UL)TYPE TC-ER OR DP-I 90OC 600V---c(UL) TC/CIC FT4--CSA AWM FT4 RoHS
OLFLEX® CONTROL COLDFlexible & Cold Temperature Tray Cable with UL/CSA-40oC Flexible/ -55oC Stationary
Minimum Bend Radiusfor installation: 5 x cable diameter
Temperature Range: -55oC to +90oC
Nominal Voltage: 600V - TC1000V- TC Wind Turbine
(WTTC)Conductor Stranding: Fine wire
OLFLEX® CONTROL COLD is a multi-conductor cable designed to be flexible at -40oC. The specially formulated PVC compound passes the -50o C MIL-DTL-915C motion test and -55oC UL coldimpact.
Recommended Applications:Wind energy, Forestry equipment, Oil & petrochem equipment, Cold temperature storage & packaging facilities
Application Advantages:• Arctic grade PVC jacket (-40oC flexible)• Passes MIL-DTL-915C figure 8 motion test at -50oC• Comparable performance for flexibility vs.
Rubber, TPE and PUR jacketed cables• Can be used in damp, dry & wet conditions and
is UV resistant
OLFLEX® CONTROL COLD Construction:Finely stranded bare copper conductors; specially blended PVC/nylon insulation; specially formulated black PVC jacket.
Oil Resistance:OR-01
FlameResistance:
FR-03
Motion Type:FL-01
MechanicalProperties:
MP-03
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS-SCPage 486
Complete the installation with:
Color Code: Black with white numbers plus grn/yel ground
Approvals: UL: - Type TC-ER (Exposed Run) or DP-1- Type MTW or UL AWM, NFPA 79
2007- Wet Rating UL 83 75oC- Class 1, Div. 2 per NEC Art. 336,
392, 501CSA: - c(UL) Type TC and CIC FT4
- CSA-AWM I/II A/B FT4
Technical Data:
18 AWG (19/30) 1.00 mm2
261803261804261805261807261809261812261818261825
16 AWG (28/30) 1.50 mm2
261603261604261605261607261609261612261616261618261625
14 AWG (46/30) 2.50 mm2
261403261404261405
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
34579121825
3457912161825
345
192531445675
113156
2736456482
109145163227
456075
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
7.58.18.89.5
10.912.114.917.2
8.38.99.7
10.512.114.415.816.618.8
9.210.010.8
576677
100112171245322
698398
127171220271289397
87107128
8598
115149167255365479
103124146189255328403431592
130159191
.297
.320
.346
.373
.429
.477
.587
.677
.325
.351
.381
.412
.476
.565
.621
.652
.741
.362
.392
.427
261407261409261412261418261425
12 AWG (56/.0117) 4 mm2
261204261205261207
10 AWG (82/.0117) 6 mm2
261004261005261007
8 AWG (74/.0159) 10 mm2
260804260805
6 AWG (119/.0159) 16 mm2
260604260605
4 AWG (182/.04) 25 mm2
2604042 AWG (273/.04) 35 mm2
260204
79121825
457
457
45
45
4
4
105135179269374
100125176
147184257
245306
393491
541
853
11.814.516.218.722.5
11.712.814.8
14.716.017.4
17.919.6
22.824.9
27.8
32.3
169225308439587
152187258
265317443
412518
580725
952
1394
252335459654874
226279384
394472661
615771
8641080
1418
2077
.463
.571
.636
.737
.886
.460
.503
.581
.578
.631
.686
.703
.772
.899
.982
1.094
1.272
Additional color code for the conductors and the jacket are available upon request. Minimums may apply.
Availability:
Standard put-ups are100ft, 250ft, 500ft,and 1,000ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
47800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® CLASSIC 100/ 100 CYFlexible Power and Control CableColor Coded
Minimum Bend Radius- for installation: 4 x cable diameter- with shield: 6 x cable diameter
Temperature Range: -40°C to +80°C
Nominal Voltage: 300/500 V (≤ 16 AWG)450/750 V (≥ 14 AWG)
Test Voltage: 4000V
Conductor Stranding: Fine Wire per VDE 0295, Class 5, IEC 60228 Cl.5
Color Code: Chart 6, Page 673
Approvals: Based on VDE specifications
Technical Data:
OLFLEX® CLASSIC 100 is a color coded, multi-conductor control and powercable for use in all electrical equipment in dry, damp or wet conditions. It isa European style cable conforming to CE and is available unshielded andshielded.
Recommended Applications:Control systems, Assembly lines, Control panels, Data processing equipment and other European influenced machinery specifications
Application Advantages:• European color code for power• Conforms to CE standards• Available with inner jacket and tinned
copper braid for EMI/RFI protection• Pressure extruded jacket for improved
flexibility
OLFLEX® CLASSIC 100 CY Construction:Finely stranded bare copper conductors; PVC insulation; conductors cabled with non-wicking fillers; dry lubricant; grayPVC inner jacket, tinned copper braid (85% coverage); transparent PVC jacket.
OLFLEX® CLASSIC 100 Construction:Finely stranded bare copper conductors; PVC insulation; conductors cabled with non-wicking fillers; dry lubricant; grayPVC jacket.
Oil Resistance:OR-01
FlameResistance:
FR-02
Motion Type:FL-01
MechanicalProperties:
MP-01
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS-SCPage 486
Complete the installation with:Availability:
Standard put-ups are164ft, 328ft, 1640ft,and 3280ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
48 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
(300/500 V)21 AWG (16/32) 0.50 mm2
001000000100010010002300100033
18 AWG (32/32) 1.00 mm2
001004100100420010043300100443
(450/750 V)16 AWG (30/30) 1.50 mm2
001006300100640010065300100663
14 AWG (50/30) 2.50 mm2
001008600100870010088300100893
12 AWG (56/28) 4 mm2
00101000010101300101023
10 AWG (84/28) 6 mm2
00101050010106300101073
8 AWG (80/26) 10 mm2
00103010010109300101103
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
2345
2345
2345
2345
245
345
345
7101316
13192632
19293948
32486581
52103129
116155194
194258323
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
5.45.76.26.7
6.56.97.78.4
7.58.18.9
10.0
8.99.6
10.711.8
10.612.713.9
12.613.815.6
15.917.619.7
28344048
43526570
587389
110
86109136163
126200239
214265329
342437532
42506071
647897
105
87109133163
128162203242
187297355
318394489
516650792
OLFLEX® CLASSIC 100: Flexible Power & Control
.213
.224
.244
.264
.256
.272
.303
.331
.295
.319
.350
.394
.350
.378
.421
.465
.417
.500
.547
.496
.543
.614
.626
.693
.776
6 AWG (128/26) 16 mm2
00103020010112300101133
4 AWG (200/26) 25 mm2
00103030010115300101163
2 AWG (280/26) 35 mm2
00103040010117300101183
1 AWG (400/26) 50 mm2
001030500101193
2/0 AWG (560/26) 70 mm2
001030600101203
3/0 AWG (485/24) 95 mm2
001030700101213
4/0 AWG (614/24) 120 mm2
001030800103093
300 KCMIL (765/24) 150 mm2
00103113350 KCMIL (942/24) 185 mm2
00103123500 KCMIL (1225/24) 240 mm2
00103103
345
345
345
34
34
34
34
4
4
4
310413516
484645806
677903
1129
9681290
13551806
18392451
23223096
3871
4774
6193
18.320.422.8
23.025.428.5
25.628.531.9
31.034.5
35.339.4
41.345.8
46.651.9
58.9
61.9
76.1
612730921
93210631343
118714161771
17181978
21392750
31423717
37764694
4570
5578
7090
91110871370
138815821998
176621062635
25562943
31824092
46755538
56266994
6800
8300
10550
.720
.803
.898
.9061.0001.122
1.0081.1121.256
1.2201.358
1.3901.551
1.6261.803
1.8352.043
2.319
2.437
2.996
(300/500)21 AWG (16/32) 0.50 mm2
003500100350020035003300352013
18 AWG (32/32) 1.00 mm2
003522000352210035222300352233
(450/750 V)16 AWG (30/30) 1.50 mm2
003500000354580035459300354603
14 AWG (50/30) 2.50 mm2
00350110035017300350123
12 AWG (56/28) 4 mm2
0035018300350133
10 AWG (84/28) 6 mm2
0035019300350143
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
2345
2345
2345
345
45
45
28313744
38445260
44536578
98112134
159220
214296
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
7.07.37.98.4
7.98.28.79.5
9.910.311.312.6
11.813.514.6
15.116.5
16.618.2
50566775
667587
103
89114137165
142208219
271321
352419
758399
112
98111130153
132170204246
211310326
403478
524624
OLFLEX® CLASSIC 100 CY: Shielded Flexible Power & Control
.276
.287.311.331
.311.323.343.374
.390
.406
.445
.496
.465
.531
.575
.594
.650
.654
.717
8 AWG (80/26) 10 mm2
0035021300352903
6 AWG (128/26) 16 mm2
0035022300350153
4 AWG (200/26) 25 mm2
0035023300350243
2 AWG (280/26) 35 mm2
0035025300350263
1 AWG (400/26) 50 mm2
003502732/0 AWG (560/26) 70 mm2
003502833/0 AWG (485/24) 95 mm2
003502934/0 AWG (614/24) 120 mm2
00354303300 KCMIL (765/24) 150 mm2
00354313350 KCMIL (944/24) 185 mm2
00354323
45
45
45
45
4
4
4
4
4
4
375480
540706
866972
11381327
1574
2039
2725
3511
4233
5210
21.123.1
23.926.8
29.432.6
32.436.0
38.8
43.7
50.4
56.8
62.2
67.8
566675
9361216
12791595
16731862
2259
2499
3931
5046
5242
6630
8431004
13951812
19032374
24892771
3362
3719
5849
7509
7800
9866
.831
.909
.9411.055
1.1571.283
1.2761.417
1.409
1.720
1.984
2.236
2.449
2.669
OLFLEX® CLASSIC 100/ 100 CYFlexible Power and Control CableColor Coded
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
49800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® CLASSIC 100 SYSteel Braided, Flexible Power Control CableColor Coded
OLFLEX® CLASSIC 100 SY is a color coded, multi-conductor control and powercable with a steel braided shield for mechanical and low frequency protection. Itis for use in all electrical equipment in dry, damp or wet conditions. It is aEuropean style cable conforming to CE. Recommended Applications:Control systems, Assembly lines, Control panels, Data processing equipment andother European influenced machinery.
Application Advantage:• Available with inner jacket and
steel braid for mechanical protection• Steel braid provides protection from
low frequency noise• Pressure extruded jacket for
improved flexibility
OLFLEX® CLASSIC 100 SY Construction:Finely stranded bare copper conductors; PVC insulation; conductors cabled with non-wicking fillers; dry lubricant; grayinner PVC jacket; steel braid (75% coverage); transparent PVC jacket.
** Additional configurations are available, please call your Lapp representative for more information.
(300/500 V)21 AWG (16/32) 0.50 mm2
001600100160020016003300160043
18 AWG (32/32) 1.00 mm2
001604200160430016044300160453
(450/750 V)16 AWG (30/30) 1.50 mm2
001606400160650016066300160673
14 AWG (50/30) 2.50 mm2
001608700160880016089300160903
12 AWG (56/28) 4 mm2
00161010016102300161033
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
2345
2345
2345
2345
245
7101316
13192632
19293948
32486581
52103129
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
7.88.18.59.2
8.58.8 9.5
10.1
9.39.7
10.211.1
12.112.613.915.2
13.615.717.1
58647283
92103121136
115128146180
164187228267
221307366
8795
107123
137154180202
172191217268
245278339397
329457545
.307
.319
.335
.362
.335
.346
.374
.398
.366
.382
.402
.437
.476
.496
.547
.598
.535
.618
.673
10 AWG (84/28) 6 mm2
00161060016107300161083
8 AWG (80/26) 10 mm2
0016110300161113
6 AWG (128/26) 16 mm2
0016113300161143
4 AWG (200/26) 25 mm2
0016116300161173
2 AWG (280/26) 35 mm2
0016118300161193
1 AWG (400/26) 50 mm2
001612032/0AWG (560/26) 70 mm2
001612133/0 AWG (485/24) 95 mm2
00161223
345
45
45
45
45
4
4
4
116155194
258323
413516
645806
9031129
1290
1806
2451
15.817.218.8
21.323.3
24.126.8
29.432.6
32.436.0
38.8
43.7
50.4
365461536
677803
9291168
13561654
17252138
2358
3228
4269
544687798
10091197
13841740
20212464
25703185
3514
4809
6361
.622
.677
.740
.838
.917
.9491.055
1.1571.283
1.2761.417
1.528
1.720
1.984
Minimum Bending Radiusfor installation: 6 x cable diameter
Temperature Range: -40oC to +80oC
Nominal Voltage: 300/500V (≤ 18 AWG)450/750V (≥ 16 AWG)
Test Voltage: 4000V
Conductor Stranding: Fine Wire per VDE 0295, Class 5, IEC 60228 Cl.5
Color Code: Chart 6, Page 673
Approvals: Based on VDE specifications
Technical Data:
Oil Resistance:OR-01
FlameResistance:
FR-02
Motion Type:FL-01
MechanicalProperties:
MP-01
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS-SCPage 486
Complete the installation with:Availability:
Standard put-ups are164ft, 328ft, 1640ft,and 3280ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
50 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® CLASSIC 110/ 110 CYFlexible Control CableNumber Coded
OLFLEX® CLASSIC 110 CY Construction:Finely stranded bare copper conductors; PVC insulation; conductors cabled with non-wicking fillers; dry lubricant; grayPVC inner jacket, tinned copper braid (85% coverage); transparent PVC jacket.
OLFLEX® CLASSIC 110 is a number coded, multi-conductor control andpower cable for use in all electrical equipment in dry, damp or wet condi-tions. It is a European style cable conforming to CE and is availableunshielded and shielded.
Recommended Applications:Control systems, Assembly lines, Control panels, Data processing equipment and other European influenced machinery specifications
Application Advantage:• Common European control cable• Conforms to CE standards• Available with inner jacket and tinned
copper braid for EMI & RFI protection• Pressure extruded jacket for
improved flexibility
OLFLEX® CLASSIC 110 Construction:Finely stranded bare copper conductors; PVC insulation; conductors cabled with non-wicking fillers; dry lubricant; grayPVC jacket.
Minimum Bend Radius:- for installation: 4 x cable diameter- with shield: 6 x cable diameter
Temperature Range: -40°C to +80°C
Nominal Voltage: 300/500V
Test Voltage: 4000V
Conductor Stranding: Fine Wire per VDE 0295, Class 5, IEC 60228 Cl.5
Color Code: Black with white numbers, plus green/yellow ground
Approvals: VDE Reg. No. 7030
Technical Data:
Oil Resistance:OR-01
FlameResistance:
FR-02
Motion Type:FL-01
MechanicalProperties:
MP-01
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS-SCPage 486
Complete the installation with:Availability:
Standard put-ups are164ft, 328ft, 1640ft,and 3280ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
51800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® CLASSIC 110/ 110 CYFlexible Control CableNumber Coded
* Additional configurations are available, please call your Lapp representative for more information.
21 AWG (16/32) 0.50 mm2
1119752111900311190041119005111900711190121119018111902511190351119052111906511190801119100
18 AWG (32/32) 1.00 mm2
11198521119203111920411192051119207111921211192181119225111923411192411119250111926511192801119300
16 AWG (30/30) 1.50 mm2
1119902111930311193041119305111930711193121119318
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
2345712182535526580100
234571218253441506580100
234571218
710131623395881
113168210258323
131926324577
116161258265323419516645
1929394868
116174
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
4.85.15.76.26.78.9
10.512.414.517.319.621.123.6
5.76.06.57.18.0
10.512.714.717.118.820.6 23.625.328.3
6.36.77.28.18.9
12.014.4
242836425488
126175172347433524655
3644536385
138202274370444536694844
1048
46567086
112188274
3542546381
131188261256517644780975
53657994
126205300408551661797
103312511560
6884
104128166279407
OLFLEX® CLASSIC 110: Flexible Control Cable
.189
.201
.224
.244
.264
.350
.413
.488
.571
.681
.772
.831
.929
.224
.236
.256
.280
.315
.413
.500
.579
.673
.740.811.929.996
1.114
.248
.264
.283
.319
.350
.472
.567
111932511193341119341111935011193651119380
14 AWG (50/30) 2.50 mm2
1119952111940311194041119405111940711194121119418111942511194341119450
12 AWG (56/28) 4 mm2
11195031119504111950511195071119511
10 AWG (84/28) 6 mm2
1119603111960411196051119607
8 AWG (80/26) 10 mm2
11196146 AWG (128/26) 16 mm2
11196244 AWG (200/26) 25 mm2
11196342 AWG (280/26) 35 mm2
11196441119645
253441506580
234571218253450
345711
3457
4
4
4
45
242329397484629774
32486581
113194290403548806
77103129181284
116155194271
258
413
645
9031129
16.919.421.323.526.728.8
7.58.18.9
10.011.114.817.820.824.429.4
9.910.812.113.417.6
11.713.014.516.0
16.2
18.8
23.5
26.430.1
376501602732940
1148
6889
110134179299436598812
1179
135167205274426
194245300403
397
731
1063
14151771
560746895
108913981708
101132163200267445648890
12081754
201249305407634
289365447600
590
1087
1582
21062635
.665
.764
.839
.9251.0511.134
.295
.319
.350
.394
.437
.583
.701
.819
.9611.157
.390
.425
.476
.528
.693
.461
.512
.571
.630
.638
.740
.925
1.0391.185
OLFLEX® CLASSIC 110 CY: Shielded Flexible Control Cable
21 AWG (16/32) 0.50 mm2
11357521135003113500411350051135007113501211350181135025
18 AWG (32/32) 1.00 mm2
11358521135203113520411352051135207113521211352181135225
16 AWG (30/30) 1.50 mm2
11359021135303
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
23457121825
23457121825
23
283137445493
105168
3844526076
126192261
4456
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
7.07.37.98.48.9
11.313.315.2
7.98.28.79.5
10.213.315.517.5
8.58.9
5056677589
136194254
667587
103124206288366
7991
758399
112132202289378
98111130153185307418544
117136
.276
.287.311.331.350.445.524.598
.311.323.343.374.402.524.610.689
.335
.350
113530411353051135307113531211353181135325
14 AWG (50/30) 2.50 mm2
1135403113540411354051135407
12 AWG (56/28) 4 mm2
11355041135505
10 AWG (84/28) 6 mm2
11356048 AWG (80/26) 10 mm2
11356146 AWG (128/26) 16 mm2
1135624
457121825
3457
45
4
4
4
6784
132188261360
98112134194
159188
214
375
540
9.610.311.314.817.220.1
10.311.312.613.9
13.414.7
15.8
19.0
22.2
110126159264362501
129157190249
233278
326
494
934
163188237393538745
192233283371
347413
485
735
1395
.378
.406
.445
.583
.677
.791
.406
.445
.496
.547
.528
.579
.622
.748
.874
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
52 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
* Additional configurations are available, please call your Lapp representative for more information.
OLFLEX® CLASSIC 110 SYSteel Braided, Flexible Control CableNumber Coded
OLFLEX® CLASSIC 100 SY is a number coded, multi-conductor control and power cable with a steel braided shield for mechanical and low frequencyprotection. It is a European style cable conforming to CE, for use in all electrical equipment in dry, damp or wet conditions.
Recommended Applications: Control systems, Assembly lines, Control panels, Data processing equipment and other European influenced machinery specifications
Application Advantage:• European style control & power cable• Conforms to CE standards• Available with inner jacket and steel
braid for mechanical protection• Steel braid provides protection from low
frequency noise• Pressure extruded jacket for improved
flexibility
OLFLEX® CLASSIC 110 SY Construction:Finely stranded bare copper conductors; PVC insulation; conductors cabled with non-wicking fillers; dry lubricant; grayinner PVC jacket; steel braid (75% coverage); transparent PVC jacket.
21 AWG (16/32) 0.50 mm2
11257521125003112500411250051125007112501211250181125025
18 AWG (32/32) 1.00 mm2
11258521125203112520411252051125207112521211252181125225
16 AWG (30/30) 1.50 mm2
1125902112530311253041125305
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
23457121825
23457121825
2345
710131623395881
131926324577
116161
19293948
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
7.88.18.59.29.7
11.913.915.6
8.58.89.5
10.111.013.915.918.1
9.39.7
10.211.1
5864728399
143196252
718095
110134208279368
86101116136
8795
107123147213291375
106119141164200309415548
128151173202
.307
.319
.335
.362
.382
.469
.547
.614
.335
.346
.374
.398
.433
.547
.626
.713
.366
.382
.402
.437
1125307112531211253181125325
14 AWG (50/30) 2.50 mm2
1125403112540411254051125407112541211254181125425
12 AWG (56/28) 4 mm2
112550311255041125505
10 AWG (84/28) 6 mm2
11256041125605
8 AWG (80/26) 10 mm2
11256146 AWG (128/26) 16 mm2
1125624
7121825
3457121825
345
45
4
4
68116174242
486581
113194290403
77103129
155194
258
413
11.915.417.620.3
11.112.113.214.318.221.424.4
12.714.015.1
16.217.7
19.4
22.4
167266362479
138167198251394553734
192234276
324389
491
930
248396538713
206249295373586823
1093
285348410
482579
731
1384
.469
.606
.693
.799
.437
.476
.520
.563
.717
.843
.961
.472
.551
.594
.638
.697
.764
.882
Minimum Bending Radiusfor installation: 6 x cable diameter
Temperature Range: -40oC to +80oC
Nominal Voltage: 300/500V
Test Voltage: 4000V
Conductor Stranding: Fine Wire per VDE 0295, Class 5, IEC 60228 Cl.5
Color Code: Black with white numbers, plus green/yellow ground
Approvals: VDE Reg. No. 7030
Technical Data:
Oil Resistance:OR-02
FlameResistance:
FR-03
Motion Type:FL-01
MechanicalProperties:
MP-01
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS-SCPage 486
Complete the installation with:Availability:
Standard put-ups are164ft, 328ft, 1640ft,and 3280ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
53800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® CLASSIC 110 Black 1000VUV Resistant Control Cable with Numbered Conductors
OLFLEX® CLASSIC 110 Black Construction:Finely stranded bare copper conductors, PVC insulation, conductors cabled with non-wicking fillers, black PVC jacket.
Minimum Bending Radiusfor installation: 4 x cable diameter
Temperature Range: -30°C to +80°C
Nominal Voltage: 600/1000V
Test Voltage: 4000V
Conductor Stranding: Fine Wire per VDE 0295, Class 5, IEC 60228 CL.5
Color Code: Black with white numbers, plus green/yellow ground
Approvals: Based on VDE specifications
Technical Data:
Oil Resistance:OR-01
FlameResistance:
FR-02
Motion Type:FL-01
MechanicalProperties:
MP-01
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS-SCPage 486
Complete the installation with:
* Additional configurations are available, please call your Lapp representative for more information.
18 AWG (32/32) 1.00 mm2
1120267 11202691120271 1120274 1120280 1120284 1120290
16 AWG (30/30) 1.50 mm2
1120307 1120309 1120311 1120314 1120320 1120324 1120328
14 AWG (50/30) 2.50 mm2
1120340 11203421120344 1120346 1120349 1120351
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
3457121825
3457121825
34571218
1926324577
116161
29394868
116174242
486581
113194290
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
9.09.6
10.411.114.016.118.6
10.110.811.712.616.118.821.7
11.312.213.314.418.722.0
7588
102132192282384
97114134175268368517
122151179238363529
112131152196286419572
144170199261399547770
182225266354540788
.354
.378
.409
.437
.551
.634
.732
.398
.425
.461
.496
.634
.740
.854
.445
.480
.524
.567
.736
.866
1120353 12 AWG (56/28) 4 mm2
1120360 11203611120362
10 AWG (84/28) 6 mm2
1120366 8 AWG (80/26) 10 mm2
1120370 6 AWG (128/26) 16 mm2
1120374 4 AWG (200/26) 25 mm2
1120378 2 AWG (280/26) 35 mm2
1120382 1 AWG (400/26) 50 mm2
1120385 2/0 AWG (560/26) 70 mm2
1120387 3/0 AWG (485/24) 95 mm2
1120389 4/0 AWG (614/24) 120 mm2
1120390
25
457
4
4
4
4
4
4
4
4
4
403
103129181
155
258
413
645
903
1290
1839
2451
3096
25.8
13.815.116.4
15.1
18.7
21.3
26.2
29.1
35.6
40.7
46.8
53.5
735
218259345
297
475
739
1075
1613
2285
3393
4038
5040
1094
324385513
442
707
1100
1600
2400
3400
5050
6010
7500
1.016
.543
.594
.646
.594
.736
.839
1.031
1.146
1.402
1.602
1.843
2.106
OLFLEX® CLASSIC 110 is a number coded, multi-conductor control andpower cable for use in all electrical equipment in dry, damp or wet conditions.It is a European style cable conforming to CE.
Recommended Applications:Control systems, Assembly lines, Control panels, Data processing equipment and other European influenced machinery specifications
Application Advantage:• 1000V European control cable• Conforms to CE standards• Pressure extruded jacket for improved
flexibility• Black UV resistant jacket for outdoor
use.
Availability:
Standard put-ups are164ft, 328ft, 1640ft,and 3280ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
54 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® CLASSIC 110 H/ 110 CHOil Resistant, Halogen-Free Control CableLSF OH (Low Smoke & Fume, Zero Halogen)
OLFLEX® CLASSIC 110 CH Construction:Finely stranded bare copper conductors, halogen-free polymer compound, halogen-free inner jacket, tinned copper braidshield (85% coverage), specially formulated oil resistant gray halogen-free polymer jacket
OLFLEX® CLASSIC 110 H is a halogen-free, multi-conductor control andpower cable with improved oil resistance and flame protection. It is for usein all electrical equipment in dry or damp conditions. It is UV resistant atnormal temperatures and is available unshielded and shielded.
Recommended Applications:Amusement rides, Theater stages and other areas where human safety is aconcern. Also suitable, on machinery due to its improved oil resistance.
Application Advantage:• Completely recyclable, low toxicity of
smoke gases (NES 713 Part 3) and low smoke density (IEC 61034)
• No flame propagation for cables ≥ 18/7c (IEC 60332-3-24) and flame retardant (IEC 60332-1-2)
• Oil resistant (SEV TB 20 B)• Hydrolysis resistant (HD 22.10)
OLFLEX® CLASSIC 110 H Construction:Finely stranded bare copper conductors, halogen-free polymer compound, specially formulated oil resistant gray halogen-free polymer jacket
Minimum Bend Radius- for installation: 4 x cable diameter- with shield: 6 x cable diameter
Temperature Range: -40°C to +80°C
Nominal Voltage: 300/500V
Test Voltage: 4000V
Conductor Stranding: Fine Wire per VDE 0295, Class 5, IEC 60228 Cl.5
Color Code: Black with white numbers, plus green/yellow ground
Approvals: Based on VDE specifications
Technical Data:
Oil Resistance:OR-03
FlameResistance:
FR-03
Motion Type:FL-01
MechanicalProperties:
MP-01
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS-SCPage 486
Complete the installation with:Availability:
Standard put-ups are164ft, 328ft, 1640ft,and 3280ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
55800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® CLASSIC 110 H/ 110 CHOil Resistant, Halogen-Free Control CableLSF OH (Low Smoke & Fume, Zero Halogen)
21 AWG (16/32) 0.50 mm2
0019901 0019903001990500199060019907
18 AWG (32/32) 1.00 mm2
0019961001996300199650019967001996900199710019972
16 AWG (30/30) 1.50 mm2
00199310019932 0019933 0019934 001993500199370019938
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
345712
3457121825
3457121825
1013162339
1926324577
116161
29394868
116174242
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
5.55.96.57.58.5
6.26.87.49.2
11.012.816.1
6.97.58.6
10.612.314.418.6
3238445789
49577188
148212302
647997
123206312440
47576685
133
7385
105131220315449
95117144183307465655
OLFLEX® CLASSIC 110 H: Oil Resistant Halogen-Free Control Cables
.217
.232
.256
.295
.335
.244
.268
.291
.362
.433
.504
.634
.272
.295
.339
.417
.484
.567
.732
14 AWG (50/30) 2.50 mm2
0019945 0019946001994700199480019949
12 AWG (56/28) 4 mm2
001995000199510019952
10 AWG (84/28) 6 mm2
001995300199540019975
345712
457
457
486581
113194
103129181
155194271
8.89.6
11.012.915.2
11.212.214.4
13.214.917.6
102129163208352
201244328
323392525
152192243310524
299363488
480583782
.346
.378
.433
.508
.598
.441
.480
.567
.520
.587
.693
21 AWG (16/32) 0.50 mm2
0035031 00350330035035 00350360035037
18 AWG (32/32) 1.00 mm2
0035056 0035058 0035060 0035061 0035062 0035063 0035064
16 AWG (30/30) 1.50 mm2
0035068 0035070 0035071 0035072 0035073 0035074 0035075
14 AWG (50/30) 2.50 mm2
0035089 0035090 0035091 0035092 0035093
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
345712
3457121825
3457121825
345712
3137445491
44526076
126192261
566784
132188261360
98112134194321
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
7.37.78.39.9
11.2
8.09.29.8
11.213.215.419.3
9.39.9
10.612.814.518.221.6
10.811.613.215.519.0
718390
108159
94108122144237345455
126135155208339451642
142239259335612
106123134160237
140160182215352514677
187201231310505671955
211356386498911
OLFLEX® CLASSIC 110 CH: Oil Resistant Shielded Halogen-Free Control Cables
.287
.303
.327
.390
.441
.315
.362
.386
.441
.520
.606
.760
.366
.390
.417
.504
.571
.717
.850
.425
.457
.520
.610
.748
12 AWG (56/28) 4 mm2
0035094 0035095 0035096
10 AWG (84/28) 6 mm2
0035097 0035098 0035099
8 AWG (80/26) 10 mm2
0035380 6 AWG (128/26) 16 mm2
00353824 AWG (200/26) 25 mm2
0035384 2 AWG (280/26) 35 mm2
0035386 1 AWG (400/26) 50 mm2
0035388 2/0 AWG (560/26) 70 mm2
0035390 3/0 AWG (485/24) 95 mm2
0035392
457
457
4
4
4
4
4
4
4
159188261
214304353
375
540
866
1138
1574
1998
2725
13.414.718.2
15.418.220.9
24.4
27.9
32.7
36.8
42.4
47.6
51.7
308357515
411517695
663
899
1363
1780
2514
3396
4319
458532766
611770
1035
986
1338
2028
2649
3741
5054
6427
.528
.579
.717
.606
.717
.823
.961
.098
1.287
1.449
1.669
1.874
2.035
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
56 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® CLASSIC 135 CH A Construction:Finely stranded bare copper conductors, halogen-free polymer compound, halogen-free inner jacket, tinned copper braidshield (85% coverage), specially formulated oil resistant gray halogen-free polymer jacket
OLFLEX® CLASSIC 130 H A/ 135 CH AFlexible Halogen-Free Cable with UL Approval
OLFLEX® CLASSIC 130 H A is a halogen-free, multi-conductor control andpower cable with low smoke and flame protection. It is UL AWM and VW-1approved. OLFLEX® CLASSIC 135 CH A is a shielded cable with an overalltinned copper braid for EMI & RFI protection.
Recommended Applications:Amusement rides, Theater stages, and other areas where human safety is aconcern. Also suitable, on machinery where there is a high risk for fire.
Application Advantage:• Completely recyclable, low toxicity of
smoke gases and low smoke density • No flame propagation for cables ≥ 18/7c
(IEC 60332-3-24) and flame retardant (IEC 60332-1-2)
• Hydrolysis resistant (HD 22.10)• UL AWM style 21089 & VW-1
OLFLEX® CLASSIC 130 H A Construction:Finely stranded bare copper conductors, halogen-free polymer compound, specially formulated oil resistant gray halogen-free polymer jacket
Oil Resistance:OR-01
FlameResistance:
FR-02
Motion Type:FL-01
MechanicalProperties:
MP-01
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS-SCPage 486
Complete the installation with:
Minimum Bending Radius- 130 H A: 4 x cable diameter- 135 CH A: 6 x cable diameter
Temperature Range:- for flexible use: -15oC to +70oC- for stationary use: -40oC to +70oC
Nominal Voltage: 600V
Test Voltage: - core/ core: 4000V- core/ shield: 2000V
Color Code: Black with white numbers, plus grn/yel gnd, 2 conductor does not include ground
Approvals: UL: - AWM 10701 & 21089- UL 1581 VW-1
Additional: - Flame Retardant- IEC 60332-3-24- IEC 60332-1-2
Technical Data:
OLFLEX® CLASSIC 130 H A
16 AWG (1.50 mm2)1123106A1123107A1123109A
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
234
192939
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
6.36.77.3
485974
7288
110
.248
.264
.287
1123111A1123114A
14 AWG (2.50 mm2)1123142A
57
4
4868
65
8.18.9
8.9
91117
117
135174
174
.319
.350
.350
*2 conductor does not include ground wire.
OLFLEX® CLASSIC 135 CH A
16 AWG (1.50 mm2)1123306A1123307A1123309A
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
234
445567
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
7.17.58.2
617595
91112141
.280
.295
.323
1123311A14 AWG (2.50 mm2)
1123342A
5
4
80
99
8.9
9.9
108
135
161
201
.350
.390
Other configurations are available upon request. Minimums may apply.
Availability:
Standard put-ups are164ft, 328ft, 1640ft,and 3280ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
57800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® 490 P AWM 80OC 600V --- CSA AWM II A/B FT1 RoHS
OLFLEX® 490 CP AWM 80OC 600V --- CSA AWM II A/B FT1 RoHS
OLFLEX® 490 P/ 490 CPFlexible Control Cable with Polyurethane Jacket
OLFLEX® 490 P is a flexible control cable with a rugged, highly abrasionresistant polyurethane jacket. It is UV resistant and performs very well inmineral oils, cutting oils and areas with high mechanical abuse. OLFLEX®
490 CP is the shielded version with an overall foil tape with drain wire andtinned copper braid for EMI & RFI protection.
Recommended Applications:Machine tool equipment, Hand held controls, Submersible applications andany areas where the cable can be cut and damaged by sharp objects.
Application Advantage:• Rugged PUR jacket to resist cuts, nicks
and abrasion• UL & CSA AWM approved• Extremely oil and chemical resistant • Able to be dragged on the floor with
minimal damage if any at all• Number coded for easy wiring
OLFLEX® 490 CP Construction:Finely stranded bare copper conductors; specially blended PVC insulation; non-wicking fillers; dry lubricant; overall foiltape wrap with drain wire; tinned copper braid (85% coverage); specially blended oil resistant gray polyurethane jacket.
OLFLEX® 490 P Construction:Finely stranded bare copper conductors; specially blended PVC insulation; non-wicking fillers; dry lubricant; overall tapewrap; specially formulated oil resistant gray polyurethane jacket.
Oil Resistance:OR-05
FlameResistance:
FR-02
Motion Type:FL-01
MechanicalProperties:
MP-05
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS-SCPage 486
Complete the installation with:
Minimum Bend Radius- for installation: 4 x cable diameter- shielded: 6 x cable diameter
Temperature Range:- for flexible use: -10°C to +80°C- stationary applications: -20°C to +80°C
Nominal Voltage: 600V
Test Voltage: 3000V
Conductor Stranding: Fine wire
Color Code: Black with white numbers, plus green/yellow ground
Approvals: UL: AWM Style 20234CSA: AWM II A/B FT1
Technical Data:
Availability:
Standard put-ups are100ft, 250ft, 500ft,and 1,000ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
58 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® 490 P/ 490 CPFlexible Control Cable with Polyurethane Jacket
20 AWG (10/30) 0.50 mm2
402002402003402004402005402007402009402012402018402025
18 AWG (19/30) 1.00 mm2
401802401803401804401805401807401809401812401818401825401834401841401850401861
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
234579121825
23457912182534415061
71013172330406083
13192531445675
113156213256313381
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
6.26.57.07.48.09.0
10.211.713.6
6.87.17.78.38.9
10.111.513.215.417.218.920.121.8
35394754678198
138176
4552647592
115143203265365419488600
52587080
100121146205262
677795
112137171213302394543624726893
OLFLEX® 490 P: Flexible Control Cable with Polyurethane Jacket
.245
.256
.274
.293
.313
.355
.401
.459
.534
.269
.281
.303
.325
.349
.399
.451
.519
.607
.679
.743
.791
.859
16 AWG (26/30) 1.50 mm2
401602401603401604401605401607401609401612401618401625401641401650401661
14 AWG (41/30) 2.50 mm2
401402401403401404401405401407401409401412401418401425
234579121825415061
234579121825
182736456482
109163227372454553
30456075
105135179269374
7.57.98.59.19.9
11.312.614.616.621.223.024.5
8.48.89.5
10.311.212.914.416.119.2
53637791
114142179254335359642765
6676
101120155194237356473
7994
115135170211266378499534955
1138
98113150179231289353530704
.295
.310
.333
.360
.388
.446
.496
.574
.654
.834
.910
.966
.329
.347
.374
.406
.439
.507
.567
.659
.754
20 AWG (10/30) 0.50 mm2
402002CP402003CP402004CP402005CP402007CP402009CP402012CP402018CP402025CP
18 AWG (19/30) 1.00 mm2
401802CP401803CP401804CP401805CP401807CP401809CP401812CP401818CP401825CP401834CP401841CP401850CP401861CP
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
234579121825
23457912182534415061
23273238486271
101137
263446546892
107162213273326393471
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
6.97.17.68.18.69.7
10.812.414.4
7.57.88.38.99.5
10.812.013.715.518.019.721.422.6
4656657385
103116164214
61718294
116140177240311427501600699
688397
109126153173244318
91106122140173208263357463635746893
1040
OLFLEX® 490 CP: Shielded Flexible Control Cable with Polyurethane Jacket
.270
.281
.299
.318
.338
.380
.426
.490
.565
.294
.306
.328
.350
.374
.424
.473
.540
.609
.710
.774
.842
.890
16 AWG (26/30) 1.50 mm2
401602CP401603CP401604CP401605CP401607CP401609CP401612CP401618CP401625CP401641CP401650CP401661CP
14 AWG (41/30) 2.50 mm2
401402CP401403CP401404CP401405CP401407CP401409CP401412CP401418CP401425CP
234579121825415061
234579121825
3648617091
117156219292452554673
526986
106136171226334474
8.18.59.19.8
10.512.913.415.417.422.523.925.3
9.09.4
10.110.911.913.715.217.519.9
728296
112137169216294383643750888
84102124145182226287391557
107122143167204251321438570957
11161321
125152185216271336427582829
.320
.335
.358
.385
.413
.477
.527
.605
.685
.885
.941
.997
.354
.372
.399
.431
.470
.538
.598
.690
.785
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
59800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® 590 P AWM 80OC 600V --- AWM II A/B FT1
OLFLEX® 590 CP AWM 80OC 600V - AWM II A/B FT1
OLFLEX® 590 P/ 590 CPHeavy Duty, Low Halogen, Indoor/Outdoor Flexible Control Cable
OLFLEX® 590 P is a color coded, flexible power and control cable with arugged, highly abrasion resistant yellow polyurethane jacket. It is UV resistant and performs very well in cold temperature, indoor and outdoorapplications. OLFLEX® 590 CP is the shielded version with an overall foiltape with drain wire and tinned copper braid for EMI & RFI protection.
Recommended Applications:Portable hand tools, Utility and Forestry trucks & equipment, Cold climate/temperature applications and any areas where the cable can be cut anddamaged by sharp objects.
Application Advantage:• Rugged PUR jacket to resist cuts, nicks
and abrasion• TPE insulation for superior cold
temperature flexibility• Safety colored yellow jacket• Good for wet & dry areas• UL & CSA AWM approved
OLFLEX® 590 CP Construction:Finely stranded tinned copper conductors; TPE insulation; conductors cabled with non-wicking fillers; overall foil tapeshield with drain wire; tinned copper braid (85% coverage); yellow polyurethane jacket.
OLFLEX® 590 P Construction:Finely stranded tinned copper conductors; TPE insulation; conductors cabled with non-wicking fillers; overall tape wrap;yellow polyurethane jacket.
Oil Resistance:OR-05
FlameResistance:
FR-02
Motion Type:FL-01
MechanicalProperties:
MP-05
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS-SCPage 486
Complete the installation with:
Minimum Bending Radius- for flexible use: 5 x cable diameter- shielded: 8 x cable diameter
Temperature Range:for flexible use andstationary applications: -50oC to +80oC
Nominal Voltage: 600V
Test Voltage: 3000V
Conductor Stranding: Fine wire
Color Code: Chart 1, Page 671
Approvals: UL: AWMCSA: AWM FT1
Technical Data:
Availability:
Standard put-ups are100ft, 250ft, 500ft,and 1,000ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
60 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® 590 P/ 590 CPHeavy Duty, Low Halogen, Indoor/Outdoor Flexible Control Cable
18 AWG (19/30) 1.00 mm2
501802501803501804501805501807
16 AWG (26/30) 1.50 mm2
501602501603501604501605501607
14 AWG (41/30) 2.50 mm2
501402501403501404501405501407
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
23457
23457
23457
1319253144
1827364564
30456075
105
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
7.47.88.49.19.9
8.08.49.19.8
10.6
8.79.19.9
10.711.6
4350647795
50637790
116
6482
101123156
647495
115142
7594
115134172
95122150183232
OLFLEX® 590 P: Heavy Duty, Low Halogen, Indoor/ Outdoor Flexible Control Cable
.293
.308
.332
.357
.390
.315
.331
.357
.387
.418
.341
.360
.389
.422
.457
12 AWG (65/30) 4 mm2
501203501204501205
10 AWG (105/30) 6 mm2
501003501004501005
345
345
50100125
110147184
10.111.312.4
12.313.514.7
116146178
161205252
173218265
240305375
.399
.447
.487
.485
.532
.579
18 AWG (19/30) 1.00 mm2
501802CP501803CP501804CP501805CP501807CP
16 AWG (26/30) 1.50 mm2
501602CP501603CP501604CP501605CP501607CP
14 AWG (41/30) 2.50 mm2
501402CP501403CP501404CP501405CP501407CP
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
23457
23457
23457
2634465468
3648617091
526986
106136
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
8.08.49.09.6
10.5
8.89.29.9
10.611.4
9.49.9
10.711.612.5
62728499
118
7286
100117149
90109130160196
92107125148176
107128149174222
134162194238291
OLFLEX® 590 CP: Shielded Heavy Duty, Low Halogen, Indoor/ Outdoor Flexible Control Cable
.315
.330
.354
.379
.412
.346
.362
.388
.418
.449
.372
.391
.420
.458
.493
12 AWG (65/30) 4 mm2
501203CP501204CP501205CP
10 AWG (105/30) 6 mm2
501003CP501004CP501005CP
345
345
115146172
155196238
11.212.213.2
13.214.316.1
156189231
215262315
232282344
320390469
.442
.479
.518
.521
.564
.635
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
61800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® PUR S 17: Colored Conductors
OLFLEX® PUR SFlexible Cold-Resistant Polyurethane Control Cable with Superfine Conductor Stranding
OLFLEX® PUR S Construction:Extra fine stranded plain copper conductors; polyurethane insulation; and black PUR outer jacket.
Minimum Bending Radius for flexible use: 15 x cable diameter
Temperature Range:for flexible use: -30oC to +80oC
Nominal Voltage: 300/500V
Test Voltage: 3000V
Conductor Stranding: Fine Wire per VDE 0295, Class 6
Color Code:- PUR S 17: Chart 9, Page 674- PUR S 27: Numbered Conductors
Approvals: For machinery in accordance with SS EN 60204-1: 1992 “Electrical Equipment On Industrial Machines”
Technical Data:
Oil Resistance:OR-05
FlameResistance:
FR-01
Motion Type:FL-01
MechanicalProperties:
MP-05
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS:Page 486
Complete the installation with:
OLFLEX® PUR S is a highly flexible PUR insulated and PUR jacketed control cable. It has excellent oil and abrasion resistance and cold temperature performance.
Recommended Applications:Forestry equipment, Farming equipment, Utility trucks and other cold temperature applications where abrasion and flexibility are required.
Application Advantage:• Very good cold temperature performance• Excellent oil and abrasion resistance• Halogen-Free• Cold Climate/ Rigid Applications
20 AWG3800096938000975
18 AWG3800098038000981380009823800098338000984
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
212
23457
740
1319253144
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
5.39.5
5.86.16.77.38.6
639
1116222634
1058
1624323850
.209
.374
.228
.240
.264
.287
.339
38000987380009883800098938000991
16 AWG380010053800100638001013
12151825
2312
7594
113156
1827
109
10.712.112.915.4
7.07.4
13.6
657387
121
2030
116
96108130180
3045
173
.421
.476
.508
.606
.276
.291
.535
OLFLEX® PUR S 27: Numbered Conductors
20 AWG3800256038002561
18 AWG38002567380025693800257138002947
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
34
3457
1013
13253144
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
5.66.1
6.16.77.38.6
1013
16222634
1520
24323850
.220
.240
.240
.264
.287
.339
380029483800294938000332
17 AWG38000424
16 AWG3800257438003270
121825
25
34
75113156
156
2736
10.712.915.4
16.3
7.48.3
6587
121
161
3040
96130180
240
4560
.421
.500
.606
.642
.291
.327
Availability:
Standard put-ups are164ft, 328ft, 1640ft,and 3280ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
62 800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® CONTROL M (UL)TYPE TC-ER OR MTW 90oC 600V- c(UL) CIC/TC CSA AWM FT4 RoHS
OLFLEX® CONTROL MFlexible & Oil Resistant MTW Cable according to NFPA 79
OLFLEX® CONTROL M Construction:Finely stranded bare copper conductors; specially blended PVC/ nylon insulation; formulated oil and elastomeric polymer grayjacket.
Minimum Bending Radiusfor installation 5 x cable diameter
Temperature Range:- flexible: -10oC to +90oC- stationary: -40oC to +105oC
Nominal Voltage: 600V - TC1000V- TC Wind TurbineWTTC
Conductor Stranding: Fine wire, Class K and Class 5
Color Code: Black, Red, Blue, Orange or Yellow conductorswith printed numbers plus green/yellow ground.Other colors available upon request.
Approvals: UL: - Type MTW 90oC Oil Res. I/II or AWM 105oC
- NFPA 79 2007 compliant- Wet Approval 75oC- Type TC-ER
CSA: - c(UL) CIC/TC FT4- AWM I/II A/B
Technical Data:
Oil Resistance:OR-03
FlameResistance:
FR-03
Motion Type:FL-02
MechanicalProperties:
MP-03
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
SKINTOP®
MS-SCPage 486
Complete the installation with:
OLFLEX® CONTROL M is a elastomeric polymer jacketed, multi-conductor cable designed for use on machine tool equipment andother industrial machinery conforming to NFPA 79 2007 wiringnorms. OLFLEX® CONTROL M is cut and abrasion resistant.
Recommended Applications:Machine tool machinery, Food & beverage, Processing equipment, Automotive and machine wiring for conformance to NFPA 79 2007
Application Advantage:• Industrial grade polymer jacket• Conforms to NFPA 79 2007 standards for wiring
machinery• UL TC-ER, MTW & CSA CIC/TC approved, UV
Resistant• Extremely oil and chemical resistant (Oil Res I/ II) • Colored cores for AC, DC and control circuits
18 AWG (19/30) 1.00 mm2
431803*431804*431805*431807*431812*431818*431825*
16 AWG (28/30) 1.5 mm2
431603*431604*431605*431607*431609*431612*431618*431619*431625*431633*
14 AWG (46/30) 2.5 mm2
431403* 431404* 431405*
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
3457121825
345791218192533
345
1925314475
113156
2736456482
109163172227299
456075
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
7.68.18.89.5
12.114.916.9
8.38.99.7
10.512.114.416.616.618.821.0
8.810.010.8
576677
100112245322
698398
127171220289289397471
87107128
8598
115149255365479
103124146189255328431431592702
130159191
.297
.320
.346
.373
.477
.587
.664
.325
.351
.381
.412
.476
.565
.652
.652
.741
.827
.362
.392
.427
431407*431409*431412*431418*431425*
12 AWG (56/.0117) 4 mm2
431204*431205* 431207*
10 AWG (82/.0117) 6 mm2
431004*431005* 431007*
8 AWG (74/.0159) 10 mm2
430804*6 AWG (119/.0159)16 mm2
430604*430605*
4 AWG (413/30) 25 mm2
430404*2 AWG (665/30) 35 mm2
430204*
79121825
457
457
4
45
4
4
105135179269374
100125176
147184257
245
393491
541
853
11.814.516.218.722.5
11.712.814.8
14.716.017.4
17.9
22.824.9
27.8
32.3
252335459654874
226279384
394472661
615
8641080
1418
2077
.463
.571
.636
.737
.886
.460
.503
.581
.578
.631
.686
.703
.899
.982
1.094
1.272
169225308439587
152187258
265317443
412
580725
952
1394
Standard Conductors are Black. Replace * with B for (Blue), R for (Red), Y for (Yellow), or O for (Orange). Ex. 431803B has blue conductors.
Availability:
Standard put-ups are100ft, 250ft, 500ft,and 1,000ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
63800-774-3539 • www.lappusa.com • www.lappcanada.com • www.lappmexico.com
OLFLEX® POWER MULTI -(UL)TYPE TC-ER OR UL TYPE STOOW-- CSA TYPE STOOW c(UL) TC/CIC FT4
Foil shield with drain wire available upon request. Minimum may apply
OLFLEX® POWER MULTIFlexible & Oil Resistant Tray Cable and STOOW Extra Hard Service Cordage
OLFLEX® POWER MULTI Construction:Finely stranded bare copper conductors; specially blended PVC/ nylon insulation; specially formulated oil and chemical resistant black elastomeric alloy jacket.
Minimum Bending Radiusfor installation: 5 x cable diameter
Temperature Range: -40oC to +90oC
Nominal Voltage: 600V- TC, STOOW1000V- Wind Turbine
WTTC
Conductor Stranding: Fine wire
Color Code: 3/c: Black, White, Green/Yellow4/c: Black, White, Red, Green/ Yellow5/c: Black, White, Red, Brown, Green/Yellow(3c, 4c, & 5c: Color & Number Coded)7/c and higher: Black with white numbers plus green/yellow ground
Approvals: UL: - Type TC-ER, Oil Res I, II- Class 1 Div. 1 per NEC 501.10 (A)(2) &
501.140 (B) “Flexible Use”- Type STOOW
CSA: - c(UL) Type TC and CIC FT4 - AWM I/II A/B FT4- Type STOOW
Technical Data:
Oil Resistance:OR-03
FlameResistance:
FR-03
Motion Type:FL-01
MechanicalProperties:
MP-03
Cable Attributes, See Page 653
SKINTOP®
Strain Relief:Page 486
EPIC®
Connectors:Page 251
OLFLEX®
Tubing:Page 546
EPIC®
Pin & Sleeve:Page 462
Complete the installation with:
OLFLEX® POWER MULTI is a multi-purpose power cable with cordage, tray and Class 1 Div 1 (flexible use) approvals. The chemical resistant elastomeric jacket has superior performance vs. PVC making it ideal forhazardous industrial applications
Recommended Applications:Power cord for equipment, Paint booths, Appliances, Factory installationsand any power hook-up in the plant
Application Advantage:• UL & CSA STOOW cordage approval• UL TC-ER & CSA TC approved• Meets Class 1 Div 1 approval for
flexible use• One cable does the job of three• Durable jacket for long performance life
18 AWG (19/30) 1.00 mm2
611803611804611805611807611812611818611825
16 AWG (28/30) 1.50 mm2
611603611604611605611607611612611618611625
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
3457121825
3457121825
1925314475
113156
27364564
109163227
Nominal OuterDiameter
inches mm
PartNumber
Number ofConductors
includes ground
CopperWeightlbs/mft
Approx.Weight
lbs/mft kg/km
Nominal OuterDiameter
inches mm
9.410.112.012.816.119.321.7
10.110.912.913.818.320.924.5
627182
105176250327
7488
103132225294402
92106122156262372487
110131153196335438598
.371
.399
.471
.505
.635
.759
.855
.399
.430
.507
.544
.719
.824
.966
14 AWG (46/30) 2.50 mm2
611403611404611405
12 AWG (56/.0117) 4 mm2
611203611204611205
10 AWG (82/.0117) 6 mm2
611003611004611005
8 AWG (74/.0159) 10 mm2
610803610804
345
345
345
34
456075
75100125
110147184
184245
13.714.816.9
16.017.318.8
17.218.620.2
21.324.0
92112133
126157192
230270322
377417
137167198
188234286
342402479
561621
.541
.584
.663
.631
.681
.739
.676
.732
.796
.840
.943
Availability:
Standard put-ups are100ft, 250ft, 500ft,and 1,000ft. Bulkreels can be cut tolength.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
THE LAPP GROUP HAS ALL YOUR BETS COVERED.
SELECTING THE RIGHT CABLE FROM THE LAPPGROUP IS THE SAFEST BET YOU CAN EVER
MAKE.
Lapp Group offers a variety of cables that helpyou follow the code.
Call or visit our website to download our NFPACable Brochure.(http://www.lappusa.com/Applications-NFPAWhitePaper.htm)
THE NFPA 79 ELECTRICALCODE HAS CHANGED.
DON’T GAMBLE WITH DON’T GAMBLE WITH YOUR TIME & MONEY!YOUR TIME & MONEY!
64
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com