NSW Forensic Pathology & Coroners Court€¦ · the principal under the terms of the contract. any...

6
MAIN AVENUE STAFF PARKING (87) PUBLIC & POLICE PARKING (71) EXISTING BUILDING FFL RL 35.85 BOH (12) OUTLINE OF 8 X 12M CONTAINERS BTU ENTRY BTU EXIT CORONERS PARKING ENTRY DISCRETE EXIT MAIN PUBLIC ENTRY STAFF TRAFFIC IN/OUT DROP OFF ZONE TWO WAY TRAFFIC PUBLIC TRAFFIC IN / OUT SUB STATION KIOSK SECURE ROAD 2400 HIGH TIMBER SECURITY FENCING 2400 HIGH SECURITY FENCING - PALISADE SECURITY FENCING - CHAIN MESH - HEIGHT TO MATCH EXISTING PEDESTRIAN GATE STANDBY GENERATOR VEHICLE GATE CULVERT 15080 105815 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 S-3 2 S-1 S-2 S-4 S-5 S-6 S-7 S-8 S-9 S-10 S-11 S-12 S-13 S-14 S-15 S-16 S-17 S-19 S-20 S-21 S-22 S-23 S-24 S-25 S-26 S-27 S-28 S-29 S-30 S-31 S-32 S-33 S-34 S-35 S-36 S-37 S-38 S-39 S-41 S-42 S-43 S-44 S-45 S-46 S-47 S-48 S-49 S-50 S-51 S-52 S-53 S-54 S-55 S-56 S-57 S-58 S-59 S-60 S-61 S-63 S-64 S-65 S-66 S-67 S-68 S-69 S-70 S-71 S-72 S-73 S-74 S-75 S-76 S-77 S-78 S-79 S-80 S-81 S-82 S-83 S-84 S-85 S-86 S-87 S-18 S-62 S-40 JOSEPH STREET B-22 B-23 B-21 B-20 B-19 B-18 B-17 B-16 B-15 B-14 B-13 B-12 B-11 B-10 B-9 B-8 B-7 B-24 WEEROONA ROAD B-4 B-3 B-2 B-6 B-5 FUNERAL & POLICE (12) BOH ENTRY STAFF ENTRY RL 38.61 RL 37.46 RL 36.42 BOOSTER VALVES & WATER METER BICYCLE PARKING ENTRY RL 35.83 GATE BOH YARD 18810 25605 10590 SLIDING VEHICLE GATE PEDESTRIAN GATE PEDESTRIAN PATH RL 36.92 RL 35.85 BOOM GATE RL 37.25 11000 10050 EXISTING FENCE FORECOURT PEDESTRIAN PATH SECURE ACCESS POINT BOUNDARY AS PART OF PROPOSED LOT ACQUISITION EXISTING FENCE EXISTING FENCE EXISTING FENCE EXISTING FENCE EXISTING GATE HOUSE EXISTING PEDESTRIAN PATH EXI ST I N G PED E ST R I AN PAT H EXISTING SANDSTONE WALL WITH 'BOTANICA' SIGNAGE PEDESTRIAN PATH BOOM GATE REJECTED VEHICLE TURNING BAY EXISTING DRIVEWAY EXISTING TREE TO BE ASSESSED BY ARBORIST 11780 OVERFLOW AREA FOR DVI OPERATION IF REQUIRED - PARKING MANAGEMENT TO BE IMPLEMENTED 16910 BOOM GATE DROP OFF ZONE LINE OF EXISTING CROSS OVER IMPACT RESISTANT POWER BOLLARDS TO ELECTRICAL ENGINEER'S DETAILS POWER BOLLARD POWER BOLLARD POWER BOLLARD POWER BOLLARD RL 35.75 RL 35.75 RL 35.43 20965 53660 4320 37000 14800 16015 POWER BOLLARD LOT 1 DP850697 LOT 21 DP1158586 LOT 24 DP1158586 LOT 22 DP1158586 LOT 79 DP1097193 LOT 82 DP1139415 1:14 1:14 EXISTING CARPARKING EXISTING ROAD NEW KEY LOCK ACCESS GATE IN EXISTING FENCE MAINTENANCE VEHICLE ACCESS RAMP / STAIR ACCESS TO BE ADVISED BY CARDNO SWIPE ACCESS GATE NEW PATH CONNECTING TO F.A.S.S. FACILITY TO BE CONFIRMED ON SITE RL 36.70 SWIPE ACCESS GATE RL 35.75 RL 36.85 B-1 GATE FOR MAINTENANCE VEHICLE ACCESS 2400 HIGH SECURITY FENCING - PALISADE WITH PERFORATED METAL SCREEN 2400 HIGH SECURITY FENCING - PALISADE WITH PERFORATED METAL SCREEN 2400 HIGH SECURITY FENCING - PALISADE 2400 HIGH SECURITY FENCING - PALISADE LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING LIGHTING UPLIGHT UPLIGHT BIKE PARKING MODIFY EXISTING FENCE AS REQUIRED FOR NEW CONNECTION TO F.A.S.S FACILITY - TO BE CONFIRMED ON SITE RL 36.97 RL 35.60 RL 36.43 RL 36.88 RL 37.33 RL 35.83 N ARCHITECTS CLIENT CHECKED DATE DRAWING No REVISION SCALE PROJECT No DRAWN BY PROJECT KEY PLAN DRAWING TITLE ABN: 73 561 269 057 PH: (02) 8299 4600 FAX: (02) 8299 4646 LEVEL 4, 89 YORK ST, SYDNEY, 2000 AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSION SILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057 THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF COPYRIGHT ALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCED OR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OF THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS OR IMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTED TO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. DIMENSIONS USE FIGURED DIMENSIONS, DO NOT SCALE . CONTRACTORS MUST VERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANY WORK OR MAKING ANY SHOP DRAWING WHICH MUST BE SUBMITTED AND REVIEWED BEFORE MANUFACTURE. FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONS THE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASIS OF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THE DESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATES SPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHERE APPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDING FIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OR EQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIOR TO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULE AND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITY FOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOT BEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS. THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYED FROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FOR INFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THE SERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARE CORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THE ACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERING DOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THE INTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERING SYSTEMS. SERVICE POINTS DISCLAIMER ISSUE FOR TENDER PROJECT MANAGER PH: (02) 9267 9599 FAX: (02) 9264 5844 LEVEL 6, 155 CLARENCE ST, SYDNEY, 2000 130276-HI-AR-DWG- As indicated@A0 10 C:\Users\mlan\Documents\FPCC_BUILDING_A16_CENTRAL_mlan.rvt NSW Forensic Pathology & Coroners Court 17/08/16 ML BR 10249 1010 Corner of Joseph St and Main Av Lidcombe NSW 2141 LOCATION AND SITE PLAN 1 : 500 2200 2 SITE PLAN 1 : NTS 1 LOCATION PLAN REV DESCRIPTION DRN DATE 1 ISSUED FOR INFORMATION ML 17.08.16 2 PROGRESS ISSUE ML 17.08.16 3 ISSUED FOR INFORMATION ML 18.08.16 4 PROGRESS ISSUE CG 09.09.16 5 PROGRESS ISSUE CG 14.10.16 6 ISSUE FOR DRAFT DD BR 11.11.16 7 ISSUE FOR DD BR 28.11.16 8 WORK IN PROGRESS ISSUE BR 13.12.16 9 ISSUE FOR PRE TENDER BR 16.12.16 10 ISSUE FOR TENDER - NOT FOR CONSTRUCTION BR 20.01.17

Transcript of NSW Forensic Pathology & Coroners Court€¦ · the principal under the terms of the contract. any...

Page 1: NSW Forensic Pathology & Coroners Court€¦ · the principal under the terms of the contract. any licence, ... mortuary manager office 2p - sen. tech post mortem bay 1 post mortem

MAIN AVENUE

STAFF PARKING (87) PUBLIC & POLICE PARKING

(71)

EXISTING BUILDING

FFL RL 35.85

BOH (12)

OUTLINE OF 8 X 12M CONTAINERS

BTU ENTRY BTU EXIT

CORONERS PARKINGENTRY

DISCRETEEXIT

MAIN PUBLIC ENTRY

STAFF TRAFFICIN/OUT

DROP OFFZONE

TWO WAYTRAFFIC

PUBLIC TRAFFIC IN / OUT

SUB STATIONKIOSK

SECURE ROAD

2400 HIGH TIMBER SECURITY FENCING

2400 HIGH SECURITY FENCING - PALISADESECURITY FENCING - CHAIN MESH - HEIGHT TO MATCH EXISTING

PEDESTRIANGATE

STANDBYGENERATOR

VEHICLE GATE

CULVERT

15080105815

1

3

4

5

6

7

8

9

10

11

12

13

14

15

16

33

32

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

34

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

71

70

69

68

67

66

65

64

63

62

61

60

59

58

57

56

55

54

53

52

51

S-3

2

S-1

S-2

S-4

S-5

S-6

S-7

S-8

S-9

S-10

S-11

S-12

S-13

S-14

S-15

S-16

S-17

S-19

S-20

S-21

S-22

S-23

S-24

S-25

S-26

S-27

S-28

S-29

S-30

S-31

S-32

S-33

S-34

S-35

S-36

S-37

S-38

S-39

S-41

S-42

S-43

S-44

S-45

S-46

S-47

S-48

S-49

S-50

S-51

S-52

S-53

S-54

S-55

S-56

S-57

S-58

S-59

S-60

S-61

S-63

S-64

S-65

S-66

S-67

S-68

S-69

S-70

S-71

S-72

S-73

S-74

S-75

S-76

S-77

S-78

S-79

S-80

S-81

S-82

S-83

S-84

S-85

S-86

S-87

S-18

S-62

S-40

JOSEPH STREET

B-22 B-23B-21B-20B-19B-18B-17B-16B-15B-14B-13B-12B-11B-10B-9B-8B-7

B-24

WEEROONA ROAD

B-4B-3B-2 B-6B-5

FUNERAL & POLICE(12)

BOH ENTRY

STAFF ENTRY

RL 38.61

RL 37.46RL 36.42

BOOSTER VALVES& WATER METER

BICYCLE PARKINGENTRY

RL 35.83

GATE

BOH YARD

18810

25605

10590

SLIDING VEHICLE GATE

PEDESTRIANGATE

PEDESTRIAN PATH

RL 36.92RL 35.85

BOOM GATE

RL 37.25

11000 10050

EXISTING FENCE

FORECOURT

PEDESTRIAN

PATH

SECUREACCESS

POINT

BOUNDARY AS PART OF PROPOSED LOT ACQUISITION

EXISTING FENCE

EXISTING FENCE

EXISTING FENC E

EXISTING FENCE

EXISTINGGATE HOUSE

EXISTI NG PEDESTRIAN PATH

EXISTING PEDESTRIAN PATH

EXISTING SANDSTONE WALLWITH 'BOTANICA' SIGNAGE

PEDESTRIAN PATH

BOOM GATE

REJECTED VEHICLETURNING BAY

EXISTING DRIVEWAY

EXISTING TREE TOBE ASSESSED BY

ARBORIST

11780

OVERFLOW AREA FOR DVIOPERATION IF REQUIRED -PARKING MANAGEMENT TOBE IMPLEMENTED

16910

BOOM GATE

DROP OFFZONE

LINE OF EXISTINGCROSS OVER

IMPACT RESISTANT POWERBOLLARDS TO ELECTRICALENGINEER'S DETAILS

POWERBOLLARD

POWERBOLLARD

POWERBOLLARD

POWERBOLLARD

RL 35.75

RL 35.75

RL 35.43

20965 53660 4320 37000

14800

16015

POWERBOLLARD

LOT 1DP850697

LOT 21DP1158586

LOT 24DP1158586

LOT 22DP1158586

LOT 79DP1097193

LOT 82DP1139415

1:14

1:14

EXISTING CARPARKING

EXISTING ROAD

NEW KEY LOCK ACCESS GATEIN EXISTING FENCE

MAINTENANCE VEHICLEACCESS

RAMP / STAIR ACCESS TO BEADVISED BY CARDNO

SWIPE ACCESS GATE

NEW PATHCONNECTING TOF.A.S.S. FACILITY TOBE CONFIRMED ONSITE

RL 36.70

SWIPEACCESSGATE

RL 35.75

RL 36.85

B-1

GATE FORMAINTENANCEVEHICLE ACCESS

2400 HIGH SECURITY FENCING - PALISADE WITH PERFORATED METAL SCREEN

2400 HIGH SECURITYFENCING - PALISADEWITH PERFORATEDMETAL SCREEN

2400

HIG

H SE

CURI

TY F

ENCI

NG -

PALIS

ADE

2400

HIG

H SE

CURI

TY F

ENCI

NG -

PALIS

ADE

LIGHTING

LIGHTING

LIGHTING

LIGHTING

LIGHTING

LIGHTING

LIGHTING

LIGHTING

LIGHTING

LIGHTING

LIGHTING LIGHTING LIGHTING

UPLIGHTUPLIGHT

BIKE PARKING MODIFY EXISTINGFENCE AS REQUIREDFOR NEWCONNECTION TOF.A.S.S FACILITY - TOBE CONFIRMED ONSITE

RL 36.97

RL 35.60

RL 36.43 RL 36.88 RL 37.33RL 35.83

N

ARCHITECTS

CLIENT

CHECKEDDATE

DRAWING No REVISION

SCALE

PROJECT No

DRAWN BY

PROJECT

KEY PLAN

DRAWING TITLE

ABN: 73 561 269 057

PH: (02) 8299 4600 FAX: (02) 8299 4646LEVEL 4, 89 YORK ST, SYDNEY, 2000

AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSIONSILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057

THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF

COPYRIGHTALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCEDOR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC ORMECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OFTHE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS ORIMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTEDTO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPALUNDER THE TERMS OF THE CONTRACT.

DIMENSIONSUSE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUSTVERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANYWORK OR MAKING ANY SHOP DRAWING WHICH MUST BESUBMITTED AND REVIEWED BEFORE MANUFACTURE.FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS

SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONSTHE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASISOF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THEDESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATESSPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHEREAPPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDINGFIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OREQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIORTO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULEAND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITYFOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOTBEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.

THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYEDFROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FORINFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THESERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARECORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THEACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERINGDOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THEINTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERINGSYSTEMS.

SERVICE POINTS DISCLAIMER

ISSUE FOR TENDER

PROJECT MANAGER

PH: (02) 9267 9599 FAX: (02) 9264 5844LEVEL 6, 155 CLARENCE ST, SYDNEY, 2000

130276-HI-AR-DWG-

Asindicated@A0

10

C:\U

s ers

\mla

n\D

ocum

ent s

\FP

CC

_BU

ILD

ING

_A16

_CEN

TRAL

_mla

n.rv

t

NSW Forensic Pathology &Coroners Court

17/08/16 ML BR

10249 1010

Corner of Joseph St and Main AvLidcombe NSW 2141

LOCATION AND SITE PLAN 1 : 50022002 SITE PLAN

1 : NTS

1 LOCATION PLAN

REV DESCRIPTION DRN DATE1 ISSUED FOR INFORMATION ML 17.08.162 PROGRESS ISSUE ML 17.08.163 ISSUED FOR INFORMATION ML 18.08.164 PROGRESS ISSUE CG 09.09.165 PROGRESS ISSUE CG 14.10.166 ISSUE FOR DRAFT DD BR 11.11.167 ISSUE FOR DD BR 28.11.168 WORK IN PROGRESS ISSUE BR 13.12.169 ISSUE FOR PRE TENDER BR 16.12.1610 ISSUE FOR TENDER - NOT FOR CONSTRUCTION BR 20.01.17

Page 2: NSW Forensic Pathology & Coroners Court€¦ · the principal under the terms of the contract. any licence, ... mortuary manager office 2p - sen. tech post mortem bay 1 post mortem

(c) 2016 Transoft Solutions, Inc. All rights reserved.

(c) 2016 Transoft Solutions, I nc. All rights r eserved.

(c) 2016 Transoft Solutions, Inc. All rights reserved.

(c) 2016 Transof t Soluti ons, Inc. Al l rights reserved.

SD-015

2

1 2 5 6

A

B

C

D

E

F

G

I

J

K

L

M

3 4 7

H

32222

32222

1B2220

COUNSELL INTRM

COUNSELL INTRM

COUNSELL INTRM

COUNSELL INTRM

CAFÉ

STORE -FIREARM

SACREDSPACE (MULTI

FAITH)

DISCRETEWAIT - MEDIUM

DISCRETEWAIT RM

DISCRETEWAIT RM

ANTE RM AANTE RM BANTE RM C

VIEWING RM C VIEWING RM B VIEWING RM A

FAMILY RM

SHERIFFSTORE

WAITING -MAIN

WC ST ACC

8500

5925

9485

7705

7705

1000

010

000

1000

050

4086

0086

0086

00

COUNSELLINGWAITING

VIEWINGCOUNSELLING

EMERGENCY EXIT

M CHNG RM ST

OFFICE 1P -MORTUARYMANAGER

OFFICE 2P -SEN. TECH

POST MORTEMBAY 1

POST MORTEMBAY 3

POST MORTEMBAY 5

POST MORTEMBAY 7

POST MORTEMBAY 9

POST MORTEMBAY 11

POST MORTEMBAY 12

POST MORTEMBAY 10

POST MORTEMBAY 8

POST MORTEMBAY 6

POST MORTEMBAY 4

POST MORTEMBAY 2

STAFFSTATION RM COLLABORATION

RM

BAY - MOBILEX-RAY

TEACHINGSUITE -

VIEWING

TEACHINGSUITE -

AUTOPSYBODY PREP

WC ST UNISEX- PM

WC ST UNISEX- PM

CLNR

STORE -SECURE BONE

DECOMPOSEPM ROOM

TISSUERETRIEVAL

FORMALINDECANTING

BAY - MOBEQUIP

BODY STORE 1BODY STORE 2

STORE -CONSUMABLES

BONEPROCESS

F CHNG RM ST

CUT UP RM

STORE -SPECIMENS

STAFFKITCHENETTE

STORE - DVI

STORE -GEN/CONS

WEIGHSTATION

BODYTRANSFER

BODYTRANSFER

OFFICE -MORTUARY

RECEPCLERKS

ADMI

N KIOS

K

HBS/S

POLICEBREAK-OUT

RMW'ST - POLICE

BEV'B (OPENPLAN)

OFFICE 1P - FM

CLINICALWASTE

STORE -P'COPY /

STATIONERY /SCAN

STORE -MAINTENANCE

STOREFORKLIFT

LOADINGDOCK - CLEAN

DIRTY HOLD /BIN HOLDING

BAY

BIN WASH

LOADINGDOCK - DIRTY

CAMPUS DISTRM

FILE SERVERRM UPS RM

MAIN SWITCHRM

CORONERSPARKING

POT WATERRM

GAS METERRM

CARRIER RM

FIRESPRINKLER &HYDRANT RM

MORTUARY

BODY TRANSFER UNIT

BOH

CORONERSENTRY

HB S/S

PMCOURTYARD

DG STORE

CAMPUS DISTRM 2

WC

WASH UP

COMPRESSEDAIR PLANT

BAY - MAIL

RECEPTION

BAY - BEV(OPEN PLAN)

ISOLATIONROOM

HOMICIDE PMSUITE

HOMICIDE PMSUITE

ADMISSIONSAREA

COLLAB RM

COLLAB RM

HB

HB

BAY - MORTTROLLEY

HB

WATER FTN

EMG SHR &EYE

W'ST - PCKIOSK

WC

MRI RM

CT SCANNER

CT CNTL RM

MRI CNTL RM

BAY - MRITROLLEY

WATER FTN

PARENTINGROOM

WC ACC/BABY

WC PUB F

WC PUB M

COURTYARD -SACREDSPACE

COURTYARD -RELATIVES

CLNR

WC ST

PPE'B

PPE'B

EMG SHR &EYE

EMG SHR &EYE

LINE OF BUILDING OVER

RECEPTIONSTORE

ABLUTIONS

COURTYARD -RELATIVES

COURTYARD -RELATIVES

SEARCH RM

LINE OF CANOPY OVER

EDB

EDB

STAIR 2

STAIR 3

STAIR 4

MJ

FRIDGE

SHARPENINGSTATION

BAY - BEV

BICYCLEPARKING

RL 35.85

RL 35.85

RL 35.85

RL 35.85

RL 35.85

RL 35.85

RL 35.85

RL 35.83

RL 35.83

RL 35.83

MRICOMPUTER

RM

LIFT LOBBY STAFF ENTRY

MRI TROLLEYPARK

OBSE

RVAT

IONGA

LLER

Y

BOH YARD

PARKING -FUNERAL,

POLICE & BOH(24 SPACES)

SECUREENTRANCE

ENTRYAIRLOCK

MAIN LOBBY

W'ST - HOTDESK

PPE'B

HB

BAY -VENDING

FIP

2201

1

2201

2

2200 1

2200 2

PUBLIC ENTRY

2B2221

2A2221

22031

22032

FIRESPRINKLER

ALARM VALVERM

RL 36.03

RL 35.85

RL 35.85

ODONTOLOGYRM

GUN ROOM

22103 1

2

4

22107

6

5

8

2210

14

13

16

15

2210 9

10

11

12

ANTEROOM

STORE -BLOCK &

SLIDE

BAY -

HELM

ETS

1:10

1:10

FORENSICSSTORE

PPE'B

COUNSELLINGHOT DESK

WC ST

52222

52222

1A2220

42222

42222

CLNR

BODY STORE -FREEZER

LAUNDRY

BAY -TROLLEY

OBSE

RVAT

IONGA

LLER

Y

CLEANERSSTORES

STAIR 5

CORR

IDOR

GUMBOOTSTORE

BAY - BOOTWASH

BAY - BOOTWASH

BAY - TOOLBOX

BAY - TOOLBOX

GUMBOOTSTORE

CORR

IDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORR

IDOR

CORR

IDOR CT HOLD

CORR

IDOR

CORR

IDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

CORR

IDOR

CORRIDOR

CORRIDOR

CAFE DECK

LINE OF CANOPY OVER

RL 35.85

EXTE

RNAL

FEN

CE LI

NE

560 24480 6966

?

BOH YARD

6009842 26043 16416

500

7061

510

LINE

OF B

UILD

ING

OVER

EXTERNAL FENCE LINE

560

1001

6022

4613

30

9000 9670 7390 9130 8780 8330560

52300725

3576

8200

2346

060

190

8310

FHR /

FH

FHR /

FH

FHR

FHR / FH

FHR /

PFE

FHR

FHR / FH

FHR

FHR /

FH

FHR / FH

FHR / FH

PFE

PPE'B

CORRIDOR

CORRIDOR

FHR

BAY - LINEN

BAY - LINEN

CORRIDOR

TEACHINGSUITE ENTRY

RL 35.83 RL 35.83

GARDEN BED

GARDEN BED

GARDEN BED

EXTERNAL FENCE LINE

EXTERNAL FENCE LINE

EXTE

RNAL

FEN

CE LI

NE

FHR / FH

LIFT 1

LIFT 2

LIFT 3 LIFT 4

TITLE

BOUN

DARY

TITLE BOUNDARY

TITLE BOUNDARY

TITLE BOUNDARY

B-2 B-3 B-4 B-5 B-6 B-7 B-8 B-9 B-10 B-11 B-12 B-13 B-14 B-15 B-16 B-17 B-18 B-19 B-20 B-21

PARKING -STAFF (87SPACES)

S-15

S-14

S-13

S-12

S-11

S-10

S-9

S-8

S-7

S-6

S-5

PARKING -PUBLIC (71SPACES)

RL 35.75

RL 36.42

RL 35.75

RL 35.75

JOSE

PH ST

FORECOURT

STAIR 1

221017

RL 35.75

RL 35.85

RL 36.43 RL 36.88

RL 37.33

RAMP UP 1:14 RAMP UP 1:14 RAMP UP 1:14

SD-015

2

1 2 5 6

A

B

C

D

E

F

G

I

J

K

L

M

3 4 7

H

32222

32222

1B2220

2201

1

2201

2

2200 1

2200 2

2B2221

2A2221

22022

22031

22032

52222

52222

1A2220

42222

42222

9000 9670 7390 9130 8780 8330

8500

5925

9485

7705

7705

1000

010

000

1000

050

4086

0086

0086

00

LIFT PIT

LIFT PIT

OUTL

INE OF

BUILD

ING OV

ER

OUTL

INE OF

BUILD

ING OV

ER

OUTLINE OF BUILDING OVER

OUTLINE OF BUILDING OVER

OUTLINE OF BUILDING OVER

STAIR 3

STAIR 4

RL 33.13

RL 33.82

OUTL

INE OF

BUILD

ING OV

ER

SUBF

LOOR

WAL

L

D.01

D.01

REFER TO STRUCTURALENGINEER'S DRAWINGS FOR

FOOTING DETAILS

LIFT 1

LIFT 2

LIFT 3 LIFT 4

RL 34.35

RL 34.45

SUBFLOOR WALL

SUBF

LOOR

WAL

L

RETA

INING

WAL

L

SUBFLOOR WALL

TITLE BOUNDARY

TITLE BOUNDARY

TITLE BOUNDARY

EXTE

RNAL

FENC

E LINE

SUBF

LOOR

WAL

L

SUBFLOOR WALL

LAND

SCAP

ING W

ALL

INDICATIVE LINE OF BATTER.REFER TO CIVIL ENGINEER'SDETAIL

REFER TO LANDSCAPEARCHITECT'S DRAWINGS FOR

LANDSCAPING DETAILS

RL 33.03

RL 33.72

TITLE

BOUN

DARY

5215

5

RL 35.56BULK EXCAVATION LEVEL(REFER CIVIL ENGINEER'S

DOCUMENTATION)

RL 35.43BULK EXCAVATION LEVEL

(INDICATIVE OUTLINE ONLY- REFER CIVIL ENGINEER'S

DOCUMENTATION)

RL 35.385BULK EXCAVATION LEVEL

(INDICATIVE OUTLINE ONLY -REFER CIVIL ENGINEER'S

DOCUMENTATION)

RL 35.43BULK EXCAVATION LEVEL

(INDICATIVE OUTLINE ONLY- REFER CIVIL ENGINEER'S

DOCUMENTATION)

LEGEND

PROPOSED RELATIVE SPOT LEVEL (METRES) ABOVE DATUM.RL XX.XX

GENERAL NOTES:

• COLUMNS ARE CENTRED ON GRID INTERSECTIONS U.N.O.

XXXXXX

SECTION REFERENCEDETAIL NUMBERREFERENCE SHEET NUMBER

ABBREVIATIONS:

AP ACCESS PANELCH CEILING HEIGHTCJ CONTROL JOINTDP DOWNPIPEDWG DRAWINGSFH FIRE HYDRANTFHR FIRE HOSE REELFIP FIRE INDICATOR PANELFW FLOOR WASTEHYD HYDRAULICMJ MOVEMENT JOINTMS MILD STEELNOM NOMINALOF OVERFLOWRWH RAINWATER HEADRWO RAINWATER OUTLETSC STEEL COLUMNST STEEL STUDS/S STAINLESS STEELTBA TO BE ADVISEDTOH TOP OF HOBTOP TOP OF PARAPETTOW TOP OF WALLWPM WATER PROOF MEMBRANE

1000

GENERAL DESIGNDIMENSIONSDIMENSION TO GRIDS 737

GRID GRID

XXXX

ELEVATION REFERENCEDETAIL NUMBER

REFERENCE SHEET NUMBER

X

2HR FIRE WALL

N

ARCHITECTS

CLIENT

CHECKEDDATE

DRAWING No REVISION

SCALE

PROJECT No

DRAWN BY

PROJECT

KEY PLAN

DRAWING TITLE

ABN: 73 561 269 057

PH: (02) 8299 4600 FAX: (02) 8299 4646LEVEL 4, 89 YORK ST, SYDNEY, 2000

AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSIONSILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057

THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF

COPYRIGHTALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCEDOR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC ORMECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OFTHE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS ORIMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTEDTO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPALUNDER THE TERMS OF THE CONTRACT.

DIMENSIONSUSE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUSTVERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANYWORK OR MAKING ANY SHOP DRAWING WHICH MUST BESUBMITTED AND REVIEWED BEFORE MANUFACTURE.FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS

SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONSTHE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASISOF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THEDESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATESSPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHEREAPPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDINGFIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OREQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIORTO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULEAND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITYFOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOTBEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.

THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYEDFROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FORINFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THESERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARECORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THEACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERINGDOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THEINTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERINGSYSTEMS.

SERVICE POINTS DISCLAIMER

ISSUE FOR TENDER

PROJECT MANAGER

PH: (02) 9267 9599 FAX: (02) 9264 5844LEVEL 6, 155 CLARENCE ST, SYDNEY, 2000

130276-HI-AR-DWG-

Asindicated@A0

11

C:\U

s ers

\mla

n\D

ocum

ent s

\FP

CC

_BU

ILD

ING

_A16

_CEN

TRAL

_mla

n.rv

t

NSW Forensic Pathology &Coroners Court

01/08/16 ML BR

10249 2000

Corner of Joseph St and Main AvLidcombe NSW 2141

OVERALL FLOOR PLAN - LEVEL B & 00

1 : 20022002 Level 00 - Overall floor plan

1 : 20022001 Level B - Overall floor plan

REV DESCRIPTION DRN DATE1 ISSUED FOR DD UG2.4 - MORTUARY ML 15.07.162 ISSUED FOR DD UG2.6 - MORTUARY KW 22.07.163 ISSUED FOR DD UG2.7 - MORTUARY ML 01.08.164 PROGRESS ISSUE ML 17.08.165 PROGRESS ISSUE CG 09.09.166 PROGRESS ISSUE CG 14.10.167 ISSUE FOR DRAFT DD BR 11.11.168 ISSUE FOR DD BR 28.11.169 WORK IN PROGRESS ISSUE BR 13.12.1610 ISSUE FOR PRE TENDER BR 16.12.1611 ISSUE FOR TENDER - NOT FOR CONSTRUCTION BR 20.01.17

Page 3: NSW Forensic Pathology & Coroners Court€¦ · the principal under the terms of the contract. any licence, ... mortuary manager office 2p - sen. tech post mortem bay 1 post mortem

UP

UP

UPUP

UP

UP

1 2 5 6

A

B

C

D

E

F

G

3 4 7

-50 SD

-150 SD

-150 SD

-150 SD

-150 SD

RL 34.35

LIFT PIT

-50 SD -50 SD

-150 SD

SET DOWN TOBE CONFIRMED

-150 SD

-150 SD

-50 SD

CAST IN SS GRATE DRAIN

CAST IN SS GRATE DRAIN

CAST IN SS GRATE DRAIN

CAST IN SS GRATE DRAIN

REVOLVING DOOR REBATETO DETAIL

EXPANSION JOINT - SIZE TBC BY STRUC. ENG.

EXPANSION JOINT - SIZE TBC BY STRUC. ENG.

-320 SD

-150 SD

-150 SD

CAST IN SS GRATE DRAINCAST IN SS GRATE DRAIN

FALL FALL

FALL FALL FALL

-150 SD

1:14 1:16

100mm X 30mm EXPANSIONJOINT REBATE

100mm X 30mm EXPANSION JOINT REBATE100mm X 30mm EXPANSION

JOINT REBATE

RL 35.83

RL 35.83

RL 36.17

FALL

SET DOWN IN SWITCH ROOM(IF REQUIRED) TO BE CONFIRMED

-50 SD

-150 SD

-50 SD

CAST IN SS GRATE DRAIN

FALL

FALL

FW

FW

FW

FW

FW

FW

FW

FWFW

FWFW

FW FW

-150 SD

FW

FW

-150 SD

FW

FW

CONCRETE HOB

FW

FW

HYDRST 1 HYDR ST 2

HYDRST 4

RWO RWO

RWO

RWO

CAST IN SS GRATE DRAIN

FALL

FW

CAST IN SS GRATE DRAIN

FW FW FW FW FW FW FW FW

BOOTW

BOOTW

SIZE & LOCATION OFCONCRETE DUCTCULVERT TBC ALONGWITH TABLE DESIGN

SIZE & LOCATION OFCONCRETE DUCTCULVERT TBC ALONGWITH TABLE DESIGN

SIZE & LOCATION OFCONCRETE DUCTCULVERT TBC ALONGWITH TABLE DESIGN

SIZE & LOCATION OFCONCRETE DUCT CULVERTTBC ALONG WITH TABLEDESIGN

SIZE & LOCATION OFCONCRETE DUCT CULVERTTBC ALONG WITH TABLEDESIGN

SIZE & LOCATION OFCONCRETE DUCT CULVERTTBC ALONG WITH TABLEDESIGN

SIZE & LOCATION OF CONCRETEDUCT CULVERT TBC ALONG WITHTABLE DESIGN

STAIR 4

-50 SD

-50 SD

HYDRST 3

RL 36.00

1:61:6

FW

FW

FW

ESFB

FWG

FWG

FWG

FWG

FWG

FWG

FWG

FWG

FWG

FWG

CAST IN SS GRATE DRAIN

FWG

FWG

CAST IN SS GRATE DRAIN

CAST IN SS GRATE DRAIN

300

30

FW

-75 SD-75 SD-75 SD-75 SD-75 SD

-75 SD

SIZE & LOCATION OFCONCRETE DUCT CULVERTTBC ALONG WITH TABLEDESIGN

SIZE & LOCATION OFCONCRETE DUCT CULVERTTBC ALONG WITH TABLEDESIGN

SIZE & LOCATION OFCONCRETE DUCTCULVERT TBC ALONGWITH TABLE DESIGN

SIZE & LOCATION OFCONCRETE DUCTCULVERT TBCALONG WITH TABLEDESIGN

FWG

9000 9670 7390 9130 8780 8330

1000

010

000

5040

8600

8600

8600

ALLOW FORBUILD UP

ALLOW FORBUILD UP

ALLOW FORBUILD UP

RL 35.80

-50 SD

FALL

ALLOW FOR BUILD UP

-50 SD

-50 SD

RL 35.80

REFER TO DWG-2053 FOR CONTINUATION

2423

3208

6064 8330 290

2423

214 7390 5211150

347

4630

3640

720

1900

1100 5681 1709

1653 1068 4669

5024

86

6527

80

4586150

368 4534150

400

5690

300

5040

1000

011

90

300

5040

1000

071

0

6170

3152

1823

2315

510

697

5845

2310

1142

1813

2385

450

7312

64

180 5665

2475 1290

CL

2245

C L

1110

C L663

CL2244

5245

214

2225 1540

C L21

91C L

3143

940

2850

150 3910

150 3910

2850

1190

RL 35.85

CL

2191

642

540

1503613 369

C LC L

1950

1502104 500

150

1400

5004150

C LC L

1040

2374

150

379

5810

-50 SD

ALLOW FOR BUILD UP FOR CARPETINSET TO BE FLUSH WITH TILES

RL 35.84

CL

1726 C L

2306

RL 35.84

RL 35.84

RL 35.84

ALLOW FOR BUILDUP FOR CARPETINSET TO BE FLUSHWITH TILES

ALLOW FOR BUILDUP FOR CARPETINSET TO BE FLUSHWITH TILES

IN-FLOOR TRENCH TO MAIN SWITCH ROOM.REFER TO ELECTRICAL ENGINEER'S DETAILS.

C LC L

2187

2400

CLCLCL2072 3157 4820 4635

C LC L

2417

2170

C LC L

2417

2170

1841

9450

2486

250

CL218

CL1748

330

300 2471

3532 3368

ALLOW FOR ENTRANCE MAT TOBE FLUSH WITH FLOOR FINISH

RL 35.83

ALLOW FOR ENTRANCE MAT TO BEFLUSH WITH FLOOR FINISH RL 35.83

RL 35.83

ALLOW FOR ENTRANCEMAT TO BE FLUSH WITHFLOOR FINISH

2195 195

800

3150

1825

647 2995 102

2538

500

64 736 2408

4144

3226

3536

550

885 1000

ALLOW NOM. -50SETDOWN FORPIVOT DOORFLOOR SPRING

FWG

DUCT UNDER SLAB DUCT UNDER SLAB

DUCT UNDER SLAB DUCT UNDER SLAB

DUCT UNDER SLAB DUCT UNDER SLAB

DUCT UNDER SLAB DUCT UNDER SLAB

DUCT UNDER SLAB DUCT UNDER SLAB

DUCT UNDERSLAB

RWO

RWO

-150 SD

693 407

C L

1997

CL715 CL

1480

C L

1260

2365 212

214 336 5164

663

648

4708

1436

CLEQ EQ

3368

5731

1723

5245

214

5387 369

3422 384

C L31

54

C L

3203CL

4354

3988

4499

1076 1076 1076 1094 1050 1076 1077 36301762

4244 1820

RL 35.85

RL 35.85

RL 35.85 RL 35.85

RL 35.85

RL 35.85

RL 35.85

RL 35.85

RL 35.85

RL 35.85

RL 35.85

RL 35.85

RL 35.83

ALLOW FOR ENTRANCE MAT TOBE FLUSH WITH FLOOR FINISH

800

1100

REFER TO HYDRAULIC, CIVIL ANDLANDSCAPING DOCUMENTATION FORDRAINAGE REQUIREMENTS TOCOURTYARDS.

REFER TO HYDRAULIC, CIVIL ANDLANDSCAPING DOCUMENTATION FORDRAINAGE REQUIREMENTS TOCOURTYARDS..

-50mm SET DOWN

-100mm SET DOWN

-150mm SET DOWN

-320mm SET DOWN

PENETRATIONS FORMECHANICAL DUCTWORK

N

ARCHITECTS

CLIENT

CHECKEDDATE

DRAWING No REVISION

SCALE

PROJECT No

DRAWN BY

PROJECT

KEY PLAN

DRAWING TITLE

ABN: 73 561 269 057

PH: (02) 8299 4600 FAX: (02) 8299 4646LEVEL 4, 89 YORK ST, SYDNEY, 2000

AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSIONSILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057

THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF

COPYRIGHTALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCEDOR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC ORMECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OFTHE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS ORIMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTEDTO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPALUNDER THE TERMS OF THE CONTRACT.

DIMENSIONSUSE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUSTVERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANYWORK OR MAKING ANY SHOP DRAWING WHICH MUST BESUBMITTED AND REVIEWED BEFORE MANUFACTURE.FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS

SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONSTHE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASISOF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THEDESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATESSPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHEREAPPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDINGFIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OREQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIORTO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULEAND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITYFOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOTBEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.

THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYEDFROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FORINFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THESERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARECORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THEACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERINGDOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THEINTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERINGSYSTEMS.

SERVICE POINTS DISCLAIMER

ISSUE FOR TENDER

PROJECT MANAGER

PH: (02) 9267 9599 FAX: (02) 9264 5844LEVEL 6, 155 CLARENCE ST, SYDNEY, 2000

130276-HI-AR-DWG-

1 : 100@A0

6

C:\U

s ers

\mla

n\D

ocum

ent s

\FP

CC

_BU

ILD

ING

_A16

_CEN

TRAL

_mla

n.rv

t

NSW Forensic Pathology &Coroners Court

10/08/16 KW BR

10249 2052

Corner of Joseph St and Main AvLidcombe NSW 2141

LEVEL 00 - SLAB SET OUT PLAN -ZONE 1

REV DESCRIPTION DRN DATE1 PROGRESS ISSUE ML 17.08.162 PROGRESS ISSUE CG 09.09.163 PROGRESS ISSUE CG 14.10.164 WORK IN PROGRESS ISSUE BR 13.12.165 ISSUE FOR PRE TENDER BR 16.12.166 ISSUE FOR TENDER - NOT FOR CONSTRUCTION BR 20.01.17

Page 4: NSW Forensic Pathology & Coroners Court€¦ · the principal under the terms of the contract. any licence, ... mortuary manager office 2p - sen. tech post mortem bay 1 post mortem

UP

UP

1 2 5 6

I

J

K

L

M

3 4 7

H

-150 SD

-150 SD

RL 34.45LIFT PIT

SET DOWN TO BE CONFIRMED

SET DOWN TO BE CONFIRMED

SET DOWN TOBE CONFIRMED

-100 SD

-150 SD

RL 36.03

1:14RL 36.03

-50 SD

CAST IN SS GRATE DRAIN

RECESSED WEIGHSTATION

EXPANSION JOINT - SIZE TBC BY STRUC. ENG.

EXPANSION JOINT - SIZE TBC BY STRUC. ENG.EXPANSION JOINT - SIZE TBC BY STRUC. ENG.

CAST IN SS GRATE DRAIN CAST IN SS GRATE DRAIN

CAST IN SS GRATE DRAIN CAST IN SS GRATE DRAIN

CAST IN SS GRATE DRAIN

-320 SD

CAST IN SS GRATE DRAIN

MRI SET DOWN

FALL FALL FALL

-50 SD

-100 SD

-150 SD

-100 SD

CT SCANNER TRENCHTO BE CONFIRMED.SUBJECT TO EXTERNALCONSULTANT'S ADVICE.

100mm X 50mmEXPANSION JOINT REBATE

-50 SD

-50 SD

-150 SD

-150 SD

RL 36.03

-150 SD

CAST IN SS GRATE DRAIN

CAST IN SS GRATE DRAIN

FW

FW

FW

FW

FW

FW

FW

FW

FW FW

FWFW

FWFW

CAST IN SS GRATE DRAIN

SET DOWN TO BE CONFIRMED

CAST IN SS GRATE DRAIN

-150 SD

FW

FW

-150 SD

FALL

FALL

FW

FALL FALL FALL FALL

FALLFA

LL

FW

FW FW FW

FALL

NOTE: VENTILATIONDUCT UNDER FLOOR

RWO

BUNDED COMPACTUS ZONE

FALL

FWG

CAST IN SS GRATE DRAIN

-50 SD

FW

PIT SET DOWN AND BUNDINGFOR FORMALIN TANKS

CAST IN SS GRATE DRAIN

CAST IN SS GRATE DRAIN

CAST IN SS GRATE DRAIN

-100 SD

FALL

BOOTW

BOOTW

SIZE & LOCATION OFCONCRETE DUCT CULVERTTBC ALONG WITH TABLEDESIGN

BOOTW

SIZE & LOCATION OF CONCRETEDUCT CULVERT TBC ALONG WITHTABLE DESIGN

SIZE & LOCATION OF CONCRETEDUCT CULVERT TBC ALONG WITHTABLE DESIGN

STAIR 3

STAIR 2

HYDR ST 6

HYDR ST

MRI TRENCH TO BE CONFIRMED.SUBJECT TO EXTERNALCONSULTANT'S ADVICE.

FW FW

FW

-50 SD

-150 SD

-150 SD

FWG

FWG

FWG

FW

FW

FWG

FW

FW

FW

BOOTW

100mm X 50mmEXPANSION JOINT REBATE

100mm X 50mmEXPANSION JOINT REBATE

SIZE & LOCATION OFCONCRETE DUCT CULVERTTBC ALONG WITH TABLEDESIGN

SIZE & LOCATION OFCONCRETE DUCTCULVERT TBC ALONGWITH TABLE DESIGN

REMOVABLE SCREED OVER SET DOWN - REFER STRUCTURAL SLAB SET OUT PLANS

FWG

FWG

8500

5925

9485

7705

7705

ALLOW FORBUILD UP

-150 SD -150 SD

RL 35.80

RL 36.03

RL 35.83

REFER TO DWG-2052 FOR CONTINUATION

9000 9670 7390 9130 8780 8330

5955 330 150

2046

3485

4840 3490

609

992

7390 9130

1730 6155 1730

150

4644

7705

6153

150

500 2452

996

2225

300 2805 2827 3368

3710

3082

7390 6110 3020 384

3614100

1563100

434 3404

6064 8330 290

6676

6132

3353

398150

6128 60 6314

5981

610

150347

214

2046

1713

5932 3570

218

211

CL

2247 C L

715

C L

715

CL4519

CL

784C L47

90

CL

2848C L10

20

CL

1968

CL

2832

C L

1525

CL1537

C L16

95C L

2436

2394 7390 2216

1042

150

CL

1476

1580

150 49

4

C L69

8

CL1571

CL

1571

C LC L

1664

270 7390 3175

CLEQ EQ

CLEQ EQ

CLEQ EQ

1506760

150825

1506760

150

CLEQ EQ

CLEQ EQ

CLEQ EQ

275 3153 100 1530 100 2233 3923 100 1530 100 3153 325

C LC L

C L

6050

6050

C L

1010

300

3002179

3968

C LC L

1022

2166

CL1038

491150

398 150

CLCLCL2569 2215 2217 1933

150

363

FW

CL5970

C L

2132

CL

1276

2810

211

3769

147 8630

30 270

ALLOW FOR BUILD UP FORENTRANCE MAT TO BE FLUSHWITH TILES

RL 35.83

RL 35.85

RL 36.03

RL 35.83

RL 35.83

ALLOW FOR ENTRANCE MAT TOBE FLUSH WITH FLOOR FINISH

ALLOW FOR ENTRANCE MAT TOBE FLUSH WITH FLOOR FINISH

DUCT UNDER SLAB

DUCT UNDER SLAB DUCT UNDER SLAB

DUCT UNDER SLAB DUCT UNDER SLAB

DUCT UNDERSLAB

DUCT UNDERSLAB

FALL

FALL

CAST IN SS GRATE DRAIN1:200

3422 384

4244 1820

2640

1857

CL

2132C L12

70

2755

2065

2671

2089

2140

616

C L14

54

205 2848 2285

1429

1534

154

4945

2046

3042

330

C L16

18

C L

1618

CL2329

278

30

4023

190

110 1418

CL858

CL

858

785

1315

21 1130

245 8687

4116

1454

1746

550

C L

2719

160

6059

3266

2755

2918

3725

330 5400

870

CL

3100

CL3100

C LC L

1156

2034

180 6194

368 5084CL

1320C L

1889

CL4410

C L

380

RL 35.85

RL 35.85

RL 35.85

RL 35.85

RL 35.85

RL 35.85

RL 35.85

-50mm SET DOWN

-100mm SET DOWN

-150mm SET DOWN

-320mm SET DOWN

PENETRATIONS FORMECHANICAL DUCTWORK

N

ARCHITECTS

CLIENT

CHECKEDDATE

DRAWING No REVISION

SCALE

PROJECT No

DRAWN BY

PROJECT

KEY PLAN

DRAWING TITLE

ABN: 73 561 269 057

PH: (02) 8299 4600 FAX: (02) 8299 4646LEVEL 4, 89 YORK ST, SYDNEY, 2000

AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSIONSILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057

THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF

COPYRIGHTALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCEDOR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC ORMECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OFTHE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS ORIMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTEDTO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPALUNDER THE TERMS OF THE CONTRACT.

DIMENSIONSUSE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUSTVERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANYWORK OR MAKING ANY SHOP DRAWING WHICH MUST BESUBMITTED AND REVIEWED BEFORE MANUFACTURE.FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS

SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONSTHE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASISOF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THEDESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATESSPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHEREAPPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDINGFIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OREQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIORTO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULEAND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITYFOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOTBEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.

THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYEDFROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FORINFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THESERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARECORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THEACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERINGDOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THEINTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERINGSYSTEMS.

SERVICE POINTS DISCLAIMER

ISSUE FOR TENDER

PROJECT MANAGER

PH: (02) 9267 9599 FAX: (02) 9264 5844LEVEL 6, 155 CLARENCE ST, SYDNEY, 2000

130276-HI-AR-DWG-

1 : 100@A0

6

C:\U

s ers

\mla

n\D

ocum

ent s

\FP

CC

_BU

ILD

ING

_A16

_CEN

TRAL

_mla

n.rv

t

NSW Forensic Pathology &Coroners Court

10/08/16 KW BR

10249 2053

Corner of Joseph St and Main AvLidcombe NSW 2141

LEVEL 00 - SLAB SET OUT PLAN -ZONE 2

REV DESCRIPTION DRN DATE1 PROGRESS ISSUE ML 17.08.162 PROGRESS ISSUE CG 09.09.163 PROGRESS ISSUE CG 14.10.164 WORK IN PROGRESS ISSUE BR 13.12.165 ISSUE FOR PRE TENDER BR 16.12.166 ISSUE FOR TENDER - NOT FOR CONSTRUCTION BR 20.01.17

Page 5: NSW Forensic Pathology & Coroners Court€¦ · the principal under the terms of the contract. any licence, ... mortuary manager office 2p - sen. tech post mortem bay 1 post mortem

1 2 5 6

I

J

K

L

M

3 4 7

H

RL 34.45

STAIR 3

RL 33.13

8500

5925

9485

7705

7705

9000 9670 7390 9130 8780 8330

REFER TO DWG-2050 FOR CONTINUATION

INDICATIVE LINE OF BATTER.REFER TO CIVIL ENGINEER'SDETAIL

4750 500

2855

30

LIFT 3 LIFT 4RL 35.385

BULK EXCAVATION LEVEL(INDICATIVE OUTLINE ONLY -

REFER CIVIL ENGINEER'SDOCUMENTATION)

RL 35.56BULK EXCAVATION LEVEL(REFER CIVIL ENGINEER'S

DOCUMENTATION)

-50mm SET DOWN

-100mm SET DOWN

-150mm SET DOWN

-320mm SET DOWN

PENETRATIONS FORMECHANICAL DUCTWORK

N

ARCHITECTS

CLIENT

CHECKEDDATE

DRAWING No REVISION

SCALE

PROJECT No

DRAWN BY

PROJECT

KEY PLAN

DRAWING TITLE

ABN: 73 561 269 057

PH: (02) 8299 4600 FAX: (02) 8299 4646LEVEL 4, 89 YORK ST, SYDNEY, 2000

AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSIONSILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057

THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF

COPYRIGHTALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCEDOR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC ORMECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OFTHE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS ORIMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTEDTO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPALUNDER THE TERMS OF THE CONTRACT.

DIMENSIONSUSE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUSTVERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANYWORK OR MAKING ANY SHOP DRAWING WHICH MUST BESUBMITTED AND REVIEWED BEFORE MANUFACTURE.FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS

SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONSTHE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASISOF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THEDESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATESSPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHEREAPPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDINGFIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OREQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIORTO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULEAND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITYFOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOTBEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.

THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYEDFROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FORINFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THESERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARECORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THEACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERINGDOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THEINTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERINGSYSTEMS.

SERVICE POINTS DISCLAIMER

ISSUE FOR TENDER

PROJECT MANAGER

PH: (02) 9267 9599 FAX: (02) 9264 5844LEVEL 6, 155 CLARENCE ST, SYDNEY, 2000

130276-HI-AR-DWG-

1 : 100@A0

6

C:\U

s ers

\mla

n\D

ocum

ent s

\FP

CC

_BU

ILD

ING

_A16

_CEN

TRAL

_mla

n.rv

t

NSW Forensic Pathology &Coroners Court

18/11/16 KW BR

10249 2051

Corner of Joseph St and Main AvLidcombe NSW 2141

LEVEL B - SLAB SET OUT PLAN - ZONE2

REV DESCRIPTION DRN DATE1 PROGRESS ISSUE ML 17.08.162 PROGRESS ISSUE CG 09.09.163 PROGRESS ISSUE CG 14.10.164 WORK IN PROGRESS ISSUE BR 13.12.165 ISSUE FOR PRE TENDER BR 16.12.166 ISSUE FOR TENDER - NOT FOR CONSTRUCTION BR 20.01.17

Page 6: NSW Forensic Pathology & Coroners Court€¦ · the principal under the terms of the contract. any licence, ... mortuary manager office 2p - sen. tech post mortem bay 1 post mortem

1 2 5 6

A

B

C

D

E

F

G

3 4 7

RL 34.35

STAIR 4

RL 33.82

9000 9670 7390 9130 8780 8330

1000

010

000

5040

8600

8600

8600

REFER TO DWG-2051 FOR CONTINUATION

INDICATIVE LINE OF BATTER.REFER TO CIVIL ENGINEER'SDETAIL

4750 1850

1030

2960

LIFT 1

LIFT 2

RL 35.56BULK EXCAVATION LEVEL(REFER CIVIL ENGINEER'S

DOCUMENTATION)

RL 35.43BULK EXCAVATION LEVEL

(INDICATIVE OUTLINE ONLY- REFER CIVIL ENGINEER'S

DOCUMENTATION)

RL 35.43BULK EXCAVATION LEVEL

(INDICATIVE OUTLINE ONLY- REFER CIVIL ENGINEER'S

DOCUMENTATION)

RL 35.385BULK EXCAVATION LEVEL

(INDICATIVE OUTLINE ONLY -REFER CIVIL ENGINEER'S

DOCUMENTATION)

-50mm SET DOWN

-100mm SET DOWN

-150mm SET DOWN

-320mm SET DOWN

PENETRATIONS FORMECHANICAL DUCTWORK

N

ARCHITECTS

CLIENT

CHECKEDDATE

DRAWING No REVISION

SCALE

PROJECT No

DRAWN BY

PROJECT

KEY PLAN

DRAWING TITLE

ABN: 73 561 269 057

PH: (02) 8299 4600 FAX: (02) 8299 4646LEVEL 4, 89 YORK ST, SYDNEY, 2000

AND SHALL NOT BE REPRODUCED WITHOUT THEIR WRITTEN PERMISSIONSILVER THOMAS HANLEY (VIC) PTY LTD ABN 73 561 269 057

THIS ARCHITECTURAL DESIGN IS THE COPYRIGHT OF

COPYRIGHTALL RIGHTS RESERVED. THIS WORK IS COPYRIGHT AND CANNOT BE REPRODUCEDOR COPIED IN ANY FORM OR BY ANY MEANS (GRAPHIC, ELECTRONIC ORMECHANICAL, INCLUDING PHOTOCOPYING) WITHOUT THE WRITTEN PERMISSION OFTHE PRINCIPAL UNDER THE TERMS OF THE CONTRACT. ANY LICENCE, EXPRESS ORIMPLIED, TO USE THE DOCUMENT FOR ANY PURPOSE WHATSOEVER IS RESTRICTEDTO THE TERMS OF THE AGREEMENT OR IMPLIED AGREEMENT WITH THE PRINCIPALUNDER THE TERMS OF THE CONTRACT.

DIMENSIONSUSE FIGURED DIMENSIONS, DO NOT SCALE. CONTRACTORS MUSTVERIFY ALL DIMENSIONS ON THE SITE BEFORE COMMENCING ANYWORK OR MAKING ANY SHOP DRAWING WHICH MUST BESUBMITTED AND REVIEWED BEFORE MANUFACTURE.FIXTURES, FITTINGS & EQUIPMENT SPECIFICATIONS

SUBSTITUTE FF&E EQUIPMENT SPECIFICATIONSTHE FIT-OUT DESIGN AND DOCUMENTATION HAS BEEN COMPLETED ON THE BASISOF FF&E AND EQUIPMENT ADVISED TO THIS OFFICE AT THE TIME OF BRIEFING THEDESIGN. THE DESIGN PROVISIONS FOR FF&E AND EQUIPMENT INCORPORATESSPATIAL ALLOCATIONS, SERVICING, LOADING AND ACCESS CLEARANCES AND WHEREAPPROPRIATE SERVICES REQUIREMENTS, HAVING DUE REGARD FOR SURROUNDINGFIXTURES AND FITTINGS. IT SHOULD BE NOTED THAT SUBSTITUTE FF&E OREQUIPMENT WITH ALTERNATE SPECIFICATIONS SHOULD NOT BE PROCURED PRIORTO VALIDATING THOSE SPECIFICATIONS AGAINST THE ITEM CONTROL SCHEDULEAND DESIGN PROVISIONS IN THE MODEL. THIS OFFICE ACCEPTS NO RESPONSIBILITYFOR THE PROCUREMENT OF SUBSTITUTE FF&E AND EQUIPMENT WHICH HAS NOTBEEN REVIEWED AND VALIDATED AGAINST THE ORIGINAL DESIGN PROVISIONS.

THE SERVICE POINTS IDENTIFIED ON THESE DRAWINGS HAVE BEEN OVERLAYEDFROM THE BUILDING SERVICES ENGINEERING MODEL, AND ARE PROVIDED FORINFORMATION AND SET-OUT PURPOSES ONLY. WE HAVE BEEN ADVISED BY THESERVICES ENGINEERS THAT THE POINTS REPRESENTED ON THESE DRAWINGS ARECORRECT AT THE TIME OF PUBLICATION. THIS OFFICE DOES NOT WARRANT THEACCURACY OF THIS DATA. REFER TO THE BUILDING SERVICES ENGINEERINGDOCUMENTATION FOR THE INSTALLATION OF THE SERVICES POINTS, AND THEINTERFACE BETWEEN THE SERVICES POINTS AND THE RESPECTIVE ENGINEERINGSYSTEMS.

SERVICE POINTS DISCLAIMER

ISSUE FOR TENDER

PROJECT MANAGER

PH: (02) 9267 9599 FAX: (02) 9264 5844LEVEL 6, 155 CLARENCE ST, SYDNEY, 2000

130276-HI-AR-DWG-

1 : 100@A0

3

C:\U

s ers

\mla

n\D

ocum

ent s

\FP

CC

_BU

ILD

ING

_A16

_CEN

TRAL

_mla

n.rv

t

NSW Forensic Pathology &Coroners Court

18/11/16 KW BR

10249 2050

Corner of Joseph St and Main AvLidcombe NSW 2141

LEVEL B - SLAB SET OUT PLAN - ZONE1

REV DESCRIPTION DRN DATE1 WORK IN PROGRESS ISSUE BR 13.12.162 ISSUE FOR PRE TENDER BR 16.12.163 ISSUE FOR TENDER - NOT FOR CONSTRUCTION BR 20.01.17