OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

download OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

of 27

Transcript of OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    1/27

    Overview

    1

    Issue: 03Date: 2014-11-05

    This document guides you through a time-saving process for installing a storage system. For more information, see

    the OceanStor S5500T Storage System V200R002C20 Installation Guide.

    a

    Copyright Huawei Technologies Co., Ltd. 2014All rights reserved.

    Introduction to the OceanStor T Series

    Before You Start

    OceanStor S5500TStorage SystemV200R002C20Quick Installation Guide

    HUAWEI OceanStor T series storage systems are innovative mid-range and high-end offerings that are ready to

    meet your current and future storage requirements. They are designed to provide medium- and large-scale

    enterprises with improved storage performance, efficiency, security, scalability, and manageability.

    Where to get helpb

    Feedbackc

    You can obtain the product documentation from the documentation CD-ROM delivered with the product or from

    http://enterprise.huawei.com. You can also register for a Huawei support account at this website to browse and

    download valuable information and sign up for product updates.

    Your feedback is important to us. If you have any comments about this document, please submit them to us on

    the Huawei Enterprise website.

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    2/27

    Installation Process

    Safety Information

    Do not operate devices or handle cables on a stormy day.

    To avoid eye injuries, do not look into the optical outlets without eye protection.

    Arrange for at least three persons to carry and install a fully configured enclosure to avoidpersonal injury or device damage.

    Do not wear an ESD wrist strap during power-on to avoid electric shocks.

    Scenario 1 Wearing an ESD wrist strap whose

    ground terminal is a plugScenario 2 Wearing an ESD wrist strap whose

    ground terminal is a metal clip

    Initializing the Storage System

    Checking installation tools

    Checking circuit breakers

    Checking components

    A generic viewof cable connections

    Connecting ground cables

    Connecting enclosures

    Connecting the storage systemto an application server

    Connecting to the maintenanceterminal

    Connecting power cables

    Checking device installation

    Checking cable connections

    Switching on externalpower supplies

    Pressing the power buttonon either controller

    Checking status indicatorson the enclosures

    Installing front panels

    Installation Preparations

    Installing

    Devices

    Connecting Cables

    Powering On the

    Storage System

    Checking

    Hardware Installation(Optional) Installing Host Software

    2

    Pressing the power buttonon either file engine node

    Connecting heartbeatcables for file engine nodes

    Connecting file engine nodesto controller enclosures

    Planning device installation positions

    Removing filler panelsDetermining device installationpositions using installation templates

    Installing guide rails

    Installing the controller enclosureand disk enclosures into the cabinet

    Installing filler panels

    Installing a cable manager

    Installing a disk module

    Connecting controllers

    CAUTION

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    3/27

    Checking installation tools

    c Checking components

    Checking circuit breakersba

    1 Installation Preparations

    The following installation tools are required:Phillips screwdriver (M3 to M6)Flat-head screwdriver (M3 to M6)Diagonal pliersFloating nut mounting bar

    To protect devices connected to the storage system fromunexpected power-off caused by a power failure, thecurrent of the AC power circuit breaker is 16 A.

    3

    NOTE Data switches are optional for controller expansion. All contents involving data switches are optional. 2 U controller enclosures support two types of disks, 12-slot 3.5-inch disks and 24-slot 2.5-inch disks. The Packing List contains all materials required by the installation. The bag containing the Packing List

    isattached to the outside of the carton.

    mini SAS HD cable

    Adjustableguide rails

    Floating nutand M6 screw

    Multi-mode optical

    fiber cableMini SAS cable Network cable

    Installation template(for 2 U devices)

    Ground cable

    Installation template(for 4 U devices)

    Disk enclosure (4 U)

    Controller enclosure (2 U)

    File engine (4 U)

    Cable manager

    Mini SAS HD to

    mini SAS cable

    High-density disk enclosure (4 U)

    Bearing guide rails

    Disk enclosure (2 U)

    Data switch (1 U)

    Front panel of a 2 Ucontroller enclosure

    Front panel of a 4 Udisk enclosure

    AOC cable

    NOTICE

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    4/27

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    5/27

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    6/27

    Installing adjustable guide railsd

    Scenario 1

    Attaching adjustable guide rails for a 1 U device

    The adjustable guide rails are 600 mm (23.62 in.) to 900 mm (35.43 in.) long. They are designed to fit into

    cabinets with depth ranging from 800 mm (31.50 in.) to 1200 mm (47.24 in.).

    The adjustable guide rails are preconfigured with positioning pins applicable to square holes only. For

    round holes, replace the positioning pins.

    Two paired adjustable guide rails must be positioned exactly parallel to one another.

    6

    (1)

    (2)

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    7/277

    Front

    Rear

    Scenario 3

    Attaching adjustable guide rails

    for a 4 U device

    Front

    RearScenario 2

    Attaching adjustable guide rails

    for a 2 U device

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    8/278

    Front

    Rear

    Scenario 4 Installing bearing guide rails for a high-density disk enclosure

    Cable tie

    Pull out an

    inner rail.

    Outer rail

    Cable tie

    (1)

    (2)

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    9/279

    Scenario 2 Installing a high-density disk enclosure

    2e Installing storage devices into the cabinet

    Scenario 1 Installing a controller enclosure, an

    ordinary disk enclosure and a file engine.

    To avoid device damage, do not stack any

    components but install them onto guide rails.

    Install a disk enclosure and a file engine onto

    the guide rails using the same method asinstalling the controller enclosure.

    (1) Install the inner rail.

    (4) Installing the system enclosure.

    (2) Mount the high-density disk enclosure.

    (3) Installing a cover.

    NOTICE

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    10/2710

    2f

    Installing a cable manager

    Cable managers are used for housing cables of high-density disk enclosure. Each high-density disk enclosure

    has one cable manager.

    (1) Insert the cable manager into the ball bearing guide rails and the high-density disk enclosure.

    (2) Use a Phillips screwdriver to fasten M6 screws to secure the cable manager.

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    11/27

    2h

    Installing filler panels

    11

    2g

    Installing a Disk Module

    (1)

    (2)

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    12/27

    3a

    A generic view of cable connections

    3 Connecting Cables

    12

    Maintenanceterminal Application

    server

    Diskenclosure

    Controllerenclosure 0

    Groundcable

    Externalpower

    Controllerenclosure 1

    Data switch

    Scenario 1

    Cable connection in the four-controller scenario

    Externalpower

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    13/27

    Maintenance

    terminal

    Application

    server

    External

    power

    Disk

    enclosure

    Controller

    enclosure

    Ground

    cable

    13

    Disk

    enclosure

    External

    power

    File engine

    LAN LAN

    Scenario 2

    Cable connection in the file engine scenario

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    14/2714

    3b Connecting ground cables

    3c

    Connecting controllers

    Data switch 1

    Data switch 0

    Controllerenclosure 0

    Controllerenclosure 1

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    15/2715

    3d

    Connecting heartbeat cables for file engine nodes

    File engine

    Scenario 1 Two file engine nodes

    Scenario 2 Four file engine nodes

    Ethernet switch

    Ethernet switch

    File engine

    File engine

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    16/2716

    3e

    Connecting file engine nodes to controller enclosures

    File engine

    Controllerenclosure

    Scenario 1

    Two file

    engine nodes

    Scenario 2

    Four file

    engine nodes

    File engine

    File engine

    Controllerenclosure

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    17/27

    3f Connecting enclosures

    Controller A

    Controller B

    Disk

    enclosure 2

    Disk

    enclosure 1

    Controller

    enclosure

    Expansionmodule A

    Expansionmodule B

    17

    Scenario 1 Connecting ordinary disk enclosures

    Connect expansion ports on the controller and disk enclosures to PRI ports on disk enclosures.

    Expansion ports on controller A must connect to PRI ports on expansion module A of the disk enclosure,

    whereas expansion ports on controller B must connect to PRI ports on expansion module B of the disk

    enclosure.

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    18/27

    Scenario 2 Connecting high-density disk enclosures

    18

    Connect two high-density disk enclosures using mini SAS HD cables. Connect a controller enclosure to a

    high-density disk enclosure using mini SAS HD to mini SAS cables. The cables must be naturally bent, and a

    minimum of 97 mm clearance must be reserved in front of each enclosure for winding cables.

    Note that ordinary disk enclosures and high-density disk enclosures cannot be simultaneously connected to a

    SAS interface module.

    High-densitydisk enclosure 2

    Controller

    enclosure

    High-densitydisk enclosure 1

    Controller A

    Controller B

    Expansionmodule A

    Expansionmodule B

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    19/27

    3g

    Connecting the storage system to an application server

    Scenario 1 Directly connecting host ports to the application server

    Application

    server

    Application

    server

    Controller

    enclosure

    Controller

    enclosure

    The controller enclosure can connect to application servers through 1 Gbit/s iSCSI, 10 Gbit/s TOE, 10 Gbit/s

    FCoE, 8 Gbit/s FC, and 16Gbit/s FC host ports.

    iSCSI cable connection

    Optical fiber cable connection

    19

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    20/27

    Scenario 2 Connecting host ports to the application server through switches

    iSCSI cable connection

    Optical fiber cable connection

    Application

    server

    Ethernet

    switch

    Ethernet

    switch

    Controller

    enclosure

    Application

    server

    Controller

    enclosure

    Fibre Channel

    switch

    Fibre Channelswitch

    20

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    21/27

    Scenario 3 The host port on the file engine is connected to the service network

    21

    Application server

    File engine

    LAN (Fiber Channel) LAN (Ethernet)

    3h

    Connecting to the maintenance terminal

    LAN

    Application server Application server Application server

    After connecting a serial port on the storage system to the maintenance terminal through a serial cable,you can then manage and maintain the storage system from the maintenance terminal.

    During initial configuration, set an IP address for the management network port through the serial port.

    Maintenance

    terminal

    File engine

    Controllerenclosure

    Scenario 1

    Controller enclosure and file engine connecting

    a maintenance terminal

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    22/27

    3i Connecting power cables

    22

    Scenario 2

    Four controllers connecting to a maintenance terminal

    Controllerenclosure 0

    Controllerenclosure 1

    Data switch 0

    Data switch 1

    Maintenanceterminal

    Maintenanceterminal

    Maintenanceterminal

    Maintenanceterminal

    Ethernet switch

    AC devices can connect only to AC power supplies. To ensure a high availability of the storage system and avoid

    unexpected power failures, connect the storage system to two routes of power supplies on either side or both sides.

    NOTICE

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    23/27

    Complete view of the AC power cables

    Controller

    enclosure

    Disk

    enclosure

    23

    External

    power

    File

    engine

    External

    power

    Data switch

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    24/27

    Checking cable connections

    4a Checking device installation

    4b

    Check Item Normal Abnormal

    Ground cableAOC cableOptical fiber cableMini SAS cableMini SAS HD cable

    Mini SAS HD to miniSAS cableNetwork cableSerial cable

    The cable is fully inserted and secured. The cable is loose or disconnected.

    AC power cable

    The AC power cables for each

    controller enclosure or disk enclosure

    are connected to two separate power

    supplies for redundancy.

    The AC power cables are secured

    with plastic buckles.

    The AC power cables for each

    controller enclosure or disk enclosure

    are connected to the same power

    supply.

    The AC power cables are not secured

    with plastic buckles.

    4 Checking Hardware Installation

    Check Item Normal Abnormal

    Controller enclosure

    The device sits stably on the guide

    rails without displacement.

    Screws are properly secured.

    The device slants or cannot be detected.

    Screws are loose or have fallen off.

    Disk enclosure

    File engine

    Data switch

    The power-on process takes five to ten minutes. The system is completely powered on until the power

    indicator of controller enclosure does not blink continually.

    To avoid electric shocks, do not wear an ESD wrist strap when the storage system is powering on.

    Do not adjust mini SAS cable connections between enclosures after power-on. Otherwise the storage

    system may become abnormal. For a four-controller storage system, power on controller enclosure 0 and then controller enclosure 1

    immediately.

    5 Powering On the Storage System

    Follow the correct power-on sequence of the storage system: switch on external power supplies press the

    power button on either controller module switch on the Ethernet or Fibre Channel switch press the power

    buttons on the file engine in sequence and check the indictor status switch on the application servers.

    Follow the correct power-off sequence of the storage system: stop host services power off file engine nodes

    in sequence by using the management software and wait until all indicators are off simultaneously press and

    hold down the power buttons on both controller modules until the system is completely powered off (five

    seconds) disconnect the controller enclosure and the disk enclosures from their power supplies.

    5a

    Switching on external power supplies

    Switch on external power supplies in the following sequence:

    disk enclosures controller enclosure switches (for a SAN) file engine application server.

    24

    NOTICE

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    25/27

    5b

    Pressing the power button on either controller

    5d Checking status indicators on the enclosures

    After you have powered on a disk enclosure or the controller enclosure, check that all disks are

    working correctly (no alarm/location indicator is steady red).

    Power indicator of the controllerenclosure: steady green

    Disk alarm/locationindicator: off

    Controller enclosure

    front view

    Controller enclosure

    Scenario 1 Turn on the switches of the power

    distribution boxScenario 2 Turn on the switch of the PDU

    Front

    Front

    Rear

    Rear

    25

    Pressing the power button on either engine nodec

    File engine

    NOTICE

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    26/2726

    Alarm indicator of the clusteredNAS engine enclosure: off

    Power indicator of theenclosure: steady green

    File engine

    Power indicator of the disk

    enclosure: steady green

    Alarm indicator of thedisk enclosure: off

    Alarm/Location indicatorof the disk enclosure: off

    Diskenclosure

    For details and rectification suggestions on the indicators, refer to theOceanStor

    S2600T&S5500T&S5600T&S5800T&S6800T Storage System V200R002C20 Quick Maintenance Guide.

    Controller alarmindicator: off

    Controller enclosure

    rear view

    Alarm indicator of the high-density enclosure: off

    Power indicator of the high-density enclosure: steady green

    High-density

    disk enclosure

    Data switchPower indicator of the dataswitch: steady green

    Alarm indicator of thedata switch: off

  • 8/9/2019 OceanStor S5500T Storage System V200R002C20 Quick Installation Guide 03

    27/27

    Install the following host software programs on the application server:

    1. Initiator, an optional program for iSCSI host ports. For details about installing the Initiator program, refer to

    the OceanStor S2600T Storage System V200R002C20 Installation Guide.

    2. ReplicationDirector. For details about installing the ReplicationDirector, refer to the OceanStor

    ReplicationDirector User Guide.

    3. UltraPath, a multipathing program. For details about installing the UltraPath, refer to the OceanStor

    UltraPath for Windows User Guide, OceanStor UltraPath for Linux User Guide, OceanStor UltraPath for

    Solaris User Guide, or OceanStor UltraPath for AIX User Guide.

    7 (Optional) Installing Host Software

    Contacting Huawei Technical Support

    For details about initializing the storage system, refer to the OceanStor S2600T Storage System

    V200R002C20 Installation Guide.

    The default user name and password of the storage system are adminandAdmin@storagerespectively.

    You are advised to change the default password immediately after you have logged in to the storage

    system for the first time and periodically change your password in the future. This reduces the password

    leakage risks. For details about how to modify the password, see OceanStor

    S2600T&S5500T&S5600T&S5800T&S6800T Storage System V200R002C20 Maintenance Guide.

    6 Initializing the Storage SystemAfter you have powered on the storage system, complete the following initialization steps:

    1. Change the IP address of the management network port using the command-line interface (CLI). Before

    doing this, connect the serial port on the controller enclosure to the maintenance terminal.

    2. Log in to the OceanStor DeviceManager on the maintenance terminal.3. On the DeviceManager, follow the Initial Configuration wizardto change the basic information,

    configure the device time, disk domain, alarm notification, and import license files. If you do not perform

    the initial configuration as prompted, follow-up configuration and use of services will be affected.

    Huawei customer service center

    Address: Huawei Industrial Base, Bantian, Longgang, Shenzhen 518129, People's Republic of China

    Website: http://enterprise.huawei.com

    Local Huawei technical support personnel

    Obtain contact information for local Huawei offices at http://support.huawei.com/enterprise/.

    Scenario 2 Installing the front panel for a 4 U deviceScenario 1 Installing the front panel for a 2 U device

    5e

    Installing front panels

    Obtain the documentation for the ReplicationDirector and UltraPath from the delivery-attached CD-ROM.After installing the device, you can log in to http://support.huawei.com/enterprise/, choose Support > Product

    Support > IT > Storage > Disk Storage, and select the corresponding product modelto obtain theAcceptance

    Test Guide.