OCULUS SDI 4 / BIOM 4
-
Upload
duongduong -
Category
Documents
-
view
282 -
download
3
Transcript of OCULUS SDI 4 / BIOM 4
We focus on progress
OCULUS SDI 4 / BIOM 4
WideAngleObservation
OCULUSBIOM4BinocularIndirectOphthalmoMicroscopefornoncontactwideangleobservation
> TheBIOM4seriescontinuouslyincorporatestheprincipleofindirectophthalmoscopyintheoperatingmicroscope.
> ThelegendarysuccessiscontinuedwiththemechanicallyfocusedversionBIOM4m.
> TheBIOM4cwithmotorizedfocuscompletesthecurrentrangeandoffersmaximumcomfortinuse.
> Improveyourpossibilities,upgradeyourmicroscope!
The easy handling of the BIOM 4 persuades more and more surgeons. While observing the vitreous and the fundus, the BIOM 4 is aligned coaxially with the operating micro-scope. During extraocular phases of surgery, it is swung aside out of the observation beam while the inverting action of the SDI is neu-tralized manually, by foot switch or automatically, if the SDI 4c / BIOM 4c version is used. All sterilizable parts of the BIOM system are steam autoclavable following the latest recommendations.
Optimizedlensstability
As a result of the new stainless steel lens holder, the lens position above the cornea is stabilized.
Due to the shape of the lens receptacle and the small size of the lens frame, space consumption in the operating field is minimized.
OCULUSBIOM4Usetheoriginal,trustonmorethan20yearsofexperienceandknowhow.
BIOM4m(mechanicallyfocused)Deliversperfectview,independentfromthepatient’srefraction
Foruser’scomfortaswellaspatient’sbenefit,itenables:
Upto125degreeofnon-contactobservationofthefundus Highmagnificationofthemaculararea Vitreoussurgerythroughsmallpupils Stablepositionovertheeye Goodfundusobservationduringuseofvitreoussubstitutes Nocontact–nocornealstress Fastandeasyadaptionontothemicroscope ImprovedlensalignmentthroughmagneticsupportofBIOM4
andcorrespondingadapterplate Newenhancedlensholder Choiceofdifferentsteamautoclavablelenses
Continuityandcompatibility
Stay connected: BIOM 4 parts are interchangeable with most accessories of the former BIOM 3 version.
> BIOM4msetup
OCULUSBIOM4
> Intelligentactivationof theSDI4c
BIOM4c(withmotorizedfocus)
IncludingtheimprovementsoftheBIOM4m,thelatestversion,theBIOM4coffersadditionallythecomfortofmotorizedfocusingoftheBIOMimage.Itincorporatestheintelligentandautomaticcontrolofthecorrespondinginverter,theSDI4c.
Thesecret
A steam autoclavable micro switch for control of the SDI 4c guarantees comfort at its best. The activation of the inverter function is ensured as long as the position of the BIOM 4c requires it. Certainly the SDI can be controlled independently.
> SDI4m
> SDI4e
> SDI4c
OCULUSSDI4StereoscopicDiagonalInverter
> Cutting-edgetechnologyinastunningdesign
MinimizeddimensionsofallinvertertypesoftheSDI4productlineallowintegrationinmostsurgicalmicroscopesinthemarket.Allinvertersareusinghightransmissionglassoptics,speciallycoated.
Manuallyoperatedinversion
Thebasicversion,easytomountonnearlyeverymicro-scopetypeintheophthalmologicaldiscipline.Novoltagesupplyorcablesrequired.Theinvertingfunctioniscontrol-ledviasterilecoveredcontrolknobonthefrontside.
Motorizedinversion
TheSDI4ecanbeactivatedbyanoptionalfootswitch.Somemicroscopetypesalsooffertheintegrationoftheswitchcontrolintothefootpedalofthemicroscope.
AutomaticinvertercontrolledbythepositionoftheBIOM4c
Themostcomfortableversion.ThisSDIisrequiredtocontrolthemotorizedfocusoftheBIOM4c.ItalsocanbeusedtogetherwithanyotherversionoftheBIOM.UsedtogetherwithBIOM4c,theSDI4cisactivateddependingonthepositionoftheBIOM4c.
> Smallerthanever–reallyslim
> Forergonomicsinuse
Ausefulaccessory–sterilizablecableguide
> SpeciallydesignedfortheBIOM4c,thissteam autoclavableguidancedirectstheconnectingcable
> ConnectorsonbothsidesoftheSDI4cenable comfortablehandlingoftheBIOM4c
> Customizedsterilizationtrayfor allsteamautoclavableBIOMparts.
Widevarietyoflenses
Max. observation angle approx. 70° approx. 60° approx. 90° approx. 120° approx. 60° - 125°
Outer diameter 12 mm 19 mm 19 mm 19 mm 21 mm
Steam autoclavable with max. temperature
134° C 134° C 134° C 134° C 134° C
Surface / material amorphous carbon coating
amorphous carbon coating
amorphous carbon coating
amorphous carbon coating
quartz glass
Features for easy maneuverability of instruments in small and deep seated or infants‘ eye
best resolution of small structures, high magnification of the micro-scope possible
intermediate field
most common BIOM lens, first choice of advanced users
high resolution combined with wide field of view
Min
iWid
eFi
eld
Lens
Wid
eFi
eld
Enha
nced
Len
s
Wid
eFi
eld
Hig
hD
efini
tion
Lens
90
DL
ens
HiR
esM
acul
aLe
ns
Spec
ifica
tion,
acc
esso
ries
and
desi
gna
res
ubje
ctto
cha
nge
with
outn
otifi
catio
nan
dm
ayv
ary
depe
ndin
gon
regi
on.
42/0
910/
e/Fr
AdaptationsOCULUSSDI4/BIOM4SDI 4 / BIOM 4 adaptations are currently available for the following microscope types:Kaps SOM
Leica M500/M501,M620,M650,M690,M841,M820,M844
Möller Ophtamic900,Hi-R900,EOS900,Allegra900
Takagi OM18
Topcon OMS110,OMS600,OMS610,OMS650,OMS710,OMS800Standard,OMS800Pro,OMS850Standard,OMS850Pro
Zeiss OPMIVISU150/160,VISU200/210,Lumera700,LumeraT,Lumerai,OPMICSwithRetrolux1/3/CSorwithRetroskop1/2/CS,OPMIMDI/MDO/MDU,OPMI1/6
OCULUS Optikgeräte GmbHPostfach • 35549 Wetzlar • GERMANY Tel. +49-641-2005-0 • Fax +49-641-2005-295E-Mail: [email protected] • www.oculus.de
OCULUS is certified by TÜV according toDIN EN ISO 13485/DIN EN ISO 9001
WWW.OCULUS.DE
inaccordancewithMedicalDeviceDirective2007/47/EG
Fitstomostsurgicalmicroscopes
Specific:AllSDI4c/BIOM4cfunctionscanbecontrolledwiththe16functionsfootpedaloftheLeicaM844/M820surgicalmicroscope.