NX_Errors - 8.5

230
Fixed Problem Reports NX 8.5 13975 72 Siemens PLM believes that the problem you reported where Routing Steepwork could not use Transform Path to rotate a stock cross- section will be resolved by code changes made to the upcoming release of our software NX 8.5. Transform Path cannot rotate a stock cross- section by design, so instead, the Edit Stock function should be used to change the orientation. 14024 34 Siemens PLM believes that the problem you reported where 'an error received for 2 overlapping Chamfers during unsuppress' will be resolved by code changes made to the upcoming release of our software NX 8.5. 14164 36 PS25.00.149: Chamfer 38 fails during update. 14940 11 Siemens PLM believes that the problem you reported where a variable_contour, surface area drive method would skip a portion of the surface and gouge will be resolved by code changes made to the upcoming release of our software NX 8.5. 15059 83 Siemens PLM believes that the problem you reported where a Cavity Mill operation gouges the part will be resolved by code changes made to the upcoming release of our software in NX 8.5. 15083 99 Siemens PLM believes that the problem you reported where Maintain work part does not maintain work occurrence will be resolved by code changes made to the upcoming release of our software NX 8.5.0.17. 15115 83 Siemens PLM believes that the problem you reported where the 'Extend Tangent' option for Corner Control was suppressing some of the linear moves for an arc will be resolved by code changes made to the upcoming release of our software NX 8.5. 15161 71 Siemens PLM believes that the problem you reported where Measured distance between a point and a surface is incorrect will be resolved by code changes made to the upcoming release of our software NX 8.5. 15255 74 Siemens PLM believes that the problem you reported where the Spun outline from Solid fails will be resolved by code changes made to the upcoming release of our software NX 8.5. 15315 96 Siemens PLM believes that the problem you reported where Chamfer(38) fails to update will be resolved by code changes made to the upcoming

Transcript of NX_Errors - 8.5

Page 1: NX_Errors - 8.5

Fixed Problem ReportsNX 8.5

1397572

Siemens PLM believes that the problem you reported where Routing Steepwork could not use Transform Path to rotate a stock cross-section will be resolved by code changes made to the upcoming release of our software NX 8.5. Transform Path cannot rotate a stock cross-section by design, so instead, the Edit Stock function should be used to change the orientation.

1402434

Siemens PLM believes that the problem you reported where 'an error received for 2 overlapping Chamfers during unsuppress' will be resolved by code changes made to the upcoming release of our software NX 8.5.

1416436

PS25.00.149: Chamfer 38 fails during update.

1494011

Siemens PLM believes that the problem you reported where a variable_contour, surface area drive method would skip a portion of the surface and gouge will be resolved by code changes made to the upcoming release of our software NX 8.5.

1505983

Siemens PLM believes that the problem you reported where a Cavity Mill operation gouges the part will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1508399

Siemens PLM believes that the problem you reported where Maintain work part does not maintain work occurrence will be resolved by code changes made to the upcoming release of our software NX 8.5.0.17.

1511583

Siemens PLM believes that the problem you reported where the 'Extend Tangent' option for Corner Control was suppressing some of the linear moves for an arc will be resolved by code changes made to the upcoming release of our software NX 8.5.

1516171

Siemens PLM believes that the problem you reported where Measured distance between a point and a surface is incorrect will be resolved by code changes made to the upcoming release of our software NX 8.5.

1525574

Siemens PLM believes that the problem you reported where the Spun outline from Solid fails will be resolved by code changes made to the upcoming release of our software NX 8.5.

1531596

Siemens PLM believes that the problem you reported where Chamfer(38) fails to update will be resolved by code changes made to the upcoming release of our software NX 8.5.

1546560

Siemens PLM believes that the problem you reported where Zlevel Profile does not cut correctly will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1547144

Siemens PLM believes that the problem you reported where in NX4 changing the offset for a datum plane used to trim the drive surface in a Fixed Contour operation produces a different toolpath than in NX 3 with the same change will be resolved by code changes made to the upcoming release of our software NX 8.5.

1548053

NX drop out if Item name too long / Needs a better message.

Page 2: NX_Errors - 8.5

1556070

Siemens PLM believes that the problem you reported where the spun outline generation for the solid body in the PR part failed will be resolved by code changes made to the upcoming release of our software NX 8.5.

1561712

Siemens PLM believes that the problem you reported where the spun outline generation for the solid body in the PR part failed will be resolved by code changes made to the upcoming release of our software NX 8.5.

1563542

Siemens PLM believes that the problem you reported where a "Dwell" event does not appear in the postprocessed output will be resolved by code changes made to the upcoming release of our software NX 8.5.

1567912

Siemens PLM believes that the problem you reported where creating the 2D shape from a solid body fails will be resolved by code changes made to the upcoming release of our software NX 8.5.

1573584

Siemens PLM believes that the problem you reported where the spun outline generation for the solid body in the PR part failed will be resolved by code changes made to the upcoming release of our software NX 8.5.

1576725

Siemens PLM believes that the problem you reported where the spun outline generation failed for the solid body in the PR part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1578044

Siemens PLM believes that the problem you reported where the user was getting the message "Cannot derive outline from solid" when creating a Turning Workpiece will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1579564

Siemens PLM believes that the problem you reported where creating the spun outline from a solid body fails will be resolved by code changes made to the upcoming release of our software NX 8.5.

1584685

Siemens PLM believes that the problem you reported where the spun outline generation failed for the solid body in the PR part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1590617

Siemens PLM believes that the problem you reported where using the Reference Tool option causes some levels to be skipped will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1593033

Remove edge traces prevents machining of all cut area faces.

1604055

Siemens PLM believes that the problem you reported where in a Cavity Mill operation with "Motion Output" set to "Linear Only" there is a "CIRCLE/" move output will be resolved by code changes made to the upcoming release of our software NX 8.5.

1611334

Siemens PLM believes that the problem you reported where UDEs are not working after the NX 4 update will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1615878

Siemens PLM believes that the problem you reported where attempting to create a spun outline from a solid body fails will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 3: NX_Errors - 8.5

1615922

Siemens PLM believes that the problem you reported where attempting to create a spun outline from a solid body fails will be resolved by code changes made to the upcoming release of our software NX 8.5.

1615929

Siemens PLM believes that the problem you reported where the spun outline generation failed for the solid body in the PR part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1617862

Siemens PLM believes that the problem you reported where the spun outline generation failed for the solid body in the PR part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1619557

Siemens PLM believes that the problem you reported where the spun outline generation failed for the solid body in the PR part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1629304

Siemens PLM believes that the problem you reported where the user was unable to Create the Lathe Cross Section will be resolved by code changes made to the upcoming release of our software NX 8.5.

1639130

Siemens PLM believes that the problem you reported where NX can not derive an outline from the solid body solid will be resolved by code changes made to the upcoming release of our software NX 8.5.

1640315

Siemens PLM believes that the problem you reported where the Open C API function UF_ASSEM_apply_mc_data created old mating conditions, even though the assembly preference was set to Positioning Constraints, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1644201

Siemens PLM believes that the problem you reported where part updates in NX 5.0.2, fails in NX 5.0.3 on Trim Body feature will be resolved by code changes made to the upcoming release of our software NX 8.5.

1644739

Siemens PLM believes that the problem you reported where the CUTCOM/OFF does not come out after the Lead Out as specified will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1650665

Siemens PLM believes that the problem you reported where Spun outline does not create the correct geometry will be resolved by code changes made to the upcoming release of our software NX 8.5.

1662379

Siemens PLM believes that the problem you reported where spun outline generation for given solid body in turning failed with error message will be resolved by code changes made to the upcoming release of our software NX 8.5.

1667258

Save All and Exit on read only part running NX from TC gives no save failure war.

1669047

Siemens PLM believes that the problem you reported where CMM failed to create the NX part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1675379

Siemens PLM believes that the problem you reported where in Cavity Mill, the use of Corner Control results in tool motion in the lower levels that was not there in the upper levels will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 4: NX_Errors - 8.5

1675692

Siemens PLM believes that the problem you reported where in Wire EDM the defined FROM points change after operations are generated will be resolved by code changes made to the upcoming release of our software NX 8.5.

1677399

Siemens PLM believes that the problem you reported where NX5 Macro playback error while exporting parasolid by 2 point selection will be resolved by code changes made to the upcoming release of our software NX 8.5.

1677557

Siemens PLM believes that the problem you reported where using Delete Face would not remove all the holes on a face will be resolved by code changes made to the upcoming release of our software NX 8.5.

1677864

The problem where "Interval for Save Changes Reminder option works in an unexpected way" is working as designed.

1681410

Siemens PLM believes that the problem you reported where you were unable to create a Spun Outline from Solid Geometry will be resolved by code changes made to the upcoming release of our software NX 8.5.

1682934

Siemens PLM believes that the problem you reported where the spun outline generation failed for the solid body in the PR part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1683403

Siemens PLM believes that the problem you reported where Tool Path--> Verify -> Compare shows gray color for freeform areas only will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1684678

Siemens PLM believes that the problem you reported where the 3D IPW is displayed at the wrong location using auto block will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1685413

Contour Flange Start and End Miters not creating consistent.

1686260

Siemens PLM believes that the problem you reported where the tool path generated results in tool collisions with the In-Process Workpiece will be resolved by code changes made to the upcoming release of our software NX 8.5.

1686399

Siemens PLM believes that the problem you reported where collision occur with lowest Z option in transfer move will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1686425

Siemens PLM believes that the problem you reported where you were unable to generate a spun outline from the solid body will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1687191

CAD:WAVE -> Interpart Link Browser UI problem when changing bundles.

1687844

Siemens PLM believes that the problem you reported where a drilling operation adopted into Knowledge Fusion does not appear on the KF Navigator will be resolved by code changes made to the upcoming release of our software NX 8.5.

1690843

Siemens PLM believes that the problem you reported where a Flat Pattern shows a different length result than a Flat Solid, will be resolved by code changes made to the upcoming release

Page 5: NX_Errors - 8.5

of our software NX 8.5. The fix has been provided with a version check. This means that a new Contour Flange feature will have to be created to see the fixed behavior.

1690920

Siemens PLM believes that the problem you reported where in a Rough Turn operation the tool machines an area already cut will be resolved by code changes made to the upcoming release of our software NX 8.5.

1693311

Siemens PLM believes that the problem you reported where one particular pair of faces would only mesh mate as noncoincident glue, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

1695497

Siemens PLM believes that the problem you reported where there were element shape issues in NX Thermal/Flow will be resolved by code changes made to the upcoming release of our software NX 8.5. With new model check:

1. Duplicate Nodes could check out "1454 duplicate nodes found, 727 nodes to be merged".

2. Element Quality Check ============================================================================== Overview Number Failed Number Checked Elements 17423 2546645 Check Number Failed Worst Value Tet Collapse 21 1564.82193 Jacobian Ratio 1 109.68750 Jacobian Zero 0 0.87083 Aspect Ratio 18 47.46023 Skew Angle 0 79.04980 Maximum Interior 1332 175.95042 Angle Minimum Interior 15985 5.85600 Angle Taper 808 0.18095 Warp 1491 36.34534 Since most elements fail on the Minimum Interior Angle check, you could change the threshold value so they can pass this check as acceptable elements.

1695883

Siemens PLM believes that the problem you reported where depending on whether you select the boundary plane as "Automatic" or "Manual" you get two different boundaries created will be resolved by code changes made to the upcoming release of our software NX 8.5.

1696319

Siemens PLM believes that the problem you reported where UF_CAMBND_append_bnd_from_curve doesn't work with WEDM 4-axis and rotated MCS will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1704902

Siemens PLM believes that the problem you reported where UF_CAMBND_ask_item_entity returns NULL_TAG with WEDM 4axis will be resolved by code changes made to the upcoming release of our software NX 8.5.

1706251

Siemens PLM believes that the problem you reported where the Wave Geometry Linker name/attribute mapping is inconsistent will be resolved by code changes made to the upcoming release of our software NX 8.5.

1707269

CAD: "Allow Menubar Customization" set to off restores the default role always.

1707564

Siemens PLM believes that the problem you reported where attempting to create a spun outline from a solid body fails will be resolved by code changes made to the upcoming release of our software NX 8.5.

1709907

Siemens PLM believes that the problem you reported where the documentation for the NXOpen NXMessageBox method was inadequate will be resolved by code changes made to the upcoming release of our software NX 8.5.

17164 Siemens PLM believes that the problem you reported where the Tool Gouges the Part in

Page 6: NX_Errors - 8.5

51 Facing Milling will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1717372

The problem where an Advanced Teamcenter Search does not recognize integer or float attributes is resolved in NX 8.5.

1717705

Siemens PLM believes that the problem you reported where in an Area Milling operation not all Cut Area specifications are machined will be resolved by code changes made to the upcoming release of our software NX 8.5.

1721351

Siemens PLM believes that the problem you reported where an error message 'Update/Delete has gone thru too many iterations' was received when opening a file will be resolved by code changes made to the upcoming release of our software NX 8.5.

1721354

Siemens PLM believes that the problem you reported where the spun outline generation failed for the solid body in the PR part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1721358

Siemens PLM believes that the problem you reported where the spun outline generation failed for the solid body in the PR part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1721362

Siemens PLM believes that the problem you reported where the spun outline generation failed for the solid body in the PR part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1721374

Siemens PLM believes that the problem you reported where the spun outline generation failed for the solid body in the PR part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1723541

Siemens PLM believes that the problem you reported where the spun outline generation failed for the solid body in the PR part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1725904

Siemens PLM believes that the problem you reported where creating a spun outline from a solid body fails to produce a complete spun outline will be resolved by code changes made to the upcoming release of our software NX 8.5.

1728027

Siemens PLM believes that the problem you reported where the Spun Outline routine produces gaps will be resolved by code changes made to the upcoming release of our software NX 8.5.

1729241

Siemens PLM believes that the problem you reported where a child rule of the Knowledge Fusion nx_block class did not update correctly when both origin and orientation were changed, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1732083

Siemens PLM believes that the problem you reported where the resulting IPW/Workpiece is not correct for the Counter Spindle will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1732468

Siemens PLM believes that the problem you reported where the documentation for "Machine Data Library Parameter Matching and Interpolation" only contains a single example will be resolved by code changes made to the upcoming release of our software NX 8.5.

17334 Siemens PLM believes that the problem you reported where a turning operation is leaving a

Page 7: NX_Errors - 8.5

48 little "cusp" or scallop on the 2D IPW will be resolved by code changes made to the upcoming release of our software NX 8.0 and NX 8.5.

1734798

Siemens PLM believes that the problem you reported where key press navigation on some ComboBoxes and Option Menus would cause the dropdown to close will be resolved by code changes made to the upcoming release of our software in releaseNX  8.5.

1735257

Siemens PLM believes that the problem you reported where a spun outline generation for a given solid body failed with an error message will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1735794

Siemens PLM believes that the problem you reported where using 'MB3 -> Set Rotate Point -> select point position on body surface' fails in NX 6 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1736214

Siemens PLM believes that the problem you reported where attempting to create a spun outline from a solid body fails will be resolved by code changes made to the upcoming release of our software NX 8.5.

1738397

Siemens PLM believes that the problem you reported where spun outline generation for a given solid body failed with an error message will be resolved by code changes made to the upcoming release of our software NX 8.5.

1740043

Siemens PLM believes that the problem you reported where an Imported CGM file did not display the entire original CGM data, as compared to CGM viewers, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1740671

NX Machining button is disabled (NX 6.0.3.6 and SE 100.00.09.04).

1741721

Siemens PLM believes that the problem you reported where a Perl script in the Windows folder used unix shell commands will be resolved by code changes made to the upcoming release of our software NX 8.5.

1742261

Siemens PLM believes that the problem you reported where Cavity Mill creates erratic Climb and Conventional Cut Paths will be resolved by code changes made to the upcoming release of our software NX 8.5.

1743356

Siemens PLM believes that the problem you reported where a sketch in the provided part contained over constrained geometry when editing a dimension from 200000 to 400000, will be resolved by code changes made to the upcoming release of our software NX 8.5. We have added the ability to set a solving tolerance for a sketch. In the PR scenario, the sketch solving tolerance should be set. Users can pick the sketch in the Part Navigator and select "MB3 -> Style" and toggle on Use Tolerance. The default tolerance is the modelling tolerance and that should work just fine for the PR scenario.

1744783

SYS: PR 1677399 Macro -> Error when selecting with rectangle rubber band.

1746751

Siemens PLM believes that the problem you reported where spun outline generation for given solid body failed will be resolved by code changes made to the upcoming release of our software NX 8.5.

1747285

Siemens PLM believes that the problem you reported where in a Cavity Mill operation the tool is plunging into blank material at various levels will be resolved by code changes made to the

Page 8: NX_Errors - 8.5

upcoming release of our software NX 8.5.

1748840

Siemens PLM believes that the problem you reported where the wrong backburn is generated if the backburn distance is set to 0 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1749384

Siemens PLM believes that the problem you reported where one is unable to create UGPART with specification for MENCMachining in NX if display-filtered in TC will be resolved by code changes made to the upcoming release of our software NX 8.5.

1751237

Siemens PLM believes that the problem you reported where the Tool Path generates erratic motion during the Stepover passes will be resolved by code changes made to the upcoming release of our software NX 8.5.

1751316

Siemens PLM believes that the problem you reported where you were getting the wrong Wire EDM 4 axis toolpath for circles will be resolved by code changes made to the upcoming release of our software NX 8.5.

1751555

Siemens PLM believes that the problem you reported where turning a mirrored component gives the error "Cannot derive outline from solid" will be resolved by code changes made to the upcoming release of our software NX 8.5.

1753209

Siemens PLM believes that the problem you reported where NX would fail to create several MMCs will be resolved by code changes made to the upcoming release of our software NX 8.5.

1755583

Siemens PLM believes that the problem you reported where the spun outline generation failed for the solid body in the PR part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1757336

Siemens PLM believes that the problem you reported where you could not create a Monolithic assembly .jt file and import it into Teamcenter, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1757342

Algorithm for Cleanup Movement does not realize Stock Values.

1759291

Siemens PLM believes that the problem you reported where Spun Outline creation returns the error "Cannot derive outline from solid" will be resolved by code changes made to the upcoming release of our software NX 8.5.

1761815

Siemens PLM believes that the problem you reported where the spun outline generation failed for the solid body in the PR part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1762836

Siemens PLM believes that the problem you reported where in TCIN there was no option to create a specification for MoldWizard component drawings, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1762905

Importing customer Defaults results in error messages.

1764744

Siemens PLM believes that the problem you reported where there was no localization of the Menu: "Insert -> Design Feature -> Thread", will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 9: NX_Errors - 8.5

1766257

Siemens PLM believes that the problem you reported where Unable to filter by comment in expressions dialog will be resolved by code changes made to the upcoming release of our software NX 8.5.

1767105

Siemens PLM believes that the problem you reported where NX can not create a spun outline from a solid body will be resolved by code changes made to the upcoming release of our software NX 8.5.

1768396

Siemens PLM believes that the problem you reported where Attribute values of groups are not visible from Properties, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1774098

Siemens PLM believes that the problem you reported where the Status Line and Quick Pick dialog did not show the feature number for datum planes or datum axes, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1774558

Siemens PLM believes that the problem you reported where UF_CURVE_create_line, UF_CSYS_create_matrix, UF_CURVE_create_arc and UF_CURVE_create_spline_thru_pts required Modeling and Drafting licenses will be resolved by code changes made to the upcoming release of our software NX 8.5.

1776690

Siemens PLM believes that the problem you reported where 2D Dynamic shows erroneous collisions for a Holemaking group will be resolved by code changes made to the upcoming release of our software NX 8.5.

1776954

Siemens PLM believes that the problem you reported where attempting to edit expressions in a program when there was no displayed part in the session resulted in an internal error will be resolved by code changes made to the upcoming release of our software NX 8.5.

1778186

Siemens PLM believes that the problem you reported where in the Machine Tool View of the Operation Navigator if you have a "Tool Number" order of "5-2-1-4-3" and you order them to "1-2-3-4-5" then delete number "3" the order will automatically go back to "5-2-1-4" will be resolved by code changes made to the upcoming release of our software NX 8.5.

1780404

Siemens PLM believes that the problem you reported where expressions were initially invisible in the Expression Editor after adding UDF with threaded hole, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1780545

Siemens PLM believes that the problem you reported where creating a Fillet Weld, the face selected is moving when it is on a promoted body will be resolved by code changes made to the upcoming release of our software NX 8.5.

1781004

Siemens PLM believes that the problem you reported where the simulation option "Stationary - Tool" causes sync-manager to be unusable will be resolved by code changes made to the upcoming release of our software NX 8.5.

1781671

Siemens PLM believes that the problem you reported where the meaning of "Drill Direction" in a hole table in the Drafting Help is not explained will be resolved by code changes made to the upcoming release of our software NX 8.5.

1781883

Siemens PLM believes that the problem you reported where the user Cannot update part family members after creating new revision, will be resolved by code changes made to the upcoming release of our software NX 8.0.3.

17829 Siemens PLM believes that the problem you reported where the "ug_export" utility was

Page 10: NX_Errors - 8.5

92 reporting an error in the syslog: "UGMGR__is_hookup_spec got a long name", will be resolved by code changes made to the upcoming release of our software NX 8.5.

1783079

Macro to export parasolid from rectangle selection fails to playback.

1783413

Siemens PLM believes that the problem you reported where an invalid Turning section was being generated will be resolved by code changes made to the upcoming release of our software NX 8.5.

1787238

Siemens PLM believes that the problem you reported where save as new item in NX within assembly - the old component is loading, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1789236

Siemens PLM believes that the problem you reported where display smooth edges was not correct, will be resolved by code changes made to the upcoming release of our software NX 8.5. This problem is fixed by an NX 8.5 change to the smooth-edges functionality. For more information about these changes, refer to topic "Smooth Edges Visualization Enhancement" in the "What's New in NX 8.5" documentation.

1790074

Siemens PLM believes that the problem you reported where a Journal created with only a CAM Express license cannot be played back with only a CAM Express license will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1790395

Siemens PLM believes that the problem you reported where a UDE with the 'Type P' setting causes fixed points to appear for screen picks will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1792043

Siemens PLM believes that the problem you reported where you could not specify a component group when using UF_ASSEM_specify_filter in an external program will be resolved by code changes made to the upcoming release of our software NX 8.5. The documentation will clarify the fact that this call is only valid with internal programs.

1792820

Siemens PLM believes that the problem you reported where a Zlevel corner cleanup operation skips some levels is fixed in NX 8.5 by the project of Efficient Rest Material Removal with Reference Tools. The customer can create a flowcut operation by using zlevel and flowcut patterns together with zlevel pattern cutting of nonsteep areas and crosscut pattern cutting steep areas to replace the original zlevel operation.

1794364

"Reference only" component is not recognized opening precise assembly.

1794812

Siemens PLM believes that the problem you reported where detailed stock style returned "invalid string definition" for the provided part will be resolved by code changes made to the upcoming release of our software NX 8.5. As a workaround: Simply re-assign the same stock to the spline. It will return a bend radius rule violation, that can be ignored. After that, change the stock detail to high. It will no longer give the error. The error was likely caused by a bug in a previous version of NX, or some problem from jumping from one version of NX to the next. Re-assigning the stock will use the modern, correct stock code.

1795472

Siemens PLM believes that the problem you reported where the Deceleration for Roughing Feedrate in Turning does not work as expected will be resolved by code changes made to the upcoming release of our software in NX 8.5.

17964 Siemens PLM believes that the problem you reported where Trim and Extend was splitting the

Page 11: NX_Errors - 8.5

86 faces of a Draft feature, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1796866

Extend Start Setting doesn't work,hole feature creates hole in the opposing side.

1797161

Siemens PLM believes that the problem you reported where in a Zlevel Profile operation there are levels of cut that are skipped will be resolved by code changes made to the upcoming release of our software NX 8.5.

1798538

Siemens PLM believes that the problem you reported where it is not possible to replace a component from a CAM assembly will be resolved by code changes made to the upcoming release of our software NX 8.5.

1798592

Siemens PLM believes that the problem you reported where the NXOpen Programmer's Guide did not explain the limitations when linking objects to a UDO using an owning link, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

1800957

The problem where using Quick Search Enter is not working on the numeric keyboard is fixed in release NX 8.5.

1801815

Siemens PLM believes that the problem you reported where the EDU dialog does not wrap the error message displayed will be resolved by code changes made to the upcoming release of our software NX 8.5.

1803617

GetFaces does not work for Instance Geometry feature.

1804493

Siemens PLM believes that the problem you reported where change ExtractedEdges throws internal error if 'Open' is used rather than 'OpenDisplay' will be resolved by code changes made to the upcoming release of our software NX 8.5 IP21.

1804520

Siemens PLM believes that the problem you reported where multiple sheets were selectable but only the first selected sheet was exported via 2DExchange will be resolved by code changes made to the upcoming release of our software NX 8.5.

1805790

Operation ignores the length of the deceleration.

1805894

Siemens PLM believes that the problem you reported where the USER_RCOMP (ufrcp) user exit was no longer called when adding a base view from another part to a drawing, will be resolved by code changes made to the upcoming release of our software NX 8.5. The user exit will be called prior to posting the base view dialog. What happens next is controlled by the return value of the method:

1. Cancels the base view creation command.2. Set the selected part in base view dialog to the valid part name provided by the user

exit function and enable the part selection block so the user can select a different part if desired.

3. Set the selected part in base view dialog to the valid part name provided by the user exit function and disable the part selection block so the user cannot select a different part. n - (any other returned value). Continue normal base view creation.  

1806942

Siemens PLM believes that the problem you reported where Auto Balloons cannot be added to a Detail view will be resolved by code changes made to the upcoming release of our software

Page 12: NX_Errors - 8.5

NX 8.5.

1808697

Siemens PLM believes that the problem you reported where Macro record fails with NX 7.5 Surface Finish Symbols will be resolved by code changes made to the upcoming release of our software NX 8.5.

1810384

Siemens PLM believes that the problem you reported where the Open C function UF_UGMGR_decode_part_file_name() does not return error in NX 7.5.1 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1810498

Siemens PLM believes that the problem you reported where the translators failed in a 4 tier environment if the user account did not have a password will be resolved by code changes made to the upcoming release of our software NX 8.5.

1811991

The Stress wizard hides the window after calculation.

1812588

It takes too long to create a flat pattern for part with 1460 holes.

1813157

Siemens PLM believes that the problem you reported where the user is getting a wavy tool path near the vertical faces in a Contour Area operation will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1815029

Siemens PLM believes that the problem you reported where the Turning IPW is incorrect when Drilling operations are inserted ahead of Turning operations will be resolved by code changes made to the upcoming release of our software NX 8.5. In NX 7.5.5 and NX 8.0.2 the problem is fixed if the environment variable "UGII_CAM_MILL_TURN_CONSIDER_MASTER_CONTOUR" is set to a value of "1". In NX 7.5.5 move "UDE REITSTOCK_SPANNEN_2" from the main spindle (Operation Navigator Geometry View) to the sub spindle under "21_DREHGEOMETRIE" then regenerate "2_SPANNUNG" and no further problems occur. The first turning operation after "GEWINDE_M8X1.25" shows the 2D IPW (Show Filled 2D IPWs) at the wrong position but this is only a display problem and has no impact on the turning/milling processors or Verify. In NX 7.5.5 in "VoithTurbo_damaged_IPW.prt", delete the tool paths from Program Group "2_SPANNUNG" then regenerate the operations and the problem will be resolved. The first turning operation after "XXXX" shows the 2D IPW (Show Filled 2D IPWs) at the wrong position but this is only a display problem and has no impact on the turning/milling processors or Verify.

1815969

Mirror Feature Bend-Taper switches to the wrong side.

1819143

Siemens PLM believes that the problem you reported where NX Ship Shell Expansion curves have bad geometry will be resolved by code changes made to the upcoming release of our software NX 8.5.

1820833

NX-machining Button inactive in assembly env. since NX 7.5 installation.

1821819

Siemens PLM believes that the problem you reported where "save as" new revision is not possible for family member is missing will be resolved by code changes made to the upcoming release of our software NX 8.5.

1822209

Siemens PLM believes that the problem you reported where creating a Flat Pattern failed raising the error: "Feature failed. Verify inputs", will be resolved by code changes made to the

Page 13: NX_Errors - 8.5

upcoming release of our software NX 8.5.

1822613

Siemens PLM believes that the problem you reported where the value for the preview needles is incorrect, when using Surface Continuity Analysis, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1822684

PRO: Step214Creator Commit function does not wait to complete.

1822720

Siemens PLM believes that the problem you reported where a Flat Solid feature failed to create when the Cutout contour runs parallel to the Bend feature will be resolved by code changes made to the upcoming release of our software NX 8.5.

1823221

Siemens PLM believes that the problem you reported where the NXOpen PDMSearch method returns NX datasets only will be resolved by code changes made to the upcoming release of our software NX 8.5.

1823999

Simple hole using Along Vector with depth limit goes through body.

1824422

Siemens PLM believes that the problem you reported where you have problems with the spreadsheet will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

1826595

Siemens PLM believes that the problem you reported where it was not possible to load the referenced master part from the non-master parent if the Teamcenter Integration "Renumbered Parts" Preference was set to "prefer UID", will be resolved by code changes made to the upcoming release of our software NX 8.5. Originally this PR reported that the fix for PR 1814818 did not work in NX 6.0.5 mp4 and that this PR was to have the fix corrected in that version. The problem reported was that having changed the Teamcenter Integration Preference for Renumbered Parts to "Prefer ItemID", opening a Specification loaded the master model with the Reference Set set to Empty. If Renumbered Parts was set to "Prefer UID", NX reported: "Part item not found". First, please note that this is not the same issue as PR 1814818, as implied by the PR text. PR 1814818 was fixed in NX 7.5.3. The problem here is the inability to load the referenced master part from the non-master parent if the Teamcenter Integration "Renumbered Parts" preference was set to "prefer UID", and the associated reference set behavior both in the prefer UID and prefer item ID cases. This problem is fixed in NX 8.5.

1826601

Siemens PLM believes that the problem you reported where it was possible to set options on the Assemblies Load Options dialog by clicking on the far right of the option, away from the toggle or the label, will be resolved by code changes made to the upcoming release of our software NX 8.5. Clicking on the space to the right of the label field will no longer toggle the item. This applies not only to the File Open Dialog, but also to all places where toggles are are shown in dialogs.

1829334

Siemens PLM believes that the problem you reported where an Area Milling drive Non Steep operation only cuts steep areas will be resolved by code changes made to the upcoming release of our software NX 8.5.

1830614

Siemens PLM believes that the problem you reported where you were unable to apply different NX configuration files to the startup, will be resolved by code changes made to the upcoming release of our software NX version 8.5.

18315 Commit() Funktion of IgesCreator is asynchronous.

Page 14: NX_Errors - 8.5

69

1832610

Siemens PLM believes that the problem you reported where the Highlight Hidden Edges option does not apply to CAE meshes will be resolved by code changes made to the upcoming release of our software NX 8.5.

1835107

Siemens PLM believes that the problem you reported where the documentation on creating Sheet Metal Material Standards was insufficient, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1835497

KF function ug_mqc_checkDrawingUpdated returns 0 always.

1835709

Siemens PLM believes that the problem you reported where a Fixed Contouring operation that uses a T-slot cutter hangs NX when generating will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1838038

Siemens PLM believes that the problem you reported where switching from milling to turning does not produce a correct IPW will be resolved by code changes made to the upcoming release of our software NX 8.5. In NX 7.5.5 and NX 8.0.2 the problem is fixed when the environment variable "UGII_CAM_MILL_TURN_CONSIDER_MASTER_CONTOUR" is set to "1".

1838566

Siemens PLM believes that the problem you reported where Control Points 'Events' are not shown graphically but are shown when listed will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1838986

Siemens PLM believes that the problem you reported where it was not possible to delete or unsuppress a curve analysis object, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1839192

Siemens PLM believes that the problem you reported where the orientation of textures applied in NX was not maintained when exporting geometry using VRML 2.0, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1839257

Siemens PLM believes that the problem you reported where one of two boundaries in a 4-axis Wire EDM toolpath is cutting on the wrong side of the part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1840809

Siemens PLM believes that the problem you reported where a misleading "No Write Access" message was reported saving a part from NX to Teamcenter if the Part Name does not conform to naming rules, will be resolved by code changes made to the upcoming release of our software NX 8.5. A precise message will be presented to the user reporting that the naming rule is not being followed.

1840950

Siemens PLM believes that the problem you reported where the values for the length and height of the "GAPxxx" User Defined Symbol dialog were reset to zero having set the size to "Length and Height" and placed the first symbol, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1841120

CAM Express: Error message after sending parts to NX from Solid Edge ST3.

1841195

Tool tip does not display feature number for datum axis or plane.

Page 15: NX_Errors - 8.5

1841816

Wrong dimension after CMM migration.

1842139

Siemens PLM believes that the problem you reported where there was a missing dwell event after a Turning plunge cleanup cut will be resolved by code changes made to the upcoming release of our software NX 7.5.5, NX 8.0.1 and NX 8.5. If a plunge cut is omitted and replaced completely by a cleanup cut a dwell event is now output after that cleanup.

1843266

Siemens PLM believes that the problem you reported where the user was unable to de-select edges of an Extrude feature, while in assembly context, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1843296

Siemens PLM believes that the problem you reported where one of two Cavity Milling operations will not generate unless the top face of the part is selected as Cut Area will be resolved by code changes made to the upcoming release of our software NX 8.5.

1843481

Siemens PLM believes that the problem you reported where a linked body did not update until a feature playback was performed, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1844086

PR1822613 Wrong Surface Continuity Preview.

1844164

The problem where the assembly product structure was not shown correctly in TCVis when JT was exported from Teamcenter is fixed in release NX 8.5.

1845083

Siemens PLM believes that the problem you reported where Expression editor - formula error will be resolved by code changes made to the upcoming release of our software NX 8.5.

1845822

Siemens PLM believes that the problem you reported where Extrude and Symmetric offset with expression is not consistent, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1846267

Siemens PLM believes that the problem you reported where Zlevel Profile, Cavity Mill, and Planar Mill operations that inherit their Clearance Plane from the MCS parent do not have their status changed to "Regenerate" when the Clearance Plane is redefined in the MCS parent will be resolved by code changes made to the upcoming release of our software NX 8.5.

1846681

Siemens PLM believes that the problem you reported where Tool body completely outside target body Alert with Rectangular Groove will be resolved by code changes made to the upcoming release of our software NX 8.5.

1847208

Siemens PLM believes that the problem you reported where the documentation did not explain that the Knowledge Fusion classes nx_pmi_* and other annotation classes are not currently instantiable using a custom dfa file, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

1847249

Siemens PLM believes that the problem you reported where in turning, with Flip and Reorient Tool, the toolpath is bad will be resolved by code changes made to the upcoming release of our software NX 8.5.

1848931

Siemens PLM believes that the problem you reported where a floating feature group is converted to timestamp feature group when it is an input for a downstream feature will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 16: NX_Errors - 8.5

1849365

CMM 7.5: Ordinate Dimensions with tolerances.

1849622

Siemens PLM believes that the problem you reported where a user could not re-associate an angular dimension will be resolved by code changes made to the upcoming release of our software NX 8.5.

1849672

Siemens PLM believes that the problem you reported where "Contact Data ON" with multiple tracking points creates the wrong toolpath will be resolved by code changes made to the upcoming release of our software NX 8.5.

1849949

Siemens PLM believes that the problem you reported where a Deformed component did not Blank the original component, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1851777

Siemens PLM believes that the problem you reported where selecting "File -> Save All" in TCIN did not return the status line message: "All parts successfully saved", will be resolved by code changes made to the upcoming release of our software NX 8.5.

1853652

Siemens PLM believes that the problem you reported where the 'AutoSave Reminder' appeared at irregular intervals will be resolved by code changes made to the upcoming release of our software NX 8.5.

1853971

'Unbend' fails after 'Rebend' on Flat Solid.

1854107

Siemens PLM believes that the problem you reported where a memory leak was found when creating Offset Curves will be resolved by code changes made to the upcoming release of our software NX 8.5.

1854347

Siemens PLM believes that the problem you reported where there was incorrect translation for German in a CAM dialog will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1854474

Siemens PLM believes that the problem you reported where the Field Table dialog does not properly handle invalid characters in file names will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

1854570

Cannot not use Tracking point with flipped tool.

1855451

Siemens PLM believes that the problem you reported where labels did not transfer to the drawing correctly when a drafting view was created, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1855986

Siemens PLM believes that the problem you reported where an error occurs while importing a part file with the option Import CAM Objects toggled on will be resolved by code changes made to the upcoming release of our software NX 8.5.

1856252

Siemens PLM believes that the problem you reported where a fillet weld cannot be created on the mirrored side of the geometry will be resolved by code changes made to the upcoming release of our software NX 8.5.

1856309

Siemens PLM believes that the problem you reported where the postprocessing could not be interrupted while running Simulation will be resolved by code changes made to the upcoming

Page 17: NX_Errors - 8.5

release of our software NX 8.5. A Work-In-Progress dialog with a "Cancel" option will now be displayed during postprocessing.

1856436

Siemens PLM believes that the problem you reported where NX documentation for the creation of gravity loads does not match the NX user interface will be resolved by code changes made to the upcoming release of our software NX version 8.5.

1856581

Siemens PLM believes that the problem you reported where an extrude feature is not updated when a curve is removed from the section will be resolved by code changes made to the upcoming release of our software NX 8.5. The projected curves created in and after NX 8.5 will be removed from sketch if its parent features get suppressed. We version controlled the fix, so the projected curved created in pre NX 8.5 will behave the same as before.

1856600

Siemens PLM believes that the problem you reported where the time to create Shop Documentation for the same part and template has increased from NX 7.5.3 to NX 7.5.4 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1856623

Siemens PLM believes that the problem you reported where the option names on the Simulation Control Dialog are incorrect in the German version of NX will be resolved by code changes made to the upcoming release of our software NX 8.5.

1856670

Siemens PLM believes that the problem you reported where Groups are not being copied during a view "copy/paste" operation or while exporting a drawing will be resolved by code changes made to the upcoming release of our software NX 8.5.

1856820

Siemens PLM believes that the problem you reported where edge-face forces cause the NX Nastran input deck export function to fail will be resolved by code changes made to the upcoming release of our software NX version 8.5.

1857356

Siemens PLM believes that the problem you reported where using Feature Browser caused an update to occur, having enabled delayed after edit, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1857440

Siemens PLM believes that the problem you reported where co-linear points are not dropped for a Streamline operation will be resolved by code changes made to the upcoming release of our software NX 8.5. The linear moves are not filtered because current rule is to keep grid points, which in this case means drive points. This created a problem in Streamline because for simplicity of operation the original Streamline did not have control over the number of steps per pass and always created 100 steps per pass. In NX 8.5 a fix as been made that added control over the number of steps per pass so in the Streamline drive dialog in the More tab you can set the Cut Step to Tolerances which in this cylinder case will only put one step per pass. A second issue in the pr text said that the NCM lost the inherited clearance plane. This happened because the approach and departure are set to none which means it should not go to clearance plane. A previous bug in NCM allowed these none settings to go to the clearance plane in error, so not going to the clearance plane is the corrected behavior. This has been fixed in NX 8.5.

1857584

Siemens PLM believes that the problem you reported where scaling a body using different X, Y and Z values failed will be resolved by code changes made to the upcoming release of our software NX 8.5.

1857667

Font display "Note / Text window" is incorrect.

18579 Siemens PLM believes that the problem you reported where Negative Part Offset doesn't

Page 18: NX_Errors - 8.5

10 Respect "Cut below Last Range" will be resolved by code changes made to the upcoming release of our software NX 8.5.

1858398

Siemens PLM believes that the problem you reported where the default font shown in the Note Editor dialog did not match that set via "Preferences -> Annotation -> Lettering -> General", will be resolved by code changes made to the upcoming release of our software NX 8.5.

1858471

Siemens PLM believes that the problem you reported where Tool Path Simulation produces inconsistent results for collision checking will be resolved by code changes made to the upcoming release of our software NX 8.5.

1858785

Siemens PLM believes that the problem you reported where "NX 7.5 to JT wrong positioned component after translation" will be resolved by code changes made to the upcoming release of our software, NX 7.5.5, NX 8.0, and NX 8.5.

1859050

Siemens PLM believes that the problem you reported where the Sketcher cannot support snapping with CTRL-drag and CTRL-SHIFT-drag will be resolved by code changes made to the upcoming release of our software NX 8.5.

1859542

Siemens PLM believes that the problem you reported where a WAVE link did not exist in the work part after using assembly constraints and an interpart copy will be resolved by code changes made to the upcoming release of our software NX 8.5.

1859584

Siemens PLM believes that the problem you reported where you see different naming rules for NX CAE solver files in NX 6 through NX 7.5 will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

1859597

Siemens PLM believes that the problem you reported where new extrude bodies get created on the sketch layer and not the work layer when editing a sketch will be resolved by code changes made to the upcoming release of our software NX 8.5.

1859699

Siemens PLM believes that the problem you reported where the ug_inspect switch "-extref" is not mentioned in the documentation will be resolved by code changes made to the upcoming release of our software NX 8.5.

1859803

Siemens PLM believes that the problem you reported where HEM flange not importing global value from for neutral factor from bend table will be resolved by code changes made to the upcoming release of our software NX 8.5.

1860007

Siemens PLM believes that the problem you reported where a transition feature failed to update, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1860251

Siemens PLM believes that the problem you reported where an Edge selected for Trim/Extend was not highlighted unless Show Result was toggled, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1860371

Siemens PLM believes that the problem you reported where after a modeling change the fem has to be updated twice in order to have the spot-welds updated will be resolved by code changes made to the upcoming release of our software NX 8.5.

1860661

Siemens PLM believes that the problem you reported where when working in French, Journal error messages were truncated at the first accented character, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 19: NX_Errors - 8.5

1860673

Siemens PLM believes that the problem you reported where documentation does not explain the interaction between the options "Contact/Tracking" and "Corner Slowdowns" will be resolved by code changes made to the upcoming release of our software NX 8.5.

1860770

Siemens PLM believes that the problem you reported where selection scope settings were limited when using the Point Constructor in the Move Object function will be resolved by code changes made to the upcoming release of our software NX 8.5.

1861055

Siemens PLM believes that the problem you reported where how to control the tolerance for a tolerant curve will be resolved by code changes made to the upcoming release of our software NX 8.5.

1861393

Siemens PLM believes that the problem you reported where there is inconsistent behavior when subtracting an extruded cylinder from a planar sheet and creating a hole in the planar sheet will be resolved by code changes made to the upcoming release of our software NX 8.5.

1861444

Siemens PLM believes that the problem you reported rong Teamcenter Integration Doc for Setup Plotter for TC Integration will be resolved by code changes made to the upcoming release of our software: The problem where documentation for plotting is out-of-date is fixed in release NX 8.5. The "Set Up Plotter for Teamcenter Integration" topic is no longer applicable and is deleted. For information on plotting, see the NX documentation at Home->System Administration->Plotting.

1861572

Siemens PLM believes that the problem you reported where an altrep component that was missing its APPUID named reference object failed to load when its parent was opened in NX (and incorrectly displayed the "excluded reference set" message), will be resolved by code changes made to the upcoming release of our software NX 8.5. Changes are being made in NX 8.5 to reduce the misleading display of the excluded reference set message in general for cases where components fail to load.

1861666

Siemens PLM believes that the problem you reported where "Hide Tool" option in Assembly Cut did not modify the MODEL reference set, will be resolved by code changes made to the upcoming release of our software NX 8.5. The Assemblies Help has been updated to better describe how the Hide Tool option works in the Assembly Cut function. The changes will appear in the NX 8.5 release.

1861711

Siemens PLM believes that the problem you reported where opening a file in Teamcenter reported a message 'An earlier version of the dataset was loaded' will be resolved by code changes made to the upcoming release of our software NX 8.5.

1861943

Siemens PLM believes that the problem you reported where a Cavity Mill operation gouges the part when the Part and the Floor Stock are different will be resolved by code changes made to the upcoming release of our software NX 8.5.

1863092

Siemens PLM believes that the problem you reported where the reference to inter-part expressions is not re-linked when the replacement part is not loaded will be resolved by code changes made to the upcoming release of our software NX 8.5.

1863110

Siemens PLM believes that the problem you reported where translations of NX facets to JT facets, will be resolved by changes made to the upcoming release of our software NX 8.5.

1863116

Creating Probe_Surface_Point suboperation measuring tool changes its orientation.

Page 20: NX_Errors - 8.5

1863204

Siemens PLM believes that the problem you reported where a Part Family Member added as an existing component, bypassing the Part Family Template, was missing when opening the Assembly having imported it into TC, will be resolved by documentation changes made to the upcoming release of our software NX 8.5. Users need to go through the Add component, select template and then select the member. That is how NX makes the association that the component is a Part Family Member (PFM). NX does not know the association between the template part and the PFM when directly selecting the PFM. Adding a PFM directly into an assembly using the Add Component dialog will not store the information needed to do the Auto Generate of missing PFM's. When adding the PFM to the assembly users will need to use Add Component, select the Part Family template and then select the member. It is only then that NX can make the association that this is a PFM. Just directly selecting the PFM member NX will not know the association between the template part and the PFM member.

1863741

Siemens PLM believes that the problem you reported where the members cannot be moved after deleting a Component Array due to remaining constraints will be resolved by code changes made to the upcoming release of our software NX 8.0.1 and NX 8.5.

1863935

Siemens PLM believes that the problem you reported where inherited PMI was mis-located on a drawing sheet, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1864028

Siemens PLM believes that the problem you reported where material data exported was missing metadata will be resolved by code changes made to the upcoming release of our software NX 8.5. Please note: the xml files provided are missing key information that enables NX to properly import and display the materials. The problem with export has been fixed but the user will need to re-export materials.

1864068

Siemens PLM believes that the problem you reported where the NX 8 documentation showed an incorrect message about deprecated SelectObject methods will be resolved by code changes made to the upcoming release of our software NX 8.5.

1864076

Siemens PLM believes that the problem you reported where the documentation contains a confusing statement about the InterpartSelection property of Collector blocks in the BlockStyler will be resolved by code changes made to the upcoming release of our software NX 8.5.

1864107

Getting an Internal Error when trying to create a new Milling Tool in NX 8.

1864169

Siemens PLM believes that the problem you reported where depending on feature type the "Edit with Rollback" has different results will be resolved by code changes made to the upcoming release of our software NX 8.5.

1864204

Changing the global depth of cut does not change range depth of cut.

1864288

Siemens PLM believes that the problem you reported where a Journal for Onestep Unform fails with 'No object found with this name' will be resolved by code changes made to the upcoming release of our software NX 8.5.

1864323

Siemens PLM believes that the problem you reported where the IPW for blank 'auto block' is in the wrong location will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1864347

Signal 11 Error during Create Tool of any type - license file issue.

Page 21: NX_Errors - 8.5

1864489

Siemens PLM believes that the problem you reported where "Modeler error:archived attribute defns do not match current" while opening part, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1864566

Siemens PLM believes that the problem you reported where you can't Rebend after Unbend, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1864631

Siemens PLM believes that the problem you reported where the NX documentation for the Routing application is not updated for use with Teamcenter9 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1864893

Siemens PLM believes that the problem you reported where turning on "Cut Between Levels" causes NX to hang when the operation is generated in a Zlevel Profile operation will be resolved by code changes made to the upcoming release of our software NX 8.5.

1864994

Siemens PLM believes that the problem you reported where the Rebend fails after Unbend will be resolved by code changes made to the upcoming release of our software NX 8.5.

1865035

Siemens PLM believes that the problem you reported where the Rebend creates an incorrect body will be resolved by code changes made to NX 8.5. To implement the fix, the Unbend feature needs to be updated with "Edit --> Feature --> Playback" in that version and then the Rebend should work correctly.

1865119

Cannot edit or create a cutting tool -- internal error.

1865204

Close button in the Menu Bar will close all Parts.

1865649

Siemens PLM believes that the problem you reported where adding an object to a group fails with "One of the invalid characters @!*? was entered" when a "<" or ">" appears in the group name will be resolved by code changes made to NX 8.5.

1865763

Siemens PLM believes that the problem you reported where you were seeing incorrect ISV motion when using the Corner option 'Extend', with Cutcom and Contact Data turned on will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1865835

Siemens PLM believes that the problem you reported where creating a Boolean feature took twice as long in NX 7.5.4 and later, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1866033

Siemens PLM believes that the problem you reported where the Documentation for NX CAM ISV is not correct will be resolved by code changes made to the upcoming release of our software fixed in NX 8.5. Documentation has been revised and updated.

1866133

Siemens PLM believes that the problem you reported where Assembly Constraints for Routing Assemblies was incompletely documented, will be resolved by code changes made to the upcoming release of our software NX 8.5. The Align & Rotate options available in the Assembly Constraints dialog box have been added to the Assemblies help with descriptions.

1866491

Unable to get UV Raster visible in NX4 created view.

Page 22: NX_Errors - 8.5

1866965

Siemens PLM believes that the problem you reported where Sketch update performance was slow will be resolved by code changes made to the upcoming release of our software NX 8.5.

1867011

Siemens PLM believes that the problem you reported where generating a Turning operation results in an "Interrupt" error will be resolved by code changes made to the upcoming release of our software NX 8.5, NX 6.0.5 MP11 and NX 7.5.5 MP2.

1867088

Siemens PLM believes that the problem you reported where documentation showed the wrong path for the 'cgm2pdf' utility will be resolved by changes made to the Command Line Utilities help in the upcoming release of our software NX 8.5. The path has been updated as follows: The cgm2pdf utility is located in your UGII_BASE_DIR/nxplot/bin/pdf directory.

1867103

Siemens PLM believes that the problem you reported where a Move Object operation using CSYS to CSYS transformation failed will be resolved by code changes made to the upcoming release of our software NX 8.5.

1867148

Siemens PLM believes that the problem you reported where a view, whose active sketch was finished is reset as the active sketch view, with sketch mode active, on restarting the Drafting application, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1867301

Siemens PLM believes that the problem you reported where the Knowledge Fusion documentation for the function ug_createInstance needed to supply additional information, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

1867540

Siemens PLM believes that the problem you reported where Gouge Check reports false gouges when negative part stock is used on a 5 axis cut will be resolved by code changes made to the upcoming release of our software NX 8.5.

1867976

Siemens PLM believes that the problem you reported where a CSE TNC530 Parse Error is reported on a Sinumerik non-motion cycle will be resolved by code changes made to the upcoming release of our software NX 8.5.

1868025

Siemens PLM believes that the problem you reported where Resize Bend Angle fails with "Unable to create body", will be resolved by code changes made to the upcoming release of our software NX 8.5.

1868310

Siemens PLM believes that the problem you reported regarding unreliable behavior when using the SB Rebend feature, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1868609

Siemens PLM believes that the problem you reported where a Knowledge Fusion ui_comp_expression block sometimes failed to rename the linked expression when the Name parameter was changed, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1868778

Siemens PLM believes that the problem you reported where editing the face measurement causes an error, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1868828

Siemens PLM believes that the problem you reported where users were unable to create a PCF (or JT) file using "Send to Package file", will be resolved by code changes made to the upcoming release of our software NX 8.5.

18690 Siemens PLM believes that the problem you reported where you experience a performance

Page 23: NX_Errors - 8.5

66 issue when assigning a Part Attribute will be resolved by code changes made to the upcoming release of our software NX 8.5.

1869258

NXApplication feature has incorrect display in the part navigatorfeature.

1869552

Siemens PLM believes that the problem you reported where inserting a new custom symbol continues to display a previously selected symbol, unless the new symbol is double clicked, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1869600

Siemens PLM believes that the problem you reported where a Feature Control Frame could not be positioned as desired when using vertical text will be resolved by code changes made to the upcoming release of our software NX 8.5.

1870111

Siemens PLM believes that the problem you reported where a load applied to a parabolic edge may not have the correct orientation will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

1870150

Siemens PLM believes that the problem you reported where using F8 to orient work view was not working as described in the documentation, will be resolved by documentation changes made to the upcoming release of our product NX 8.5. The Help Documentation has been updated in the following section: NX 8.5 -> Fundamentals -> Viewing and rendering -> Orienting views -> Snap to a view using keyboard shortcuts.

1870832

Siemens PLM believes that the problem you reported where Certain BodyDraft impossible will be resolved by code changes made to the upcoming release of our software NX 8.5. To see the results the DraftBody feature has to be created new. In the edit of existing DraftBody feature this fix will not be present.

1871129

Siemens PLM believes that the problem you reported where the memory requirement is incorrect will be resolved by code changes made to the upcoming release of our software NX 8.5.

1871202

Siemens PLM believes that the problem you reported where a face blend in a particular part file failed to update will be resolved by code changes made to the upcoming release of our software NX 8.5.

1871277

Knowledge Fusion Customer Defaults not documented.

1871371

Siemens PLM believes that the problem you reported where Change of expression value, model update, cause save to fail will be resolved by code changes made to the upcoming release of our software NX 8.5. In this PR there were different issues. The PR part "5288006_1_0.prt" has got corrupted somehow - Instanced Simple Hole(750), Instanced Counterbore Hole(752) and Instanced Threaded Hole(756) features were corrupted. Development have corrected the part in NX 7.5.4. (The corrected part is uploaded under the name "5288006_1_0_NX754_CorrectedPart.prt" in the PR data tool). This corrected part has issues with Thread Feature which has been fixed in NX 8.5. For older parts, user needs to do part cleanup before performing the PR steps.

Page 24: NX_Errors - 8.5

1871560

Siemens PLM believes that the problem you reported where feature's curve direction was getting flipped, was found to be related to Offset Curve feature and will be resolved by code changes made to the upcoming release of our software NX 8.5.

Note: The existing offset curve feature in the uploaded part will have to be recreated in NX 8.5 in order to get the desired behavior as the existing offset curve feature will not have any effect of the fix and will continue to update the same way.

1871602

Siemens PLM believes that the problem you reported where Intersection curve fails will be resolved by code changes made to the upcoming release of our software NX 8.5.

1871810

Siemens PLM believes that the problem you reported where the strike through text formatting of a Tabular Note was lost, having editing it in Excel, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1871816

Siemens PLM believes that the problem you reported where the wave browser buttons were missing will be resolved by code changes made to the upcoming release of our software NX 8..5.

1871917

Siemens PLM believes that the problem you reported where a datum feature symbol that is associated to the extension line of a perpendicular dimension AND aligned to its arrow swaps extension lines when placed will be resolved by code changes made to the upcoming release of our software NX 8.5.

1871925

Why is a direct sketch always activated?

1872078

Siemens PLM believes that the problem you reported where it was not possible to select a folder from the distributed file system in Translator dialogs will be resolved by code changes made to the upcoming release of our software NX 8.5 with JRE 1.7.

1872436

Siemens PLM believes that the problem you reported where Sheet Metal Bend using Extended Relief cause incorrect result will be resolved by code changes made to the upcoming release of our software NX 8.5.

1872451

Not possible to set selection Filter to Entire Assembly within Move Object.

1872453

Siemens PLM believes that the problem you reported where the StudioXformBuilderEx did not return an NXObject when Commit() was called will be resolved by code changes made to the upcoming release of our software NX 8.5.

1872600

Split Body should leave the result bodies at the layer from target body.

1872645

Siemens PLM believes that the problem you reported where there were duplicate references to the functionality of the F4 key, is fixed in the NX 8.5 help documentation. The Keyboard Accelerators help topic in the NX Interface help is updated with the following: View the Information window - Press Ctrl+Shift+S.

1872777

Siemens PLM believes that the problem you reported where block UI dialogs were right justified for the first parameter field only, when the value was created from an expression, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1873030

Siemens PLM believes that the problem you reported where "7544MP4 cannot tessellate deformable feature, while NX3053MP06 does" will be resolved by code changes made to the

Page 25: NX_Errors - 8.5

upcoming release of our software, NX 8.5.

1873170

Siemens PLM believes that the problem you reported where android gmail app not syncing mail on schedule will be resolved by code changes made to the upcoming release of our software NX 8.5.

1873440

Siemens PLM believes that the problem you reported where a Curve on Surface feature failed with the alert "Curve is out of tolerance with the faces", will be resolved by code changes made to the upcoming release of our software NX 8.5.

1873520

Siemens PLM believes that the problem you reported where a Tosca Structure Error is obtained when using Nastran64l.exe will be resolved by code changes made to the upcoming release of our software NX Nastran version 8.5.

1873920

Siemens PLM believes that the problem you reported where an Internal Error was raised printing a drawing when a shaded View was off the drawing, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1874138

Siemens PLM believes that the problem you reported where LS-dyna results are not post-processed correctly will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

1874188

Siemens PLM believes that the problem you reported where a 4-Axis Wire EDM wire engage direction vector is incorrect will be resolved by code changes made to the upcoming release of our software NX 8.5.

1874485

Siemens PLM believes that the problem you reported where the Help Documentation correction topic "Save As Precise Assembly" is not correct will be resolved by code changes made to the upcoming release of our software NX 8.5.

1874651

Siemens PLM believes that the problem you reported where where the command "Make Datums External" places datums on the work layer, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1874949

Siemens PLM believes that the problem you reported where new boundary conditions can not be created if a boundary condition is selected in the simulation navigator will be resolved by code changes made to the upcoming release of our software NX version 8.0.1

1874996

Siemens PLM believes that the problem you reported where the sorting of the Revision Column in the TC Navigator in NX behaves differently than My Navigator in TC, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1875085

Siemens PLM believes that the problem you reported where a part file used could not be opened, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1875279

TURNING: Operations have wrong tool paths starting NX 6.0.5 MP8.

1875291

Siemens PLM believes that the problem you reported where a "MOM_TCL" error during simulation caused a UI problem will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 26: NX_Errors - 8.5

1875356

Siemens PLM believes that the problem you reported where Feature update worked differently when UGII_SMP_ENABLE=1 is set versus when it is not set will be resolved by code changes made to the upcoming release of our software NX 8.5.

1875369

Siemens PLM believes that the problem you reported where ID Symbols associated to dimensions did not maintain their position when the drawing view was moved, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1875669

Siemens PLM believes that the problem you reported where a rapid move collides with the IPW will be resolved by code changes made to the upcoming release of our software in release NX 8.5.

1875840

Siemens PLM believes that the problem you reported where Wedm damaged the Workpiece during a Retract of multiple Paths will be resolved by code changes made to the upcoming release of our software NX 8.5.

1875878

Siemens PLM believes that the problem you reported where the feature attributes from the UDF definition feature in the UDF part were not copied to a UDF, inserted using the Knowledge Fusion class ug_udfs, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1875988

Siemens PLM believes that the problem you reported where the Part Save History documentation did not explain that the first entry in the report is the currently loaded version, and the second entry is the NX version where the part was last saved, will be resolved by changes made to the documentation of the upcoming release of our software NX 8.5.

1876130

Siemens PLM believes that the problem you reported where face translucency values were incorrect after a subtract operation, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1876233

Siemens PLM believes that the problem you reported where setting the customer default for iprt naming does not work as expected will be resolved by code changes made to the upcoming release of our software NX 8.0.2 and later.

1876531

Siemens PLM believes that the problem you reported where Check-Mate fails the Check Master Model Drawing test, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1876797

Siemens PLM believes that the problem you reported where Associative Datum Axis not visible on Screen or in Part Navigator when created will be resolved by code changes made to the upcoming release of our software NX 8.5.

1876816

Siemens PLM believes that the problem you reported where when changing the material label in the "manage material" window for a copied material, this label is only updated when closing and reopening the window will be resolved by code changes made to the upcoming release of our software NX 8.5.

1876819

Siemens PLM believes that the problem you reported where SHELL SECTION cards were not being written to ABAQUS for AFEM models will be resolved by code changes made to the upcoming release of our software NX 8.5.

1876933

Not possible to select Folder from Distributed File System in TC Rich client.

18770 Siemens PLM believes that the problem you reported where the tool and target do not form a

Page 27: NX_Errors - 8.5

60 complete intersection, will be resolved by code changes made to the upcoming release of our software NX 8.5. The problem could not be fixed in NX 7.5, for it is a Parasolid problem, there is no plan to integrate new Parasolid into NX 7.5.

1877092

Wrong translation into German of "Number" in the Teamcenter NX Navigator.

1877149

Siemens PLM believes that the problem you reported where the tool axis definition 'Toward' and 'Away From a Point' is not associative to the point definition will be resolved by code changes made to the upcoming release of our software NX 8.5. Other tool axis definitions that are geometry based will be considered for NX 9.

1877161

Siemens PLM believes that the problem you reported where a severe issue occurs with NX Nastran licensing in NX Motion Flexible Body will be resolved by code changes made to the upcoming release of our software NX NASTRAN Version 8.5.

1877163

Siemens PLM believes that the problem you reported where NX8 crashes when renaming an inactive load will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

1877231

Siemens PLM believes that the problem you reported where the user is unable to parallel generate a Teamcenter Manifestation in NX 7.5.4, NX 7.5.5 and NX 8 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1877239

Siemens PLM believes that the problem you reported where Gouge Check returns gouge warnings in a Planar Milling operation with just Part Stock defined will be resolved by code changes made to the upcoming release of our software NX 8.5.

1877307

Siemens PLM believes that the problem you reported where the NXOpen.Assemblies.ProductInterface > Collection > CreateObjectBuilder had a hard-coded default that prevented the ability to obtain the current WaveSetting rule in the part, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1877340

Siemens PLM believes that the problem you reported where Paste does not work for "Copy Original Curve" will be resolved by code changes made to the upcoming release of our software NX 8.5.

1877351

The problem where NX Macro MULTI_SELECT command not accepting whitespaces, is fixed in release NX 8.5.

1877454

Siemens PLM believes that the problem you reported where a Variable Contour with Surface Area drive method operation had spikes will be resolved by code changes made to the upcoming release of our software NX 8.5.

1877498

Siemens PLM believes that the problem you reported where the color is not inherited from Target Sheet when Sewing Sheets Copied to Layer will be resolved by code changes made to the upcoming release of our software NX 8.5.

1877585

Siemens PLM believes that the problem you reported where the documentation for the required file location of User Defined Block files was not clear will be resolved by code changes made to the upcoming release of our software NX 8.5.

1877655

Siemens PLM believes that the problem you reported where the given Stratpoint will not coming out in Planar-Mill Operation will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 28: NX_Errors - 8.5

1877682

Siemens PLM believes that the problem you reported where there wer no results for 3D elements in the report for 3D+1D elements model will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

1877764

Siemens PLM believes that the problem you reported where Part cleanup deletes the leaders of legacy surface finish symbols, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1877812

Insert->Operation appends object to end of list rather than inserting.

1877848

Siemens PLM believes that the problem you reported where split solid tool doesn't inherit the color faces will be resolved by code changes made to the upcoming release of our software NX 8.5.

1877851

Siemens PLM believes that the problem you reported where additional documentation is needed for the attribute REFERENCE_COMPONENT will be resolved by code changes made to the upcoming release of our software NX 8.5.

1877897

Siemens PLM believes that the problem you reported where a Feature Parameter based dimension, placed in view modified using View Break function, was incorrectly placed on the dimensioned features original position, will be resolved by code changes made to the upcoming release of our software NX 8.5. Features need a view to be inherited, which would require slave views to be listed in the dialog, as the slaves contain all geometry. Slaves cannot be accessed directly, so broken views have to be filtered out. To inherit features, suppress view breaks first.

1878026

Siemens PLM believes that the problem you reported where PMI_section_cannot be properly edited will be resolved by code changes made to the upcoming release of our software NX 8.5.

1878031

PR-06585475 is not solved.

1878544

Siemens PLM believes that the problem you reported where the documentation for Mirror Certification was incomplete for the the "Back Angle (A40)" and "Seat Track Travel (TL23)" inputs, will be resolved by documentation changes made to the upcoming release of our software NX 8.5. A topic titled "Mirror Certification Wizard - Driver Position" has been updated to add descriptions for Back Angle (A40) and Seat Track Travel (TL23).

1878561

Siemens PLM believes that the problem you reported where the documentation for the Font Line Mapping was wrong, will be resolved by documentation changes made to the upcoming release of our software NX 8.5. The modified content under Home > Data translation > Data Exchange > DXF/DWG translator overview > Import > Line font mapping topic now reads as follows: If the line display is incorrect with a given line font mapping, correct it by setting the line scale factor in the line font mapping text file. You should decide the actual value (such as, 0.5) through a heuristic approach. EXPORT: "UF_OBJ_FONT_CENTERLINE"="CENTER",.05.

1878736

Siemens PLM believes that the problem you reported where the ability to import simulation entities on multiple component FEM's, at once in an assembly fem context, in NX 8 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1879109

Siemens PLM believes that the problem you reported where a hole is not detected and is missing from the hole table will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 29: NX_Errors - 8.5

1879193

Siemens PLM believes that the problem you reported where creating a Detail View resulted in part features being duplicated, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1879222

Siemens PLM believes that the problem you reported where an Internal error was raised adding Weld Points using the Mirror Method, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1879281

Siemens PLM believes that the problem you reported where it was not possible to enter any data into any text fields of the Welcome Background Web Page, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1879594

Siemens PLM believes that the problem you reported where the WEDM face selection order and Material Side that are used will cause a tool axis gouge will be resolved by code changes made to the upcoming release of our software NX 8.5.

1879600

Siemens PLM believes that the problem you reported where the WEDM INTERNAL_TRIM operation type gouges the part on the Lead In Point will be resolved by code changes made to the upcoming release of our software NX 8.5.

1879618

Siemens PLM believes that the problem you reported where "color of the part will not inherited in sim model" is fixed in NX 8.5 ip19. will be resolved by code changes made to the upcoming release of our software NX version 8.5.

1879849

Siemens PLM believes that the problem you reported where the TC preference TC_NX_ANT_Column_Config did not display values for user-defined properties in the NX Assembly Navigator, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1879886

Siemens PLM believes that the problem you reported where a Flat Pattern reports the error: "Unable to create body" when editing an offset value of a Datum Plane, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1879932

Siemens PLM believes that the problem you reported where a "Date" attribute of a part cannot be added to a cell in a tabular note will be resolved by changes made to NX 8.5. This attribute type is not supported for import at this time and the limitation will be added to the Help documentation.

1880063

Siemens PLM believes that the problem you reported - where Default Ascii-Library Tools are not usable in NX after retrieving from the Library - will be resolved by code changes made to the upcoming release of our software NX 8.5.

1880801

Siemens PLM believes that the problem you reported where hidden member features became unembedded when a feature set created using the Knowledge Fusion class ug_feature_set was suppressed, and then unsuppressed, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1880894

Siemens PLM believes that the problem you reported where documentation is needed for mapping the C type pointer to C# type structure will be resolved by code changes made to the upcoming release of our software NX 8.5.

1881006

Siemens PLM believes that the problem you reported where in NX 8 the user was unable to create dimensions on 2d entities, receiving the error: "Curve is wrong type", will be resolved by code changes made to the upcoming release of our software NX 8.5. The fix has also been submitted for a future maintenance pack for NX 8.0.1.

Page 30: NX_Errors - 8.5

1881030

Siemens PLM believes that the problem you reported where you were unable to translate a STEP file with NX 8 reporting: "Error number: 1", will be resolved by code changes made to the upcoming release of our software NX 8.5.

1881146

Siemens PLM believes that the problem you reported with projected distance measurement during animation, where the vector needs to be transformed has been addressed in NX 8.5 phase 12.

1881368

Siemens PLM believes that the problem you reported where Icons for Flip Horizontally and Flip Vertically for Custom Symbols are mixed up will be resolved by code changes made to the upcoming release of our software NX 8.5.

1881566

Siemens PLM believes that the problem you reported where Inconsistent behavior positioning Sheet Metal flange from endpoint with sketch will be resolved by code changes made to the upcoming release of our software NX 8.5.

1881592

Siemens PLM believes that the problem you reported where drawing files open always modified even though they where just saved, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1881627

Siemens PLM believes that the problem you reported where the error "UPDATE/DELETE has gone through too many iterations appears during drawing update will be resolved by code changes made to NX 8.5.

1881656

Siemens PLM believes that the problem you reported where an attempt was made to check out the STUDIO_VISUALIZE license per-object rather than per-view will be resolved by code changes made to the upcoming release of our product NX, Version 8.5 phase 19.

1881976

User Exit ufrcp not called while adding base view from part as of NX 6.

1882004

Siemens PLM believes that the problem you reported where the screen annotation (header information) displayed for the deformation results is incorrect will be resolved by code changes made to the upcoming release of our software NX 8.5.

1882061

Siemens PLM believes that the problem you reported where after resizing the bend radius, a sheetmetal part is unable to be flattened will be resolved by code changes made to the upcoming release of our software NX 8.5.

1882197

Siemens PLM believes that the problem you reported where a file fails to open with the message "Incorrect Object for this Operation", will be resolved by code changes made to the upcoming release of our software NX 8.5. The supplied part had 14 corrupt ordinate dimensions on sheet 'tasspunzone'. The ordinate dimensions are corrupt because they had no associated ordinate origin dimension. The corrupt dimensions have been deleted and a repaired part can be provided upon request to GTAC. Starting with NX 8.0.2, any pre-NX 4 ordinate dimensions that are corrupt because they do not have an associated ordinate origin will be deleted when the part is loaded so the part can be successfully loaded.

1882275

Siemens PLM believes that the problem you reported where searching a part number using a wild card returns two choices, one of which can't be opened, will be resolved by code changes made to the upcoming release of our software NX 8.0.

1882432

Siemens PLM believes that the problem you reported where OPSTOP - Event disturbs the Toolpath (Wire Axis oscillate) will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 31: NX_Errors - 8.5

1882915

Siemens PLM believes that the problem you reported where Pre-delete information was confusing regarding "Missing - features", will be resolved by code changes made to the upcoming release of our software NX 8.5.

1883218

Siemens PLM believes that the problem you reported where view not out of date when add Symbolic Threads to master model prt file will be resolved by code changes made to the upcoming release of our software NX 8.5.

1883493

Siemens PLM believes that the problem you reported where new surface finish returns bad data using the function UF_DRF_ask_ann_data will be resolved by code changes made to the upcoming release of our software NX 8.5. This user function will raise an error for New drafting surface finish object. The .NET function NXOpen::Annotations::ComponentData can be used in the current version. To get the ComponentData of any Annotation object, use it as an argument to the Part's AnnotationManager's method CreateComponentData.

1883535

Siemens PLM believes that the problem you reported where additional documentation was needed to describe the mapping of KF Frames to NX Open, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

1883606

Siemens PLM believes that the problem you reported where Title block aspect is improperly changed after populating it will be resolved by code changes made to the upcoming release of our software NX 8.5.

1883864

Siemens PLM believes that the problem you reported where the broken documentation links in NX 8 .NET Reference for UFMtx and UFVec classes will be resolved by code changes made to the upcoming release of our software NX 8.5 IP14.

1883909

Siemens PLM believes that the problem you reported where "reference set information fails to show more than 30 characters of component name" will be resolved by code changes made to the upcoming release of our software NX 8.5.

1884056

Siemens PLM believes that the problem you reported where reordering a feature in the Part Navigator using drag and drop into other feature groups, the order of the feature groups automatically changes, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1884152

Siemens PLM believes that the problem you reported where the addition of a Mirror feature produced an incorrect volume calculation, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1884280

Siemens PLM believes that the problem you reported where UF_DRF_create_label() did not work properly will be resolved by code changes made to the upcoming release of our software NX 8.5.

1884494

Internal error when opening specific .afm files...

1884620

Siemens PLM believes that the problem you reported where when updating a 1D mesh by de-selecting and re-selecting and edge that causes a mesh direction change will be resolved by code changes made to the upcoming release of our software NX 8.5.

1884873

Siemens PLM believes that the problem you reported where CSE shows empty Lines when "mom_o_buffer" is set to "" will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 32: NX_Errors - 8.5

1884929

Siemens PLM believes that the problem you reported where an undesirable faceted display could not be refreshed, having disabled the "Highlight Original" Selection Preference after highlighting the geometry, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1884995

Siemens PLM believes that the problem you reported where tolerances assigned to a sketch in modeler were not applying those tolerances in Drafting will be resolved by code changes made to NX 8.5.

1885030

Wrong trnaslation of "Number" in TC Navigator.

1885087

Interoperability using Solid Edge ST4 & CAM Express 8.0.

1885094

Siemens PLM believes that the problem you reported where the time to update a Swept feature was significantly longer when the "% Arc Length" was greater than zero, will be resolved by code changes made to the upcoming release of our software NX 8.5 The original problem occurred when the profile section was defined at the middle of the sweep (instead of at the end). Pre NX 8.5 performs different code at first, a two side sweeping then add a additional rebuild... In NX 8.5 we enhanced the Swept with a new option called "Split output along the guide". With this new option enabled large surfaces no longer need to be rebuilt, therefore, the performance is improved.

1885137

Siemens PLM believes that the problem you reported where a Unite using two intersecting solids failed will be resolved by code changes made to the upcoming release of our software NX 8.5.

1885178

Relations Browser not working when starting NX with the wrong bundle.

1885277

Siemens PLM believes that the problem you reported where the Tool is gouging during a transfer move if the stepover is set to 'On Plane' will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1885382

Siemens PLM believes that the problem you reported where the Redefine Constraints option "Preview Component in Main Window" is always toggled OFF and is not recorded in Dialog Memory, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1885404

Switching to Drafting always activates last Sketch view.

1885448

Siemens PLM believes that the problem you reported where element forces and moments are not recovered properly for cbush elements will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

1885574

Siemens PLM believes that the problem you reported where the Hole Table was including blended extrude corners, as of NX 7.5.4, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1885614

Siemens PLM believes that the problem you reported where a Pattern Feature had an incorrect result when using the Variational option will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 33: NX_Errors - 8.5

1885713

Siemens PLM believes that the problem you reported where "DIMENSION" was misspelled as "DIMSESION" in the reference for mqc_askObjects1 in the Knowledge Fusion Quick Reference for NX 7.5 Documentation will be resolved by code changes made to the upcoming release of our software NX 8.5.

1885871

Siemens PLM believes that the problem you reported where updating an NX 5 mirror feature will flip the draft direction as of NX 7.5 will be resolved by code changes made to the upcoming release of our software NX 8.5. The fix in NX 8.5 requires that the pre-NX 8.5 Divide Face feature in the part is replaced with an NX 8.5 Divide Face feature.

1886121

Loft Flange with arcs.

1886205

Siemens PLM believes that the problem you reported where the documentation did not clearly state that users should not use the unload option "IMMEDIATELY" in an application that has UI components will be resolved by code changes made to the upcoming release of our software NX 8.5.

1886210

Siemens PLM believes that the problem you reported where when using promoted data, the geometry was incorrectly positioned, will be resolved by changes made to the upcoming release of our software NX 8.5.

1886211

Siemens PLM believes that the problem you reported where "DXF Import" imported all lines with a normal width, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1886231

Siemens PLM believes that the problem you reported where there was no remark in the NXOpen PartFamilyManager reference documentation explaining how to obtain a class instance will be resolved by code changes made to the upcoming release of our software NX 8.5.

1886273

Siemens PLM believes that the problem you reported where Incorrect tolerance values in lim_fits_table_data_iso_1 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1886546

Siemens PLM believes that the problem you reported where switching from a component fem to the afem causes internal errors will be resolved by code changes made to the upcoming release of our software NX version 8.5.

1886547

Siemens PLM believes that the problem you reported where NX hangs if 'undo' is used after manually creating an element has been resolved by code changes made to the upcoming release of our software NX 8.5.

1886565

Siemens PLM believes that the problem you reported where Export of a single part with drawing stored in Teamcenter 8.3 will be resolved by code changes made to the upcoming documentation release of our software NX 8.5.

1886585

Parallel Generate doesn't work with manifestation.

1886771

Naming rule from TC not functional in NX.

1886794

Siemens PLM believes that the problem you reported where it is not possible to load multiple instances of an ISV device will be resolved by code changes made to the upcoming release of

Page 34: NX_Errors - 8.5

our software NX 8.5.

1886848

Siemens PLM believes that the problem you reported where Assembly saved in Design simulation does allow Assembly constraints creation will be resolved by code changes made to the upcoming release of our software NX 8 and 8.5.

1886868

Cavity Mill, IPW Collision with Lowest safe Z.

1886883

Siemens PLM believes that the problem you reported where a DXF translation failed causing the NX session to hang on Mac OS, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1886900

Siemens PLM believes that the problem you reported where outputs of non-associative Sketch curve offsets were not added to the active sketch group, and they did not get the right names, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1886961

Siemens PLM believes that the problem you reported where the wrong form is presented when pre-selecting a boundary condition and then trying to create a new boundary condition will be resolved by code changes made to the upcoming release of our software NX 8.5.

1887123

Siemens PLM believes that the problem you reported where Different Value for Merge Distance gives different Results (damaging Workpiece) will be resolved by code changes made to the upcoming release of our software NX 8.0.3.

1887301

Chamfer wrongly mirrored.

1887345

Offset face in NX 8.0.1.5 fails.

1887419

Siemens PLM believes that the problem you reported where an "Out of Memory" error appears when trying to insert a User Defined Feature will be resolved by code changes made to NX 8.5.

1887678

Siemens PLM believes that the problem you reported where the Recurdyn solver accepts conflicting mechanisms will be resolved by code changes made to the upcoming release of our software NX Motion Simulation, version 8.5.

1887679

Reattach Sketch - dimension Origin does not change.

1887685

Siemens PLM believes that the problem you reported where NX PMI with large text resulted in the .jt file not being able to display this PMI, will be resolved by changes made to the upcoming release of our software NX 8.5.

1887736

Siemens PLM believes that the problem you reported where Sweep Along Guide creates sheet body when type was specified as Solid will be resolved by code changes made to the upcoming release of our software NX 8.5. Please recreate the sweep along guide again: Section Curve: the lines from rectangle curve (connected curve rule) Guide Curve: the magenta-color curves (Tangent curve rule) Body Type: solid.

1887978

Siemens PLM believes that the problem you reported where NX crashed during a 2D meshing operation will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 35: NX_Errors - 8.5

1888033

Siemens PLM believes that the problem you reported where strange behavior is noticed for dependent dof distribution on an element edge to element face connection will be resolved by code changes made to the upcoming release of our software NX version 8.5.

1888120

Siemens PLM believes that the problem you reported where the Body Measurement associativity becomes broken will be resolved by code changes made to the upcoming release of our software NX 8.5. In NX 7.5, the Body Measurement would not have a broken link, but would often miscalculate its results. This is fixed in NX 8.0 by breaking the link when NX could not reliably recalculate the values. This occurred due to context problems with occurrences. In NX 8.5, this context problem has been fixed by using smart collectors. New Body Measurements created in NX 8.5 will no longer have this problem. Old Body Measurements can be fixed in NX 8.5 by converting them to the new data model by editing the feature and selecting OK. In NX 8.0, it is suggested to use the available work-around.

1888200

Siemens PLM believes that the problem you reported where mesh control display settings are not applied properly will be resolved by code changes made to the upcoming release of our software NX 8.5. Mesh control preferences form in FEM is supposed to show the current settings stored in that FEM instead it was showing dialog memory settings. This bug is fixed in NX 8.5. Also, reset on mesh control preferences dialog will load customer defaults starting from NX 8.5.

1888266

Siemens PLM believes that the problem you reported where Drawing Views were disappearing after performing a Part Cleanup, will be resolved by code changes made to the upcoming release of our software NX 8.5. The fix will also be included in the next available maintenance packs for NX 7.5.5 and NX 8.0.2.

1888337

Siemens PLM believes that the problem you reported where the measure tool in surface-to-surface glue returned a minimum distance of 0 for all measurements will be resolved by code changes made to the upcoming release of our software NX 8.5.

1888405

Siemens PLM believes that the problem you reported where a Drawing is always out of date, even after updating all the view in the sheet, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1888473

Siemens PLM believes that the problem you reported where the NX Nastran parameter 'MODTRK' is displayed and exported as 'MODETRK' will be resolved by code changes made to the upcoming release of our software NX 8.5.

1888507

Siemens PLM believes that the problem you reported where "Transform -> Mirror -> Copy" was not working as expected using the supplied part file, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1888641

Siemens PLM believes that the problem you reported where the Quick Path is missing from the product but still appears in the documentation will be resolved by code changes made to the upcoming release of our software NX 8.5.

1888678

Siemens PLM believes that the problem you reported where Sketch Points converted to Reference did not updated correspondingly in a Linked Sketch, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1888700

Siemens PLM believes that the problem you reported where the plastic strain results are null on the bottom shell will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

Page 36: NX_Errors - 8.5

1888795

Siemens PLM believes that the problem you reported where the Assemblies Help had no information about several options on the Assembly tab of the Component Properties dialog box, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1888801

Siemens PLM believes that the problem you reported where the Mass Property Measurement did not change its displayed value when the Analysis Units were changed, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1888869

Siemens PLM believes that the problem you reported where the f(x) function builder's Browse button incorrectly enabled filtering for "*.prt" when specifying the first parameter for the Knowledge Fusion function ug_excel_open_file, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1888877

Siemens PLM believes that the problem you reported where model setup check takes too long will be resolved by code changes made to the upcoming release of our software NX 8.5.

1888893

Siemens PLM believes that the problem you reported where opening a sim file linked to assyfem takes too much time (50min) will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

1889037

Siemens PLM believes that the problem you reported where the NXOpen Remote Processes documentation needed correction will be resolved by code changes made to the upcoming release of our software NX 8.5.

1889052

Siemens PLM believes that the problem you reported where slow Gouge check performance for a rotated tool axis or MCS is not documented, is fixed in NX 8.5. The following tip was added to the docs ... Manufacturing General -> Operation Navigator -> Operation Navigator commands -> Tool Path commands: The gouge check is faster when the tool axis is aligned, in either the positive or negative direction, along the main X, Y, or Z axis. Rotating the tool axis or the MCS increases the calculation time.

1889144

Siemens PLM believes that the problem you reported where it was not possible for an NX Open API application to find the PatternFeature that creates a given edge, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1889356

Siemens PLM believes that the problem you reported where a Section Curve does not update correctly, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1889468

Siemens PLM believes that the problem you reported where Block_Template Output in own Post is limited to 200 Characters will be resolved by code changes made to the upcoming release of our software NX 8.5.

1889629

Siemens PLM believes that the problem you reported where you were getting a Parse error after reading '50 TCH PROBE 0.1 PLAN DE' will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1889645

Siemens PLM believes that the problem you reported where lengthy updates occurred when re-specifying the View Break Direction with multiple View Breaks in a view, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1889974

Siemens PLM believes that the problem you reported where importing a part file containing a note in a group did not display the note will be resolved by code changes made to the upcoming release of our software NX 8.0.2 and NX 8.5.

Page 37: NX_Errors - 8.5

1890044

Siemens PLM believes that the problem you reported where all CSYS in the model are exported during a subset export will be resolved by code changes made to the upcoming release of our software NX 8.5. With the fix, only the CSYS referenced by the entities part of the subset export end up in the Nastran deck.

1890093

Siemens PLM believes that the problem you reported where the 'cad construction geometry' settings within 'file, utilities, customer defaults, simulation, general, fe model create' are not honoured when a .fem file is created will be resolved by code changes made to the upcoming release of our software NX 8.5.

1890199

Siemens PLM believes that the problem you reported where rotating the MCS causes some operations to go out-of-date will be resolved by code changes made to the upcoming release of our software NX 8.5.

1890267

Siemens PLM believes that the problem you reported where NX8 Modeling divide face requires a tighter tolerance than NX 7.5, will be resolved by code changes made to the upcoming release of our software NX 8.5. This issue has been verified as fixed in NX 8.5. However in NX 8 onwards, we do not allow modifications of the body through the Divide Face operation, which will result in a failure of the standard body check (if it passed earlier before the Divide Face operation). To make the Divide Face operation successful, without standard body check failures, we need to change the tolerance from .0254 to .00254.

1890397

CAM Express greyed out for Assemblies.

1890541

Siemens PLM believes that the problem you reported where JT file does not create from one assembly will be resolved by code changes made to the upcoming release of our software NX 8.5.

1890592

Siemens PLM believes that the problem you reported where post-processing plots of 'minimum' and 'maximum' von mises stress for thin shell elements can be wrong will be resolved by code changes made to the upcoming release of our software NX 8.5.

1890784

Siemens PLM believes that the problem you reported where Hole Tables are not created using Window Selection, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1890794

Siemens PLM believes that the problem you reported where following the use of the pull-down menu command 'edit, show and hide, hide' to hide the display of 'edge density' entities in an assembly fem, the simulation navigator incorrectly shows these items as still being visible (the 'tick box' remains 'ticked' and not greyed out), will be resolved by code changes made to the upcoming release of our software NX 8.5.

1890840

Siemens PLM believes that the problem you reported where Simulating CSE machine terminates with Errors will be resolved by code changes made to the upcoming release of our software NX 8.5. The user is responsible for naming the channel in the MCF so that it matches the channel_id_string. Given this mismatch between the "channel_id_string" (PARAM_MCT_CHANNEL_ID_INDEX) and the channel name in the MCF file, the ISV code never pushes the main line server into the stack IsvLineServerManager::m_lineServersStack. Later, when we query the stack to get the main line server (to get G-codeLines) the stack will be empty and we get an Internal Error because of a bad line server pointer. We added a check for the line so that the ISV dialog will not open for CSE simulation if the line server is empty. In NX 8.5 we also added a dialog to inform the user.

18908 Siemens PLM believes that the problem you reported where you were getting the error "There

Page 38: NX_Errors - 8.5

41 is an object which depends on itself" will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1890892

Siemens PLM believes that the problem you reported where Thread Point is missing after transform a WEDM Operation will be resolved by code changes made to the upcoming release of our software NX 8.5.

1890932

Siemens PLM believes that the problem you reported where Parser Error by using "ABST" on a Heidenhain-Controller with Cycle19 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1890961

Siemens PLM believes that the problem you reported where the NX Sheet Metal Contour Flange miter options were not effective will be resolved by code changes made to the upcoming release of our software NX 8.5. NOTE: The Contour Flange will have to be re-created in NX 8.5 in order to obtain the desired results.

1891002

Siemens PLM believes that the problem you reported where PLANE SPATIAL does not recognize Keyword FAUTO will be resolved by code changes made to the upcoming release of our software NX 8.5.

1891343

Siemens PLM believes that the problem you reported where PLANE SPATIAL does not recognize Keyword FAUTO will be resolved by code changes made to the upcoming release of our software NX 8.5.

1891345

Siemens PLM believes that the problem you reported where PLANE SPATIAL does not recognize Keyword TABLE ROT and/or COORD ROT will be resolved by code changes made to the upcoming release of our software NX 8.5.

1891398

Siemens PLM believes that the problem you reported where creating a new motion file for a specificy assembly file fails with "Memory Access Violation" in NX8 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1891479

Siemens PLM believes that the problem you reported where a new arrangement is not available in the Add Base View dialog, will be resolved by documentation changes made to the upcoming release of our software NX 8.5. The following description for Arrangements in the Base View options page of the Technical Documentation has been edited to read:

The Arrangement option appears in the Base View dialog box whenever an assembly arrangement is detected in the loaded assembly. To display an arrangement in a base view, select one from the Arrangement list. Any views subsequently projected from the base view display the same arrangement. If the Work Part contains any arrangements, then only those arrangements appear in the list. If there are no arrangements in the Work Part, then any arrangements residing at the next lower level assembly component are listed. However if there is more than one assembly component at the same level beneath the Work Part, then no arrangements in any of those parts ever appear in the list.

A similar description for Arrangements also appears on the View Creation Wizard page.

1891712

Siemens PLM believes that the problem you reported where Extended label in custom symbol has thick underline unless symbol is smashed will be resolved by code changes made to the upcoming release of our software NX 8.5.

1891744

Datum feature symbol arrow is placed incorrectly on perpendicular dimension.

Page 39: NX_Errors - 8.5

1891820

Siemens PLM believes that the problem you reported where auto-stitch didn't work correctly on a large model will be resolved by code changes made to the upcoming release of our software NX 8.5. With the full-scale model, using automatic edge-to-face stitching, with a search tolerance of 2 mm and a snap ends tolerance of 1 mm, the results are much improved although some free edges remain which can be manually stitched. Improvements were made to work with curved edges in edge-to-face stitching although the operation can take some time. The recommended approach to improve accuracy is to project the final mesh onto the CAD surfaces.

1891875

Siemens PLM believes that the problem you reported where the documentation did not supply enough information about creating an NX Routing Place Part callback with NXOpen .Net will be resolved by code changes made to the upcoming release of our software NX 8.5. This information has been added as a caveat in the Release Notes for NX 8.5.

1891939

Siemens PLM believes that the problem you reported where automatic edge-face stitching was resulting in lost faces will be resolved by code changes made to the upcoming release of our software NX 8.5.

1891968

Siemens PLM believes that the problem you reported where groups associated with a piece part fem that has been instanced into a sub-assembly afem cannot be used when post-processing the analysis results will be resolved by code changes made to the upcoming release of our software NX 8.5.

1892052

Siemens PLM believes that the problem you reported where the Cutting plane in post processing does not cut undeformed body display will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

1892101

Siemens PLM believes that the problem you reported where SectionData.GetRules fails with "No automation class found: PointFeatureRule" will be resolved by code changes made to the upcoming release of our software NX 8.5.

1892303

Siemens PLM believes that the problem you reported where Toolpath Verify 3D Dynamic gives wrong Result by using "Suppress Animation" will be resolved by code changes made to the upcoming release of our software NX 8.5.

1892308

Siemens PLM believes that the problem you reported where Internal Error after regeneration on wrong Geometry will be resolved by code changes made to the upcoming release of our software NX 8.0.3 and NX 8.5.

1892529

Siemens PLM believes that the problem you reported where a legacy On Curve point driven by an expression became un-associative in NX 8, will be resolved by code changes made to the upcoming release of our software NX 8.0.3. The new behavior will be that the original expression will be maintained and that a new expression will be created to drive the converted point. This new expression will reference the old expression and its formula will contain a multiplier that converts the parameter value from u-parameter to %-parameter. For example, if the original driving expression was M2, then the new expression will be something like pX = M2 * 100.0. The user can modify the original expression M2 by going into the Expression Editor (Tools -> Expression).

1892547

ExportJT gives Wrong Position for some components.

1892827

Siemens PLM believes that the problem you reported where some tool class descriptions are missing in the list inside tool_database.dat will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 40: NX_Errors - 8.5

1892881

Siemens PLM believes that the problem you reported where you were unable to select an offset spline to create a pattern in a sketch, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1893154

Siemens PLM believes that the problem you reported where "Draft/From Edges" in NX 8 produces wrong edges, will be resolved by code changes made to the upcoming release of our software NX 8.5. In order to see the results, the Draft feature has to be created new. Old draft features continue to update in old fashion only.

1893432

Siemens PLM believes that the problem you reported where Sketch Lines mirrored in an active Group did not get the Group Line Font, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1893496

Siemens PLM believes that the problem you reported where Gouge Check returns Error when Part/Blank Geometry is inherited will be resolved by code changes made to the upcoming release of our software NX 8.5.

1893767

Siemens PLM believes that the problem you reported where Newly Broken Links are not updated/accepted during feature playback will be resolved by code changes made to the upcoming release of our software NX 8.5.

1893864

Update not possible after breaking link.

1894196

Siemens PLM believes that the problem you reported where there seemed to be a difference in edge blend behavior in NX 8.0 as compared to NX 7.5 for what appeared to be identical parts is primarily due to a difference in part geometry, not a difference in software behavior. The two parts are very similar, but they are not identical. In the NX 8.0 part, there is a small edge that needs to be added to the selected edges to complete the chain of edges for creating the blend. If this edge is added to the edges to blend, then NX 8.0 will successfully create the blend. The Problem Report (PR) is marked as fixed in NX 8.5 because there will appear in that version more robust selection intent methods that will reduce the types of selection problems as are seen in this part. But even in NX 8.0 it is recommended that the user select the "Rib Top Face Edges" selection intent rule and select "Trim and Extend(63)" from the Part Navigator.

1894197

Siemens PLM believes that the problem you reported where the Sew feature Tolerance is not working for an Offset Face as expected will be resolved by code changes made to the upcoming release of our software NX 8.5.

1894389

Siemens PLM believes that the problem you reported where Offset Face failed depending on the Target/Tool face selection for Sew, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1894515

Siemens PLM believes that the problem you reported where point to point connection fails when selecting coincident control points will be resolved by code changes made to the upcoming release of our software NX 8.5.

1894524

Siemens PLM believes that the problem you reported where chamfer corners remained visible when "Show Interior Feature Curves" of Flat Pattern was unchecked, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1894748

Siemens PLM believes that the problem you reported where a fem file will not load into NX when the associated sim file is open will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 41: NX_Errors - 8.5

1894970

Siemens PLM believes that the problem you reported where "Show Thickness by Color" does not return negative values in NX 8.0.1 as it did in NX 7.5.5 will be resolved by code changes made to the upcoming releases of our software NX 8.0.3 and NX 8.5.

1895012

Siemens PLM believes that the problem you reported where NX does not export the inertia defined in the uploaded model to an ABAQUS input file, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

1895106

Siemens PLM believes that the problem you reported where NX cannot copy and paste a mirror body which has a linked coordinate system as its parent will be resolved by code changes made to NX 8.5.

1895109

Siemens PLM believes that the problem you reported where it should not be possible to remove an item from a project while revising that item in NX Manager, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1895268

Control string referencing attribute from component changes after closing note.

1895463

Siemens PLM believes that the problem you reported where removing parameters from a body with a UDF created a feature group, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1895933

Siemens PLM believes that the problem you reported where the NXOpen > ProeImporter > Commit method failed with an internal error when used in batch mode, will be resolved by code changes made to the upcoming releases of our software NX 8.0.3 and NX 8.5. The fix has also been submitted to the next available maintenance pack for NX 7.5.5.

1895975

Siemens PLM believes that the problem you reported where the NXOpen ProEimporter documentation incorrectly refers to CreateIgesImporter will be resolved by code changes made to the upcoming release of our software NX 8.5.

1895980

Siemens PLM believes that the problem you reported where NX Manager is limited to showing no more than 21 Advanced Queries will be resolved by code changes made to NX 8.5.

1896065

Siemens PLM believes that the problem you reported where Sentinel driver distributed with NX 8 not will install on Windows 7 system unless UAC is disabled will be resolved by releasing a newer software package for the Sentinel devices in the upcoming release of our software NX 8.5. As a work-around you can download this new package from http://www.safenet-inc.com/support_and_downloads/Download_Drivers/Sentinel_Drivers/.

1896095

Siemens PLM believes that the problem you reported where the Thread Pitch for Inch Helical Coil NC #8-32 was incorrect in the file Nx502_Threaded_Hole_Standard.xml, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1896172

Siemens PLM believes that the problem you reported where Boundary Selection does not work when linked Face is involved will be resolved by code changes made to the upcoming release of our software NX 8.5.

1896316

Siemens PLM believes that the problem you reported where the global deformation is showing an incorrect result in NX 8.0.1 and beyond will be resolved by code changes made to NX 8.5.

Page 42: NX_Errors - 8.5

1896487

Siemens PLM believes that the problem you reported with a specific .fem model where the 'mid-surface thickness' value is incorrectly evaluated as zero at some nodes will be resolved by code changes made to the upcoming release of our software NX 8.5.

1896500

Siemens PLM believes that the problem you reported where the 'Measure Projected Distance' documentation was not complete will be resolved by code changes made to the upcoming release of our software NX 8.5.

1896650

Siemens PLM believes that the problem you reported where Move Objects, using Select All, behaved differently when there was a group created and using the MODEL Reference Set, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1896681

Siemens PLM believes that the problem you reported where the NXOpen.Drawings > DrawingSheet > GetDraftingViews threw an invalid cast exception if there was a View Break on the drawing, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1896747

Siemens PLM believes that the problem you reported where the 'Subract' operation creates self-intersections in NX 7.5.5.4, but not in NX 8.0.2.2 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1896814

Siemens PLM believes that the problem you reported with a specific .fem model where the 'mid-surface thickness' was a single uniform value when it should have varied will be resolved by code changes made to the upcoming release of our software NX 8.5.

1896816

Siemens PLM believes that the problem you reported where you find inexactness of angle calculation during kinematic motion will be resolved by code changes made to the upcoming release of our software in NX Motion Simulation Version 8.5.

1896849

Siemens PLM believes that the problem you reported where manual text is deleted in parts list after addition of components and update of parts list will be resolved by code changes made to the upcoming release of our software NX 8.5.

1897303

Siemens PLM believes that the problem you reported where customizable item for the "channel" option is not available for blade operations will be resolved by code changes made to the upcoming release of our software NX 8.5.

1897432

Fillet Weld Crosshatch disappears.

1897446

Siemens PLM believes that the problem you reported where the turning spun outline generates with many small lines in the given part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1897453

Siemens PLM believes that the problem you reported where adding imported Ideas symbols corrupted the NX session, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1897469

Siemens PLM believes that the problem you reported where the tool gouges the part geometry in a Cavity Milling operation with a Profile cut pattern and using an endmill with a "Tip Angle", will be resolved by code changes made to the upcoming release of our software NX 8.5.

1897522

Siemens PLM believes that the problem you reported where an MP version could be reported when it did not exist will be resolved by code changes made to the upcoming release of our

Page 43: NX_Errors - 8.5

software NX 8.5.

1897755

Siemens PLM believes that the problem you reported where the Teamcenter folder structure had 2 folders with the same name and the content of these folders was not the same in NX, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1897790

Siemens PLM believes that the problem you reported where during playback, draft in NX 8.0.1.5 is different compared to NX 7.5.3.3 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1897791

Sketch Inconsistent.

1897856

Siemens PLM believes that the problem you reported where an expression's value did not appear left justified in the input field, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1898015

User Exit ufrcp not called while adding base view from part as of NX.6 PR 1805894.

1898035

Siemens PLM believes that the problem you reported where 1D spider does not update when a point is modified in modeling will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

1898055

Siemens PLM believes that the problem you reported where NX returns a memory access violation error when editing or generating a teachmode operation will be resolved by code changes made to the upcoming release of our software NX 8.5.

1898056

Siemens PLM believes that the problem you reported where Internal error creating a part family member will be resolved by code changes made to the upcoming release of our software NX 8.5.

1898140

Siemens PLM believes that the problem you reported where Wrong Spinning Geometry inside Tool-Assembly returns wrong IPW during Simulation will be resolved by code changes made to the upcoming release of our software NX 8.5.

1898474

Global Deformation records NXOpen.Die.SpringbackCompensationBuilder class.

1898492

Siemens PLM believes that the problem you reported where UF_DISP_batch_shade fails with IBL and user specified background will be resolved by code changes made to the upcoming release of our software NX 8.5.

1898633

Too many iterations in drawing update.

1898698

Siemens PLM believes that the problem you reported where Auto Group by Material doesn't work for Duct element will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

1899078

Siemens PLM believes that the problem you reported where NXOpen.SketchInPlaceBuilder.MakeOriginAssociative returns wrong values will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 44: NX_Errors - 8.5

1899098

Siemens PLM believes that the problem you reported where the UFWrapper method UFUi.CreateFilebox() omits wildcard characters while it works fine with Open C will be resolved by code changes made to the upcoming release of our software NX 8.5.

1899219

Siemens PLM believes that the problem you reported where a difference was reported between NX 8 and older versions of NX when opening an assembly file, if expressions in that file pointed to a spreadsheet on the network that could not be found, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1899232

Siemens PLM believes that the problem you reported where deleting a rigid element (created using the '1d connection' command), using the 'element operations, element delete' command results in the deletion of the mesh item and the associated collector if the deleted element is the only mesh item within that collector, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1899262

Siemens PLM believes that the problem you reported where removing the parameters from a WAVE linked body, and selecting the threads of that linked body, caused the threads and the body to be deleted. will be resolved by code changes made to the upcoming release of our software NX 8.5.

1899325

Siemens PLM believes that the problem you reported where UF_CAMBND_append_bnd_from_curve fails with single face in WEDM operation will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1899395

Siemens PLM believes that the problem you reported where Saving Excel Spreadsheet from Navigator uses incorrect filename will be resolved by code changes made to the upcoming release of our software NX 8.0.3 and NX 8.5.

1899485

Siemens PLM believes that the problem you reported where you may get the error "Failed to create boundary" in a 4-Axis Wire EDM operation (depending on the direction in which you select two faces on the supplied part), will be resolved by code changes made to the upcoming release of our software NX 8.5.

1899759

Siemens PLM believes that the problem you reported where a customer default was missing for Arc Weld Publishing will be resolved by code changes made to the upcoming release of our software NX 8.5.

1899806

Siemens PLM believes that the problem you reported where a journal created to generate 'envelope' results within nx post-processing (results manipulation) fails to replay correctly if the journal was recorded with the results already loaded, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1899891

Siemens PLM believes that the problem you reported where the Thread Depth of a Threaded NPT Hole could not be modified, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1899925

Siemens PLM believes that the problem you reported where a STEP file does not open nor import to NX 7.5 / NX 8 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1899977

Siemens PLM believes that the problem you reported where UF_CAMBND_append_bnd_from_curve fails to set material side in a EDM operation will be resolved by code changes made to the upcoming release of our software in NX 8.5.

Page 45: NX_Errors - 8.5

1900040

Siemens PLM believes that the problem you reported that some names of objectes in Step-File are not in NX after import will be resolved by code changes made to the upcoming release of our software is fixed and submitted in NX 8.5 and NX 7.5.5 MP as well.

1900064

Siemens PLM believes that the problem you reported where Sketch line(s) does not show during drag when cursor is held still will be resolved by code changes made to the upcoming release of our software NX 8.5.

1900197

Siemens PLM believes that the problem you reported where an Object Attribute Notes was incorrect, will be resolved by code changes made to the upcoming release of our software NX 8.5 Information about the object that owns the attribute referenced is now output to the information window when using the Object Information command in release NX 8.5. For example, if a note contains a reference to part attribute ATT1 then the information window will display the following data: Text String <WRef1*0@ATT1> Text References Ref1*0 Attribute Title ATT1 Attribute Owner Part Attribute Value First value In another example, if a note contains a reference to attribute ATT2 on a component named MYCOMP then the information window will display the following data: Text String <WRef2*0@ATT2> Text References Ref2*0 Attribute Title ATT2 Attribute Owner Component : MYCOMP Attribute Value Second value.

1900324

Ex -Feature update different when using UGII_SMP_ENABLE=1 is set versus not set.

1900463

Siemens PLM believes that the problem you reported where using the 'paver' meshing method results in a poor quality mesh will be resolved by code changes made to the upcoming release of our software NX 8.5.

1900515

Siemens PLM believes that the problem you reported where a Reference Set could not be changed by a PTS visual rule with renamed components, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1900661

Siemens PLM believes that the problem you reported where postprocessing with a B Head loaded on an ISV machine fails to output code will be resolved by code changes made to the upcoming release of our software NX 8.5.

1900704

Siemens PLM believes that the problem you reported where in TPB simulation, Drilling operations using the RTRCTO option 'Auto' would show incorrect simulation, will be resolved by code changes made to the upcoming release of our software NX 7.5.

1900709

Siemens PLM believes that the problem you reported where Extrude fail to update after editing sketch dimension will be resolved by code changes made to the upcoming release of our software NX 8.5.

1900773

Siemens PLM believes that the problem you reported where the Geometry linker function will not select multiple Composite curves in Exploded View,will be resolved by code changes made to the upcoming release of our software NX 8.5.

1900790

Siemens PLM believes that the problem you reported where no Java UFWrapper exists for UF_CAMBND_ask_boundary_app_data() will be resolved by code changes made to the upcoming release of our software NX 8.5.

1900906

Siemens PLM believes that the problem you reported, where there are only one pin and one bolt will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 46: NX_Errors - 8.5

1901109

Siemens PLM believes that the problem you reported where an Internal Error occurred when deleting a User Defined Object (UDO) which was linked to a component using the link type 2, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1901266

Siemens PLM believes that the problem you reported where NX creates a non-compliant AP214 step file will be resolved by code changes made to the upcoming release of our software NX 8.0.2MP2 and NX 8.5.

1901308

Siemens PLM believes that the problem you reported where Chamfer created on 64bit NX is different than the same chamfer created on 32bit will be resolved by code changes made to the upcoming release of our software NX 8.5.

1901313

Siemens PLM believes that the problem you reported where NX 8.0 won't start, due to very large (2-4GB) Dialog Memory File will be resolved by code changes made to the upcoming release of our software NX 8.5.

1901404

Siemens PLM believes that the problem you reported where NXOpen.BasePart.FullPath returns the descriptive part name based on the assemblies preference rather than the full path name will be resolved by code changes made to the upcoming release of our software NX 8.5.

1901479

Siemens PLM believes that the problem you reported where a Bounding Cylinder 'Offset' value is ignored in 2D Dynamic but 3D Dynamic is ok will be resolved by code changes made to the upcoming release of our software in NX 8.5.

1901482

Siemens PLM believes that the problem you reported where Part Family requirements for Copying and Pasting operations between parts are not documented will be resolved by code changes made to the upcoming release of our software NX 8.5.

1901607

Siemens PLM believes that the problem you reported where "wrong selection tangent points to create dimension", will be resolved by code changes made to the upcoming release of our software NX 8.5.

1901629

Siemens PLM believes that the problem you reported where a part file failed to open raising an Internal Error, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1901760

Siemens PLM believes that the problem you reported where the function Edit With Rollback improperly launches an update on another part will be resolved by code changes made to the upcoming release of our software NX 8.5. A work-around in NX 8 and earlier would be to edit the feature or parameter when no other NX part files are loaded in the assembly.

1901810

Siemens PLM believes that the problem you reported where Parser Error bei CSE Simulation Messzyklus TCH PROBE 403 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1901844

Siemens PLM believes that the problem you reported where user is unable to edit Legacy Surface Finish Symbols will be resolved by code changes made to the upcoming release of our software NX 8.5 phase 21.

1901883

Changing expression value improperly launches update on another part.

1901965

Siemens PLM believes that the problem you reported where you see poor accuracy of acceleration calculated by RecurDyn solver will be resolved by code changes made to the upcoming release of our software NX Motion Simulation Version 8.5.

Page 47: NX_Errors - 8.5

1902003

Siemens PLM believes that the problem you reported where GRIP BLANK/ALL fails with an Internal Error and "No entries on stack to pop integer from" will be resolved by code changes made to the upcoming release of our software NX 8.5.

1902091

Siemens PLM believes that the problem you reported where CSE Simulation for Heidenhain-Code get a Parser-Error during reading QS-Parameter will be resolved by code changes made to the upcoming release of our software NX 8.5.

1902094

Siemens PLM believes that the problem you reported where CSE Simulation with Heidenhain-Code : Parser-Error during TCH PROBE 1.0 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1902181

Siemens PLM believes that the problem you reported where SIM_move_circular_zcs did not function properly when running machine code simulation will be resolved by code changes made to the upcoming release of our software NX 8.5.

1902195

Siemens PLM believes that the problem you reported where a wave link at timestamp from read only part impossible to open up to date, will be resolved by code changes made to the upcoming release of our software NX 8.5. The modification issue: If a part goes through an update that not necessarily has any net geometry change, it will be marked as modified regardless it is done by user explicitly or by the system internally. In this case, when user edit the linked feature's at time stamp feature, we have to internally do some operation on the source part so the linked body can be correctly created after the block. So the source part is marked as modified as designed due to this internal update. If you still think this need to be improved, please do a request for enhancement. Out of date issue: Before NX 8.5, we mark the linked out of date as long the linked part is not in sync with the source part (source part is not saved when the linked is udated). That is as design. However in NX 8.5, we did a project so the linked body feature's out of date status can be more accurate based on the real net geometry change. But this functionality will only take effect if the parts are newly created, or user plays back the source and the linked parts and save them (cannot be read only). Then they can make the source read only and edit the linked body but only save the linked part. Next time they load the parts, the linked would be up to date.

1902217

Siemens PLM believes that the problem you reported where the performance of applying surface finish marks was slow will be resolved by code changes made to NX 8.5.

1902248

Siemens PLM believes that the problem you reported where Analyze Formability returned wrong shapes, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1902289

Siemens PLM believes that the problem you reported where the "Draw Direction" selection is marked as required in case of entire unform and advanced unform will be resolved by code changes made to the upcoming release of our software NX 8.5.

1902327

Siemens PLM believes that the problem you reported where User exit in "Weld Point" incomplete will be resolved by code changes made to the upcoming release of our software. The problem where the Weld_WeldPointExitBuilder is not called on edit for Mirror or Translate has been fixed in NX 8.5.

1902449

Siemens PLM believes that the problem you reported where using the One-step-Formability, the feature side cannot be specified when it needs to be reversed will be resolved by code changes made to the upcoming release of our software NX 8.5.

1902495

Siemens PLM believes that the problem you reported where a read only part is modified will be resolved by code changes made to the upcoming release of our software NX 8.5 and NX

Page 48: NX_Errors - 8.5

8.0.3.

1902632

Siemens PLM believes that the problem you reported where editing an SB Jog feature and selecting Reverse Side incorrectly flipped the Base Flange (not the jog), will be resolved by code changes made to the upcoming release of our software NX 8.5.

1902654

Siemens PLM believes that the problem you reported where the Open C API function UF_MODL_create_relative_dplane failed when attempting to create a Datum Plane with the two constraints "Through face axis" and "Angle to plane", will be resolved by code changes made to the upcoming release of our software NX 8.5.

1902752

Siemens PLM believes that the problem you reported no ability to store Exploded Views in Master Part will be resolved by code changes made to the upcoming release of our software NX 8.0.3 and NX 8.5.0.

1903049

Siemens PLM believes that the problem you reported where update of assembly constraints is incorrect after editing a deformable part, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1903054

Siemens PLM believes that the problem you reported where selecting coincident points in the Point to Point selection method of the One-Step Formability, the second point was not selectable, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1903129

Siemens PLM believes that the problem you reported where stitching midsurfaces on supplied model resulted in a hang of NX will be resolved by code changes made to the upcoming release of our software NX 8.5.

1903468

Siemens PLM believes that the problem you reported where the Action pulldown menu of the NXManager "Save Part File As" UI had a fixed and limited length and truncated the strings, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1903586

Siemens PLM believes that the problem you reported where Start NX/CAM in TC crashed when Machine CSE is not recognized inside TC (using "Use Postprocessors and ISV Drivers from Teamcenter" ) will be resolved by code changes made to the upcoming release of our software NX 8.5

1903716

Siemens PLM believes that the problem you reported where changing feedrates needs to update cavity milling operations will be resolved by code changes made to the upcoming release of our software NX 8.5.

1903732

Siemens PLM believes that the problem you reported where calling NXOpen.Preferences.LoadDraftingStandardBuilder.Name throws a SEHException will be resolved by code changes made to the upcoming release of our software NX 8.5.The fix will also be submitted to the next available MPs for NX 8.0.2 and NX 8.0.3.

1903782

Siemens PLM believes that the problem you reported where the customer defaults setting for the Exporter Unit System was not honored for the ABAQUS solver language will be resolved by code changes made to the upcoming release of our software NX 8.5.

1903833

NX/manager import: wrong characters in item name.

1903915

PMI Appended Relationships are not propagated to masterpart.

Page 49: NX_Errors - 8.5

1904019

Siemens PLM believes that the problem you reported where editing a Surface Finish Symbol in NX 8 unexpectedly displayed a (null) value in the dialog, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1904168

Siemens PLM believes that the problem you reported where collisions were not reported by ISV when the chuck jaw is not on the Work Plane will be resolved by code changes made to the upcoming release of our software NX 8.5.

1904201

Siemens PLM believes that the problem you reported where heat flux results arrow plots wrong if referencing a material coordinate system will be resolved by code changes made to the upcoming release of our software NX 8.5.

1904344

Siemens PLM believes that the problem you reported where Feature Identification functionality and Column creation applied to Limits and Fits in FBM will be resolved by code changes made to the upcoming release of our software NX 8.5.

1904397

Siemens PLM believes that the problem you reported where CSE Simulation stalls when using binary Files in Subprog-Folder will be resolved by code changes made to the upcoming release of our software NX 8.5.

1904440

Siemens PLM believes that the problem you reported where creating a Detail View from a partial loaded Reference Component throws an internal error will be resolved by code changes made to the upcoming release of our software NX 8.5.

1904450

Siemens PLM believes that the problem you reported where selecting several items (say, several Forces or several constraints or several MMC or several 0d/1d/2d/3d meshes) using <Shift> key or <Ctrl> key in the Simulation Navigator in the fem and sim file and THEN selecting the red check mark to have them displayed or hidden takes this setting (red check mark ON or OFF) for all the selected entities but, this does not happen in Post-processing Navigator when several meshes (under 'Post view') are selected and the red check mark is turned ON or OFF will be resolved by code changes made to the upcoming release of our software NX 8.5.

1904508

Siemens PLM believes that the problem you reported where the termination of the Stress Wizard leaves CAE objects in part will be resolved by code changes made to the upcoming release of our software. The problem where CAE entities may still be visible after canceling out of Stress Wizard is fixed in release NX.8.5.

1904510

Siemens PLM believes that the problem you reported where the Stress Wizard remains after the calculation in the background will be resolved by code changes made to the upcoming release of our software NX 8.5.

1904511

Siemens PLM believes that the problem you reported where Ingoring setting in the StressWizard Post animation will be resolved by code changes made to the upcoming release of our software. The problem in the Stress and Vibration Wizards where the post-processing template did not support complete animation settings override has been fixed in NX 8.5, phase 21, build 262. The post-processing templates have been updated to the new NX 8.5 format. Old style templates are still supported if the customer has developed their own overrides.

1904532

Siemens PLM believes that the problem you reported where the reference "APPUID-OBJ" was missing when an altrep was created in TC, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1904550

Siemens PLM believes that the problem you reported where CAM: Inherited Pocket-ID is no longer a "String" will be resolved by code changes made to the upcoming release of our

Page 50: NX_Errors - 8.5

software NX 7.5.5 MP4, NX 8.0.3.4 , NX 8.5.2.1.

1904577

Value with no "User Entry Name" inside a query, displays a selection box in NX.

1904581

Siemens PLM believes that the problem you reported where a Seam Weld disappeared when a Breakout Section was created, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1904642

Siemens PLM believes that the problem you reported where CSYS created from BlockStyler UI is never assocative will be resolved by code changes made to the upcoming release of our software NX 8.5 with adding a new property named SmartUpdateOption to the Specify Point Block.

1904802

Siemens PLM believes that the problem you reported where the message, "Unknown error" occurred when loading SOL 601 results into the post processor will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5 Development indicated the following: From the syslog it looks like the memory allocation is not getting enough blocks as requested - this issue is addressed in NX 8.5 by allowing a special switch to allocate a larger portion of memory.

1904825

Siemens PLM believes that the problem you reported where you were not able to use Insert -> Weld Assistant -> Bead on mirrored bodies will be resolved by code changes made to the upcoming release of our software NX 8.5.

1904892

Probing Dir aligned with Z in NX 7.5.2 but flips to face normal in NX 8.0.2.2.

1904989

Siemens PLM believes that the problem you reported where NXOpen.Part.Annotations.WeldStandard shows an "Internal Error" will be resolved by code changes made to the upcoming release of our software NX 8.5. Weld functionality has been enhanced to have multiple weld symbols in a part file in NX 8.5. Hence user will have freedom to set any weld standard (from available options) interactively and through open API.

1905086

Siemens PLM believes that the problem you reported where German Translation for Probing Dialog is not correct will be resolved by code changes made to the upcoming release of our software NX 8.5.

1905117

Siemens PLM believes that the problem you reported where entering a numeric value with a comma instead of decimal point while editing beam cross sections will be resolved by code changes made to the upcoming release of our software NX 8.5.

1905160

Siemens PLM believes that the problem you reported where duplicate coordinate systems within the bulk data are seen to import incorrectly will be resolved by code changes made to the upcoming release of our software NX 8.5.

1905224

Siemens PLM believes that the problem you reported where you have problems hiding the element edges will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

1905263

Expressions with reference to missing spreadsheet are slow to update on load.

Page 51: NX_Errors - 8.5

1905329

Siemens PLM believes that the problem you reported where the provided part updates in NX 6 but fails to update in NX 8 with Replace Face (297) reporting "No face selected for operation", will be resolved by code changes made to the upcoming release of our software NX 8.5.

1905382

Siemens PLM believes that the problem you reported where an Internal Error was received when copying / pasting a drawing containing a title block will be resolved by code changes made to the upcoming release of our software NX 8.5. The template part file is corrupted and caused the issue for the rest of the PR workflow. The root cause is fixed, however the template part file was created before fixing the main issue. So the problem exists in the template file. To repair the corrupted template part, open the template part file in NX, run the command 'File -> Utilities -> Part Clean up'. Make sure the "Clean Drafting Objects" toggle is On and hit the Ok button. Once this is done, save the template part file. Now it is ready to use as per the PR workflow.

1905461

STOPPING Solid Mesh required a double STOP action.

1905467

Siemens PLM believes that the problem you reported where part of sketch flip and make extrude section invalid in NX 8.0.2 on a part created in NX 6 will be resolved by code changes made to the upcoming release of our software NX 8.5. As earlier stated there is a work-around. - If playback all ready have been run in NX 8.0.2, Sketch(43) can be modified back to its original (symetric) shape using normal editing procedure. - Or, in NX 6.0.5 or in NX 8.0.2, having the part file in its original state the sketch flip can be prevented by the following steps:

1. Edit with Rollback on Extrude(44)2. De-select section string3. Change selection intent from Feature Curves to Connected Curves4. Select the Sketch(43) curves to be used as extrude section

1905639

Siemens PLM believes that the problem you reported where a Cavity Milling operation's status goes to "Regenerate" if a UDE is added to its reference tool will be resolved by code changes made to the upcoming release of our software NX 8.5.

1905866

Siemens PLM believes that the problem you reported where RecurDyn solver gives incorrect results will be resolved by code changes made to the upcoming release of our software NX Motion Simulation Version 8.5.

Note that the first reported problem is due to incorrect usage. please change the first value of drv 02_Lenkung, revolute in excel file to zero.

1905922

Siemens PLM believes that the problem you reported where JT contain PMI from Solid Edge cannot be opened in NX will be resolved by code changes made to the upcoming release of our software NX 8.5.

1905970

Siemens PLM believes that the problem you reported where Ordinate Dimensions flipped having using the 2D Exchange translator to export drawings to a new part, will be resolved by code changes made to the upcoming release of our software NX 8.5, NX 7.5.5 MP3 and N 8.0.3.

1905993

Siemens PLM believes that the problem you reported where the NXOpen for C++ method SheetmetalManager::GetInnerBendFaces() fails with "vector<T> too long" will be resolved by code changes made to the upcoming release of our software NX 8.5 and NX 8.0.3.

19061 Siemens PLM believes that the problem you reported where a Sketch angle at 181 degrees

Page 52: NX_Errors - 8.5

97 went to the 1 degree position, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1906236

Siemens PLM believes that the problem you reported where a Block UI Styler Drawing Area block, which is part of a seed dialog used with the Set List block, did not display the new picture when the Image property was changed using the NXOpen.BlockStyler > PropertyList > SetFile method, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1906258

Siemens PLM believes that the problem you reported where the Feature Types returned from mqc_report_feature_type don't match the Part Navigator "Feature Type" column will be resolved by code changes made to the upcoming release of our software NX 8.5.

1906366

Siemens PLM believes that the problem you reported where it is not possible to add the "Ignore Min. Boring Dia." item with Customize Dialog will be resolved by code changes made to the upcoming release of our software NX 8.5.

1906385

Siemens PLM believes that the problem you reported where the free body diagram interface selection on a section face did not work correctly will be resolved by code changes made to the upcoming release of our software NX 8.5.

1906643

Siemens PLM believes that the problem you reported where the part did not open in NX 8.0.2 will be resolved by code changes made to the upcoming release of our software NX 8.5 and NX 9. Please contact the coordinator if you would like the repaired NX 8.0.2 part.

1906735

Siemens PLM believes that the problem you reported where Folders display with a Part Icon in "Reuse Library -> Member Select ->List view" will be resolved by code changes made to the upcoming release of our software NX 8.5.

1906790

Siemens PLM believes that the problem you reported where the NX Open method Features.DatumCsys.GetEntities() returned all of the DatumCsys component entities except the CSYS will be resolved by code changes made to the upcoming release of our software NX 8.5.

1906793

Siemens PLM believes that the problem you reported where there is no symbol display of LBC when using RMB on item in graphic window will be resolved by code changes made to the upcoming release of our software NX 8.5.

1906794

Siemens PLM believes that the problem you reported where when changing the BC type after an item is already selected, results in the selection being lost will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

1906937

Stand-Alone Translators not compatible with DFS environment in Windows 7.

1906947

Saving an asssembly with deformable components throws error code 1770002.

1907083

UNC paths are not supported by IGES, STEP, DXF/DWG translators.

1907141

NX 8 unable to startup : Bad size (-2145386498) for allocation request.

19071 Siemens PLM believes that the problem you reported where opening the supplied STEP file

Page 53: NX_Errors - 8.5

68 failed reporting "Error number: 1", will be resolved by code changes made to the upcoming release of our software NX 8.5.

1907478

Siemens PLM believes that the problem you reported where "Edit Feature" throws an "Unknown Error" and SaveAs reports a "Part Corruption" will be resolved by code changes made to the upcoming release of our software NX 8.5.

1907535

Siemens PLM believes that the problem you reported where the Replace Component operation fails to maintain constraint associativity when a promotion subassembly is replaced with a clone of the same subassembly will be resolved by code changes made to the upcoming release of our software NX 8.5.

1907709

Siemens PLM believes that the problem you reported where Downgrade of hatch functionality in NX8 will be resolved by code changes made to the upcoming release of our software NX 8.5.

1907872

Siemens PLM believes that the problem you reported where results cannot be post-processed with respect to the material coordinate system will be resolved by code changes made to the upcoming release of our software NX 8.5.

1908013

The following circular update was detected if edit parameters.

1908042

Siemens PLM believes that the problem you reported where Adding a plain Reusable Component to an assembly modifies the component part will be resolved by code changes made to the upcoming release of our software NX 8.5.

1908258

Siemens PLM believes that the problem you reported where Global shaping by function edit fails, will be resolved by code changes made to the upcoming release of our software NX 8.5.

1908529

Siemens PLM believes that the problem you reported where an NX6 Planar Mill operation generated in NX 7.5 does not output the specified "Linear - Relative to Cut" engage move will be resolved by code changes made to the upcoming release of our software NX 8.5.

1908549

Siemens PLM believes that the problem you reported where Bridge UI needs a "nx_freeform_2" license but the BridgeSurfaceBuilder API requires a "studio_free_form" license will be resolved by code changes made to the upcoming release of our software NX 8.5 and NX 8.0.3 MP1.

1908550

Wrong translation in German user interface.

1908584

Siemens PLM believes that the problem you reported where it seemed that the punch features in the sheet metal part caused poor performance during the Flat Pattern command will be resolved by code changes made to the upcoming release of our software NX 8.5. The user should create a new Flat Pattern in NX 8.5 to experience the performance benefit.

1908585

Siemens PLM believes that the problem you reported where Trace Lines failed to update with changes in geometry upon which they are based will be resolved by code changes made to NX 8.5.

1908948

Siemens PLM believes that the problem you reported where the "Set Machining Data" function was using incorrect database records to perform its data interpolation will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 54: NX_Errors - 8.5

1909201

Wrong translated german menu file when closing a read only part.

1909343

Failure in exporting DXF.

1909476

Siemens PLM believes that the problem you reported where Unite Feature disappears after edit of Instance Geometry Feature will be resolved by code changes made to the upcoming release of our software NX 8.5.

1909493

Siemens PLM believes that the problem you reported where the program terminates itself when drafting opens will be resolved by code changes made to the upcoming release of our software NX 8.5.

1910009

Siemens PLM believes that the problem you reported where apply a saved drafting standard gives a memory access error will be resolved by code changes made to the upcoming release of our software NX 8.5 and NX 8.0.3MP1.

1910247

DrawingSheet::GetDraftingViews returns views with UF_view_break_slave_subtype.

1910467

Siemens PLM believes that the problem you reported where the last pass in a Rough Bore operation does not machine the full length of the bore will be resolved by code changes made to the upcoming release of our software NX 8.5.

1910889

Not possible to open DFS folder in native translator.

1911132

tsai-wu failure criteria in nx/nx documentation is wrong...

1911378

Siemens PLM believes that the problem you reported where a move object is not possible due to an internal error will be resolved by code changes made to the upcoming release of our software NX 8.5.

1911741

Siemens PLM believes that the problem you reported where the value for "Electrode Design -> Trim Body -> Bounding Box Clearance" is not saved by dialog memory will be resolved by code changes made to the upcoming release of our software NX 8.5.

2046577

Siemens PLM believes that the problem you reported where the Open C function UF_OBJ_set_partially_shaded() sometimes failed to redisplay a face as partially shaded will be resolved by code changes made to the upcoming release of our software NX 8.5.

2052676

Siemens PLM believes that the problem you reported where NX 3.0.1: Basic Curve / Fillet creates a noncontact fillet will be resolved by code changes made to the upcoming release of our software NX 8.5 For NX 8.5, the gap between created fillet arc and second curve (0.009288) is well within distance tolerance (0.0254).

2053175

Siemens PLM believes that the problem you reported where in a Cavity Mill operation with "Use Tool Holder' selected, the holder collides with the part geometry will be resolved by code changes made to the upcoming release of our software NX 8.5.

2055696

Siemens PLM believes that the problem you reported where Feature updates in NX 2, fails to update in NX3 and later will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 55: NX_Errors - 8.5

2060780

Siemens PLM believes that the problem you reported where the Clearance Browser was out of date after calling the Open C API function UF_CLEAR_do_clearance_analysis, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2061958

Siemens PLM believes that the problem you reported where when generating a Surface Contouring operation the error "Attempt to free already free memory in Storage Manager" is returned will be resolved by code changes made to the upcoming release of our software NX 8.5.

2063046

Siemens PLM believes that the problem you reported where in NX 3 in a Cavity Mill operation with Cut Area selected the tool does not machine across voids which are fully enclosed in the cut area as noted in the Documentation will be resolved by code changes made to the upcoming release of our software NX 8.5.

2063267

Siemens PLM believes that the problem you reported where a toolpath is broken into segment with tool that is much smaller than geometry will be resolved by code changes made to the upcoming release of our software NX 8.5.

2069703

Siemens PLM believes that the problem you reported where Cavity Mill will not generate a tool path if a Cut Area is specified will be resolved by code changes made to the upcoming release of our software NX 8.5.

2070673

Siemens PLM believes that the problem you reported where NX produces an incorrect toolpath will be resolved by code changes made to the upcoming release of our software in NX 8.5.

2073602

Siemens PLM believes that the problem you reported where there was no API for MCS display will be resolved by code changes made to the upcoming release of our software NX 8.5.

2073826

Siemens PLM believes that the problem you reported where the Plotting documentation did not explain job naming restrictions, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

2076919

Siemens PLM believes that the problem you reported where image data was not exported to HPGL will be resolved by code changes made to the upcoming release of our software NX 8.5.

2077683

Siemens PLM believes that the problem you reported where 'Cannot save a file according to the file name rule defined in the documentation' will be resolved by changes made to the upcoming release of our software NX 8.5.

2077730

Siemens PLM believes that the problem you reported where the plot layout could not be confirmed will be resolved by code changes made to the upcoming release of our software NX 8.5.

2079487

Siemens PLM believes that the problem you reported where the documentation for the History Palette was not appropriate will be resolved by code changes made to the upcoming release of our software NX 8.5. The modified content in Help under 'Home > Fundamentals > NX Interface > Palettes > System Palettes' topic now reads as: The History palette automatically updates or deletes the entries that are more than 31 days old based on the following condition. From all the entries that are more than 31 day old, if the number of entries are greater than 200 then NX removes 200 oldest entries on startup and retains the rest of the entries. Example: If the total number of files that are more than 31 days old is 350 then NX deletes the 200 oldest files on startup and retains the remaining 150 files. You can remove all the entries from the History palette; right-click in the palette background and select Clear History.

Page 56: NX_Errors - 8.5

2082381

Siemens PLM believes that the problem you reported where the Open C API function UF_DRAW_set_dmv_rotation_plane returned unregistered error codes and had insufficient documentation, will be resolved by changes made to the upcoming release of our software NX 8.5.

2087149

Siemens PLM believes that the problem you reported where 'Split By line' option of Split Shell command , in most cases, goes through the entire length of the element only even when completely different points were selected will be resolved by code changes made to the upcoming release of our software NX 8.5. We have added additional information to the Split Shell documentation to explain how Split by Line works. We have changed the wording that indicated the software split the element along the specified line to state the that the software uses the line to determine where and how to split the element, but that the element may not be exactly split along that location. We have added additional information about the software always creating a new node to divide the element's edge in the middle of the edge. Hopefully, these changes will make more clear what is happening with the Split by Line method. These changes will appear in the NX 8.5 help library. Thank you for bringing this issue to our attention.

2087354

Siemens PLM believes that the problem you reported where the direction arrow fails to appear using Edit Parameters, yet does work in Edit With Rollback will be resolved by code changes made to the upcoming release of our software NX 7.5 and later releases.

2088163

Siemens PLM believes that the problem you reported where the deviation between curve and surface was more than the set tolerance of 0.001, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2088680

Testing shows that the problem described in the PR text with modifying the position of the "arm" component in the test assembly and saving to Teamcenter no longer occurs in NX 8.5.

2089972

Siemens PLM believes that the problem you reported where the default sheet body color appears in the form of a solid body's color will be resolved by code changes made to the upcoming release of our software NX 8.5.

2090328

Siemens PLM believes that the problem you reported where: Even if preferences of 'Image Type' is changed,the changed content is not reflected." will be resolved by code changes made to the upcoming release of our software: The problem where the uncompressed file size was not reliable has been fixed in NX 8.5 by removing this information.

2092259

Siemens PLM believes that the problem you reported where the associated CSYS does not behave correctly when Editing with Rollback is resolved by code changes made to the release of our product NX 6.0.2 and NX.7.5.

2092274

Siemens PLM believes that the problem you reported where the Mirror feature was not working correctly for a Divide Face feature, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2094881

Siemens PLM believes that the problem you reported where Miter fails when using Cutout type "Normal To Source Face" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2098610

The problem where a structure with variant configuration and precise revision rules has been fixed in NX 8.5.

2102266

Siemens PLM believes that the problem you reported where the Post Navigator does not update after an event is created by PS wizard will be resolved by code changes made to the

Page 57: NX_Errors - 8.5

upcoming release of our software NX 8.5.

2102319

Siemens PLM believes that the problem you reported where execution of "Offset Face" generated an error, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2103179

Siemens PLM believes that the problem you reported where an Update Pending message is not removed after and update is performed will be resolved by code changes made to the upcoming release of our software NX version 8.5.

2104142

Siemens PLM believes that the problem you reported where a drawing had missing entities when plotting, will be resolved by code changes made to the upcoming release of our software NX 8.5. The solution for views that fails to plot correctly is to redefine the breakline/detail boundary is such a manner that no curves intersect with more than their two neighbor curves.

2104277

Siemens PLM believes that the problem you reported where a Zlevel Follow Core operation generates stepovers in the toolpath that far exceed the specified "Stepover" value will be resolved by code changes made to the upcoming release of our software NX 8.5.

2106566

Siemens PLM believes that the problem you reported where TIFF file export creates the same size file output regardless of the option type selected has been fixed in NX 8.5.

2106895

Siemens PLM believes that the problem you reported where Autoballoon Symbols could not be horizontally aligned as desired will be resolved by code changes made to the upcoming release of our software NX 8.5.

2107769

Siemens PLM believes that the problem you reported where the rendering style and background of a component part is not inherited to the parent assembly when selecting "Assemblies -> Components -> Create New Parent", will be resolved by changes to the documentation in the upcoming release of our software NX 8.5.

2108041

Siemens PLM believes that the problem you reported where the function Customer Default -> Analysis -> Modeled Part Validation -> Information provided results in Metric when the default units was set to Inches will be resolved by code changes made to the upcoming release of our software NX 8.

2108308

Siemens PLM believes that the problem you reported where an Interference Solid was not recreated using Assembly Clearance after deleting the original Interference Solid, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2108319

Siemens PLM believes that the problem you reported where the message "Modified Transform Action" is returned when opening an assembly will be resolved by code changes made to the upcoming release of our software NX 8.5 and TC8.3.3.

2108796

Siemens PLM believes that the problem you reported where After I import the CGM file,the annotation turns over when I create new it will be resolved by code changes made to the upcoming release of our software NX 8.5.

2109265

uc1653 returns wrong view name if OK picked in UF_UI_point_construct.

2109363

Siemens PLM believes that the problem you reported where Zlevel Profile is skipping levels and causing tool breakage will be resolved by code changes made to the upcoming release of our software in NX 8.5.

Page 58: NX_Errors - 8.5

2109617

Siemens PLM believes that the problem you reported where the show/hide state of "Display WCS" was incorrect having closed and reopened a component via the Assembly Navigator, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2109955

Siemens PLM believes that the problem you reported where an NX part file size increased after applying a Scale feature, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2109990

After following the steps you get "Analysis 100% completed" and no error, so the problem has been resolved and therefore will be closed.

2110270

Siemens PLM believes that the problem you reported where wrap fit method did not give correct result for certain multi line text in cells, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2111561

Siemens PLM believes that the problem you reported where transform results are different between similar models, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2113593

Siemens PLM believes that the problem you reported where in the 'Contour Flange' UI, the 'Start End' and 'finish End' Miter Cutout options are not holding the input values will be resolved by code changes made to the upcoming release of our software NX 7.5.

2113640

Siemens PLM believes that the problem you reported where a Jog relief is longer when sides reversed, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2113643

Siemens PLM believes that the problem you reported where setting the Jog Bend Relief to the "Round" option raised an alert, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2114058

Siemens PLM believes that the problem you reported where Unable to create circular array body will be resolved by code changes made to the upcoming release of our software NX 8.5 by using following conditions: You need to use new Patterning feature command available under Insert->Associative Copy -> Pattern feature which is available NX 8.5 onwards.

2114341

Siemens PLM believes that the problem you reported where saving a part having imported a drawing consisting of a Parts List with Balloons raised the error: "A deleted or invalid class id was used", will be resolved by code changes made to the upcoming release of our software NX 8.5.

2115221

Siemens PLM believes that the problem you reported where the user was getting linear moves in slot corners on some levels and circular on others will be resolved by code changes made to the upcoming release of our software in NX 8.5.

2115576

Siemens PLM believes that the problem you reported where spiral faces could not be meshed will be resolved by code changes made to the upcoming release of our software NX 8.5.

2115748

Siemens PLM believes that the problem you reported where a Slot was incorrectly created when using the Copy & Paste Feature functionality, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 59: NX_Errors - 8.5

2116321

Siemens PLM believes that the problem you reported where it was not possible to select the Tool edge (centerline of slot) for positioning having reattached a Dovetail Slot twice, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2117313

Siemens PLM believes that the problem you reported where the selected items did not match after a undo will be resolved by code changes made to the upcoming release of our software NX 8.5.

2118180

Siemens PLM believes that the problem you reported where an NX 5 Cavity Mill operation generated in NX6 produces Non Cutting Motion that was not in NX 5 along with the error "$$ Inconsistent arc axis" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2119475

Siemens PLM believes that the problem you reported where generating streamline operations might give a warning about "free hanging cross curves" that is not helpful to the user will be resolved by code changes made to the upcoming release of our software NX 8.5. The message and interaction have been revised to highlight the problem areas and thus make it easier for the user to identify these.

2119670

Siemens PLM believes that the problem you reported where the error "Datatype error" was returned when copying a feature from the Part Navigator with the Timestamp OFF will be resolved by code changes made to the upcoming release of our software NX 8.5.

2119696

"Part file saved." is not displayed when UGII_UGMGR_DISPLAY_READ_ONLY_WARNINGS_O

2121038

Siemens PLM believes that the problem you reported where the user could not use Move Face, using the direction vector of a Hole feature, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2122046

Miter does not work when setting Cutout type to "Normal To Source Face".

2122869

Siemens PLM believes that the problem you reported where Updating Curve of Arbitrary Region will not update PMI in Drafting will be resolved by code changes made to the upcoming release of our software NX 8.5.

2123345

The problem where Boolean face color transfer not working when keep target on is fixed in today's modeling group: Modeling_nx85.195

2124691

The problem where Face Mill gouges some area when machining sheet bodies has been resolved in NX8.0

2124718

Siemens PLM believes that the problem you reported where 'Select planar base face' reported during 'Convert to Sheetmetal'will be resolved by code changes made to the upcoming release of our software NX 8.5.

2124791

CSW Allow Menu Bar Customization is turned off with Customer Defaults.

2125159

Siemens PLM believes that the problem you reported where the TC Integration Customer Default Role is not being reflected in Preferences will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 60: NX_Errors - 8.5

2125165

Siemens PLM believes that the problem you reported where Sheet Metal HemFlanges failed update when the owning Sheet Metal part was imported into a new part file, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2125537

Siemens PLM believes that the problem you reported where you could not create an Inferred (PMI) Dimension because of an Invalid Parameter error will be resolved by code changes made to the upcoming release of our software NX 8.5.

2126567

Siemens PLM believes that the problem you reported where imported with Chinese Item name, it will be displayed as unreadable characters will be resolved by code changes made to the upcoming release of our software NX 8.5.

2127887

Siemens PLM believes that the problem you reported where the Check-Mate documentation for the functions ug_mqc_checkDrawingUpdated and mqc_checkDrawingUpdated incorrectly stated that the return value would be non-zero if an error occurred, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

2129072

Siemens PLM believes that the problem you reported where assigning Until Next as the Depth Limit did not work at some points when inserting a Hole, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2129099

Siemens PLM believes that the problem you reported where a PMI Dimension is placed at an unwanted location will be resolved by code changes made to the upcoming release of our software NX 8.5.

2129439

Siemens PLM believes that the problem you reported where a 4 axis Wire EDM tool path gouges the part geometry when using the "Non-Tilt Lead In" option will be resolved by code changes made to the upcoming release of our software NX 8.5.

2130987

Siemens PLM believes that the problem you reported where the ug_clone utility did not maintain Assembly Constraints, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2132274

Siemens PLM believes that the problem you reported where an invalid record number error occurs by a specific operation, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2132449

Siemens PLM believes that the problem you reported where a component is not displayed when it was loaded using the inter-part link browser, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2132974

Siemens PLM believes that the problem you reported where the "Last Modified" date in the File New dialog is incorrect when Time Zone is set will be resolved by code changes made to the upcoming release of our software NX 8.5.

2135082

Siemens PLM believes that the problem you reported where same parts are opened with different Reference Sets will be resolved by code changes made to the upcoming release of our software NX 8.5.

2135105

Siemens PLM believes that the problem you reported where Face Mill "Part Stock" causes cut area to be ignored will be resolved by code changes made to the upcoming release of our software NX 8.5.

2135242

Siemens PLM believes that the problem you reported where Wave->Copy Component As in managed mode would trigger an assertion error will be resolved by code changes made to the

Page 61: NX_Errors - 8.5

upcoming release of our software NX 8.5.0.

2135528

Siemens PLM believes that the problem you reported where Delete Face failed update with the provided part, will be resolved by code changes made to the upcoming release of our software NX 8.5. Please delete the old Delete Face feature and create a new one in NX 8.5 or later, it now succeeds to delete the target face.

2135728

Siemens PLM believes that the problem you reported where the Keep-in area of a Placement Group is not removed when "remove placement grouping" is set in the Entity filter while importing a ECAD file, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2135871

Siemens PLM believes that the problem you reported where the unsew is still linked with the original feature after removing its face from the unsew will be resolved by code changes made to the upcoming release of our software NX 8.5.

2136258

Siemens PLM believes that the problem you reported where calling the Open C function UF_ASSEM_initialize_sequencing() may result in the layout being changed will be resolved by code changes made to the upcoming release of our software NX 8.5.

2139901

Siemens PLM believes that the problem you reported where no interferences were found where expected, when performing clearance analysis in the top level assembly, will be resolved by code changes made to the upcoming release of our software NX 8.5 The problem here was that a single-child chain was not expected before finding first-level subassemblies. NX now checks for single-child chains of any length before identifying first-level subassemblies.

2140266

Siemens PLM believes that the problem you reported where Z-Level Profile with reference tool resulted in bad tool path will be resolved by code changes made to the upcoming release of our software NX 8.5. This was fixed in the project Efficient Rest Material Removal with Reference Tools. The customer can create a flowcut operation by using zlevel and flowcut patterns together with zlevel pattern cutting non-steep areas and crosscut pattern cutting steep areas to replace the original zlevel operation.

2140885

NX 7.5:Modeling/ The problem of the changing value of the distance in the Linear.

2141442

Siemens PLM believes that the problem you reported where inserting the provided UDF raised the message: "Unable to paste", will be resolved by code changes made to the upcoming release of our software NX 8.5.

2141816

PS24.1.148:NX7.5:Modeling, Shape changes by executing "Playback" _4y_MODEL_07.

2142117

Siemens PLM believes that the problem you reported where 2D Dynamic tool path verify is different from 3D Dynamic will be resolved by code changes made to the upcoming release of our software in NX 8.5.

2142302

[NXOpen]The return values of point constructor are difference between NX 5 and 6.

2143416

Siemens PLM believes that the problem you reported where a Face Milling retract move gouged the part will be resolved by code changes made to the upcoming release of our software in release NX 8.5.

Page 62: NX_Errors - 8.5

2143802

Siemens PLM believes that the problem you reported where a flange fails to update will be resolved by code changes made to the upcoming release of our software NX 8.5.

2144100

Siemens PLM believes that the problem you reported where a non-cutting move gouges the part will be resolved by code changes made to the upcoming release of our software NX 8.5.

2144197

CSW: "Could not create modeling curve in parasolid" creating an extrude.

2144710

Siemens PLM believes that the problem you reported where the documentation to explain the Part Navigator Delete Last Filter command needed more information will be resolved by code changes made to the upcoming release of our software NX 8.5.

2145250

Siemens PLM believes that the problem you reported where the Open C function UF_MODL_ask_face_props returns error code 671027 will be resolved by code changes made to the upcoming release of our software NX 8.5.

2145278

Siemens PLM believes that the problem you reported where Apply button is not effective when editing a WAVE link, will be resolved by code changes made to the upcoming release of our software NX 8.5. The Apply button is removed.

2146675

Siemens PLM believes that the problem you reported where the amplitude of break lines in the older style of broken views is incorrect will be resolved by code changes made to the upcoming release of our software NX 8.5. The fix cannot be applied to existing broken view boundaries, so it will be necessary to recreate the boundaries containing the incorrect break lines.

2147559

Siemens PLM believes that the problem you reported where the Control Point option was ineffective when selecting an Arc to insert a point, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2147702

Siemens PLM believes that the problem you reported where Heidenhain cycle definitions fail in ISV with the error "Parse error after reading '13 CYCL DEF 247 DATUM SETTING 14'" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2147746

Siemens PLM believes that the problem you reported where exporting customer defaults to a spreadsheet exported an obsolete NX Manager default; UGMGR_UseFMS, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2147857

Siemens PLM believes that the problem you reported where the Modify Part Preview option did not change the Modified Status of a part, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2148258

Siemens PLM believes that the problem you reported where user cannot choose the curves (action-object )in drafting imported view is fixed with new Move Object command, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2148747

Siemens PLM believes that the problem you reported where Replace Face(12) fails in Playback will be resolved by code changes made to the upcoming release of our software NX 8.5.

2149051

Siemens PLM believes that the problem you reported where After renaming a Reference Set, the new name isn't reflected in the ANT will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 63: NX_Errors - 8.5

2149080

Siemens PLM believes that the problem you reported where copying and pasting a drawing sheet that contains a crosshatch causing duplicate geometry to be created will be resolved by code changes made to NX 8.5.

2149261

Siemens PLM believes that the problem you reported where a Face Milling operation fails to cut the profile of a part but departs from the surface, will be resolved by code changes made to the upcoming release of our software NX 8.5. In NX 8.5, this face mill operation is automatically converted to a floor/wall milling operation, which - when generated - no longer exhibits the described problem.

2149375

Siemens PLM believes that the problem you reported where NX failed to save a mirror assembly and failed to save the parent assembly, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2149773

Siemens PLM believes that the problem you reported where the information on an excitation location ID is incomplete will be resolved by code changes made to the upcoming release of our software NX 8.5.

2149839

Siemens PLM believes that the problem you reported where there are incorrect vertical entry moves in cavity mill toolpath will be resolved by code changes made to the upcoming release of our software NX 8.5. In NX 8.5 Cavity Milling, when cut area is used, the blank definition is now used correctly to determine where open engage moves can be made outside of the blank.

2150014

Siemens PLM believes that the problem you reported where importing a step file with the SEW option turned on changes the face colors will be resolved by code changes made to the upcoming release of our software NX 8.5.

2150025

Siemens PLM believes that the problem you reported where STEP import does not process colors properly will be resolved by code changes made to the upcoming release of our software NX 8.5.

2150606

Siemens PLM believes that the problem you reported where inherited PMI dimensions became retained in Drafting immediately after draft view creation, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2150659

Siemens PLM believes that the problem you reported where importing IGES files with the SEW option turned on does not process face colors correctly will be resolved by code changes made to the upcoming release of our software NX 8.5.

2151445

Siemens PLM believes that the problem you reported where Wire EDM is getting duplicate UNLOAD/WIRE and LOAD/WIRE will be resolved by code changes made to the upcoming release of our software NX 8.5.

2151475

Siemens PLM believes that the problem you reported where the faces of a component disappear if partial shading is enabled for a component in an assembly and "Edit -> Object Display" is used to disable partial shading for some of the faces of the component, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2151852

About Hole Series.

2152657

Siemens PLM believes that the problem you reported where a UIStyler dialog hides after UF_CFI_spawn() is called will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 64: NX_Errors - 8.5

2153295

Siemens PLM believes that the problem you reported where editing a curve length did not result in the correct preview will be resolved by code changes made to the upcoming release of our software NX 8.5.

2153628

CPJ: Highlighted edge in Edge Blend will not un-highlight.

2153729

Siemens PLM believes that the problem you reported where an alert occurred when arranging a drawing view using the perpendicular to line option, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2153926

Siemens PLM believes that the problem you reported where users are unable to recreate a Thicken feature will be resolved by code changes made to the upcoming release of our software NX 8.5.

2154125

Siemens PLM believes that the problem you reported where line width was not maintained when using when copying a curve to another view using Project to View, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2154926

Siemens PLM believes that the problem you reported where a component with a fixed constraint moves in sequencing, will be resolved by code changes made to the upcoming release of our software NX 8.5 The Insert Motion tool now checks the selected components for a fix constraint. If a fix constraint is present in one of the components and the user has not yet been warned, a warning dialog is displayed notifying the user that a selected component has a fix constraint. The user is asked whether motion should be allowed. This behavior is mirroring the behavior of the Move tool.

2155449

Siemens PLM believes that the problem you reported where Animation of a Teach Mode operation shows strange motion when stepping through the subops will be resolved by code changes made to the upcoming release of our software in NX 8.5.

2155464

The problem where the 'Failed to interpret xml file correctly' is displayed after loading a Solid Edge assembly is fixed in release NX 8.5.

2155734

Siemens PLM believes that the problem you reported where an error occurs when a part has an assembly arrangement saved from the motion results, will be resolved by code changes made to the upcoming release of our software NX Motion Simulation, version 8.5.

2156358

Siemens PLM believes that the problem you reported where it is difficult to obtain the Origin of a ModelinView will be resolved by code changes made to the upcoming release of our software NX 8.5. A new method called AbsoluteOrigin has been added to make it easy to obtain this location.

2156610

Siemens PLM believes that the problem you reported where an error message was incorrectly translated in Japanese, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2156728

ps25.0.156 CPJ-VUP: UAF/UAD Failure(NX 7.5.2 ip4)-Offset Face is failed to update.

2156930

About "insert / design feature / hole".

Page 65: NX_Errors - 8.5

2157481

Siemens PLM believes that the problem you reported where the tool gouges the part geometry in a Face Milling Area operation when "Prevent Undercutting" is turned on will be resolved by code changes made to the upcoming release of our software NX 8.5.

2157598

Siemens PLM believes that the problem you reported where view boundary will be extended after inserting "Infinite Line", will be resolved by code changes made to the upcoming release of our software NX 8.5.

2158108

Siemens PLM believes that the problem you reported where the description for the Style option in the PMI 3D Centerline is wrong in Japanese, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2158216

Siemens PLM believes that the problem you reported where if you create a macro from the Manufacturing Application and you add a 'User Entry', you can no longer change modules or save and close your part will be resolved by code changes made to the upcoming release of our software NX 8.5.

2158502

The problem where the Concave Face results were not as expected has been converted to an Enhancement Request. Concave faces currently work in the draw direction. If the draw direction pierces the sheet more than once, then the result may not be correct, such as this case. We have submitted an Enhancement Request asking to add an option in the dialog so it will use the draw direction or the surface normal.

2158743

When I reattach the sketch to the endpoint, the sketch become over constraint.

2158761

ug_export records warning "UGMGR__is_hookup_spec got a long name.

2159742

Siemens PLM believes that the problem you reported where users could not select the planar face of a Product Outline part for a sketch plane, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2160169

Siemens PLM believes that the problem you reported where a ribbon builder's result is different by NX 3 and NX 5 will be resolved by code changes made to the upcoming release of our software NX 7.5.4 and NX 8.

2160913

Siemens PLM believes that the problem you reported where Flow Cut with Reference Tool is leaving some areas uncut will be resolved by code changes made to the upcoming release of our software in NX 8.5.

2160974

Siemens PLM believes that the problem you reported where dimension line is moved upon updating symbols in part with SBF, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2161048

The attribute does not copy using WAVE Mode.

2161199

Siemens PLM believes that the problem you reported where there were questions about Highlight Measurements in Feature Sets option, will be resolved by code changes made to the upcoming release of our software NX 8.5. The problem where the documentation for the Highlight Measurements in Feature Sets option was wrong is fixed in release NX 8.5. The modified content under Home > Fundamental > Customizing NX > Using Preferences > Measurement dialog box, now reads as: Displays the hidden measurements along with feature when you select a feature group or User Defined Features from the Part Navigator. By default,

Page 66: NX_Errors - 8.5

this check box is turned off.

2161360

Siemens PLM believes that the problem you reported where the Non-Cutting Move option "Direct Retract from Trim Point" is not working in NX 7.5.2 but did in NX 6.0.2.8 will be resolved by code changes made to the upcoming release of our software in NX 8.5.

2162129

Siemens PLM believes that the problem you reported where some parts cannot offer the "Original Features" preview window when pasting a copied feature into a part will be resolved by code changes made to NX 8.5.

2162275

Siemens PLM believes that the problem you reported where "Can't filter a feature with alerts", will be resolved by code changes made to the upcoming release of our software NX 8.5.

2162527

Reattaching On Path sketch creates an over-constrained condition.

2162670

Siemens PLM believes that the problem you reported where About the display color of the Datum CSYS will be resolved by code changes made to the upcoming release of our software NX 8.5.

2163012

Siemens PLM believes that the problem you reported where a Cut Body feature was in the MODEL Reference Set after a PMI Section Cut was performed, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2163483

In making a hole, the result of "End Chamfer"angle is incorrect.

2163885

Siemens PLM believes that the problem you reported where Move Component has worse performance when the Assembly Navigator is expanded will be resolved by code changes made to the upcoming release of our software NX 8.5. There will still be a smaller cost on exiting the dialog, but this is needed to re-figure the positioning statuses of the component nodes, which may change on dialog exit.

2163905

Siemens PLM believes that the problem you reported where it was not possible to use multi-byte strings with MessageDialog will be resolved by code changes made to the upcoming release of our software NX 8.5.

2163940

Siemens PLM believes that the problem you reported where About updata_structure.exe will be resolved by code changes made to the upcoming release of our software NX 8.

2164112

Siemens PLM believes that the problem you reported where a Cavity Mill rest mill operation gouges the part will be resolved by code changes made to the upcoming release of our software NX 8.5.

2164224

Siemens PLM believes that the problem you reported where when opening a part, the error "NX_Nav_.plmxml - Failed to load part" occurs, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2164355

Siemens PLM believes that the problem you reported where the Miter Direction of the Contour Flange is not correct will be resolved by code changes made to the upcoming release of our software NX 8.5.

2164854

Siemens PLM believes that the problem you reported where the migration report cannot be displayed will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 67: NX_Errors - 8.5

2164931

Siemens PLM believes that the problem you reported where rosette type strain gages wer returning plots in random events that did not correspond to other strain gages will be resolved by code changes made to the upcoming release of our software NX 8.5.

2165473

Siemens PLM believes that the problem you reported where There are some incorrect Japanese characters in NX 7.5.2 will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

2165623

Siemens PLM believes that the problem you reported where "Transform" was not properly translated to Japanese will be resolved by code changes made to the upcoming release of our software NX 8.5.

2166206

Siemens PLM believes that the problem you reported where inherited PMI associativity were not restored after a reference set swap, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2166404

Siemens PLM believes that the problem you reported where the Filter section of the tess*.config was removed in error when making a modification, will be resolved by changes made to the upcoming release of our software NX 8.5.

2166536

Siemens PLM believes that the problem you reported where the assembly product structure was not shown correctly in TCVis when JT was exported from Teamcenter will be resolved by code changes made to the upcoming release of our software NX 8.5.

2166612

Siemens PLM believes that the problem you reported where a b-surface could not be extracted from a face will be resolved by code changes made to the upcoming release of our software NX 8.5.

2166631

Siemens PLM believes that the problem you reported where a standard NX item revision query in Teamcenter did not account for sequences will be resolved by code changes made to the upcoming release of our software NX 8.5.

2167146

Datum CSYS.color changes in a sketch.

2167423

Siemens PLM believes that the problem you reported where the variable, SDI_WORK interfered with NX printing, will be resolved by code changes made to the upcoming release of our software, NX 8.5.

2167544

Siemens PLM believes that the problem you reported where orientation fails Sketch datum axes does not meet the user-specified constraints will be resolved by code changes made to the upcoming release of our software NX 8.5. Please note that since the change is under version control, the fix would be available  only to the Sketch features created in NX 8.5 or later. User has to recreate the sketch features in NX 8.5 to solve the issues mentioned in the PR.

2167591

Siemens PLM believes that the problem you reported where when doing ugmanager_clone using -n=${DB_PART_NO}, DB_PART_NO is not used, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2167603

Siemens PLM believes that the problem you reported where the Leader option in the Tabular Note dialog was set to "Leader from Top" when editing a Tabular Note regardless of the original setting used, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 68: NX_Errors - 8.5

2167983

Siemens PLM believes that the problem you reported where different results were observed when the Customer Default "Change Displayed Part on Close" was enabled, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2168065

Siemens PLM believes that the problem you reported where About Through Curves will be resolved by code changes made to the upcoming release of our software NX 8.5. The fixes must be protected by using version control. Thus the old feature needs to be either re-done or bring in for a interactive "edit" to get the fixes.

2168100

Siemens PLM believes that the problem you reported where PMI using expressions can not be shown from assembly using partial loading, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2168263

Siemens PLM believes that the problem you reported where the Style setting 'Leader from Top', 'Leader from Bottom' used for Leader Repositioning did not work correctly for Tabular notes or Parts Lists, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2168345

CAM Express doesnot work in SE ST3 assembly.

2168491

Siemens PLM believes that the problem you reported where Datum Feature alignment using "Position Relative to View" was not working in NX7.5, will be resolved by code changes made to the upcoming release of our software NX 7.5.5, NX 8.0.1 and NX 8.5.

2168611

Siemens PLM believes that the problem you reported where Measure distance get different result between part and assembly will be resolved by code changes made to the upcoming release of our software NX 8.5.

2168693

Siemens PLM believes that the problem you reported where Part Cleanup takes a long time for parametric parts will be resolved by code changes made to the upcoming release of our software NX 7.5.5 and later releases.

2168747

Error comes while opening solid edge part in CAM Express.

2168769

Siemens PLM believes that the problem you reported where the Datum:Scale is changed, an object cannot be displayed, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2169092

Siemens PLM believes that the problem you reported where Parts list behavior with locked rows and key field with leaves on. will be resolved by code changes made to the upcoming release of our software NX 8.5. The behavior reported by the PR is not a problem and per design. When the component referenced by the locked row is deleted, its parent component is the new leaf component and is automatically included into the parts list due to the 'Leaves Only' Edit Level setting. A new row is created for the component representing the new leaf. The original row has a strike through at this point, however, for a parts list that has no key columns: the new row is merged with the strike through row and the end result is a single new row that does not have strike through. On the other hand, for a parts list with a key column, the rows are not merged and the end result is two rows, the original row with a strike through and a new row for the new leaf component. A problem that is not explicitly mentioned is that although the parts list automatic update toggle setting was ON, an update of the parts list was required to see the final results.

21695 Siemens PLM believes that the problem you reported where a Boolean of two primitives was

Page 69: NX_Errors - 8.5

84 not reported in the Details pane of the Part Navigator will be resolved by code changes made to the upcoming release of our software NX 8.5.

2169740

Siemens PLM believes that the problem you reported where the, Miter Direction of Contour Flange is not correct, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2169910

Siemens PLM believes that the problem you reported where leaders were isolated from the symbols in custom PMI Note symbols will be resolved by code changes made to the upcoming release of our software NX 8.5.

2169956

Siemens PLM believes that the problem you reported where users cannot report the shortcut key of add-on command, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2170024

Siemens PLM believes that the problem you reported where there is an incorrect translation for the menu on the Orbit dialogue box will be resolved by code changes made to the upcoming release of our software NX 8.5.

2170242

75HNS-alpha Linear Path fails using rectangular space reservation.

2170252

Siemens PLM believes that the problem you reported where you were unable to create a JT data for NX envelope data, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2170309

Siemens PLM believes that the problem you reported where silhouettes of the model were not displayed having updated the drawing view, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2170425

Siemens PLM believes that the problem you reported where an internal error was raised when inserting a Detailed or Projected View in the Drafting application, if the geometry in the parent view was closed prior to inserting the view, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2170652

Invalid attempt to load library when executing Cam Express from Solid Edge ST3.

2170690

Siemens PLM believes that the problem you reported where a PMI dimension cannot be snapped to Grid in FRONT view, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2170839

Siemens PLM believes that the problem you reported where alignment of annotation was getting changed, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2170847

Siemens PLM believes that the problem you reported where The color of the extracted sheet changes with selected surface types will be resolved by code changes made to the upcoming release of our software NX 8.5.

2170997

Siemens PLM believes that the problem you reported where all extracted edges were removed when deleting a Group, will be resolved by code changes made to the upcoming release of our software NX 8.5.

21711 Siemens PLM believes that the problem you reported where generating a Variable Contour

Page 70: NX_Errors - 8.5

38 operation that uses "Optimized to Drive" tool axis produces the error "Attempt to free already free memory in Storage Manager" will be resolved by code changes made to the upcoming release of our software NX 7.5.5. In NX 8.0.5 when the current tool size for the Optimized to Drive Tool Axis fails to match the largest concave curvature of the Drive Geometry a warning dialog will appear stating this condition exists and you may need to use a smaller cutter or increase the Maximum Lead Angle.

2171252

An error comes while opening solid edge ST3 part in CAM Express 7.5.2.

2171351

Siemens PLM believes that the problem you reported where a component body disappeared after reattaching a sketch, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2171628

Siemens PLM believes that the problem you reported where the NXOpen.Annotations > CustomSymbolCollection > ToArray method threw an error "System.InvalidCastException" if the part contained any PmiCustomSymbol objects, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2171823

Siemens PLM believes that the problem you reported where the behavior of hiding a silhouette edge in a view needs to be documented will be resolved by code changes made to the upcoming release of our software NX 8.5.

2171871

Siemens PLM believes that the problem you reported where exporting a part raised the error "An invalid tag was passed to the tag module", will be resolved by code changes made to the upcoming release of our software NX 8.5.

2172029

"The problem where ""Part not found" error occurs with ugmanager_transfer_program" is fixed in release NX 8.5."

2172053

Siemens PLM believes that the problem you reported where animations do not stop when using the "Ctrl + Shift + L" keys will be resolved by code changes made to the upcoming release of our software NX 8.5. The combination "Ctrl + Shift + L" keys is only used on Linux devices to abort operations. On windows opening systems, selecting the "Stop" button in the Work-in-progress dialog is the correct method. The status line has been modified to only show this message on non-Windows machines.

2172392

Siemens PLM believes that the problem you reported where Smooth Edges were selectable, when the body was shaded with the Visualiation "Smooth Edges" toggled off, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2172484

Siemens PLM believes that the problem you reported where enhance requirement to NX Documentation to explain definition method of base point will be resolved by code changes made to the upcoming release of our software NX 8.5.

2172513

Siemens PLM believes that the problem you reported where using "Zoom" and then "Fit" five times in a row and the fifth operation is delayed, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2172696

Siemens PLM believes that the problem you reported where when using the Apply button on some dialogue boxes increases the size of the description area will be resolved by code changes made to the upcoming release of our software NX 7.5.5.

2172774

Siemens PLM believes that the problem you reported where Dimension locations changed when views were updated will be resolved by code changes made to the upcoming release of

Page 71: NX_Errors - 8.5

our software NX 8.5.

2172775

Siemens PLM believes that the problem you reported where certain PMI Dimension values changed when updating a view will be resolved by code changes made to the upcoming release of our software NX 8.5.

2172784

Siemens PLM believes that the problem you reported where the documentation was missing an explanation for how multiple revisions of UDF's are displayed in the User Defined Feature Library Browser, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2172892

Enhancement Request about Japanese localization of message.

2172893

Siemens PLM believes that the problem you reported where "Invalid path name" for Search Directories is displayed when Load From Folder will be resolved by code changes made to the upcoming release of our software NX 8.5.

2173060

CPJ-VUP: UAF/UAD Failure(NX8.0 ip21) - Offset Face is failed to update.

2173127

Siemens PLM believes that the problem you reported where an update error occurs when you reopen the file, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2173232

Joint origin is not updated after modeling change.

2173476

Siemens PLM believes that the problem you reported where the documentation for the NXOpen "GetVisibleExpressions()" method did not clearly explain that it only returns numeric expressions will be resolved by code changes made to the upcoming release of our software documentation NX 8.5.

2173512

Siemens PLM believes that the problem you reported where in a Wire EDM Sequence Internal Trim the Finish Trim operation ignores one of two Thread Holes that are defined will be resolved by code changes made to the upcoming release of our software NX 8.5.

2173646

Siemens PLM believes that the problem you reported where a Chamfer on an instanced hole incorrect, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2173772

Siemens PLM believes that the problem you reported where the GRIP command DIMBP/ created a bogus object will be resolved by code changes made to the upcoming release of our software NX 8.5.

2173826

Marker does not follow to the geometry change.

2173829

Siemens PLM believes that the problem you reported where the vector force does not follow the geometry change that is made by an expression modification will be resolved by code changes made to the upcoming release of our software NX Motion Simulation, version 8.5

2173912

Siemens PLM believes that the problem you reported where after copying and pasting a component, the Parts List cell value failed to change leaving "[...]" in the CALLOUT column will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 72: NX_Errors - 8.5

2173975

Siemens PLM believes that the problem you reported where the whole assembly was closed when the X button was clicked on the graphics window, will be resolved by code changes made to the upcoming release of our software NX 8.5. In NX 8.5 a choice is offered to the user if they want to close the "Part" or the "Part and its components" and depending on the user choice the action is performed.

2174060

Siemens PLM believes that the problem you reported where Inadequate Documentation for Start and End limitations for Extrude feature is fixed in NX 6 and later. From NX 6 onwards under all circumstances when a sketch is selected for Extrude, the Limits options now includes the Value, Symmetric Value, Until Selected, and Until Extended options.

2174064

Siemens PLM believes that the problem you reported where the behaviour is different from the circle created by Insert>Curves>Arc/circle and the circle created by Sketch will be clarified in NX8 documentation by the following change made to the Arc/Circle dialog box page: "End Option Lets you specify the point for the start angle of the arc or circle as a constraint."

2174340

Siemens PLM believes that the problem you reported where you want to add description of "UGII_UDF_LAYER_ORIGINAL", will be resolved by code changes made to the upcoming release of our software NX 8.5. It is by desgin that only essential environment variables are documented in the online Help. UGII_UDF_LAYER_ORIGINAL is not considered essential for most users and is therefore not included in the online Help. However, the definition for UGII_UDF_LAYER_ORIGINAL is found in the NX system copy of your ugii_env_ug.dat file, and is duplicated here: # UGII_UDF_LAYER_ORIGINAL specifies that all objects created by a new UDF instance will be by default added to the # layers where they are original created in the UDF definition part. Users can change to work layer or new layer # when inserting a UDF. To turn this on, set the value to 1. UGII_UDF_LAYER_ORIGINAL=0.

2174368

Siemens PLM believes that the problem you reported where Assembly Preferences Maintain works differently from the help file will be resolved by code changes made to the upcoming release of our software NX 8.5. The description of the Maintain preference now says: "Specifies that NX should try to keep the same work part when the displayed part is changed, assuming the work part is in the downstream hierarchy of the displayed part. "Note: When you make a component the displayed part, it becomes the work part as well. If the displayed part is an assembly, the work part can be the assembly or any of its subassemblies or components. "If this check box is not selected when the displayed part is changed, the displayed part becomes the work part."

2174386

Siemens PLM believes that the problem you reported where assigning a part number for an idealized part doesn't work will be resolved by code changes made to the upcoming release of our software NX 8.5. The behavior of the part number assignment was changed in NX 8.5. Once the user assign a number to a part, the "Assign" button will be grayed out to prevent the user from re-assigning the part number again. From now on, user can't repetitively click on the "Assign" button to re-assign the part number.

2174697

Siemens PLM believes that the problem you reported that documentation on hiding a sketch as opposed to making a sketch internal was ambiguous will be resolved by code changes made to NX 8.5. The documentation will be as follows: In the Part Navigator, NX places the sketch before its former owning feature. NX displays the sketch in the graphics window only if the sketch is on a visible layer. Note The visibility of sketches when you make them internal or external is independent of the Show and Hide command. The following has been added to the Internal and External sketches topic: Differences between Internal and External sketches Internal sketches are accessible only from the owning feature. They are not listed in the Part Navigator and are not displayed in the graphics window. Note If you want to only hide your sketch in the graphics window, use the Show and Hide command.

Page 73: NX_Errors - 8.5

2174711

Siemens PLM believes that the problem you reported where Results from Response Spectrum analysis could note be displayed in Advanced Simulation, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

2174777

Wants to remain a hidden sketch by "Make Sketch External".

2174785

Siemens PLM believes that the problem you reported where graphics for nodal force locations may be incorrect will be resolved by code changes made to the upcoming release of our software Femap NX 8.5.

2174990

Siemens PLM believes that the problem you reported where the NX-created folders are not deleted when NX is properly closed will be resolved by code changes made to the upcoming release of our software NX 8.5.

2175180

Siemens PLM believes that the problem you reported where the selected feature is released and is no longer selected will be resolved by code changes made to the upcoming release of our software NX 8.5.

2175374

Siemens PLM believes that the problem you reported where the documentation for durability was incorrect will be resolved by code changes made to the upcoming release of our software NX 8.5.

2175678

Siemens PLM believes that the problem you reported where the PMI Note dialog was not wide enough in the Custom Symbols area when running in Teamcenter managed NX, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2175938

Siemens PLM believes that the problem you reported where Force Save All does not create a preview in Teamcenter mode will be resolved by documentation changes made to the upcoming release of our software NX 8.5. "Force save all" causes all parts in the session to be saved even if they are not the displayed part or part of the displayed assembly. Only parts in the current displayed part/assembly have their previews updated. The session parts that are NOT in the current display do not get their previews created/re-created. Additional documentation has been added to describe the preview results on session parts that are displayed and not displayed.

2175998

Siemens PLM believes that the problem you reported when PMI objects are inherited to a drawing, some PMI objects are placed around the sheet origin will be resolved by code changes made to the upcoming release of our software NX 8.5.

2176008

NX/TC : Part file is opened from [Advanced Search], it becomes "Read Only".

2176009

Siemens PLM believes that the problem you reported where a UDF's children were not reported in Information Window, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2176013

Siemens PLM believes that the problem you reported where Cue line reads "Select a feature and parameter to reference", will be resolved by code changes made to the upcoming release of our software NX 8.5 and will then read "Select a feature and then select a parameter to reference.".

2176040

Siemens PLM believes that the problem you reported where a Flat Pattern did not update having changed a Draft Angle to 12 degrees, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 74: NX_Errors - 8.5

2176073

Siemens PLM believes that the problem you reported where copying a note to another layer and then deleting that copied note causing the original note to lose the understanding of how the leader on the note should look will be resolved by code changes made to NX 8.5.

2176102

Siemens PLM believes that the problem you reported where a detail view's boundary line thickness changes after the parent view's circle is moved will be resolved by code changes made to the upcoming release of our software NX 8.5.

2176103

Siemens PLM believes that the problem you reported where a Divide Face operation failed at the default modeling tolerance will be resolved by code changes made to the upcoming release of our software NX 8.5.

2176225

Siemens PLM believes that the problem you reported where Operation is different according to the selection sequence by "Subtract" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2176260

Siemens PLM believes that the problem you reported where the documentation did not explain that the UDF library configuration does not support duplicate folder names at the same level of the library hierarchy, will be resolved by documentation changes to the upcoming release of our software NX 8.5.

2176305

Siemens PLM believes that the problem you reported where inconsistent messages were raised for missing UDF Help documentation depending on if the user was inserting or editing a UDF, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2176360

Siemens PLM believes that the problem you reported where the leader of a label shows in NX when it is hidden in I-deas will be resolved by code changes made to the upcoming release of our software NX 8.0.3.

2176398

Siemens PLM believes that the problem you reported where the U and V Grid Count values for a component were "-1", will be resolved by code changes made to the upcoming release of our software NX 8.5. The U and V Grid Count fields will now be grayed out, unless a object which has U and V grid counts (which are solid and sheet bodies, and their faces) has been selected.

2176563

Siemens PLM believes that the problem you reported where the modified UDF part name in the UDF definition dialog is not picked up when the user does a MB2, will be resolved by code changes made to the upcoming release of our software NX 8.5. The error message is a check to see if there is already a UDF definition part with the given UDF part name. It is ok to have two identically named UDFs but with different UDF part names. The search for the right UDF is done using both UDF name and UDF part name.

2176621

Siemens PLM believes that the problem you reported where Alerts were displayed even when the preference was disabled, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2176744

Siemens PLM believes that the problem you reported where the selection bar is reset when F1 function key is used in an NX session that has UGII_FKEY_DYNAMICS environment varible set to 1 to simulate I-deas like behavior with the function keys will be resolved by code changes made to the upcoming release of our software NX 8.5.

2177022

Siemens PLM believes that the problem you reported where assembly level layer control was not honored with JT translations, will be resolved by code changes made to the upcoming release of our software NX 8.0.1, 8.5, and onward.

21770 Siemens PLM believes that the problem you reported where the documentation does not

Page 75: NX_Errors - 8.5

40 completely define the behavior of the 'Enlarge' command will be resolved by code changes made to the upcoming release of our software NX 8.5.

2177153

Siemens PLM believes that the problem you reported where About the difference in operation of the button of a Library Class Selection will be resolved by code changes made to the upcoming release of our software NX 8.5.

2177272

Siemens PLM believes that the problem you reported where Want to describe about the specification of quick pick in NX doc will be resolved by code changes made to the upcoming release of our software NX 8.5.

2177307

Siemens PLM believes that the problem you reported where some Core Drills retrieved from either the inch or metric tool library have the Flute Length longer than the Length will be resolved by code changes made to the upcoming release of our software NX 8.5.

2177325

Siemens PLM believes that the problem you reported where Routing Stock was not united automatically in one component, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2177437

Siemens PLM believes that the problem you reported where documentation was needed to describe the behavior when opening an ItemRev that contains both a UGMaster and a UGPart will be resolved by code changes made to the upcoming release of our software NX 8.5.

2177564

Siemens PLM believes that the problem you reported where a Scale operation on a label does not scale the arrow, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2177639

Siemens PLM believes that the problem you reported where Does using long expression name affect data will be resolved by code changes made to the upcoming release of our software NX 8.5.

2177655

Siemens PLM believes that the problem you reported where a Hem Flange could not be created will be resolved by code changes made to the upcoming release of our software NX 8.5.

2177696

Siemens PLM believes that the problem you reported where cylindrical surfaces were not divided when creating spot welds will be resolved by code changes made to the upcoming release of our software NX 8.5.

2177746

Siemens PLM believes that the problem you reported where there was a documentation error in "Add MY_END_MILLS tools to the database" where the "#END_DATA" was missing, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2177885

Siemens PLM believes that the problem you reported where the documentation was inadequate in describing the meaning of "Apply Name to All Occurrences" for the "Component Properties" form will be resolved by documentation changes made to NX 8.5 on this topic.

2177965

Siemens PLM believes that the problem you reported where the documentation for the Check-Mate function mqc_logObjectSet was insufficient, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

2177970

Siemens PLM believes that the problem you reported where Working in Japanese environment and getting error message in English, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 76: NX_Errors - 8.5

2178079

Siemens PLM believes that the problem you reported where the different formats in the UDF library files; dbc_udf_ascii.def and dbc_udf_ugmgr.def are unsupported, will be resolved by documentation changes made to the upcoming release of our software NX 8.5. The following note has been added to the documentation for "Setting Up and Managing UDF Libraries":

NOTE: You cannot configure both native and managed UDF libraries simultaneously.

2178080

Siemens PLM believes that the problem you reported where additional documentation was required for the environment variable "UGII_UDF_IMAN_WITH_NATIVE_DATABASE" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2178087

Siemens PLM believes that the problem you reported where setting the Show property on a Block Styler to False resulted in the Reset button not being shown, will be resolved by code changes made to the upcoming release of our software NX 8.5. The Show property has been disabled for a dialog.

2178262

Siemens PLM believes that the problem you reported where the Assemblies Help needed more description of the Synchronize Links options, especially of the columns for the Candidates Table in the dialog box, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2178299

Siemens PLM believes that the problem you reported where Maximum Clearance setting is changed into Minimum in the Measure Distance will be resolved by code changes made to the upcoming release of our software NX 8.5.

2178549

Siemens PLM believes that the problem you reported where the Help Documentation for Sketch curve offsets was incorrect will be resolved by code changes made to the upcoming release of our software NX 8.5.

2178563

Siemens PLM believes that the problem you reported where groups for a sheet were not displayed in the Part Navigator when using the supplied template, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2178888

CAM:Attempt to free already free memory in Storage Manager message is displayed.

2178946

Siemens PLM believes that the problem you reported where a Flat Solid could not be created will be resolved by code changes made to the upcoming release of our software NX 8.5.

2178966

Siemens PLM believes that the problem you reported where the Part Family Member (PFM) folder isn't created within the existing item number, will be resolved by corrections made to the documentation for the upcoming release of our software NX 8.5 In this use case the PFM Item and ItemRevision already exist so NX doesn't need to create anything. NX only places the PFM in the "Family folder" if it is a new Item in the database. The documentation has been updated as follows:  

Storage of Family Members in Teamcenter A family table is stored in Teamcenter with the template part for the family of parts. There are two situations when members of a part family are created in Teamcenter:

1. When you save an assembly that contains the family member in NX.2.  When you explicitly create the family member(s) using the PartFamily > Create Parts

command.

Page 77: NX_Errors - 8.5

When you save an assembly that contains a family member, if the family member is new, a new Item is created. That Item is then stored in a folder titled Family Members, which is attached to the template part by a references relationship. The default name for this folder is Family Members, or whatever the translation is from the variable gk_fam_memb_name. If, for any reason, the folder with the correct translated name does not exist, Teamcenter Integration will look for an existing folder called Family Members and use this instead. If the family member is revised, the existing database Item is also revised. If the member of the part family already exists in the database, that existing copy of the member is overwritten.

2178973

Siemens PLM believes that the problem you reported where the performance of a Divide Face command is slower in NX7.5 than in NX7 will be resolved by code changes made to the upcoming release of our software NX 8.5.

2179042

Siemens PLM believes that the problem you reported where information needed to be added to the documentation about the 'Special Paste' operation will be resolved by code changes made to the upcoming release of our software NX 8.5. The following note is added to the help: You can redo a paste operation only if the contents of the clipboard have not been changed. For example, if an additional copy operation is performed prior to the redo operation, the contents of the clipboard are considered invalid for a redo operation and the Redo command is not available for selection.

2179170

Siemens PLM believes that the problem you reported where a PMI Region was incorrectly displayed on a face will be resolved by code changes made to the upcoming release of our software NX 8.5.

2179175

Siemens PLM believes that the problem you reported where the "Update Customization" dialog in the Japanese version of NX contains unreadable characters will be resolved by code changes made to the upcoming release of our software NX 8.5.

2179216

Siemens PLM believes that the problem you reported where a Coincident Constraint was not created automatically depending on how the line was initiated, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2179276

Siemens PLM believes that the problem you reported where the balloon for "Remove Missing Parents" did not get raised when the cursor was placed over the black [X] icon, when editing a PMI Feature Control Frame, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2179312

Siemens PLM believes that the problem you reported where the Edge Blend documentation still made a reference to "Blend All Instances", will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

2179347

Siemens PLM believes that the problem you reported where the Face of the extension is cut by the plate Counterbore Hole will be resolved by code changes made to the upcoming release of our software NX 8.5. Note that old parts will not be modified in the new version of the software, but Hole Features created in the new version should exhibit the correct behavior.

2179373

Siemens PLM believes that the problem you reported where explanation about alerts is not available will be added in NX 8.5 Documentation. Added new text to the following info under Modeling->Part Navigator->Part Navigator - Main Panel help topic, in the Alerts section:Alerts Lists information or warning messages that display while creating or editing features. Alerts are temporary and appear only once with the initiating event and usually disappear following another action, such as a Playback or a subsequent edit, even when the condition that caused the alert message remains. [icon] Information alert - Indicates a non-serious event

Page 78: NX_Errors - 8.5

that does not require any user interaction. Example: Preview could not be computed. [icon] Warning alert - Indicates a serious problem with the current operation, and requires user interaction to correct the problem. Example: Unable to terminate the blend faces. Add adjacent tangent edges or all the edges of the vertex.

2179697

Siemens PLM believes that the problem you reported where the X button became available when exiting the sketch even when the button, UG_FILE_SAVEAS_AND_CLOSE was removed from the menuscript file will be resolved by code changes made to the upcoming release of our software NX 8.5.

2179713

Siemens PLM believes that the problem you reported where the message displayed when creating a new revision incorrectly referred to an existing part in the database that did not exist, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2179881

Siemens PLM believes that the problem you reported where after generating a Flowcut operation and selecting 'OK' to the dialog the status changes to "Regenerate" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2179958

Siemens PLM believes that the problem you reported where Clearance Analysis can fail to detect some bodies that are not members of the MODEL reference set will be resolved by code changes made to NX 8.5.

2180150

Siemens PLM believes that the problem you reported where a warning is generated when a 2 byte character is input in the "Holding Systems Name" field in MCT-POCKET/Pocket when using the UGII_LANG=Japanese variable will be resolved by code changes made to the upcoming release of our software NX 8.5

2180303

Siemens PLM believes that the problem you reported where "update NX Documentation about UDF/tcl file usage" is fixed in NX 8.5 Documentation In the Modeling help for UDF, the following statement is to the topic, "Managing UDF Libraries from Native": "NX always uses the tcl file, one for Native and one for Teamcenter, located in the installation folder."

2180373

Siemens PLM believes that the problem you reported where the manual does not explain how the "Average Pressure" is calculated in the report will be resolved by code changes made to the upcoming release of our software in NX Advanced Simulation Version 8.5. The documentation was updated for NX 8.5 release. The average pressure is the arithmetic average of all nodal pressure for the selected elements.

2180375

Siemens PLM believes that the problem you reported where a stationary face is incorrect will be resolved by code changes made to the upcoming release of our software NX 8.5.

2180631

Siemens PLM believes that the problem you reported where there is no description of the behavior for automatic anchor point in the Drafting Help will be resolved by code changes made to the upcoming release of our product NX 8.5. Additional information is added to the definition of the anchor point option on the General tab of the View Preferences dialog box.

2180733

Siemens PLM believes that the problem you reported where an "Internal error" is returned if you specify the Approach Point in an Avoidance group then generate an operation from the Operation Navigator in Turning, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2180767

Siemens PLM believes that the problem you reported where a performance loss was observed when loading materials in a part, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 79: NX_Errors - 8.5

2180874

Siemens PLM believes that the problem you reported where reattach sketch doesn't attach constraints properly, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2180913

Siemens PLM believes that the problem you reported where a preview can be selected as if it is a real section object will be resolved by code changes made to NX 8.5.

2180956

Siemens PLM believes that the problem you reported where the spot welding function created duplicate elements will be resolved by code changes made to the upcoming release of our software NX 8.5.

2181072

Siemens PLM believes that the problem you reported where an NX 7.5.2 Area Milling operation generates in NX 7.5.4 with spikes in the tool path will be resolved by code changes made to the upcoming release of our software NX 8.5.

2181073

Siemens PLM believes that the problem you reported where the assembly drawing with PMI produces saving error will be resolved by code changes made to the upcoming release of our software NX 8.5.

2181185

ISZ_VUP The master which is directly under ALTREP cannot be loaded.

2181202

Siemens PLM believes that the problem you reported where Advanced Simulation application was disabling the Delete Selected and Hide Selected buttons on the Modeling application's mb3 popup menu will be resolved by code changes made to the upcoming release of our software NX 8.5.

2181206

Siemens PLM believes that the problem you reported where the "Base Edge" could not be selected when adding a "Bend Flange", will be resolved by code changes made to the upcoming release of our software NX 8.5.

2181409

Siemens PLM believes that the problem you reported where Instanced geometry is not visible even when unsuppressed by expression, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2181473

Siemens PLM believes that the problem you reported where NX Nastran results are not available after solving the PTS will be resolved by code changes made to the upcoming release of our software NX 8.5 phase 11.

2181649

Siemens PLM believes that the problem you reported where there is documentation for "File > Import NX-2D", however there is no such function available in the software, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2181756

Siemens PLM believes that the problem you reported where PMI dimensions lose sight of reference when adding view to drawing, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2181774

Siemens PLM believes that the problem you reported where missing additional info in NX's docs:"the reason why some characters are unsupported" will be updated in the upcoming release of our software documentation NX 8.5 The following information is added. Because of operating system limitations, NX does not support non-ASCII characters, including 8-bit accented Western European and multi-byte characters, in file names.

21818 Siemens PLM believes that the problem you reported where resetting the Point dialog, while

Page 80: NX_Errors - 8.5

09 importing a part into drafting, does not reset the Co-ordinates, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2181817

Siemens PLM believes that the problem you reported where an Internal Error occurs when performing a 'Preferences -->View' command will be resolved by code changes made to the upcoming release of our software NX 8.5. For existing drawings it will be important to run a Part CleanUp.

2181974

Siemens PLM believes that the problem you reported where a more complete description of an atypical thread is needed in the definition of the Render True Hidden Line option will be resolved by code changes made to the upcoming release of our software NX 8.5. The Render True Hidden Line option is redefined as: "Increases the quality of the rendered thread so that incorrectly trimmed thread lines appear correctly. When set, the time it takes to display the view may increase when there are numerous threads."

2182038

Siemens PLM believes that the problem you reported where deleting Routing parts using the read only Stock As Components causes an aborted NX session will be resolved by code changes made to the upcoming release of our software NX 8.5.

2182150

Siemens PLM believes that the problem you reported where the drag handle of a 3D Angle constraint is in the wrong direction, will be resolved by code changes made to the upcoming release of our software NX 8.5. The drag handle is still created in the same direction because the original configuration of geometries does not yield a unique direction but once the geometries are rotated the drag handle is updated.

2182151

Siemens PLM believes that the problem you reported where A highlight of Constraints disappears in "Show/Remove Constraints" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2182163

Siemens PLM believes that the problem you reported where an error occurred if a CheckMate Home Folder was in Japanese notation, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2182254

Siemens PLM believes that the problem you reported where the documentation did not contain sufficient information about "Active Feature Group",will be resolved by code changes made to the upcoming release of our software NX 8.5 documentation. The following topics on the Feature Group dialog have been added in the Modeling help:

1. Added the option for "Make this Group Active" to the options table and added this text: "Makes the selected Feature Group the Active Feature Group. When a Feature Group is active, all newly created features are automatically added to that group. You can also right-click a Feature Group in the Part Navigator and choose Make This Group Active."

2. Since this project seemed to have been missed back in NX 8, Development also added one other new option on the dialog box that was added in that release: New Feature Group Position.

3. Also added some additional new capabilities to the Embed Feature Group Members option.

2182336

Siemens PLM believes that the problem you reported where the Show() method for the Block UI Styler needed better documentation will be resolved by code changes made to the upcoming release of our software NX 8.5.

2182338

CPJ:Document:No info about "Active Feature Group".

Page 81: NX_Errors - 8.5

2182554

Siemens PLM believes that the problem you reported where additional examples are needed for ug_clone will be resolved by code changes made to the upcoming release of our software NX 8.5.

2182566

Siemens PLM believes that the problem you reported where using Analysis Shape Section and pressing "Show Result" of an Aesthetic Face Blend is not reported, will be resolved by code changes made to the upcoming release of our software NX 8.5. Added the following text to the "Aesthetic Face Blend options" topic the NX 8.5 Help (documentation): Show Result Shows the result that will be produced when the Aesthetic Face Blend command is completed. Click Undo Result to return to the normal view.

NOTE: If you create a Section Analysis while Show Result is active, both face chain 1 and face chain 2, as well as the previewed Aesthetic Face Blend, are all selected for the displayed section analysis. You can select and de-select any of the faces during the analysis display.

2182695

Siemens PLM believes that the problem you reported where the 'Select All' function in the Class Selection dialog discovers objects that should have been rejected by the current filter settings will be resolved by code changes made to the upcoming release of our software NX 8.5.

2182756

Siemens PLM believes that the problem you reported where the "Display Selected Objects" option causes an Internal Error will be resolved by code changes made to the upcoming releases of our software NX 7.5.5 MP1 and NX 8.0.1.

2182943

Siemens PLM believes that the problem you reported where adding a PTS part did not position the part in the expected location, while working in assembly context, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2182966

Siemens PLM believes that the problem you reported where " Arc of Threaded Hole not added to a Reference Set when body is copied" is fixed in release NX 8.5.

2182986

Siemens PLM believes that the problem you reported where "Failed to update offset Region" will be resolved by code changes made to the upcoming release of our software "NX 8.5 ip13".

2182991

Siemens PLM believes that the problem you reported where "Failed to update Move Face" will be resolved by code changes made to the upcoming release of our software NX 8.5 phase 15. But to make the operation to succeed, we need recreate the move face feature or edit the move face feature and change Overflow Behaviour from Automatic to Extend Change Face option.

2183016

Siemens PLM believes that the problem you reported where "Replace Face failed to update" will be resolved by code changes made to the upcoming release of our software NX 8.5 ip17.

2183119

Siemens PLM believes that the problem you reported where a constraint dimension did not update to the correct location after editing will be resolved by code changes made to the upcoming release of our software NX 8.5.

2183225

Siemens PLM believes that the problem you reported where a Hub semi-finish operation creates the wrong motion in NX 8 compared to NX 7.5.3 will be resolved by code changes made to the upcoming release of our software NX 8.5. The issue reported in this PR was that the tool path in NX 7.5.3 succeeded to cut the entire hub, on NX 8.0, the path was trimmed in the middle and the tool axis orientation at the trailing edge was wrong. in NX 8.5 we had a project to enhance the success rate of the system to cut through the entire path by allowing changes in the lead/lag direction. Both issues reported here are fixed by this project. In this particular case I'd also recommend to change the extension settings at the leading edge to

Page 82: NX_Errors - 8.5

control the overlap between instances. Also when switching to NX 8.5 the stepovers need to be reconsidered.

2183277

Siemens PLM believes that the problem you reported where an NX 7.5.3 Hub Finish operation generated in NX 8 MP1 produces different tool axis output will be resolved by code changes made to the upcoming release of our software NX 8.5.

2183281

Siemens PLM believes that the problem you reported where Preview incorrectly displayed threads only when creating a Thread in History Free Mode, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2183328

Siemens PLM believes that the problem you reported where it is impossible to output "Ruler Angle_3" will be resolved by code changes made to the upcoming release of our software NX Motion Simulation, version 8.5.

2183383

Siemens PLM believes that the problem you reported where values of a Surface Finish Symbol could not be edited when using a blank template and the ESKD Drafting Standard, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2183385

Siemens PLM believes that the problem you reported where "New" text is corrupted in the Compound Datum Reference dialog, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2183394

Siemens PLM Software believes that the problem you reported where save errors appear if members are used from a UDF Reuse Library with a pathway that exceeds 132 characters will be resolved by code changes made to NX 8.5.

2183458

Siemens PLM believes that the problem you reported where a gap occurred between an FCF box and its leader when Custom Zone is on fixed in NX 8.5.

2183535

Siemens PLM believes that the problem you reported where the Assemblies Help needed to include a note that Component-Component and Component-Datum mating constraints are not included in an assembly constraints conversion, because those constraints are used by component arrays, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2183605

Siemens PLM believes that the problem you reported where Crosshatch cannot select a "Surface Finish Symbol" for Annotation to Exclude will be resolved by code changes made to the upcoming release of our software NX 8.5.

2183646

Siemens PLM believes that the problem you reported where the user cannot edit the value of "Threshold" on the Measure command will be resolved by code changes made to the upcoming release of our software NX 8.5.

2183697

Siemens PLM believes that the problem you reported where even though no changes are made, the Sketch reports errors will be resolved by code changes made to the upcoming release of our software NX 8.5.

2183702

Siemens PLM believes that the problem you reported where no projection curve is created if the projection plane is made smaller will be resolved by code changes made to the upcoming release of our software NX 8.5.

2183715

Siemens PLM believes that the problem you reported where " NX takes more time to create new group when the group tree in part navigator " is fixed in release NX 8.5.

Page 83: NX_Errors - 8.5

2183767

Siemens PLM believes that the problem you reported where Lagrangian Interpolate function in Function Single Math has Ordinate value corresponding to maximum abscissa value wrong will be resolved by code changes made to the upcoming release of our software NX 8.5.

2183828

Siemens PLM believes that the problem you reported where Remove Parameters raised an internal error, will be resolved by code changes made to the upcoming release of our software NX 8.5. A Part Cleanup (Feature Data) in NX 8.5 allows for the parameters to be removed correctly and no Error occurs.

2183921

Siemens PLM believes that the problem you reported where there seems to be issues with acceleration and deceleration will be resolved by code changes made to the upcoming release of our software NX 8.5. The documentation and turning team have together continued their work on the problem you reported and initiated further steps to accordingly enhance the turning documentation. The following describes our recommendations for your PR part file: The simplest way to eliminate the unwanted deceleration feed rate move is to eliminate the ramp. To do so, set a deceleration distance limiting value in the accelerate/decelerate group. Select the Minimum length check box, which is the only widget in the group until it is selected. The minimum length text box appears and accepts a distance for the smallest ramp motion to be output, which you need only set to some value that is more than the length of the unwanted move. This resolves your reported issue.

2183959

Siemens PLM believes that the request you have reported to add more descriptive help information on "Constant Length" and "Constant Angle" will be added to the upcoming release of our product NX 8.5.

2184026

Siemens PLM believes that the problem you reported where rectangle selection was not working when selecting a Studio Spline, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184082

Siemens PLM believes that the problem you reported where there were extra lines showing in an Artistic Image, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184121

Siemens PLM believes that the problem you reported where the Help Documentation for Variable Offset was not correct will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184124

Siemens PLM believes that the problem you reported where welding licenses were not being managed in Welding preferences will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184156

Siemens PLM believes that the problem you reported where NX starts updating features from a much earlier feature than the current feature, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184168

Siemens PLM believes that the problem you reported where the category, 'Form Features', was not listed as a feature category in the NX Help documentation will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184186

Siemens PLM believes that the problem you reported where the Dimension Reference toggle was not available for a Driving Dimension in an active Sketch, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184208

Siemens PLM believes that the problem you reported where Setting Bend Relief to Round for Jog feature raises an alert will be resolved by code changes made to the upcoming release of

Page 84: NX_Errors - 8.5

our software NX 8.5.

2184265

Siemens PLM believes that the problem you reported where Hidden Wireframe preview style doesn't work in View Creation Wizard will be resolved by code changes made to the upcoming release of our software NX 8.5

2184368

Siemens PLM believes that the problem you reported where a Solid body cannot be selected with the unfolded view, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184382

Siemens PLM believes that the problem you reported where Finite Element Model Check is erroring out for Gap element orientation vector if a csys is used to define this vector will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184401

Siemens PLM believes that the problem you reported where the Japanese translation of Back is not correct in the "View Creation Wizard" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184421

Siemens PLM believes that the problem you reported where the result displayed was changed by selecting a template will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184480

Siemens PLM believes that the problem you reported where it was not possible to select an existing point with the Specify Point block in a .FEM part will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184725

NX/TC : Part file is opened from [Advanced Search], The file doesn't open.

2184761

Siemens PLM believes that the problem you reported where, the category of layers is not displayed with NX 7.5,will be resolved by code changes made to the upcoming release of our software, NX 8.5.

2184830

Siemens PLM believes that the problem you reported where an X-Form feature cannot be updated with the dynamic update modeling preferences set to incremental or continuous will be resolved by code changes made to NX 8.5.

2184848

Siemens PLM believes that the problem you reported where the Teach Mode Sub Operation menu specifies a Stepover as the feedrate will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184853

Siemens PLM believes that the problem you reported where "Overlay CGM" was setting the Anotation Preference color for General text, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184856

Siemens PLM believes that the problem you reported where the child-parent relationship of a body was not displayed in the Dependencies of the Part Navigator, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184894

Siemens PLM believes that the problem you reported where the "Use Hardware Rendering" documentation when creating animations. will be resolved by code changes made to the upcoming release of our software NX 8.5. The documentation for "Use Hardware Rendering" will be corrected to add information regarding how it is created and its quality as follows: This option creates each animation frame image by capturing the display directly from the graphics window in whichever real-time hardware rendering style is enabled (Shaded, Studio, etc). That

Page 85: NX_Errors - 8.5

is, the images are copied from the graphics window and not from the photo-realistic high quality image generation. Because the images are simply captured and not generated, the animations can be created more quickly. However note that the visual quality is less than that of animations created using high quality images. Tip: Use the Advanced Studio rendering style mode to get the best animation results with the Use Hardware Rendering option. The Advanced Studio display is similar to that of high quality images. But is not an exact match since not all the high-end visualization features that are supported by the photo-realistic high quality image rendering can be supported by the Advanced Studio display.

2184916

Siemens PLM believes that the problem you reported where forces are unevenly and incorrectly distributed by torque will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184917

Siemens PLM believes that the problem you reported where "When the angle of the Match Face in [Flange] changes the Flange shape also changes" is fixed in release NX 8.5. User should delete the existing flange and create new one in NX 8.5. For Flanges created in NX 8 or NX 8.0.x; there is a work around to avoid the problem.

1. In PR steps user modified the draft angle by edit->rollback of the draft feature. Instead if user change the draft angle from the "Details" window in part navigator, then flange updates without any problem.

2. The second work around is to suppress & un-suppress the flange after changing the draft angle. These work-a-rounds are effective in NX 8, NX 8.0.x & NX 8.5.   

2184934

Siemens PLM believes that the problem you reported where the characters on the "Draping Data" dialog are garbled in a Japanese environment. will be resolved by code changes made to the upcoming release of our software NX 8.5.

2184936

Siemens PLM believes that the problem you reported where an incorrect translation occurred for the menu on the "Joule Heating" dialog, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

2184943

Siemens PLM believes that the problem you reported where " Incorrect behaviour using close part when only component is modified" is fixed in release NX 8.5.

2185153

Siemens PLM believes that the problem you reported where the 'Preview' option for Streamline is missing in NX 7.5.5 & NX 8.0.1 will be resolved by code changes made to the upcoming release of our software in release NX 8.5.

2185189

Siemens PLM believes that the problem you reported where saving a drawing caused the 'Insert -> View' functions to be grayed out will be resolved by code changes made to the upcoming release of our software NX 8.5.

2185233

The problem where about System Fault Tolerance of Offset Surface is fixed in release NX 8.5.

2185237

Siemens PLM believes that the problem you reported where a Unite boolean caused Specific Translucency settings to become disabled in NX 7.5.4, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2185261

Siemens PLM believes that the problem you reported where the "Shortest Tool Length" column in the Operation Navigator reports incorrect results for Zlevel and Cavity Milling operations will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 86: NX_Errors - 8.5

2185263

Siemens PLM believes that the problem you reported where In certain cases, "Note" Dialog be hidden will be resolved by code changes made to the upcoming release of our software NX 8.5.

2186120

Siemens PLM believes that the problem you reported where a Move Face feature failed update, reporting: "The change failed because a vertex could not adapt", will be resolved by code changes made to the upcoming release of our software NX 8.5.

2186150

Siemens PLM believes that the problem you reported where Starting of the Addendum section dialog is very slow to respond will be resolved by code changes made to the upcoming release of our software NX 8.0.1.5 MP1, NX 8.0.2, and NX 8.5.

2186247

Siemens PLM believes that the problem you reported where an error is raised when the "Number of Desired Modes" is blank for the MSC Nastran environment, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

2186249

Siemens PLM believes that the problem you reported where Japanese characters can't be used in folder names will be resolved by code changes made to the upcoming release of our software NX 8.5.

2186337

Siemens PLM believes that the problem you reported where the property of an integer could not be added to the search criteria of Advanced Search, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2186342

Siemens PLM believes that the problem you reported where some features were out of date after using copy/paste on a body, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2186382

Siemens PLM believes that the problem you reported where examples/sample cases for one of the options in the Die Engineering Trim Line Output dialog box topic were missing from the documentation, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2186448

Siemens PLM believes that the problem you reported where both area selection and "Select All" option not being available for element selection in the fem file will be resolved by code changes made to the upcoming release of our software NX 8.5.

2186467

Siemens PLM believes that the problem you reported where the Assemblies Help needed details about the tolerance that is applied to radii involved in a Fit constraint will be resolved by code changes made to the upcoming release of our software NX 8.5. A Fit constraint uses a tolerance when determining whether radii are equal. For cylindrical faces (and most other geometries that are valid for a Fit constraint), a difference in radius of 0.1 mm or less is allowed. For conical faces, the tolerance is 1 degree. Because there are two cylindrical faces in the situation described in this PR, the Fit constraint works when the combined difference in radii is no more than 0.2 mm. When it is 0.3 mm, the Fit constraint cannot be applied.

2186468

Siemens PLM believes that the problem you reported where the message "Addendum type is not appropriate" is returned will be resolved by code changes made to the upcoming release of our software NX 8.0.2 and NX 8.5.

2186504

Siemens PLM believes that the problem you reported where Cancel button works like OK button in Constraint Navigator Properties dialog will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 87: NX_Errors - 8.5

2186581

Siemens PLM believes that the problem you reported where a Unite boolean operation failed reporting: "Thru face does not intersect path of the tool", will be resolved by code changes made to the upcoming release of our software NX 8.5.

2186793

Siemens PLM believes that the problem you reported where the file size of a .dlx file of a Block Styler dialog grew each time a property was modified, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2186842

Siemens PLM believes that the problem you reported where a Subtract Boolean changed the Target Body layer, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2186857

Siemens PLM believes that the problem you reported where a user cannot move a component relative to a selected face will be resolved by code changes made to the upcoming release of our software NX 8.5.

2186912

Siemens PLM believes that the problem you reported where f it switches to a full-scrn display, all custom tool bars will be disp will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187019

Siemens PLM believes that the problem you reported where the Show All Views in Drawing did not correctly show/hide views on different sheets, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187109

Siemens PLM believes that the problem you reported where a TIFF image did not display in the Member Select pane for a Custom Symbol will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187110

Siemens PLM believes that the problem you reported where a Note Title was not retained during custom symbol creation, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187111

Siemens PLM believes that the problem you reported where documentation was needed to describe the Rule option for the Define Custom Symbol operation will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187112

Siemens PLM believes that the problem you reported where "UNC" of Screw type is not displayed correctly will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187125

Siemens PLM believes that the problem you reported where when editing a Fixed Contour operation - a CSYS is displayed for a brief moment. will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187192

Siemens PLM believes that the problem you reported where PS25.00.104 fix. Move face failed in NX 8 will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187197

CPJ:"Surface Finish Symbol" macro does not work by using Reset.

2187214

Siemens PLM believes that the problem you reported where When I measure the curve, the color of the curve was changed. will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 88: NX_Errors - 8.5

2187237

Siemens PLM believes that the problem you reported where Rendering style of new parent are not inherited from the child part will be resolved by code changes made to the upcoming release of our software NX 8.5 by updating the NX Help doc to explain that Create New Parent uses the new-part template to determine the units, rendering style, and background color of the new parent part.

2187238

"Create New Parent" in native mode does not inherit what documentation indicates.

2187255

Siemens PLM believes that the problem you reported where NX takes too long to open a file will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

2187462

Siemens PLM believes that the problem you reported where the Japanese translation on the exciter command form will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187463

Siemens PLM believes that the problem you reported where there are incorrect Japanese characters in the Laminate/Extrude command will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187464

Siemens PLM believes that the problem you reported where there was an incorrect translation on the Laminate form will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187465

Siemens PLM believes that the problem you reported where there was incorrect Japanese translation on the GlobalLaminate command will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187466

Siemens PLM believes that the problem you reported where,There are incorrect Japanese while editing the graph in NX 8.0.0.2.5,will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187467

Siemens PLM believes that the problem you reported where a certain Parasolid file could not be opened in NX will be resolved by code changes made to NX 8.5.

2187469

Siemens PLM believes that the problem you reported where the Japanese HighResolution command is not translated correctly will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187479

Siemens PLM believes that the problem you reported where editing an X-Form feature failed with Dynamic Update set to Incremental or Continuous, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187577

Siemens PLM believes that the problem you reported where the message about "Marker" displayed by the "Model Check" command will be resolved by code changes made to the upcoming release of our software NX  8.5.

2187588

Siemens PLM believes that the problem you reported where the Result Processing using the group is not possible will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187598

Siemens PLM believes that the problem you reported where the tooltips of the "Reuse Library Management" dialog were garbled when translated to Japanese, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 89: NX_Errors - 8.5

2187622

Siemens PLM believes that the problem you reported where Objects are added to NX layers already used during DXF/DWG Import, will be resolved by code changes made to the upcoming release of our software NX 8.5. This behaviour was As Designed but the text string on the UI and documentation were misleading. Updated the text string on the UI and documentation as well in NX 8.5.

2187680

Siemens PLM believes that the problem you reported where the message "Restore Data was Reset by this Operation" was not displayed in the NX Status when Fit was selected from a toolbar, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187707

Siemens PLM believes that the problem you reported where the Plug/Slot dialog name was not translated in Japanese NX, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187715

Siemens PLM believes that the problem you reported where the Model Check command does not output a message about "Point On Curve" will be resolved by code changes made to the upcoming release of our software NX Motion Simulation, version 8.5. Development indicated, when the geometry used by point on curve is suppressed, Model Check will report an error stating that geometry is missing.

2187787

Duplicate Turning pass generated in a combined Roughing and Finishing operation.

2187983

Siemens PLM believes that the problem you reported where Welding Joint, Create Method: From Attributes, is not always available will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187987

Siemens PLM believes that the problem you reported where the Back command did not work properly in Welding Joint dialog will be resolved by code changes made to the upcoming release of our software NX 8.5.

2187992

Siemens PLM believes that the problem you reported where the Alerts Message was raised when selecting Define Joint Parameters, will be resolved by code changes made to the upcoming release of our software NX 8.5. In NX 8.5 when you choose the Define Joint Parameters button you now receive an alert "Thickness not defined for welding joint". What this means is that the darker blue body needs an attribute with the name shown in "Customer Defaults -> Structure Welding -> Common -> Body Thickness Attribute Title". For example, if the value in the customer default is "SAW_THICKNESS", and in this data case if an attribute named "SAW_THICKNESS" is added with a value of 2 to the darker blue solid body then "Define Joint Parameters" can be used.

2187994

Siemens PLM believes that the problem you reported where Edges are not modified when using the Weld Preparations will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188032

Siemens PLM believes that the problem you reported where PTS failed to catch a syntax error for Visibility Control, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188057

Siemens PLM believes that the problem you reported where Sketch is active when return to Drafting from Modeling will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 90: NX_Errors - 8.5

2188097

Siemens PLM believes that the problem you reported where a mirrored operation results in bad initial display of the copied path, but regenerating the operation is correct, will be resolved by code changes made to the upcoming release of our software in NX 8.5.

2188154

Siemens PLM believes that the problem you reported where a Face Blend could not be created, or produces an incorrect result. using the option "Orient Cross Section by Isoparameter Lines", will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188169

Siemens PLM believes that the problem you reported where there seems to be a restriction for the character in arrangement name will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188205

Siemens PLM believes that the problem you reported where an internal error appears when copying a curve under certain conditions of using UDF standard library countersunk holes when running NX with Teamcenter will be resolved by code changes made to NX 8.5.

2188299

Siemens PLM believes that the problem you reported where editing an edge curve length returned an error message will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188310

Siemens PLM believes that the problem you reported where in the documentation for the Evaluation Time option the list of supported solution sequences incorrectly included SOL 106 will be resolved by code changes made to the upcoming release of our product NX 8.5.

2188317

Siemens PLM believes that the problem you reported where Composite Curves could not get the correct maximum distance measurement will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188326

Siemens PLM believes that the problem you reported where the log decade setting was altering the graph overhead percentage will be resolved by code changes made to the upcoming release of our software NX 8.5. The old design is to calculate overhead firstly then calculate the decades, so the decades will be kept with the setting, but the overhead will hide the data. New design is to calculate decades firstly then calculate overhead, so the overhead will be consistent with the setting, but the decades setting will not be kept. This is also consistent with the design for decades with 0 (auto).

2188380

Siemens PLM believes that the problem you reported where "SECOFFSET" is not imported correctly from an ANSYS input file will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188393

Siemens PLM believes that the problem you reported where the setting concerning "Welcome" page of drafting doesn't become effective, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188412

Siemens PLM believes that the problem you reported where the Boundary Condition toolbar drop-downs contain the wrong list of types after canceling out of the Solution dialog will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188421

Siemens PLM believes that the problem you reported where blank spaces were appearing in the header of 103 response simulation results will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188423

Setting of the transparency is not reflected in Boolean.

Page 91: NX_Errors - 8.5

2188424

Siemens PLM believes that the problem you reported where the documentation for the refile_part utility did not coincide with the switch list in the utility, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188428

Siemens PLM believes that the problem you reported where the Customer Defaults did not have the same checking as the Sketch Preferences dialog (for Name Prefixes), will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188502

Siemens PLM believes that the problem you reported where if you have "Display Selected Objects" on and you use the "Tilt Tool Axis" option, you are no longer able to refresh the display screen will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188527

Siemens PLM believes that the problem you reported where using Undo after deleting a Trace in an NXOpen program will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188530

Siemens PLM believes that the problem you reported where Modify extrude section string created connected curves not working will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188599

PMI_section_cannot be properly edited.

2188605

Siemens PLM believes that the problem you reported where the documentation did not make it clear that there are no subtypes for leader objects will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188617

Siemens PLM believes that the problem you reported where the Manufacturing Preferences dialog still lists the Auto Block color although this color is no longer used by the system will be resolved by code changes made to the upcoming release of our software in NX 8.5. The corresponding preference has been removed from the dialog.

2188626

CAM:Garbled characters occur in a Update Customization dialog.

2188631

Component doesn't open when opening altrep Assembly.

2188656

Siemens PLM believes that the problem you reported where,a"Free Coincident" is replaced without message by manual creation,will be resolved by code changes made to the upcoming release of our software, NX 8.5.

2188660

Siemens PLM believes that the problem you reported where the phrase "complex modes" is not translated into Japanese properly will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188737

Siemens PLM believes that the problem you reported where Editing Element size after highlighting the elements causes an error will be resolved by code changes made to the upcoming release of our software NX 8.5. The user function UF_DISP_set_highlight() was never designed to support node and element highlighting, and the fact that it accidentally worked for several releases was un-intentional and the source of potential crashes. The routine has been modified to exclude nodes and elements. They are not full-fledged displayable objects for which this routine was designed.

Page 92: NX_Errors - 8.5

2188778

Siemens PLM believes that the problem you reported where in a "Clearance_Plane" sub-operation of a Probing operation, the "Automatic Plane" option does not cause the tool to move to the defined clearance plane in subsequent sub-operations will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188781

Siemens PLM believes that the problem you reported where Follow Part Offset and Follow Curve GMC moves didn't use the custom feed settings will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188833

Siemens PLM believes that the problem you reported where the Develop Trim Line feature is not working correctly will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188839

Siemens PLM believes that the problem you reported where the Stock Fold command raised the error: "Parasolid fold body does not exist", will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188847

Siemens PLM believes that the problem you reported where the "Spikes/Plunge Motion" selection filter in the toolpath editor does not work will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188855

Coordinates Reset doesn't work while import part to Drafting.

2188869

Siemens PLM believes that the problem you reported where the "Align with Arrows" option does not work for Drafting dimensions, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188941

Siemens PLM believes that the problem you reported where PMI dimension did not resize as set by Resize on Create setting will be resolved by code changes made to the upcoming release of our software NX 8.5.

2188975

Siemens PLM believes that the problem you reported where global shaping fails for sheets with gaps will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189066

Siemens PLM believes that the problem you reported where an unexpected gap is generated between the Trim Line and the Addendum Face when developing a trim line, will be resolved by code changes made to the upcoming release of our software NX 8.0.3 and NX 8.5.

2189082

Layer category set in part file is not reflected.

2189083

Layer category set in i-part is not reflected to fem and sim file.

2189084

Changing global depth of cut does not affect ranges.

2189092

Siemens PLM believes that the problem you reported where the message Null Tag Not Allowed was reported when MB3 was used to select a previous parent of a Projected View will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189097

Siemens PLM believes that the problem you reported where Suppress by Expression is not working correctly will be resolved by code changes made to the upcoming release of our

Page 93: NX_Errors - 8.5

software NX 8.5.

2189154

Siemens PLM believes that the problem you reported where Negative Tolerance values [Intol] and [Outtol] can be input into WEDM geometry UI will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189172

Siemens PLM believes that the problem you reported where Axial/Radial Clearance Planes are not displayed in Centerline Drilling after NX 5 will be resolved by code changes made to the upcoming release of our software in NX 8.5.

2189175

Siemens PLM believes that the problem you reported where Does not Dynamic Update, When you used the Falloff Scale of X-form will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189179

Siemens PLM believes that the problem you reported where NX Part location changed after exporting to JT, will be resolved by changes made to the upcoming release of our software NX 8.5.

2189195

Siemens PLM believes that the problem you reported where edit studio spline by X-Form, changes spline size by de-selecting object, will be resolved by code changes made to the upcoming release of our software NX 8.5. The reason such spline in this part file becomes shorter in Xform is because they are Through Points Spline with extension. In xform we need to convert such spline to Spline By Poles, as a result, the extension information can't be kept, so the shorter spline is actually the converted spline by poles. Because of this unexpected behavior, after such spline is converted to spline by poles, we will block the de-selection. If user wants to go back to where it was, hit UNDO will bring it back.

2189196

CPJ:child-parent relationship of a body is not displayed.

2189231

Siemens PLM believes that the problem you reported where uc1653 returns the incorrect view information following selection of an object will be resolved by code changes made to the upcoming release of our software NX 7.5.4, NX 7.5.5, NX 8.0.1, and NX 8.0.2 and NX 8.0.3.

2189267

Siemens PLM believes that the problem you reported where datum is aligning to text instead of the leader(Underline) will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189300

Siemens PLM believes that the problem you reported where the Specify Plane iten of the True Shading editor dialog was incorrectly hidden will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189312

Cavity Milling gouges the part, cuts to the bottom of the mold plate.

2189313

Siemens PLM believes that the problem you reported where a Zlevel Profile operation gouged the part will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189328

Cannot change the leader position of Tabular Note Section.

2189329

Siemens PLM believes that the problem you reported where a Face Milling operation gouges a neighboring wall will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 94: NX_Errors - 8.5

2189334

Siemens PLM believes that the problem you reported where the Open C function UF_DRF_set_associativity_data() acts different with newer parts will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189359

The problem where the Step Face function of Move face is not covered in the documentation, has been investigated. The new Step Face option for the Move Face command was documented in the NX 8.0.1 release in the What's New Guide, in the topic "Move Face - Step Face enhancement." Although this topic was technically correct, it was not obvious from the image that the top surface on which the Step Face option was employed consisted of two separate faces and not one. The text mentioned faces that were "neighboring" and coplanar, and in the image the two faces were colored differently. However, when users tried this themselves with a mockup part they tended to forget that the top surface was two faces and not one. This has been corrected in the NX 8.5 What's New Guide, which now includes the statement: "In this example the top face has been split into two faces." The NX 8.5 What's New Guide also uses a better model for the example figure. Full help documentation for the Step Face option is provided in the NX 8.5 Help.

2189380

Siemens PLM believes that the problem you reported where the "Browse" option is unreadable in Japanese in the Machining Knowledge Editor on the "NX Configuration Files" dialog when opening the "machining_knowledge.xml" file will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189387

Siemens PLM believes that the problem you reported where the version information display of the MKE is unreadable will be resolved by code changes made to the upcoming release of our software is fixed in NX 8.5.

2189428

Siemens PLM believes that the problem you reported where nodes cannot be selected in an assembly mesh will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189523

Import CGM changing annotation preference lettering type for color and width.

2189533

Siemens PLM believes that the problem you reported where the legacy NX Open C API function UF_MOTION_trace found more steps than were reported using the function UF_MOTION_step_articulation, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189534

Siemens PLM believes that the problem you reported where the warning "Tilt Angle is not valid" is produced when the value of the "Tilt Angle" is set to the same value as the "Maximum Tilt Angle" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189540

Siemens PLM believes that the problem you reported where the information for an arc was different between an NX Open API and interactive NX, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189558

Siemens PLM believes that the problem you reported where the bolt connection function incorrectly displays the message "radius smaller than hole radius" will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

2189561

Siemens PLM believes that the problem you reported where the pole of a curve doesn't move, when a curve is moved by the X-Form will be resolved by code changes made to the upcoming release of our software NX 8.5. When dynamic update is on, a child should not be selected in XForm, so editing spline 3 will update spline 4 automatically. Thus the selection of

Page 95: NX_Errors - 8.5

children feature in XForm dynamic update is blocked in NX 8.5.

2189564

Siemens PLM believes that the problem you reported where Convert to linked body on Promote cause source file to become modified status will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189580

Siemens PLM believes that the problem you reported where de-selecting a sketch curve had an unexpected result will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189647

Siemens PLM believes that the problem you reported where the documentation for the deprecated NXOpen > SketchCollection > CreateSketchInPlaceBuilder method failed to state what the replacement method was, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

2189680

Siemens PLM believes that the problem you reported where it was not possible to reflect the settings of Font Width in Cell Style, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189781

Siemens PLM believes that the problem you reported where an option in the Import CSV File dialog box was not documented will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189805

Siemens PLM believes that the problem you reported where an incorrect message is displayed when using 'Trimmed Sheet' will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189832

Siemens PLM believes that the problem you reported where NX to JT translations using a specific tess*.config file to produce no B-Rep in the resulting .jt file does not work, will be resolved by changes made to the upcoming release of our software NX 8.5.

2189892

Siemens PLM believes that the problem you reported where an internal error occurs when a filename's full-qualified path exceeds 253 characters will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189916

Invalid parameter specified for edit error when creating PMI dimension.

2189922

Siemens PLM believes that the problem you reported where the user can't use add view from part using non-master drawing as view, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189985

Siemens PLM believes that the problem you reported where the project spline is different if use the 'Project to Nearest Point on Vector' will be resolved by code changes made to the upcoming release of our software NX 8.5.

2189989

Siemens PLM believes that the problem you reported where "Save As" to New Item did not have the correct Item Name when two Items were in session, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190010

Siemens PLM believes that the problem you reported where the center point of a detail view and the placement of a detail view are not properly established if the parent view has been created using certain methods will be resolved by code changes made to NX 8.5.

Page 96: NX_Errors - 8.5

2190022

Siemens PLM believes that the problem you reported where the warning message did not make sense when exporting a JT from a Part Family Member will be resolved by code changes made to the upcoming release of our software NX 8.5 and NX 8.0.3.

2190027

Siemens PLM believes that the problem you reported where Conflicting constraints were created when the user does a Make Corner operation using zero-dimension offset curve, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190139

Siemens PLM believes that the problem you reported where the continuity is lost when you edit a curve will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190201

Siemens PLM believes that the problem you reported where it was not clear in the NXOpen documentation that animation methods were only available for internal programs will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190210

Siemens PLM believes that the problem you reported where The Japanese translation of the message displayed by "Import Part" is wrong, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190223

Siemens PLM believes that the problem you reported where custom symbols created in NX 5 are showing a loss of associativity when edited in NX 7.5 because of the use of "Edit Associativity" in NX 5 will be resolved by code changes made to NX 8.5.

2190337

Siemens PLM believes that the problem you reported where the Japanese folder name for Home is garbled will be resolved by code changes made to the upcoming release of our software NX 8.5 with TC9.

2190375

Siemens PLM believes that the problem you reported where Develop Trim Line caused unexpected spikes in the output spline, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190377

Siemens PLM believes that the problem you reported where the deformation plots were different between param,post,-1 and param,post,-2 will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190380

Siemens PLM believes that the problem you reported where the legacy NX Open C API function UF_DISP_refresh (and its wrapper method NXOpen.UF > UFDisp > Refresh) did not remove temporary dimensions created using Analysis -> Measure Distance... or Measure Angle... from the display, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190450

Siemens PLM believes that the problem you reported where object type-masking for selection in the Block Styler did not work as expected will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190502

Siemens PLM believes that the problem you reported where Feature Update caused a face color to change, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190685

Siemens PLM believes that the problem you reported where the Stone Impingement tool failed when the number of Analysis Faces was less than the number of Blocking Faces will be resolved by code changes made to the upcoming release of our software NX 8.5.

21906 Siemens PLM believes that the problem you reported where frequent errors are returned when

Page 97: NX_Errors - 8.5

90 editing a model will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190699

Cannot get OrdinateOriginDimension of an OrdinateDimension or vice versa.

2190700

Siemens PLM believes that the problem you reported where an Internal Error was returned when generating a Centerline Drill operation with no tool will be resolved by code changes made to the upcoming release of our software in NX 8.5.

2190701

Siemens PLM believes that the problem you reported where the NX Open API did not provide methods to obtain the OridinateOriginDimension of an OrdinateDimension, and vice versa, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190730

Siemens PLM believes that the problem you reported where the NXOpen API method NXOpen.Annotations > Annotation > InsertIntoStack did not work as expected when using the NXOpen.Annotations > StackAlignmentPosition > Above, will be resolved by documentation changes made to the upcoming release of our software NX 8.5. The documentation has been updated to explain the designed behaviour of stacking. When annotations are in a stack, the top most annotation is the owner of the stack. These are the examples given in the PR:  

Scenario 1: The user stacks annotation A to annotation B with the stack alignment set to Below Result: A moves below B because B is the top annotation in the stack and thus the stack owner.  

Scenario 2: The user stacks annotation A to annotation B with the stack alignment set to Above Result: B moves below A because A is the top annotation in the stack and thus the stack owner In both cases the annotation that becomes the stack owner stays stationary and the annotation that is becoming the subordinate moves to the owner. This can be seen interactively as well by dragging an annotation into a stack. If you drag the annotation into the stack and make it the top annotation then it is now the owner of the stack and moving it will move the entire stack. However, if you drag it below another annotation then it will be inserted as a subordinate to the owner and will then move when the owner moves.

2190789

Siemens PLM believes that the problem you reported where enabling the Customer Default value of "Disable Auto Z Clipping Planes Update for Fit" was not honored when starting NX will be resolved by code changes made to the upcoming release of our software NX 8.0.3. and NX 8.5.

2190791

Siemens PLM believes that the problem you reported where curve is not trimmed at precise location, when you want "Trim Curve" to two separate curves, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190813

Siemens PLM believes that the problem you reported where UF_UI_specify_vector acts differently in NX 8 than NX 7.5 will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190879

Siemens PLM believes that the problem you reported where a Drawing View Update failed reporting: "Invalid number given for record of this type", will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 98: NX_Errors - 8.5

2190882

CPJ : About the difference between ViewCollection.Refresh and UF_DISP_refresh.

2190887

Siemens PLM believes that the problem you reported where in Tool Path--> Verify the tool isn't visible anymore, if the tool display is set to ON, POINT or AXIS will be resolved by code changes made to the upcoming release of our software NX 8.5.

2190903

Siemens PLM believes that the problem you reported where selection of a section edge curve by filtering would not work will be resolved by code changes made to the upcoming release of our software NX 8.5.

2191034

Siemens PLM believes that the problem you reported where,Response Simulation cannot defined a sensor on the mid node, will be resolved by code changes made to the upcoming release of our software, NX 8.5.

2191053

Siemens PLM believes that the problem you reported where play of a journal from a toolbar button cancelled the automatic UI lock that was applied when using "File -> Execute -> NX Open", will be resolved by code changes made to the upcoming release of our software NX 8.5.

2191056

CPJ : If we used BlockDialog.DialogMode.Edit, we cannot select the object.

2191142

Siemens PLM believes that the problem you reported where the "Patch Openings" face selection is slow will be resolved by code changes made to the upcoming release of our software NX 8.5.

2191171

Siemens PLM believes that the problem you reported where there was an incorrect translation string on the 'Model Display' dialog will be resolved by code changes made to the upcoming release of our software NX 8.5.

2191181

Equivalent plastic strain of shell bottom are all zero.

2191273

Siemens PLM believes that the problem you reported where Internal of a sketch will reset only curved width will be resolved by code changes made to the upcoming release of our software NX 8.5.

2191448

Siemens PLM believes that the problem you reported where no information was provided to direct the user to a suitable replacement for a deprecated method in the ExtractFaceBuilder class will be resolved by code changes made to the upcoming release of our software NX 8.5.

2191453

Siemens PLM believes that the problem you reported where the documentation for the replacement for SetDraftAngle is missing will be resolved by code changes made to the upcoming release of our software NX 8.5. In earlier versions of NX, to set the value of the expression, modify the expression directly using GeometricUtilities.SimpleDraft.DraftAngle and Expression.RightHandSide.

2191454

Siemens PLM believes that the problem you reported where the Projection Vector option "Swarf Ruling" is not available when selecting "Swarf Drive" tool axis will be resolved by code changes made to the upcoming release of our software NX 8.5.

2191462

Siemens PLM believes that the problem you reported where the value of an Angle Measurement expression was not correct when edited in Assembly Context, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 99: NX_Errors - 8.5

2191463

Siemens PLM believes that the problem you reported where strange behavior is occurring when using the "Transition with Pyramid Elements" toggle button will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

2191465

Siemens PLM believes that the problem you reported stating that when meshes are connected by pyramid elements, mid nodes are not merged, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

2191507

Siemens PLM believes that the problem you reported where details of the new function "Manage AFEM Components" are not clear will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5. The Manage AFEM Components dialog box is documented in NX 8.5. In addition, basic concepts and procedures for model structure/AFEM synchronization are documented in the help under Home-->CAE-->Advanced Simulation-->Teamcenter Integration for Simulation-->Synchronizing Teamcenter model structures with Advanced Simulation files.

2191519

Siemens PLM believes that the problem you reported where UF_SF_ask_node_pgeoms() is wrapped incorrectly will be resolved by code changes made to the upcoming release of our software NX 8.5.

2191599

Cannot edit the line width (thin normal thick) of character in tabular note.

2191641

Siemens PLM believes that the problem you reported where Negative stock is ignored if Cut Area is used but was recognized in NX 4 will be resolved by code changes made to the upcoming release of our software in NX 8.5.

2191705

Siemens PLM believes that the problem you reported where Unexpected section curves appear when creating section view to a sheet body will be resolved by code changes made to the upcoming release of our software NX 8.5.

2191831

Siemens PLM believes that the problem you reported where an error recovery was raised when dragging a Datum Symbol, that had just been edited to add a leader, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2191913

Siemens PLM believes that the problem you reported where meshpoints disappear on a circulare edge will be resolved by code changes made to the upcoming release of our software NX 8.5.

2191920

Siemens PLM believes that the problem you reported where view mappings can go stale after an undo which might involve a significant scale change after the related undo mark was set, and where the undo is implicit (for example, as might be done by canceling a dialog) and which leads to odd behavior after, such as the inability to pick things where they appear to be or a view regeneration making the graphics area look small, will be resolved by code changes made to the upcoming release of our software NX 8.5. Prior to NX 8.5, such situations can be trivially worked around by causing a non-destructive and temporary change to the size of the graphics window which indirectly causes a re-computation of the affected mappings. For example, if one were to pin then un-pin a navigator (or un-pin then re-pin depending on your initial state), or un-maximize then re-maximize the NX session or affected graphics window (or vice-versa depending on your initial state), it will resolve the issue when it occurs. There are no plans to backport the related changes at this time due to the sensitivity of the area involved and the availability of a work around.

2191987

Siemens PLM believes that the problem you reported where Sketch constraints is not reflected after finish sketch will be resolved by code changes made to the upcoming release of our

Page 100: NX_Errors - 8.5

software NX 8.5.

2192053

Siemens PLM believes that the problem you reported where Model Compare failed to report a unique hole feature in one of the parts, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2192101

CPJ:A cut of a Custom Symbol and Note will generate an internal error.

2192114

Siemens PLM believes that the problem you reported where the text of a custom symbol gets copied multiple times in modeling after copying a custom symbol, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2192117

Siemens PLM believes that the problem you reported where the documentation did not clearly state that a direction vector used to calculate a projected distance measurement must be in the coordinate system of the work part, when the work part is not the display part, will be resolved by code changes made to the upcoming release of our software NX 8.5. In the example provided with this PR, if the code is modified slightly to get the prototype of the selected face to obtain the normal for the direction, then the direction vector provided will be in work part coordinates, and the expected distance result will be obtained.

2192153

Siemens PLM believes that the problem you reported where "If Polygon Body is targeted, the translucency will not operate." will be resolved by code changes made to the upcoming release of our software NX 8.5.

2192323

The specified expression variable does not exist when insert UDF.

2192325

Siemens PLM believes that the problem you reported where Model compare against edges are producing inconsistent result will be resolved by code changes made to the upcoming release of our software NX 8.5.

2192327

Unable to reference parent objects that are either suppressed or modeled away.

2192402

Siemens PLM believes that the problem you reported where Datum planes can be selected by "Minimum Clearance" of "Projected Distance" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2192461

Siemens PLM believes that the problem you reported where, "When the face is chosen to define the section, it is removed from body" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2192503

Siemens PLM believes that the problem you reported where you could not export a Sketch Curve that was added to a view of another sheet will be resolved by code changes made to the upcoming release of our software NX 8.5.

2192507

CPJ: Threaded line of instance hole feature does not display.

2192509

CPJ: "Invalid thread length" alerts display.

2192639

Siemens PLM believes that the problem you reported where SetRetainDimensions() did not behave as expected will be resolved by code changes made to the upcoming release of our

Page 101: NX_Errors - 8.5

software NX 8.5. The legacy "retain dimensions" functionality has been replaced with PMI functionality.

2192674

Siemens PLM believes that the problem you reported where the documentation did not clearly explain that SelectObject(s) should be replaced by the newer SelectTaggedObjects(s) in NX 8 will be resolved by code changes made to the upcoming release of our software NX 8.5.

2192753

CPJ : MeasureManager.NewDistance() provides wrong output.

2192958

Siemens PLM believes that the problem you reported where checkmate out-of-date-status check was not available will be resolved by code changes made to the upcoming release of our software NX 7.5.4 MP8 and NX 8.5.

2193029

Siemens PLM believes that the problem you reported where the legacy Add Component Customer Default: "Multiple Add" still exists, will be resolved by code changes made to the upcoming release of our software NX 8.5. This customer default has been removed.

2193034

Siemens PLM believes that the problem you reported where the information on the "File Specifications" page in the NX Essentials manual needed updating, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

2193041

Siemens PLM believes that the problem you reported where Untrim was raising error - Unable to reference face error for Untrim surface will be resolved by code changes made to the upcoming release of our product NX 8.5 Now, suitable error message is displayed for such cases - "Cannot extend face due to complex geometry of the face. Try Enlarge Surface." The reason is body from PR data is supplied for Untrim feature is having complex geometry and Untrim feature is not able create output. The work-around to extend the face is to use Enlarge surface or N-sided surface command for such complex geometries when Untrim is not able to produce expected output.

2193248

Siemens PLM believes that the problem you reported where two PMI notes in Leader "gwif", display differences of icon, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2193362

Siemens PLM believes that the problem you reported where the result of sew operation is inconsistent will be resolved by code changes made to the upcoming release of our software in NX 8.5.

2193373

Siemens PLM believes that the problem you reported where the UGII_LANG variable was case sensitive for font names, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2193375

Siemens PLM believes that the problem you reported where the "SEF" command was not being written correctly with ANSYS inp file exportation will be resolved by code changes made to the upcoming release of our software NX 8.5.

2193387

Siemens PLM believes that the problem you reported where Alert messages are displayed without linefeed in NX Japanese mode even if they are long, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2193398

Siemens PLM believes that the problem you reported where an error appears when accessing the Relations Browser will be resolved by code changes made to the upcoming release of our software NX 8.5 so that the information will be submitted to the NX 8.5 documentation. Concerning the "Can't initialize the Java Virtual Machine (JVM)" error message on Windows,

Page 102: NX_Errors - 8.5

there are reported instances where NX is not able to create the JVM properly on Windows. The root cause in these scenarios is from insufficient memory to start the JVM. In most cases of insufficient memory, Java is able to report back an error code indicating this. However in some cases, Java gives back a generic error message, which NX reports to the user as "Can't initialize the Java Virtual Machine (JVM)". In NX 8.0 and forward, if NX detects there is not enough memory for the JVM, NX gives an error message to the user and then outputs more information in the syslog. In the syslog there is a section similar to the following: The JVM could not be created due to not enough memory. The Java heap size must be contiguous and the largest contiguous block available is outputted below. Windows largest block freePlease note, this number is to be used as a suggestion for setting the heap size. It is unlikely that the full amount will be able to be utilized. If a heap size larger than what is possible is needed, users can try to use the /3GB switch or its equivalent, if available for the current operating system. Otherwise the other option is to use Remoting. Please consult the NXOpen Programmer's Guide for more information on this topic.

2193439

The problem where faces that are rendered lightweight can lose their highlighting after an operation which causes them to be redisplayed is resolved in NX 8.5.

2193443

CPJ:The position of symbol which I stacked slips off in SFS.

2193493

Siemens PLM believes that the problem you reported where ELSETs are not generated properly when exporting to Abaqus will be resolved by code changes made to the upcoming release of our software NX 8.5.

2193511

Siemens PLM believes that the problem you reported where Ignore Inner Boundaries option acts differently in Crosshatch, will be resolved by code changes made to the upcoming release of our software NX 8.5 by providing a more informative tooltip for the user. This tool tip will help to let the user know that Ignore Inner Boundaries is applicable to the current selection only.

2193563

The difference in the behavior of "Alignment Position".

2193637

Siemens PLM believes that the problem you reported that when inserting a hole an "Unable to create tool body" alert appeared when it shouldn't have will be resolved by code changes made to NX 8.5.

2193876

Siemens PLM believes that the problem you reported where "ove Face is failed" will be resolved by code changes made to the upcoming release of our software NX 8.5 IP21.

2193880

Siemens PLM believes that the problem you reported where "Offset Face is failed to update" will be resolved by code changes made to the upcoming release of our software NX 8.5IP17.

2193881

Siemens PLM believes that the problem you reported where "Delete Face is failed to update" will be resolved by code changes made to the upcoming release of our software NX 8.5ip19.

2194000

Siemens PLM believes that the problem you reported where the Block Styler documentation needed more information on using the various Treelist specific callbacks, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

2194070

Siemens PLM believes that the problem you reported where the assembly product structure was not shown correctly in TcVis, will be resolved by changes made to the upcoming release

Page 103: NX_Errors - 8.5

of our software NX 8.5.

2194111

Siemens PLM believes that the problem you reported where the methods NXOpen > RuleManager > GetReferenceText() and NXOpen.UF > FKf > AskRuleTextOfReferencingObject() both incorrectly returned the Hostpointer of the Datum CSYS when used with a Datum Axis, Datum Plane, or point component of a Datum CSYS, will be resolved by code changes made to the upcoming release of our software NX 8.5. A new method NXOpen > RuleManager > GetObjectText() has been created to return the expected Hostpointer and the documentation for the GetReferenceText mehod has been updated to explain this.

2194166

iTest: Routing Sweep is created as a separate feature when adding to Stock Fold.

2194241

Siemens PLM believes that the problem you reported where Import AutoCAD Block creates symbol with unexpected anchor point will be resolved by code changes made to the upcoming release of our software NX 8.5.

2194325

Siemens PLM believes that the problem you reported where tolerance of a shell thickness calculated from midsurface is not clearly explained will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5. The following information is added: Pairs with single face on each side is checked against 5% distance deviation check by using sample grid of points. If the deviation is less than 5% then it is considered as a constant thickness pair and thickness is assigned as a single constant value on every node. More than 5% deviation will be considered as non-uniform thickness and true thickness values are computed at every node by using raycasting along the element normal. Calculation of thickness at every node is an expensive process and it is only applied if deviation is more than 5%.

2194410

Siemens PLM believes that the problem you reported where UGII_PCB_CR5000_VERSION should not be in pcbx_ug_model.ini file as stated in Help Doc will be resolved by code changes made to the upcoming release of our software NX 8.5 PCB Exchange Online Help Doc.

2194429

Siemens PLM believes that the problem you reported where when "List Interferences" option of the Animation dialog for ADAMS solver is selected, the subsequent report contained several bogus entries will be resolved by code changes made to the upcoming release of our software NX 8.5.

2194649

Siemens PLM believes that the problem you reported where Improve docs for .Net NXOpen.Features > Feature > AlgorithmVersion was investigated. NXOpen::Features::Feature::AlgorithmVersion was meant for internal use only and not meant to be used in customer programs. This property is therefore being deprecated in NX 8.5 as a results.

2194876

Siemens PLM believes that the problem you reported where "Coplanar is failed" will be resolved by code changes made to the upcoming release of our software NX 8.5 ip20.

2194946

Siemens PLM believes that the problem you reported where long formula causes error in non-sketch environment will be resolved by code changes made to the upcoming release of our software NX 8.5.

2194979

Siemens PLM believes that the problem you reported where super-element results cannot be deleted after displaying them will be resolved by code changes made to the upcoming release

Page 104: NX_Errors - 8.5

of our software NX 8.5.

2195039

SetTaggedObjectVector runs slowly.

2195148

Siemens PLM believes that the problem you reported where you were getting an error performing a Gouge Check will be resolved by code changes made to the upcoming release of our software NX 8.5.

2195158

Siemens PLM believes that the problem you reported where the user was unable to create a line with automatic plane in select plane option, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2195206

Siemens PLM believes that the problem you reported where Text Height was not honored in Linked Sketches will be resolved by code changes made to the upcoming release of our software NX 8.5.

2195248

Finished sketch become active upon reopening part.

2195325

Siemens PLM believes that the problem you reported where GC Toolkit "dimension style" doesn't work in NX 8, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2195360

Siemens PLM believes that the problem you reported where there was no documentation on how to import an image into a table in Drafting will be resolved by code changes made to the upcoming release of our software NX 8.5. The Import overview topic was updated to describe the Image option, and a new "Import an image into a tabular note" procedure was added to the Tabular Note section of the Drafting Help.

2195442

Siemens PLM believes that the problem you reported where angle dimension to 3D centerline could not be created correctly, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2195478

Siemens PLM believes that the problem you reported where the attribute value is reflected back in Tabular Note after executing the UNDO command, will be resolved by code changes made to the upcoming release of our software NX 8.5. This does not seem to be a regression as reported in PR text. The reference PR#2150067 reported in PR text, does not seem to be resolved by Development. For NX 7.5.5, the work-around for this problem is, select the cell then RMB->Style->Fit methods and apply to reflect correct value after UNDO. It is infeasible to back-port the fix to NX 7.5.5 due to the major architecture changes done in NX 8.5.

2195519

Siemens PLM believes that the problem you reported where "Expressions" needed to be changed to "Geometry" will be resolved by code changes made to the upcoming release of our software NX 8.5 release.

2195638

Siemens PLM believes that the problem you reported where,representation of the icon is wrong.Is misleading to the user, will be resolved by code changes made to the upcoming release of our software, NX 8.5.

2195717

Siemens PLM believes that the problem you reported "where Exported PDF file size is zero kb with output text as "Text"" is fixed in NX 8.5. The problem where an extremely small character size would lead to PDF generation failing has been fixed. The text will not appear on the PDF file, but the generation of the PDF file will succeed.

Page 105: NX_Errors - 8.5

2195723

Siemens PLM believes that the problem you reported where geometries of sketch is created in other plane instead of selected sketch plane will be resolved by code changes made to the upcoming release of our product NX 8.5

2195805

Dimension style in GC_tool kit does not work in NX 8.

2195818

Siemens PLM believes that the problem you reported where "Edit object display result is incorrect if the translucency slider is adjusted"will be resolved by code changes made to the upcoming release of our software NX 8.5.

2195832

Siemens PLM believes that the problem you reported where a fixed point is created instead of an associative point will be resolved by documentation changes made to the upcoming release of our software NX 8.5. NX never allows associative Intersection Points of Virtual Intersections. Such documentation existed in early version (NX 5), but was removed by mistake in NX 7.5. In NX 8.5 the same documentation will be reinstated as below: NX allows you to specify an Intersection Point on curves that don't physically intersect (Virtual Intersection). You might want this when the intersection lies off of the end of a curve, or when curves do not lie in the same plane. NX allows this type of intersection point, however, the resulting point is not associative.

2195835

Siemens PLM believes that the problem you reported where edit of crosshatch cannot be performed when Restrict Crosshatch is Off will be resolved by code changes made to the upcoming release of our software NX 8.5.

2195902

Siemens PLM believes that the problem you reported where the documentation for UF_MODL_subtract_bodies_with_retained_options() did not explicitly state that this function does not use the modeling tolerance will be resolved by code changes made to the upcoming release of our software NX 8.5.

2195907

Siemens PLM believes that the problem you reported where SetTaggedObjectVector() executed very slowly will be resolved by code changes made to the upcoming release of our software NX 8.5.

2195913

Improve docs for .NET NXMessageBox.

2195947

Siemens PLM believes that the problem you reported where "OKAY" is greyed out on the CSYS constructor dialogue will be resolved by code changes made to the upcoming release of our software NX version 8.5. The work-around for NX 8.0.x is to change the type of the vector to Inferred and then back to the constant type.

2195963

Siemens PLM believes that the problem you reported where the Datum Plane dialog's dialog memory retention behaved inconsistently, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2195987

Siemens PLM believes that the problem you reported where the position of a Projected View from a view with a Break Line was incorrect, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2196034

The difference in the behavior of "Alignment Position".

2196060

Siemens PLM believes that the problem you reported where "Add View" appears to copy a pattern from the work view into a new view created, when in fact it is not, will be resolved by

Page 106: NX_Errors - 8.5

code changes made to NX 8.5.

2196071

Siemens PLM believes that the problem you reported where the NXOpen.CAE > NodesOnCurveBuilder could not be used to create nodes on a Point or a Curve, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2196155

Siemens PLM believes that the problem you reported where insufficient information is provided for the "Comparison Tolerance for Equal Dimensions" option is fixed in NX 8.5. The option definition is updated with a more adequate description, and information about how to apply this options is provided in the "Distribute Annotations" topic under Drafting->Drawing Automation.

2196192

Siemens PLM believes that the problem you reported where GetNewestUndoMark() does not work as documented will be resolved by code changes made to the upcoming release of our software NX 8.5.

2196235

Finished sketch become active upon switching the sheet.

2196430

Siemens PLM believes that the problem you reported where there is an incomplete sentence in "Ability to project nodes directly onto CAD geometry" documentation will be resolved by code changes made to the upcoming release of our software NX 8.5.

2196433

Siemens PLM believes that the problem you reported where edges were not rendered as expected with Virtual Intersections enabled, will be resolved by code changes made to the upcoming release of our software NX 8.5. This change has been versioned and it will be necessary to re-version the view to NX 8.5 to access the fix.

2196599

Siemens PLM believes that the problem you reported where the documentation did not clearly communicate the Coverging Speed option in Optimization will be resolved by code changes made to the upcoming release of our software NX 8.5.

2196624

When "Type:Element Edge to Element Face" is defined, error is always output.

2196691

Siemens PLM believes that the problem you reported where the incorrect message is displayed by the 'Interference' operation will be resolved by code changes made to the upcoming release of our software NX 8.5.

2197053

Siemens PLM believes that the problem you reported where Doing [Flat Pattern], a long time is taken to create it will be resolved by code changes made to the upcoming release of our software NX 8.5. The performance improvement is a version fix. User needs to create a new flat pattern in NX 8.5 to achieve performance.

2197169

Siemens PLM believes that the problem you reported where a memory access violation was returned when adding a view from part will be resolved by code changes made to the upcoming release of our software NX 8.5.

2197175

Siemens PLM believes that the problem you reported where you were not able to overwrite the NXMotion file after analysis of NXMotion will be resolved by code changes made to the upcoming release of our software NX Motion Simulation Version 8.5.

2197261

Siemens PLM believes that the problem you reported where the Principal Axis calculated by Measure Bodies is inconsistent on small objects will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 107: NX_Errors - 8.5

2197263

Siemens PLM believes that the problem you reported where the NXOpen documentation improperly indicated that FeatureGroup was an abstract class will be resolved by code changes made to the upcoming release of our software NX 8.5. The documentation will be corrected to indicate that there is no KF support for this class.

2197284

Siemens PLM believes that the problem you reported where the parts list was out-of-date will be resolved by code changes made to the upcoming release of our software NX 8.5.

2197291

Siemens PLM believes that the problem you reported where when adding multiple copies of the KF enabled UDF provided using <RMB>Add Child rule or using NXOpen > RuleManager > CreateDynamicRule some of the ug_expression child rules were missing on all but the most recently added will be resolved by code changes made to the upcoming release of our software NX 8.5. All of the ug_udfs child rules will have all five ug_expression child rules. None of them will be "shared". This behavior will match the behavior seen when adding the UDF interactively using NX Modeling.

2197331

Siemens PLM believes that the problem you reported where Editing the X-form feature displays the surface in the wireframe mode will be resolved by code changes made to the upcoming release of our software NX 8.5

2197341

Siemens PLM believes that the problem you reported where the documentation for 'UF_DRF_create_symbol_font' does not give object limit will be resolved by documentation changes made to the upcoming release of our software NX 8.5 IP 19.

2197345

Siemens PLM believes that the problem you reported where the curve cannot be selected for Curve Analysis while working with X-form will be resolved by code changes made to the upcoming release of our software NX 8.5.

2197346

 The NX 8.0 and the NX 7.5.3 is behavior differ.

2197378

Siemens PLM believes that the problem you reported where the migration of the Spreadsheet from Xess to Excel loses data will be resolved by code changes made to the upcoming release of our software NX 8.5.

2197393

Siemens PLM believes that the problem you reported where some of the documentation for the Spreadsheet functions under Home > Fundamentals > Managing data with spreadsheets > Functions was not appropriate will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

2197527

Siemens PLM believes that the problem you reported where the error: "A deleted or invalid class id was used" was raised when creating an FCF, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2197566

Siemens PLM believes that the problem you reported where Gouge Distance is missing from the listing when UGII_CAM_GC_USE_HYBRID is used will be resolved by code changes made to the upcoming release of our software NX 8.5. The problem that the gouge display is not output in the display window in case of using the Hybrid gouge check could be reconstructed. However, even if the hybrid gouge check is much more stable and reliable, it does not provide the gouge distance to the user. Therefore we removed the item from the display window.

2197684

Siemens PLM believes that the problem you reported where the Suppression of a View Break Line will display a garbled warning in the Japanese environment, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 108: NX_Errors - 8.5

2197704

Siemens PLM believes that the problem you reported where right clicking a Length Measurement feature, when a feature with an earlier timestamp was the current feature, terminated the NX session, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2197708

Siemens PLM believes that the problem where Internal error displays after "Feature playback" will be resolved by code changes made to the upcoming release of our product NX 8.5.

2197792

CPJ: Improve docs for .NET NXMessageBox.

2197794

Siemens PLM believes that the problem you reported where a JT was not created on Save, will be resolved by changes made to the upcoming release of our software NX 8.5 and NX version 8.0.3.

2197822

Siemens PLM believes that the problem you reported where an Internal Error occurs while adding an "imported I-deas symbol" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2197828

Siemens PLM believes that the problem you reported where the Topology Optimization header titles OBJ_FUNC_ID, OBJ_FUNC_DRESP and OBJ_FUNC_TERM were not clearly defined, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5. Development also provided the following information: o OBJ_FUNC_ID - identification name of the objective function given by the user. o OBJ_FUNC_DRESP - shows the name and the value of the design response used in the definition of the objective function. o OBJ_FUNC_TERM - shows the identification names and values of the terms (design responses) which are used for calculation of the value of the objective function for the specific optimization task.

2197829

Siemens PLM believes that the problem you reported where where PMI note text becomes dislocated from the note will be resolved by code changes made to the upcoming release of our software NX 8.0.3 and NX 8.5.

2197838

Siemens PLM believes that the problem you reported where manipulator position is taking from origin when it is in History free mode will be resolved by code changes made to the upcoming release of NX 8.5.

2197843

Siemens PLM believes that the problem you reported where incorrect behavior when changing parameters of the assembly constraint will be resolved by code changes made to the upcoming release of our software NX 8.5.

2197893

Siemens PLM believes that the problem you reported where when UF_MOTION_ask_solver_dof_count is used in certain conditions, NX would freeze will be resolved by code changes made to the upcoming release of our software NX Open Version 8.5.

2198024

Siemens PLM believes that the problem you reported where "Question about JT config" will be resolved by code changes made to the upcoming release of our software, NX 8.5.1.9.

2198138

Siemens PLM believes that the problem you reported where you have problems with "GetExtremeValues" method will be resolved by code changes made to the upcoming release of our software NX Open Version 8.5. GetExtremeValues is not designed to be used in results post-processing and the documentation has been updated to reflect the intended usage. The updated .Net API Reference will be published with NX 8.5, or see uf_sf.h in NX 8.0.1 for more details on the usage.

Page 109: NX_Errors - 8.5

2198226

Siemens PLM believes that the problem you reported where the style of Inherited PMI changed when updating a view, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2198228

Siemens PLM believes that the problem you reported where a Variational Sweep feature is created from tangent curves, but the G0 continuity between the resulting surfaces exceeds the 0.01 modeling tolerance will be resolved by code changes made to the upcoming release of our software NX 8.5. The Variational Sweep will need to be re-created in NX 8.5 in order to observe the fix.

2198255

Siemens PLM believes that the problem you reported where Appended Text of PMI is not displayed correctly in Drafting will be resolved by code changes made to the upcoming release of our software NX 8.5.

2198328

Siemens PLM believes that the problem you reported where Project Curve cannot be created with "invalid class id was used" error will be resolved by code changes made to the upcoming release of our software NX 8.5.

2198370

Siemens PLM believes that the problem you reported where the color of a datum coordinate system is not consistent based on the creation method used will be resolved by code changes made to NX 8.5.

2198381

Siemens PLM believes that the problem you reported where the Smooth method for interpolated tool axis vectors is not adequately described will be resolved by code changes made to the upcoming release of our software NX 8.5. In Manufacturing Milling->Surface Contouring->Variable-axis Surface Contouring->Tool Axis Added the following topic with descriptions and examples: Interpolate Vector tool axis - Smooth interpolation method.

2198394

Siemens PLM believes that the problem you reported where the sketch becomes under constrained when edited will be resolved by code changes made to the upcoming release of our software NX 8.5.

2198404

Siemens PLM believes that the problem you reported where NX may crash when closing a .sim file after running the stress wizard will be resolved by code changes made to the upcoming release of our software NX 8.5.

2198421

Siemens PLM believes that the problem you reported where a Table that contained an image could not be imported will be resolved by code changes made to the upcoming release of our software NX 8.5.

2198432

Siemens PLM believes that the problem you reported where 'SelectedIcon' does not work properly for multiple object selections will be resolved by code changes made to the upcoming release of our software NX 8.5.

2198473

Siemens PLM believes that the problem you reported where "If component to replace is closed, component is getting replaced" will be resolved by code changes made to the upcoming release of our software NX 8.5 The issue when closed part is replaced with same part is blocked by showing Message "Component to replace is same as the replacement part"

2198477

Siemens PLM believes that the problem you reported where a "Null tag not allowed" error appears when trying to place dimensions on a drawing will be resolved by code changes made to NX 8.5.

2198514

Siemens PLM believes that the problem you reported where the Follow Face option is available when Along is set to Layout, will be resolved by code changes made to the upcoming

Page 110: NX_Errors - 8.5

release of our software NX 8.5 documentation. Changed the lead sentence for Follow Face documentation to "Not available when Layout is set to Reference."

2198526

Siemens PLM believes that the problem you reported where Playback failed after creating a Trim Curve feature, will be resolved by code changes made to the upcoming release of our software NX 8.5. However, please note that to see the fix, a new Trim Curve feature will need to be created in NX 8.5.

2198541

Siemens PLM believes that the problem you reported where the 'reference point' of the ordinate dimensions exported to 2D Exchange and then converted from the .dxf file, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2198696

Siemens PLM believes that the problem you reported where the Record Macro documentation was missing some important notes, will be resolved by code changes made to the upcoming release of our software NX 8.5. The topic "Record a macro" has been updated to add information about using Gateway Reset and the limitations of a Macro Playback.

2198734

Siemens PLM believes that the problem you reported where it tries to open other part file and fails will be resolved by code changes made to the upcoming release of our software NX 8.5.

2198935

Siemens PLM believes that the problem you reported where inheriting PMI when creating a draft view raised the error: "Invalid annotation plane for annotation", will be resolved by code changes made to the upcoming release of our software NX 8.5.

2198936

Siemens PLM believes that the problem you reported where "Combined Projection" command incorrectly creates Spline from Line inputs will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199031

Siemens PLM believes that the problem you reported where the documentation for the Spreadsheet functions HLOOKUP and VLOOKUP was not available, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199066

Siemens PLM believes that the problem you reported where the Documentation of Intranet security setting for NX8 and .Net v4 was incorrect will be resolved in the upcoming release of our software NX 8.5.

2199140

Siemens PLM believes that the problem you reported where the top and bottom results range was not reflected correctly in the identify command when selected by range will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199172

Siemens PLM believes that the problem you reported where "ANNO" type of entities are not being translated to JT correctly, will be resolved by changes made to the upcoming release of our software NX 8.5.

2199181

Siemens PLM believes that the problem you reported where a Constructed Feature name is not updated to upper case inside the dialog will be resolved by code changes made to the upcoming release of our software in NX 8.5.

2199226

Siemens PLM believes that the problem you reported where uc5566() throws an internal error and terminates the NX session will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199237

The problem where components do not display correctly in Offset Section views has been investigated and the following has been found: The workaround to this issue is: 1. Use menu "Edit -> View -> Section In View"

Page 111: NX_Errors - 8.5

2. Select view SX@5 or SX@6 3. Select component "01F80M10" either from the assembly navigator or using the quick pick list. 4. Select the option "Make Sectioned" 5. Select OK. 6. Now update the corresponding view.

2199242

Siemens PLM believes that the problem you reported where a Custom Symbol could only be placed relative to the Absolute Coordinate System will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199247

Siemens PLM believes that the problem you reported where the user is unable to make a point-on-curve constraint in the given sketch, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199266

Siemens PLM believes that the problem you reported where enforced displacement rotation vectors were improperly displayed will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199267

Siemens PLM believes that the problem you reported where Simulation Results are not converted rightly by Clone command will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199359

Siemens PLM believes that the problem you reported where Offset symmetric sketch curve created with dimension, cannot be moved will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199382

Siemens PLM believes that the problem you reported where Japanese translation is not correct when creating mesh collectors will be resolved by code changes made to the upcoming release of our software NX version 8.5.

2199472

Siemens PLM believes that the problem you reported where a change of operation feedrate flags the operation as needing to be regenerated will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199551

Siemens PLM believes that the problem you reported where creating a Point Constructed Feature using an INSP_FEAT_CIRCLE produces an Internal error"will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199560

Siemens PLM believes that the problem you reported where when Japanese is put in Description, the Information window is garbled, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199562

Siemens PLM believes that the problem you reported where "Hole" is not created correctly will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199565

Siemens PLM believes that the problem you reported where an unspecific error recovery occurs with the Interpart Link Browser will be resolved by code changes made to NX 8.5.

2199618

Siemens PLM believes that the problem you reported where UF_CURVE_ask_int_curve_parents() report incorrect object Tags will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199673

Siemens PLM believes that the problem you reported where the wrappend dimple display visualization, will be resolved by code changes made to the upcoming release of our software

Page 112: NX_Errors - 8.5

NX 8.5. The wrapped dimple material display is now working correctly in NX 8.5 in the Advanced studio display mode and HQI. Please note the materials for Basic studio are simulated and may not match with Advance Studio or HQI... For example, in the case where the materials has both displacement or bump shader and pattern wood shader, the scale of the pattern shader will take precedence over bump shader. So in these case, the bump effect may disappear.

2199675

Siemens PLM believes that the problem you reported where the number of animation frames was hard-wired and not controlled by the template files will be resolved by code changes made to the upcoming release of our software NX 8.5 Stress Wizard.

2199724

Siemens PLM believes that the problem you reported where pictures in Pre-NX 6 UI Styler dialog file are not reloaded properly will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199728

Siemens PLM believes that the problem you reported where double click of "Symbolic Thread" feature was not found as a selection candidate will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199807

CSV to AFU conversion error.

2199871

Siemens PLM believes that the problem you reported where the changed quadrant in the dialog is not reflected on the hole table will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199877

Siemens PLM believes that the problem you reported where "Move Object" operation will throw error if ID Symbol and Label are moved, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199890

Siemens PLM believes that the problem you reported where the length of section line is changed when the part is loaded with Lightweight Represntaions will be resolved by code changes made to the upcoming release of our software NX 8.5. The user has to version up the section line using Preferences -> Drafting Preferences -> General command to correct the length of section line.

2199919

Siemens PLM believes that the problem you reported where the "Limits and Fits" dimensions export incorrectlywhen using Convert 2D Exchange will be resolved by code changes made to the upcoming release of our software NX 8.5.

2199984

Blend All Instances option doesn't exist in NX8 Edge Blend.

2199989

Siemens PLM believes that the problem you reported where an edge remained highlighted when the Apply callback for a block styler dialog returned a positive value will be resolved by code changes made to the upcoming release of our software NX 8.5. The expected behavior in this case is that all selected objects remain highlighted, but this may not have been clear in the documentation. The behavior demonstrated in relation to this PR where one edge was highlighted and one edge was not does not occur in NX8.0.3 or NX 8.5.

2200001

Value is not memorized in Edge Blend.

2200083

Siemens PLM believes that the problem you reported where edges were visible from the backside of the part when the part was Sectioned and Shaded and edges did not display when

Page 113: NX_Errors - 8.5

turning off View Sectioning, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200137

Siemens PLM believes that the problem you reported where using "Advanced curve fit of Intersection Curve, NX displayed error" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200343

Siemens PLM believes that the problem you reported where the option of NX Advanced Search - The hidden conditions are displayed will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200375

Siemens PLM believes that the problem you reported where the part file cannot be opened from Selection Minibar, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200382

The translation of "Back" view in Japanese environment is incorrect.

2200390

Siemens PLM believes that the problem you reported where Elements of Hidden component is displayed will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200426

Siemens PLM believes that the problem you reported "When you run the 2D Exchange,shifts the position of the leader line" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200448

Siemens PLM believes that the problem you reported where Alerts was not displayed although the face of a solid body is missing will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200510

Siemens PLM believes that the problem you reported where a portion of partlist's line width becomes thin will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200668

Siemens PLM believes that the problem you reported where detail view is still out of date after update view will be resolved by code changes made to the upcoming release of our product NX 8.5.

2200725

Siemens PLM believes that the problem you reported where Blank Selection not displayed in ISV simulation will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200806

Siemens PLM believes that the problem you reported where NX could not open an assembly whose ItemID was edited in Teamcenter, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200836

Siemens PLM believes that the problem you reported where Offset curve is not using curve direction correctly will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200850

Siemens PLM believes that the problem you reported where the FEM update failed when opening the sim file created in NX5 will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

22009 Siemens PLM believes that the problem you reported where If there are already points,

Page 114: NX_Errors - 8.5

15 selected points in the 1D connection is lost will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200942

Siemens PLM believes that the problem you reported where A part of "Section" of "Extrude" is de-selected will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200951

Siemens PLM believes that the problem you reported where Arc Length becomes zero when "Check Arc Length Range" Check-Mate test is execute will be resolved by code changes made to the upcoming release of our software NX 8.5.

2200959

Siemens PLM believes that the problem you reported where a face will be distorted if [Make Coplanar] is edited will be resolved by code changes made to the upcoming release of our software NX 8.5.

2201112

Siemens PLM believes that the problem you reported where Internal Error occurs while feature is made Current Feature will be resolved by code changes made to the upcoming release of our software NX 8.5.

2201113

Siemens PLM believes that the problem you reported "when reset button is pushed, the value differs from a customer default" will be resolved by code changes made to the upcoming release of our software NX 8.5.

2201124

Siemens PLM believes that the problem you reported where an internal error occurs when undoing after an update error in the Edit->Curve->Trim command, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2201142

The value of setting group is changed to the value of the original.

2201167

Siemens PLM believes that the problem you reported where ApplicationSwitchRequest() returns Internal error: memory access violation error will be resolved by code changes made to the upcoming release of our software NX 8.5.

2201566

Siemens PLM believes that the problem you reported where performing Copy To Layer of a note creates a disjoint, but linked leader and note, will be resolved by code changes made to the upcoming release of our software NX 8.5.

2201582

Siemens PLM believes that the problem you reported where SheetSectionLines() gets Section Line Tag from wrong drawing sheet will be resolved by code changes made to the upcoming release of our software NX 8.5

2201595

Create Pattern(along curve) for instanced hole some of instances are missing.

2202015

Siemens PLM believes that the problem you reported where n NX 8.0.1 Move Face is not showing correct results like NX 7.5 will be resolved by code changes made to the upcoming release of our product NX 8.5.

2202030

Siemens PLM believes that the problem you reported where a CSYS entity associated with an operation cannot be deleted will be resolved by code changes made to the upcoming release of our software NX 8.5.

2202072

Siemens PLM believes that the problem you reported where super element op2 file greater than 2GB was not able to load in Assembly FEM will be resolved by code changes made to

Page 115: NX_Errors - 8.5

the upcoming release of our software NX 8.5.

2202361

Siemens PLM believes that the problem you reported where Getting error after opening part and unable to access the part navigator will be resolved by code changes made to the upcoming release of our software NX 8.5.

2202605

Siemens PLM believes that the problem you reported where Unable to open part file in NX 8. NX Fetch "Internal error" will be resolved by code changes made to the upcoming release of our product NX 8.5 and NX 9.

2202638

IPW is incorrect switching between turning and drilling.

2202674

Siemens PLM believes that the problem you reported where a formula of impact force in the help document is incorrect will be resolved by code changes made to the upcoming release of our software NX Motion Simulation Version 8.5.

2202699

Siemens PLM believes that the problem you reported where the display of a bearing load may not be oriented correctly in an assembly FEM will be resolved by the code changes made to the upcoming release of our software NX 8.5.

2203554

Query on Bitmap Display in Mold Wizard Standard Part Library.

2203778

Siemens PLM believes that the problem you reported where Control character setting of datum feature symbol letter is removed by edit will be resolved by code changes made to the upcoming release of our software NX 8.5.1.

2203986

Cannot approximate offset curve for the given parameters.

2204293

Siemens PLM believes that the problem you reported where Ordinate dimensions cannot be inherited to the drawing will be resolved by code changes made to the upcoming release of our software NX 8.5.

2204545

Not able to export PMI Feature Control Frame text.

2205572

NX crashes on opening part file.

4035696

Siemens PLM believes that the problem you reported where a valid solid could not be Hollowed, will be resolved by code changes made to the upcoming release of our software NX 8.5.

4357477

Siemens PLM believes that the problem you reported where generating a face milling operation produces in a Parasolid ifail error will be resolved by code changes made to the upcoming release of our software in NX 8.5.

4602147

Wrapped tiff image appears as black.

4788065

Siemens PLM believes that the problem you reported where 'PS25.01.034 fix: Unite of two solids one side disappears' will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 116: NX_Errors - 8.5

5030062

Siemens PLM believes that the problem you reported where an error was printed in the syslog when using a multi-line text object in combination with a scrolled window in a UIStyler dialog, will be resolved by code changes made to the upcoming release of our software NX 8.5.

5074439

The problem where the customer default directory for user tools does not work correctly is fixed in release 8.5.

5087660

Siemens PLM believes that the problem you reported where the tool gouges part geometry on an engage move will be resolved by code changes made to the upcoming release of our software NX 8.5.

5168756

The problem where empty jt data sets were created for sub parts is fixed in release NX 8.5.

5183135

Siemens PLM believes that the problem you reported where the uf_plist chapter of the Open C reference Guide referred to example programs that did not exist will be resolved by code changes made to the upcoming release of our software NX 8.5.

5193713

Creation of Spun Outline result in bad geometry.

5327455

Sandvik - Spun Outline Fails for part D253_1083.

5327464

Sandvik - Spun Outline Fails for part D106_1263.

5329656

Siemens PLM believes that the problem you reported where blank overhang percentage is not honored in a Face Milling operation will be resolved by code changes made to the upcoming release of our software in NX 8.5.

5333873

Siemens PLM believes that the problem you reported where memory was not freed having applied values or created members in a part family template, will be resolved by code changes made to the upcoming release of our software NX 8.5.

5351200

Siemens PLM believes that the problem you reported where the plot layout was not accurately reflected will be resolved by code changes made to the upcoming release of our product NX 8.5.

5366405

Siemens PLM believes that the problem you reported where the Open C API function UF_MODL_trace_a_ray failed to find one of the intersection points between the line and the solid in the part provided, will be resolved by code changes made to the upcoming release of our software NX 8.5.

5387849

Siemens PLM believes that the problem you reported where Select Viewport in CGM viewer is ignored when plotting to CGM, will be resolved by code changes made to the upcoming release of our software NX 8.5.

5392025

Blank overhang not honored when tool stepover is set between 65 and 75 percent.

5392576

Siemens PLM believes that the problem you reported where in a Fixed Axis Surface Contouring operation specifying the Horizontal and Vertical Limits causes spikes in the toolpath will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 117: NX_Errors - 8.5

5413157

Siemens PLM believes that the problem you reported where the Open C API function UF_UI_display_url did not automatically bring out the browser pane so that the page was visible to the user, will be resolved by code changes made to the upcoming release of our software NX 8.5. A new function UF_UI_display_url_and_activate has been created for this purpose.

5439529

Siemens PLM believes that the problem you reported where the sewing of numerous sheet bodies takes much longer than expected will be resolved by code changes made to the upcoming release of our software NX 8.5. The Sewing of all these sheets does take some time, however it does successfully sew after about 30 minutes on a Dual Core Windows 7 2.53Ghz machine with 4GB of memory. This does not seem unprecedented for a large number of sheet bodies.

5517051

Siemens PLM believes that the problem you reported where attempting to customize a session, having disabled "Allow Menubar Customization" in the customer defaults, will set the session to the default "essentials" role, will be resolved by code changes made to the upcoming release of our software NX 8.5.

5517910

Problem has been fixed in NX8.5 IP15.

5523554

Siemens PLM believes that the problem you reported where Preview image. "Generating preview image" message in the status line will be resolved by code changes made to the upcoming release of our software NX 8.5.

5555559

Siemens PLM believes that the problem you reported where the out of the box Haas VF post is bad will be resolved by code changes made to the upcoming release of our software NX/PB8.5.

5614473

Siemens PLM believes that the problem you reported where the Constraint of a Sketch is not moving when the associated datum plane is moved will be resolved by code changes made to the upcoming release of our software NX 8.5.

5669480

Siemens PLM believes that the problem you reported where NX used only 2 processors maximum for faceting will be resolved by code changes made to the upcoming release of our software NX 8.5 Recent improvements with Parasolid, for NX 8.5 now uses four CPUs for faceting, if available.

5678034

Siemens PLM believes that the problem you reported where Creating part family members slows down over time for large families will be resolved by code changes made to the upcoming release of our software NX 8.5.

5687464

Siemens PLM believes that the problem you reported where the Angular dimension option should not be available when editing the Position of a Hole,.will be resolved by code changes made to the upcoming release of our software NX 8.5.

5690759

Siemens PLM believes that the problem you reported where the Open C API sample program ufd_facet_create_model caused an "Internal error" on the call to UF_FACET_model_edits_done, will be resolved by code changes made to the upcoming release of our software NX 8.5.

5693562

CAM:- Creating spun outline returns with 'Cannot derive outline from solid' .

57477 Siemens PLM believes that the problem you reported where it was not possible to reassociate

Page 118: NX_Errors - 8.5

93 a Retained Cylindrical Dimension back to its original face, unless the view bounds were edited to show the entire body, will be resolved by code changes made to the upcoming release of our software NX 8.5.

5766077

Siemens PLM believes that the problem you reported where the Open C API documentation for the function UF_ABORT_ask_flag_status did not explain its limitations, will be resolved by documentation changes made to the upcoming release of our software NX 8.5. When 'OK' is pressed in the "Work In Progress" dialog, if NX has not had a chance to act on the signal, then UF_ABORT_ask_flag_status() will return TRUE. But in majority of the situations, NX will process the abort request properly, perform the house keeping, reset the ABORT signal, and exit. In these situations, UF_ABORT_ask_flag_status() will return FALSE.

5792013

Customer receives syntax errors running NX5_template_setup.bat.

5792567

Siemens PLM believes that the problem you reported where NX failed to create a face from a spun outline curve. will be resolved by code changes made to the upcoming release of our software NX 8.5.

5803598

The problem where "importing modified templates, errors running nx5_template.setup.bat" is fixed in release NX 8.5.

5812415

Siemens PLM believes that the problem you reported where the Parts List Style option Automatic Update is being turned off when a GRIP program imports a parts list using the RPATT command with the PLMODS,2 modifier, will be resolved by code changes made to the upcoming release of our software NX 8.5.

5842676

Siemens PLM believes that the problem you reported where the GetBodies method of the NXOpen.Features > Geomcopy class did not work on the Feature returned by the NXOpen class GeomcopyBuilder, will be resolved by code changes made to the upcoming release of our software NX 8.5.

5898851

Tested with Parasolid V24.0 build 187 plus tolerance fix. The problem where spun outline generation for given solid body failed with error message is fixed in release NX 8.5.

5899782

Siemens PLM believes that the problem you reported where the Mold Wizard slider bar not working properly with mouse clicks will be resolved by code changes made to the upcoming release of our software NX 8.5.

5906661

Tool incorrectly starts engage from top level when 'Use Tool Holder' is used.

5928513

Siemens PLM believes that the problem you reported where you were getting 'Part cannot be cut at any level' when cut area is specified will be resolved by code changes made to the upcoming release of our software in NX 8.5.

5946351

Siemens PLM believes that the problem you reported where the Cavity Milling toolpath in the part provided with the PR was producing toolpath at some levels with an excessive number of linear moves instead of long tool path segments will be resolved by code changes made to the upcoming release of our software NX 8.5.

5950158

Siemens PLM believes that the problem you reported where the NXOpen > SelectionIntentRule was not adequately explained in the documentation, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

Page 119: NX_Errors - 8.5

5954297

Siemens PLM believes that the problem you reported where Turning failed to create a face from a spun outline curve will be resolved by code changes made to the upcoming release of our software NX 8.5.

5958489

Siemens PLM believes that the problem you reported where it was not possible to see the Raster Image in Shape Studio with the supplied file, will be resolved by code changes made to the upcoming release of our software NX 8.5. The problem where Advanced Studio displays a black image is because the image used is too large. This caused a GPU error during Advanced Studio processing. Code has been added wherever possible to warn user about this error, such as when the large image texture is applied to a Raster Image or to a face. However, if the error occurs during display, there is no way to warn users about this. For these cases, the following warning message will be added to the NX syslog: "An error has occurred possibly due to insufficient graphics memory. As a result Advanced Studio display may not be correct."

5974285

Siemens PLM believes that the problem you reported where in a Zlevel Profile operation "Open Area" engages (Engage Type-->Arc) are being output as "Plunge" engages due to tool holder checking (Use Tool Holder) being activated will be resolved by code changes made to the upcoming release of our software NX 8.5.

5974797

Siemens PLM believes that the problem you reported where it was not possible to name a solid body with the same name as a canned view, for use in Excel with the MASS3D command, will be resolved by code changes made to the upcoming release of our software NX 8.0.3 and NX 8.5.

5988408

Siemens PLM believes that the problem you reported where a Face Milling operation does not produce a toolpath will be resolved by code changes made to the upcoming release of our software in NX 8.5.

5990910

Siemens PLM believes that the problem you reported where writing to a console created by a UF program failed after the File -> Plot operation, will be resolved by code changes made to the upcoming release of our software NX 8.5.

5994819

Siemens PLM believes that the problem you reported with Event Control Points in WEDM operation will be resolved by code changes made to the upcoming release of our software NX 8.5.

5998635

Open Area engages not being used for reposition moves caused by tool holder.

6001705

Unable to Generate Spun Workpiece.

6001707

Unable to Generate Spun Workpiece.

6005982

Siemens PLM believes that the problem you reported where the Customer defaults' lock status did not update to an imported dpv file from a previous NX version, allowing users to change the lock status, will be resolved by code changes made to the upcoming release of our software; NX 8.5.

6006060

Siemens PLM believes that the problem you reported where spun outline generation for a given solid body failed with the error message "cannot derive outline from solid" will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 120: NX_Errors - 8.5

6007612

Siemens PLM believes that the problem you reported where it is not possible to generate Part Family members when parts have Position Constraints will be resolved by code changes made to the upcoming release of our software NX 8.5.

6014263

mass3d is not working using "model" as solid name.

6035752

Full regen occurs after second undo in the sketcher.

6038176

Display is not refreshed in PNT body view.

6039333

Siemens PLM believes that the problem you reported where deleting the drawing sheet also deletes the model will be resolved by code changes made to the upcoming release of our software NX 8.5.

6040198

Siemens PLM believes that the problem you reported where you were unable to generate a spun outline from the solid body will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6040201

Siemens PLM believes that the problem you reported where you were unable to generate a spun outline from the solid body will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6040203

Siemens PLM believes that the problem you reported where NX was unable to generate a Spun Outline from the Solid will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6040204

Siemens PLM believes that the problem you reported where you were unable to generate a spun outline from the solid body will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6040206

Siemens PLM believes that the problem you reported where you were unable to generate a spun outline from the solid body will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6040208

Siemens PLM believes that the problem you reported where you were unable to generate a spun outline from the solid body will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6040211

Siemens PLM believes that the problem you reported where you were unable to generate a spun outline from the solid body will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6040214

Siemens PLM believes that the problem you reported where you were unable to generate a spun outline from the solid body will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6040215

Siemens PLM believes that the problem you reported where you were unable to generate a spun outline from the solid body will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6040221

Siemens PLM believes that the problem you reported where the user was unable to Generate the Spun Outline from a Solid will be resolved by code changes made to the upcoming release

Page 121: NX_Errors - 8.5

of our software in NX 8.5.

6044498

Siemens PLM believes that the problem you reported where a "File not found" error was raised opening a new dataset from Teamcenter when the partfile templates are not installed, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6052335

Siemens PLM believes that the problem you reported where 2D Material Removal on a grooving operation is not displayed correctly will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6056534

Siemens PLM believes that the problem you reported where Verify--> Replay with '2D Material Removal' checked on has a bad display, showing bad material for the IPW will be resolved by code changes made to the upcoming release of our software NX 8.5.

6064963

Siemens PLM believes that the problem you reported where the Point dialog's "Relative to WCS" radio button was not retained when selected, regardless of which command calls the Point dialog, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6067784

Siemens PLM believes that the problem you reported where toolbars were obscuring dialogs when the dialog was invoked when starting an application, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6075259

Siemens PLM believes that the problem you reported where the Site option menu of a custom PMI enterprise identifier did not update correctly, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6075863

File not found opening newly created dataset in NX Manager.

6084287

Hole on an angle has different shape when edited.

6085102

Siemens PLM believes that the problem you reported where the minimum clearance recognition in non-cutting moves is inconsistent will be resolved by code changes made to the upcoming release of our software NX 8.5.

6089043

Siemens PLM believes that the problem you reported where you were not getting circular engages on all passes in Zlevel Profile will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6091052

Siemens PLM believes that the problem you reported where a Solid Edge Assembly failed to open in NX, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6097702

Siemens PLM believes that the problem you reported where the documentation for the UIStyler dialog items String and Multi-line Textbox needed to explain that the Maximum Characters attribute value does not prevent the application from setting values which are longer than the maximum, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6102379

Siemens PLM believes that the problem you reported where gouge check does not work correctly will be resolved by code changes made to the upcoming release of our software in NX 8.5. A work-around for NX 7.5.5 and NX 8.0.2 is to set the ENV UGII_CAM_GC_IGNORE_STOCK=1, start NX and check for gouges. Gouge Check should

Page 122: NX_Errors - 8.5

now report the gouges.

6104408

Siemens PLM believes that the problem you reported where you were unable to generate a spun outline from the solid body will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6106736

Siemens PLM believes that the problem you reported where error messages were received when saving multi-sheet drawings containing images will be resolved by code changes made to the upcoming release of our software NX 8.5.

6108210

Siemens PLM believes that the problem you reported where attempting to create a spun outline from a solid body produces the error "Cannot derive outline from solid" will be resolved by code changes made to the upcoming release of our software NX 8.5.

6111552

Siemens PLM believes that the problem you reported where Teamcenter Precise versus Precise Working has differences between NX5 and NX6 will be resolved by code changes made to the upcoming release of our software NX 8.5.

6112121

Siemens PLM believes that the problem you reported where NX hangs when importing a Pro/E assembly, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6114331

Siemens PLM believes that the problem you reported where some fixed contour operations lose their drive point order will be resolved by code changes made to the upcoming release of our software NX 8.5.

6118202

Load Interpart Data is not working the same NX5 versus NX6 using Precise in TC.

6120775

Siemens PLM believes that the problem you reported where an Intersection Curve created a wrong curve output, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6124674

Siemens PLM believes that the problem you reported where objects that were selected with the Open C function UF_UI_select_with_class_dialog() in a callback launched from a UIStyler dialog item could not be un-highlighted after the dialog was dismissed if the second parameter ("prompt") passed to UF_UI_select_with_class_dialog() was an empty string will be resolved by code changes made to the upcoming release of our software NX 8.5.

6133706

Siemens PLM believes that the problem where two variables that were missing in plotting documentation are now added im plotting documentation and is fixed in release NX 8.5.

6135701

Siemens PLM believes that the problem you reported where texture exported to JT is not displayed correctly in TcVis, will be resolved by changes made to the upcoming release of our software NX 8.5. The problem is specific to cylindrical texture space. Problem happens when the center point and the origin point are on the same axis. To work around this problem user can pick origin point from a point on surface.

6136496

Siemens PLM believes that the problem you reported where the documentation for the NXOpen > Update > DoUpdate method did not state that an exception would be thrown when an error which causes an Undo occurred, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

Page 123: NX_Errors - 8.5

6146168

Siemens PLM believes that the problem you reported where Check-Mate's Validation Results dialog did not show the correct layer for object occurrences, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6148921

Siemens PLM believes that the problem you reported where the Feature Control Frame did not properly clean up referenced sub-objects on deletion will be resolved by code changes made to the upcoming release of our software NX 8.5.

6159282

Immediately after opening the part, "modified" appears in the title bar.

6160725

Siemens PLM believes that the problem you reported where here spun outline generation for given solid body failed with error message will be resolved by code changes made to the upcoming release of our software NX 8.5.

6172170

VAX streamline; co-linear points are not dropped as in VAX surface area drive.

6175301

Siemens PLM believes that the problem you reported where you were unable to generate a bookmark assembly file from NX, will be resolved by changes made to the upcoming release of our software NX 8.5.

6186380

'Invalid parameter specified for edit' to create dimension.

6189194

Siemens PLM believes that the problem you reported where where spun outline generation for given solid body failed will be resolved by code changes made to the upcoming release of our software NX 8.5.

6192691

Siemens PLM believes that the problem you reported where rapid prototyping does not produce a good message when it runs out of space when facetting via Parasolid will be resolved by code changes made to the upcoming release of our software NX 8.5.

6193920

Interval for Save Change Reminder is set to 60 minutes, message at 2 seconds.

6202204

Cam express not available in SE assembly.

6211886

Siemens PLM believes that the problem you reported where Hole feature goes in the wrong direction and thru multiple walls when tool intersects a blend face will be resolved by code changes made to the upcoming release of our software NX 8.5.

6213493

Siemens PLM believes that the problem you reported where correct parts list did not result on pasting parts list with locked rows will be resolved by code changes made to the upcoming release of our software NX 8.5.

6224283

VTK 7 fix Dont create section sketch.

6244192

Siemens PLM believes that the problem you reported where an NX6 Zlevel Profile operation that uses "Mixed" Cut Direction generates in NX7 with a different "Swing Angle" for the Retract motion on one side of the singe face being machined will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 124: NX_Errors - 8.5

6255780

70 meg TIF Image does not display correctly.

6264528

Siemens PLM believes that the problem you reported where Positioning Constraints are not displayed correctly on the graphics screen will be resolved by code changes made to the upcoming release of our software NX 8.5.

6264588

Siemens PLM believes that the problem you reported where additional geometry is created when doing lathe machining will be resolved by code changes made to the upcoming release of our software in release NX 8.0 and NX 8.5.

6268169

'Best fit to page' is not orienting the page correctly.

6268210

Siemens PLM believes that the problem you reported where in a Rough Turn operation using a "From Workspace" blank the IPW is incorrectly created due to the tool machining below centerline will be resolved by code changes made to the upcoming release of our software NX 8.5.

6269330

Issues after upgrading TC and NX.

6271113

SD Cut Out preview could not seen in See-Thu mode.

6272616

PVM7.0.090 fix. Can not move faces to target position at one time.

6273062

Siemens PLM believes that the problem you reported where an error was raised when deleting a deformable part, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6273970

Docs for SelectionIntentRule and derived classes need better descriptions.

6279289

UAF Testing - Part fails to update in NX 6.0.4.3 but updates with no issues in NX 5.0.4.

6279870

Siemens PLM believes that the problem you reported where a Form from an example program could not be displayed will be resolved by code changes made to the upcoming release of our software NX 8.5.

6280690

Siemens PLM believes that the problem you reported where there was an Error opening an earlier version of UGMASTER, will be resolved by code changes made to the upcoming release of our software NX 8.5 and Teamcenter 9.1.

6282397

Siemens PLM believes that the problem you reported where attempting to create a spun outline from a solid body fails will be resolved by code changes made to the upcoming release of our software NX 8.5.

6287003

NX 7.5 UAF Testing - Part fails to update in NX7.5 but updates with no issues in

6287021

NX 7.5 UAF Testing - Part fails to update in NX7.5 but updates with no issues in

Page 125: NX_Errors - 8.5

6295358

Siemens PLM believes that the problem you reported where the Knowledge Fusion documentation on the NX Annotation classes did not explain that the various annotation classes (nx_parallel_dimension, nx_angular_dimension, etc) cannot be instantiated by a custom application, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6298623

Contour area - streamline drive processor - co-linear points are not dropped.

6317504

Siemens PLM believes that the problem you reported where clarification is needed on the difference between collapsed view and expanded view will be resolved by code changes made to the upcoming release of our software NX 8.5. Siemens PLM dded clarification to the last paragraph in the topic titled "Define a force load using a spatial distribution" and also corrected and expanded the description of Collapsed and Expanded options in the Boundary Condition Display dialog box help topic. The fix will be available in NX 8.5 help.

6318707

Siemens PLM believes that the problem you reported where the Mirror function did not allow the selection of the blue axis vectors will be resolved by code changes made to the upcoming release of our software NX 8.5.

6322652

Clearance analysis is not showing values for Interference.

6327030

Siemens PLM believes that the problem you reported where generating a Cavity Milling operation results in the error "Part cannot be cut any any levels" will be resolved by code changes made to the upcoming release of our software NX 8.5.

6329920

PMI feature dimension become retained in drawing view.

6330864

Siemens PLM believes that the problem you reported where Cavity Mill is not completing a cut in the slot will be resolved by code changes made to the upcoming release of our software NX 8.5.

6333655

Siemens PLM believes that the problem you reported where a closed corner cut into an adjacent flange, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6336639

Siemens PLM believes that the problem you reported where an NX SM Mirror feature is created on the wrong side of a Bend Taper, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6337306

Siemens PLM believes that the problem you reported where a Crosshatch does not display completely will be resolved by code changes made to the upcoming release of our software NX 8.5. It is important to note that for existing crosshatches in a drawing the user will need to Version Up.

6340101

PS25.0.167 fix GM VersUp: Delete Face(25) Error: Delete failed.

6340664

Siemens PLM believes that the problem you reported where the tool path is altered when opened in NX 7.0.1 will be resolved by code changes made to the upcoming release of our software NX 8.5.

63455 Siemens PLM believes that the problem you reported where the Knowledge Fusion

Page 126: NX_Errors - 8.5

08 documentation for the "section_to_project_rules" attribute of the nx_project_curves class was insufficient, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6345541

Siemens PLM believes that the problem you reported where the Curve/Point Drive method fails to be associative will be resolved by code changes made to the upcoming release of our software NX 8.5. To make them associative, the Curve Drive geometry should be re-specified for existing parts in release NX 8.5.

6349683

Pressing the Stop button on a hung tool path generation operation does not work.

6350503

Siemens PLM believes that the problem you reported where MB2 does not OK a dialog after drawing is opened with Open C will be resolved by code changes made to the upcoming release of our software NX 8.5.

6353293

Siemens PLM believes that the problem you reported where a Pattern Face failed update after removing a body from a Subtract Boolean at an earlier timestamp, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6354602

Siemens PLM believes that the problem you reported where Editing a letter on the detail view label produces a circular reference error, will be resolved by code changes made to the upcoming release of our software NX 8.0 and later releases.

6356248

Siemens PLM believes that the problem you reported where the Knowledge Fusion documentation did not clearly explain when and how to use the values_to_cache attribute and corresponding value_to_reference method of the %nx_application class, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6356435

Siemens PLM believes that the problem you reported where bad model geometry was created after unbending a Sheet Metal part, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6370889

Editing Edge Blend from the second set is not shown correctly.

6374039

Siemens PLM believes that the problem you reported where an incorrect message was raised when a managed mode .NET dll was missing the required entry point of "Main" or "Startup" (the error message incorrectly stated what the required entry symbol name was; "ufusr" or "ufsta"), will be resolved by code changes made to the upcoming release of our software NX 8.5.

6374667

Siemens PLM believes that the problem you reported where the Block UI Styler documentation for the List Box class was insufficient, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6375344

Siemens PLM believes that the problem you reported where overwrite is not working as expected when Importing NX data into TC will be resolved by code changes made to the upcoming release of our software NX 8.5.

6376927

Siemens PLM believes that the problem you reported where Cavity Milling does not produce identical toolpath for identical cavities will be resolved by code changes made to the upcoming release of our software NX 8.5.

63785 Shift+pick (Deselect edge) does not work under the customer defaults settings.

Page 127: NX_Errors - 8.5

00

6379661

Siemens PLM believes that the problem you reported where in-path events were inserted twice will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6380511

Selected faces not remaining highlighting when adding components.

6384293

Siemens PLM believes that the problem you reported where Linear Dimensions are not working as expected after adding new features will be resolved by code changes made to the upcoming release of our software NX 8.5.

6385285

Siemens PLM believes that the problem you reported where "How to control translucency in NX tessellation" will be resolved by code changes made to the upcoming release of our software, NX 8.5.

6385811

PS22.1.254 Unexpected result using face blend.

6388452

Siemens PLM believes that the problem you reported where repeatedly changing the expression governing an Orient Angle constraint could cause it to fail to solve, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6391261

Siemens PLM believes that the problem you reported where the Hole dialog consistently took 11-15 seconds to open with the supplied part file, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6394853

Unable to load component - excluded ref set error.

6396407

Cant create Law Controlled Face Blend.

6402548

Countersunk hole on cylinder ID trim failure.

6410777

Siemens PLM believes that the problem you reported where the Check-Mate KF function mqc_askAnnotationTextProperty returned an empty list when passed a Custom Symbol object which contains text, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6412709

Siemens PLM believes that the problem you reported where adding a second sub assembly did not display in the component preview window and was added in a hidden state, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6418995

Siemens PLM believes that the problem you reported where the Drafting Transition course does not match NX Drafting selections will be resolved by documentation changes made to the upcoming release of our software CAST NX 8.5. A note has been added to the 2D self-paced drafting course that warns the user that a DraftingPlus license is needed to access and use 2D drafting functionality and menus.

6419778

Siemens PLM believes that the problem you reported where the NX Open API Programmer's Guide needed to provide more information about User Defined Object (UDO) owned objects, will be resolved by documentation changes made to the upcoming release of our software NX

Page 128: NX_Errors - 8.5

8.5.

6422504

Siemens PLM believes that the problem you reported where Cavity Mill does not cut the IPW correctly. Some levels are skipped will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6425264

Siemens PLM believes that the problem you reported where 4 axis WEDM would fail after extending edges will be resolved by code changes made to the upcoming release of our software NX 8.5.

6428345

Final Turning cut level is same as previous level.

6429423

Siemens PLM believes that the problem you reported where the Commit() method for the Step214Creator did not wait for the tranlsation to complete will be resolved by code changes made to the upcoming release of our software NX 8.5.

6430639

Run export STEP files in NXManager.

6430746

Siemens PLM believes that the problem you reported where the Close icon on the Graphics Display window closed all child part files of a displayed assembly, whether modified or not, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6431515

Siemens PLM believes that the problem you reported where editing a distance constraint that was driven by an expression showed blank field for Name and Formula in the Expressions dialog, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6431853

Siemens PLM believes that the problem you reported where there was an incorrect scaling of components in a mixed unit assembly will be resolved by changes made to the upcoming release of our software NX 8.5.

6435242

Problem having a UDO own a bsurface.

6437831

Siemens PLM believes that the problem you reported where the SignLibrary utility appeared to work when signing a library created with an incompatible toolkit will be resolved by code changes made to the upcoming release of our software NX 8.5. The signing executables have been renamed to have consistent names to help alleviate the confusion of which utility to use in NX 8.5. Additionally all the executables have been moved to the ugopen kit (as the .Net signing tool was in the ugii kit, while all the other signing tools were in the ugopen kit). The new names are "signcpp.exe" and "SignDotNet.exe".

6444017

Siemens PLM believes that the problem you reported where a MILL/TURN IPW becomes corrupt after milling operation will be resolved by code changes made to the upcoming release of our software NX 8.5. A workaround is available for NX 7.5.5 and NX 8.0 .2 by setting the ENV UGII_CAM_MILL_TURN_CONSIDER_MASTER_CONTOUR=1 and regenerating the operations.

6445950

Siemens PLM believes that the problem you reported where you received the message: "Unable to create body" when attempting to use the Sheet Metal Create Corner command on legacy data, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 129: NX_Errors - 8.5

6446352

Siemens PLM believes that the problem you reported where the documentation for the legacy Open C API function UF_MODL_ask_curve_points did not explain that it uses the units of the displayed part, rather than the units of the part containing the curve, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6447724

Calling to get a staus on PR 6202204 where CAM Express would be grayed out.

6451187

Siemens PLM believes that the problem you reported where an operation generates memory errors will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6451407

Siemens PLM believes that the problem you reported where you were not getting a .jt file created representing a deformed part, will be resolved by changes made to the upcoming release of our software NX 8.5 and NX 7.5.4-MP6.

6451705

Siemens PLM believes that the problem you reported where "NX error handling incorrect for a conflicting type display rule" will be resolved by code changes made to the upcoming release of NX 8.5.

6455581

Siemens PLM believes that the problem you reported where editing an MCS and selecting 'OK' with no changes causes the child operations to be flagged as edited will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6460173

Siemens PLM believes that the problem you reported where the license manager did not support Ipv4/Ipv6 stacks will be resolved by code changes made to the upcoming release of our software NX 8.5. The license server now properly supports IPV6.

6463785

Blend should not be distorted by the Countersunk hole.

6466450

Siemens PLM believes that the problem you reported where the list of Reference Sets did not follow any specific order when using Add Component, will be resolved by code changes made to the upcoming release of our software NX 8.5. User defined Reference Sets now appear in an alpha-numeric order.

6468763

JT file can't be created.

6473863

Siemens PLM believes that the problem you reported where using the Move Object command to create a copy of a Bounded Plane raised the message: "Unable to reference parent objects that are either suppressed or modeled away", will be resolved by code changes made to the upcoming release of our software NX 8.5.

6474394

Save as reminder has incorrect time.

6474774

Siemens PLM believes that the problem you reported where an offset face will fail examine geometry, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6479219

Assembly file closes with no opportunity to save.

64804 Siemens PLM believes that the problem you reported where CampbellCsvToAfu.vb does not

Page 130: NX_Errors - 8.5

28 work, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

6480448

Siemens PLM believes that the problem you reported where a modeler error is returned when creating a Flat Pattern will be resolved by code changes made to the upcoming release of our software NX 8.5.

6481605

Project curve cannot project a point to facet body.

6487289

Siemens PLM believes that the problem you reported where you found inconsistencies between the graphics display and the Part Navigator will be resolved by code changes made to the upcoming release of our software NX 8.5.

6492694

PS25.0.091 fix. OrientXpress surface manipulation during Move Face causes IE.

6497872

Resizing of text dont work for PMI dimension text.

6499110

Paste special command should give an appropriate massage to a user.

6506422

Siemens PLM believes that the problem you reported where selecting the font a second time in the Annotation dialog does not insert the font tags in the text window, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6508830

Siemens PLM believes that the problem you reported where in Cavity Mill, the tool holder is colliding with part geometry and not truncating the path will be resolved by code changes made to the upcoming release of our software NX 8.5.

6509625

Siemens PLM believes that the problem you reported where an Update structure operation has major performance degradation in NX 6.0.5, will be resolved by code changes made to the upcoming release of our software NX 6.0.5 Mp8, NX 7.5.5, NX 8.0.1, NX 8.5.

6514514

Siemens PLM believes that the problem you reported where the Knowledge Fusion class nx_group did not work well and was poorly documented, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6517464

Siemens PLM believes that the problem you reported where a Threaded Hole did not display the thread at a certain hole depth, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6517839

Siemens PLM believes that the problem you reported where Through Curves Mesh surface warnings were misleading, will be resolved by code changes made to the upcoming release of our software NX 8.5. Please edit the Through Curve Mesh feature, turn on and turn off Preview, and hit OK to commit the edit. This will remove the old warning flag from the feature record and no more warning messages will appear afterwards.

6521030

CAM EXPRESS is not opening model when launched from Solid Edge ST3.

6521190

Siemens PLM believes that the problem you reported where reordering independent features takes a long time, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 131: NX_Errors - 8.5

6521957

Siemens PLM believes that the problem you reported where the Non Cutting Moves vary from level to level on cylindrical geometry in a Cavity Milling operation that uses a Profile cut pattern, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6522794

Siemens PLM believes that the problem you reported where Unable to create second gusset on other side of same bend will be resolved by code changes made to the upcoming release of our software NX 8.5.

6528138

Siemens PLM believes that the problem you reported where View problem - Edges are missing in the view will be resolved by code changes made to the upcoming release of our software NX 8.5.

6531833

Color of lettering default changes after CGM import.

6531912

Siemens PLM believes that the problem you reported where the "Tool Number" column is sorted lexicographically when the column is moved will be resolved by code changes made to the upcoming release of our software NX 8.5.

6532003

Add - All Files (*.*) filter to file open dialog.

6532439

The problem where NX 7.5 Materials do not work in Teamcenter as they did in NX 5 could not be duplicated. This report indicates that the materials cannot be utilized from the physicalmateriallibrary.xml file while running in managed mode (from Teamcenter) and that every time the NX 5 file is accessed in NX 7.5 the user is prompted to update the material (even if they update the material and save the part file) cannot be duplicated. The provided files do not contain the customized phys_material.dat where the material in the provided part files comes from. Additionally, the part files provided have all been saved in NX 7.5.2. Therefore, attempts to repeat the problem without this data have been unsuccessful. While this doesn't seem to be causing the problems reported, best practices would be to not create another material library with the same name as the NX material library (physicalmateriallibrary.xml) because it makes it difficult to determine which material is being selected if both library filter toggles are enabled. It would be better to name your site library something like mycompanymateriallibraryl.xml. This would provide a visual cue to allow you to easily differentiate the materials. This is particularly true since many materials reside in both libraries. Another best practice would be to only include materials that have been modified, so that you get any updates in subsequent releases without having to update your site library as well. For instance, steel in the provided part file is at version 0.1, the site library provided is at version 1.0 and the NX material library version is 2.0.

6535032

Siemens PLM believes that the problem you reported where the CAM Express icon in Solid Edge ST3 is inactive will be resolved by code changes made to the upcoming release of our software NX 8.5. For fixes in releases NX 7.5 and NX 8.0, refer to SFB-SE-6587.

6537114

Siemens PLM believes that the problem you reported where the supplied V14 data for this PR will not open will be resolved by code changes made to the upcoming release of our software NX 8.5.

6538697

Interval for save changes reminder does not adhere to selected interval.

6539879

Siemens PLM believes that the problem you reported where the Part Navigator did not refresh when creating a KF feature with an active feature group, will be resolved by code changes

Page 132: NX_Errors - 8.5

made to the upcoming release of our software NX 8.5.

6541845

Siemens PLM believes that the problem you reported where Export 2D Exchange from displayed part that has never been saved fails will be resolved by code changes made to the upcoming release of our software NX 8.5.

6543467

Siemens PLM believes that the problem you reported where you were seeing different results for IPW collisions between 3D and 2D Dynamic will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6544119

OFFSET start limit as expression/2 is not being retained..

6548854

Siemens PLM believes that the problem you reported where Turning operations are not interpreting geometry correctly will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6549362

Siemens PLM believes that the problem you reported where a Turning Solid Groove Tool imported from the Tool Library does not rotate Tracking Points will be resolved by code changes made to the upcoming release of our software NX 8.5.

6549540

Cannot get Cam express to work w/ NX 7.5.3 & Solid Edge ST103

6551870

Siemens PLM believes that the problem you reported where users are unable to eliminate the LOAD/WIRE statement from an open profile wire EDM path will be resolved by code changes made to the upcoming release of our software NX 8.5.

6552269

NX Save Outside of Teamcenter failure scenario w/o parts.

6552691

Siemens PLM believes that the problem you reported where a Hole Mill Geometry fails to maintain settings using as template will be resolved by code changes made to the upcoming release of our software NX 8.5.

6554389

Creating a pattern feature moves solid body to current work layer.

6554503

Siemens PLM believes that the problem where NX reported "Invalid Object" opening a specification, that had a view that was added using "Add from part", if the "Precise Only" revision rule is used, will be resolved by code changes made to the upcoming release of our software NX 7.5.6, NX 8.0.2, NX 8.5 and the next available maintenance pack for NX 7.5.3.

6554519

Siemens PLM believes that the problem you reported where copying a drawing sheet that used crosshatching, duplicated features and expressions (associated to the crosshatching) in the part's history, will be resolved by code changes made to the upcoming release of our software NX 8.5. To work around this problem change the Extracted Edge style (from the View Style dialog) for all views to Associative and then create the crosshatching. When the sheet is copied and pasted, views with Associative Extracted Edges will not duplicate modeling features.

6554971

Siemens PLM believes that the problem you reported where an imported table template with expressions creates duplicate expressions, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 133: NX_Errors - 8.5

6556826

Siemens PLM believes that the problem you reported where inconsistent behavior was observed with the Pull and Offset Region commands using Label Chamfer, will be resolved by documentation changes to the upcoming release of our software NX 8.5. Pull Face and Offset Region have been added to the list of commands that support Label Chamfer in the Modeling online help.

6558085

Siemens PLM believes that the problem you reported where NX Does Not Support Custom Dataset Types is resolved by code changes made to release NX 8.5 IP13.

6559317

Siemens PLM believes that the problem you reported where you received a selection error when performing a Boolean operation will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

6559918

Siemens PLM believes that the problem you reported where the Datum Plane dialog retained the previously entered value, having defined a plane for Sectioning, and could not be reset, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6560494

Siemens PLM believes that the problem you reported where GRIP NC documentation references to &RTNFED/&RTNIMT/&DPTFED/&DPTUNT are out of date, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6560624

Siemens PLM believes that the problem you reported where displaying a UDF (User Defined Feature) opens the Class Selection dialog will be resolved by code changes made to the upcoming release of our software NX 8.5.

6560711

Siemens PLM believes that the problem you reported where Stitch command failed in certain cases will be resolved by code changes made to the upcoming release of our software NX 8.5.

6563838

"Invalid Object" warning and excluded reference warning on ref-onl sub-assembly.

6564004

Siemens PLM believes that the problem you reported where trying to perfrom a Move Component while in Manufacturing is not possible will be resolved by code changes made to the upcoming release of our software NX 8.5. The problem is that the Move Component dialog is attempting to automatically change the work part to the TOP sub-assembly in order to allow the customer to move the BLOCK component. However, it can't do that in this case as design in context is disallowed when in the manufacturing application. As demonstrated by attempting to change work part manually via Assemblies->Context Control->Set Work Part... 'Design in context is not available in this application.' The fix has been to make the Move Component dialog display the same type of message as that of the Set Work Part dialog. After the message is given the Move Component dialog is launched but with no components selected (the current selection is rejected). It is possible to change a customer default so that the Move Component dialog doesn't need to change the work part to the sub-assembly in order to move a child component of the sub-assembly. The customer default is Assemblies->Positioning->Move Component Scope, change from 'Work Part Only' to 'Anywhere in Assembly'. When this customer default is set the customer is able to move any component at any level without the need to change the work part to the parent assembly of component. The downside is that if there are many assembly constraints in the assembly there is noticeable performance hit in using this mode.

6564877

Drawing view icon grayed out after saving the drawing part.

6565856

Siemens PLM believes that the problem you reported where Not able to export assembly to xpresreview will be resolved by code changes made to the upcoming release of our software

Page 134: NX_Errors - 8.5

NX 8.5.

6566015

Siemens PLM believes that the problem you reported where text was shifted when adding a custom symbol, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6568079

Siemens PLM believes that the problem you reported where an NX Sheet Metal part file exhibited slow response if it contained pre-NX7.5 NX Sheet Metal Features will be resolved by code changes made to the upcoming release of our software NX 8.5.

6568531

Siemens PLM believes that the problem you reported where the nx502_screw_clearance_hole_standard.xml incorrectly showed reversed values for "close" and "normal" for six 1" screw clearance holes, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6569711

Siemens PLM believes that the problem you reported where you cannot create a bolt connection between sheet body and solid body will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, Version 8.5.

6570213

Flip tool around holder and reorient tool produce incorrect results.

6570421

Automation program posts interactive message.

6570989

GetVisibleExpressions - does not return String typed expressions.

6571323

GETBodies for geomcopy.

6571670

Siemens PLM believes that the problem you reported where the X and Y coordinate output is incorrect for an MTD machine that has a 4-axis C Head with a 90 degree head attached will be resolved by code changes made to the upcoming release of our software NX 8.5.

6571878

Siemens PLM believes that the problem you reported where an operation is not flagged as generated when moved to or from the Unused Items will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6572635

Siemens PLM believes that the problem you reported where an NX 7.0.1 Variable Streamline operation using Zig-Zag cut pattern generates in NX 7.5.4 with reposition moves in place of the stepover moves will be resolved by code changes made to the upcoming release of our software NX 8.5.

6572847

Siemens PLM believes that the problem you reported where generating an Area Milling operation produces a filleting error will be resolved by code changes made to the upcoming release of our software NX 8.5.

6574761

Siemens PLM believes that the problem you reported where Tool Path Based simulation fails to simulate a Drill, Deep cycle will be resolved by code changes made to the upcoming release of our software NX 8.5.

6575244

Siemens PLM believes that the problem you reported where the documentation listed for NX 7.5.3 for Post-Processing the version of ANSYS supported incorrectly as ANSYS 13 when only ANSYS 12.1 version results are supported will be resolved by code changes made to the

Page 135: NX_Errors - 8.5

upcoming release of our software NX 8.5.

6575386

Wrong error message in NX File New dialog.

6575668

Siemens PLM believes that the problem you reported where the documentation does not reflect changes in method calls will be resolved by code changes made to the upcoming release of our software NX 8.5 phase 3.

6577485

Siemens PLM believes that the problem you reported where layer options were not maintained in higher level assemblies when replacing a component, will be resolved by code changes made to the upcoming release of our software NX 8.0.3 and NX 8.5.

6577745

Siemens PLM believes that the problem you reported where the Tool Path--> Divide option is retaining the previous divide results will be resolved by code changes made to the upcoming release of our software NX 8.5.

6578651

Siemens PLM believes that the problem you reported where NX failed to load a part reporting: "An operation was attempted on an invalid or unsuitable OM", will be resolved by code changes made to the upcoming release of our software NX 8.5.

6579019

Siemens PLM believes that the problem you reported where additional documentation is needed for the storing of PAX files is fixed in release NX 8.5.

6579317

Siemens PLM believes that the problem you reported where using the CTRL Key to select objects when Postprocessing is not working as documented will be resolved by changes made to the documentation in the upcoming release of our software in NX 8.5. Customers are now instructed to use the Shift key to select the topmost object, and then select the lowermost object, before postprocessing. A note is also added to clarify that...

1. objects must be selected from the same group and in the same order as they appear in the Inspection Navigator, and

2. if you select specific program objects rather than a group, you will receive a warning that a program group will be created for the selected objects

This group is created only in the DMIS output and does not affect the program groups in the Inspection Navigator.

6579405

Siemens PLM believes that the problem you reported where Customer Defaults, Simulation, Model Preparation, Tiny Face Area and Thin Face Width should be removed will be resolved by code changes made to the upcoming release of our software NX 8.5.

6580559

Siemens PLM believes that the problem you reported where a change in the spreadsheet is not saved and you cannot create a new afu will be resolved by code changes made to the upcoming release of our software NX Motion Simulation Version 8.5.

6581388

Siemens PLM believes that the problem you reported where on Windows 7 64bit machine, exporting a file produces "File not found" system message after deleting a file from file dialog box is fixed in release NX 8.5.

6582065

Siemens PLM believes that the problem you reported where NX7.5 and NX8 fail to supply detailed information like NX 6 when a renamed file conflicts will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 136: NX_Errors - 8.5

6582079

Siemens PLM believes that the problem you reported where additional documentation is needed for the TC_NX_save_precise_on_uprev preference will be resolved by changes made to the upcoming release of our product NX 8.5.

6583395

Assembly search in NX Manager shows multiple versions.

6583806

Siemens PLM believes that the problem you reported where the values of a Screw Clearance Hole changed to their Metric equivalent after choosing Apply, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6584021

Siemens PLM believes that the problem you reported where the Documentation for the Post Builder mom_kin_5th_axis_xxx_limit commands is incorrect will be resolved by code changes made to the upcoming release of our software NX 8.5.

6584958

Shift+Ctrl+drag does not work in sketching.

6585434

Siemens PLM believes that the problem you reported where having made a component the Work Part, selecting a face in the component for a Sketch Placement Face caused the display to orient unexpectedly, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6585475

Siemens PLM believes that the problem you reported where element selection using label range takes much longer to complete.will be resolved by code changes made to the upcoming release of our software NX 7.5.5.

6585480

Siemens PLM believes that the problem you reported where British tapered threads (BSTP) did not display correctly will be resolved by code changes made to the upcoming release of our software NX 8.5.

6585956

Siemens PLM believes that the problem you reported where Post Builder double outputs Operator Messages in the Listing File will be resolved by code changes made to the upcoming release of our software NX 8.5.

6586449

Siemens PLM believes that the problem you reported where the Bundle diameter calculation algorithm chart needs to be corrected in the documentation will be resolved by code changes made to the upcoming release of our software NX 8.5.

6586640

The problem where the defunct CrystalEyes Stereo functionality was still documented in the NX product documentation has been removed in the NX 8.5 release.

6587411

Part replays on 64-bit windows, fails on 32-bit windows, NX 7.5.3.mp1.

6588352

Siemens PLM believes that the problem you reported where the Trim Angle dialog locks up when the dialog was previously cancelled will be resolved by code changes made to the upcoming release of our software NX 8.5.

6588473

Siemens PLM believes that the problem you reported where values for any NPS (straight pipe threads) tap drill size were incorrect in the nx502_Threaded_Hole_Standard.xml file, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6588609

Siemens PLM believes that the problem you reported where Datum Target becomes retained after load the file or create new will be resolved by code changes made to the upcoming

Page 137: NX_Errors - 8.5

release of our software NX 8.5.

6588676

Siemens PLM believes that the problem you reported where creating a milling tool resulted in an Internal Error will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6588699

TOOLS- cannot create milling tool getting internal error in NX 8.0 PH25.

6589414

Siemens PLM believes that the problem you reported where incorrect automatic flow curves are produced from the Cut Area of a Streamline operation will be resolved by code changes made to the upcoming release of our software NX 8.5.

6590428

Siemens PLM believes that the problem you reported where the process for sorting tools by tool number in the Operation Naviagator is not sufficiently documented will be resolved by code changes made to the upcoming release of our software NX 8.5.

6590737

DPV file works with NX 7.5.3.mp1 Drafting but does NOT work with NX 7.5.4.mp3.

6591373

Siemens PLM believes that the problem you reported where there are gouges near the large taper angle in blade machining will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6592710

Siemens PLM believes that the problem you reported where the Assembly Hidden Line function was described incorrectly in the documentation, will be resolved by code changes made to the upcoming release of our software NX 8.5. In the Assembly Hidden Line dialog box topic, the Save option now has this description: "Saves the rendered lines to a new part file with the same part units as the assembly part from which it is derived." (The paragraph mentioned in the PR was simplified in an earlier release, and is now correct as is.)

6593981

Siemens PLM believes that the problem you reported where the GRIP documentation needed to be updated in areas discussing platforms will be resolved by code changes made to the upcoming release of our software NX 8.5.

6594289

Siemens PLM believes that the problem you reported where a part failed to update after a Feature Group was created and deleted, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6594601

Siemens PLM believes that the problem you reported where NX does not find item revs after edit properties of ID, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6595464

Siemens PLM believes that the problem you reported where a tool path does not simulate correctly on a multi-axis Head/Head machine will be resolved by code changes made to the upcoming release of our software NX 8.5.

6595636

Siemens PLM believes that the problem you reported where the Command Finder still finds the Instance Feature command which has been replaced, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6595638

Siemens PLM believes that the problem you reported where the results obtained from uf5080() and UF_MODL_create_fitted_spline() were different was occurring because the modern equivalent for uf5080() is actually UF_CURVE_create_spline_thru_pts(). The error in the documentation will be resolved by code changes made to the upcoming release of our

Page 138: NX_Errors - 8.5

software NX 8.5.

6596266

Loaded CAM Express NX7.5.2 and can not open ST4 Solid Edge files.

6596403

Multi body boolean cut operation changes target body layer.

6596681

Siemens PLM believes that the problem you reported where playing back a Journal recorded with Global Deformation was requiring a different license will be resolved by code changes made to the upcoming release of our software NX 8.5.

6597106

Siemens PLM believes that the problem you reported where CAMFeature.GetFaces doesn't return the objects of Tagged Points will be resolved by code changes made to the upcoming release of our software NX 8.5.

6597324

Siemens PLM believes that the problem you reported where Tool Path Simulate does not give correct output for drilling operations that use a Lock Axis UDE to force C-axis rotation on a 5-axis B/C table/table machine will be resolved by code changes made to the upcoming release of our software NX 8.5.

6597935

Applying Body Draft is failing for 10% of cases at Daimler - two examples .

6598289

Siemens PLM believes that the problem you reported where the Block UI Styler documentation needs more information on the Properties of the Set List block, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6599288

Siemens PLM believes that the problem you reported where stacked PMI translated incorrectly to JT file, will be resolved by changes made to the upcoming release of our software NX version 8.5.

6599670

Siemens PLM believes that the problem you reported where a misleading message is output (library link will be broken) when the user edits a library tool will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6600128

Siemens PLM believes that the problem you reported where a # character in PTS Author will process as a comment will be resolved by code changes made to the upcoming release of our software NX 8.5.

6600185

Draft fails for very small angle value changes.

6600208

Shadow Curve Extract leaves gaps along tangent/silouette area .

6600593

Siemens PLM believes that the problem you reported where control the creation of trim tasks with the DOL assistant will be resolved by code changes made to the upcoming release of our software NX8.0.1 and NX 8.5. The fix will be backported to NX7.5.4 MP6 and NX8.0.1 MP2.

6600969

Siemens PLM believes that the problem you reported where a procedure is missing from the NX Help documentation that describes how to delete an ordinate set with no display name will be resolved by code changes made to the upcoming release of our software NX 8.5.

66011 Siemens PLM believes that the problem you reported where a component is missing when

Page 139: NX_Errors - 8.5

16 FEM is created out of an assembly will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, Version 8.5. An ideal part and/or fem now honors the current cad arrangement during the fem creation process.

6601227

Siemens PLM believes that the problem you reported where selecting "Analysis -> Units" to change units of a part caused a Resize Blend feature to show an incorrect Radius value, will be resolved by code changes made to the upcoming release of our software NX8.0.1 and NX 8.5.

6601745

Siemens PLM believes that the problem you reported where the 3D mesher failed to map frozen target nodes will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

6602013

Siemens PLM believes that the problem you reported where the user was getting an incorrect tool axis for a Probe Surface Point subop will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6602994

Siemens PLM believes that the problem you reported where a "circular update" error occurs when moving the component used in a Turning Setup will be resolved by code changes made to the upcoming release of our software NX 8.5.

6603106

Need updated info for &PLTFRM.

6603152

Siemens PLM believes that the problem you reported where all of the feeds are set to IPR, but some motions output as IPM could not be reproduced as there are operation data missing from the customer. Development reworked the settings of several feed units. We don´t know if this fixes the problem. If the problem still exists in NX 8.5, reopen the PR and provide more suitable customer data to development.

6603442

Siemens PLM believes that the problem you reported where a Point Set with Projecting points produced the wrong result, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6603990

Siemens PLM believes that the problem you reported where Operations with Instanced Tool Paths do not all update when selected as a group will be resolved by code changes made to the upcoming release of our software NX 8.5.

6604709

Siemens PLM believes that the problem you reported where the export procedure described in the manual is unclear will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5. This has been fixed as part of a larger documentation initiative to clarify the ways in which the NX assemblies architecture is exposed in Advanced Simulation. Export Assembly Outside Teamcenter and Import Assembly Into Teamcenter work exactly the same for CAE models as they do for any other assembly. The topics found in Home-> CAE-> Advanced Simulation-> Assemblies Concepts in Advanced Simulation make clear the assemblies nature of Advanced Simulation CAE model data. The topic Home-> CAE-> Advanced Simulation-> Teamcenter Integration for Simulation-> Importing and exporting CAE model data provides an overview of assemblies concepts specific to import/export in managed mode, and provide links to relevant topics elsewhere in Advanced Simulation as well as the Teamcenter Integration for NX online Help.

6604756

Siemens PLM believes that the problem you reported where the NX Open API Programmer's guide failed to mention how to debug on the Linux platform, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 140: NX_Errors - 8.5

6604894

DUPLICATE OF PR 6501394 with correct Customer ID.

6604898

Siemens PLM believes that the problem you reported where the Reuse Library Classification search did not have drop down menus the same as in Teamcenter, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6605295

Siemens PLM believes that the problem you reported where Create Linked Part using certain ref set fails with Missing section string will be resolved by code changes made to the upcoming release of our software NX 8.5.

6605919

Siemens PLM believes that the problem you reported where ugmanager with arguments is not opening up correctly will be resolved by code changes made to the upcoming release of our software NX 8.5.

6606078

Imported PAX file always opens in NX7.5 not the text editor.

6607083

Siemens PLM believes that the problem you reported where creating a Flat Pattern raised a Memory Access Violation, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6607647

Siemens PLM believes that the problem you reported where a facet body of an IPW is saved in a part after displaying both the previous and resulting IPWs will be resolved by code changes made to the upcoming release of our software NX 8.5.

6608213

Closing multiple parts while in manufacturing causes fatal error.

6610125

Siemens PLM believes that the problem you reported where when drawing a rectangle, "type" changes during command, will be resolved by code changes made to the upcoming release of our software NX 8 and NX 8.5.

6610177

Siemens PLM believes that the problem you reported where there was no NXOpen API wrapper method for the legacy NX Open C API function uc6442, will be resolved by code changes made to the upcoming release of our software NX 8.5. The method will be wrapped as: NXOpen.UF > UFView > ReadViewDrawingParameters.

6610298

The problem where Internal memory access error when launch NX if can't create item type is fixed in the release NX 8.5.

6610389

Siemens PLM believes that the problem you reported where Detailed Filtering on the Selection Toolbar was not recorded in a Macro, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6610434

Siemens PLM believes that the problem you reported where a drawing part file, containing shaded section views could not be saved, after executing Part Cleanup with Component Display set to "Remove All Changes", will be resolved by code changes made to the upcoming release of our software NX 8.5.

6610842

Siemens PLM believes that the problem you reported where inserting a UDF raised the message: "The specified expression variable does not exist", will be resolved by code changes made to the upcoming release of our software NX 8.5

66110 Siemens PLM believes that the problem you reported where the SPC is not imported by the

Page 141: NX_Errors - 8.5

20 File -> Append command will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5. The newly added information should help clarify that the File, Append command can only be used to import an entire deck, while the Merge Entities option allows you to import only portions of a deck.

6611229

Siemens PLM believes that the problem you reported where NX to JT translation is resulting in "_inst" for multiple part/sub-assembly usage will be resolved by code changes made to the upcoming 7.55MP2 and 8.5 releases of our NX product.

6611350

Siemens PLM believes that the problem you reported where there was a size allocation error when exporting an AFU file from NX will be resolved by code changes made to the upcoming release of our software NX 8.5.

6613243

Siemens PLM believes that the problem you reported where you reported that the Routing Specification documentation is lacking sufficient detail will be resolved by code changes made to the upcoming release of our software NX 8.5.

6614504

Siemens PLM believes that the problem you reported where the extrude form lists the element type as hex when extruding triangular shell elements will be resolved by code changes made to the upcoming release of our software NX 8.5.

6614731

Siemens PLM believes that the problem you reported where the user was recieving hypermatrix operation errors while solving response simulation will be resolved by code changes made to the upcoming release of our software NX 8.5. Changes to the file pointer system used for EEF file creation were made in NX 8.5 to allow the creation of an EEF larger than 2GB. However, the internal matrices that are created inside the EEF file are still limited in size due to the pointers involved. With the current changes, we can create larger EEF files than before with the only limit being due to the internal matrices that are added to the EEF. In general, we should be able to generate EEF files of around 3GB.

6614744

Siemens PLM believes that the problem you reported where the documentation for the method NXOpen.PDM > PdmSearch > Advanced needed to provide more information, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6615567

Siemens PLM believes that the problem you reported where a note was printed in the syslog when the targetLayer parameter of the Knowledge Fusion class ug_udfs was set to -1, indicating that the UDF should be brought in on the original layers, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6616063

Siemens PLM believes that the problem you reported where the Info Text Window does not provide rotation axis information will be resolved by code changes made to the upcoming release of our software NX version 8.5.

6616789

Siemens PLM believes that the problem you reported where a 2D mesh was being generated incorrectly will be resolved by code changes made to the upcoming release of our software NX 8.5. A work-around has been provided for versions prior to 8.5. The work-around is to use tri3 and then convert all to tri6 with element modify order. Or generate a seed mesh that is linear and tet mesh with parabolic once the seed mesh is ready.

6617712

Siemens PLM believes that the problem you reported where an error occurred when using the Knowledge Fusion class ug_edge_blend to create a variable radius blend, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6617953

Siemens PLM believes that the problem you reported where Cavity Mill ignores the part side stock will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 142: NX_Errors - 8.5

6619005

Tool Path Edit Motion Feed Rates are missing and out-of-order.

6619059

Siemens PLM believes that the problem you reported where the toolpath editor is not able to work with First Cut feedrates will be resolved by code changes made to the upcoming release of our software NX 8.5.

6620421

Siemens PLM believes that the problem you reported where an 'invalid view' error would occur if you try to modify a copy of a projected view will be resolved by code changes made to the upcoming release of our software NX 8.5.

6621625

Siemens PLM believes that the problem you reported where Linked datum plane Feature Update Failed when the parent part is suppressed will be resolved by code changes made to the upcoming release of our software NX 8.5.

6622031

Siemens PLM believes that the problem you reported where you were getting the error "Could not get preference TC_SPSD_FOLDER_PATH preference" will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

6622658

Siemens PLM believes that the problem you reported where the Milling Feeds and Speeds Spindle Speed (rpm) is undocumented will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6623280

Siemens PLM believes that the problem you reported where the Sheet Metal 'Rebend' function did not correctly locate the countersink on a hole will be resolved by code changes made to the upcoming release of our software NX 8.5.

6623374

Siemens PLM believes that the problem you reported where Gouge Checker fails to see gouges when the tool rapids through the part will be resolved by code changes made to the upcoming release of our software NX 8.5.

6623637

Siemens PLM believes that the problem you reported where shell element normals would not flip if selected by polygon face will be resolved by code changes made to the upcoming release of our software NX 8.5.

6623927

Siemens PLM believes that the problem you reported where the Check-Mate checker listing was being truncated, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6624339

Siemens PLM believes that the problem you reported where the Shape Search tool did not apply any Teamcenter Access Rules to the results before displaying them, to filter out those parts which the user is not permitted to access when NX is running in the managed environment, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6625333

Siemens PLM believes that the problem you reported where additional documentation is needed for the location of the Checkout comments after export is complete will be resolved by changes made to the upcoming release of our product NX Version 8.5.

6625881

Siemens PLM believes that the problem you reported where it is not possible to create a component drawing with NX8 MoldWizard, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6626033

Siemens PLM believes that the problem you reported where the documentation for the Block Styler was not clear will be resolved by code changes made to the upcoming release of our

Page 143: NX_Errors - 8.5

software NX 8.5.

6626925

Siemens PLM believes that the problem you reported where the Overlap Distance field on the Non Cutting Moves dialog does not accept the first typed character will be resolved by code changes made to the upcoming release of our software NX 8.5.

6627169

Siemens PLM believes that the problem you reported where the Scale command did not scale broken Linked Composite Curves, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6627915

Navigating DFS in Translators

6628304

The problem where an environment variable is used instead of the customer default is fixed in release NX 8.5.

6628706

Siemens PLM believes that the problem you reported where Motion Simulation does not start a user does not have the correct license and no error or warning message is displayed, will be resolved by code changes made to the upcoming release of our software, NX 8.5. With this release, a proper error message will be displayed.

6629246

Siemens PLM believes that the problem you reported where imported coordinate systems are being realigned to global 0,0,0 will be resolved by code changes made to the upcoming release of our software NX 8.5.

6629354

Siemens PLM believes that the problem you reported where updating a parts list raised the error "Object supplied is of the wrong type", will be resolved by code changes made to the upcoming release of our software NX 8.5. In NX 8.5, open the part and run Part Cleanup for Drafting Objects, then update the Parts List.

6630059

Siemens PLM believes that the problem you reported where it was very difficult to place a Custom Symbol drawing format at drawing origin, has been resolved by code changes made to an available release of our software NX 8.0.1 and to the upcoming release NX 8.5.

6630376

Sketch origin is moved by Merge Part Module.

6631568

Siemens PLM believes that the problem you reported where the documentation for the Check-Mate function mqc_collectDrawingMemberEdges was insufficient, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6631851

Loading Machine Tool with Structure Only set does not simulate

6631960

Going from drafting to modeling and back activates finished sketch.

6632461

Solid object display as sheet body after editing copied feature.

6632737

Siemens PLM believes that the problem you reported where Deformed part interferes with assembly constraints will be resolved by code changes made to the upcoming release of our software NX 8.5.

66334 Siemens PLM believes that the problem you reported where there was insufficient information

Page 144: NX_Errors - 8.5

99 in the error message on a WEDM tool path failure and the documentation did not adequately guide the user to a successful result will be resolved by code changes made to the upcoming release of our software NX 8.5.

6633736

Save reminder comes up at the wrong interval.

6635148

Siemens PLM believes that the problem you reported where in CSE, using a G65 macro call with an "M" argument will interperet the M as M00 and stops simulation will be resolved by code changes made to the upcoming release of our software NX 8.5.

6636169

Siemens PLM believes that the problem you reported where deforming a spring in an assembly raised the error: "Input curve not tangent continuous", will be resolved by code changes made to the upcoming release of our software NX 8.5.

6637478

Siemens PLM believes that the problem you reported where there was no definition for the meaning of "Equal Radius (Far)" will be resolved by documentation changes made to the upcoming release of our software NX 8.5. The following paragraph has been added to the help to the Move Face dialog box topic, in the Face Finder section: "To reduce the number of suggested faces, Face Finder may divide them into groups of near or far. Suggested faces that are relatively far from the selected face have (Far) appended to them." The same paragraph has been added to the same location in the help for the following Synchronous Modeling commands: Angular Dimension, Linear Dimension, Radial Dimension, Make Coplanar, Group Face, Make Coaxial, Make Parallel, Make Perpendicular, Make Symmetric, Make Tangent, Make Fixed, Copy Face, Cut Face, Mirror Face, Resize Face and Offset Region.

6638084

Siemens PLM believes that the problem you reported where the PTYPE field on the DRESP1 card is exported as blank when the "Design Response Quantities" modeling object is referencing a PSOLID physical property will be resolved by code changes made to the upcoming release of our software NX 8.5.

6638821

Siemens PLM believes that the problem you reported where geometry disappears when using the Die Trim Line feature will be resolved by code changes made to the upcoming release of our software NX 8.5.

6638982

Siemens PLM believes that the problem you reported where it takes an excessive amount of time to open an Assembly Fem, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5. Development indicated the following: This problem was due to a beam cross section with very different dimensional properties (eg: a 0.001 X 4 mm cross section). Processing of cross section properties is handled more efficiently now.

6640108

Siemens PLM believes that the problem you reported where modifying a vertical constraint raised the warning: "Feature Has Created Surfaces Which Cannot Be Flattened", will be resolved by code changes made to the upcoming release of our software NX 8.5.

6640146

Save precise doesn't work on a reference-only component .

6640420

Siemens PLM believes that the problem you reported where a Metric HeliCoil fails to work, yet inch works in nx502_Threaded_Hole_Standard will be resolved by code changes made to the upcoming release of our software NX 8.5.

6640455

Siemens PLM believes that the problem you reported where a Knowledge Fusion List with an Integer as its first member and a Number as its last member was incorrectly mapped to

Page 145: NX_Errors - 8.5

double[] rather than Object[] when passed to NX Open using nx_ja_session_execute, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6642964

Siemens PLM believes that the problem you reported where the Shank portion of the tool is not visible in Replay but the Tool and Holder are will be resolved by code changes made to the upcoming release of our software NX 8.5.

6642982

Siemens PLM believes that the problem you reported where the NX Open C API function UF_CURVE_create_offset_object ignored the specified axis_vector when using the offset_type of UF_CURVE_OFFSET_3D_AXIAL, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6644371

Siemens PLM believes that the problem you reported where the Stock value is not being adhered to so Gouge Check is detecting gouges will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6645497

Siemens PLM believes that the problem you reported where Memory Access Errors are reported when opening an ST4 NX8 CAM Express file will be resolved by code changes made to the upcoming release of our software NX 8.5.

6646471

Siemens PLM believes that the problem you reported where creating a Detail View from a Section View creates the view outside the drawing sheet boundary, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6646756

Siemens PLM believes that the problem you reported where references to parts that have been replaced in an assembly structure were retained will be resolved by code changes made to the upcoming release of our software NX 8.5.

6647020

Siemens PLM believes that the problem you reported where the Documentation for "Show Material by Thickness" does not state that this option is only for milling operations will be resolved by code changes made to the upcoming release of our software NX 8.5.

6647960

Siemens PLM believes that the problem you reported where update failures occured when members of feature group are changed, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6648701

Siemens PLM believes that the problem you reported where it was not possible to execute an NX booklet via the API will be resolved by code changes made to the upcoming release of our software NX 8.5.

6648702

Siemens PLM believes that the problem you reported where if you select multiple bodies for the "Part" geometry in the Turning module, and the bodies do not touch, two closed shape outlines are produced but only a single spun outline is produced for one of the bodies will be resolved by code changes made to the upcoming release of our software NX 8.5. The documentation has been updated to include the following information for creating curves from solids: "When using multiple bodies to create a single spun outline, the bodies must touch. You can define each body as separate sets." This information is located under the following link: 'Manufacturing -> Manufacturing Turning -> Boundary geometry -> Create Curves from Solids'.

6649928

Siemens PLM believes that the problem you reported where Feature Based Machining rules do not set engage and retract feed rates properly will be resolved by code changes made to the upcoming release of our software NX 8.5.

6650083

Siemens PLM believes that the problem you reported where opening a harness file failed raising an internal error, will be resolved by code changes made to the upcoming release of

Page 146: NX_Errors - 8.5

our software NX 8.5.

6650107

Siemens PLM believes that the problem you reported where the documentation incorrectly stated that the version portion of an object's handle is used when locating the object, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6650594

Siemens PLM believes that the problem you reported where a part cannot be saved after deleting a Generic Motion operation will be resolved by code changes made to the upcoming release of our software NX 8.5.

6650845

Getting 'Attempt to free already free memory in Storage Manager' when generating.

6650925

Siemens PLM believes that the problem you reported where assigning the REFERENCE_ID Characteristic to Stock Components, in order to identify them in the Run Navigator, resulted in a Design Rule Violation saying there were duplicate REFERENCE_ID characteristics, even when the stock is the only component, will be resolved by code changes made to the upcoming release of our software NX 8.0.2 and NX 8.5.

6650977

Siemens PLM believes that the problem you reported where File->Open and simple search returns no results, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6651016

Setting Reference only on component results in Invalid object.

6651538

Siemens PLM believes that the problem you reported where the Background Color for Assembly Sequencing does not change to Studio, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6651688

Siemens PLM believes that the problem you reported where an incorrect circular reference is reported will be resolved by code changes made to the upcoming release of our software NX 8.5. Here are the required steps for converting the legacy measurement feature in this PR to the new NX 8.5 measurement feature: 1) Open part by following the steps described in the PR text. 2) MB3 on Distance Measurement(4) in PNT, select Edit Parameters to invoke the edit dialog.3) In the edit dialog, click the OK button without doing anything else. This will complete the measure feature conversion, and the circular dependency problem will be gone.

6652207

Siemens PLM believes that the problem you reported where selecting the 'F1' key to access the Docs generates an error will be resolved by code changes made to the upcoming release of our software NX 8.5.

6653102

Siemens PLM believes that the problem you reported where an incorrect timestamp alert was raised in the Part Navigator for a Feature Group, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6653173

Siemens PLM believes that the problem you reported where the documentation did not explain that the ug_clone switch "-encrypt" was internal, will be resolved by documentation changes made to the upcoming release of our software NX 8.5. It should be noted that "-encrypt" is for use by Siemens applications only.

Page 147: NX_Errors - 8.5

6653924

Siemens PLM believes that the problem you reported where a graphic tool model and a "solid" insert are not mapping into the correct orientation will be resolved by code changes made to the upcoming release of our software NX 8.0.3 and NX 8.5.

6653947

Siemens PLM believes that the problem you reported where opening the supplied harness raised the error: "Update/Delete has gone through too many iterations", will be resolved by code changes made to the upcoming release of our software NX7.5.4 mp2 customer patch, NX 8.0.2 and NX 8.5.

6653995

Siemens PLM believes that the problem you reported where the file selection dialog displayed when using the Browse button from "Tools -> Journal -> Play" did not default to the folder specified using the environment variable UGII_INITIAL_JOURNAL_DIR, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6654008

Siemens PLM believes that the problem you reported where in ISV, the ipw disappears when Analyze is selected will be resolved by code changes made to the upcoming release of our software NX 8.5.

6655097

Siemens PLM believes that the problem you reported where an NX IDEAS XPK imported model displays Signal 11 when generating will be resolved by code changes made to the upcoming release of our software NX8.0.2 and NX 8.5.

6655147

Siemens PLM believes that the problem you reported where the Cavity Milling operation provided in the PR part failed to machine one of the slots completely will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6655402

Siemens PLM believes that the problem you reported where an error occurs when importing a Nastran file and using an include statement and customized toolbar will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

6655901

Siemens PLM believes that the problem you reported where a signal 11 is reported when using Post Results Manipulation will be resolved by code changes made to the upcoming release of our software NX 8.5.

6656000

Siemens PLM believes that the problem you reported where a Bend Taper failed when the outside radius was selected, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6656456

Siemens PLM believes that the problem you reported where a file failed to open in drafting and caused the NX session to crash, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6658290

Siemens PLM believes that the problem you reported where Incorrect documentation for Owner option in the Log File Syntax will be resolved by code changes made to the upcoming release of our software NX 8.5.

6658417

Siemens PLM believes that the problem you reported where a length vector of zero is reported when attempting to open an operation will be resolved by code changes made to the upcoming release of our software NX 8.5.

6659025

Siemens PLM believes that the problem you reported where using "Update Local IPW from Source" for the new IPW Flow process in NX 8 returns the alert "The part file containing the source for the IPW cannot be loaded" and the requirements to avoid this condition are not documented will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 148: NX_Errors - 8.5

6659187

Siemens PLM believes that the problem you reported where results from a previous solution could be displayed after renaming a solution will be resolved by code changes made to the upcoming release of our software NX 8.5.

6659680

Siemens PLM believes that the problem you reported where the NXOpen documentation did not explain why the 1dMesh required a point to be specified will be resolved by code changes made to the upcoming release of our software NX 8.5 Although the current NXOpen Documentation does not discuss this, the NX Advanced Simulation documentation does. The point indicates the starting end of the curve or edge to be meshed. Nodes or elements will start at the end closest to the point. The indicated start end is remembered by the mesh recipe for consistent re-meshes. This information appears in the NX 8 documentation under: Advanced Simulation Help Meshing, 1D Meshing, Ensuring the consistent orientation of 1D elements.

6659826

Siemens PLM believes that the problem you reported where documentation for "Transferring an IPW across multiple setups" does not state that this functionality only works in a setup assembly context will be resolved by code changes made to the upcoming release of our software NX 8.5.

6660743

NX 8.0.1.5 Drafting Update Issue.

6660898

PROBING - tool axis is incorrect should be Z axis.

6661325

Draft with new Tangent Faces option giving face with internal discontinuits.

6661599

Siemens PLM believes that the problem you reported where not all of the originally selected curves were projected to a sheet body, using the Project Curves command, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6661656

Siemens PLM believes that the problem you reported where multiple loads / attachment modes gives invalid results in a response simulation quasi-static event will be resolved by code changes made to the upcoming release of our software NX 8.5.

6662144

Siemens PLM believes that the problem you reported where user was ending up with the same ids for the hole table, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6662299

Siemens PLM believes that the problem you reported where JT translations with mixed units and assembly level sections cuts did not produce the correct JT file, will be resolved by changes made to the upcoming release of our software NX v8.5.

6663113

Siemens PLM believes that the problem you reported where the option to only have selected meshes with element outlines displayed was no longer available in NX8.0.1 but was available in NX8.0 will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

6663203

FEM fails to load in NX8.0.1 with simulation from previous version inTC.

6663530

Global shaping a Solid Body creates a Sheet Body...

Page 149: NX_Errors - 8.5

6663822

Siemens PLM believes that the problem you reported where *DSLOAD is only imported with the first surface data entry when it has multiple data entry lines will be resolved by code changes made to the upcoming release of our software NX 8.5.

6663834

Siemens PLM believes that the problem you reported where importing an Abaqus input file does not import loads properly will be resolved by code changes made to the upcoming release of our software NX 8.5.

6663900

Siemens PLM believes that the problem you reported where the Erroneous handling of the SURFACE command during Abauqs deck import that includes *DSLOAD, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

6665166

Siemens PLM believes that the problem you reported where the tool axis is output incorrectly for a Probe Surface Point suboperation will be resolved by code changes made to the upcoming release of our software NX 8.5.

6665283

Siemens PLM believes that the problem you reported where CSE does not properly handle Renishaw probe cycles for a Fanuc control will be resolved by code changes made to the upcoming release of our software NX 8.5.

6665550

Siemens PLM believes that the problem you reported where saving a part containing a deformable feature raised the error: "MOM_TCL: Interpreter returned error when doing event", will be resolved by code changes made to the upcoming release of our software NX 8.5.

6665579

Siemens PLM believes that the problem you reported where it was not possible to edit the Parameters of a Section Surface, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6666281

Creating a Feature Group to house all features makes features fail.

6666286

Siemens PLM believes that the problem you reported where the Feature Browser displayed incorrect relationships for inactive features, created with Body Selection Intent rules on a Boolean feature which was later deleted, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6666296

Siemens PLM believes that the problem you reported where the Block UI Styler did not explain the use of attachements, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6666342

Siemens PLM believes that the problem you reported where the Feature Teach routine reports that a coordinate system is missing when creating will be resolved by code changes made to the upcoming release of our software NX 8.5.

6666441

Siemens PLM believes that the problem you reported where Curvature Combs did not update while editing a spline in NX7.5, will be resolved by code changes made to the upcoming release of our software NX 8.5 and NX9.0.

6666814

Siemens PLM believes that the problem you reported where the Weld Assistant will not import a CSV file as expected if the numbering is the same with the addition of the prefix will be resolved by code changes made to the upcoming release of our software NX 8.5.

6667113

Siemens PLM believes that the problem you reported where NX fails to generate a "part safe" spun outline - Auto or 720 planes will be resolved by code changes made to the upcoming

Page 150: NX_Errors - 8.5

release of our software NX 8.5. For the given part the compulsive body check fails. That failure can be overruled in NX 8.5. Automatic spun outline creation does work for the given part although body check might fail.

6667575

Siemens PLM believes that the problem you reported where Wire Control Status options are not working and LOAD/WIRE and UNLOAD/WIRE are always output will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6667592

Siemens PLM believes that the problem you reported where a Law Extension with the Asymmetric option failed when the Offset value was edited, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6667707

turning; cut region changes from NX 7 to NX 7.5.

6669353

Siemens PLM believes that the problem you reported where show thickness by color does not work correctly will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6669544

Siemens PLM believes that the problem you reported where Transfomation Matrix in Structure Manager will be resolved by code changes made to the upcoming release of our software NX 8.5.

6670198

Siemens PLM believes that the problem you reported where Save or Save As raised the error: "The following parts failed to save causing the overall save operation to fail: While saving 12650196/001: 12650196/001 - Error number: 100043035", will be resolved by code changes made to the upcoming release of our software NX 8.5.

6671449

Siemens PLM believes that the problem you reported where the turning spun outline generates with many small lines in the given part will be resolved by code changes made to the upcoming release of our software NX 8.5.

6671491

Siemens PLM believes that the problem you reported where the Symbolic Thread display of an inch NPT thread in a metric drawing was incorrect when using Thread Type: ANSI Simplified, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6671905

Siemens PLM believes that the problem you reported where a Feature Group incorrectly raised a timestamp warning, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6672370

Siemens PLM believes that the problem you reported where NX File New dialog not come up if one pax file has missing named reference will be resolved by code changes made to the upcoming release of our software NX 8.5.

6672673

Siemens PLM believes that the problem you reported where you cannot use 3D laminate component in AFEM will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5 and also back ported to version 8.0.3.

6673946

Siemens PLM believes that the problem you reported where an error was returned when attempting to display a PMI object in a different model view will be resolved by code changes made to the upcoming release of our software NX 8.5.

6674021

Siemens PLM believes that the problem you reported where importing an NX Nastran deck from within command finder will be resolved by code changes made to the upcoming release of our software NX version 8.5.

Page 151: NX_Errors - 8.5

6674145

Siemens PLM believes that the problem you reported where properties were missing when importing data from gateway will be resolved by code changes made to the upcoming release of our software NX 8.5.

6675478

Siemens PLM believes that the problem you reported where the results manipulation tool generates incorrect data when combining Ansys load case results will be resolved by code changes made to the upcoming release of our software NX 8.0.3.

6675587

Siemens PLM believes that the problem you reported where a Planar Mill operation shows as 'Regenerate' if a Chamfer Mill is used will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6675622

Siemens PLM believes that the problem you reported where selecting the Animation option 'Reverse Play' shows erroneous arc moves will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6676261

Siemens PLM believes that the problem you reported where the Remark on the NX Open API Reference Guide page for the NXOpen > DisplayModification > NewColor property contained incorrect information, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6676436

Siemens PLM believes that the problem you reported where the Weld Assistant Plug Weld took a long time to select edge curves, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6676498

Siemens PLM believes that the problem you reported where you received a UNV file import error in the postprocessing navigator will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

6676937

Siemens PLM believes that the problem you reported where a Polygon pattern did not update after editing the original curves, will be resolved by documentation changes made to the upcoming release of our software NX 8.5. The documentation for the Pattern Curve command in Sketcher already includes user help for the Polygon layout type. It is found in the help topic: "Pattern Curve non-associated options," which is located in both the table of contents under Pattern Curve, and in the Quick Links that appear on the right side of all Pattern Curve help topics under the "Look up more details" heading. The lead-in sentence for the "Pattern Curve non-associative options" topic, now states: "These additional non-associative Pattern Curve options are only available if you disable Create Inferred Constraints."

6677004

Siemens PLM believes that the problem you reported where additional documentation is needed to explain how the revision is determined during a Save As in Teamcenter. will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6677106

Siemens PLM believes that the problem you reported where the Turning IPW is wrong after a milling operation will be resolved by code changes made to the upcoming release of our software NX 8.5.

6678666

Siemens PLM believes that the problem you reported where the calculation of the Minimum Distance is not correct.will be resolved by code changes made to the upcoming release of our software NX 8.5.

6680656

Siemens PLM believes that the problem you reported where the Check-Mate xml log file format had a problem with the status attribute for a checker that passes, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 152: NX_Errors - 8.5

6680987

Siemens PLM believes that the problem you reported where a Post Processor created in Post Builder NX 5.0.3 and then saved in PB NX 8.0.1 will not work from NX 8.0.1 will be resolved by code changes made to the upcoming release of our software NX 8.5.

6681383

Siemens PLM believes that the problem you reported where an error message was received that the geometry is invalid for the mesh recipe will be resolved by code changes made to the upcoming release of our software NX 8.5.

6681968

Siemens PLM believes that the problem you reported where the Routing Classification procedure was not documented will be resolved in the upcoming release of our software NX 8.5.

6682159

Siemens PLM believes that the problem you reported where "Workpiece-> Show spinning 3D" produces a sheet body instead of a solid body will be resolved by code changes made to the upcoming release of our software NX 8.5.

6684079

Siemens PLM believes that the problem you reported where CampbellCsvToAfu_original.vb need to be updated for NXN 7.1 format will be resolved by code changes made to the upcoming release of our software NX Advanced Version 8.5.

6684556

Invalid Object error, opening assembly saved as precise with ref components.

6685005

Siemens PLM believes that the problem you reported where changing the cut direction in streamline causes an error will be resolved by code changes made to the upcoming release of our software NX 8.5.

6685026

Splitting a solid causes the body to be on the current Work Layer.

6685344

Siemens PLM believes that the problem you reported where it was not possible to get faces or edges from a HolePackage feature in NX Open without resorting to the wrapped UF methods will be resolved by code changes made to the upcoming release of our software NX 8.5.

6685371

Siemens PLM believes that the problem you reported where intermittent Internal Error messages are displayed when generating a tool path will be resolved by code changes made to the upcoming release of our software NX 8.5.

6685625

Siemens PLM believes that the problem you reported where Contour Profile is causing the tool to lift in some places will be resolved by code changes made to the upcoming release of our software NX 8.5 It should be noted that the tool path was spiking down at the start and end of the tool path also. This was fixed. The pr indicated that the tool path lifted up in places but this was due to the Contour Profile rule of not allowing the tool to go below the Trace curve i.e. Wall Bottom. Once the spike was fixed the tool path is smooth and correct.

6686893

Siemens PLM believes that the problem you reported where a post produces different NC code when being upgraded from PB NX 6.0 to PB NX 7.5 will be resolved by code changes made to the upcoming release of our software in PB NX 8.5. A work-around has been provided to the customer for verification.

6687003

Siemens PLM believes that the problem you reported where a bolt circle centerline loses associativity editing view positions with Edit-view-Move/copy view, will be resolved by code changes made to the upcoming release of our software NX 8.5.

66872 Siemens PLM believes that the problem you reported where a Heidenhain post outputs an

Page 153: NX_Errors - 8.5

03 incorrect feed rate will be resolved by code changes made to the upcoming release of our software NX 8.5.

6687495

Numeric input not taken when APPLY is pressed.

6687813

Siemens PLM believes that the problem you reported where 'Extract Virtual Curve -> Virtual intersection' is not working for Variable Blend will be resolved by code changes made to the upcoming release of our software NX 8.5. We have added notes to the Extract Virtual Curve overview topic in the documentation: "Only rolling ball (constant radius) face and edge blends are supported" This was added to the end of the following overview topic bullets: * Extract the centerline of blend faces. * Extract the virtual intersection of a blend face. Also added the following sentence near the end of the overview topic: NOTE: Extract Virtual Curve does not support chamfers.

6687969

Siemens PLM believes that the problem you reported where a Closed Hem Flange could not be created, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6688018

Siemens PLM believes that the problem you reported where mesh on a given part collapsed or tapered to a narrow edge along an edge common to two volumes will be resolved by code changes made to the upcoming release of our software NX 8.5.

6688156

Siemens PLM believes that the problem you reported where the NXOpen Programmer's Guide did not provide information about whether or not the wrappers for the NXOpen.UF "free" methods needed to be used or not, will be resolved by documentation changes made to the upcoming release of our software NX 8.5. Starting in NX 8.5, the unnecessary methods will no longer be included in the NXOpen.UF namespace.

6688473

Siemens PLM believes that the problem you reported where an error occurs when deleting a newly created instanced operation that crashes manufacturing will be resolved by code changes made to the upcoming release of our software NX 8.5.

6688679

Siemens PLM believes that the problem you reported where posting from the sync manager in TC, folders in C:\\Temp have the wrong names will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6689097

Siemens PLM believes that the problem you reported where the "Along Vector" and "Rotate Using Points" is missing from the Motion options in the documentation will be resolved by code changes made to the upcoming release of our software NX 8.5.

6689203

Siemens PLM believes that the problem you reported where a component was added to an assembly but it wasn't available in Motion Simulation will be resolved by code changes made to the upcoming release of our software NX 8.0.1 and NX 8.5.

6689250

Siemens PLM believes that the problem you reported where the act of suppressing/un-suppressing a component does not remove/add its name to the graphics display when the setting of Preferences->Visualization, Names/Borders, Object Name Display is Work View, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6690148

Siemens PLM believes that the problem you reported where attempting to delete the leader of a Note raised the error: "Attempt to free already free memory in Storage Manager", will be resolved by code changes made to the upcoming release of our software NX 8.5.

66902 Siemens PLM believes that the problem you reported where the properties dialog for CAM

Page 154: NX_Errors - 8.5

27 objects will show the wrong (i.e. previous) name in the dialog and thus allow for accidentally renaming the object will be resolved by code changes made to the upcoming release of our software NX 8.5.

6690816

Siemens PLM believes that the problem you reported where overlaid elements in 1D connection listed both elements in the Simulation navigator, but only displayed one of the elements, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5. Development has also provided the following information: Now we are allowing the user to create coincident elements in point to point and node-to-node connection. While creating connection, if coincident elements are created, a pop up warning message will come and ask whether coincident element should be created or not.

6690982

Siemens PLM believes that the problem you reported where the Operation Path Display dialog - shows motion types not used by the operation will be resolved by code changes made to the upcoming release of our software NX 8.5.

6691109

Do we have a solution for PR06604898.

6692623

Siemens PLM believes that the problem you reported where milling operations are inheriting the feedrate unit from the Method parent instead of the cut will be resolved by code changes made to the upcoming release of our software NX 8.0.3 and NX 8.5.

6693494

Siemens PLM believes that the problem you reported where selecting instance geometry feature of points was not selecting points to project, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6694121

Siemens PLM believes that the problem you reported where the NX Open C function UF_WAVE_ask_link_mirror_data() returns a "File not found" error when querying the linked mirror feature, even when the allow_load parameter is set to TRUE, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6694508

Siemens PLM believes that the problem you reported where the mass flow results display incorrectly in NX 8.0.1, will be resolved by code changes made to the upcoming release of our software NX Thermal/Flow, version 8.5. Development provided the following explanation: This is a Unit conversion issue. Current work around is to import result with "User Defined" unit system.

6696089

Siemens PLM believes that the problem you reported where there are errors placing a detail view, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6696184

Siemens PLM believes that the problem you reported where PMI View not matching imported drawing view will be resolved by code changes made to the upcoming release of our software NX 8.5.

6696236

Siemens PLM believes that the problem you reported where no method is written for frequency analysis in NX8 will be resolved by code changes made to the upcoming release of our software NX Advanceed Simulation Version 8.5.

6696254

Siemens PLM believes that the problem you reported where an error: "Error number: 1" was raised when importing a STEP file into NX, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6696324

Siemens PLM believes that the problem you reported where the Tracelines of a Printed Circuit Board did not maintain their thickness when imported into NX as a DXF file, using "File ->

Page 155: NX_Errors - 8.5

Import -> DXF/DWG", will be resolved by code changes made to the upcoming release of our software NX 8.5.

6696755

Siemens PLM believes that the problem you reported where FEAT GCURVE IJK vectors post processed by NX CMM are incorrect will be resolved by code changes made to the upcoming release of our software NX 8.5.

6696836

Siemens PLM believes that the problem you reported where editing a multi-depth parameter causes an error that says "drive geometry must be specified" will be resolved by code changes made to the upcoming release of our software NX 8.5.

6696899

NX manager not enforcing naming rules.

6697458

Same issue as as PR 1861711 - TC831/NX7554.

6697704

Siemens PLM believes that the problem you reported where exporting a PDF fails if the dataset name or file name contains a slash, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6698151

Siemens PLM believes that the problem you reported where Part Stock values are not being applied when there are many cut areas will be resolved by code changes made to the upcoming release of our software NX 8.5.

6698315

Siemens PLM believes that the problem you reported where the curves in the sim file were not selected will be resolved by code changes made to the upcoming release of our software NX 8.5.

6699859

Draftiing sketch opens when I change the drawing sheet.

6700032

Siemens PLM believes that the problem you reported where in an AFEM the solution checker does not provide missing midsurface error will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

6700376

Siemens PLM believes that the problem you reported where documentation for the "Convex Corner" options "Extend" and "Extend and Trim" needed updating to add information that the "Corner" settings "Extend/Extend and Trim" only applies to the cut along the part will be resolved by code changes made to the upcoming release of our software NX 8.5.

6700550

Siemens PLM believes that the problem you reported where the Design Feature 'Hole' does not create a circular edge in a sheet body will be resolved by code changes made to the upcoming release of our software NX 8.5.

6700597

Siemens PLM believes that the problem you reported where the file pointed to by UGII_ENV_FILE could fail to load, and the user would not be warned, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6702170

Siemens PLM believes that the problem you reported where Global shaping by function - radius reduction generates bad result will be resolved by code changes made to the upcoming release of our software NX 8.5.

6702308

Siemens PLM believes that the problem you reported where Feature Playback failed, reporting a circular dependency error, will be resolved by code changes made to the upcoming release

Page 156: NX_Errors - 8.5

of our software NX 8.5.

6702791

Siemens PLM believes that the problem you reported where the documentation for the Return of the Knowledge Fusion function ug_curve_askPlaneIntersection incorrectly stated that a point would be returned rather than parameters, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6702883

Siemens PLM believes that the problem you reported where variables for stock allowances are not documented in the mom variable browser will be resolved by code changes made to the upcoming release of our software NX 8.5.

6702996

Graphics error when creating a blend.

6703491

Siemens PLM believes that the problem you reported where Element material orientation does not display correctly in NX 8.0.1 compared to NX 7.5.5 is working as designed to improve performance and now this information is added to the upcoming release of our NX 8.5 documentation as well.

6703591

Siemens PLM believes that the problem you reported where generating an operation displays Internal Error after changing the cut direction will be resolved by code changes made to the upcoming release of our software NX 8.5.

6703721

Siemens PLM believes that the problem you reported where the Approach/Departure is omitted in ZigZag w/ lifts but worked in NX6 will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6704810

Siemens PLM believes that the problem you reported where the SampleNXOpenApplications\\.NET\\SpellChecker example application needed updating, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6705062

Anchor point of symbol created by Import is far from the symbol.

6705505

Siemens PLM believes that the problem you reported where Machine Code Simulate is ignoring the Tool--> Y Mount value in ISV will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6705657

Edge Blend regression.

6705949

Siemens PLM believes that the problem you reported where VNC commands were not getting upgraded in Post Builder NX 8.0.2 will be resolved by code changes made to the upcoming release of our Post Builder software in NX 8.0.3 and NX 8.5.

6705971

Font Weight Issue with Tabular Notes.

6706338

Cyclical Dependancy error reported in a Turning program.

6706500

Orienatation inside NX is lost.

Page 157: NX_Errors - 8.5

6706686

Siemens PLM believes that the problem you reported where the Units changed for Orbit Definition Solar Flux, are not remembered will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

6707498

Siemens PLM believes that the problem you reported where face analysis display has turned off some surfaces, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6707502

Siemens PLM believes that the problem you reported where the message to warn of an unavailable Studio Render license was not displayed during an Artistic Image rendering will be resolved by code changes made to the upcoming release of our software NX 8.5.

6707998

Parent Part Geometry Selection - Inconsistent Selection Intent.

6708079

Show 3D IPW brings an error Access memory violation.

6708319

Siemens PLM believes that the problem you reported where Callout IDS do not update in the Assembly Navigator will be resolved by code changes made to the upcoming release of our software NX 8.5.

6708405

Siemens PLM believes that the problem you reported where the Siemens 840D post template has an invalid MOM_set_seq_on command will be resolved by code changes made to the upcoming release of our software NX 8.5.

6708461

Siemens PLM believes that the problem you reported where a turning teachmode operation creation fails with a tcl error will be resolved by code changes made to the upcoming release of our software NX 8.5.

6708559

Siemens PLM believes that the problem you reported where the issue reported in PR 6596681 was not fixed in the versions reported (NX 8.0.1.5 mp1 and NX 8.0.2), will be resolved by code changes made to the upcoming release of our software NX 8.0.3 and NX 8.5. PR 6596681 reported that Global Deformation recorded in a journal (without any license errors) could not be played back, reporting a license error.

6708679

Siemens PLM believes that the problem you reported where NX wireframe entities were causing problems with the JT bounding box, will be resolved by changes made to the upcoming release of our software NX 8.0.3 and NX 8.5.

6708875

Variable Contour Operations Tool Axis Toward Point is Not Associative.

6709420

Siemens PLM believes that the problem you reported where Check-Mate was reporting objects on layer zero will be resolved by code changes made to the upcoming release of our software NX 8.5.

6711864

Siemens PLM believes that the problem you reported where Bridge Curve - Deviation gage puts needles at ends with cross-curve deviation will be resolved by code changes made to the upcoming release of our software NX 8.5.

6712179

Siemens PLM believes that the problem you reported where identify causes exception in the model will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5.

Page 158: NX_Errors - 8.5

6712214

Siemens PLM believes that the problem you reported where the Knowledge Fusion documentation did not sufficiently warn against working with duplicate class/function definitions, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6713539

Siemens PLM believes that the problem you reported where selecting drive curves hangs NX will be resolved by code changes made to the upcoming release of our software NX 8.5.

6714404

Siemens PLM believes that the problem you reported where the Documentation on how to turn on the review tool in Shop Documentation is outdated will be resolved by code changes made to the upcoming release of our software NX 8.5.

6715240

Siemens PLM believes that the problem you reported where some labels are truncated when the dialog initially opens will be resolved by code changes made to the upcoming release of our software in NX Motion Simulation Version 8.5. All motion dialogs are Width Style now which show all label strings and show all strings for unit string.

6715243

Siemens PLM believes that the problem you reported where the graph lable is not updated after the sensor is edited will be resolved by code changes made to the upcoming release of our software NX Motion Simulation Version 8.5.

6715274

Siemens PLM believes that the problem you reported where with max/min values for ALL Addresses is being changed when only one of the addresses is actually modified will be resolved by code changes made to the upcoming release of our software NX 8.5.

6715838

Siemens PLM believes that the problem you reported where UF_WAVE_is_link_broken is returning broken wave features that cannot be found will be resolved by code changes made to the upcoming release of our software NX 8.5. The part submitted with this PR has been repaired by our development team. You can download this repaired file at this URL: http://download.ugs.com/special.php/returned/amj59198-clean.geo_fin001.005000_f ixed.prt.zip.

6716035

Siemens PLM believes that the problem you reported where creating a custom unit results in a syntax error will be resolved by code changes made to the upcoming release of our software NX 8.5.0. There are two defects in the dialog. Both issues are resolved in NX 8.5. A description of the issue and a work arounds for each are listed below. The issue is that spaces are not allowed in either the Unit Name or the Unit Display Name. The dialog ignores any characters after the first blank in the Unit Name, which is annoying but at least creates an usable unit with a portion of the intended name. Worse, the Display Name is accepted with blanks but then fails later when the new unit is used in the Material dialog. The work around for this defect is to enter names without blanks: "GPa (kN/mm^2)" -> "GPa(kN/mm^2)" The second defect is a failure of the dialog to update an internal table when the Unit Display Name is changed (and the Update Unit button is pushed). The first work around is to avoid changing the Unit Display Name in the dialog. The second potential work around is to delete and re-create the unit if the original display name is incorrect. This works only if the unit has not yet been used in an Expression or Material.

6716337

Siemens PLM believes that the problem you reported where there is no explanation in the docs for the machine rigidity parameter in the machining data library, will be resolved by code changes made to the upcoming release of our software is NX 8.5.

6716863

Siemens PLM believes that the problem you reported where the documentation for the NXOpen.Features > ExtractFaceBuilder class property FrecAtTimeStamp was insufficient, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 159: NX_Errors - 8.5

6717955

Cloned assembly components get substituted with original component.

6718011

Siemens PLM believes that the problem you reported where a Post Builder V5.0.3 5axis Table/Table postprocessor saved in Post Builder V8.0.2 outputs a rotary move from a Cavity Milling operation after the tool is machining inside the part will be resolved by code changes made to the upcoming release of our software NX 8.5. In the interim a postprocessor with the upcoming fix has been provided to you by GTAC CAM Support.

6718403

Siemens PLM believes that the problem you reported where exporting an .ADM file and importing into MSC/ADAMS didn't work correctly will be resolved by code changes made to the upcoming release of our software NX 8.5. There are 3 issues in this PR.

Issue 1 about duplicate bodies is the same as PR6702489 and has been fixed in NX 8.5. Issue 2 about couplers also has been fixed in NX 8.5. The coupler scale will now not contain zero values. Issue 3 about 3D contacts is much more difficult to fix.

There are quite different ways to deal with contact between MSC/ADAMS and RecurDyn. At present it is not possible for RecurDyn to create a good *.ADM file with a contact object. Please contact the GTAC Coordinator if you would like to submit an Enhancement Request to ask that this functionality be included in some future version of the product.

6718407

Siemens PLM believes that the problem you reported where a warning was raised when compiling the NXException.hxx, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6718578

Crosshatch region is updated incorrectly after model change.

6718730

Need 'Active Sketch View' in RMB for all views when there is no active sketch.

6718813

X-Hatching doesnt become retained even boundary becomes to open.

6719495

Insert "Base View"-> Select another non-master loaded part gives wrong result.

6719571

Edit sketch pattern curve gives wrong result.

6719833

Siemens PLM believes that the problem you reported where drill operations will not simulate correctly will be resolved by code changes made to the upcoming release of our software NX 8.5.

6720010

Can he use the NX browser.

6720062

Siemens PLM believes that the problem you reported where the documentation incorrectly stated for SOL 601 that the temperature-dependent stress-strain curve is supported only for nonlinear elastic material properties will be resolved by code changes made to the upcoming release of our software NX 8.5.

67202 Even if you select icon in Toolber area, wrong condition will be displayed.

Page 160: NX_Errors - 8.5

52

6720338

Copy& Paste(Reuse Original) Sketch: Edit dim is not update to parent immediately.

6720416

Siemens PLM believes that the problem you reported where placing an ID symbol in a projected view containing faceted representations returned a Modeler Error will be resolved by code changes made to the upcoming release of our software NX 8.5.

6720489

Siemens PLM believes that the problem you reported where the C++ function prototype, that was generated for the OnMenuCallback of the Tree List block, used the misleading third parameter name of "menuItemID" rather than "columnID", will be resolved by code changes made to the upcoming release of our software NX 8.5.

6720600

Siemens PLM believes that the problem you reported where the Qualify Sketch utility did not fail a sketch that was missing a Default Anchor Point, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6720625

Siemens PLM believes that the problem you reported where dragging and dropping a PTS template always added the template using the "Entire Part" Reference Set, even though the template had been defined using a different Reference Set, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6720691

CAM: The results of the "Optimize" causes the collision with workpiece.

6720926

Boundary conditions of canceled analysis type are displayed.

6720929

Handles for Instance Clocking is displaying in incorrect place.

6720932

Contour Flange - Section selection: Curve rule-> Feature Curves is not working.

6721112

Snap point selection for Arc center gives wrong result in Lighweight Rep.

6721202

Sketch add-on command cannot be launch in direct sketch with Delay update ON.

6721301

Siemens PLM believes that the problem you reported where no notifications or alerts are raised following changes made to the Grade or Thickness in the Plate Material spreadsheet, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6721373

Siemens PLM believes that the problem you reported where notification must be given if any changes are made to the values for any column data in a profile data spreadsheet, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6721640

Siemens PLM believes that the problem you reported where demandOrder did not work to control the timestamp of a feature when its class was switched back from nullDesign by changing an Expression value using "Tools -> Expression", will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 161: NX_Errors - 8.5

6721723

Siemens PLM believes that the problem you reported where loading a FEM file, after opening the SIM file takes a long time when the FEM has a lot of groups, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

6721781

Character corruption in Laminate.

6721821

Pattern Feature along curve gives wrong result if pattern instance is selected.

6721844

Datum Target with Stack annotation on extended leader stub note behaves strange.

6721875

Select Spline for Unbend feature with Additional curves takes time to complete.

6722021

Siemens PLM believes that the problem you reported where NX failed to load a PTS template if parenthesis or operators had been entered in a label's title within the template, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6722251

Siemens PLM believes that the problem you reported where Highlight Original was not documented in the NX 8 Help Library, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6722276

Siemens PLM believes that the problem you reported where pressing MB2 does not update the Blend feature with a new Blend Radius value, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6722982

Siemens PLM believes that the problem you reported where the second optimized face creates a self-intersection and fails to shade will be resolved by code changes made to the upcoming release of our software NX 8.5.

6723045

Siemens PLM believes that the problem you reported where the tool axis vector for a CIRCLE/ record is different in NX 7.5 & NX 8 but was the same in NX 6 will be resolved by code changes made to the upcoming release of our software in NX 8.5 Work-around was also provided as temporary fix for earlier versions of NX with the same issue.

6723315

Siemens PLM believes that the problem you reported where an incorrect error message was received saying that a spider element cannot have more than one dependent node will be resolved by code changes made to the upcoming release of our software NX 8.5.

6723435

Siemens PLM believes that the problem you reported where labels were truncated on the Parameters dialog will be resolved by code changes made to the upcoming release of our software NX 8.5.

6723668

Siemens PLM believes that the problem you reported where exporting a part to its component was not working as expected will be resolved by code changes made to the upcoming release of our software NX 8.5.

6724503

The problem where a sketch object got in the way of feature update and playback has been fixed. The sketch object was orphaned and should have been deleted. We found an error in our cleanup code that was skipping over some sketch objects and not cleaning them up properly. In NX 8.5, the internal checking code and cleanup code have been adjusted and the part is properly cleaned. A cleaned part has been saved for the user in NX 6.0.5 and is available from GTAC. The part succeeds in Feature Playback and the manual test in NX

Page 162: NX_Errors - 8.5

207107 succeeds as well in a NX 8.5 ip17 project.

6724576

Siemens PLM believes that the problem you reported where the Split Body behavior changed, causing part of the split body to move to the work layer, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6725269

UDF Causes Internal Error: Memory Access Violation.

6725425

Siemens PLM believes that the problem you reported where Translucency and shininess not plotted correctly when exporting a PDF, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6725430

Siemens PLM believes that the problem you reported where an internal error occurs when selecting entities to re-orient view. will be resolved by code changes made to the upcoming release of our software NX 8.5.

6725547

Siemens PLM believes that the problem you reported where replacing an Extrude feature with a Datum Plane causes the Tool feature in a Trim Body to become lost will be resolved by code changes made to the upcoming release of our software NX 8.5.

6725907

Siemens PLM believes that the problem you reported where importing of PTP files back into Teamcenter is not automatically picking the correct directory to import into will be resolved by code changes made to the upcoming release of our software NX 8.5.

6726544

Siemens PLM believes that the problem you reported where a filter callback was not able to discern the current Block Styler block will be resolved by code changes made to the upcoming release of our software NX 8.5.

6726594

Siemens PLM believes that the problem you reported where you were unale to insert NX 4 udf in NX 7.5 will be resolved by code changes made to the upcoming release of our software NX 8.5 This PR had three problems: 1. Inseting UDF s_melt_channel_07 as per PR in NX 7.5.5 would give an error - "Unable to Paste". This has been fixed in this PR. 2. Once the "Unable to Paste" error above is fixed, after instantiation, one of UDF expression which was formual in the definition part would become a constant in the instantiation part. This has also been fixed by this PR fix. 3. One of the UDF expression is a formula comprising of a measure expression that belongs to a geometric-expression feature. This geometric expression feature is part of the UDF. While instantiating, the measure expression would convert to a constant expression. This problem cannot be fixed. This is a regression from NX 4 because of the expression copy changes done for UDF instantiation. To regain the NX4 behavior one can turn ON the environment varibale - UGII_UDFS_DISABLE_UI_EXPRESSION_COPY=1. It seems like problem 3 is the main issue that Husky is concerned about in this PR. We have communicated to Husky the info regarding the environment variable. Awaiting word from them to see if they are still interested in fixes for 1 and 2 in NX 7.5.5 MP. Closing this PR as fixed in NX 8.5 phase 21 where problems 1 and 2 above have been fixed.

6726620

Siemens PLM believes that the problem you reported where update failures were found when updating the entire assembly will be resolved by code changes made to the upcoming release of our software NX 8.5.

6726714

Siemens PLM believes that the problem you reported where a GRIP N/C program that created a tool correctly in NX 6 produces error in NX 8 when edited will be resolved by code changes made to the upcoming release of our software in NX 8.5. Tools created in GRIP N/C will no

Page 163: NX_Errors - 8.5

longer give an invalid parameter error when edited interactively and saved.

6727260

File size grows every time that the paths are regenerated.

6727261

Siemens PLM believes that the problem you reported where "Return" under Motion Type on a Linear Move puts End-of-path commands in the wrong location will be resolved by code changes made to the upcoming release of our software NX 8.5.

6728098

Siemens PLM believes that the problem you reported where in Non Cutting Moves, selecting tabs is ineffective because the selected tab is not opened will be resolved by code changes made to the upcoming release of our software NX 8.5.

6728417

Siemens PLM believes that the problem you reported where frozen parts updated when opened, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6728769

Siemens PLM believes that the problem you reported where the three text references (with broken links) reported in this PR have therefore been removed from the Expressions dialog box topic will be resolved by code changes made to the upcoming release of our software NX 8.5.

6728942

Siemens PLM believes that the problem you reported where the translation declash markers caused an ssue with running mqc_report_entities_with_filters will be resolved by code changes made to the upcoming release of our software NX 8.5.

6728985

Siemens PLM believes that the problem you reported where the dynamic rotation performance of a model in post processing is slow, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

6729334

Siemens PLM believes that the problem you reported where filters for entities "Types" was not remembered, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6729571

Siemens PLM believes that the problem you reported where Areafills in PMI symbols did not show up in scaled drawing views, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6730040

Siemens PLM believes that the problem you reported where documentation for IPW Flow does not state that the components in the Source Part and Work Part must be the same, not a new component with a name match, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6730158

Siemens PLM believes that the problem you reported where there is no tool preview if the 'Display' controls are customized off the tool dialog will be resolved by code changes made to the upcoming release of our software NX 8.5. If the Preview Display Customizable item is not defined, then the preview display value will be determine from customer default settings.

6730174

CheckMate test failing.

6730447

Siemens PLM believes that the problem you reported where registered cloning callbacks were not invoked as expected when using Add Part, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 164: NX_Errors - 8.5

6730769

Loading Machine Tool with Structure Only set does not simulate.

6731024

Siemens PLM believes that the problem you reported where the Material Version Control message did not indicate parts where out-of-date materials reside, will be resolved by code changes made to the upcoming release of our software NX 8.5. The problem where a part with an updated material may not be saved is also fixed in release NX 8.5. The request for an ability to quickly identify out-of-date materials has been documented in an ER.

6731095

Step file export not working from Teamcenter V8 on single machine.

6731202

Siemens PLM believes that the problem you reported where GRIP N/C created a tool with the old dialog will be resolved by code changes made to the upcoming release of our software NX 8.5. Tools created in GRIP N/C will have the same dialog tabs as a new tool when they are subsequently edited interactively.

6731653

Siemens PLM believes that the problem you reported where DisplayFacets causes the NX session to crash will be resolved by code changes made to the upcoming release of our software NX 8.5.

6731842

Siemens PLM believes that the problem you reported where invalid Ordinate Dimensions displayed incorrect values in NX , when using the Ordinate Set in the part that was created in NX6, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6732265

Siemens PLM believes that the problem you reported where the status for a generated Variable Streamline operation goes to "Regenerate" after the operation is generated will be resolved by code changes made to the upcoming release of our software NX 8.5.

6732280

Siemens PLM believes that the problem you reported where the tool axis vector for interpoloated tool axis did not update when the cut area was changed will be resolved by code changes made to the upcoming release of our software NX 8.5.

6733144

Siemens PLM believes that the problem you reported where Verify 3D shows many IPW collisions but when using the suppress animation option, none were shown will be resolved by code changes made to the upcoming release of our software in NX 8.5.

6733233

Siemens PLM believes that the problem you reported where the Planar Mill Cut Level options do not match the NX Help Docs will be resolved by code changes made to the upcoming release of our software NX 8.5.

6733376

Trying to insert Dwell in ISV and not seeing it in PTP file later.

6734004

Siemens PLM believes that the problem you reported where for CBUSH elements, using 'Identy' command's 'List output to information window' option only listing the active output to the information window will be resolved by code changes made to the upcoming release of our software NX 8.5.

6735225

Siemens PLM believes that the problem you reported where group security on end items causes NX open to fail will be resolved by code changes made to the upcoming release of our software NX 8.5.

6735912

Siemens PLM believes that the problem you reported where internal error occurs during replace component, will be resolved by code changes made to the upcoming release of our

Page 165: NX_Errors - 8.5

software NX 8.5.

6735972

NXOpen::BlockStyler::Tree control: SetSelectedIcon not working as expected.

6736059

Siemens PLM believes that the problem you reported where the hole table does not recognize reference components, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6736246

Siemens PLM believes that the problem you reported where material data is not correctly imported from an ABAQUS model will be resolved by code changes made to the upcoming release of our software NX 8.5.

6736249

Siemens PLM believes that the problem you reported where BEAM GENERAL SECTION did not import correctly will be resolved by code changes made to the upcoming release of our software Advanced Simulation Version 8.5.

6736252

Siemens PLM believes that the problem you reported where no *CONTACT PAIR was imported from the supplied model will be resolved by code changes made to the upcoming release of our software NX 8.5.

6736283

Siemens PLM believes that the problem you reported where the wrong units were displayed in an annotation on a bending moment will be resolved by code changes made to the upcoming release of our software NX 8.5.

6737186

Preferences ' Manufacturing ' Visualization ' Colors ' Auto Block & NX 8.

6737410

Siemens PLM believes that the problem you reported where Attributes are lost when Runs are defined using 'compare stubs' will be resolved by code changes made to the upcoming release of our software NX 8.5 and a fix was also submitted for the next maintenance pack for NX 8.0.2.

6737552

Siemens PLM believes that the problem you reported where stress recovery points are incorrect for an oval section will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation Version 8.5. This fix will also be available in NX 8.0.3 MP3 Delta or MP4.

6737606

Siemens PLM believes that the problem you reported where an OD grooving operation recuts the groove walls after each cleanup pass will be resolved by code changes made to the upcoming release of our software NX 8.5.

6738177

Siemens PLM believes that the problem you reported where cbar offsets are not imported from MSC Nastran correctly will be resolved by code changes made to the upcoming release of our software NX version 8.5.

6738448

Siemens PLM believes that the problem you reported where editing an existing attribute value raised the message: "The attribute string value is too long", will be resolved by code changes made to the upcoming release of our software NX 8.5. The problem where some string attributes are wrongly limited to 1 character has not been reproduced. However, a potentially related problem has been fixed in release NX 8.5.

6739562

Materiial library not updated during upgrade.

Page 166: NX_Errors - 8.5

6739664

Siemens PLM believes that the problem you reported where File Close All -An operation was attempted on an invalid or unsuitable OM object will be resolved by code changes made to the upcoming release of our software NX 8.5.

6741811

Siemens PLM believes that the problem you reported where an error occurs when the distance constraint is modified in the Assembly Navigator, will be resolved by code changes made to the upcoming release of our software NX 8.5. In addition, the problem part file has been cleaned in NX 7.5.5 and uploaded to the PR data as "A5300057_1_cleaned.prt".

6742608

Internal error when inserting a sheet.

6743448

Siemens PLM believes that the problem you reported where the Common Depth per Cut option is not explained adequately in the docs will be resolved by code changes made to the upcoming release of our software NX 8.5. The following was added to documentation in Milling -> Path Settings -> Cut Levels -> Cut Levels dialog box -> Cut Levels - Common Depth per Cut: NX applies the Common Depth per Cut value to all the ranges except when you specify a local Depth per Cut value for a range in the Cut Levels dialog box. The local Depth per Cut value overrides the Common Depth per Cut value.  - If you change the Common Depth per Cut value, and all local Depth per Cut values are the same, NX changes the Depth per Cut value for each range to the Common Depth per Cut value. - If you change the Common Depth per Cut value, and the local Depth per Cut values are different, NX warns you that the local depths per cut will be reset to the new global value.

6743451

UG-CAM: Fixed Contour ignores Drive Sets when Drive Method is set to Curve/Point.

6743840

Siemens PLM believes that the problem you reported where 'View -> Section -> Edit Work Section -> Offset -> Step', failed to work will be resolved by code changes made to the upcoming release of our software NX 8.5.

6743845

Siemens PLM believes that the problem you reported where the documentation did not explain what the Preferred Part Material was, and where it is defined, will be resolved by documentation changes made to the upcoming release of our software NX 8.5. A new topic has been added: "Designate a preferred material for a part or FEM" that describes the non-Teamcenter workflow. The Teamcenter integration with the Reuse Library is only supported with a special TC customization, so that particular workflow will not be documented until the Reuse Library integration works in the general, non-customized software (in a future release, TBD).

6744156

Siemens PLM believes that the problem you reported where it was not possible to create a Plug Weld in an open-ended Slot as the documentation states, will be resolved by documentation changes made to the upcoming release of our software NX 8.5. We have corrected the Plug/Slot Dialog used in NX.7.5 and introduced a new one in NX.8.0. In NX 7.5 the picture suggested that an open slot can be filled in, which is not the case (the rectangular slot must be closed). In NX.8.0 and higher, there is no such suggestion. The documentation is also misleading as the algorithm in NX.7.5 (and in NX.8.0 and higher) was not designed to fill an open slot. We thank you for bringing up the issues and we should correct the documentation as we definitely require that the rectangular slot be closed before we can apply Plug/Slot feature.

6744159

Siemens PLM believes that the problem you reported where a Plug Weld was created incorrectly if the hole was on a curved/cylindrical surface, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 167: NX_Errors - 8.5

6744797

Siemens PLM believes that the problem you reported where documentation on the 'Feed Adjustment on Arcs' function does not fully explain what it does will be resolved by code changes made to the upcoming release of our software NX 8.5. The revised description is as follows: On All Arcs Applies an adjustment factor to compensate for variations in chip loads when milling corners. - Min Compensation Factor specifies the smallest adjustment factor to increase or decrease the feed rate. - Max Compensation Factor specifies the largest adjustment factor to increase or decrease the feed rate.

6745207

Siemens PLM believes that the problem you reported where the Check-Mate functions mqc_askDrawingViewDependentEntity and mqc_askDrawingViewDependentObject return objects which cannot be seen, will be resolved by code changes made to the upcoming release of our software NX 8.5. A new function mqc_askVisibleViewDependentObject has been created which should be used instead to avoid the unseen objects.

6745723

UF_GDT_ask_tags creates or makes entities visible on layer 1.

6745783

Siemens PLM believes that the problem you reported where some of the Functions Descriptions are not displayed in the Function Builder, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6747076

Siemens PLM believes that the problem you reported where the SOL 601,129 Solution dialog box help topic about Rayleigh damping didn't match the description in the NX Nastran Advanced Nonlinear manual will be resolved by code changes made to the upcoming release of our software NX 8.5.

6747154

Siemens PLM believes that the problem you reported where the PROGRAM NAME does not come out on tool list html/excel is the result of the documentation not explictly stating that not all variables on the second page of the Shop Documentation spreadsheet will be resolved by code changes. This has been corrected in the upcoming release of our software NX 8.5. The NX 8 documentation reads: MOM variables are dynamic, and change based on the operation. They may be added or changed with each release. To get the most complete list of MOM variables use the MOM Variable browser found in Post Builder under Utilities-> Browse MOM Variables. Note: Some variables related directly to the tool path are available only during postprocessing, and are not available in Shop Documentation. If you need to use these, you should use a Post to generate your Shop Documentation. There are many variables available while a shop document is being generated. Different variables are available, depending on what objects are being cycled. For example, mom_tool_diameter is available for a milling tool, but would not be applicable for another object, such as a program or operation The list on the second sheet of the spreadsheet is for reference only. You can use variable names there for copy and paste if they are applicable to your operation.

6747187

Siemens PLM believes that the problem you reported where Mirror Curve in Sketch is not properly updating will be resolved by code changes made to the upcoming release of our software NX 8.5.

6747196

Unable to clone export asm "internal error".

6747738

Siemens PLM believes that the problem you reported where an "Internal error: memory access violation" was raised exporting an assembly outside of Teamcenter, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 168: NX_Errors - 8.5

6748044

Siemens PLM believes that the problem you reported where the model setup check issues a warning when running a axisymmetric model containing PID controllers will be resolved by code changes made to the upcoming release of our software NX 8.5.

6748136

Siemens PLM believes that the problem you reported where if there is a space in the path name postprocessing fails when postprocessing with a linked post will be resolved by code changes made to the upcoming release of our software NX 8.5.

6748578

Siemens PLM believes that the problem you reported where the Assemblies Help needed updating to show the two new icons used for Reference-only objects in the Assembly Navigator, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6748596

Siemens PLM believes that the problem you reported where Unable to load NX 7.5 assembly into NX 8 (managed and native) will be resolved by code changes made to the upcoming release of our software NX 8.5.

6749222

"Show Degrees of Freedom" function shows wrong DOFs.

6749588

Siemens PLM believes that the problem you reported where missing CAM files causes a tcl error in NX CMM when retrieving a machine will be resolved by code changes made to the upcoming release of our software in NX 8.5. The cmm_inspection/resource/postprocessor folder is no longer dependent on the UGII_CAM_POST_DIR folder.

6749611

Siemens PLM believes that the problem you reported where entering a long path into the Replace Component Visual Rule truncated the dialog, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6749914

Siemens PLM believes that the problem you reported where the last selected tab was not presented in the Create New Component dialog, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6751231

Siemens PLM believes that the problem you reported where the Knowledge Fusion Help and Best Practices documentation did not clearly state that Optional function arguments must always be specified as name-value pairs, will be resolved by documentation changes made to the upcoming release of our software NX 8.5.

6752074

Siemens PLM believes that the problem you reported where Modeler error occurred when updating" message when updating a view in NX 8 will be resolved by code changes made to the upcoming release of our software NX 8.5.

6752983

Siemens PLM believes that the problem you reported where viewing a lightweight section view raised the error: "Arrow aligned index provided does map to a dimension extension line", will be resolved by code changes made to the upcoming release of our software NX 8.5.

6753559

Siemens PLM believes that the problem you reported where you were unable to align the balloons created by Auto Balloon from a Parts List, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6753588

Siemens PLM believes that the problem you reported where the NXOpen > RuleManager > Evaluate method returned an array of zeros when used with a reference chain to an attribute which is a List of valid hostpointers will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 169: NX_Errors - 8.5

6754662

Siemens PLM believes that the problem you reported where when a bolt connection command is used in an assembly fem to have a bolt added to connect two walls of the same component fem using mesh point (with 'Center point' and Face method) and saving the sim file resulting in 'General fault exception' error will be resolved by code changes made to the upcoming release of our software NX 8.5.

6754818

Siemens PLM believes that the problem you reported where simulation does not stop on a collision between defined component pairs will be resolved by code changes made to the upcoming release of our software NX 8.5. Note: See the following NX 8.0.2 caveat about workpiece pairs: "The _WORKPIECE/any other geometry collision pair does not support collision checking for Turning operations."

6755593

Siemens PLM believes that the problem you reported where opening the FEM file AFTER modifying and saving the ipart (without the fem in session) failing to load the fem with "Internal Error" will be resolved by code changes made to the upcoming release of our software NX 8.5.

6756310

Siemens PLM believes that the problem you reported where the Post Builder documentation is not clear when extracting Tracking Point data will be resolved by code changes made to the upcoming release of our software NX 8.5.

6757059

Siemens PLM believes that the problem you reported where an animation of strain energy density incorrectly displays negative values will be resolved by code changes made to the upcoming release of our software NX 8.5.

6760388

Siemens PLM believes that the problem you reported where it wasn't possible to export enforced displacements using a field with ABAQUS will be resolved by code changes made to the upcoming release of our software NX 8.5. Please note that this issue is documented in the NX8.0 Release Notes as follows: Help, Release Notes, NX 8 Caveats and Product Notes, CAE (Digital Simulation), Caveats, Advanced Simulation Abaqus import and export The following issues currently occur when you export or solve an Abaqus input file from NX: In the Enforced Displacement Constraint dialog box, if you select the Components - spatial option, NX does not write out the load to the input file.

6762163

Siemens PLM believes that the problem you reported where creating a new SIM from a particular FEM file uses too much memory, will be resolved by code changes made to the upcoming release of our software NX Advanced Simulation, version 8.5.

6762478

Siemens PLM believes that the problem you reported where the Customer Default for the User XML/HTML Template Files Directory is being ignored, will be resolved by code changes made to the upcoming release of our software NX 8.5.

6762751

Siemens PLM believes that the problem you reported where pattern feature not successfully patterning edge blend will be resolved by code changes made to the upcoming release of our software NX 8.5. The nature of the resolution required it to be versioned to new Pattern Features created in NX 8.5 and later. Please delete and recreate the "Pattern [Circular] (17)" in NX 8.5 to get the correct results. The Edge Blend(12) at each instance is applied on all the corresponding edges with the new Pattern [Circular] feature.

6763450

Siemens PLM believes that the problem you reported where NX running out memory in the surface-area drive method will be resolved by code changes made to the upcoming release of our software in NX 8.6 delta 2.

6764693

Siemens PLM believes that the problem you reported where updating a sketch section raised an internal error, will be resolved by code changes made to the upcoming release of our software NX 8.5.

Page 170: NX_Errors - 8.5

6764753

Siemens PLM believes that the problem you reported where Section Curve updates resulted in extra curves causing downstream update failures, will be resolved by code changes made to the upcoming release of our software NX 8.5. Please note that the fix is applicable to Section Curve Features created in NX 8.5 or later. This is because the fix requires a version control. The fix cannot be back-ported because the feature update could fail if the fix is not version protected.

6765874

Unable to delete sketch from file due to unknown Circular Reference error.

6768331

Siemens PLM believes that the problem you reported where NX crashes when using the Mold Wizard Concept Design will be resolved by code changes made to the upcoming release of our software NX 8.5.

6769614

The problem where turning feedrates from pre-NX 8 are not migrating properly after generating has been investigated and the following has been found. Development was not able to reproduce the problem without the part file mentioned in the PR text because export compliance for the part was not granted.