Offaly County Council - Environmental Protection … · Fitz Scientific Offaly County Council...
Transcript of Offaly County Council - Environmental Protection … · Fitz Scientific Offaly County Council...
Offaly County Council Áras an Chontae, Charleville Road, Tullamore, Co. Offaly
Derryclure Landfill (W0029-04)
Quarter 4 Surface Water Monitoring Report
Report Date:
8th December 2015
Fitz Scientific
Unit 35A, Boyne Business Park, Drogheda, Co. Louth
Report No. 4620/M207
1 of 11
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 28-09-2016:01:47:31
Fitz Scientific Offaly County Council
Report No. 4620/M207 Derryclure Landfill – W0029-04
1.0 Scope This report deals with the 4th Quarterly sampling and analysis of surface water from the Derryclure Landfill facility located at Tullamore, Co. Offaly. Monitoring was as a result of requirements set out in Waste Licence Register No. W0029-04. Surface Water is required to be sampled at the following locations at the Derryclure Landfill facility; SW-7, SW-8, SW-9, SW-10, SW-11 and SW-12. Condition 4.2.2 of the Waste Licence sets trigger limits for BOD (25 mg/L) and Suspended Solids (60 mg/L) at surface water monitoring locations SW-7, SW-8, SW-9, SW-10, SW-11 and SW-12. 2.0 Methodology Grab samples of surface water were collected by Fitz Scientific personnel on the 23rd November 2015, and brought to the Fitz Scientific laboratory for analysis. The analytical methods used are from Standard Methods for the Examination of Water and Wastewater, 20th edition, 1998. The Certificates of Analyses (Referenced 1179/106/04–08) are attached to this Report. 3.0 Interpretation of Results SW7 is located to the south-west of the landfill, in close proximity to the landfill site entrance. It is a surface water drain located in a manhole. All parameters are within the Class A3 limit of the Surface Water Regulation. The trigger limits of 25 mg/L BOD and 60 mg/L Suspended Solids concentration as specified in Condition 4.2.2 of Waste Licence Register No. 0029-04 were not exceeded during this monitoring period. SW8 is located out of the landfill boundary. It is a stream to the west of the landfill. The trigger limit of 25 mg/L for BOD as specified in Condition 4.2.2 of Waste Licence Register No. 0029-04 was not exceeded during this monitoring period. The trigger limit of 60 mg/L for Suspended Solids was exceeded with a value of 213 mg/L. The result for COD was 48 mg/L during this sampling period and is outside the Class A3 limit of 40 mg/L. All parameters are within the Class A3 limit of the Surface Water Regulation. SW9 is located out of the landfill boundary. It is a stream to the west of the landfill. The result for Suspended Solids was 60 mg/L during this sampling period and was outside the Class A3 limit of 50 mg/L but within the trigger limit of 60 mg/L as specified in Condition 4.2.2 of Waste Licence Register No. 0029-04. The result for COD was 69 mg/L during this sampling period and is outside the Class A3 limit of 40 mg/L. All parameters are within the Class A3 limit of the Surface Water Regulation. SW10 is located out of the landfill boundary. SW10 is located out of the landfill boundary. It is a stream to the west of the landfill. The trigger limit of 25 mg/L for BOD as specified in Condition 4.2.2 of Waste Licence Register No. 0029-04 was not exceeded during this monitoring period. The trigger limit of 60 mg/L for Suspended Solids was exceeded with a value of 103 mg/L. The result for COD was 67 mg/L during this sampling period and is outside the Class A3 limit of 40 mg/L. All parameters are within the Class A3 limit of the Surface Water Regulation.
2 of 11
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 28-09-2016:01:47:31
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 28-09-2016:01:47:31
Appendix 1: Table of Results for Surface Water Monitoring Points
Parameter Units A1 A2 A3 SW7 SW8 SW9 SW10 SW11 SW12 Trigger Limits
as per W.L. 0029-04 (Applies to SW 7 – 11)
Lab Report Ref. No. 1179/ 106/06
1179/ 106/07
1179/ 106/08
1179/ 106/04
Dry 1179/ 106/05
Ammonia mg/L as N 0.16 0.17 3.11 0.495 0.036 0.048 0.022 - 0.047 -
BOD mg/L 5 5 7 <2 <2 <2 <2 - <2 25
Chloride mg/L 250 250 250 24.51 18.31 24.27 16.77 - 26.13 -
COD mg/L - - 40 5 48 69 67 - 30 -
Conductivity uscm-1 @20C
1000 1000 1000 592 630 867 708 - 720 -
Dissolved Oxygen % >60% >50% >30% 52.5 58.9 56.3 40.8 - 63.4 -
pH pH Units 5.5 - 8.5 5.5 - 9.0 5.5 - 9.0 7.5 7.4 7.3 7.3 - 7.7 -
Solids (Total Suspended)
mg/L 50 - - 7 213 60 103 - <2 60
Temperature degrees C 25 25 25 11.5 8.6 8.9 8.1 - 9.1 -
4 of 11
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 28-09-2016:01:47:31
Appendix 2: Site Monitoring Location Map
5 of 11
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 28-09-2016:01:47:31
Fitz Scientific Offaly County Council
Report No. 4620/M207 Derryclure Landfill – W0029-04
Appendix 3: Certificate of Results
6 of 11
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 28-09-2016:01:47:31
CERTIFICATE OF ANALYSIS
Unit 35,Boyne Business Park,Drogheda,Co. LouthIrelandTel:Fax:Web:email
+353 41 9845440+353 41 9846171 [email protected]
Marian Healy
Offaly Co. Co. (Derryclure Landfill)
Aras an Chontae
Charleville Road
Tullamore
Offaly
23/11/2015
23/11/2015
Lab Report Ref. No. 1179/106/08
Date of Receipt
Date Testing Commenced
Received or Collected
Condition on Receipt
Date of Report
Customer
By Fitz: Noel
Acceptable
07/12/2015Customer PO
Test Parameter SOP Analytical Technique Result Units
A copy of this certificate is available on www.fitzsci.ie
Customer Ref SW-QT-SW9
Acc.
F/S Surface WaterSample Type
23/11/2015Sampled On
Ref 2
Ref 3
mg/L as N0.048114 ColorimetryAmmonia (Surface Water) UKASmg/L<2113 ElectrometryBOD (Surface Water) UKASmg/L24.27100 ColorimetryChloride (Surface Water) UKASmg/L69107 ColorimetryCOD (Surface Water) UKAS
uscm -1@20C867112 ElectrometryConductivity (Surface Water at 20C) UKAS%56.3715 DO MeterDissolved oxygen (%)
pH Units7.3110 ElectrometrypH (Surface Water) UKASmg/L60106 Filtration/ Drying @ 104CSolids (Total Suspended)
degree C8.9715 DO MeterTemperature (On site)
Date : 07/12/2015
PVL - Parametric Value Limit as per EU (Drinking water) Regulations (SI 122 2014)
Results shall not be reproduced, except in full, without the approval of Fitz ScientificResults contained in this report relate only to the samples tested
Aoife Harmon - Technical Supervisor
Signed :
Acc. : Accredited Parameters by ISO 17025:2005
All organic results are analysed as received and all results are corrected for dry weight at 104 C
Page 1 of 1
** : The test result for this parameter may be invalid as it has exceeded the recommended holding time (BS EN ISO 5667-3:2012)
(P) : Presumptive Results
For bacterial analysis a result of 0 means none detected in volume examined
7 of 11
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 28-09-2016:01:47:31
CERTIFICATE OF ANALYSIS
Unit 35,Boyne Business Park,Drogheda,Co. LouthIrelandTel:Fax:Web:email
+353 41 9845440+353 41 9846171 [email protected]
Marian Healy
Offaly Co. Co. (Derryclure Landfill)
Aras an Chontae
Charleville Road
Tullamore
Offaly
23/11/2015
23/11/2015
Lab Report Ref. No. 1179/106/07
Date of Receipt
Date Testing Commenced
Received or Collected
Condition on Receipt
Date of Report
Customer
By Fitz: Noel
Acceptable
30/11/2015Customer PO
Test Parameter SOP Analytical Technique Result Units
A copy of this certificate is available on www.fitzsci.ie
Customer Ref SW-QT-SW8
Acc.
F/S Surface WaterSample Type
23/11/2015Sampled On
Ref 2
Ref 3
mg/L as N0.036114 ColorimetryAmmonia (Surface Water) UKASmg/L<2113 ElectrometryBOD (Surface Water) UKASmg/L18.31100 ColorimetryChloride (Surface Water) UKASmg/L48107 ColorimetryCOD (Surface Water) UKAS
uscm -1@20C630112 ElectrometryConductivity (Surface Water at 20C) UKAS%58.9715 DO MeterDissolved oxygen (%)
pH Units7.4110 ElectrometrypH (Surface Water) UKASmg/L213106 Filtration/ Drying @ 104CSolids (Total Suspended)
degree C8.6715 DO MeterTemperature (On site)
Date : 30/11/2015
PVL - Parametric Value Limit as per EU (Drinking water) Regulations (SI 122 2014)
Results shall not be reproduced, except in full, without the approval of Fitz ScientificResults contained in this report relate only to the samples tested
Aoife Harmon - Technical Supervisor
Signed :
Acc. : Accredited Parameters by ISO 17025:2005
All organic results are analysed as received and all results are corrected for dry weight at 104 C
Page 1 of 1
** : The test result for this parameter may be invalid as it has exceeded the recommended holding time (BS EN ISO 5667-3:2012)
(P) : Presumptive Results
For bacterial analysis a result of 0 means none detected in volume examined
8 of 11
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 28-09-2016:01:47:31
CERTIFICATE OF ANALYSIS
Unit 35,Boyne Business Park,Drogheda,Co. LouthIrelandTel:Fax:Web:email
+353 41 9845440+353 41 9846171 [email protected]
Marian Healy
Offaly Co. Co. (Derryclure Landfill)
Aras an Chontae
Charleville Road
Tullamore
Offaly
23/11/2015
23/11/2015
Lab Report Ref. No. 1179/106/06
Date of Receipt
Date Testing Commenced
Received or Collected
Condition on Receipt
Date of Report
Customer
By Fitz: Noel
Acceptable
30/11/2015Customer PO
Test Parameter SOP Analytical Technique Result Units
A copy of this certificate is available on www.fitzsci.ie
Customer Ref SW-QT-SW7
Acc.
F/S Surface WaterSample Type
23/11/2015Sampled On
Ref 2
Ref 3
mg/L as N0.495114 ColorimetryAmmonia (Surface Water) UKASmg/L<2113 ElectrometryBOD (Surface Water) UKASmg/L24.51100 ColorimetryChloride (Surface Water) UKASmg/L5107 ColorimetryCOD (Surface Water) UKAS
uscm -1@20C592112 ElectrometryConductivity (Surface Water at 20C) UKAS%52.5715 DO MeterDissolved oxygen (%)
pH Units7.5110 ElectrometrypH (Surface Water) UKASmg/L7106 Filtration/ Drying @ 104CSolids (Total Suspended)
degree C11.5715 DO MeterTemperature (On site)
Date : 30/11/2015
PVL - Parametric Value Limit as per EU (Drinking water) Regulations (SI 122 2014)
Results shall not be reproduced, except in full, without the approval of Fitz ScientificResults contained in this report relate only to the samples tested
Aoife Harmon - Technical Supervisor
Signed :
Acc. : Accredited Parameters by ISO 17025:2005
All organic results are analysed as received and all results are corrected for dry weight at 104 C
Page 1 of 1
** : The test result for this parameter may be invalid as it has exceeded the recommended holding time (BS EN ISO 5667-3:2012)
(P) : Presumptive Results
For bacterial analysis a result of 0 means none detected in volume examined
9 of 11
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 28-09-2016:01:47:31
CERTIFICATE OF ANALYSIS
Unit 35,Boyne Business Park,Drogheda,Co. LouthIrelandTel:Fax:Web:email
+353 41 9845440+353 41 9846171 [email protected]
Marian Healy
Offaly Co. Co. (Derryclure Landfill)
Aras an Chontae
Charleville Road
Tullamore
Offaly
23/11/2015
23/11/2015
Lab Report Ref. No. 1179/106/05
Date of Receipt
Date Testing Commenced
Received or Collected
Condition on Receipt
Date of Report
Customer
By Fitz: Noel
Acceptable
30/11/2015Customer PO
Test Parameter SOP Analytical Technique Result Units
A copy of this certificate is available on www.fitzsci.ie
Customer Ref SW-QT-SW12
Acc.
F/S Surface WaterSample Type
23/11/2015Sampled On
Ref 2
Ref 3
mg/L as N0.047114 ColorimetryAmmonia (Surface Water) UKASmg/L<2113 ElectrometryBOD (Surface Water) UKASmg/L26.13100 ColorimetryChloride (Surface Water) UKASmg/L30107 ColorimetryCOD (Surface Water) UKAS
uscm -1@20C720112 ElectrometryConductivity (Surface Water at 20C) UKAS%63.4715 DO MeterDissolved oxygen (%)
pH Units7.7110 ElectrometrypH (Surface Water) UKASmg/L<2106 Filtration/ Drying @ 104CSolids (Total Suspended)
degree C9.1715 DO MeterTemperature (On site)
Date : 30/11/2015
PVL - Parametric Value Limit as per EU (Drinking water) Regulations (SI 122 2014)
Results shall not be reproduced, except in full, without the approval of Fitz ScientificResults contained in this report relate only to the samples tested
Aoife Harmon - Technical Supervisor
Signed :
Acc. : Accredited Parameters by ISO 17025:2005
All organic results are analysed as received and all results are corrected for dry weight at 104 C
Page 1 of 1
** : The test result for this parameter may be invalid as it has exceeded the recommended holding time (BS EN ISO 5667-3:2012)
(P) : Presumptive Results
For bacterial analysis a result of 0 means none detected in volume examined
10 of 11
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 28-09-2016:01:47:31
CERTIFICATE OF ANALYSIS
Unit 35,Boyne Business Park,Drogheda,Co. LouthIrelandTel:Fax:Web:email
+353 41 9845440+353 41 9846171 [email protected]
Marian Healy
Offaly Co. Co. (Derryclure Landfill)
Aras an Chontae
Charleville Road
Tullamore
Offaly
23/11/2015
23/11/2015
Lab Report Ref. No. 1179/106/04
Date of Receipt
Date Testing Commenced
Received or Collected
Condition on Receipt
Date of Report
Customer
By Fitz: Noel
Acceptable
30/11/2015Customer PO
Test Parameter SOP Analytical Technique Result Units
A copy of this certificate is available on www.fitzsci.ie
Customer Ref SW-QT-SW10
Acc.
F/S Surface WaterSample Type
23/11/2015Sampled On
Ref 2
Ref 3
mg/L as N0.022114 ColorimetryAmmonia (Surface Water) UKASmg/L<2113 ElectrometryBOD (Surface Water) UKASmg/L16.77100 ColorimetryChloride (Surface Water) UKASmg/L67107 ColorimetryCOD (Surface Water) UKAS
uscm -1@20C708112 ElectrometryConductivity (Surface Water at 20C) UKAS%40.8715 DO MeterDissolved oxygen (%)
pH Units7.3110 ElectrometrypH (Surface Water) UKASmg/L103106 Filtration/ Drying @ 104CSolids (Total Suspended)
degree C8.1715 DO MeterTemperature (On site)
Date : 30/11/2015
PVL - Parametric Value Limit as per EU (Drinking water) Regulations (SI 122 2014)
Results shall not be reproduced, except in full, without the approval of Fitz ScientificResults contained in this report relate only to the samples tested
Aoife Harmon - Technical Supervisor
Signed :
Acc. : Accredited Parameters by ISO 17025:2005
All organic results are analysed as received and all results are corrected for dry weight at 104 C
Page 1 of 1
** : The test result for this parameter may be invalid as it has exceeded the recommended holding time (BS EN ISO 5667-3:2012)
(P) : Presumptive Results
For bacterial analysis a result of 0 means none detected in volume examined
11 of 11
For
insp
ectio
n pur
pose
s only
.
Conse
nt of
copy
right
owne
r req
uired
for a
ny ot
her u
se.
EPA Export 28-09-2016:01:47:31