Numerical Investigation of Three-Dimensional Plasma ... · Numerical Investigation of...

9
Numerical Investigation of Three-Dimensional Plasma Actuation for Improving Film Cooling Effectiveness Subrata Roy University of Florida, Gainesville, Florida 32611 and Chin-Cheng Wang Yuan Ze University, Taoyuan 32003, Taiwan, Republic of China DOI: 10.2514/1.T3945 We numerically test a horseshoe plasma actuator for film cooling enhancement on a flat plate. We solve three- dimensional plasma governing equations using the finite element based MIG flow code. The electric force density calculated from the plasma governing equations is then employed as a body force density into a finite volume based NavierStokes solver with standard turbulence models for controlling the flow. Such electric force influences attachment of the cold jet to the work surface by actively altering the three-dimensional flowfield in the vicinity of the actuator. We consider two problems related to film cooling. The first problem is to understand the influence of a horseshoe plasma actuator on a flowfield where the cooling jet and the bulk flow speeds are of the same order of the flow induced by plasma itself. The second problem is to validate a previously reported film cooling experiment with a single row of round cooling holes issuing at a 35 deg angle on a flat plate, and then predict any improvement due to plasma actuation. For a unit blowing ratio, the results are compared with the published experimental data and other numerical predictions. The numerical results show a progressive improvement of centerline effectiveness as the electric force density is increased from 0 (no force) to 8 MNm 3 (maximum). Specifically, an improvement of effectiveness well above 100% is predicted over the standard baseline design for the latest film cooling technology. Nomenclature d = circular pipe diameter, m D e;i = electron or ion diffusion coefficient, m 2 s E = electric field, Vm e = elementary charge, 1.6022 × 10 19 C F = electric force density, Nm 3 k B = Boltzmanns constant, 1.3807 × 10 23 JK M = blowing ratio n e;i = electron or ion density, 1m 3 p = pressure, torr q = separated space charge density, 1m 3 r = recombination rate, m 3 s T = local static temperature, K V = gas velocity, ms α = Townsend coefficient, 1m α a = jet issuing angle Γ e = electron flux, 1m 2 s ε 0 = permittivity of free space, 8.8542 × 10 12 Fm η = film cooling effectiveness μ e;i = electron or ion mobility, m 2 sV ρ = gas density, kgm 3 ϕ = potential, V Subscripts e = electron fs = freestream i = ion j = cooling jet s = work surface I. Introduction C ROSSFLOW jets have been widely successful in many engineering problems including the film cooling of gas turbine blades. These blades suffer from very high thermal stresses due to hot effluent gases from the combustion chamber. The problem worsens with increasing turbine inlet temperature used for higher thermal efficiency. Repetitive thermal stress over a long duration significantly affects the lifetime of turbine blades. There are several methods of cooling turbine blades for increasing their lifetime. Film cooling is one of the most promising of such methods, where cold jets are injected through rows of surface holes located in the spanwise direction on the blade. These jets penetrate into the hot freestream gas forming a three-dimensional (3-D) bound vortical structure that promotes attachment of a thin film of cold gas over the blade surface, protecting it from thermal stress. In traditional designs, the attachment of the cold jet to the blade surface becomes aggressively difficult as the momentum ratio of the injected air to the crossflow (i.e., the blowing ratio M) increases, causing a local lift off of the cold film just downstream of the cooling hole. Haven and Kurosaka [1] examined the effect of the hole exit geometry on near field characteristics of crossflow jets in a canonical fashion. From the experimental observation shown in Fig. 1, we can see the liftoff behavior of the kidney vortices as the cold jet interacts with the hot freestream gas. Numerous numerical studies have been performed for improving cooling effectiveness by reducing liftoff effect. Roy [2] showed that lowering the issuing angle maximizes the cooling efficiency. Walters and Leylek [3] provided an understanding of the flow physics for different film hole lengths, diameter ratios, and blowing ratios using cylindrical cooling holes. Hyams and Leylek [4], Azzi and Jubran [5], and Zhang and Hassan [6] presented different shaped holes for detailed analysis of film-cooling physics. The results indicated that changes in film-cooling hole shape could strongly affect the downstream behavior of the film. Na and Shih [7] proposed a ramp modification upstream of the holes to modify the interaction of Presented as Paper 2010-1092 at the 48th AIAA Aerospace Sciences Meeting Including the New Horizons Forum and Aerospace Exposition, Orlando, FL, 47 January 2010; received 1 May 2012; revision received 29 January 2013; accepted for publication 28 February 2013; published online 4 June 2013. Copyright © 2013 by the American Institute of Aeronautics and Astronautics, Inc. All rights reserved. Copies of this paper may be made for personal or internal use, on condition that the copier pay the $10.00 per-copy fee to the Copyright Clearance Center, Inc., 222 Rosewood Drive, Danvers, MA 01923; include the code 1533-6808/13 and $10.00 in correspondence with the CCC. *Associate Professor, Mechanical and Aerospace Engineering. Associate Fellow AIAA. Assistant Professor, Mechanical Engineering, 135, Yuan-Tung Rd. Chung-Li; [email protected]. Member AIAA. AIAA Early Edition / 1 JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER Downloaded by UNIVERSITY OF FLORIDA on June 5, 2013 | http://arc.aiaa.org | DOI: 10.2514/1.T3945

Transcript of Numerical Investigation of Three-Dimensional Plasma ... · Numerical Investigation of...

Page 1: Numerical Investigation of Three-Dimensional Plasma ... · Numerical Investigation of Three-Dimensional Plasma Actuation for Improving Film Cooling Effectiveness Subrata Roy∗ University

Numerical Investigation of Three-Dimensional Plasma Actuationfor Improving Film Cooling Effectiveness

Subrata Roy∗

University of Florida, Gainesville, Florida 32611

and

Chin-Cheng Wang†

Yuan Ze University, Taoyuan 32003, Taiwan, Republic of China

DOI: 10.2514/1.T3945

We numerically test a horseshoe plasma actuator for film cooling enhancement on a flat plate. We solve three-

dimensional plasma governing equations using the finite element based MIG flow code. The electric force density

calculated from the plasma governing equations is then employed as a body force density into a finite volume based

Navier–Stokes solver with standard turbulence models for controlling the flow. Such electric force influences

attachment of the cold jet to the work surface by actively altering the three-dimensional flowfield in the vicinity of the

actuator. We consider two problems related to film cooling. The first problem is to understand the influence of a

horseshoe plasma actuator on a flowfield where the cooling jet and the bulk flow speeds are of the same order of the

flow induced by plasma itself. The second problem is to validate a previously reported film cooling experiment with a

single row of round cooling holes issuing at a 35 deg angle on a flat plate, and then predict any improvement due to

plasma actuation. For a unit blowing ratio, the results are compared with the published experimental data and other

numerical predictions. The numerical results show a progressive improvement of centerline effectiveness as the

electric force density is increased from 0 (no force) to 8 MN∕m3 (maximum). Specifically, an improvement of

effectiveness well above 100% is predicted over the standard baseline design for the latest film cooling technology.

Nomenclature

d = circular pipe diameter, mDe;i = electron or ion diffusion coefficient, m2∕sE = electric field, V∕me = elementary charge, 1.6022 × 10−19 CF = electric force density, N∕m3

kB = Boltzmann’s constant, 1.3807 × 10−23 J∕KM = blowing ratione;i = electron or ion density, 1∕m3

p = pressure, torrq = separated space charge density, 1∕m3

r = recombination rate, m3∕sT = local static temperature, KV = gas velocity, m∕sα = Townsend coefficient, 1∕mαa = jet issuing angleΓe = electron flux, 1∕m2sε0 = permittivity of free space, 8.8542 × 10−12 F∕mη = film cooling effectivenessμe;i = electron or ion mobility, m2∕sVρ = gas density, kg∕m3

ϕ = potential, V

Subscripts

e = electron

fs = freestreami = ionj = cooling jets = work surface

I. Introduction

C ROSSFLOW jets have been widely successful in manyengineering problems including the film cooling of gas turbine

blades. These blades suffer from very high thermal stresses due to hoteffluent gases from the combustion chamber. The problem worsenswith increasing turbine inlet temperature used for higher thermalefficiency. Repetitive thermal stress over a long duration significantlyaffects the lifetime of turbine blades. There are several methods ofcooling turbine blades for increasing their lifetime. Film cooling isone of the most promising of such methods, where cold jets areinjected through rows of surface holes located in the spanwisedirection on the blade. These jets penetrate into the hot freestream gasforming a three-dimensional (3-D) bound vortical structure thatpromotes attachment of a thin film of cold gas over the blade surface,protecting it from thermal stress. In traditional designs, theattachment of the cold jet to the blade surface becomes aggressivelydifficult as the momentum ratio of the injected air to the crossflow(i.e., the blowing ratioM) increases, causing a local lift off of the coldfilm just downstream of the cooling hole. Haven and Kurosaka [1]examined the effect of the hole exit geometry on near fieldcharacteristics of crossflow jets in a canonical fashion. From theexperimental observation shown in Fig. 1, we can see the liftoffbehavior of the kidney vortices as the cold jet interacts with the hotfreestream gas.Numerous numerical studies have been performed for improving

cooling effectiveness by reducing liftoff effect. Roy [2] showed thatlowering the issuing angle maximizes the cooling efficiency. Waltersand Leylek [3] provided an understanding of the flow physics fordifferent film hole lengths, diameter ratios, and blowing ratios usingcylindrical cooling holes.Hyams andLeylek [4],Azzi and Jubran [5],and Zhang and Hassan [6] presented different shaped holes fordetailed analysis of film-cooling physics. The results indicated thatchanges in film-cooling hole shape could strongly affect thedownstream behavior of the film. Na and Shih [7] proposed a rampmodification upstream of the holes to modify the interaction of

Presented as Paper 2010-1092 at the 48th AIAA Aerospace SciencesMeeting Including the New Horizons Forum and Aerospace Exposition,Orlando, FL, 4–7 January 2010; received 1 May 2012; revision received 29January 2013; accepted for publication 28 February 2013; published online 4June 2013. Copyright © 2013 by the American Institute of Aeronautics andAstronautics, Inc. All rights reserved. Copies of this paper may be made forpersonal or internal use, on condition that the copier pay the $10.00 per-copyfee to the Copyright Clearance Center, Inc., 222 Rosewood Drive, Danvers,MA 01923; include the code 1533-6808/13 and $10.00 in correspondencewith the CCC.

*Associate Professor, Mechanical and Aerospace Engineering. AssociateFellow AIAA.

†Assistant Professor, Mechanical Engineering, 135, Yuan-Tung Rd.Chung-Li; [email protected]. Member AIAA.

AIAA Early Edition / 1

JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER

Dow

nloa

ded

by U

NIV

ER

SIT

Y O

F FL

OR

IDA

on

June

5, 2

013

| http

://ar

c.ai

aa.o

rg |

DO

I: 1

0.25

14/1

.T39

45

Page 2: Numerical Investigation of Three-Dimensional Plasma ... · Numerical Investigation of Three-Dimensional Plasma Actuation for Improving Film Cooling Effectiveness Subrata Roy∗ University

incoming flow and cooling jet. Their results showed that a rampdesign gave two times higher laterally averaged effectiveness thanwithout a ramp.For more accurate numerical simulation, Garg [8] and Heidmann

et al. [9] considered realistic film-cooled turbine vane geometryincluding the plenum and hole pipes with Wilcox’s κ-ω turbulencemodel [10]. These studies provide good details of the flow. However,the spanwise vortices are complex to resolve using κ-ω turbulencemodel. The two competing factors limiting any turbulence modelsefficacy in capturing these processes are computational accuracy andefficiency (i.e., CPU cost). Researchers used large-eddy simulation(LES) and direct numerical simulation (DNS) to capture small andlarge scale flow details. Zhong and Brown [11] conducted DNS forsolving a 3-D film cooling problem with multiple holes. Theycomputed cooling effectiveness that showed good agreement withexperimental results for low blowing ratio cases of M � 0.25 andM � 0.43. However, bothDNS andLES are computationally limitedfor high Reynolds number flows. As a remedy, a detached eddysimulation (DES) turbulence model is widely used for capturingreasonable description of the dynamic flow structures at higherReynolds numbers. For example, Kapadia et al. [12], Martini et al.[13], andKim andHassan [14] performedDESof film-cooling flows.Their results indicate that the mixing process downstream of the holeis highly anisotropic due to a much stronger turbulent diffusionprocess in the transverse direction.Several experimental efforts [15–17] have been also documented

in the literature. Sinha et al. [15] provided detailed experimental datafor film cooling effectiveness with different density ratios andblowing ratios on a flat plate with a row of inclined holes. The resultsshowed that the centerline effectiveness scaled with the massflux ratio and that the laterally averaged effectiveness dependedon density ratio and momentum flux. Bell et al. [16] studied fivedifferent shaped holes for different blowing ratios, momentum fluxratios, and density ratios. Some of these designs increase lateralspreading of the cold jet. Bunker [17] also provided a review of theshaped holes for film cooling. He summarized that shaped holes hadhigher centerline and spanwise effectiveness than round holes andconcluded that for shaped holes the cooling effectiveness showedlittle variation over a range of blowing ratio (0.5 ≤ M ≤ 2). Ekkadet al. [18] investigated cooling effectiveness for different blowingratios (0.25 ≤ M ≤ 2) for a range of jet pulsing frequencies between5 and 20 Hz, and duty cycle levels between 10 and 100%. Resultsindicate the higher effectiveness and lower heat transfer coefficientsare obtained at the reduced duty cycles. Bogard and Thole [19]provided a thorough review of the literature on physical descriptionsand various influences on film cooling performance. It was foundthat there are strong influences of freestream turbulence, surfacecurvature, and hole shape on the performance of film cooling.The complex dynamic nature of a film-cooling flow makes it a

candidate for active control using a dynamic force that variestemporally and spatially working with the dominant turbulence

scales. Reported experimental and numerical results show thatdielectric barrier discharge (DBD) actuators are effective incontrolling the flow [20,21]. Surface compliance, rapid response,lack of moving parts, and easy installation are a few advantagesof plasma actuators. Specifically, due to the lack of mechanicalcomponents, the lifetime of the actuator could be significantlyextended as compared to other mechanical/electromechanicaldevices such as synthetic jet actuators. We proposed a concept usingplasma electric force to actively enhance interaction of cool air jetswith hot crossflow for improved cooling of hot surfaces [22,23]. Thehot freestream gas will enhance dissociation and hence, help plasmageneration due to ionization in the vicinity of the electrodes. Bothpulsed dc- and ac-powered plasma actuators can induce such activecontrol over the dynamics of film cooling. A novel aspect of theseactuators is that one may vary the spatial and temporal scales overwhich the energy is added. The momentum transfer between theplasma and gas happens due to collisional momentum transferbetween charged ions and neutral atoms. Such actuation of the flow isactive and near instantaneous, does not require anymechanical parts,and the actuator electrode sets can be applied as a patch on the surfaceof the existing ceramic coating of the turbine blade or embeddedinto the coating. There could be practical considerations likesurface oxidation of the electrodes and spallation. In our prior study,we employed a phenomenological electric force model along ahorseshoe geometry for the 3-D flow simulation [23]. Here, we solvethe fully 3-Dgoverning equations for the plasma and flow simulation.The 3-D electric force density is calculated from the electric field andthe space charge separated plasma density. Assuming that the plasmatimescales are orders of magnitude smaller than the flow timescale,we use the time average of the electric force distribution as a bodyforce in the Navier–Stokes equations.

II. Problem Description

We employ a horseshoe-shaped plasma actuator with twoasymmetrically displaced curved electrodes separated by a dielectric(insulating) material. One of the electrodes is exposed to the airand the other one is encapsulated within the dielectric material. Theneighboring gas ionizes over the exposed surface due to an appliedelectric field between these two electrodes that are powered with asinusoidal voltage difference at a kHz frequency. The discharge isdriven by a high electric field (∼106 V∕m) that triggers electronemission from the instantaneous cathode. These electrons collidewith neutral molecules of the working gas initiating ionization, andresulting in a separated space charge.As a product of this electric fieldand the space charge, an electrohydrodynamic (EHD) body force isinduced. Interestingly, irrespective of the polarity of the electrodes,the majority of the EHD force is directed from the exposed electrodeto the grounded electrode [24].Starting from plasma principles, we study two separate problems

to understand the effect of plasma actuation on a film-cooling flow.Problem I is the thermal stress management for a very low speed

Fig. 1 Schematics show a) kidney vortices due to the hole sidewall vorticity and b) kidney vortices at downstream of the coolant hole with elliptic holegeometry [1].

2 AIAA Early Edition / ROYANDWANG

Dow

nloa

ded

by U

NIV

ER

SIT

Y O

F FL

OR

IDA

on

June

5, 2

013

| http

://ar

c.ai

aa.o

rg |

DO

I: 1

0.25

14/1

.T39

45

Page 3: Numerical Investigation of Three-Dimensional Plasma ... · Numerical Investigation of Three-Dimensional Plasma Actuation for Improving Film Cooling Effectiveness Subrata Roy∗ University

(laminar) hot gas flow over a flat plate. We consider two differentpowering schemes to generate plasma forces as shown in Fig. 2 andcompare themwith film cooling in the absence of plasma forces. Thebaseline casewith no plasma effect is shown in Fig. 2a and horseshoeplasma actuators with different setups are shown in Figs. 2b and 2c.For all cases in problem I, the hot freestream gas comes from the xdirectionwith uniformvelocity of 0.3 m∕s and temperature of 300K.The cold jet comes froma coolant hole and injects into the bulk regionwith an angle of 45 deg, velocity of 0.42 m∕s, and temperature of150K. To reduce high enthalpy related issues, the temperatures of thefreestream gas and the coolant jet are chosen based on [15]. Allboundary conditions are shown in Fig. 3. We impose velocity inletconditions at x � 0 and x � 0.0003 m and a zero pressure outletcondition at x � 0.0006 m. Symmetry boundaries are maintained aty � 0 and 0.0006 m. At the bottom wall, an adiabatic no-slip wallboundary condition is imposed. The flow actuation is done by a set ofhorseshoe-shaped electrode pairs between which electric potentialgenerates an electric body force that is dominant inside the viscousboundary layer. We apply a voltage ϕ > 0 to the inner electrode andground the outer electrode to create an outward electric force from the

horseshoe actuator. Contrarily, the outer electrode is powered and theinner electrode is grounded for generating an inward directed plasmaforce. The latter arrangement will generate a force that will reducethe jet momentum coming out of the coolant hole. Note that theseelectrodes are separated by a thin 0.00002 m dielectric barrier ofKapton between them. The plasma actuation is directly linked with anear-instantaneous Lorenzian momentum coupling between the gasand the charged particles. Figure 3 shows the top view and the sideview of the computational domain for the first problem.Problem II is film cooling with a realistic velocity ratio (i.e.,

Vj∕Vfs) of 0.5. We compare our numerical results with Sinha et al.’sexperiment [15] for validation purposes. Figure 4 describes thecontrol volume of freestream air passing over a flat (blade) surfacethat is an adiabatic wall with an inward directed plasma force near thecoolant hole. This flat surface has a row of injection holes throughwhich the cool air is issued at an angle αa � 35 deg. The cool jet attemperature Tj � 150 K is injected into the hot freestream ofTfs � 300 K. The injection ducts are circular pipes with diameterequal to d � 0.00254 m. The injection hole formed by theintersection of the injection pipe with the wind tunnel is an ellipsewith the minor and the major axes d and D � d∕�sin αa�),

x z

y

50 V

Ground

x z

y

50 V

Ground

a)

b) c)Fig. 2 Schematics show the a film-cooling flow for a) the baseline case, b) the case of an outward plasma force, and c) the case of an inward plasma force.

50 V 0 V

Velocity Inlet

Pressure Outlet

Blade Surface

Hot Freestream

Cold Jet

Symmetry

Symmetry

x

z

y

x

Fig. 3 Schematics show the top view and the side view of an inwardarrangement of computational domain.

Exit : x/d= 29

α a

Periodic: y/d = -1.5

Periodic: y/d = 1.5

Freestream Inlet : x/d = -20

Wall : x/d = -14

Wall : x/d = 8

Wall: z/d = -2

Wall: z/d = 0

Far field: z/d = 20

Coolant Inlet: z/d = -6

x y

z

Fig. 4 Schematic shows the geometry and boundary conditions arebased on reported test setup [15].

AIAA Early Edition / ROYANDWANG 3

Dow

nloa

ded

by U

NIV

ER

SIT

Y O

F FL

OR

IDA

on

June

5, 2

013

| http

://ar

c.ai

aa.o

rg |

DO

I: 1

0.25

14/1

.T39

45

Page 4: Numerical Investigation of Three-Dimensional Plasma ... · Numerical Investigation of Three-Dimensional Plasma Actuation for Improving Film Cooling Effectiveness Subrata Roy∗ University

respectively. The distance between the hole centers is L � 3d. Theselected mean flow velocities, static pressures, and temperatures(i.e., densities) in the injection pipe and the wind tunnel gives ablowing ratio M � 1. The freestream inlet section is located atx � −20d and the exit is located at x � 29d. The mass flow ratemaintained at the freestream inlet is 0.05372 kg∕s, whereas that forthe coolant inlet is 0.003 kg∕swith a density ratio of ρj∕ρfs � 2 anda velocity ratio ofVj∕Vfs � 0.5. The exit is maintained at zero gaugepressure. The domain extends from the plenum base at z � −6d toz � 20d where a pressure-far-field boundary condition is applied.The periodic boundary condition is applied in the crosswise direction(at y � �1.5d) in the computational domain. For the coolantplenum, a no-slip wall condition is applied at x∕d � −14 and �8,and z∕d � −2 surfaces. The mass flow inlet condition that wouldensure a blowing ratio of unity is assumed at z∕d � −6. Otherdimensions and boundary conditions are shown in Fig. 4. Forstandard DBD actuators, the electric force density is measured to be∼kN∕m3, which consumes tens ofW of power [24]. However, suchsmall electric force density may not be useful to control the flow overthe actual turbine blade. The electric force density has to be threeorders of magnitude higher than the standard RF plasma actuator.Even such higher force density (∼MN∕m3) will only use a smallfraction of power (less than 1% of the turbine power) for such anarrangement, which may eventually reduce the energy budget bymore effective cooling.Two important parameters for comparing film cooling perfor-

mance are the effectiveness η and the blowing ratio M. Theeffectiveness is defined as η � �Tfs − Ts�∕�Tfs − Tj�, where Ts, Tj,and Tfs are the work surface, cooling jet, and freestream gastemperatures, respectively. The blowing ratio is the momentum ratioof the jet over the freestream M � ρjVj∕ρfsVfs � 1, based on thework of Sinha et al. [15]. The density ρj and velocityVj of the fluid atthe jet exit plane are related to the freestream density ρfs and velocityVfs such that ρj∕ρfs � MVfs∕Vj. The turbulence intensity isdefined as I � u 0∕U, where u 0 is the rms of the turbulent velocityfluctuations andU is themean velocity. Here, I � 0.05 is maintainedbased on the calculated turbulent kinetic energy.

III. Numerical Model

We employ a hydrodynamicmodel formultiscale dielectric barrierdischarge simulation at atmospheric pressures. The model usesan efficient finite element algorithm. The unsteady transport forelectrons and ions is derived from fluid dynamics in the form of massconservation equations. The speciesmomentum ismodeled using thedrift–diffusion formulation under local thermal equilibrium approxi-mation that can be derived from the hydrodynamic equation [25]. Thecontinuity equations for ion and electron number densities andPoisson's equation are given by

∂ni∂t� ∇ · �niVi� � αjΓej − rnine

∂ne∂t� ∇ · �neVe� � αjΓej − rnine

jΓej ����������������������������������������������������������������neVe�2x � �neVe�2y � �neVe�2z

q(1)

niVi � niμiE −Di∇ni neVe � −neμeE −De∇ne (2)

∇ · �εE� � e�ni − ne� � eq (3)

where ne and ni are number densities of electron and ion,respectively, q is the separated space charge density,V (Vx,Vy,Vz) isthe species hydrodynamic velocity, and the electric field E (Ex, Ey,Ez) is given byE � −∇φ (i.e., the gradient of electric potentialφ). InEqs. (1–3), r ∼ 2 × 10−13 m3∕s is the electron-ion recombinationrate, ε is the dielectric constant, and subscripts i and e denote positiveion and electron, respectively. The discharge is maintained using a

Townsend ionization scheme. The ionization rate is expressed as afunction of electron drift velocity jΓej and Townsend coefficient α:

α � Ap exp�−B�jEj∕p�� (4)

where A and B are preexponential and exponential constants,respectively, and p is the pressure. The system of Eqs. (1–3) isnormalized using the following normalization scheme: τ � t∕t0,zi � xi∕d, Ne � ne∕n0, Ni � ni∕n0, ue � Ve∕VB, ui � Vi∕VB,ϕ � eφ∕kBTe where kB is Boltzmann’s constant, VB �

�������������������kBTe∕mi

pis the Bohm velocity, reference length d is usually a domaincharacteristic length in the geometry, the reference time is t0 � 10−8 s,and the reference density is n0 � 1015 m−3. The ion mobility anddiffusion at 300 K, as well as electron mobility and diffusion at11,600 K (i.e., 1 eV), are given by Surzhikov and Shang [26]. We donot apply an external magnetic field, and the induced magnetic field isnegligible. Finally, the following equations are solved:

∂ni∂t� ∂

∂x

�niμiEx −Di

∂ni∂x

�� ∂

∂y

�niμiEy −Di

∂ni∂y

� ∂∂z

�niμiEz −Di

∂ni∂z

�� αjΓej − rnine

∂ne∂t� ∂

∂x

�−neμeEx −De

∂ne∂x

�� ∂

∂y

�−neμeEy −De

∂ne∂y

� ∂∂z

�−neμeEz −De

∂ne∂z

�� αjΓej − rnine (5)

where μi � 1.45 × 10−1∕p �m2∕sV� is the ion mobility, μe �4.4 × 10∕p �m2∕sV� is the electron mobility, Di and De are the ionand electron diffusion coefficients, respectively, calculated from theEinstein relation that is a function of ion and electron mobility as wellas ion and electron temperature, i.e., Di � μiTi and De � μeTe. Foran electric potential of 106 V∕m under atmospheric pressure with abulk gas density of 2.48 × 1025 m−3, the reduced electric field isapproximately equal to 40 Td. Based on the solution of Boltzmannequation [27] at this condition, the electron mobility is equal to0.05835 m2∕Vs, which is within 1% of the value (0.05789 m2∕Vs)calculated using the approximate equation given in [26]. The followingboundary conditions are enforced for the plasma simulation. At theexposed electrode, the electronic flux is based on the electron thermalvelocity and is directed toward the electrode. The positive ion fluxnormal to the exposed electrode is considered to be zero if the electricfield is directed away from the electrode. The initial ion and electronnumber densities are assumed to be uniform and equal to 1015 m−3 inthe plasma domain, whereas these charged particle densities are set tozerowithin the dielectric material. Based on a sheath analysis reportedfor a similar problem [25], the smallest mesh size is kept at 10−5 m,which is enough to capture the relevant physics within the sheaththickness under this condition. A fixed time step of 10−11 s (of theorder of dielectric relaxation time) is employed for solving plasmaequations.We apply time average of the electric force density (F � eEq)

calculated from Eqs. (3–5) in the Navier–Stokes equations as a bodyforce for an incompressible Newtonian fluid shown next:

∇ · V � 0 ρDV

Dt� −∇p� F� μ∇2V ρcp

DT

Dt� kH∇2T �Φ

(6)

where ρ is the fluid density,V is the fluid velocity vector, μ is the fluidviscosity, kH is the fluid conductivity, T is the fluid temperature, andΦ denotes the viscous dissipation.Equations (5) and (6) are discretised using a finite element method

(FEM) based module driven 3-D MIG (multiscale ionized gas) flowcode. The in-house MIG flow code has been verified and used formany applications such as plasma governing equations and Navier–Stokes equations. Computed solutions show details of the distributionof charged and neutral particles and their effects on the flow dynamics[22,23,25]. The forward temporal evolution is evaluated using the fully

4 AIAA Early Edition / ROYANDWANG

Dow

nloa

ded

by U

NIV

ER

SIT

Y O

F FL

OR

IDA

on

June

5, 2

013

| http

://ar

c.ai

aa.o

rg |

DO

I: 1

0.25

14/1

.T39

45

Page 5: Numerical Investigation of Three-Dimensional Plasma ... · Numerical Investigation of Three-Dimensional Plasma Actuation for Improving Film Cooling Effectiveness Subrata Roy∗ University

implicit time stepping procedure. The Newton–Raphson scheme isused for dealing with nonlinear terms. To solve the sparse matrix, weemploy the iterative GMRES (generalized minimal residual) solver.The assembly procedure involves storing only the nonzero elements ofthe Jacobianmatrix in the form of a linear array, and the correspondingrow and column locations are stored using an incremental flag. Thesolution is assumed to have converged when the L2 norms of all thenormalized solution variables and residuals are below a chosenconvergence criterion of 10−3.For problem II, the 3-D fluidmodel is solved by a commercial CFD

package,ANSYSFluent. According to Sinha et al.’s experiment [15],a compressible and steady turbulent flow is assumed. For Sinhaet al.’s experiment [15], the Reynolds number based on the holediameter and inlet conditions was 16,100. Our numerical simulationmaintains geometric and kinematic similarity with the experimentin [15] by matching the same Reynolds number (Re � 16100)and blowing ratio (M � 1). This resulted in scaling down theexperimental geometry of [15] by a factor of five to a hole diameter of0.00254 m for our numerical simulation. This allows for lesscomputational mesh and faster solution convergence. The maximumMach number achieved in the flowfield is below 0.3. We employ thedensity-based formulation of the computer code while minimizingcompressibility effects. We interpolate the time-averaged electricforce density as a source term in the gas flow momentum equationsusing the UDF (user defined functions). We use the ideal gasapproximation and theAUSM (advection upstream splittingmethod)solver closed with RNG (renormalized group) κ-ε turbulence modelwith standard wall function. In a previous publication, we modeledturbulence for the baseline case using detached eddy simulation(DES) [12]. These reported results, albeit expensive, were muchcloser to the experimental data. Here, to reduce computational cost,we use κ-ε turbulence model, which is suitable for the steady-stateflow assumption. The Courant number is set equal to unity forsolution control. A second-order upwind discretization method isemployed. The solution convergence is determinedwhen the residualamong the continuity, momentum, energy, turbulent kinetic energy,and turbulent dissipation are less than 10−3. For problem I, bothplasma and fluid simulations are carried out under the samemesh sizeof 92,160 elements. For the simulation, the time step is 10−11 s andthe grid size is 10−5 m, which is sufficiently resolved to capturerelevant sheath physics and definitely well resolved for the flowphysics. The simulation is considered converged when residuals forelectron and ion number densities and the electric potential are below10−3. For problem II, it iswell known that a coarse grid cannot resolvethe effect of the downstream vortices. Problem II is assumed to havesteady flow condition. The simulation is converged when theresiduals are below 10−3. The computational mesh of 200,000 cellsis chosen based on the grid independent study [28] for betterconvergence and less computational cost. We used previous gridresolution studies for problem II only because the fluid thermalinteraction for the film cooling problem is a more involved problem.For problem I, the computational domainwas sufficient to capture thesheath physics and fluid physics. All cases for problem II requireapproximately 1400 iterations for convergence.

IV. Results and Discussion

Two problems are investigated in this paper. As mentioned earlier,problem I focuses on understanding the basic influence of ahorseshoe actuator on the surrounding flow under a near-quiescentcondition (with a freestream velocity of 0.3 m∕s). For problem II, thebaseline case is compared with Sinha et al.’s experimental data [15]and two other numerical works [29,30]. Other cases are scaledwith different levels of plasma force density for improving filmcooling effectiveness. Because we use an inherently time-averagedturbulence model for problem II, the computed results are presentedat the steady state. For a blowing ratioM � 1, the interaction of flowprofiles between the wind tunnel and cold jet inlet is very complex.This is due to the fact that for the range of velocities the boundarylayers are not thin everywhere within the pipe. For very thickboundary layers, the flow close to the wall behaves like a typical

boundary layer, whereas for a very thin boundary layer a wall-jetstructure forms downstreamof the jet exit. Such flowmotion creates abound kidney-shaped vortical structure that stretches downstreamalong the primary flow direction.

A. Problem I

The temperature distribution of the baseline case is shown in Fig. 5.The results show how the hot freestream of 300 K interacts with thecold jet of 150 K at �x; y; z� � �0.0003; 0.0003; 0.0� m. This rangeof temperature is based on the experiment [15]. The attachment of thecold fluid protects the downstream surface from high thermal stressesdue to high temperature. We can roughly define a region where thesurface temperature is less than 230 K. For the case of an outwardplasma force shown in Fig. 6, we impose a dc potential of 50 V to theexposed (previously called inner) electrode on the dielectric surfaceand ground the (previously called outer) electrode inside thedielectric. The gap between the electrodes is equal to 0.00004m. Thistype of dc microplasma has been tested by Wilson et al. [31,32].Such microplasmas have evolved into plasma-enhanced chemicalvapor deposition for microelectromechanical system and integratedcircuit processing. Figure 6a shows the electric force vectorsoverlaid on the flooded contours of charge separation (at the xzplane, y � 0.0003 m) and potential distribution (at the xy plane,z � 0.00003 m). The force is acting outward from poweredelectrode to the grounded electrode in three dimensions. The peak ofcharge separation is ∼1015 m−3. The potential varies from 50 to 0 Vbetween the exposed and the grounded electrode. The force densityfor this electrode arrangement (not shown) is in the order of kN∕m3.We can see such force actuation drastically changes the flow path ofthe cold jet upward as shown in Fig. 6b. From the top viewof theworksurface at z � 0.00003 m, the temperature is above 290 K atdownstream of the coolant hole. To induce an inward plasma force,we apply potential to the outer electrode on thework surface as shownin Fig. 7a. This reduces the cold jet momentum as shown in Fig. 7b.Here, the average temperature at locations downstream of the coolanthole is much lower than the baseline case. Hence, the film coolingeffectiveness has been greatly improved. From previous tests, we cansee the case with an inward plasma force is useful for attaching thecold jet to the work surface and increasing film cooling effectiveness

Fig. 5 Temperature distribution on the xz plane of y � 0.0003 m andon the xy plane of z � 0.00003 m for the baseline case without plasmaforce.

AIAA Early Edition / ROYANDWANG 5

Dow

nloa

ded

by U

NIV

ER

SIT

Y O

F FL

OR

IDA

on

June

5, 2

013

| http

://ar

c.ai

aa.o

rg |

DO

I: 1

0.25

14/1

.T39

45

Page 6: Numerical Investigation of Three-Dimensional Plasma ... · Numerical Investigation of Three-Dimensional Plasma Actuation for Improving Film Cooling Effectiveness Subrata Roy∗ University

on both streamwise and spanwise directions. We explore this furtherfor the film cooling problem II with a realistic blowing ratio.

B. Problem II

Here, we investigate the interaction of a cold jet of 150K issuing atan angle of 35 deg into a freestream gas at 110 m∕s and 300K, and its

influence on the temperature distribution of the plate. To maintain ablowing ratio of unity, the flow speed at the intersection of theinjection duct and the flat plate ranges between 50 to 100 m∕s. At thelocation of x � −3d, the local Reynolds number (Rex) of 320,152is calculated based on the freestream velocity. Correspondingdisturbance thickness is equal to δx � 5 � 17d∕�Rex�0.5 �

Fig. 6 For an outward plasma force, a) the charge q, the potential ϕ and b) the resulting temperature T are plotted.

Fig. 7 For an inward plasma force, a) the charge q, the potential ϕ and b) the resulting temperature T are plotted.

6 AIAA Early Edition / ROYANDWANG

Dow

nloa

ded

by U

NIV

ER

SIT

Y O

F FL

OR

IDA

on

June

5, 2

013

| http

://ar

c.ai

aa.o

rg |

DO

I: 1

0.25

14/1

.T39

45

Page 7: Numerical Investigation of Three-Dimensional Plasma ... · Numerical Investigation of Three-Dimensional Plasma Actuation for Improving Film Cooling Effectiveness Subrata Roy∗ University

0.00038 m, the momentum thickness is equal to θx � 0.133δx �0.00005 m, and the momentum-thickness Reynolds number isReθ � 376. At x � −d (upstream of the hole), Reθ � 1027. Foreffectively controlling such a high momentum flow, we need toscale the plasma force density from kN∕m3 to MN∕m3. We havedemonstrated the feasibility of similar force density scaling in arecent publication on microscale plasma actuators [33]. It isimportant to note that the curved actuators employed here generatefully 3-D vortices [34–36] with a large range of frequencies makingthem particularly suitable for actuating the hairpin structures within aturbulent flow. Figure 8a plots the temperature distribution on thevertical midplane (y � 0), whereas Fig. 8b shows the temperaturedistribution on the horizontalwork surface (z � 0). Altogether, sevenfilm cooling cases are simulated with force density varied from aninitial zero (no force) to a maximum of 8 MN∕m3. It is obvious thatthe liftoff effect causes a significant reduction in film coolingeffectiveness for the baseline case shown in Fig. 8a and 8b where theforce density (i) No force. As we increase the force density, the flow

completely attaches to the work surface. Importantly, such actuationapplied in a 3-D manner demonstrates successful spreading of thecold film over the downstream surface not only in the streamwisedirection but also in the spanwise fashion. The force density increasehas a significant influence on the cold flow attachment justdownstream of the coolant hole (see Fig. 8b). The effectiveness isplotted in Fig. 9 against a nondimensional ratio of x∕Md, where x isthe downstream distance,M is the blowing ratio, and d is the circularpipe diameter. The computed centerline effectiveness results for thebaseline case (with no actuation) compare reasonably with theexperiment of Sinha et al. [15] and two other previously reportednumerical results [29,30] as shown in Fig. 9a. We can see thecenterline effectiveness decreases for the baseline case as the distanceof downstream (x∕d) increases due to the liftoff effect. The resultpredicted by our model is similar to two other numerical predictions[29,30]. In Fig. 9b, as the force density increases to the maximum,the centerline effectiveness increases by over 100% than thebaseline case.

Fig. 8 Temperature contour with different force density for the plane at a) y � 0 and b) z � 0.

Fig. 9 Comparison of centerline effectiveness for a) the baseline case and b) different plasma force densities.

AIAA Early Edition / ROYANDWANG 7

Dow

nloa

ded

by U

NIV

ER

SIT

Y O

F FL

OR

IDA

on

June

5, 2

013

| http

://ar

c.ai

aa.o

rg |

DO

I: 1

0.25

14/1

.T39

45

Page 8: Numerical Investigation of Three-Dimensional Plasma ... · Numerical Investigation of Three-Dimensional Plasma Actuation for Improving Film Cooling Effectiveness Subrata Roy∗ University

V. Conclusions

The contribution of this numerical work is to successfully applyfirst principles based plasma force to enhance film coolingeffectiveness. We solved the plasma governing equations using afinite element based MIG flow code to predict the induced plasmaforce and used that body force in the Navier–Stokes equationsemploying a finite volume based commercial ANSYS Fluentsoftware. Two problems were investigated using horseshoe shapedplasma actuators. For problem I, we tested three different cases withvery low speed bulk (0.3 m∕s) and coolant (0.42 m∕s) flows to find ahigher film cooling effectiveness on the work surface. Based on thetemperature distribution, the electrode arrangement for an inwardplasma force predicts better jet attachment to the work surfacedownstream of the coolant hole. The predicted force density of thehorseshoe actuator in this case was ∼kN∕m3, which required a fewwatts of power for the surface area considered. In an actual gasturbine (blowing ratio∼1, problem II), a force density ofMN∕m3wasrequired for an effective flow control. Such a high force density wasdeemed viable due to the recent development ofmicroscale actuators.Aswevaried the electric force density from0 (no force) to 8 MN∕m3,we found significant improvements for both streamwise andspanwise film cooling effectiveness in comparison to the baselinecase. For the maximum force density, the improvement of centerlineeffectiveness was about 260% than the baseline case at a downstreamlocation of x � 10d. The baseline case was in good agreement withreported experimental data and other numerical work. Simulationresults indicate that plasma augmented flow control ideas maybecome more beneficial for energy budget management in film-cooling applications especially for cases with largely separated jets athigher blowing ratios.

Acknowledgments

This work was partially supported by the Air Force Office ofScientific ResearchGrantsmonitored byDouglas Smith. The authorsalso acknowledge partial support from the Florida Center forAdvanced Aero-Propulsion for this research.

References

[1] Haven, B. A., and Kurosaka, M., “Kidney and Anti-Kidney Vortices inCrossflow Jets,” Journal of Fluid Mechanics, Vol. 352, Dec. 1997,pp. 27–64.doi:10.1017/S0022112097007271

[2] Roy, S., “Numerical Investigation of the Blade Cooling Effect byMultiple Jets Issuing at an Angle,” Numerical Heat Transfer, Vol. 38,No. 7, 2000, pp. 701–718.doi:10.1080/10407780050195652

[3] Walters, D. K., and Leylek, J. H., “ADetailed Analysis of Film CoolingPhysics: Part I—Streamwise Injection with Cylindrical Holes,” Journalof Turbomachinery, Vol. 122, No. 1, 2000, pp. 102–112.doi:10.1115/1.555433

[4] Hyams, D. G., and Leylek, J. H., “ADetailed Analysis of Film CoolingPhysics: Part III—Streamwise Injection with ShapedHoles,” Journal ofTurbomachinery, Vol. 122, No. 1, 2000, pp. 122–132.doi:10.1115/1.555435

[5] Azzi, A., and Jubran, B. A., “Numerical Modeling of Film CoolingFrom Converging Slot-Hole,” International Journal of Heat and Mass

Transfer, Vol. 43, No. 4, 2007, pp. 381–388.doi:10.1007/s00231-006-0115-9

[6] Zhang, X. Y., and Hassan, I. G., “Film Cooling Effectiveness of anAdvanced-Louver Cooling Scheme for Gas Turbine,” Journal of

Thermophysics and Heat Transfer, Vol. 20, No. 4, 2006, pp. 754–763.doi:10.2514/1.18898

[7] Na, S., and Shih, T. I. P., “Increasing Adiabatic Film-CoolingEffectiveness by Using an Upstream Ramp,” Journal of Heat Transfer,Vol. 129, No. 4, 2007, pp. 464–471.doi:10.1115/1.2709965

[8] Garg, V. K., “Heat Transfer on a Film-Cooled Rotating Blade,”International Journal of Heat and Fluid Flow, Vol. 21, No. 2, 2000,pp. 134–145.doi:10.1016/S0142-727X(99)00072-7

[9] Heidmann, J. D., Rigby, D. L., andAmeri, A. A., “AThree-DimensionalCoupled Internal/External Simulation of a Film-Cooled Turbine Vane,”

Journal of Turbomachinery, Vol. 122, No. 2, 2000, pp. 348–359.doi:10.1115/1.555450

[10] Wilcox, D. C., “Re-Assessment of the Scale-Determining Equation forAdvanced Turbulence Models,” AIAA Journal, Vol. 26, No. 11, 1988,pp. 1299–1310.doi:10.2514/3.10041

[11] Zhong, F., and Brown, G. L., “A 3-Dimensional, Coupled, DNS, HeatTransfer Model and Solution for Multi-Hole Cooling,” International

Journal of Heat and Mass Transfer, Vol. 50, Nos. 7–8, 2007,pp. 1328–1343.doi:10.1016/j.ijheatmasstransfer.2006.09.017

[12] Kapadia, S., Roy, S., and Heidmann, J. D., “First Hybrid TurbulenceModeling for Turbine Blade Cooling,” Journal of Thermophysics andHeat Transfer, Vol. 18, No. 1, 2004, pp. 154–156.doi:10.2514/1.2824

[13] Martini, P., Schulz, A., and Bauer, H. T., “Detached Eddy Simulationof Film Cooling Performance on the Trailing Edge Cutback of GasTurbine Airfoils,” Journal of Turbomachinery, Vol. 128, No. 2, 2006,pp. 292–299.doi:10.1115/1.2137739

[14] Kim, S. I., andHassan, I. G., “UnsteadyHeat TransferAnalysis of a FilmCooling Flow,” 46th AIAA Aerospace Sciences Meeting and Exhibit,American Institute of Aeronautics and Astronautics Inc., Reston, VA,AIAA Paper 2008-1287, Jan. 2008, pp. 1–12.

[15] Sinha, A. K., Bogard, D. G., and Crawford, M. E., “Film-CoolingEffectiveness Downstream of a Single Row of Holes with VariableDensity Ratio,” Journal of Turbomachinery, Vol. 113, No. 3, 1991,pp. 442–449.doi:10.1115/1.2927894

[16] Bell, C. M., Hamakawa, H., and Ligrani, P. M., “Film Cooling fromShaped Holes,” Journal of Heat Transfer, Vol. 122, No. 2, 2000,pp. 224–232.doi:10.1115/1.521484

[17] Bunker, R. S., “A Review of Shaped Hole Turbine Film-CoolingTechnology,” Journal of Heat Transfer, Vol. 127, No. 4, 2005,pp. 441–453.doi:10.1115/1.1860562

[18] Ekkad, S. V., Ou, S., and Rivir, R. B., “Effect of Jet Pulsationand Duty Cycle on Film Cooling from a Single Jet on a LeadingEdge Model,” Journal of Turbomachinery, Vol. 128, No. 3, 2006,pp. 564–571.doi:10.1115/1.2185122

[19] Bogard, D. G., and Thole, K. A., “Gas Turbine Film Cooling,” Journalof Propulsion and Power, Vol. 22, No. 2, 2006, pp. 249–270.doi:10.2514/1.18034

[20] Moreau, E., “Airflow Control by Non-Thermal Plasma Actuators,”Journal of Physics D: Applied Physics, Vol. 40, No. 3, 2007,pp. 605–636.doi:10.1088/0022-3727/40/3/S01

[21] Corke, T. C., Enloe, C. L., and Wilkinson, S. P., “Dielectric BarrierDischarge Plasma Actuators for Flow Control,” Annual Review of Fluid

Mechanics, Vol. 42, No. 1, 2010, pp. 505–529.doi:10.1146/annurev-fluid-121108-145550

[22] Roy, S., and Wang, C. C., “Plasma Actuated Heat Transfer,” Applied

Physics Letters, Vol. 92, No. 23, 2008, pp. 231501–231501-3.doi:10.1063/1.2938886

[23] Wang, C. C., and Roy, S., “Electrodynamic Enhancement of FilmCooling of TurbineBlades,” Journal of Applied Physics, Vol. 104, 2008,Paper 073305.doi:10.1063/1.2990074

[24] Gregory, J. W., Enloe, C. L., Font, G. I., and McLaughlin, T. E., “ForceProduction Mechanisms of a Dielectric-Barrier Discharge PlasmaActuator,” 45th AIAA Aerospace Sciences Meeting and Exhibit,American Institute of Aeronautics and Astronautics Inc., Reston, VA,AIAA Paper 2007-185, Jan. 2007, pp. 2191–2203.

[25] Kumar, H., and Roy, S., “Multidimensional Hydrodynamic Plasma-Wall Model for Collisional Plasma Discharges with and WithoutMagnetic Field Effects,” Physics of Plasmas, Vol. 12, No. 9, 2005,pp. 093508–093508-10.doi:10.1063/1.2044747

[26] Surzhikov, S. T., and Shang, J. S., “Two-Component Plasma Model forTwo-Dimensional Glow Discharge in Magnetic Field,” Journal of

Computational Physics, Vol. 199, No. 2, 2004, pp. 437–464.doi:10.1016/j.jcp.2004.02.019

[27] Hagelaar, G. J. M., and Pitchford, L. C., “Solving the BoltzmannEquation to Obtain Electron Transport Coefficients and RateCoefficients for Fluid Models,” Plasma Sources Science and

Technology, Vol. 14, No. 4, 2005, pp. 722–733.doi:10.1088/0963-0252/14/4/011

8 AIAA Early Edition / ROYANDWANG

Dow

nloa

ded

by U

NIV

ER

SIT

Y O

F FL

OR

IDA

on

June

5, 2

013

| http

://ar

c.ai

aa.o

rg |

DO

I: 1

0.25

14/1

.T39

45

Page 9: Numerical Investigation of Three-Dimensional Plasma ... · Numerical Investigation of Three-Dimensional Plasma Actuation for Improving Film Cooling Effectiveness Subrata Roy∗ University

[28] Zhang, X. Z., and Hassan, I., “Film Cooling Effectiveness of anAdvanced-Louver Cooling Scheme for Gas Turbine,” Journal of

Thermophysics and Heat Transfer, Vol. 20, No. 4, 2006, pp. 754–764.doi:10.2514/1.18898

[29] Immarigeon, A. A., “Advanced Impingement/Film-Cooling Schemesfor High-Temperature Gas Turbines: Numerical Study,” M.S. Thesis,Dept. of Mechanical and Industrial Engineering, Concordia Univ.,Montreal, 2004.

[30] Berhe,M. K., and Patankar, S. V., “ANumerical Study of Discrete-HoleFilm Cooling,” American Society of Mechanical Engineers, Paper 96-WA/HT-8, 1996.

[31] Wilson, C. G., Gianchandani, Y. B., Arslanbekov, R. R., Kolobov, V.,and Wendt, A. E., “Profiling and Modeling of DC NitrogenMicroplasmas,” Journal of Applied Physics, Vol. 94, No. 5, 2003,pp. 2845–2851.doi:10.1063/1.1595143

[32] Wilson,C.G., andGianchandani,Y.B., “SelectiveDeposition of Siliconat RoomTemperature Using DCMicroplasmas,” IEEE Transactions on

Plasma Science, Vol. 35, No. 3, 2007, pp. 573–577.doi:10.1109/TPS.2007.897412

[33] Zito, J., Durscher, R., Soni, J., Roy, S., and Arnold, D., “Flow and ForceInducement Using Micro Size Dielectric Barrier Discharge Actuators,”Applied Physics Letters, Vol. 100, No. 19, 2012, Paper 193502.doi:10.1063/1.4712068

[34] Roy, S., andWang, C. C., “Bulk FlowModification with Horseshoe andSerpentine Plasma Actuators,” Journal of Physics D: Applied Physics,Vol. 42, No. 3, 2009, Paper 032004.doi:10.1088/0022-3727/42/3/032004

[35] Rizzetta, D. P., and Visbal, M. R., “Large-Eddy Simulation of Plasma-Based Turbulent Boundary-Layer Separation Control,” AIAA Journal,Vol. 48, No. 12, 2010, pp. 2793–2810.doi:10.2514/1.J050014

[36] Durscher, R., and Roy, S., “Three-Dimensional Flow MeasurementsInduced fromSerpentine PlasmaActuators inQuiescentAir,” Journal ofPhysics D: Applied Physics, Vol. 45, No. 3, 2012, Paper 035202.doi:10.1088/0022-3727/45/3/035202