Oil and Gas Solution for Tough Measurement

6
Oil and Gas Solution for Tough Measurement FLUXUS ® F/G 7/80X Powerful Function and Outstanding Performance ATEX / IECEx and FM Approved for Oil & Gas Application Oil & Gas Exploration On-& Offshore FWKO and Separator In-/ Outlet Coalescers Scrubbersand Reboilers Produced Water Injection ChemicalInjection Crude Oil Refining AtmosphericDistillation Vacuum Distillation Cracking Units Coker and Visbreaker Heat Transfer Lines Gas Separation and Processing Alkylation Tank Storage Hydrocarbon Products Handling Pipeline Monitoring Allocation Terminals Chemical & Petrochemical Industry Organicand InorganicMedia Acids and Caustics PolymerizationProcesses Infrastructural Processes Natural Gas Processing

Transcript of Oil and Gas Solution for Tough Measurement

Page 1: Oil and Gas Solution for Tough Measurement

Oil and Gas Solution for Tough

MeasurementFLUXUS ® F/G 7/80X

Powerful Function and Outstanding Performance

ATEX / IECEx and FM Approved for Oil & Gas Application

Oil & Gas Exploration

On-& Offshore

FWKO and Separator In-/ OutletCoalescers

Scrubbers and Reboilers Produced Water Injection

Chemical Injection

Crude Oil RefiningAtmospheric Distillation

Vacuum Distillation Cracking Units

Coker and Visbreaker

Heat Transfer Lines

Gas Separation and

Processing Alkylation

Tank Storage

Hydrocarbon Products Handling

Pipeline Monitoring Allocation Terminals

Chemical & Petrochemical

Industry

Organic and Inorganic MediaAcids and Caustics

PolymerizationProcessesInfrastructural Processes

Natural Gas Processing

Page 2: Oil and Gas Solution for Tough Measurement

Distillation Columns (ADU / VDU)

Particularly on heavier hydrocarbons and residue lines,

conventional inline flow measurement technologies, such as DP

meters, often struggle with impulse line clogging causing opera-

tional and safety issues. FLEXIM‘s WaveInjector® measures from

the outside of the pipe wall, independent of the internal pressure

and temperature, solvingflow applications such as:

→ Crude oil heating prior to ADU

→ ADU outlets with various distillates

→ Overflash circulation

→ ADU and VDUresidues

→ LVGO outlets

→ HVGOoutlets

→ Slop oil

Moreover, with the WaveInjector® there is no need for process

interruption during installation and preventive maintenance is

not required.

Coking (DCU) and Visbreaking

Delayed coking works under extreme process conditions with the

highly viscous and particle-loaded medium tending to already

coke before reaching the drum.

For this reason, very reliable but also accurate flow rate monito-

ring at the coker feed lines is essential to prevent such prematu-

re coke formation and avoid operational safety risks.

The WaveInjector® has proven its high reliabil-ity in such extre-

me conditions again and again without showing any measure-

ment drift, without causing internal pressure drops and offering

a virtually maintenance-freesolution.

Hydrocracking (HCU)

Hydrocracking operates at high temperatures and pressu-

re ranges with highly dynamic flow rates. Such conditions

place high demands on the inline flowmeters used, such as

Vortex meters, and often require NACE-compliant material

certificates. Being mounted outside the pipe wall, the Wave-

Injector® never poses a safety risk to the process by itself.

Given this advantage, the ultrasonic measurement system

has already been put in place at many HCU loop control points

with pipe temperatures up to 400°C and pressure rates of

around 200 bar.

In addition to the safety aspect, non-intrusive ul trasonic flow

measurement is also maintenance-free and does not require any

process interruption for installation which in turn makes it a very

cost-efficientmetering solution.

For measuring hydrogen streams, FLEXIM also provides non-

intrusive ultrasonic gas flowmeter solutions eliminating the risk

for potential leaks.

Fluid Catalytic Cracking (FCC)

Flowmeters in FCC reflux lines or fractionator bottoms face the

challenge of abrasive catalyst particles in slurry causing a high

degree of wear and tear on any inline measurement systems.

FLEXIM’s clamp-on ul trasonic flowmeters are neither affected by

abrasion,nor are theya leakage risk.

Tank Storage - Hydrocarbon Product

Identificationand Tank Dewatering

With the FLUXUS® HPI meter, it is possible to combine flow me-

tering with hydrocarbon product identification. As hydrocar-

bon products can be distinguished through the ul trasonic signal,

the FLUXUS® HPI meter is the meter of choice in tank storage

applications when different hydrocarbons are successively

passing through the lines. Moreover, it is also the ideal tool for

tank dewatering applications as water / hydrocarbon cuts can

clearly be detected.

Portable Flow and Energy Surveys

Not every measurement point within a refinery needs to be

constantly monitored by a permanent meter. Thus, it is helpful

to use FLEXIM‘s range of hazardous area portable liquid and gas

flowmeters for regular surveys and check metering / verifica-

tion tasks. With the use of non-intrusive temperature probes,

FLEXIM‘s portable flowmeters also allow thermal energy

measurements for efficiency monitoring of heat exchangers or

plant wideenergy audits.

Page 3: Oil and Gas Solution for Tough Measurement

FLUXUS® F/G 7/80X

SpecificallyDesigned forDemandingEnvironments

From Oil & Gas Exploration and Production

to Petrochemical and Chemical Processing

From wellhead to refinery, the flows of crude oil, natural gas and refined products

need to be measured every stepof the way. Harsh environments with corrosiveatmospheres offshore or hot and dirty applications during crude oil refining require

tough solutions.

Also during chemical processing, liquid mediasuch as acids, caustics as well as

highlyviscous organic substancesor highlypressurised gas lines placeenormousmaterial and mechanicalstress upon wetted flow measurement technologies.

FLEXIM offers the better alternative:

→ Dual core processor, fastest response time, even for super low flow and super high flow, the performance always be perfect and unapproachable.

→ Transi t-time and noise trace based measurements, not m atter any kinds of tough application, measurement a lways be stable and reliable .

→ The measurement system can never be the cause for a potential pipe leak,cannotbe prone to clogging andis virtuallymaintenance-free.

→ It is suitable for all pipe sizes from 10 mm (3⁄8 inch) diameter upwards,with no

limitation on pipe material, wall thickness and media temperature.

→ FLEXIM‘s ul trasonic flowmeters offer exceptional reliability and accuracy even at

high and low flows due to their matched, calibrated and temperature compensa-ted transducer pairs as well as sophisticated internal signal processing.

→ With measurement from outside of the pipe wall, the system offers a long lifeti-me as well as high energy efficiency as pressure losses inside the pipe canbe

avoided.

FLEXIM’s permanentlyfixed installation and portableflowmeters for

explosive andhazardous areashave already beenproven worldwide inmany demanding applications with major operators.

Chemical Industry

- Hazardous Organic and

Inorganic Media

- Acids and Caustics- Process Gases

- Polymerisation Processes- Infrastructural Processes

Hydrocarbon ProductsHandling

- Hydocarbon Products Flow

Measurement

- Pipeline Integrity Monitoring- Allocation Terminals

- LNG Terminals- UndergroundGasStorage- Gas Distribution and

Compressor Stations

Crude Oil Refining and Gas Processing

- Distillation Columns

- Cracker and Coker Units- Petrochemical Processes

- Gas Processing

Oil & Gas Exploration On- & Offshore

- FWKO and Separator

Outlets

- Coalescers- Scrubbers and Reboilers

- Produced Water Management- Chemical Injection

Page 4: Oil and Gas Solution for Tough Measurement

Advantages:- Bi-directional flow measurement of

liquids and gases in ATEX/ IECExZone 1 and

FM Class I, Div. 1 areas

- Very cost effective: No pipe works

- No process shut-downs Virtually

maintenance-free

- Matched,paired and wetcalibratedflow transducers (traceable

certification to national standards)

- Excellent zero point stability and drift-

free

- Wide turndown ratio

- Independent ofmaterial,operating pressure, medium and

temperature, viscosity

- High toleranceto entrained

solids and gases

- Free of wear, tear and abrasion

- Not prone to clogging orcorrosion

- No pressure loss or source of

potential leaks and fugitive

emissions

The rugged FLUXUS® F/G 7/80X ultrasonic flow

meters just got stronger:

The FLUXUS® F/G 7/80X are ATEX / IECEx Zone 2 as well as FM Class I, Division 2

approved and have all the benefits of our standard FLUXUS flow meters but in acorrosion resistant Stainless Steel 316L / 1.4404 housing, ideal for any application

where the flow meter is exposed to high humidity, moisture, corrosive coastal

environments as well as offshore.

The flow meters allow for an inherently bi -directional flow measurement of

volume and mass flow rates of nearly any liquid and gaseous media - from crude oiland natural gas to refined products - and can be equipped with various outputs to be

used for a sophisticated process control.

As the ul trasonic transducers are mounted on the outside of the pipe wall, enclosedin the rugged and corrosion resistant stainless steel VARIOFIX mounting fixture, the

system does not suffer from wear, tear or clogging andcan‘t be a risk for leaks.

And with the same matched and paired transducers as well as the internal

temperature compensation (compliant to ANSI/ASME regulations), the measurement

system is drift f ree and zero stable. Moreover, as the transducers calibration data isautomatically loaded by connecting the transducers to the transmitter, set-up times

are significantly reduced.

Leveraging its exceptional dual-µP technology, the high number of measuring

cycles per second and the adaptive signal processing, the FLUXUS® F705 and G705

flow meters produce stable and reliable measuring results even under extremeenvironmental conditions.

BU705V1-1EN 2014/04Subject to change without notification

Page 5: Oil and Gas Solution for Tough Measurement

FLUXUS® F/G 7/80X

ATEX / IECEx Zone 1 and FM Class I,

Div. 1 approved liquid and gas flow

meter

Operating tempera-ture - transmitter: -30 °C to +60 °C

Physical quantities: volumetric flow rate,mass flow rate, flow velocity

Degree of protectionTransmitter (acc. toIEC / EN 60529):

IP66 (corrosion resistant coating - applicable for

usage offshore)

Flow velocity range Liquids:Gases:

0.01 to 25 m/s

0.01 to 35 m/s

Electrics Mounting: Compact and remote mounting available.

10 mm up to 6500 mm 40 mm to 2100 mm

Repeatability: 0.15%of reading*

Accuracy* Liquids:

Gases:

± 0.5% of reading,field calibration**

± 1%of reading, depend on application.

± 0.5% of reading,field calibration**

± 1% to 3% of reading, depend on application.

Technical Factors

BU

F/G

80X

V1-2

EN

2015/1

2

Su

bje

ct

toch

an

ge

with

ou

tn

otifica

tio

n

* under reference conditions and with v > 0.15 m/s* * if reference uncertainty better than < 0.2%

Cable length: Up to 300m

armored cables available on request.

Enclosure Housing: epoxy coated aluminumCF8M stainless steel

Characteristics The FLUXUS® F7/80X liquid/gas process transmitter can be connected with clamp-on, wetted transducers or integrated spool. 1,2 multi- traverses chordal design. Transit-time and noise track base measurements. Dual-μ processor; outstanding low flow and high flow performance; Excellent long- term stability and reliability. Easy to install and operate; No moving or intruding parts, no drift, no pressure loss; No maintenance; Excellent long-term stability and reliability.

Pipe Diameter RangeLiquid:Gas:

Page 6: Oil and Gas Solution for Tough Measurement

FLUXUS® F/G 7/80X

ATEX / IECEx Zone 1 and FM Class

I, Div. 1 approved liquid and gas

flow meter

Frequency: Depend on appplications

Operating pressure: 0-10MPa available.

Higher pressure on request.

Permissible content: Air bubble: >10% in volume Solids: >10% in volume

Viscosity: Up to 1000 cSt.

Technical Factors

BU

F/G

80X

V1-2

EN

2015/1

2

Su

bje

ct

toch

an

ge

with

ou

tn

otifica

tio

n

Material:Transducers:Body and Flange:

Stainless steel

Carbon steel; Low carbon steel; Stainless steel

other materials available on request.

Flange connection : ASME B16.5, up to 1500#DIN EN 1092-1, up to PN100other standards available on request.

NACE conformity: on request for NACE compliance.

Straight run: Upstream/Downstream 10/5D recommended

Hazardous AreaClassifications: ATEX / IECEx Zone 1 and FM Class I, Div. 1 areas

EnvironmentalProtection: IP66 (NEMA 6X), IP68 available

Process temperatures -40 °C to +200 °C (-200 °C to +600 °C as option) For other options please consult Flexim.

Data logger capacity: >100 000 measured values

Loggable Values: all physical quantities, totalized values and diagnostic values

Outputs/Inputs: outputs:4-20mA, frequency, reed relay, optorelay inputs: 4-20mA, PT100/PT100.

Interface: Modbus RTU, HART, RS485

Power supply: 100 to 240 VAC / 50 to 60 Hz or 20 to 32 V DC