NUUO Input / Output solution · External Device Matrix Type Model Description Converter SCB-C08 USB...
Transcript of NUUO Input / Output solution · External Device Matrix Type Model Description Converter SCB-C08 USB...
NUUO Input / Output solution
Outline
External Device Matrix
I/O Functions
Interact with Main console
Interact with external devices
I/O Practices 1. Main Console + IP camera IO
2. Main Console + IO converter + IO Box
3. Main Console + C08 + Analog PTZ camera
NUUO IO & POS solution Matrix
Troubleshooting
External Device Matrix
External Device Matrix
Type Model Description
Converter SCB-C08 USB to RS232/422/485 converter
I/O Box (require C08)
SCB-C24 16 Digital Output Insolated (RS485)
SCB-C26 16 Digital Input Insolated (RS485)
SCB-C28 4 Isolated Digital Input & 4-ch Power Relay Output (RS485)
I/O Card (require DVR)
S-IO 4 Isolated Digital Input & Power Relay Output (RS232 to RS485)
Converter SCB-C31A RS232/485 to TCP converter *On Main Console: POS *On NVRmini/NVRmini 2: POS / IO
I/O Devices
*C08: USB to RS485 converter
IO box (RS485 module)
C24: 16 output
C26: 16 input
*C28: 4 input, 4 output *hands-on practice
Able to cascade up to 256 IO units
IO Functions
I/O Functions
Input ( , )
General Actions (Emap/PTZ/Output)
Start Recording
Start Smart Guard
Output device ( , )
Triggered by event
Triggered by input
General Actions
IO Control Panel on Main console
Also available on Remote Live Viewer
Find the input log in Log Viewer
IO Practice
Target:
Control IP camera output
Steps:
1. Make sure the IP camera support RS485 IO
2. Add IP can on Main Console
3. Control IO on Main Console
I/O Practice 1: Main Console + IP camera IO
I/O Practice 2: Main Console + IO converter + IO Box
Targets:
Config input trigger output
Config event (ex: motion) trigger output
Config record by event (input as a event)
Config input trigger Smart Guard
Config input snapshot to FTP
Steps:
1. Install C08 Driver
2. Config IO devices parameter by IOConfig_C24_26_28
3. Add IO devices on Main Console
4. Do necessary configuration
Connection layout
USB
RS485
RS485
RS485
DI 0 DI 1 Device to DI 0
Device to DI 1
(+) to device (-) to IN-COM External power supply Input
External power supply
Output 1
Output 0
Device to RL2-COM
Device to RL1-COM
(+) to device
(+) to device
(-) to RL1 ON & RL2 ON
Output
I/O Practice 3: Methods to control analog camera PTZ
Cable
RS485
RJ45
RS485
Coaxial cable
USB
Via video server
Via PT driver
External PT driver
RS485
RJ45
C08
Video server
Via C08
I/O Practice 3: Main Console + C08 + Analog PTZ camera
Targets
Control analog camera PTZ
Steps:
1. Install C08 Driver
2. Config PTZ protocol on camera
3. Config ID address on camera
2. Config PTZ protocol 3. Config ID address
4. Config parameters on Main Console
I/O Practice 3
NUUO IO & POS solution Matrix
NUUO IO and POS solution matrix
Product Type Main Console NVRmini NVRmini S NVRmini 2 Titan NVR
Models All versions NV-4080 NV-4160
NV-2020 NV-2040
NV-4080S NV-4160S
NE-4080 NE-
4160
NE-2020 NE-2040
NT-4040 NT-4040R
IO solution: C31/C31A + C24/26/28
Yes Yes Yes Yes Yes Yes
IO solution: C08 + C24/26/28
Yes
POS solution: via SCB-C31A
Yes Yes Yes Yes Yes
POS solution: via SCB-C31
Yes Yes Yes Yes Yes Yes
POS solution: via TCP client
Yes Yes Yes Yes Yes
If I want to connect IO devices on Main Console:
If I want to connect IO devices on NVRmini / Titan
If I want to connect POS devices on Main Console / NVRmini / Titan
FAQ
FAQ
Q: Can I use SCB-C31A in Main console as an IO converter from RS-485 to TCP/IP?
A: No, Main console will only use SCB-C31A-POS to connect to POS. For IO converter, Main console use SCB-C08 only
Q: Can I use SCB-C08 in NVRmini / Titan as an IO converter from RS-485 to USB?
A: No, SCB-C08 is not compatible with NVRmini / Titan at all
FAQ
Q: What’s the difference between SCB-C31A and SCB-C31A-POS?
A: SCB-C31A is used in NVRmini and Titan only and act as an IO converter, no need to activate POS license
SCB-C31A-POS can be used both in NVRmini / Titan and Main console as an RS-232 to TCP/IP converter and need to activate POS license
FAQ
Q: When use C08 do analog speed dome PTZ, what search tool to shall I use to find the parameters (PTZ protocol, ID address)
A:User need to config the rotate switch on camera directly.
Q: Why sometime the search tool can not find C24/26/28?
A: Please try to reset the IO box by:
1. Plug in, 12 up
2. Plug out, 1 down.
3. Plug in, 1 up 2 down.
FAQ
Q: Why sometime the search tool show “Fail to detect on COM15” when the COM port number is large?
A: Please config the port to a smaller number ex: COM1~COM5.
COM--> property --> port settings --> advance)
Q&A