Note: of the products, make sure that you Set Up · of the products, make sure that you read the...

2
Note: To ensure correct and safe use of the products, make sure that you read the Operating Instructions on the DVD carefully. Set Up Installing the actiCAP software: 1 Plug in the USB stick and open the installation menu via double click on autorun.exe. Important: Please make sure to respect the physical channel order when connecting electrode sets. Before connecting or disconnecting any electrode set (step 2 and 3) make sure that the actiCAP ControlBox is switched OFF. 2 Ch. 97-128 Splitter Box Ch. 65-96 Splitter Box Ch. 33-64 Splitter Box Ch. 1-32 Splitter Box Ch. 1-32 Amplifier Ch. 33-64 Amplifier Ch. 65-96 Amplifier Ch. 97-128 Amplifier Use the flat ribbon cable to connect the actiCAP ControlBox to the amplifier. Then connect each splitter box to the correspondent connector on the ControlBox. ControlBox splitter box ribbon cable 1 - 32 channels 33 - 64 channels 65 - 96 channels 97 - 128 channels green ports yellow ports red ports white ports 3 Connect the GND and REF electrode to the ControlBox GND use with actiCap only! REF aC- er1 Installation of the actiCAP drivers 4 Remove the battery cover on the rear side of the ControlBox. Then use the actiCAP USB cable to connect the ControlBox to the computer. Windows will install the driver automatically. computer‘s USB 2 port Warnings: Do not pull the cables when removing the electrodes from the cap. Use the actiCAP removal tool to remove the electrodes from the holder. The splitter box must not come into contact with water. How to prepare 64 actiCAP electrodes in 10 minutes: I. Inject the gel starting with the GND and REF channels II. Gently rub the skin by rotating the syringe a few times. This rotation spreads the gel evenly over the skin and increases the contact area to a sufficient degree. 5

Transcript of Note: of the products, make sure that you Set Up · of the products, make sure that you read the...

Note: To ensure correct and safe use of the products, make sure that you read the Operating Instructions on the DVD carefully.

Adhere to manualSuivez les instructions

du manuel

Set Up

Installing the actiCAP software: 1

Plug in the USB stick and open the installation menu via double click on autorun.exe.

Important: Please make sure to respect the physical channel order when connecting electrode sets.Before connecting or disconnecting any electrode set (step 2 and 3) make sure that the actiCAP ControlBox is switched OFF.

2

Ch. 97-128 Splitter Box

Ch. 65-96 Splitter Box

Ch. 33-64 Splitter Box

Ch. 1-32 Splitter Box

Ch. 1-32 Amplifier

Ch. 33-64 Amplifier

Ch. 65-96 Amplifier

Ch. 97-128 Amplifier

Use the flat ribbon cable to connect the actiCAP ControlBox to the amplifier. Then connect each splitter box to the correspondent connector on the ControlBox.

ControlBox

splitter box

ribbon cable 1 - 32 channels33 - 64 channels 65 - 96 channels 97 - 128 channels

green ports yellow portsred ports white ports

3 Connect the GND and REF electrode to the ControlBox

GND

use with actiCap only!

REF

aC- er1

Installation of the actiCAP drivers4

Remove the battery cover on the rear side of the ControlBox. Then use the actiCAP USB cable to connect the ControlBox to the computer. Windows will install the driver automatically.

computer‘s USB 2 port

Warnings:

Do not pull the cables when removing the electrodes from the cap. Use the actiCAP removal tool to remove the electrodes from the holder.

The splitter box must not come into contact with water.

How to prepare 64 actiCAP electrodes in 10 minutes: I. Inject the gel starting with the GND and REF channelsII. Gently rub the skin by rotating the syringe a few times. This rotation spreads the gel evenly over the skin and increases the contact area to a sufficient degree.

5

Set Up YouractiCAP

Brain Products GmbH

Zeppelinstrasse 7

82205 Gilching

Germany

T +49 (0) 8105 733 84 0

F +49 (0) 8105 733 84 505

[email protected]

Worldwide Caution:Our products are scientific equipment

for INVESTIGATIONAL USE ONLY!

Medical use e.g. for diagnosis, treatment of disease

or other such purposes is strictly forbidden.

Version 009 11/2017© Brain Products GmbH