Nuclear Wallet Cards and ENSDF compatibility Alejandro Sonzogni National Nuclear Data Center
-
Upload
hayes-chase -
Category
Documents
-
view
25 -
download
4
description
Transcript of Nuclear Wallet Cards and ENSDF compatibility Alejandro Sonzogni National Nuclear Data Center
Alejandro Sonzogni NSDD 2007
Nuclear Wallet Cards and ENSDF compatibility
Alejandro Sonzogni
National Nuclear Data CenterBrookhaven National Laboratory
E-mail: [email protected]
Brookhaven Science Associates
2Alejandro Sonzogni NSDD 2007
NWC-ENSDF Compatibility
Nuclear Wallet Cards
1) Major updates every 5 years
2) Minor updates at least once a year
ENSDF
1) Continuous updates
2) Can be out of synch with Wallet Cards in half-life, J, isomer energy and decay modes.
NuDat provides both NWC and ENSDF values, which can be confusing to users.
3Alejandro Sonzogni NSDD 2007
NWC-ENSDF Compatibility
Example 1:
147Xe, exists in NWC but not in ENSDF.
Example 2:
146Xe has T1/2 and decay modes in NWC but the ENSDF file (10 years old, 1 level) has only incomplete decay mode.
Example 3:
108Ag isomer, NWC has more recent T1/2. Changing the ENSDF T1/2 will require running LOGFT and checking for J arguments.
Received many e-mails recently on this issue
4Alejandro Sonzogni NSDD 2007
NWC-ENSDF Compatibility
Proposed action:
1) Check for NWC-ENSDF compatibility a few times a year in levels energy, T1/2, J and decay modes.
2) If NWC values are more up to date:
2.1) Communicate with ENSDF evaluator.
2.2) For cases where NO LOGFT/ALPHAD/RULER calculations are involved, (examples 1 and 2) the NNDC will perform the update with the original evaluator’s consent.
2.3) For more complex cases, original evaluator will be expected to perform changes within a few months. If evaluator is not available, the NNDC will do it. The NNDC may perform the update if the original evaluator so wishes.