NORTH - gov.je and transport...3.15m x 1.20m Bus shelter (green) 100mm Gap for maintenance New...

1
LP LP LP NORTH La Route de Saint-Aubin Coronation Park BUS LP La Route de Saint-Aubin BUS 1 11.76 11.60 11.67 11.86 11.77 11.70 11.91 11.82 11 3.15m x 1.20m Bus shelter (green) 100mm Gap for maintenance New cantilever bus shelter installed in position shown and in accordance with specification. Footpath width unaltered 3150 1470 1200 3150 1300 1300 New boundary wall constructed around bus shelter. 2000 Consider moving bus stop cage 2.0m east to stop vehicles overtaking. New prefabricated bus shelter in accordance with manufacturers details 3150 West Elevation 2500 Bus stop markings relocated to new shelter position New prefabricated bus shelter in accordance with manufacturers details South Elevation Footpath La Route de Saint-Aubin New prefabricated bus shelter in accordance with manufacturers details 1350 East Elevation 1000 New prefabricated bus shelter in accordance with manufacturers details North Elevation Footpath 3 Bay Fully Enclosed Bus Shelter Specification: Description: Domed Roof / Open Front / Glazed Rear Dimensions: 1200mm Wide x 1350mm Long x 2500mm High Seating: Perch Seating Length of Shelter/ 700mm from Ground Level Glazing: Roof - Bronze Tinted Polycarbonate Colour: Dark Green framing 2500 1470 2500 1200 1200 La Route de Saint-Aubin All dimensions are to be checked on site before the commencement of any works including the order of materials. Any discrepancies are to be reported to the Architect. Do not scale from this drawing. Unless the title 'Contract' or 'Working' has been added to these drawings then these drawings are not for site use and we will accept no responsibility for errors or omissions, the drawing will also not be adjusted to include for SER requirements. This drawing is design copyright © Andrew Harvey Architects Ltd. Digimap Licence Number J48. Portions of this drawing may include intellectual property of the States of Jersey and are herein used by permission. Date: Rev: Revision Note: revision drawing number: 1st Floor, Beresford House, Bellozanne Road, St. Helier, Jersey, JE2 3JW mobile: 07797 740530 [email protected] Andrew Harvey Architects telephone: 01534 869291 facsimile: 01534 869293 scale(s): date: drawn: checked: client project title drawing title States of Jersey Property Holdings Proposed Bus Stop at Coronation Park La Route de Saint-Aubin St. Lawrence Proposed Site Plan, Elevations, Plan and Photo's 1:50 / 100 @ A1 Apr 2018 R.S 1310 / 04 / 01 1 0m LINEAR SCALE 1:50 2 3 4 5 4 0m LINEAR SCALE 1:100 8 20 10 2 6 12 14 16 18

Transcript of NORTH - gov.je and transport...3.15m x 1.20m Bus shelter (green) 100mm Gap for maintenance New...

Page 1: NORTH - gov.je and transport...3.15m x 1.20m Bus shelter (green) 100mm Gap for maintenance New cantilever bus shelter installed in position shown and in accordance with specification.

LP

LP

LP

NORTH

La Route de Saint-Aubin

Coronation Park

BU

S

LP

La Route de Saint-Aubin

BUS

11.75

11.76

11.60

11.67

11.86

11.77

11.70

11.91

11.82

11.90

3.15m x 1.20m Bus shelter (green)

100mm Gap for maintenance

New cantilever

bus shelter

installed in

position shown

and in

accordance

with

specification.

Footpath width unaltered

3150

1470

1200

3150

1300

1300

New boundary

wall

constructed

around bus

shelter.

2000

Consider

moving bus

stop cage 2.0m

east to stop

vehicles

overtaking.

New prefabricated bus

shelter in accordance

with manufacturers

details

3150

West Elevation

25

00

Bus stop markings

relocated to new

shelter position

New prefabricated bus

shelter in accordance

with manufacturers

details

South Elevation

Footpath

La Route de Saint-Aubin

New prefabricated bus

shelter in accordance

with manufacturers

details

1350

East Elevation

10

00

New prefabricated

bus shelter in

accordance with

manufacturers

details

North Elevation

Footpath

3 Bay Fully Enclosed Bus Shelter

Specification:

Description:

Domed Roof / Open Front / Glazed Rear

Dimensions:

1200mm Wide x 1350mm Long x 2500mm High

Seating:

Perch Seating Length of Shelter/ 700mm from

Ground Level

Glazing:

Roof - Bronze Tinted Polycarbonate

Colour:

Dark Green framing

2500

1470

2500

1200

1200

La Route de Saint-Aubin

All dimensions are to be checked on site before the

commencement of any works including the order of materials.

Any discrepancies are to be reported to the Architect.

Do not scale from this drawing.

Unless the title 'Contract' or 'Working' has been added to these

drawings then these drawings are not for site use and we will

accept no responsibility for errors or omissions, the drawing will

also not be adjusted to include for SER requirements.

This drawing is design copyright © Andrew Harvey Architects Ltd.

Digimap Licence Number J48.

Portions of this drawing may include intellectual property of the

States of Jersey and are herein used by permission.

Date:Rev: Revision Note:

revision

drawing number:

1st Floor, Beresford House, Bellozanne Road,

St. Helier, Jersey, JE2 3JW

mobile: 07797 740530

[email protected]

Andrew Harvey Architects

telephone: 01534 869291

facsimile: 01534 869293

scale(s):

date: drawn: checked:

client

project title

drawing title

States of Jersey

Property Holdings

Proposed Bus Stop at

Coronation Park

La Route de Saint-Aubin

St. Lawrence

Proposed Site Plan,

Elevations, Plan and

Photo's

1:50 / 100 @ A1 Apr 2018 R.S

1310 / 04 / 01

10m

LINEAR SCALE 1:50

2 3 4 5

40m

LINEAR SCALE 1:100

8 20102 6 12 14 16 18

AutoCAD SHX Text
3437
AutoCAD SHX Text
3437