To: TSSA From: Renzo Pupulin Company: Ashcroft Inc. Phone: 416 - 747- 2345 Fax: 416 - 231-6183 Fax: 416 - 401- 6789 Pages: 6 Location: Toronto Our File: ANR-1444 Date: December 7, 2009 Your File: 178560 Subject: Request for Design Registration Dear Ms. Francis, CSA has reviewed the documentation submitted by TSSA on behalf of Ashcroft Inc . These fittings have been registered by CSA for the Province of Québec. In accordance with an agreement between CSA, the Provinces of Québec, Manitoba and Saskatchewan, this registration is recognized by both Manitoba and Saskatchewan, (see copies of attachments), and these fittings are acceptable for use in these Provinces. A copy of the stamped Statutory Declaration is attached with the prefix CSA per the agreement. The CRN is CSA-0F12994.56ADD1. The cost for this service is $ 760.00 plus GST. A copy of the Statutory Declaration with an original stamp affixed will be forwarded to you along with our invoice by regular mail. Yours truly Renzo Pupulin [email protected] Project Group Manager HVAC CSA International <http://www.csa-international.org/>

Transcript of o: TSSA From: Renzo Pupulin - ashcroft.com · [J do solemnly declare that 'the fittings listed...

To: TSSA From: Renzo Pupulin

Company: Ashcroft Inc. Phone: 416 - 747- 2345

Fax: 416 - 231-6183 Fax: 416 - 401- 6789

Pages: 6 Location: Toronto

Our File: ANR-1444 Date: December 7, 2009 Your File: 178560 Subject: Request for Design Registration

Dear Ms. Francis, CSA has reviewed the documentation submitted by TSSA on behalf of Ashcroft Inc . These fittings have been registered by CSA for the Province of Québec. In accordance with an agreement between CSA, the Provinces of Québec, Manitoba and Saskatchewan, this registration is recognized by both Manitoba and Saskatchewan, (see copies of attachments), and these fittings are acceptable for use in these Provinces. A copy of the stamped Statutory Declaration is attached with the prefix CSA per the agreement. The CRN is CSA-0F12994.56ADD1. The cost for this service is $ 760.00 plus GST. A copy of the Statutory Declaration with an original stamp affixed will be forwarded to you along with our invoice by regular mail. Yours truly Renzo Pupulin [email protected] Project Group Manager HVAC CSA International <http://www.csa-international.org/>

.,. f

.) ~

TECHNICAL STANDARDS &

SAFETY AUTHORITY 14th Floor, Centre Tower 3300 Bloor Street West Toronto, Ontario Canada M8X 2X4

~ASHCROFT

See Attached Summary MAWP-02

ST A TUTORY DECLARAtION Registration of Fittings

I, Robert D Thomas. VP Development EnQineerinQ (Name and Position, e.g. President, Plant Manager, Chief Engineer)

of Ashcroft Inc. (Name of Manufacturer)

Located at 250 East Main Street, Stratford, CT, USA (Plant Address)

203.378.8281 (Te/ep/lone No.)

203.385.0408 (Fax No.)

[J do solemnly declare that 'the fittings listed hereunder, which are subject to the Technìcal Standards and Safety Act, .Boilers and Pressure Vessels Regulation, comply with all of the requirements of

CSA B51, ASME BPV Code Section VIII Dtvision 1, ASME B31.3, ASMEB31.1, CSA C22.261010-1 .(Title of recognized North American Standard)

which specifies the dimensions, materials of construction, pressureltemperature ratings, identification marking the fittings and .service;

o or are not covered by the pr.ovisions of a recognized North American standard and are therefore manufactured to comply with as

supported by the attached data which identifies the dimensions, material of construction,

pressure/temperature ratings and the basis for such ratings, the marking of the fitting for identification and service.

J further declare that the manufacturè of these fittings is controlledbya quality system meeting the requirements of ISO 9001 :2000

which has been verified by the following authority, Lloyd's Register Quality Assurance (LRQA Inc. Houston). The items covered by this declaration, for which I seek registration, are category F type fittings. In support of this application, the following information and/or test data are attached as follows:

PRP01..DS.001, Rev 1; MAWP-02 (drawings, calculationS,testreports, etc.)

Declared before me at 0-iYr.ft-fbm. e-r t.(Min the CO IJ./J{ 7f' of ~a.j'rNjd,

the_---d5 _

day of cJ Une AD 2009

{()!/m b t'OL 111

'I (Printed flame)

~_ .

CQ ,'f;Z ,

.10iJ (À Ê(](fJ/YJ~(ì .

.

.

( Signature) '-J

lfJe:re.seenxõ

éKf' '8/31/09 (Sìgnature of Declarer)

Commissioner for Oaths:

FOR OFRCE USE ONLY

To the best of my knowledge and belief,the application meets the requirements of the

Technical Standards and Safety Act, Boilers and Pressure Vessels Re~ulaUon,and CSA Standard 851 and is accepted for registration in Category F I

. ~8A INTERNATIONAL

REGISTERED

CRN: CSA-oF,29C}4}SbADDI~

Registered by:R. ßARNE:S

Dated: ÐECE ì''lPJER 7, 2004

NOTE: This registration expires on HA'I I 2-019 PV 09553 (06/04) NOTE: SEE::' ATT1\ CHMEt--Sí Fc:;(.2... CS<::oÆ

C.R.N.:

Sipcd:

Date; Df.cEMf?JeR. 7/ 2Cb'1 178 Reàte Blvd., Toronto. ON MgW 111t3

oç:. r<.Ë6' ST12ATl ò

f....,;fõ .

I

/ .

~ASHCROFJ'j'NC.

250 East Main Street

Stratford, CT 06614

USA

Tel: 203-378-8281

Fax: 203.385.0408

Email: [email protected]

www.ashcroftinc.com

'~ASHCROFT

~HEJSE

wntY'

.ebrcl"

ffWEKSLER'

~

Ms. Cathy Turylo Manager, Engineering Services

Boilers and Pressure Vessels Safety

Technical Standards & Safety Authority 14th Floor, Centre Tower

Toronto, Ontario

Canada M8X 2X4

... "

CAiADIAllIIA:'.IDJune 24, :W09 AlIDCIAfllI

- -

PMe:- loF , ATTACHMENTTO '

RE:

CRN~I SIGNED

Summary of Addendum to OF1299:~lm~:rrJ3ronto.ON C.nada M9WIR3

Dear Ms. Turylo

The attached request for addendum addresses the omission of the diaphragm seal

types 105 & 205 from the original approved CRNOF12994.

Seal configurations were identified in chapter 2 of the design registration package

DCROl-DS-OOI, Rev. 0 as the weakest components, and witness burst test results

were a.ccordinglyconducted and included in the design registration package under approved eRN OF12994. Seal configurati.ons associated with diaphragm seal

types 105 & 205 do not differ from those previously burst tested under ASME BPV code Section VIII, Div. 1 UG-IOland approved in eRN OF12994. Furthermare, catalogue information includedinCRN OF12994 does not need to be updated.

This addendum pertains exclusively to the omission of the circumferential and longitudinal stress calculations for the process connections of diaphragm seal types 105 and 205 respectively, the inclusion of the relevant drawings I the design

registration, and the inclusion of these diaphragm seal types in the summary table,

that is referenced by the statutory declaration.

Accordingly, Appendix I of this letter summarizes the inclusion of tabular

circumferential and longitudinal stress calculation for diaphragm seal types 105 and

205. Appendix II includes the drawings. A revision of the originalMA WP tabular

summary, with changes highlìghted, is found in Appendix III.

As always, thank you for YOllr kind assistance. THIS is PAR:r=6F1 eRN f) f (1-crq~,r A-.Þ.!J{ ì

l"echnicalStandards & Safety A!ithorfty 1 Boilers & Pressure Vessels i

Safety -Rrogram \

Ro bert D Thomas VP Development Engineering

Ashcroft Inc.

Page I of 14

@ CERTIFICATE OF APPROVAL

This is to certify that the Quality Management System of:

Ashcroft, Inc. Stratford, Connecticut, USA

has been approved by Lloyd's Register Quality Assurance to the following Quality Management System Standards:

ISO 9001:2000

The Quality Management System is applicable to:

Design and Manufacture of Pressure and Temperature Calibration Equipment. Distribution of Pressure and Temperature Control Equipment Sourced Globally.

Approval

Certificate No: UQA 0100118 Original Approval: January 11, 1994

Current Certificate: February 1,2009

Certificate Expiry: January 31, 2012

This document is subjed to the provision on the reverse 1401 Enclave Parkway, Suite 200, Houston, Texas 77077, USA

lhis;PPfovil iSQrri~d Gut in Õlcçord~nce with the lRQAa-s~.Siment ;od certification procedures ~ndmonilCied by lRQA. M-.ut&~.1'

250 East Main Street, Stratford, CT, USA 06614. Tel 203.378.8281. Fax 203.385.0408.

Seal A Seal B Seal C Seal A Seal B Seal C

Metallic 1250 750 730

PVC or Kynar 200 74, 125, 150 200, 125, 80 (2)

1/2, 3/4, 1,

1.5, 2, 3Metallic 150# 750 150#

Teflon 290 150 270

PVC or Kynar 75 100 75

Metallic 1250 750 730

Teflon 1250 400 875

Viton 500 350 365

Kalrez 500 212 425

Metallic 200 74, 125, 150 200, 125, 80 (2)

Nonmetallic 200 74, 125, 150 200, 125, 80 (2)

Metallic 150#, 300#, 600# 750 150#, 300#, 600#

Teflon 400

Viton 350

Kalrez 212

Metallic 290 270

Nonmetallic 290 270

Metallic 200 74, 125, 150 200, 125, 80 (2)

Nonmetallic 75 100 75

Teflon 1250 400 875

Viton 500 350 365

Kalrez 500 212 425

Nonmetallic PVC or Kynar 200 74, 125, 150 200, 125, 80 (2)

Teflon 400

Viton 350

Kalrez 212

Nonmetallic Teflon 290 150 270

Nonmetallic PVC or Kynar 75 100 75

500, 501 500 290

400, 401 4400 2580

402, 4031/2, 3/4, 1,

1.5, 2, 3150#, 300#, 600# 150#, 300#, 600#

Notes:

(1) Types 104, 204, and 304 not available in 1.5". Types 107 and 207 also available in 2". (consult factory). Only Type 105, 205 available in 3" and 4"

(2) Maximum Allowable Working Pressure (MAWP) at respective Maximum Design Temperature. (consult factory)

(3) Seal A - Threaded capsule diaphragm; Seal B - Welded and clamped or welded only diaphragm; Seal C - Bonded/Welded and Clamped or Clamped only diaphragm (consult factory)

(4) Nickel constructions excluded. Metallic materials UNS S31603 equivalent or stronger are qualified under this CRN registration. (consult factory)

150#

150# 150#

150

Codes of

Construction

ASME B31.1

ASME B31.3

ASME B16.5

ASME Boiler &

Pressure

Vessel Code

CSA C22.2

61010-1

ANNEX G

1/2, 3/4, 1,

1.5, 2, 3

Metallic 750

Metallic

PVC or Kynar

Teflon

CSA C22.2

61010-1

ANNEX G

150#

200, 201,

204, 207,

205

PVC or Kynar

100, 101,

104, 107

105

Metallic

Metallic

1/4, 1/2,

3/4, 1, 1.5

3, 4

1/4, 1/2,

3/4, 1, 1.5

3, 4

1, 1.5, 2

1/4, 1/2,

3/4, 1

1/2, 3/4, 1,

1.5, 2, 3

Metallic

1/4, 1/2,

3/4, 1, 1.5

1, 1.5, 2

1.5, 2

Ashcroft

Diaphragm

Seal Type

Maximum Design

Temperature T (oF)

MAWP at ambient

(psi or ASME B16.5 class #) (3)Size (in) (1)

MAWP-02

Metallic300, 301,

304

302, 303

Metallic

202, 203

MAWP at Maximum Design Temperature

(psi or ASME B16.5 class #) (3)

102, 103

Diaphragm

Material (4)

Bottom Housing

Material (4)

Inspection and Technical Services Manitoba 500- 401 York Avenue Winnipeg Manitoba R3C OP8 T (204} 945-3373 F(204)948-2309 www.firecomm.gov.mb.ca/codes_steam_pressure.html

March 2, 20 15

ASHCROFT INC. 250 MAIN ST. STRATFORD, CT 06614

Attn: JEREMY PAYNE

REGISTRATION OF VALVES AND FITTINGS

Manufacturer: ASHCROFT INC.

The design(s) for the following Valves/Fittings has been received by us and has been examined and accepted for registration in the Province of Manitoba as follows.

DRAWING I CATALOGUE CRN FILE

Models: DFE, DF, Type 702,703,740,741,510/511, OF12994.54 34875

310,315,311,/312

An invoice covering survey and registration fees is enclosed.

NOTE: CRN registered under reciprocal agreement & is conditional based on compliance with the notes set by the original issuing Jurisdiction: TSSA. This registration expires May 1, 2019.

This registration is valid until the indicated expiry date only if the Manufacturer maintains a valid quality management system approved by an acceptable third-party agency until that date. Should the approval of the quality management system lapse before the expiry date indicated above, this registration shall become void.

The registration of this design does not relieve the manufacturer, the owner or his agent of the responsibility for the design or construction of a fitting in accordance with the applicable Acts, Codes and Standards. Inspection and Technical Services assumes no responsibility by registering designs, examining plans and/or inspecting equipment or facility.

r~~ Ryan Orlesky, C.E.T. Design Surveyor Office of the Fire Commissioner Inspection and Technical Serv1ces Manitoba 500 - 401 York Avenue Winnipeg, Manitoba, R3C OP8 Phone: 204-945-3373 Email: [email protected]

MANITOBA DEI•ARTMENT OF LABOUR AND IMMIGRATION 500 - 401 YorkAvenue Winnipeg, Manitoba R3C OPll STATUTORY DECLARATION

r--- -------------------------=RE=G=-=I=S..::.T~RATION OF FITTINGS

(u) Design Qualification

I. Phillip Reed (See Note 2)

Quality Assurance Manage r (Position e.g.: president , plant manager, chief eng.)

of Ashcroft, Inc.

(Name of company)

located at 250 East Main Street, Stratford, Connecticut 06614, USA

(Plant Addres~)

do solemnly declare that the fittings listed hereunder, which are subject to the Boilers & Pressure Vessels Act.

comply with all the requirements of the ANSIIASME codes as to their dimensions. or

,/ are not covered hy the provisions of the ANSI/ ASME code~, and are therefore constructed to comply with ASME 831.3; ASME 840.2 code or Mandard, and are des igned to the best current engineering practice, as shown by the supporting test data.

(b) Quality Control of Manufacture

I further declare the manufacture of these fi ttings is controlled by a quality co trol progmm which complies with the requirements of ISO 9001 :2008 , and ha' been verified by the following authority or authorized agency _L=Rc..:.Q-=-A=-----------------

The fi tt ings covered by this declaration. for which I seek registration, are _F ____________________ __ _

Jn support of the application, the following information, calculations and/or test data are auached:

Diaphragm Seals catalogues: DFE; OF, Type 702, 703 & 740, 741 ; TyPe 510/511 , TyPe 310, 315, TyPe 311/312

I

-~ I

The app ·cation is uccepted for registration in Category (For Official Use Only)

' £ · · in accordance with the Boilers and Pressure Vessels Act and CSA Standard 851.

This registrdtion must be revalidated after ten ( I 0) years from the date of acceptance.

~: MAY ' I -z_otCf

Registered Number C~ 0=F l ~C) 9 Lf · :; 1

~ For the Chief I n~pector

Date: ____:.l'IA-L.L..--"'1(~....:::)~/f-' ....:...'ZAJ_ I _J__. ________ _

Notes: (1) 111il'furm shall be completed and signed by I he president or highest official in the munufaclll ring pltml where lhe filling is produced. (2) Two completed copies of Stall/tory Declaration foml lOge/her with two copies of Catalog.t, drawings or Bulletin.\· illustratin abm•e fillings shall be submitted. (3) All jiltings are required 10 be registered in the name of I he Manufactllrer.

Product

310

315

311

312 510 511 702

703

740 741

OF

DFE

NOTES [I] [2]

[3]

• · & Of!lce of the Are

~ASHCROFT 1 11 Services Convnfssfonor

o liJ<1

250 Main Street, Stratford, CT 06614-5145, USA

Scope of Registration Summary - Diaphragm Seals

f-IlS IS PART OF CRN

¢FI;2C}Cf~-S4 L - ------'

Design Weakest

Design Housing & Process Connection Size Temp. Code of

Type (in) [1)

Pressure eF>

Diaphragm Construction (psi) [2)

[2) Material

(4, 5) 1/8, 1/4, 3/8, 1/2, 3/4, 1

male 2500 1/4, 3/8, 1/2 female

1/4, 3/8, 112 female All welded 1/4, 1/2, 3/4, 1

male or female 1000 316L l/4, 1/2 female

1/2 male 1500 or UNS

5000 S31603 ASME

Flanged 112, 3/4, 1, 1 112, 2, 3 816.5150# -70 to ASME 831.3

to 600# 750

Threaded 114, 112, 3/4, 1 750

Welded ASME Diaphragm

flanged 2, 3, 4 816.5150# & Flange:

to 2500# 316L UNS Welded S31603 flanged ASME

with 1, 1 1/2 816.5150# Hub: internal to 300# 316Ti UNS

diaphra2m S31635

Except for flanged models, connections are NPT type per ASME B 1.20.1. Design pressure given at 100°F, for de-ratings see B 16.5. Minimum design temperature limited by fill fluid. Models 315, 312, 511, 703, 741 supplied with flushing connection.

The undersigned hereby declares that that above is accurate and representative,

Name: Jeremy M. Payne

Signature: ;:::::JitU'"Z

Sheet 1 of1

Title: Materials and Testing Eng. Manager

Date: December 4th, 2014

MANITOBA DEPARTMENT OF LABOUR AND IMMIGRATION 500 - 401 York A venue Winnipeg, Manitoba RJC OP8 STATUTORY DECLARATION

REGISTRATION OF FITTINGS .----------------------------------------------------- ----~~~~~~~~~~~~~

(a) Design Qualification

1. Phillip Reed (See Note 2)

Quality Assura nce Manager (Position e.g. : president, plant manager, chief eng.)

of Ashcroft Instruments GmbH

(Name of company)

located at Max-Pianck-Str. 1, D-52449 Baesweiler, Germany

(Plant Address)

do solemnly declare that the tilting.~ listed hereunder. which are subject to the Boilers & Pr ssure Ve. sels Act,

comply with all the requirements of the ANSU ASME codes as to their dimensions. or

./ are not covered by the provisions of the ANSI/ ASME codes. and are therefore constructed to comply with ASME 831 .3; ASME 840.2 code or standard, and are designed to the best current engineering practice, ru shown by the supporting test data.

(b) Quality Control of Manufacture

I further declare the manufacture of these fittings is controlled by a quality control progmm which complies with the requirements of ISO 9001 :2008 , and has been veri fied by the following authority or authorized agency _T-'-='U-"V....:R...:;h"'e""in"'l""a::.;n=.d ______ . ____ _

The fittings covered by th is declar.ttion, for which I seek registration. are _F _____ _________________ _

In support of the application, the following information, calculations and/or test data are attached:

Diaphragm Seals catalogues : DFE; DF; Type 702, 703 & 740, 741 ; Type 510/511 ; Type 310, 315; Type 311/312

The application is accepted for registration in Category and CSA Standard 851 .

(For Official Use Only) •· £ " in accordance with the Boilers and Pressure Ves.~el s Act

This registration must be revalidated after ten ( 1 0) years from the date of acceptance.

~XP: MAY I 2o\q

Registered Number CR 0 F I a q q Lj . ~?±

~) For the Chief Inspector

Date: MA{< 3 ;2o/ o-I

Notes: (1) This form shall be completed a11d signed by the preside11t or highest official i11 the ma11ufacturi11g pla11t where tire firt ing is {Jroduced. (2) Two completed copies of Statutory Declaration fonn together with two copies of Catalogs, drawings or Bulletins illustrating abol'e fitt ings shall be submitted. (3) All fittings are required to be registered in the name of the Manufacturer.

Product

310

315

311

312 510 511 702

703

740 741

DF

DFE

NOTES [I] [2]

[3]

Inspection & Oftlce of lhe Are

~:~!;':.' Services Commissioner

~ASHCROFT® MonUoba~

THIS IS PART OF CRN

250 Main Street, Stratford, CT 06614-5145, USA 0-Fl c2004. St Scope of Registration Summary - Diaphragm Seals

Design Weakest

Design Housing & Process Connection Size Temp. Code of

Type (in) [1]

Pressure (oF) Diaphragm Construction

(psi) [2] [2]

Material [4, 5]

118, 114, 3/8, 112, 3/4, 1 male

2500 114, 3/8, 112 female 1/4,3/8, 112 female

All welded 114, 112, 3/4, 1 male or female 1000 316L 114, 112 female

112 male 1500 or UNS

5000 S31603 ASME

Flanged 112, 3/4, 1, 1 112, 2, 3 B16.5150# -70 to ASME B31.3

to 600# 750

Threaded 114, 112, 3/4, 1 750

Welded ASME Diaphragm

flanged 2, 3, 4 B16.5 150# & Flange:

to 2500# 316L UNS Welded S31603 flanged ASME

with 1, 1112 Bl6.5150# Hub: internal to 300# 316Ti UNS

diaphra2m S31635

Except for flanged models, connections are NPT type per ASME 8 1.20.1 . Design pressure given at I 00°F, for de-ratings see 8 16.5. Minimum design temperature limited by fill fluid. Models 315, 312, 511 , 703, 741 supplied with flushing connection.

The undersigned hereby declares that that above is accurate and representative,

Name: Jeremy M. Payne

Signature: ciiS'Ui

Sheet 1 of 1

Title: Materials and Testing Eng. Manager

Date: December 4th, 2014