Novel design of large X-ray optical system for astrophysical application
L. Pina1, R. Hudec1, V. Tichy1,
A. Inneman2, D. Cerna2 , J. Marsik2, V. Marsikova2,
W. Cash3, A. F. Shipley3 and B. R. Zeiger3, T. D. Rogers3,
R. Melich4
1Czech Technical Univ. in Prague, Czech Republic
2Rigaku Innovative Technologies Europe, Czech Republic
3Univ. of Colorado at Boulder, United States
4CAS IPP, TOPTEC, Turnov, Czech Republic
AXRO December 2012 1
Motivation
• Study of new technologies for large X-ray telescopes
• Extraordinary requirements on accuracy – resolution of optical system around few arcsec
• This type of optical system has to be assembled from many small segments and thousands of mirrors (unlike only a few nested mirrors in other projects)
• Manufacturing of Wolter I system needs very expensive mandrels (3D aspheric)
• Manufacturing of KB system can be easier and cheaper (2D aspheric)
• Substrates can be glass and/or silicon with excellent flatness and micro-roughness which is necessary for long-focal optics
AXRO December 2012 2
Wolter system
• Double reflection X-ray optics • Rotationally symmetric mirrors of parabolic
and hyperbolic shape• Set of nested mirrors is arranged
concentrically to the optical axis• Each ray is reflected at the parabolic
surface first, then at the hyperbolic surface• Quality of the focal spot depends on
quality of substrates (shape, microroughness)
• Optical error is rectified (astigmatic and coma error)
• Replicated technology requires expensive mandrels
XMM
http://imagine.gsfc.nasa.gov
AXRO December 2012 3
horizontal focusing mirror
vertical focusing mirror
Kirkpatrick-Baez system
• Double reflection X-ray Optics • Two mirror sets vertical and horizontal• Mirrors in both sets have to be curved
parabolically • Single focal point is formed in the
intersection of the horizontal and vertical focal planes
• Quality of the focal spot depends on quality of substrates (shape, microroughness)
• Technology is not necessarily based on precise and expensive mandrel
• Classical manufacturing technology of laboratory KB optics is expensive
http://imagine.gsfc.nasa.gov/
http://www.x-ray-optics.de
AXRO December 2012 4
Apertures for ray-tracing simulation
AXRO December 2012 5
Wolter I Kirkpatrick-Baez
• Comparison of aperture sizes of W and KB systems
• Diameter of Wolter 2 m, KB aperture 2 × 2 m
• Similar reflection angle considered
• Reflectivity of edge mirror 70% (for energy 1 keV)
AXRO December 2012 6
KB W
Type of optics Parabolic-parabolic planarParabolic-hyperbolic
rotational
Number of reflections
2 2
Focal length - Aperture
20 m – 913 x 913 mm40 m – 1826 x 1826 mm
10 m – radius 913 mm20 m – radius 1826 mm
First mirror134 mm from axis268 mm from axis
134 mm from axis268 mm from axis
Number of mirrors420 840
394 788
Length of substrate 300 mm 300 mm
Material substrate silicon glass
Surface gold gold
Ray-tracing simulations
Large X-ray telescope composed of modules
Sunflower configuration uses Fibonacci numbers (the lines from the centre to the corner of each module indicate the direction in
which 2-reflection rays are deflected)
Radial packing of modules used for the
Wolter I design
The simple cartesian packing used as an alternative to the
sunflower tessellation for the KB design
Radial design Cartesian design Sunflower design
The design, manufacture and predicted performance of Kirkpatrick-Baez Silicon stacks for the International X-ray Observatory or similar applications, Optics for EUV, X-ray and Gamma-ray Astronomy IV (Proc. of SPIE Vol.7437) Willingal and Spaan, 2009.
AXRO December 2012 7
Studied KB X-ray modules• Modules are assembled from
o thin reflection foils (Schmidt arrangement) or
o rectangular channels (Angel arrangement)
with precise shape and with low microroughness
AXRO December 2012 8
Novel design of X-ray optical KB Flower system (KBF)
• X-ray KBF optical system is assembled from minimally 5 segments (petals)
• Each segment (petal) is assembled from modules (one or more)
• Each module is assembled from
thin reflection foils or rectangular channels
• Energy range 50 eV – 10 keV (EUV, SXR, XR)
AXRO December 2012 9
X-ray segment of KBF system
• Segment is a sector of a circle with central angle 18°- 72° (usually 45°)
• Segment is assembled from modules
• Diagonals of all modules are parallel with symmetry axis of segment
• Black narrow area is nonfunctional area
AXRO December 2012 10
Design of KBF system
• X-ray optical system is assembled from segments (minimally 5)
• Symmetry axis of each segment intersects symmetry axis of the optical system
• Arrangement of segments approaches a circular aperture
• Patent pending (PV 2011-297)
AXRO December 2012 11
X-ray optical systems - apertures
Kirkpatrick-Baezsystem
Wolter systemFlower system
AXRO December 2012 12
• Size limited by the critical angle – the same maximum incident angle for all systems for 1 keV
(reflectivity 70% after 1st reflection, 50% after 2nd reflection)
• Wolter I and KB systems have the same aperture size
• KBF system has more than two times larger aperture than the others
X-ray optical systems - comparison
System Focal length(m)
Active aperture(m2)
Number of reflections
KB 20 2.6 2 (R = 50%)
W 10 2.6 2 (R = 50%)
KBF 20 5.6 2 (R = 50%)
P 20 2.6 1 (R = 70%)
AXRO December 2012 13
W – Wolter system, KB – Kirkpatrick-Baez system, KBF – KB Flower system, P – Parabolic system (“Wolter without hyperbolic part”)
• Focal length of KB, KBF and Parabolic system is two times larger than that of Wolter system
X-ray optical systems - comparison
KB – Kirkpatrick-Baez system
W – Wolter system
KBF - KB Flower system
P – Parabolic system
• 1 keV : KBFKBF(F=20m) > PP(F=20m) > WW(F=10m) > KBKB(F=20m)
• 10 keV : PP(F=20m) > WW(F=10m) ≥ KBFKBF(F=20m) > KBKB(F=20m)→ COMBINATION
AXRO December 2012 14
X-ray optical systems - comparison
=> COMBINATIONKBFKBF and PP
(in SXR - XR region)
logarithmic scale
AXRO December 2012 15
linear scale
Novel X-ray optical system KBF+P combination
• Non-functional (blind) central area of KBF system can be filled with thin rotationally symmetric foils (classical nested mirrors with parabolic shape P)
=> improvement of KBF optical system aperture effective area for higher
energies
• Patent pending (PV 2011-297)
AXRO December 2012 16
Advantages of KBF+P combination:
•KBF design has the largest effective aperture in SXR region
•KBF design allows higher efficiency in XR region using combination with parabolic mirrors filling the KBF non-functional area
•more homogeneous beam can be achieved by rotation of the whole optical system
•precise expensive mandrels are not needed for KBF part
•silicon or glass thin planar mirrors can be used in KBF part
AXRO December 2012 17
X-ray optical system KBF+P combination
Applications of KBF+P system
• Astrophysical application (X-ray telescopes)
• Laboratory application (EUV, XUV, SXR and XR optics)
• EUV /XUV microscopy and tomography
• EUV/XUV lithography
• X-ray Compton imaging
• Focusing of electrons and/or neutrons
• XRF analysis
AXRO December 2012 18
Experiments X-ray tests of KBF elements
• X-ray testing of astronomical long-focal optics requires parallel beam and long vacuum chambers, which makes testing rather difficult
• New testing method was proposed
• Testing is divided into two parts:
1. Testing of optics assembling technology and focusing properties in elliptic geometry (point-to-point imaging)
2. Application of verified optical technologies to final optics design with parabolic geometry
• KB modules were tested in vacuum chamber in Center for Astrophysics and Space Astronomy (CASA, University of Colorado at Boulder, USA)
AXRO December 2012 19
Testing vacuum chamber at CASA UC
• X-Ray source with Ti anode (Lα, 453 eV, 2.73 nm)
• X-Ray beam diameter(diameter of vacuum tube) 8 cm
• Total vacuum chamber length 20 m
• MCP detector, diameter 1’’
AXRO December 2012 20
Comparison of glass and Si mirrors
• 2 modules were assembled from glass mirrors and Si standard wafers
• Housing - Al profile
• Mirror size: 100 × 100 mm (glass), 100 × 75 mm (Si)
• Mirror thickness: 0.4 mm (glass), 0.7 mm (Si)
• Au surface coating
AXRO December 2012 21
AXRO December 2012 22
Comparison of glass and Si mirrorsSimulation and test results
Ray-tracing simulation(ideally flat mirrors considered)
X-ray tests at CASA CU
• Symmetric geometry, flat mirrors, focal length 9 m
• Glass module – vertical, Si module – horizontal
Comparison of glass and Si mirrors
AXRO December 2012 23
Taylor-Hobson profilometermodule RMS (μm) RMS (arcsec)
glass 1.6 ÷ 21.3 34.7 ÷ 279.4
Si 0.4 ÷ 0.6 12.1 ÷ 17.1
simulation measurementmodule FWHM (mm) FWHM (arcsec) FWHM (mm) FWHM (arcsec)
glass 0.46 2.6 6.14 35.2Si 0.36 2.1 1.54 8.8
• Mirrors were measured on Taylor-Hobson profilometer
• Si mirrors have better flatness
• High variance of glass mirrors
• Difference between simulation and experiment (broadening of focus) is caused by poor quality of glass mirrors
Comparison of glass and Si mirrors
AXRO December 2012 24
Figure error
Angular error
glass Si
Development of improved Si wafers for X-ray optics applications
AXRO December 2012 25
Standard wafer
Improved surface
•Standard silicon wafer (150 mm diameter):
- thickness in the wafer center: 628.81 µm,
minimal measured thickness: 630.40 µm,
maximal measured thickness: 632.50 µm, - total thickness variation: 2.10 µm, flatness: 1.76
µm
•Highly flat silicon wafer developed for sub-micron technologies in ON Semiconductor Czech Republic
(150 mm diameter):
- thickness in the wafer center: 610.92 µm,
minimal measured thickness: 610.58 µm,
maximal measured thickness: 611.03 µm,- total thickness variation: 0.45 µm, flatness: 0.29
µm improvement by factor of 5!
KB modules - specification
• 144 commercially available 525 μm thick Si wafers with Au surface coating
• 1st mirror is at a distance of approx. 16 mm from optical axis
• Mirrors arranged into planar-ellipsoidal shape with axial symmetry
• Mirror size 100 × 100 mm
• 3 sets of 24 (18+6) mirrors in each module
• Spacing 1.5 ÷ 2.5 mm
AXRO December 2012 26
Experimental arrangement
• Modules were designed for vacuum chamber at CASA (Univ. of Colorado)
• Point-to-point imaging - elliptical geometry
• Source to optics distance: 10 m
• Optics to detector distance: 8 m
• Distance between modules: 10 cm
• Module position adjustment donewith visible light (Xe lamp)
AXRO December 2012 27
Test results
• FWHM = 1.63 mm
• Anglular resolution: 10.2 arcsec (after ellips. correction)
AXRO December 2012 28
Ray-tracing simulations
Input parameters (mirror material properties, arrangement of mirrors in modules, experiment geometry, …) are the same as in the experiment
AXRO December 2012 29
Theoretical focus:FWHM = 0.58 mm
≈ 3.7 arcsec
Theoretical focus with 0.2 mm source diameter and 2 μm manufacturing errors:
FWHM = 0.59 mm
Optics with piezoelements
• Piezoelements were studied in order to improve resolution
• Glued striped piezoelements enable mirrors bending which approximates aspherical shape of KB mirror
• Two stacked mirrors (optical surfaces) were tested in vacuum chamber
• Mirror size 100 × 55 mm
• Distance of mirrors from optical axis - 40 cm
• Mirrors bent to radius 250 m
AXRO December 2012 30
• Focus behavior depending on piezoelement voltages was studied
• Voltage for optimum focus was found
AXRO December 2012 31
Optics with piezoelements
• Joint focus of two mirrors with piezoelements obtained
• FWHM = 1.35 mm
• Anglular resolution: 7 arcsec (after correction)
AXRO December 2012 32
Optics with piezoelementsTest results
Conclusion
• X-ray optical system based on Kirkpatrick-Baez modules in novel arrangement (KBF) and its combination with nested parabolic mirrors in the KBF center area were studied
• Proposed system has better light efficiency in comparison with relevant KB and Wolter X-ray optical systems
• Commercial Si wafers can be effectively used in KBF part, which was experimentally verified within X-ray testing at CASA (University of Colorado)
• Potential of active optics for resolution improvement was demonstrated• Novel KBF system can be used for astrophysical applications as well as for
laboratory applications (focusing and imaging in EUV, SXR and XR) • Patent pending of KBF design and combination KBF+P (PV 2011-297)
AXRO December 2012 33
Aknowledgements
• Ministry of Education, Youth and Sports of the Czech Republic, project ME09028 and ME09004
• Team of Prof. Webster Cash, University of Colorado at Boulder• ESA PECS Project No. 98039• MEYS ESF Project CZ.1.07/2.3.00/20.0092• Drs. J. Sik and M. Lorenc from ON Semiconductor Czech Republic
AXRO December 2012 34
THANK YOU FOR ATTENTION
AXRO December 2012 35
Prague