Now you’re in control.
Transcript of Now you’re in control.
Bringing the Honeywell Home Brand to market, and with over 100 years of experience, Resideo delivers trusted home solutions that provide comfort, control and peace of mind to families across the world.
We don’t believe that one size fits all. Our portfolio is one of the largest and most comprehensive in the market, meaning there’s something to suit every application. All of our products guarantee simple installation, everyday ease of use and the flexibility to integrate with any boiler, system or application.
We understand what our customers want – but that’s not the whole story. We wouldn’t be where we are today without the professionals behind our brand.
That’s why we provide continued support to those who sell, specify and install our products – especially as these products get smarter by the day.
Timeswitches and programmersThe ST9000 and Sundial RF2 ranges
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
For more informationheatingcontrols.honeywellhome.com
Classic controlsClassic time controls are recommended only for use as like-for-like replacements. They come in either a
1-day programmer version (ST699) or a 7-day programmer version (ST799).
Single channel timeswitch controlsST9100 single channel timeswitches are designed for control of a single heating zone or combi boiler
applications. The three timeswitches in the range are:
• ST9100A – 1-day timeswitch
• ST9100C – 7-day timeswitch to suit 7-day, and 5/2 day, timing profiles
• ST9100S – 1-day timeswitch with a service interval reminder.
Two channel programmersST9400 programmers are two channel programmers with independent timing for control of heating and
hot water. The three programmers in the range are:
• S9400A – 1-day programmer with two channels
• ST9400C – 7-day programmer, two channels to suit 7-day or 5/2-day timing profiles
• ST9400S – 1-day programmer, two channel model with a service interval reminder.
Two zone programmersST9500C is a two channel 7-day full programmer designed to control two heating zones. Zoning a house
not only helps make the heating system more energy efficient, but can also improve comfort conditions,
as each zone will only be heated when required. Building regulations strongly recommend zoning for
most houses and mandate it for certain larger properties.
Wireless enabled packsSundial RF2 packs are boxed sets of controls that feature a combination of a wireless enabled timer,
wireless thermostat and wireless cylinder thermostat to suit a range of installation types.
ENR3 0056 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
ST6991 Day Classic Programmer
The ST699 time control programmer can be used as a
replacement programmer on gravity, primary or fully
pumped systems.
The ST699 has a proven, easy-to-use design. The front
panels of each programmer will fit to the same back plate.
Programming the timing sequence is straightforward,
using the top slider switch and [+] and [−] buttons.
Please note it is recommended that, in order to comply with Part L1 Building Regulations, central heating systems should be upgraded to fully pumped with a fully independent programmer, e.g. ST9400C.
InstallationThe ST699 programmer can be either surface or flush
mounted, for both of which fixing screws are supplied. The
wiring sub-base has holes to suit single pattress boxes
and breakouts for surface and channelled wiring.
If used to provide time control for a gravity hot water /
pumped heating system, it is not possible to select
Heating only without Hot Water. For these installations a
Heating and Hot Water sticker is supplied, which should
be placed over the existing HEATING caption.
Fixing screws are supplied for either surface or flush
mounting box.
F E AT U R E S
• Compact size, easy to operate
• Suitable for surface or switch box mounting
• Built-in battery backup
• One or two on/off periods per day
• Double insulated
• 12-hour display with AM/PM indication
ENR3 0042 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
SPECIFICATION
Voltage Rating 230 VAC, ±10%, 50…60 Hz
Switch Rating 3 A inductive, 3A resistive
Switch Type 2 x single pole, double throw (SPDT) Volt-free contacts
Battery Backup Integral rechargeable NiCad
Storage Conditions −20 to 55°C
Humidity 10 to 90% RH, non-condensing
Standards CE marked
EC Directive 89/336/EEC & 73/23/EEC
For more informationheatingcontrols.honeywellhome.com
WiringFor full wiring instructions, please refer to the
Wiring Guide or download the Honeywell Home
Wiring Guide App from the Apple App Store or
Google Play Store.
Download the new Honeywell Home ‘Wiring Guide’ app
ST7997 Day Classic Programmer
The ST799 time control programmer can be used as a
replacement programmer on gravity, primary or fully
pumped systems.
The ST799 offers a flexible 7-day programme. The front
panel of the programmer will fit to the same back plate.
Programming the timing sequence is straightforward,
using the top slider switch and [+] and [−] buttons.
Please note it is recommended that, in order to comply with Part L1 Building Regulations, central heating systems should be upgraded to fully pumped with a fully independent programmer, e.g. ST4900C.
InstallationThe ST799 programmer can be either surface or flush
mounted, for both of which fixing screws are supplied. The
wiring sub-base has holes to suit single pattress boxes
and breakouts for surface and channelled wiring.
If used to provide time control for a gravity hot water /
pumped heating system, it is not possible to select
Heating only without Hot Water. For these installations a
Heating and Hot Water sticker is supplied, which should
be placed over the existing HEATING caption.
Fixing screws are supplied for either surface or flush
mounting box.
F E AT U R E S
• Compact size, easy to operate
• Suitable for surface or switch box mounting
• Built-in battery backup
• One or two on/off periods per day
• Double insulated
ENR3 0043 UK01 D0419 © 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
SPECIFICATION
Voltage Rating 230 VAC, ±10%, 50…60 Hz
Switch Rating 3A inductive, 3A resistive
Switch Type 2 x single pole, double throw (SPDT) Volt-free contacts
Battery Backup Integral rechargeable NiCad
Storage Conditions −20 to 55°C
Humidity 10 to 90% RH, non-condensing
Standards CE marked
EC Directive 89/336/EEC & 73/23/EEC
For more informationheatingcontrols.honeywellhome.com
WiringFor full wiring instructions, please refer to the
Wiring Guide or download the Honeywell Home
Wiring Guide App from the Apple App Store or
Google Play Store.
Download the new Honeywell Home ‘Wiring Guide’ app
ST9100A1 Day Single Channel Timeswitch
The ST9100A is a single channel timer, designed
primarily for control of a single heating zone or combi
boiler application. It is suitable for mains, low voltage or
potential-free switching of the heating load. This model
is a 1-day timer with two on/off switching times per day
(which can be increased to three). It can be used for combi
boilers, heating zones or any application where small
electric loads need switching.
All ST9100 models incorporate the Line of Text (LoT)
display that gives clear, plain English instructions
whenever any button or slider is used. This means
that installers, customers and users can operate all
the controls reliably, without needing to find an
instruction manual.
F E AT U R E S
• LoT display, providing text feedback that gives help and programming hints
• Large backlit display
• Factory-set clock and date
• Automatic summer/winter 1 hour time change
• Temporary or permanent override facilities
• Extra hour facility for up to 3 hours boost or programme extension
• Choice of three different built-in programmes
• Programme indicator lights
• Fits on standard industry back plate
• Direct replacement for ST6100 models
• Suitable for mains, low voltage or potential-free switching
• Any programmed settings retained indefinitely in non-volatile memory
• Up to three on/off times per day
ENR3 0044 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
SPECIFICATION
Switch Rating 3 A resistive, 3 A inductive at 230 VAC, 10 mA at 12 VDC min
Switch Type 1 x Single pole, double throw (SPDT) potential-free relay
Power Supply 230 VAC 50 Hz 10 W
Power Reserve In-built battery maintains factory-set date and time. Backup super-capacitor retains real time for more than 1.5 hours All settings and parameters stored in NVRAM will be retained indefinitely
Wiring Wiring terminals < 2.5 mm2 with cage clamps
Time Setting Resolution Time of day – 1 minute Programme time changes – 10 minutes
Time Display 24 hr or 12 hr AM/PM format
Timing Accuracy Typically better than 10 minutes per year Time and date factory set
Operating Temperature Range 0 to 40°C
Operating Humidity Range 10 to 90% RH, non-condensing
Storage Conditions −20 to 55°C
European Standards EN60730-2-7
EC Directive CE mark Conforms to protection requirements of Directives 2006/95EC and 89/336EC (as amended by 04/108/EC) WEEE & RoHS compliant
InstallationThe ST9100A can either be surface or flush
switch box mounted. The wiring sub-base has
holes to suit single switch boxes and provision for
surface wiring.
When wiring is completed, the front module
is slotted onto the sub-base and secured by
tightening the retaining screws.
WiringFor full wiring instructions, please refer to the
Wiring Guide or download the Honeywell Home
Wiring Guide App from the Apple App Store or
Google Play Store.
For more informationheatingcontrols.honeywellhome.com
Download the new Honeywell Home ‘Wiring Guide’ app
ST9100C7 Day Single Channel Timeswitch
The ST9100C is a single channel timer, designed
primarily for control of a single heating zone or combi
boiler application. It is suitable for mains, low voltage or
potential-free switching of the heating load. This model
is a 7-day timer that gives great flexibility, offering up to
three on/off switching times per day. Additionally, each
day can be programmed differently.
The ST9100C model is ideal for combi boiler installations
or multi-zone systems when the user has different
heating needs from day to day. It can be set to a 5/2-day
or 1-day programme during installation.
All ST9100 models incorporate the Line of Text (LoT)
display that gives clear, plain English instructions
whenever any button or slider is used. This means that
installers, customers and users can operate all the
controls reliably, without needing to find an instruction
manual. ST9100C also features a ‘Holiday’ button
enabling the user to switch off their heating for a
specified number of days (1 to 99) while they are away
from home.
F E AT U R E S
• LoT display, providing text feedback that gives help and programming hints
• Large backlit display
• Factory-set clock and date
• Automatic summer/winter 1 hour time change
• Temporary or permanent override facilities
• Extra hour facility for up to 3 hours boost or programme extension
• Choice of different built-in programmes
• Programme indicator lights
• Fits on industry standard back plate
• Direct replacement for ST6100 models
• Suitable for mains, low voltage or potential-free switching
• Any programmed settings retained indefinitely in non-volatile memory
• Up to three on/off times per day
• ‘Holiday’ button
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
SPECIFICATION
Switch Rating 3 A resistive, 3 A inductive at 230 VAC, 10 mA at 12 VDC min
Switch Type 1 x Single pole, double throw (SPDT) potential-free relay
Power Supply 230 VAC 50 Hz 10 W
Power Reserve In-built battery maintains factory-set date and time. Backup super-capacitor retains real time for more than 1.5 hours All settings and parameters stored in NVRAM will be retained indefinitely
Wiring Wiring terminals < 2.5 mm2 with cage clamps
Time Setting Resolution Time of day – 1 minute Programme time changes – 10 minutes
Time Display 24 hr or 12 hr AM/PM format
Timing Accuracy Typically better than 10 minutes per year Time and date factory set
Operating Temperature Range 0 to 40°C
Operating Humidity Range 10 to 90% RH, non-condensing
Storage Conditions −20 to 55°C
European Standards EN60730-2-7
EC Directive CE mark Conforms to protection requirements of Directives 2006/95EC and 89/336EC (as amended by 04/108/EC) WEEE & RoHS compliant
InstallationThe ST9100C can either be surface or flush
switch box mounted. The wiring sub-base has
holes to suit single switch boxes and provision for
surface wiring.
When wiring is completed, the front module
is slotted onto the sub-base and secured by
tightening the retaining screws.
WiringFor full wiring instructions, please refer to the
Wiring Guide or download the Honeywell Home
Wiring Guide App from the Apple App Store or
Google Play Store.
For more informationheatingcontrols.honeywellhome.com
Download the new Honeywell Home ‘Wiring Guide’ app
ENR3 0045 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
ST9100S1 Day Service Timeswitch
The ST9100S is a Service Interval time controller with
additional features to help landlords comply with
the requirements of Regulation 36 of the Gas Safety
(Installation and Use) Regulations 1998. The landlord,
installer or service company can configure the Service
Interval, the advance tenant notification period, and
how the controller will operate when the Service Interval
has expired.
This model looks and operates exactly as standard
ST9000 models until the gas service is due, at which
point the predetermined action takes place. The Line of
Text (LoT) display can also be used to show a telephone
number to help the user arrange their gas service.
This model is a 1-day timer with Service Interval reminder,
and two on/off switching times per day. This unit can be
used for combi boilers, added zones or any application
where small electric loads need switching. The ST9100S
complies fully with Building Regulations Part L1 for
England and Wales.
F E AT U R E S
• Service Interval reminder with variable levels of action
• LoT display, providing text feedback that gives help and programming hints
• Large backlit display
• Factory-set clock and date
• Automatic summer/winter 1 hour time change
• Temporary or permanent override facilities
• Extra hour facility, for up to 3 hours boost or programme extension
• Choice of three different built-in programmes
• Programme indicator lights
• Fits on industry standard back plate
• Direct replacement for ST6100 and ST6400 models
• Any programmed settings retained indefinitely in non-volatile memory
• Two on/off times per day
• Suitable for mains, low voltage or potential-free switching
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
SPECIFICATION
Switch Rating 3 A resistive, 3 A inductive at 230 VAC, 10 mA at 12 VDC min
Switch Type 2 x Single pole, single throw (SPST) relays
Power Supply 230 VAC 50 Hz 10 W
Power Reserve In-built battery maintains factory-set date and time. Backup super-capacitor retains real time for more than 1.5 hours All settings and parameters stored in NVRAM will be retained indefinitely
Wiring Wiring terminals < 2.5 mm2 with cage clamps
Time Setting Resolution Time of day – 1 minute Programme time changes – 10 minutes
Time Display 24 hr or 12 hr AM/PM format
Timing Accuracy Typically better than 10 minutes per year Time and date factory set
Operating Temperature Range 0 to 40°C
Operating Humidity Range 10 to 90% RH, non-condensing
Storage Conditions −20 to 55°C
European Standards EN60730-2-7
EC Directive CE mark Conforms to protection requirements of Directives 2006/95EC and 89/336EC (as amended by 04/108/EC) WEEE & RoHS compliant
InstallationThe ST9100S can either be surface or flush
switch box mounted. The wiring sub-base has
holes to suit single switch boxes and provision for
surface wiring.
When wiring is completed, the front module
is slotted onto the sub-base and secured by
tightening the retaining screws.
WiringFor full wiring instructions, please refer to the
Wiring Guide or download the Honeywell Home
Wiring Guide App from the Apple App Store or
Google Play Store.
For more informationheatingcontrols.honeywellhome.com
Download the new Honeywell Home ‘Wiring Guide’ app
ENR3 0046 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
ST9400A1 Day 2 Channel Programmer
The ST9400A is a two channel programmer, designed for
control of both heating and stored hot water in complete
systems. The heating and hot water programmes are
completely independent, to enable the system to be
operated in the most energy efficient manner possible.
The unit is a 1-day full programmer with two on/off
switching times per day (which can be increased to three).
It can be used for combi boilers, heating zones or any
application where small electric loads need switching.
The ST9400A can also be set as a mini programmer for
older gravity circulation stored hot water systems, where
there is no interlocking control valve.
All ST9400 models incorporate the Line of Text (LoT)
display that gives clear, plain English instructions
whenever any button or slider is used. This means that
installers, customers and users can operate all the controls
reliably, without needing to find an instruction manual. The
ST9400A complies fully with Building Regulations Part L1
for England and Wales, and Part J for Scotland.
F E AT U R E S
• LoT display, providing text feedback that gives help and programming hints
• Large backlit display
• Factory-set clock and date
• Automatic summer/winter 1 hour time change
• Temporary or permanent override facilities
• Extra hour facility, for up to 3 hours boost or programme extension
• Choice of three different built-in programmes
• Programme indicator lights
• Fits on industry standard back plate
• Direct replacement for ST6400 models
• Any programmed settings retained indefinitely in non-volatile memory
• Up to three on/off times per day
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
SPECIFICATION
Switch Rating 3 A resistive, 3 A inductive at 230 VAC, 10 mA at 12 VDC min
Switch Type 2 x Single pole, double throw (SPDT) relays
Power Supply 230 VAC 50 Hz 10 W
Power Reserve In-built battery maintains factory-set date and time. Backup super-capacitor retains real time for more than 1.5 hours All settings and parameters stored in NVRAM will be retained indefinitely
Wiring Wiring terminals < 2.5 mm2 with cage clamps
Time Setting Resolution Time of day – 1 minute Programme time changes – 10 minutes
Time Display 24 hr or 12 hr AM/PM format
Timing Accuracy Typically better than 10 minutes per year Time and date factory set
Operating Temperature Range 0 to 40°C
Operating Humidity Range 10 to 90% RH, non-condensing
Storage Conditions −20 to 55°C
European Standards EN60730-2-7
EC Directive CE mark Conforms to protection requirements of Directives 2006/95EC and 89/336EC (as amended by 04/108/EC) WEEE & RoHS compliant
InstallationThe ST9400A can either be surface or flush
switch box mounted. The wiring sub-base has
holes to suit single switch boxes and provision for
surface wiring.
When wiring is completed, the front module
is slotted onto the sub-base and secured by
tightening the retaining screws.
WiringFor full wiring instructions, please refer to the
Wiring Guide or download the Honeywell Home
Wiring Guide App from the Apple App Store or
Google Play Store.
For more informationheatingcontrols.honeywellhome.com
Download the new Honeywell Home ‘Wiring Guide’ app
ENR3 0047 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
ST9400C7 Day 2 Channel Programmer
The ST9400C is a two channel programmer, designed for
control of both heating and stored hot water in complete
systems. The heating and hot water programmes are
completely independent, to enable the system to be
operated in the most energy efficient manner possible.
This unit is a 7-day full programmer that gives great
flexibility, offering up to three on/off switchings per day.
Additionally, each day can be programmed differently,
which means it is ideal for when the user has different
heating needs from day to day. The ST9400C can be set
to a 5/2-day or 1-day programme during installation.
The ST9400C can also be set as a mini programmer for
older gravity circulation stored hot water systems, where
there is no interlocking control valve. All ST9400 models
incorporate the Line of Text (LoT) display that gives clear,
plain English instructions whenever any button or slider is
used. This means that installers, customers and users can
operate all the controls reliably, without needing to find an
instruction manual.
ST9400C also features a ‘Holiday’ button enabling the
user to switch off their heating for a specified number
of days (1 to 99) while they are away from home. The
ST9400C complies fully with Building Regulations Part
L1 for England and Wales, and Part J for Scotland.
F E AT U R E S
• LoT display, providing text feedback that gives help and programming hints
• Large backlit display
• Factory-set clock and date
• Automatic summer/winter 1 hour time change
• Temporary or permanent override facilities
• Extra hour facility, for up to 3 hours boost or programme extension
• Choice of three different built-in programmes
• Programme indicator lights
• Fits on industry standard back plate
• Direct replacement for ST6400 models
• Any programmed settings retained indefinitely in non-volatile memory
• Up to three on/off times per day
• ‘Holiday’ button
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
SPECIFICATION
Switch Rating 3 A resistive, 3 A inductive at 230 VAC, 10 mA at 12 VDC min
Switch Type 2 x Single pole, double throw (SPDT) relays
Power Supply 230 VAC 50 Hz 10 W
Power Reserve In-built battery maintains factory-set date and time. Backup super-capacitor retains real time for more than 1.5 hours All settings and parameters stored in NVRAM will be retained indefinitely
Wiring Wiring terminals < 2.5 mm2 with cage clamps
Time Setting Resolution Time of day – 1 minute Programme time changes – 10 minutes
Time Display 24 hr or 12 hr AM/PM format
Timing Accuracy Typically better than 10 minutes per year Time and date factory set
Operating Temperature Range 0 to 40°C
Operating Humidity Range 10 to 90% RH, non-condensing
Storage Conditions −20 to 55°C
European Standards EN60730-2-7
EC Directive CE mark Conforms to protection requirements of Directives 2006/95EC and 89/336EC (as amended by 04/108/EC) WEEE & RoHS compliant
InstallationThe ST9400C can either be surface or flush
switch box mounted. The wiring sub-base has
holes to suit single switch boxes and provision for
surface wiring.
When wiring is completed, the front module
is slotted onto the sub-base and secured by
tightening the retaining screws.
WiringFor full wiring instructions, please refer to the
Wiring Guide or download the Honeywell Home
Wiring Guide App from the Apple App Store or
Google Play Store.
For more informationheatingcontrols.honeywellhome.com
Download the new Honeywell Home ‘Wiring Guide’ app
ENR3 0048 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
ST9400S1 Day Service Programmer
The ST9400S Service Interval time controller has
additional features to help landlords comply with
the requirements of Regulation 36 of the Gas Safety
(Installation and Use) Regulations 1998. The landlord,
installer or service company can configure the Service
Interval, the advance tenant notification period, and
how the controller will operate when the Service Interval
has expired.
This model looks and operates exactly as standard
ST9000 models until the gas service is due, at which
point the predetermined action takes place. The Line of
Text (LoT) display can also be used to show a telephone
number to help the user arrange their gas service. This
model is a 1-day full programmer with Service Interval
reminder, and two on/off switching times per day. Heating
and hot water can be programmed independently.
The ST9400S complies fully with Building Regulations
Part L1 for England and Wales.
F E AT U R E S
• Service Interval reminder with variable levels of action
• LoT display, providing text feedback that gives help and programming hints
• Large backlit display
• Factory-set clock and date
• Automatic summer/winter 1 hour time change
• Temporary or permanent override facilities
• Extra hour facility, for up to 3 hours boost or programme extension
• Choice of three different built-in programmes
• Programme indicator lights
• Fits on industry standard back plate
• Any programmed settings retained indefinitely in non-volatile memory
• Two on/off times per day
• Direct replacement for ST6100 and ST6400 models
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
SPECIFICATION
Switch Rating 3 A resistive, 3 A inductive at 230 VAC, 10 mA at 12 VDC min
Switch Type 2 x Single pole, double throw (SPDT) relays
Power Supply 230 VAC 50 Hz 10 W
Power Reserve In-built battery maintains factory-set date and time. Backup super-capacitor retains real time for more than 1.5 hours All settings and parameters stored in NVRAM will be retained indefinitely
Wiring Wiring terminals < 2.5 mm2 with cage clamps
Time Setting Resolution Time of day – 1 minute Programme time changes – 10 minutes
Time Display 24 hr or 12 hr AM/PM format
Timing Accuracy Typically better than 10 minutes per year Time and date factory set
Operating Temperature Range 0 to 40°C
Operating Humidity Range 10 to 90% RH, non-condensing
Storage Conditions −20 to 55°C
European Standards EN60730-2-7
EC Directive CE mark Conforms to protection requirements of Directives 2006/95EC and 89/336EC (as amended by 04/108/EC) WEEE & RoHS compliant
InstallationThe ST9400S can either be surface or flush
switch box mounted. The wiring sub-base has
holes to suit single switch boxes and provision for
surface wiring.
When wiring is completed, the front module
is slotted onto the sub-base and secured by
tightening the retaining screws.
WiringFor full wiring instructions, please refer to the
Wiring Guide or download the Honeywell Home
Wiring Guide App from the Apple App Store or
Google Play Store.
For more informationheatingcontrols.honeywellhome.com
Download the new Honeywell Home ‘Wiring Guide’ app
ENR3 0049 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
ST9500C7 Day 2 Zone Programmer
The ST9500C is a two channel 7-day full programmer
designed to control two heating zones. Zoning a house
not only helps make the heating system more energy
efficient, but can also improve comfort conditions, as
each zone will only be heated when required.
This programmer gives great flexibility, offering up to
three on/off switching times per day. Additionally each
day can be programmed differently, making it ideal for
when the user has different heating needs from day
to day. The ST9500C can be set to a 5/2-day or 1-day
programme during installation.
All ST9000 models incorporate the Line of Text (LoT)
display that gives clear, plain English instructions
whenever any button or slider is used. This means
that installers, customers and users can operate all
the controls reliably, without needing to find an
instruction manual.
The ST9500C also features a ‘Holiday’ button enabling
the user to switch off their heating for a specified number
of days (1 to 99) while they are away from home.
Building Regulations strongly recommend zoning
for most houses, and mandate it for certain larger
properties, so the Honeywell ST9500C can be used as
an aid to compliance.
F E AT U R E S
• LoT display, providing text feedback that gives help and programming hints
• Large backlit display
• Factory-set clock and date
• Automatic summer/winter 1 hour time change
• Temporary or permanent override facilities
• Extra hour facility, for up to 3 hours boost or programme extension
• Choice of three different built-in programmes
• Programme indicator lights
• Fits on industry standard back plate
• Direct replacement for ST6400 models
• Any programmed settings retained indefinitely in non-volatile memory
• Up to three on/off times per day
• ‘Holiday’ button
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
SPECIFICATION
Switch Rating 3 A resistive, 3 A inductive at 230 VAC, 10 mA at 12 VDC min
Switch Type 2 x Single pole, double throw (SPDT) relays
Power Supply 230 VAC 50 Hz 10 W
Power Reserve In-built battery maintains factory-set date and time. Backup super-capacitor retains real time for more than 1.5 hours All settings and parameters stored in NVRAM will be retained indefinitely
Wiring Wiring terminals < 2.5 mm2 with cage clamps
Time Setting Resolution Time of day – 1 minute Programme time changes – 10 minutes
Time Display 24 hr or 12 hr AM/PM format
Timing Accuracy Typically better than 10 minutes per year Time and date factory set
Operating Temperature Range 0 to 40°C
Operating Humidity Range 10 to 90% RH, non-condensing
Storage Conditions −20 to 55°C
European Standards EN60730-2-7
EC Directive CE mark Conforms to protection requirements of Directives 2006/95EC and 89/336EC (as amended by 04/108/EC) WEEE & RoHS compliant
InstallationThe ST9500C can either be surface or flush
switch box mounted. The wiring sub-base has
holes to suit single switch boxes and provision for
surface wiring.
When wiring is completed, the front module
is slotted onto the sub-base and secured by
tightening the retaining screws.
WiringFor full wiring instructions, please refer to the
Wiring Guide or download the Honeywell Home
Wiring Guide App from the Apple App Store or
Google Play Store.
For more informationheatingcontrols.honeywellhome.com
Download the new Honeywell Home ‘Wiring Guide’ app
ENR3 0050 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
Sundial RF2 Pack 1 Wireless Enabled Timer and Thermostat (Y9120H2009)
In a heating system with a combination boiler or added
zones, with no room thermostat, the existing wiring
can be used to provide Boiler Interlock by fitting Sundial
RF2 Pack 1.
The pack contains:
• A wireless-enabled timer (ST9120C)
• A wireless room thermostat (DT92E).
Communication between the timeswitch and thermostat,
as well as features such as Optimum Start*, Delayed
Start** and Optimum Stop***, enable users to save money
and energy.
O P T I O N S
F E AT U R E S
• Remote Boiler control with wireless relay box (BDR91 supplied separately)
* Optimum Start: To save energy, let the controls work out when to come on to suit when you want to be warm. Every day, the boiler will start at the latest possible moment depending on the weather.
** Delayed Start: Once you have programmed your earliest start time, the controls will delay the boiler firing time on warmer days, when it is possible to save energy.
*** Optimum Stop: Saves energy and money by switching off before the normal programme time whenever possible.
• Energy-saving Time Proportional and Integral (TPI) control
• Wireless-enabled upgrade
• Two-way wireless communication
• Wireless signal strength indicator
• Built-in Economy or Comfort programmes on ST9120C
• Line of Text (LoT) display for easy programming on ST9120C
• ST9120C fits on industry standard back plate
• ST9120C is a direct replacement for ST9100 and ST6100 models
• ECO setback function on DT92E
• Frost protection on DT92E
• Table-top stand supplied for DT92E
• Battery powered – no wiring for DT92E
ErP energy efficiency ratingsThe ErP energy efficiency ratings shown in this brochure will provide installers and end users with the information required to both complete the ErP energy label and assess the benefits of the heating controls to the overall heating system in the property. These ratings apply to room thermostats (including programmable thermostats).
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
SPECIFICATION
Pack 1
RF Operation Band ISM (868.0 to 868.6 MHz), 1% duty cycle
RF Communication Range Typically 30 m in residential building
RF Communication Technology Two-way short, high-rate transmissions to minimise air time / avoid interference
RF Blocking Immunity Receiver class 2
Operating Temperature Range 0 to 40°C
Operating Humidity Range 10 to 90% RH, non-condensing
Storage Conditions −20 to 55°C10 to 90% RH, non-condensing
Standards CE marked
IP Rating IP30
ST9120C
Switch Rating 3(3)A max at 230 VAC, 10 mA minimum at 12 VDC
Switch Type 1x Single pole, double throw (SPDT) potential-free relay
Power Supply 230 VAC 50 Hz 10 W
Power Reserve Built-in battery maintains factory-set date and time. Backup super capacitor retains real time for more than 1.5 hours All settings and parameters stored in NVRAM will be retained indefinitely
Wiring Wiring terminals with captive cage clamps, accepting two wires each up to 2.5 mm2
Time Setting Resolution Time of day – 1 minute Programme time changes – 10 minutes
Time Display 24 hour or 12 hour AM/PM format
Timing Accuracy Typically better than 10 minutes per year Time and date factory set
DT92E
Power Supply Two AA size, 1.5 V alkaline batteries
Temperature Setting Range 5 to 35°C in 0.5°C steps Can be limited between 5 and 35°C
OFF Set point Temperature 5°C (default) Can be set between 5 and 16°C or turned off
ECO Set point Temperature 18°C (default) Can be set between 5 and 35°C (in 1°C steps), for 1 to 24 hours
Temperature Control Accuracy ±0.5 K at 20°C (50% load, 3 K/hr)
For more informationheatingcontrols.honeywellhome.com
InstallationSimply remove the old timer and replace with
ST9120C. This enables the wireless thermostat
(DT92E) to be added to the system.
The ST9120C and DT92E are radio frequency devices
and for best performance should be installed in a clear
space. Where possible, leave the ST9120C at least 30
cm from any metal objects, including wall boxes, and
at least 1 m from any other electrical equipment.
The DT92E is free to be installed in a suitable location
where the signal strength is high.
WiringFor full wiring instructions, please refer to the Wiring
Guide or download the Honeywell Home Wiring Guide
App from the Apple App Store or Google Play Store.
Download the new Honeywell Home ‘Wiring Guide’ app
ENR3 0051 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
Sundial RF2 Pack 2 Wireless Enabled Programmer and Thermostat (Y9420H1008)
In a stored hot water heating system which has no room
thermostat, the existing wiring can be used to provide
Boiler Interlock by fitting Sundial RF2 Pack 2.
The pack contains:
• A wireless-enabled programmer (ST9420C)
• A wireless room thermostat (DT923E).
Communication between the programmer and
thermostat, as well as features such as Optimum Start*,
Delayed Start** and Optimum Stop***, enable users to
save money and energy.
F E AT U R E S
* Optimum Start: To save energy, let the controls work out when to come on to suit when you want to be warm. Every day, the boiler will start at the latest possible moment depending on the weather.
**D elayed Start: Once you have programmed your earliest start time, the controls will delay the boiler firing time on warmer days, when it is possible to save energy.
*** Optimum Stop: Saves energy and money by switching off before the normal programme time whenever possible.
• Energy-saving Time Proportional and Integral (TPI) control
• Wireless-enabled upgrade
• Two-way wireless communication
• Wireless signal strength indicator
• Built-in Economy or Comfort programmes on ST9420C
• Line of Text (LoT) display for easy programming on ST9420C
• ST9420C fits on industry standard back plate
• ST9420C is a direct replacement for ST9400 and ST6400 models
• ECO setback function on DT92E
• Frost protection on DT92E
• Table-top stand supplied for DT92E
• Battery powered – no wiring for DT92E
• Boiler Plus compliant for system boilers
ErP energy efficiency ratingsThe ErP energy efficiency ratings shown in this brochure will provide installers and end users with the information required to both complete the ErP energy label and assess the benefits of the heating controls to the overall heating system in the property. These ratings apply to room thermostats (including programmable thermostats).
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
For more informationheatingcontrols.honeywellhome.com
InstallationSimply remove the old programmer and replace with
ST9420C. This enables the wireless thermostat
(DT92E) to be added to the system.
The ST9420C and DT92E are radio frequency devices
and for best performance should be installed in a clear
space. Where possible, leave the ST9420C at least 30
cm from any metal objects, including wall boxes, and
at least 1 m from any other electrical equipment.
The DT92E is free to be installed in a suitable location
where the signal strength is high.
Do not subject the room thermostat to extraneous
heat gains, direct sunlight or draughts.
WiringFor full wiring instructions, please refer to the Wiring
Guide or download the Honeywell Home Wiring Guide
App from the Apple App Store or Google Play Store.
SPECIFICATION
Pack 2
RF Operation Band ISM (868.0 to 868.6 MHz), 1% duty cycle
RF Communication Range Typically 30m in residential building
RF Communication Technology Two way short, high rate transmissions to minimise air time / avoid interference
RF Blocking Immunity Receiver class 2
Operating Temperature Range 0 to 40°C
Operating Humidity Range 10 to 90% RH, non-condensing
Storage Conditions −20 to 55°C 10 to 90% RH, non-condensing
Standards CE marked
IP Rating IP30
ST9420C
Switch Rating 3(3)A max at 230 VAC
Switch Type 2x Single pole, double throw (SPDT) relay
Power Supply 230 VAC 50 Hz 10 W
Power Reserve Built-in battery maintains factory-set date and time. Backup super capacitor retains real time for more than 1.5 hours All settings and parameters stored in NVRAM will be retained indefinitely
Wiring Wiring terminals with captive cage clamps, accepting two wires each up to 2.5 mm2
Time Setting Resolution Time of day – 1 minute Programme time changes – 10 minutes
Time Display 24 hour or 12 hour AM/PM format
Timing Accuracy Typically better than 10 minutes per year Time and date factory set
DT92E
Power Supply Two AA size, 1.5 V alkaline batteries
Temperature Setting Range 5 to 35°C in 0.5°C steps can be limited between 5 and 35°C
OFF Set point Temperature 5°C (default) Can be set between 5 and 16°C or turned off
ECO Set point Temperature 18°C (default) Can be set between 5 and 35°C (in 1°C steps), for 1 to 24 hours
Temperature Control Accuracy ±0.5 K at 20°C (50% load, 3 K/hr)
Download the new Honeywell Home ‘Wiring Guide’ app
ENR3 0052 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
Sundial RF2 Pack 3 Wireless Enabled Programmer and Thermostats (Y9420S2005)
In a stored hot water heating system which has no room
thermostat or cylinder thermostat, the existing wiring can
be used to provide Boiler Interlock by fitting Sundial RF2
Pack 3.
The pack contains:
• A wireless enabled programmer (ST9420C)
• A wireless room thermostat (DT92E)
• A wireless cylinder thermostat (CS92A).
Communication between the programmer and
thermostat, as well as features such as Optimum Start*,
Delayed Start** and Optimum Stop***, enable users to
save money and energy.
O P T I O N S
F E AT U R E S
• Remote Boiler control with wireless relay box (BDR91 supplied separately)
• Remote Valve control with wireless relay box (BDR91 supplied separately)
* Optimum Start: To save energy, let the controls work out when to come on to suit when you want to be warm. Every day, the boiler will start at the latest possible moment depending on the weather.
** Delayed Start: Once you have programmed your earliest start time, the controls will delay the boiler firing time on warmer days, when it is possible to save energy.
*** Optimum Stop: Saves energy and money by switching off before the normal programme time whenever possible.
• Energy-saving Time Proportional and Integral (TPI) control
• Wireless-enabled upgrade
• Two-way wireless communication
• Wireless signal strength indicator
• Built-in Economy or Comfort programmes on ST9420C
• Line of Text (LoT) display for easy programming on ST9420C
• ST9420C fits on industry standard back plate
• ST9420C is a direct replacement for ST9400 and ST6400 models
• ECO setback function on DT92E
• Frost protection on DT92E
• Table-top stand supplied for DT92E
• CS92A set and controlled from programmer
• DT92E and CS92A both battery powered – no wiring
• Boiler Plus compliant for system boilers
ErP energy efficiency ratingsThe ErP energy efficiency ratings shown in this brochure will provide installers and end users with the information required to both complete the ErP energy label and assess the benefits of the heating controls to the overall heating system in the property. These ratings apply to room thermostats (including programmable thermostats).
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
For more informationheatingcontrols.honeywellhome.com
InstallationSimply remove the old programmer and replace with
ST9420C. This enables the wireless thermostat
(DT92E) and wireless cylinder thermostat (CS92A)
to be added to the system.
The ST9420C, DT92E and CS92A are radio frequency
devices and for best performance should be installed
in a clear space. Where possible, leave the ST9420C
at least 30 cm from any metal objects, including
wall boxes, and at least 1 m from any other electrical
equipment.
The DT92E is free to be installed in a suitable location
where the signal strength is high.
The CS92A wireless transceiver should be located
next to the cylinder with its sensor in contact with the
metal surface.
WiringFor full wiring instructions, please refer to the Wiring
Guide or download the Honeywell Home Wiring Guide
App from the Apple App Store or Google Play Store.
SPECIFICATION
Pack 3
RF Operation Band ISM (868.0 to 868.6 MHz), 1% duty cycle
RF Communication Range Typically 30 m in residential building
RF Communication Technology Two way short, high rate transmissions to minimise air time / avoid interference
RF Blocking Immunity Receiver class 2
Operating Temperature Range 0 to 40°C
Operating Humidity Range 10 to 90% RH, non-condensing
Storage Conditions −20 to 55°C 10 to 90% RH, non-condensing
Standards CE marked
IP Rating IP30
ST9420C
Switch Rating 3(3)A max at 230 VAC
Switch Type 2x Single pole, double throw (SPDT) relay
Power Supply 230 VAC 50 Hz 10 W
Power Reserve Built-in battery maintains factory-set date and time. Backup super capacitor retains real time for more than 1.5 hours All settings and parameters stored in NVRAM will be retained indefinitely
Wiring Wiring terminals with captive cage clamps, accepting two wires each up to 2.5 mm2
Time Setting Resolution Time of day – 1 minute Programme time changes – 10 minutes
Time Display 24 hour or 12 hour AM/PM format
Timing Accuracy Typically better than 10 minutes per year Time and date factory set
DT92E
Power Supply Two AA size, 1.5 V alkaline batteries
Temperature Setting Range 5 to 35°C in 0.5°C steps can be limited between 5 and 35°C
OFF Set point Temperature 5°C (default) Can be set between 5 and 16°C or turned off
ECO Set point Temperature 18°C (default) Can be set between 5 and 35°C (in 1°C steps), for 1 to 24 hours
Temperature Control Accuracy ±0.5 K at 20°C (50% load, 3 K/hr)
CS92A
Power Supply Two AA size, 1.5 V alkaline batteries
Temperature Setting Range 40 to 85°C
Cable Length 1.5 m between cylinder thermostat and transceiver
Download the new Honeywell Home ‘Wiring Guide’ app
ENR3 0053 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
Sundial RF2 Pack 4 Wireless Enabled Timer and Cylinder Thermostat (Y9120W1000)
In a stored hot water heating system which has no
cylinder thermostat, the existing wiring can be used to
provide Boiler Interlock by fitting Sundial RF2 Pack 4.
The pack contains:
• A wireless-enabled timer (ST9120C)
• A wireless cylinder thermostat (CS92A).
Maintaining the traditional layout of separate time
control and thermostats, the Sundial RF2 Pack 4 is ideal
for systems controlled by heating-only programmable
thermostats or where a hot water cylinder is being added
to an existing heating system.
O P T I O N S
F E AT U R E S
• Service interval reminder with variable levels of action
• Installer set-up mode – controls can be matched to the system and user
• Energy-saving Time Proportional and Integral (TPI) control
• Wireless-enabled upgrade
• Two-way wireless communication
• Wireless signal strength indicator
• Built-in Economy or Comfort programmes on ST9120C
• Line of Text (LoT) display for easy programming on ST9120C
• ST9120C fits on industry standard back plate
• ST9120C is a direct replacement for ST9100 and ST6100 models
• CS92A controlled by timer
• Battery-powered CS92A – no wiring
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
For more informationheatingcontrols.honeywellhome.com
InstallationSimply remove the old timer (if fitted) and replace
with ST9120C. This enables the wireless cylinder
thermostat (CS92A) to be added to the system.
Otherwise, install as per installation instructions
supplied with product. Remote boiler and remote
valve installations are possible with wireless relay
boxes (supplied separately).
The ST9120C and CS92A are radio frequency devices
and for best performance should be installed in a clear
space. Where possible, leave the ST9120C at least 30
cm from any metal objects, including wall boxes, and
at least 1 m from any other electrical equipment.
The CS92A wireless transceiver should be located
next to the cylinder with its sensor in contact with the
metal surface.
WiringFor full wiring instructions, please refer to the Wiring
Guide or download the Honeywell Home Wiring Guide
App from the Apple App Store or Google Play Store.
SPECIFICATION
Pack 4
RF Operation Band ISM (868.0 to 868.6 MHz), 1% duty cycle
RF Communication Range Typically 30 m in residential building
RF Communication Technology Two way short, high rate transmissions to minimise air time / avoid interference
RF Blocking Immunity Receiver class 2
Operating Temperature Range 0 to 40°C
Operating Humidity Range 10 to 90% RH, non-condensing
Storage Conditions −20 to 55°C10 to 90% RH, non-condensing
Standards CE marked
IP Rating IP30
ST9120C
Switch Rating 3(3)A max at 230 VAC, 10 mA minimum at 12VDC
Switch Type 1x Single pole, double throw (SPDT) potential-free relay
Power Supply 230 VAC 50 Hz 10 W
Power Reserve Built-in battery maintains factory-set date and time. Backup super capacitor retains real time for more than 1.5 hoursAll settings and parameters stored in NVRAM will be retained indefinitely
Wiring Wiring terminals with captive cage clamps, accepting two wires each up to 2.5 mm2
Time Setting Resolution Time of day – 1 minuteProgramme time changes – 10 minutes
Time Display 24 hour or 12 hour AM/PM format
Timing Accuracy Typically better than 10 minutes per yearTime and date factory set
CS92
Power Supply Two AA size, 1.5 V alkaline batteries
Temperature Setting Range 40 to 85°C (set in ST9120C)
Sensor cable length 1.5 m between sensor and transceiver
Download the new Honeywell Home ‘Wiring Guide’ app
ENR3 0054 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
Sundial RF2 Pack 5 Wireless Enabled 2 Zone Programmer and Thermostats (Y9520Z1007)
In a heating system which has no room thermostat, or the
system needs upgrading to 2 heating zones, the existing
wiring can be used to provide Boiler Interlock by fitting
Sundial RF2 Pack 5.
The pack contains:
• A wireless enabled 2 zone programmer (ST9520C)
• 2 x wireless room thermostats (DT92E).
Communication between the programmer and
thermostat, as well as features such as Optimum Start*,
Delayed Start** and Optimum Stop***, enable users to
save money and energy.
O P T I O N S
F E AT U R E S
• OpenTherm Boiler Control**** (with suitable OpenTherm Boiler)
• Remote Boiler control with wireless relay box (BDR91 supplied separately)
• Remote Valve control with wireless relay box (BDR91 supplied separately)
• Service interval reminder with variable levels of action
• Installer set-up mode – controls can be matched to the system and user
* Optimum Start: To save energy, let the controls work out when to come on to suit when you want to be warm. Every day, the boiler will start at the latest possible moment depending on the weather.
** Delayed Start: Once you have programmed your earliest start time, the controls will delay the boiler firing time on warmer days, when it is possible to save energy.
*** Optimum Stop: Saves energy and money by switching off before the normal programme time whenever possible.
**** OpenTherm Boiler Control: OpenTherm provides more precise control on the boiler through the control of the gas valve. It enables the amount of heat provided by the boiler to be controlled to match the varying demand signal. By reducing the flow temperature to a minimum as it leaves the boiler, the return temperature is kept below the dew point (55°C) whenever possible, thus enabling the boiler to operate in condensing mode.
• Energy-saving Time Proportional and Integral (TPI) control
• Wireless-enabled upgrade
• Two-way wireless communication
• Wireless signal strength indicator
• Built-in Economy or Comfort programmes on ST9520C
• Line of Text (LoT) display for easy programming on ST9520C
• ST9520C fits on industry standard back plate
• ECO setback function on DT92E
• Frost protection on DT92E
• Table-top stand supplied with DT92E
• Battery-powered DT92E – no wiring
ErP energy efficiency ratingsThe ErP energy efficiency ratings shown in this brochure will provide installers and end users with the information required to both complete the ErP energy label and assess the benefits of the heating controls to the overall heating system in the property. These ratings apply to room thermostats (including programmable thermostats).
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
For more informationheatingcontrols.honeywellhome.com
InstallationSimply remove the old programmer and replace with
ST9520C. This enables the wireless thermostats
(DT92E) to be added to the system. Otherwise,
install as per installation instructions supplied with
product. Remote boiler and remote valve installations
are possible with wireless relay boxes (supplied
separately).
The ST9520C and DT92E are radio frequency devices
and for best performance should be installed in a clear
space. Where possible, leave the ST9520C at least
30 cm from any metal objects, including wall boxes,
and at least 1 m from any other electrical equipment.
The 2 x DT92E are free to be installed in suitable
locations where the signal strength is high.
WiringFor full wiring instructions, please refer to the Wiring
Guide or download the Honeywell Home Wiring Guide
App from the Apple App Store or Google Play Store.
SPECIFICATION
Pack 5
RF Operation Band ISM (868.0 to 868.6 MHz), 1% duty cycle
RF Communication Range Typically 30 m in residential building
RF Communication Technology Two way short, high rate transmissions to minimise air time / avoid interference
RF Blocking Immunity Receiver class 2
Operating Temperature Range 0 to 40°C
Operating Humidity Range 10 to 90% RH, non-condensing
Storage Conditions −20 to 55°C10 to 90% RH, non-condensing
Standards CE marked
IP Rating IP30
ST9520C
Switch Rating 3(3)A max at 230 VAC
Switch Type 2x Single pole, double throw (SPDT) relay
Power Supply 230 VAC 50 Hz 10 W
Power Reserve Built-in battery maintains factory-set date and time. Backup super capacitor retains real time for more than 1.5 hoursAll settings and parameters stored in NVRAM will be retained indefinitely
Wiring Wiring terminals with captive cage clamps, accepting two wires each up to 2.5 mm2
Time Setting Resolution Time of day – 1 minute Programme time changes – 10 minutes
Time Display 24 hour or 12 hour AM/PM format
Timing Accuracy Typically better than 10 minutes per yearTime and date factory set
DT92E
Power Supply Two AA size, 1.5 V alkaline batteries
Temperature Setting Range 5 to 35°C in 0.5°C steps can be limited between 5 and 35°C
OFF Set point Temperature 5°C (default) Can be set between 5 and 16°C or turned off
ECO Set point Temperature 18°C (default) Can be set between 5 and 35°C (in 1°C steps), for 1 to 24 hours
Temperature Control Accuracy ±0.5 K at 20°C (50% load, 3 K/hr)
Download the new Honeywell Home ‘Wiring Guide’ app
ENR3 0055 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
ENR3 0041 UK01 D0419© 2019 Ademco 1. All rights reserved.This document contains proprietary information of Ademco 1 and its affiliated companies and is protected by copyright and other international laws. Reproduction or improper use without specific written authorization of Ademco 1 is strictly forbidden. The Honeywell Home trademark is used under license from Honeywell International Inc.
Resideo Technologies, Inc.200 Berkshire Place
Winnersh
Berkshire
RG41 5RD
For more informationheatingcontrols.honeywellhome.com