Comprehensive unified storage solutions withhigh-end features across the product family: NX4,NS-120, NS-480

Meeting the information-sharingchallengeThe Celerra unified product NS-120 is a dedicatednetwork server optimized for file and block access,delivering high-end features in a scalable, easy-to-use package.

Celerra unified storage systems deliver a single-boxblock and file solution offering a centralized pointof management for distributed environments. Thisenables you to dynamically grow, share, and cost-effectively manage multi-protocol file systems as wellas providing multi-protocol block access. Takeadvantage of simultaneous support for NFS and CIFSprotocols by letting Windows and Linux/UNIX clientsshare files using the DART (Data Access in RealTime) operating system’s sophisticated file-lockingmechanisms. Leverage iSCSI for Tier 2 blockapplications and even native Fibre Channel for high-bandwidth or latency-sensitive applications.

Celerra’s unified product offerings are ideal for thegrowing server virtualization space. Whether customerslook to VMware®, Microsoft Hyper-V™, or Xen-basedserver solutions, Celerra is fully certified for allsupported protocols to ensure successful deploymentsof virtualized infrastructures through all phases ofimplementation.

The advanced functionality features included with theCelerra unified storage platforms enable consolidationof file servers, direct-attached application storage,and even mission-critical block storage requirements,resulting in lower total cost of ownership (TCO) ofyour server and storage assets.

Flexible solutions to meet a widerange of requirementsCelerra unified storage platforms combine an IPstorage enclosure with integrated storage providingNAS, iSCSI, and Fibre Channel in a single packagedsolution. This approach offers the lowest acquisitioncost along with simple implementation and managementwithout sacrificing configurability options.

• Multi-protocol—NAS, (CIFS and NFS including NFSv4.1with pNFS support) connectivity

• Native Block Option for EMC CLARiiON® Fibre Channeland iSCSI connectivity

• One to two X-Blade configurations• Fibre Channel and ATA drive support• Block and file I/O, or combine the two with Celerra

MPFS for high-performance data-sharing applications• Performance/availability mode

Celerra unified storage platformsystem elementsThe Celerra unified storage platform is comprised ofone or more autonomous servers called X-Blades and astorage processor enclosure (SPE). The X-Bladescontrol data movement from the disks to the network.Each X-Blade houses two Intel processors and runsEMC’s DART operating system, designed and optimizedfor high-performance, multi-protocol network file andblock access.

The SPE manages the physical storage of the diskarrays. The SPE takes advantage of the industry-leading EMC UltraFlex™ technology and has twoindependent storage processors (SPs) that deliverdedicated, array-based processing power. Thecombination of the X-Blades with the SPE delivers theonly truly integrated, highly available, unified

offering based on industry-leading technologies.

Your choice of the most flexibleavailability optionsNS-120 can be deployed in several operating modesincluding primary/standby or primary/primary with N+1failover.

Primary/standby is designed for environments thatcannot tolerate any system downtime due to a hardwarefailure. In this mode, one of the X-Blades operates instandby mode while the primary one manages all of thedata movement between the network and storage. Insystems with greater than two X-Blades, one or moreblades can be configured as standby for the activeblades, providing a pool of blades for the highestlevels of availability. The standby blade(s)seamlessly take over the operation of any failingblade, delivering equal performance to the primarysystem after a failover, thus allowing the system tofully scale without concern for managing potentialresource constraints in the event of a failure.

Other environments that value performance overcontinuous availability can choose to operate theirdual X-Blade Celerra systems in primary/primary mode.Through a simple menu selection, both X-Blades can bemade available to handle unusually large loads anduser populations that can bring standard file serversto a virtual standstill.

Unequaled availability featuresWith the Celerra unified storage platform, no-compromise availability means non-stop file accessachieved through transparent, dynamic failover to ahot standby X-Blade. For information protection,Celerra unified systems offer EMC Celerra SnapSure™software for creating read-only/read-write copies offile systems and iSCSI LUNs. The snapshot can be usedfor online backups as well as quick recovery ofdeleted files. With the addition of Microsoft VolumeShadow Copy Services (VSS) integration, thiscapability is taken a step further, enabling the enduser to leverage the functionality in Windows XPclients to recover deleted files directly from theWindows Explorer user interface.

For an even higher degree of information protection,EMC Celerra Replicator™ creates an asynchronous point-in-time, read-only/read-write copy of a productionfile system on a local or geographically remoteCelerra system.

Native LUN replication, in the form of MirrorView™/Synchronous (MirrorView/S), is also supported foryour most critical data that requires zero-data-lossavailability in case of a disaster.

www.bull.com

PR

OD

UC

T S

PE

CIF

ICA

TIO

N

Page 2: NS-120

EMC Celerra NS-120 Technical Specifications

TECHNICAL HIGHLIGHTSNAS Server The Celerra NS-120 is an affordable,

unified storage system that scalesto 120 drives, connects to multiplestorage networks, and providesno-compromise availability

Single X-Blade configuration Instance of DART File Server softwareProcessor Dual 2.8 GHz LV Intel Xeon processorsMemory 4GB Double data Rate RAM (266MHz)

on a 288 MHz FSBBack-end Connectivity Two 4 Gb/s Fibre Channel ports for

storage array connectivityTape Connectivity Up to two 4Gb/s Fibre Channel ports

for tape connectivityNetwork Connectivity Four 10/100/1000 BaseT portsOptical Gigabit Ethernet port or two 10 Gigabit Ethernet Optical

ports and two 10/10/1000 BaseT portsManagement Connectivity One 10/100/1000 management port

Platform Management by a control station: contains a 3.4GHz Single Core Xeon CPU with 800MHz FSB, 2 MB cache, and 2 GB memory

- Connection to each X-Blade via10/100/1000 interface

- Manages X-Blade failover - Manages all file systems via GUI - SNMP MIB II manageability - Secure Shell (SSH) for remote

access - HTTP server management interface - Dual USB, 250 GB drive, DVD drive

Max. Capacity Up to 64 TB usable (32 TB max peractive X-Blade)

Min/Max. Disk Drives 6 to 120 disks in up to 8 drivetrays. Each tray can be configuredwith:– All FC drives– Mixed FC, SATA, and Flash* drives(FC, SATA, and Flash drives must bein separate trays)

DART File Server FacilitiesProtocols Supported

File Systems NFS v2/v3/v4, CIFS (SMB 1 & SMB2), FTP, iSCSI, Fibre Channel andMPFS

NLM Yes (v1/v3/v4)RIP Yes (v1-v2)SNMP YesNDMP Yes (v1-v4)ARP YesICMP YesNTP Yes (client)SNTP YesKerberos Authentication YesLDAP Yes

DART Software Facilities **Celerra Event Enabler Celerra Anti-virus, Celerra Event

Publishing AgentCelerra Replicator™ YesCelerra Manager Advanced Edition YesCelerra File-Level Retention Yes (Entreprise & Compliance)Celerra MPFS Yes

Client Connectivity FacilitiesFile Access by FTP, NFS, CIFS and MPFSBlock Access by iSCSI and Fibre Channel

HIGH AVAILABILITY FEATURESX-Blade Enclosure

- Redundant electrical powersupplies for the X-Blades

- Hot-swappable power and cooling - Internal environmental status

monitoring

PHYSICAL SPECIFICATIONSForm factor

X-Blade Enclosure NS-120 with 1 15 disk tray: 8 NEMAunits (U)

PHYSICAL SPECIFICATIONS (Cont'd)Expansion Disk Tray 3 NEMA units (U)

Dimensions (HxWxD)X-Blade Enclosure NS-120 with 1 15 disk tray:

35.6x48.06x80.21 cm (includingrails)

Expansion Disk Tray 13.34x45.0x35.56 cm

WeightX-Blade Enclosure NS-120 with 1 15 disk tray: 107.7 kgExpansion Disk Tray 30.8 kg

ENVIRONMENTTemperature 10-40 °CTemperature Gradient 10 °C/hrHumidity 20% to 80% (non-condensing)Altitude 2.286,40 m @ 40 °C max, 3.048 m @ 37

°C max

AC POWER and DISSIPATIONAC Line Voltage 100 to 240 V AC, 50–60 Hz,

single-phasePower consumption NS-120 with One 15-Disk Tray: 1.115

VA (970 W) maximum. Expansion DiskTray: 380 VA (365 W) max. (fullyconfigured)***

Startup Surge Current NS-120 with One 15-Disk Tray: 59 Arms max. for 50 ms, at any linevoltage. Expansion Disk Tray: 15 Apk (10.6 A rms) max. for 100 ms,at any line voltage

Power Factor 0.98 minimum at full load, low voltageHeat Dissipation NS-120 with One 15-Disk Tray: 3,400

Btu/hr max. Expansion Disk Tray:1,250 Btu/hr max.

In-rush current (estimate for 1/2 line cycle perline cord)

At 240 VAC NS-120 with One 15-Disk Tray: 138 Amax. Expansion Disk Tray: 50 A max.

At 120VAC NS-120 with One 15-Disk Tray: 69 Apeak

AC Protection 10 A fuse on each power supply, bothphases

Ride-through 30 ms minimum at full loadCurrent sharing NS-120 with One 15-Disk Tray: ±15%

of full load, between powersupplies. Expansion Disk Tray: ±10%of full load, between power supplies

REGULATORY & SAFETYSafety UL 60950; CSAC 22.2-60950, FN 60950;

Manufactured under an ISO9000-registered quality system; ETSIEN 300 386

Electromagnetic Compatibility (EMC) FCC Class A EN55022 Class A; CE MarkVCCI Class A (for Japan); ICES-003Class A (for Canada) AS/NZS 3548Class A (for Australia/NewZealand); EN55024 Immunity, ITEBSMI Class A (for Taiwan)

WARRANTYStandard warranty World Wide; 3-year Hardware Support,

9x5, Next Business Day, parts onlyExtended Warranty Bull’s Global Care offer: Bronze,

Silver and Gold levels; depends onlocation

*Flash drives are not configured in the first drive tray

**Celerra Manager-Basic, Virtual Provisioning, Deduplication, and SnapSure™ arebundled

***Ratings assume fully loaded disk array enclosure that includes two powersupplies, two LLCs, and 15 disk drives

Bull SAS - Bull acknowledges the rights of proprietors of trademarks mentioned herein. Bull reserves the right to modify this document at any time without notice. Some offers or parts of offersdescribed in this document may not be available in your country. Please consult your local Bull correspondent for information regarding the offers which may be available in your country.All trademarks and registered trademarks are the property of their respective owners.

Bull SAS - rue Jean Jaurès - 78340 Les Clayes-sous-Bois – FranceUK : Maxted Road, Hemel Hempstead, Herts HP2 7DZ

USA : 300 Concord Road, Billerica, MA 01821

www.bull.com© 2

011

Cop

yrig

ht B

ull S

AS

All

right

s re

serv

ed -

On-

the-

fly p

rinte

d on

20/

01/2

011

17:2

6:14