NORM YENI ARGE FLYER R4 - NORM CIVATA · for more information: Norm-iFR Developed thread form to...
Transcript of NORM YENI ARGE FLYER R4 - NORM CIVATA · for more information: Norm-iFR Developed thread form to...
for more information:
Norm-iFR
Developed thread form to improve fatigue resistance of bolt
Same static strength withstandard bolt
Same breaking torque withstandard bolt
Easily used with standard threaded nuts
10007 Sk. No: 1/1 A.O.S.B. Çiğli-İZMİR TurkeyTel: +90 232 376 76 10 Faks: +90 232 376 76 13
Improved Fatigue Resistance
Norm - iFR vs Standard BoltM8x1.25 DIN 933 8.8 PN
Force Amplitude (kN)
Ratio
of A
vera
ge F
atiq
ue L
ife (C
ycle
)(N
orm
-iFR
/ Sta
ndar
d Bo
lt)
2,0
1,8
1,6
1,4
1,2
1,0
0,8
0,6
0,4
0,2
0,0
3 3.5 5.36
1,761,48
1,08
Wohler Curve Comparison
Standart Bolt Vs Norm-iFRM8x1.25 DIN 933 8.8 PN Bolt
Cycle (x1000)
Fa (k
N)
IMPROVED FATIGUERESISTANCE
Fm=21.1 kNTesting Machine: Zwick Amsler 250 HFP 5100Loading Condition: Axial (Tension-Tansion)Test Frequency= 75 HzReplication= %83.3 accord. ASTM E73995% Confidence Interval accord. ASTM E739
2
3
4
5
6
100 1000 10000
10081436
2.6 kN
Norm - iFR
P=%50P=%50
StandartBolt
TEST andAPPLICATION CENTER
Perthometer
Profile Projection
Video Projection
Spectrometer
Mechanical & Statical Testers
Optical Microscopes
Stereo - zoom Microscopes
Molding, Cu�ing andPolishing Equipments
Thermal Camera
Hardness Measurement Testers
Coordinate MeasuringMachine (CMM)
Fatigue Tester
Bi - axial Vibration Tester
Torque - Tension Tester
for more information: