Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL:...

13
Ocular Aberrations and Quality of Vision with Aspheric Single- Piece and Spherical Multi-Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd the author of this poster have received travel expense reimbursement from AMO Company

Transcript of Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL:...

Page 1: Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.

Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi-

Piece IOL: Contra lateral Comparative Study

Ahmed Assaf MD, FRCSEd

the author of this poster have received travel expense reimbursement from AMO Company

Page 2: Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.

Intraocular Lenses (IOLs)

• Spherical aberration (SA) and coma are the commonest HOAs to affect quality of vision

• Aspheric IOLs with negative SA aim to balance the positive corneal SA, thus reducing the amount of total ocular SA with respect to conventional spherical IOLs

Page 3: Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.

Spherical 3-piece (Sensar AR40e) IOL

Page 4: Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.

Aspheric (Tecnis 1-P, Tecnis ZCB00) IOL

OPTIC of the lens has negative spherical aberration of 0.27µm to compensate for average corneal positive spherical aberration

Page 5: Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.

Purpose of the Study

• To test visual outcomes and higher ocular aberrations of aspheric (Tecnis 1-P) IOL against spherical (Sensar AR40e™) biconvex multi-piece IOL.

• Both lenses are made of hydrophobic acrylic and by the same company (AMO, Abbott Medical Optics, Santa Ana, CA)

Page 6: Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.

P=0.81P<0.001

Pre OperativePre Operative Post OperativePost Operative

Mic

ron

Mic

ron

0.28±0.08

0.29±0.09

0.006±0.03

0.42±0.11

VISX ™ WaveScan Wavefront System VISX ™ WaveScan Wavefront System

SphericalSpherical(Sensar)(Sensar)

AsphericAspheric(Tecnis 1-P)(Tecnis 1-P)

SphericalSpherical(Sensar)(Sensar)

OCULUS Optikgeräte GmbH, Easygraph

AsphericAspheric(Tecnis 1-P)(Tecnis 1-P)

n=28

Spherical Aberration

Page 7: Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.

P=0.88

P=0.76

Pre OperativePre Operative Post OperativePost Operative

Mic

ron

Mic

ron

0.167±0.09

0.158±0.0850.154

±0.0710.151±0.071

VISX ™ WaveScan Wavefront System VISX ™ WaveScan Wavefront System

SphericalSpherical(Sensar)(Sensar)

AsphericAspheric(Tecnis 1-P)(Tecnis 1-P)

SphericalSpherical(Sensar)(Sensar)

OCULUS Optikgeräte GmbH, Easygraph

AsphericAspheric(Tecnis 1-P)(Tecnis 1-P)

Coma

Page 8: Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.

P=0.38

Pre OperativePre Operative Post OperativePost Operative

Mic

ron

Mic

ron

0.185 ± 0.12 0.162

± 0.12

0.157 ± 0.13

0.145 ± 0.12

VISX ™ WaveScan Wavefront System VISX ™ WaveScan Wavefront System

SphericalSpherical(Sensar)(Sensar)

AsphericAspheric(Tecnis 1-P)(Tecnis 1-P)

SphericalSpherical(Sensar)(Sensar)

OCULUS Optikgeräte GmbH, Easygraph

AsphericAspheric(Tecnis 1-P)(Tecnis 1-P)

P=0.47

Trefoil

Page 9: Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.

Aspheric IOL (mean±SD) Spherical IOL (mean±SD) P

Sphere (D) -0.01D±0.60 -0.06D±0.67 P=0.67

Cylinder (D) -0.57D±0.30 -0.55D±0.32 P=0.84

Spherical Equivalent (D) -0.30D±0.66 -0.34D±0.74 P=0.69

LogMAR BCVA 0.046±0.01 0.053±0.09 P=0.78

Page 10: Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.

Log

Cont

rast

Sen

sitiv

ity (C

S)Lo

g Co

ntra

st S

ensi

tivity

(CS)

Cycles per Degree (CPD)Cycles per Degree (CPD)

n=28 VectorVisionTM 1000E Chart

85cd/m2

6 wks postop.P=0.043

Page 11: Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.

Log

Cont

rast

Sen

sitiv

ity (C

S)Lo

g Co

ntra

st S

ensi

tivity

(CS)

Cycles per Degree (CPD)Cycles per Degree (CPD)

P<0.001

P<0.001

P<0.001

P<0.001

n=28 VectorVisionTM 1000E Chart

6cd/m2

6 wks postop.

Page 12: Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.

Conclusion

Aspheric (Tecnis 1-P) IOL significantly reduce ocular spherical aberration. This is reflected as improved quality of vision mainly in mesopic conditions.

Page 13: Ocular Aberrations and Quality of Vision with Aspheric Single-Piece and Spherical Multi- Piece IOL: Contra lateral Comparative Study Ahmed Assaf MD, FRCSEd.

No significant differences regards ocular coma and trefoil of aspheric single piece IOL compared to spherical multi-piece IOL.

Thank You

Conclusion