Notes: 1. SYSTEM WEIGHT: 3,802 LBS....c 4.01 d 46.88 c&d 3.14 47.00 8.75 61.89 i 45.75 t 23.75 t...

1
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 A A B B C C D D 1 of 1 D Sheet Date: Revised: Date: Drawn: DOCUMENT DO NOT SCALE THIS Scale: Description: GENERAL ASSEMBLY 7.5HP QX LAB LUBE VAC SPC 200G RECEIVER MDB 06/20/2019 MDB 11/20/2017 BEACONMEDÆS 4107 8562 94 Part Number: Rev: 01 DN: BM190347 This drawing and the information contained thereon remain the property of BeaconMedaes and may not be used for other than the purpose for which it is loaned without the expressed written permission from BeaconMedaes Engineering. Notes: 1. SYSTEM WEIGHT: 3,802 LBS. 2. INDICATES LIFTING POINT. 3. DENOTES CENTER OF GRAVITY. Form F-007 Rev. 01 200 GALLON RECEIVER RECEIVER BYPASS VALVE INLET 3" FLANGE INTEGRATED LIFTING EYES MINIMUM CLEARANCE FOR MAINTENANCE & VENTILATION SYSTEM CONNECTIONS ID DESCRIPTION I INLET LOCATION D DISCHARGE LOCATION C CONDENSATE DRAIN LOCATION T TANK DRAIN LOCATION DISCHARGE 2" FLANGE (2 PLACES) 1.50 25.50 (TYP) 10.75 32.00 2.75 9.25 28.50 24.00 24.00 36.00 24.00 28.50 (TYP) 8.00 34.50 99.50 102.29 84.22 4.01 C 46.88 D 47.00 8.75 3.14 C&D 61.89 45.75 I 23.75 T 7.86 T 57.29 T 50.76 27.80 23.33 0.75 BOLTDOWNS (12 PLACES) ELECTRICAL CONNECTION INTAKE FILTER PER PUMP AIR PURGE INLET FILTER PER PUMP 28.29 C & D 99.29 C & D MANUAL DRAIN 1/2" FNPT PUMP ISOLATION VALVE WITH 24VDC ACTUATOR PER PUMP CONTROL CABINET MANUAL CONDENSATE DRAIN,TYP

Transcript of Notes: 1. SYSTEM WEIGHT: 3,802 LBS....c 4.01 d 46.88 c&d 3.14 47.00 8.75 61.89 i 45.75 t 23.75 t...

Page 1: Notes: 1. SYSTEM WEIGHT: 3,802 LBS....c 4.01 d 46.88 c&d 3.14 47.00 8.75 61.89 i 45.75 t 23.75 t 7.86 t 57.29 50.76 27.80 23.33 0.75 boltdowns (12 places) electrical connection intake

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A A

B B

C C

D D

1 of 1

D

Sheet

Date:Revised: Date: Drawn:

DOCUMENTDO NOT SCALE THIS

Scale:

Description:

GENERAL ASSEMBLY 7.5HP QX LABLUBE VAC SPC 200G RECEIVER

MDB 06/20/2019 MDB 11/20/2017

BEACONMEDÆS

4107 8562 94Part Number:

Rev:01

DN:BM190347

This drawing and the information contained thereon remain the property of BeaconMedaes and may not be used for other than the purpose for which it is loaned without the expressed written permission from BeaconMedaes Engineering.

Notes: 1. SYSTEM WEIGHT: 3,802 LBS. 2. INDICATES LIFTING POINT. 3. DENOTES CENTER OF GRAVITY.

Form F-007 Rev. 01

200 GALLONRECEIVER

RECEIVERBYPASSVALVE

INLET3" FLANGE

INTEGRATEDLIFTING EYES

MINIMUM CLEARANCE FORMAINTENANCE & VENTILATION

SYSTEM CONNECTIONSID DESCRIPTIONI INLET LOCATIOND DISCHARGE LOCATIONC CONDENSATE DRAIN

LOCATIONT TANK DRAIN LOCATION

DISCHARGE2" FLANGE(2 PLACES)

1.50 25.50 (TYP) 10.75 32.00 2.75

9.25

28.50

24.00

24.00

36.00

24.00

28.50 (TYP)

8.00 34.50

99.50

102.29

84.22

4.01C

46.88D

47.00 8.753.14C&D

61.89

45.75I

23.75T

7.86T

57.29T50.76

27.80

23.33

0.75 BOLTDOWNS(12 PLACES)

ELECTRICALCONNECTION

INTAKE FILTER PER PUMP

AIR PURGE INLET FILTER PER PUMP

28.29C & D

99.29C & D

MANUAL DRAIN1/2" FNPT

PUMP ISOLATION VALVEWITH 24VDC ACTUATORPER PUMP

CONTROL CABINET

MANUALCONDENSATEDRAIN,TYP