    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    ODCA Cabinet TrainingDifferences between CRMA/OAKA and

    ODCA

    By Todd Betz, Mika SkarpVersion 7

  • 8/11/2019 ODCA Differences Ver1.0

    2/23

    2

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    New UltraSite EDGE BTS OutdoorCabinet - ODCA

    The existing outdoor cabinet will be replaced withthe ODCA.

    The Current Outdoor cabinet is a modular (siteassembled) product structure consisting of thefollowing:

    Cabinet core 12TRX (CRMA+TRSA)

    Outdoor Application kit (OAKA) Internal antenna feeder kit (ATCA) Cable Entry Kit (OEKA)

    All of these kits will be integrated into the ODCAcabinet.

    ODCA is a dedicated outdoor cabinet: Ordered as one sales item code: 469873A,

    ODCA The Cabinet is delivered completely assembled.

  • 8/11/2019 ODCA Differences Ver1.0

    3/23

    3

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    New UltraSite EDGE BTS OutdoorCabinet - ODCA

    New features: Preinstalled cabinet kit (OAKA) components Preinstalled internal antenna feeder kit (ATCA),

    and cable entry block (rear facing) in the roof(OEKA)

    Easier to install antenna feeder connectors atantenna box (one big nut instead of four screws)

    Major Benefits: Typical installation time up to 50% less vs.

    current due to preinstalled jumper cables andoutdoor kit components

    Comes in one boxless packaging material tobe removed from site

    Additional base plate mounting holes allowseasier access

    Schedule: Delivery start: Nov 2005

    Note: Similar product structure change will takeplace with MIDI cabinet in 1Q/2006.

  • 8/11/2019 ODCA Differences Ver1.0

    4/23

    4

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    New UltraSite EDGE BTS OutdoorCabinet - ODCA

    Completely RoHS compliant

    Uses the same cooling principle as current cabinetnumber of fans and fan type remains the same

    Power consumption and MTBF performance are identicalwith current design

    Same environmental and mechanical specifications,except:

    Cabinet weight w/o units: 147 kg ODCA 162 kg CRMA/TRSA+OAKA+ATCA+OEKA

    For weight comparison purposes, both cabinets areequally configured with ATCA and OEKA pre-installed.

    Fully compatible with all existing UltraSite units, except: Integrated Battery Back-up Unit is not supported Latest revision of the WCDMA core racking

    mechanics (WTCA) must be used.

  • 8/11/2019 ODCA Differences Ver1.0

    5/23

    5

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Current UltraSite EDGE BTS OutdoorCabinet

    + =

    Coremechanics

    020423A,CRMA+TRSA

    OutdoorApplication Kit

    467853A, OAKA

    UltraSite EDGE BTSOutdoor Cabinet

  • 8/11/2019 ODCA Differences Ver1.0

    6/23

    6

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Differences between CRMA/OAKA andODCA

    At first glance, bothcabinets look alike.

    CRMA/OAKA ODCA

  • 8/11/2019 ODCA Differences Ver1.0

    7/237 NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Differences between CRMA/OAKA andODCA

    The first difference is the amount of boxes received.CRMA + OAKA are shipped in 2 large, pallet boxes (see photos below).Within the OAKA there are 17 smaller boxes with bags (left photo). The ATCA

    and OEKA are shipped separately in 2 additional boxes w/ bags.

    Total boxes = 2 large boxes w/ pallets, and 19 smaller boxes w/ bags.

    CRMAOAKA

  • 8/11/2019 ODCA Differences Ver1.0

    8/238 NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Differences between CRMA/OAKA andODCA

    ODCA, boxed

    The ODCA has all the items from the previous slide installed to one item.

    Total box count reduction is 20 plus bags.

    ODCA, unboxed

  • 8/11/2019 ODCA Differences Ver1.0

    9/239

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Differences between CRMA/OAKA andODCA

    ODCA

    Different Vent designPlastic vs a metal louverDesign (like MIDI).

    CRMA/ OAKA

    Once you get theCRMA/OAKA assembledThe first different itemis the front vents on theDoor.

  • 8/11/2019 ODCA Differences Ver1.0

    10/2310

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Differences between CRMA/OAKA andODCA

    CRMA ODCA

    Access to the optionalfront mounting boltsDifferent base plate

    The mounting and plinths are a major change.

    The ODCA plinth is attached to the cabinet and cannot be removed.

  • 8/11/2019 ODCA Differences Ver1.0

    11/2311

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Differences between CRMA/OAKA andODCA

    CRMAODCA

    Access to optional rear

    mounting bolts

    Optional mounting locations in the rearof the cabinet are accessible fromoutside.

  • 8/11/2019 ODCA Differences Ver1.0

    12/2312

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Differences between CRMA/OAKA andODCA

    ODCA

    The preferred method and Zone 4 required Earthquake mounting isnow located inside of the cabinet in the four locations shown.No other mounting is recommended for Earthquake rated zones.

    Mountingpoints

  • 8/11/2019 ODCA Differences Ver1.0

    13/2313

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Differences between CRMA/OAKA andODCA

    ODCACRMA/OAKA/OEKA

    The entry block will be preinstalled facing the rear of the cabinet.

    The possible new entry block (right photo) has 6 less cable entryholes. This is to cut down the assembly time. OAKA has 12 gasketparts, ODCA will have only 6 which is easier to assemble.

  • 8/11/2019 ODCA Differences Ver1.0

    14/2314

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Differences between CRMA/OAKA andODCA

    CRMA ODCA

    Double EMC net vs a Single EMC net design

  • 8/11/2019 ODCA Differences Ver1.0

    15/23

    15

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Differences between CRMA/OAKA andODCA

    ODCA

    Several parts are preinstalled in the cabinet to cut installation time

    Door Switch

  • 8/11/2019 ODCA Differences Ver1.0

    16/23

  • 8/11/2019 ODCA Differences Ver1.0

    17/23

    17

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    The bulkhead connectors on the ATCA cables are now mounted using

    a large nut w/ D shaped connector instead of 4, M3 screws.

    Old style Connector, 4small screws

    New, D shaped connector,one washer+nut

    Differences between CRMA/OAKA andODCA

  • 8/11/2019 ODCA Differences Ver1.0

    18/23

    18

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Differences between CRMA/OAKA andODCA

    ODCA

    Pre-installed Antenna cablesare labeled with tapeso they can be easilymatched in the top of thecabinet.

    Red

    Green

    Blue

  • 8/11/2019 ODCA Differences Ver1.0

    19/23

    19

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Differences between CRMA/OAKA andODCAODCA

    The pre-assembly includes the Baseband (qty 5) and DTRU Dummy(qty3) units, and TRX connector covers (qty 11).

  • 8/11/2019 ODCA Differences Ver1.0

    20/23

  • 8/11/2019 ODCA Differences Ver1.0

    21/23

    21

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    Door Grounding Cable is now longer and round, not flat cable

    CRMA/OAKA ODCA

    Differences between CRMA/OAKA andODCA

  • 8/11/2019 ODCA Differences Ver1.0

    22/23

    22

    NOKIA ODCA.PPT / 18-04-2005 / MSk Company Confidential

    The IBBU and Triple Mode Power cables (J1) removed from the

    busbar. Adapter cables added to the WTCA unit provide the powerconnection for a Triple Mode system.

    CRMA ODCA

    J1

    J1 removed

    Differences between CRMA/OAKA andODCA

  • 8/11/2019 ODCA Differences Ver1.0

    23/23