Np Dispensers

download Np Dispensers

of 22

description

DISPENSERS BASICS

Transcript of Np Dispensers

  • Technology Solution to detect and avoid Short Delivery Features to Ensure Correct Quantity:

    K Factors History Record Logging Counter History Record Electronic Totaliser Value at the time of Calibration.

    Steps for Calibration using Electronic Correction:

  • The Portion housing the Electronic components and Calibration switch is sealed by W&M Deptt.

    W&M Deptt. Seal

  • Calibration Procedure :

    1) Without Removing W&M Seal- Calibration mechanism is not accessible:

  • 2) Remove Housing Containing CPU (Central Processing Unit ) PCB (Printed Circuit Board):

  • 3) CPU PCB and Calibration switch accessible only after removing Housing / Plug

    Calibration Switch (Normal Conditions Off)

    CPU PCB

  • 4) Change Calibration Switch to On Position:

    Calibration Switch Changed to On Position

  • 5) Enter Programming Mode through Password

    Programming mode Parameter 1

  • 6) Enter in Calibration Mode:

    Calibration Mode Parameter

  • 7) Nozzles Delivery Check using Standard Measuring Can

    Zero Display

  • 8) Lift the Nozzle for Dispensing in Measuring Can

  • 9) Stop Dispensing after Filling Measuring Can

    Actual Quantity Dispensed =10 Liter Dispenser displaying More Short Delivery

  • Replace Nozzle Back

  • 10) Feed in Actual Dispensed Quantity(10.000) using Keypad

    10.000 Enter by Keypad

    Keypad

  • Generation of K Factor

    Range of Calibration is +/- 100 ml for 5 Liters. Beyond this range Calibration is not Possible- Electronics will

    give Error Condition

    K Factor Generated Automatically Stored in Memory

  • 11) After Successful Calibration Electronic Housing Sealed by W&M Deptt.

  • Audit Trail Mechanism for W&M Deptt ( At any time); Data Stored in Dispenser is Non Tamperable

    Logging Counter Three Digit Non Editable internal counter, This Counter increases its value after each successful Calibration attempts

    Logging Counter Specifying Total Calibration attempts on respective Nozzle

  • Record History 1

    Electronic Totaliser Value- At the time of Calibration

    K Factor (Last)

  • Record History 2

    Electronic Totaliser Value- At the time of Calibration

    K Factor (Second Last)

  • Record History 3

    Electronic Totaliser Value- At the time of Calibration

    K Factor (Third Last)