Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
TABLE OF CONTENTS
1 INTRODUCTION 3
1.1 General 3 1.2 Scope of study 3 1.3 Noise Immission limits 4 1.3.1 World Bank 4 1.3.2 World Health Organisation 5 1.3.3 Greek national noise limits 5 1.3.4 Project Specification 6 1.3.5 Summary 6
2 DOCUMENTATION USED 7
3 STANDARDS AND GUIDELINES USED 7
4 SITE DESCRIPTION 8
4.1 Local Situation, Sensitive Receptor Points 8 4.2 Proposed Gas Compressor Station 9
5 NOISE MODELLING 10
5.1 Methodology 10 5.2 Meteorological conditions considered 10
6 NOISE CONTROL SPECIFICATIONS AND ASSOCITATED NOISE CONTROL MEASURES (NCM) 11
7 PREDICTED NOISE LEVELS 17
8 CONCLUSION 19
GLOSSARY OF TERMS 20
ATTACHMENTS 21
Page 3 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
1 INTRODUCTION
1.1 General
The TAP AG proposes to develop the Trans Adriatic Pipeline to transport natural gas from the
Middle East Area via Greece, Albania and across the Adriatic Sea to southern Italy.
The pipeline transport capacity will be initially approx. 10 billion cubic meters / year. It is planned
to develop the initial transport capacity at a later stage up to an ultimate transport capacity of 20
billion cubic meters / year. In order to provide this gas capacity a gas compressor facility in
central Greece at district Central Macedonia is needed among other stations.
Genest und Partner Ingenieurgesellschaft mbH was commissioned by E.ON New Build & Tech-
nology GmbH to undertake a noise modelling study of the proposed gas compressor station
GCS01 (Location Alternative D) at the regional unit Central Macedonia, Greek. The study will
form part of an Environmental Impact Assessment for the site and is therefore based on the
future ultimate gas transport capacity of 20 BCM/Y.
In this report, all necessary noise control measures for the proposed gas compressor station
GCS01 will be specified to comply with various noise limits, which are discussed later in this
report under section 1.3.
1.2 Scope of study
The task of this study is to identify noise mitigation options in plant selection and design in order
to achieve compliance with the governmental noise level requirements. As a first step a
preliminary estimate for the noise emission and the necessary mitigation measures should be
prepared.
The following list outlines the major activities undertaken during the course of the noise impact
assessment.
Page 4 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
Review of documentation provided by E.ON New Build & Technology GmbH including
Data Site & Utility Data, site plans and topographical data.
Estimation of noise emission levels (sound power levels) for equipment associated with
the proposed operation.
Development of an acoustic model for the proposed compressor station and the
surrounding area.
Calculation of noise levels at sensitive receptors using the noise prediction method
described in ISO 9613 ‘Acoustics – Attenuation of sound during propagation outdoors –
Part 2: General method of calculation’ for the meteorological conditions provided by ENT.
The acoustic model shall only consider continuous and discontinuous noise sources during
normal operation of the plant.
The following noise sources are to be excluded from the modelling and determination of the
predicted sound pressure level:
Construction, pre-commissioning and commissioning noise emissions
Maintenance activity like vehicle road noise, crane movements etc.
1.3 Noise Immission limits
Currently there are no statutory regulations governing environmental noise immissions in the
surrounding area of the proposed compressor station. Several criteria are therefore discussed
below to provide information of international standards.
1.3.1 World Bank
In the ‘Pollution Prevention and Abatement Handbook’ issued by the World Bank Group in April
1999 (Permanent URL: http://go.worldbank.org/E6G093QFZ1), noise limits for new installations
financed by the World Bank are set out, which are summarized below in Table 1.
Additionally, it is stated in the handbook that an increase of up to 3 dB above the existing
background noise levels at receptors outside the property boundary is considered acceptable.
Page 5 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
Table 1: World Bank noise limits, maximum LAeq in dB(A)
Receptor Day
(07:00 – 22:00) Night
(22:00 – 07:00)
Residential, institutional, educational 55 45
Industrial, commercial 70 70
1.3.2 World Health Organisation
In the WHO document „Guidelines for Community Noise‘, guideline limit values for community
noise in various specific environments are provided. Noise levels below the limits are considered
necessary to minimize any temporary or long term deterioration in physical, psychological or
social functioning associated with noise exposure. The values form the basis of many
international environmental noise policy limits and are summarized in Table 2 below.
Table 2: WHO Guideline values
Specific Environment Critical Health Effects LAeq
dB(A) LAmax
dB(A)
Outdoor living area Serious annoyance, daytime and evening
Moderate annoyance, daytime and evening
55
50
Inside bedrooms Sleep disturbance, night-time 30 45
Outside bedrooms Sleep disturbance, window open (outdoor
values) 45 60
School, playground outdoor Annoyance (external source) 55
Industrial, commercial,
shopping and traffic areas,
indoors and Outdoors
Hearing impairment 70 110
1.3.3 Greek national noise limits
The main legal framework is provided under art. 14 of the Environmental Protection Act 1985,
Presidential Decree 1180/1981. The herein mentioned noise limits apply at the borderline of a
plot area, according to land use in the surrounding area (urban, semi-urban, industrial, mixed).
The part of the borderline oriented to the emission source is relevant. The noise limits in this
instruction are listed in the table below and correspond with the noise limits set out by the WHO:
Page 6 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
Table 3: Immission noise limits according to Greek legislation (Presidential Decree 1180/1981, Table 1)
Line Description Noise limits LAeq in dB(A)
1 Established industrial areas 70
2 Areas with predominantly industrial
characteristics 65
3 Areas with equivalent industrial and urban
characteristics 55
4 Areas with predominantly urban
characteristics 50
In cases where the noise emitting site borders on an home property, the noise limit is 45 dB(A),
measured in front of an open door or window.
1.3.4 Project Specification
Until further notice, the noise limits within this project will be set to LAeq ≤ 65 dB(A) at the station
fence measured as hourly averaged noise level.
1.3.5 Summary
The ‘3 dB(A) Criterion’ demanded by the World Bank Group is the most strict requirement
concerning noise, (please see also section 1.3.1). Consequently the maximum noise impacts
emitted from the proposed compressor station should not increase the background noise level of
3 dB(A) at the nearest receptor location off-site.
Page 7 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
2 DOCUMENTATION USED
Specification Noise Survey
Document No.: CAL00-ENT-000-A-TSA-0001, Rev.: 01
Project Manual – Part 12 – Document Control
Document No.: CAL00 – ENT-000-B-TPA-0012, Rev.: 0D
Project Manual – Part 16 – Engineering Manual
Document No.: CAL00-ENT-000-B-TPA-0016, Rev.: 0C
Station Layout GCS01 – Gas Compressor Station Serres
GCS01-ENT-000-Q-DQA-0009 (draft-version for location alternative D)
3 STANDARDS AND GUIDELINES USED
DIN EN 12354-4 „Building acoustics – Estimation of acoustic performance of buildings from the performance of products Part 4: Transmission of indoor sound to the outside“, Issue date: 2001-04
VDI 3733 „Noise at pipes“ Issue date: 1996-07
VDI 3734 Part 1
„Characteristic noise emission values of technical sound sources; air coolers“ Issue date: 1981-02
DIN ISO 9613 Part 2
Acoustics - „Attenuation of sound during propagation outdoors, Part 2: General method of calculation“ Issue date: 1999-10
Page 8 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
4 SITE DESCRIPTION
4.1 Local Situation, Sensitive Receptor Points
The Gas Compressor Station is proposed for a site within the district Central Macedonia, Greece.
The local situation can be seen from the aerial image below.
The area is a primarily rural area. The closest residences to the site are settlements north-east of
and west of the station.
The shortest distance between the proposed compressor station and single dwellings is in the
north-west direction, with a distance of approx. 1950 m to the geometrical centre of the station.
Picture 1: Aerial image of the proposed compressor station GCS01 – Location Alternative D
Page 9 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
Table 4: Noise sensitive receptors
Sensitive receptor point Distance / Direction
1 Krinos
nearest outskirt of village
approx. 1950 m
2 Konstantinato
nearest outskirt of village
approx. 2050 m
3 Neochori
nearest outskirt of village approx. 2350 m
4 Station fence
West of the station approx. 200 m
north-west
5 Station fence
South of the station approx. 200 m
south-west
6 Station fence
East of the station approx. 200 m
south-east
4.2 Proposed Gas Compressor Station
Five gas turbines, each with a power of 25 MW, will be installed of which four units will be in
operation simultaneously at full load. One compressor unit is reserved for standby. Each gas
compressor unit comprises one natural gas compressor with a gas turbine driver and will be
located within its own compressor building.
The compressor buildings will be a solid construction (concrete walls or brick walls) with sound
proof doors and air ventilation systems. The combustion air intake filter equipment and the
exhaust ducts and stacks will be located outside, adjacent to the compressor building. It is
assumed that the gas turbine driver will be equipped with an additional enclosure.
Two gas coolers, each equipped with 10 low noise fans and one recycle cooler with four fans will
be located to the South of the compressor buildings. The area between the compressor buildings
and the gas coolers is reserved for the pipe work. Piping, which is located above ground, must be
equipped with a sound proof cladding. The construction of compressor station GCS01 is
necessary to realise the final development stage of the pipeline gas transport capacity of
20 BCM/Y.
Page 10 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
5 NOISE MODELLING
5.1 Methodology
In order to determine the extent of noise emission from the proposed site a 3D computer noise
model has been developed. The model was developed using the prediction software
‚SoundPLAN, Version 7.1‘ in conjunction with topographic information supplied in digital form.
The significant noise sources were built in the model at the locations obtained from the provided
plot plans.
The noise predictions have been performed according to ISO 9613-2. The method incorporates
the influence of geometrical divergence, ground absorption, atmospheric absorption (in
accordance with ISO 9613-1), shielding (barrier) attenuation and meteorological conditions.
For the noise assessment of the planned compressor station, sound power data from Section 6
were used, assuming the scenario of normal operation mode for the final development phase.
According to ISO 9613-2, Table 5, the accuracy of the model is within a range of ± 3 dB.
5.2 Meteorological conditions considered
The noise model has been based on the following meteorological conditions which need to be
verified during detail engineering phase:
Table 5: Meteorological conditions considered in the noise model
Temperature (°C) Relative
Humidity (%)
Barometric
Pressure (hPa)
Wind Speed and Direction
15 70 1015 ≈ 2 m/s North-West
Cmet was generally set to zero. No vegetation was considered within the noise model. The ground
beneath the noise sources were modelled as fully reflective (ground absorption zero). Outside of
the proposed compressor station the ground was considered as agriculturally used area with a
ground absorption factor 0.85.
Page 11 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
6 NOISE CONTROL SPECIFICATIONS AND ASSOCITATED NOISE CONTROL MEASURES (NCM)
The following outlines the source sound power levels to be associated with the major noise
emitting equipment at the proposed site:
Table 6: Noise Specifications
Exhaust stack opening per unit, including stack surface LWA ≤ 88 dB(A)
NCM:
Exhaust silencer with staggered splitters
Exhaust duct outside compressor building, per unit LWA ≤ 85 dB(A)
NCM:
Sound proof cladding
Filter house, combustion air intake, per unit LWA ≤ 78 dB(A)
NCM:
Air intake silencer with staggered splitters
Air intake duct outside compressor building, per unit LWA ≤ 78 dB(A)
NCM:
Sound proof cladding
Turbine enclosure ventilation inlet, per unit LWA ≤ 76 dB(A)
NCM:
Inlet silencer
Turbine enclosure ventilation outlet, per unit LWA ≤ 76 dB(A)
NCM:
Outlet silencer
Oil cooler outside compressor building, per unit LWA ≤ 90 dB(A)
NCM:
To be guaranteed by the supplier
Page 12 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
Oil mist separator outlet, per unit LWA ≤ 78 dB(A)
NCM:
To be guaranteed by the supplier
Gas compressor unit inside compressor building
for one unit LWA ≤ 110 dB(A)
NCM:
To be guaranteed by the supplier
(enclosed gas turbine package).
100 mm sound proof cladding of gas pipes inside
the compressor building.
Resulting sound pressure level inside the building,
averaged: LpA approx. 94 dB(A)
Compressor building
Walls R’w ≥ 48 dB
NCM:
Concrete or brickwork, m ≥ 280 kg/m²
Roof R’w ≥ 45 dB
NCM:
Concrete, m ≥ 210 kg/m², plus thermal insulation
Explosion relief panel,
as part of the roof and walls of each compressor building R’w ≥ 16 dB
NCM:
To be guaranteed by the supplier
Doors, in situ R’w ≥ 30 dB
NCM:
To be guaranteed by the supplier
Building ventilation inlet, per opening
(four per building assumed) LWA ≤ 67 dB(A)
NCM:
Air inlet silencers with staggered splitters
Building ventilation outlet on roof, per unit
(four per building assumed) LWA ≤ 84 dB(A)
NCM:
To be guaranteed by the supplier
Page 13 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
Gas cooler with 10 fans, per cooler
(two coolers considered) LWA ≤ 91 dB(A)
NCM:
To be guaranteed by the supplier
One Start-up cooler with 4 fans LWA ≤ 87 dB(A)
NCM:
To be guaranteed by the supplier
Gas flow noise within gas coolers, per cooler
(identical for the two gas cooler and the start-up cooler) LWA ≤ 91 dB(A)
NCM:
To be reviewed during detail engineering.
Gas cooler, vertical pipework, upstream LWA ≤ 77 dB(A) / m
NCM:
To be reviewed during detail engineering,
probably 100 mm sound proof cladding.
Gas cooler header, discharge side, above ground LWA ≤ 76 dB(A) / m
NCM:
To be reviewed during detail engineering,
probably 200 mm sound proof cladding.
Gas cooler, vertical pipework, downstream LWA ≤ 74 dB(A) / m
NCM:
To be reviewed during detail engineering,
probably 100 mm sound proof cladding.
Station inlet filter, per unit
(in total four filter assumed) LWA ≤ 75 dB(A)
NCM:
To be reviewed during detail engineering,
normally no action needed.
Meter run, per unit
(in total four parallel trains assumed) LWA ≤ 87 dB(A)
NCM:
To be reviewed during detail engineering,
probably 100 mm sound proof cladding.
Compressor piping outdoors, suction side of
compressor, per unit LWA ≤ 76 dB(A) / m
NCM:
To be reviewed during detail engineering,
probably 200 mm sound proof cladding.
Page 14 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
Compressor piping outdoors, discharge side of
compressor, per unit LWA ≤ 78 dB(A) / m
NCM:
To be reviewed during detail engineering,
probably 200 mm sound proof cladding.
Recycle valve, per unit LWA ≤ 85 dB(A)
NCM:
To be reviewed during detail engineering,
probably enclosed.
Header, suction side LWA ≤ 76 dB(A) / m
NCM:
To be reviewed during detail engineering.
Header, discharge side, above ground LWA ≤ 78 dB(A) / m
NCM:
To be reviewed during detail engineering,
probably 200 mm sound proof cladding.
Air compressor, per unit
Air intake
Room ventilation outlet
LWA ≤ 83 dB(A)
LWA ≤ 65 dB(A)
LWA ≤ 66 dB(A)
NCM:
Within Utility Building.
Silencers at intake and outlet
Boiler room (Heating)
Stack
Room ventilation, air intake
Room ventilation, outlet
LWA ≤ 76 dB(A)
LWA ≤ 70 dB(A)
LWA ≤ 70 dB(A)
NCM:
Within Utility Building.
probably silencers at intake and outlet
Fuel gas skid I and II
Building surface (walls, roof, door)
Room ventilation, intake
Room ventilation, outlet
LWA ≤ 64 dB(A)
LWA ≤ 66 dB(A)
LWA ≤ 66 dB(A)
NCM:
Solid or lightweight construction,
walls and roof R’w ≥ 37 dB
Door R’w ≥ 30 dB
Page 15 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
Power generation I and II (Gas)
Building surface (walls, roof, door)
Stack opening
Room ventilation, intake
Room ventilation, outlet
LWA ≤ 74 dB(A)
LWA ≤ 88 dB(A)
LWA ≤ 74 dB(A)
LWA ≤ 74 dB(A)
NCM:
Solid or lightweight construction,
walls and roof R’w ≥ 37 dB
Door R’w ≥ 30 dB
Main Power generation I and II (Diesel)
(in case of AC power failure)
Package surface (walls, roof, door)
Mean sound level at 1 m distance all package surfaces
Stack opening
LpA ≤ 85 dB(A)
LWA ≤ 88 dB(A)
NCM:
Sound pressure level to be guaranteed by the supplier,
Generator has to be installed into an insulating container
Emergency Power generation I and II (Diesel)
Building surface (walls, roof, door)
Stack opening
Room ventilation, intake
Room ventilation, outlet
Cooling Air inlet
LWA ≤ 78 dB(A)
LWA ≤ 88 dB(A)
LWA ≤ 80 dB(A)
LWA ≤ 70 dB(A)
LWA ≤ 81 dB(A)
NCM:
Generator will be installed into an insulating container
Administration Building, Electrical Building,
Workshop / Stores Building
It is assumed, that sound pressure levels inside these
buildings are usually not higher than
LpA = 85 dB(A)
NCM:
Solid or lightweight Building construction,
walls and roof R’w ≥ 37 dB
Doors R’w ≥ 30 dB
Ventilation openings (if necessary) LwA ≤ 75 dB(A)
Air condition units outdoors (6 assumed) LwA ≤ 85 dB(A)
Page 16 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
Optional
(instead of one turbine driven gas compressor):
Combined Cycle - Steam Turbine with gas compressor,
installed within a solid building
Average sound pressure inside turbine hall
Four heat recovery steam generator
One condensate Cooler
LpA 96 dB(A)
LWA 94 dB(A) / unit
LWA 93 dB(A)
NCM:
Solid or lightweight Building construction,
walls and roof R’w ≥ 48 dB
Large Door R’w ≥ 30 dB
Small Doors R’w ≥ 25 dB
Ventilation openings, air intake LwA ≤ 75 dB(A)
Ventilation openings, air outlet LwA ≤ 84 dB(A)
Additional remarks:
All specified sound power levels must be free of a tonal noise characteristic. A tonal characteristic
may exist if the sound pressure levels of two adjacent 1/3 octave bands differ by 5 dB or more.
Noise with a tonal characteristic may be produced by the gas compressors due to their blade
passing frequency. This subject should be reviewed during detail engineering phase for further
decisions.
Tonal noise characteristics are especially not acceptable at the Non Return Valves (NRV) or the
filter screens.
Due to the highest priority of environmental and safety aspects noise emissions during
emergency cases are likely not to be considered within an environmental impact study.
Nevertheless for the reason of engineering criticality assessment noise emissions of emergency
power generators are also considered in the present study. According to routinely necessary test
runs of Diesel Power Generators are regarded.
Page 17 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
7 PREDICTED NOISE LEVELS
Noise levels in the area surrounding the site have been predicted using SoundPlan 7.1 as
described in Section 5.1 above. The prediction software is well recognized and accepted for its
accuracy and validity.
The predicted noise levels at each receptor, based on the modelled data outlined in Section 6 are
summarized in Table 7 below.
Table 7: Plant operation noise at sensitive receptors (final development stage)
Sensitive
receptor
Initial noise level
at night time
in dB(A)
Additional Noise
level at night time
in dB(A)
Total Noise level
at night time
in dB(A)
Increase of
background noise
in dB(A)
1 Krinos 28.2 26.1 30.3 2.1
2 Konstantinato 28.2 25.6 30.1 1.9
3 Neochori 28.2 24.7 29.8 1.6
4 Station fence, west - 60.0
5 Station fence, south - 57.1
6 Station fence, east - 54.2
From the table above, it can be seen that noise levels will be approximately 19 dB(A) below the
45 dB(A) limit suggested by the World Bank, the WHO and the Greek legislation for outdoor
noise levels in residential areas during night time. Further, the predicted noise levels at the
station fence comply with the project specification outlined in Section 1.3.4.
The contribution of each individual noise source to the resulting total sound pressure level at the
sensitive receptors can be drawn from the numerical charts in Attachment 3. The noise contour
plot for the scenario modelled is shown in Attachment 4.
For the calculation of the resulting total noise level for the final developement stage for the
nearest receptor point, baseline measurements have been performed by GENEST in
February 27th 2013. The averaged value measured during nighttime (10 p.m. to 6 a.m.) was 36.4
dB(A) at sensitive receptor No. 2 ‘Konstantinato’. To guarantee a conservative approach instead
of the averaged value the quietest hour during nighttime is taken into account. For this reason the
Page 18 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
measured hourly value of 28.2 dB(A) is considered as background noise level not only for the
nearest sensitive receptor but also for sensitive receptors far-off.
As shown in the table above, the additional predicted noise levels at each receptor point, is less
than the initial noise level. From that it can be derived that the predicted noise-increase of the
proposed site lies within a range of 3 dB(A) for the final development phase.
Page 19 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
8 CONCLUSION
It is proposed to develop a gas compressor station GCS01 – Location Alternative D at the district
Central Macedonia, Greece. The final compressor station will comprise of 4+1 gas compressor
units along with the necessary auxiliary equipment as referred to in chapter 4.2.
To predict the noise impact in the surrounding area a 3D noise model was developed. The
prediction results in this report indicates that noise received at the closest residences at the
villages Krinos, Konstantinato and Neochori from the full capacity operation of the final
development stage of the proposed gas compressor site GCS01 shall be deemed to be complied
with the guidelines of the World Bank and the WHO at all times.
This will be achieved by noise control treatment to plant equipment as specified in Section 6.
This study comprises 21 pages and 4 Attachments.
Genest und Partner
Ingenieurgesellschaft mbH
Ludwigshafen/Rhein, March 7th 2013
Scherer/ Dr. Hunsmann
Page 20 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
GLOSSARY OF TERMS
Lp / LpA unweighted / A-weighted sound pressure level in dB / dB(A)
Lpi Sound pressure level inside of rooms or enclosures in dB / dB(A)
Leq / LAeq unweighted / A-weighted energy averaged noise from a source, equivalent
continuous sound pressure level over a given period in dB / dB(A)
LW / LWA unweighted / A-weighted sound power level in dB / dB(A)
L‘W Sound power level per unit (m or m²)
R‘w Sound transmission loss in dB
De Insertion loss in dB
S Area in m²
s Distance in m
K0 Solid angle index in dB
Adiv Attenuation by geometric divergence
Aatm Attenuation by atmospheric absorption
Agr Attenuation by ground effect
Abar Attenuation by barrier or screening
Amisc Attenuation by miscellaneous effects
Cmet Meteorological correction
dLrefl Increase of noise by reflection
Page 21 of 21 Area Code
Comp. Code
System Code
Disc. Code
Doc.- Type
Ser. No.
Project Title: Trans Adriatic Pipeline – TAP GCS01-WGP-000-S-TRS-0002Rev.: 00 Document Title: Noise Control Study GCS01
ATTACHMENTS
Attachment 1: Topographical overview
Attachment 2: Station layout
Attachment 3: Detailed noise prediction results
Attachment 4: Noise contour plot
2 Konstantinato
1 Krinos
3 Neochori
6 Station Fence East
5 Station Fence South
4 Station Fence West
34713500
34713500
34714000
34714000
34714500
34714500
34715000
34715000
34715500
34715500
34716000
34716000
34716500
34716500
34717000
34717000
34717500
34717500
34718000
34718000
34718500
34718500
34719000
34719000
4543000
4543000
4543500
4543500
4544000
4544000
4544500
4544500
4545000
4545000
4545500
4545500
4546000
4546000
4546500
4546500
4547000
4547000
4547500
4547500
Attachment 1
GCS01-WGP-000-S-TRS-0002
127D5 G1, Rev. 00
Trans Adriatic Pipeline AG
Proposed Gas Compression Station
GCS01, district Central Macedonia, Greece
Alternative D
Final stage (20 billion m³ / year)
Topographical Overview
Map Source:
Google Earth
-----------------------------------------------------------
Legend
Receptor
Industry building
noise source (point)
noise source (line)
noise source (area)
Noise Level
LAeq
= 25 dB(A)
= 30 dB(A)
= 35 dB(A)
= 40 dB(A)
= 45 dB(A)
= 50 dB(A)
= 55 dB(A)
= 60 dB(A)
= 65 dB(A)
= 70 dB(A)
= 75 dB(A)
Scale (on paper size A3) 1:20000
00 100 200 400 600 800 1000m
Vent
Oil CoolerOil Cooler
Compressor Building
Parking Area
Oil Cooler
Stack Stack Stack
Unit 3
ChromatographCondensate\PTank
Scraper Receiving Station
Scraper Launching Station
Metering
Filter Separator 1-5
Transportation Gas Cooler
Start Up Gas Cooler
Transportation Gas Cooler
+17,10m
+1,50m
+1,50m
%%P 0,00m%%P 0,00m
%%P 0,00m
+1,50m
- 1,50m
- 1,50m
%%P 0,00m
%%P 0,00m
%%P 0,00m
- 1,50m
%%P 0,00m
- 1,50m
%%P 0,00m
Extinguishing Water Supply
(Small Sewage Works)
(Small Sewage Works)
Waste Water Treatment Plant
Unit 4 Unit 5Oil Cooler
Stack+17,10m
Oil Cooler
Stack+17,10m
+1,50m
+1,50m
%%P 0,00m
Unit 2Unit 1
+17,10m +17,10m
Workshop Building
+9,00m
Administration Building
+4,50m
+9,00m
Stores Building
+4,50m
+9,00m Utility Building
Main Power Generation (Diesel)
Electrical Building+4,50m
Diesel Fuel TankEmergency Power Generation (Diesel)
Second Access for Fire Brigade and Emergency Exit
5
m²
KWm²
6,3
KW
Emergency
Emergency Exit
Emergency Exit
Parking Area
+4,50m
Fuel Gas Skid
Fuel GasFuel Gas
Fuel Gas Filter
+4,50m
Power Generation (Gas)
+4,50m
%%P 0,00m
Compressor Building Compressor BuildingCompressor BuildingCompressor Building
34715500
34715500
34715600
34715600
34715700
34715700
34715800
34715800
34715900
34715900
34716000
34716000
4544900
4544900
4545000
4545000
4545100
4545100
4545200
4545200
4545300
4545300
Attachment 2
GCS01-WGP-000-S-TRS-0002127D5 G1, Rev. 00
Trans Adriatic Pipeline AG
Proposed Gas Compression Station
GCS01, district Central Macedonia, Greece
Alternative D
Station Layout
Final stage (20 billion m³ / year)
Map Source:1) Drawing file GCS01-ENT-000-Q-DQA-0009
-----------------------------------------------------------
Legend
Receptor
Industry building
noise source (point)
noise source (line)
noise source (area)
Hauptgebäude
Noise LevelLAeq
= 25 dB(A)= 30 dB(A)= 35 dB(A)= 40 dB(A)= 45 dB(A)= 50 dB(A)= 55 dB(A)= 60 dB(A)= 65 dB(A)= 70 dB(A)= 75 dB(A)
Scale (on paper size A3) 1:200000 10 20 40 60 80 100
m
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Legende Source No. Number of sourceSource Source nameGroup Group nameLi dB(A) Indoor sound pressure levelR'w dB Transmission lossLw' dB(A) Sound power level per m,m²l or S m,m² Size of source (length or area)Lw dB(A) Sound power level per unitKo dB Correction for non spherical emissions m Distance source - receptor pointAdiv dB Attenuation due to divergenceAgr dB Attenuation due to ground effectsAbar dB Attenuation due to barrierAatm dB Attenuation due to atmospheric absorptiondLrefl dB Increase of noise due to reflectionsCmet Meteorological correctionLr,i dB(A) Assessed sound pressure at receiver
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.1 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
Name 1 Krinos Ln = 26,1 dB(A)
347 Air condition unit I Administration Building 0,00 0,00 87,00 87,00 0,00 1667,93 -75,44 -0,93 -3,40 -3,88 2,54 0,00 5,90
348 Air condition unit II Administration Building 0,00 0,00 87,00 87,00 0,00 1665,19 -75,42 -0,93 -3,39 -3,87 2,54 0,00 5,92
349 Air condition unit III Administration Building 0,00 0,00 87,00 87,00 0,00 1664,73 -75,42 -0,87 -3,40 -3,87 2,54 0,00 5,97
350 Air condition unit IV Administration Building 0,00 0,00 87,00 87,00 0,00 1661,95 -75,40 -0,91 -3,39 -3,87 2,54 0,00 5,96
10 Building vent., exhaust 1 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 1788,70 -76,04 0,81 -4,09 -3,51 0,00 0,00 3,17
11 Building vent., exhaust 2 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 1784,25 -76,02 0,80 -4,11 -3,53 0,00 0,00 3,14
12 Building vent., exhaust 3 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 1794,37 -76,07 0,82 -4,09 -3,51 2,36 0,00 5,51
13 Building vent., exhaust 4 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 1789,49 -76,05 0,80 -4,11 -3,53 2,38 0,00 5,50
5 Facade N, GT air intake Compressor Building Unit 1 0,00 0,00 74,26 3,75 80,00 3,00 1778,85 -75,99 0,38 -3,65 -1,85 0,00 0,00 1,89
4 Facade N, build. vent. air intlet Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 1775,76 -75,98 1,98 -1,79 -2,53 0,00 0,00 -6,27
3 Facade N, large door Compressor Building Unit 1 94,00 30,00 59,73 15,57 71,66 3,00 1781,39 -76,01 1,60 -4,37 -7,12 0,00 0,00 -11,23
6 Facade N, package ventilation, air inlet Compressor Building Unit 1 0,00 0,00 74,02 2,50 78,00 3,00 1778,85 -75,99 3,89 -4,51 -0,95 0,00 0,00 3,44
22 Facade S, build. vent. air inlet Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 1799,78 -76,10 2,00 - -0,58 0,00 0,00 -18,87
21 Facade S, door Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 1803,43 -76,11 1,69 - -3,00 0,00 0,00 -26,59
7 Facade S, small door Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 1782,90 -76,01 1,66 -4,55 -7,03 0,00 0,00 -14,91
18 Facade W, build. vent. air inlet I Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 1779,56 -76,00 1,98 -2,74 -2,03 0,00 0,00 -6,73
19 Facade W, build. vent. air inlet II Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 1790,71 -76,05 1,99 -3,18 -2,12 0,00 0,00 -7,29
15 Facade W, door 1 Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 1776,89 -75,99 1,66 -3,43 -6,45 0,00 0,00 -13,19
16 Facade W, door 2 Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 1793,83 -76,07 1,69 -4,36 -6,67 0,00 0,00 -14,39
17 Facade W, package ventilation outlet Compressor Building Unit 1 0,00 0,00 78,00 1,00 78,00 3,00 1786,24 -76,03 3,84 -2,28 -0,62 0,00 0,00 5,91
2 Facade north Compressor Building Unit 1 94,00 48,00 42,00 282,61 66,51 3,00 1778,74 -75,99 -0,17 -2,43 -3,64 0,00 0,00 -12,71
20 Facade south Compressor Building Unit 1 94,00 48,00 42,00 304,43 66,84 3,00 1799,37 -76,09 0,00 - -1,06 0,00 0,00 -20,73
14 Facade west Compressor Building Unit 1 94,00 48,00 42,00 359,86 67,56 3,00 1784,89 -76,02 -0,06 -2,39 -3,47 0,00 0,00 -11,38
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.2 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
8 Roof Compressor Building Unit 1 94,00 45,00 45,41 352,54 70,88 0,00 1789,40 -76,05 -1,15 -3,01 -2,89 0,00 0,00 -12,22
29 air intake duct Compressor Building Unit 1 0,00 0,00 80,00 80,00 0,00 1774,54 -75,97 -0,07 -3,11 -1,92 2,52 0,00 1,45
27 oil demister Compressor Building Unit 1 0,00 0,00 80,00 80,00 0,00 1783,59 -76,02 0,12 -0,28 -7,77 2,53 0,00 -1,42
9 roof, explosion panel Compressor Building Unit 1 94,00 16,00 74,24 100,10 94,24 0,00 1789,32 -76,05 -0,76 -3,53 -4,16 0,29 0,00 10,04
40 Building vent., exhaust 1 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 1823,55 -76,21 0,83 -4,09 -3,52 0,00 0,00 3,00
41 Building vent., exhaust 2 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 1819,19 -76,19 0,81 -4,12 -3,54 0,00 0,00 2,97
42 Building vent., exhaust 3 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 1829,63 -76,24 0,83 -4,09 -3,52 0,00 0,00 2,98
43 Building vent., exhaust 4 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 1824,83 -76,22 0,82 -4,11 -3,54 0,00 0,00 2,95
35 Facade N, GT air intake Compressor Building Unit 3 0,00 0,00 74,26 3,75 80,00 3,00 1814,13 -76,17 0,38 -2,58 -1,53 0,00 0,00 3,10
34 Facade N, build. vent. air intlet Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 1810,82 -76,15 1,98 -2,44 -2,10 0,00 0,00 -6,64
33 Facade N, large door Compressor Building Unit 3 94,00 30,00 59,73 15,57 71,66 3,00 1816,84 -76,18 1,60 -4,38 -6,71 0,00 0,00 -11,01
36 Facade N, package ventilation, air inlet Compressor Building Unit 3 0,00 0,00 74,02 2,50 78,00 3,00 1814,13 -76,17 3,90 -2,70 -0,65 0,00 0,00 5,38
52 Facade S, build. vent. air inlet Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 1834,67 -76,26 2,00 - -0,59 0,00 0,00 -19,16
51 Facade S, door Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 1838,58 -76,28 1,69 - -3,48 0,00 0,00 -28,10
37 Facade S, small door Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 1818,46 -76,19 1,66 -4,43 -6,76 0,00 0,00 -14,70
48 Facade W, build. vent. air inlet I Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 1814,45 -76,17 1,98 -2,34 -2,10 0,00 0,00 -6,56
49 Facade W, build. vent. air inlet II Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 1825,37 -76,22 1,99 -2,98 -2,06 0,00 0,00 -7,19
45 Facade W, door 1 Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 1811,83 -76,15 1,66 -2,36 -6,80 0,00 0,00 -12,64
46 Facade W, door 2 Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 1828,44 -76,23 1,69 -4,16 -6,60 0,00 0,00 -14,28
47 Facade W, package ventilation outlet Compressor Building Unit 3 0,00 0,00 78,00 1,00 78,00 3,00 1821,00 -76,20 3,85 -2,20 -0,63 0,00 0,00 5,82
32 Facade north Compressor Building Unit 3 94,00 48,00 42,00 282,61 66,51 3,00 1814,02 -76,16 -0,15 -1,33 -3,66 0,00 0,00 -11,78
50 Facade south Compressor Building Unit 3 94,00 48,00 42,00 304,43 66,84 3,00 1834,23 -76,26 0,02 - -1,04 0,00 0,00 -21,83
44 Facade west Compressor Building Unit 3 94,00 48,00 42,00 359,86 67,56 3,00 1819,68 -76,19 -0,06 -2,03 -3,18 0,00 0,00 -10,91
38 Roof Compressor Building Unit 3 94,00 45,00 45,41 352,54 70,88 0,00 1824,49 -76,21 -1,14 -3,02 -2,93 0,00 0,00 -12,43
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.3 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
57 air intake duct Compressor Building Unit 3 0,00 0,00 80,00 80,00 0,00 1810,37 -76,15 -0,05 -3,01 -2,01 2,52 0,00 1,30
56 oil demister Compressor Building Unit 3 0,00 0,00 80,00 80,00 0,00 1818,36 -76,19 0,13 -0,23 -7,79 2,54 0,00 -1,53
39 roof, explosion panel Compressor Building Unit 3 94,00 16,00 74,24 100,10 94,24 0,00 1824,42 -76,21 -0,75 -3,53 -4,23 0,00 0,00 9,52
69 Building vent., exhaust 1 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 1833,30 -76,26 0,83 -4,13 -3,56 0,00 0,00 2,88
70 Building vent., exhaust 2 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 1828,95 -76,24 0,82 -4,10 -3,52 0,00 0,00 2,96
71 Building vent., exhaust 3 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 1839,94 -76,29 0,83 -4,18 -3,62 0,00 0,00 2,74
72 Building vent., exhaust 4 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 1834,74 -76,26 0,82 -4,11 -3,54 0,00 0,00 2,90
80 Facade E, build. vent. air inlet I Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 1844,56 -76,31 2,00 - -0,59 0,00 0,00 -19,08
81 Facade E, build. vent. air inlet II Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 1833,74 -76,26 1,98 - -0,56 0,00 0,00 -18,15
78 Facade E, door 1 Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 1847,16 -76,32 1,69 - -3,50 0,00 0,00 -28,97
77 Facade E, door 2 Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 1830,72 -76,24 1,66 - -3,20 0,00 0,00 -27,90
79 Facade E, package ventilation, air ou Compressor Building Unit 4 0,00 0,00 78,00 1,00 78,00 3,00 1838,06 -76,28 3,85 - -0,25 0,00 0,00 -4,72
64 Facade N, GT air intake Compressor Building Unit 4 0,00 0,00 74,26 3,75 80,00 3,00 1824,47 -76,21 0,38 -3,29 -1,64 0,00 0,00 2,23
63 Facade N, build. vent. air inlet Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 1827,61 -76,23 1,98 -3,84 -2,43 0,00 0,00 -8,45
62 Facade N, large door Compressor Building Unit 4 94,00 30,00 59,73 15,57 71,66 3,00 1821,28 -76,20 1,60 -4,48 -6,82 0,00 0,00 -11,23
65 Facade N, package ventilation, air i Compressor Building Unit 4 0,00 0,00 74,02 2,50 78,00 3,00 1824,47 -76,21 3,90 -3,67 -0,74 0,00 0,00 4,27
66 Facade N, small door Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 1819,97 -76,19 1,66 -4,46 -6,80 0,00 0,00 -14,78
75 Facade S, build. vent. air inlet Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 1844,42 -76,31 2,00 - -0,61 0,00 0,00 -19,71
74 Facade S, door Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 1840,72 -76,29 1,69 - -3,45 0,00 0,00 -29,38
76 Facade east Compressor Building Unit 4 94,00 48,00 42,00 359,86 67,56 3,00 1839,31 -76,29 -0,05 - -1,35 0,00 0,00 -18,41
61 Facade north Compressor Building Unit 4 94,00 48,00 42,00 282,61 66,51 3,00 1824,72 -76,22 -0,15 -1,29 -3,74 0,00 0,00 -11,88
73 Facade south Compressor Building Unit 4 94,00 48,00 42,00 304,43 66,84 3,00 1844,80 -76,31 0,05 - -1,00 0,00 0,00 -22,52
67 Roof Compressor Building Unit 4 94,00 45,00 45,41 352,54 70,88 0,00 1834,29 -76,26 -1,14 -3,03 -2,95 0,00 0,00 -12,50
86 air intake duct Compressor Building Unit 4 0,00 0,00 80,00 80,00 0,00 1820,11 -76,19 -0,04 -3,02 -2,01 2,51 0,00 1,24
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.4 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
85 oil demister Compressor Building Unit 4 0,00 0,00 80,00 80,00 0,00 1838,46 -76,28 0,13 - -3,69 0,00 0,00 -12,42
68 roof, explosion panel Compressor Building Unit 4 94,00 16,00 74,24 100,10 94,24 0,00 1834,23 -76,26 -0,75 -3,54 -4,24 0,00 0,00 9,46
98 Building vent., exhaust 1 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 1861,33 -76,39 0,84 -4,10 -3,54 0,00 0,00 2,81
99 Building vent., exhaust 2 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 1857,05 -76,37 0,83 -4,08 -3,52 0,00 0,00 2,86
100 Building vent., exhaust 3 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 1867,78 -76,42 0,84 -4,18 -3,63 0,00 0,00 2,61
101 Building vent., exhaust 4 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 1863,08 -76,40 0,83 -4,11 -3,56 0,00 0,00 2,76
93 Facade N, GT air intake Compressor Building Unit 5 0,00 0,00 74,26 3,75 80,00 3,00 1852,33 -76,35 0,39 0,00 -1,87 0,00 0,00 5,17
92 Facade N, build. vent. air intlet Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 1848,81 -76,33 1,98 0,00 -2,98 0,00 0,00 -5,26
91 Facade N, large door Compressor Building Unit 5 94,00 30,00 59,73 15,57 71,66 3,00 1855,21 -76,36 1,60 0,00 -7,43 0,00 0,00 -7,53
94 Facade N, package ventilation, air inlet Compressor Building Unit 5 0,00 0,00 74,02 2,50 78,00 3,00 1852,33 -76,35 3,90 0,00 -0,88 0,00 0,00 7,68
110 Facade S, build. vent. air inlet Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 1872,46 -76,44 2,00 - -0,61 0,00 0,00 -19,58
109 Facade S, door Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 1876,61 -76,46 1,70 - -3,10 0,00 0,00 -27,01
95 Facade S, small door Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 1856,92 -76,37 1,66 0,00 -7,44 0,00 0,00 -11,12
106 Facade W, build. vent. air inlet I Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 1852,27 -76,35 1,98 0,00 -2,99 0,00 0,00 -5,28
107 Facade W, build. vent. air inlet II Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 1862,98 -76,40 2,00 -2,59 -2,05 0,00 0,00 -6,97
103 Facade W, door 1 Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 1849,71 -76,33 1,66 0,00 -7,42 0,00 0,00 -11,07
104 Facade W, door 2 Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 1865,98 -76,41 1,69 -3,79 -6,62 0,00 0,00 -14,10
105 Facade W, package ventilation outlet Compressor Building Unit 5 0,00 0,00 78,00 1,00 78,00 3,00 1858,68 -76,38 3,85 -1,66 -0,69 0,00 0,00 6,12
90 Facade north Compressor Building Unit 5 94,00 48,00 42,00 282,61 66,51 3,00 1852,21 -76,35 -0,13 0,00 -3,38 0,00 0,00 -10,35
108 Facade south Compressor Building Unit 5 94,00 48,00 42,00 304,43 66,84 3,00 1872,00 -76,44 0,03 - -1,10 0,00 0,00 -20,81
102 Facade west Compressor Building Unit 5 94,00 48,00 42,00 359,86 67,56 3,00 1857,39 -76,37 -0,03 -0,76 -3,63 0,00 0,00 -10,23
96 Roof Compressor Building Unit 5 94,00 45,00 45,41 352,54 70,88 0,00 1862,53 -76,39 -1,13 -3,03 -2,98 0,00 0,00 -12,65
115 air intake duct Compressor Building Unit 5 0,00 0,00 80,00 80,00 0,00 1848,57 -76,33 -0,02 0,00 -1,84 2,55 0,00 4,35
114 oil demister Compressor Building Unit 5 0,00 0,00 80,00 80,00 0,00 1855,50 -76,36 0,14 -0,01 -7,58 2,54 0,00 -1,29
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.5 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
97 roof, explosion panel Compressor Building Unit 5 94,00 16,00 74,24 100,10 94,24 0,00 1862,45 -76,39 -0,74 -3,54 -4,29 0,00 0,00 9,28
340 Facade E Electrical Building 87,43 37,00 39,28 92,30 58,93 3,00 1750,49 -75,86 1,39 - -6,44 0,00 0,00 -33,19
341 Facade E, sec. 1 Electrical Building 87,43 37,00 39,28 127,16 60,33 3,00 1734,33 -75,77 0,89 0,00 -7,95 0,00 0,00 -19,51
342 Facade E, sec. 2 Electrical Building 87,43 37,00 39,28 8,11 48,37 3,00 1726,44 -75,74 0,97 -9,13 -6,71 0,00 0,00 -39,22
343 Facade E, sec. 3 Electrical Building 87,43 37,00 39,28 58,38 56,94 3,00 1722,36 -75,71 0,84 0,00 -7,91 0,00 0,00 -22,84
344 Facade E, sec. 4 Electrical Building 87,43 37,00 39,28 2,59 43,42 3,00 1719,39 -75,70 0,84 0,00 -7,90 0,00 0,00 -36,34
345 Facade E, sec. 5 Electrical Building 87,43 37,00 39,28 67,56 57,58 3,00 1715,88 -75,68 0,85 -3,66 -8,12 0,00 0,00 -26,04
334 Facade S, sec. 1 Electrical Building 87,43 37,00 39,28 72,39 57,88 3,00 1735,05 -75,78 1,46 - -6,44 0,00 0,00 -35,09
336 Facade S, sec. 2 Electrical Building 87,43 37,00 39,28 5,65 46,80 3,00 1738,53 -75,80 1,46 - -6,50 0,00 0,00 -46,62
337 Facade S, sec. 3 Electrical Building 87,43 37,00 39,28 48,15 56,11 3,00 1740,62 -75,81 1,45 - -6,50 0,00 0,00 -37,39
338 Facade S, sec. 4 Electrical Building 87,43 37,00 39,28 6,42 47,36 3,00 1743,85 -75,82 1,46 - -6,96 0,00 0,00 -43,18
339 Facade S, sec. 5 Electrical Building 87,43 37,00 39,28 131,91 60,48 3,00 1751,79 -75,86 1,47 - -6,53 0,00 0,00 -33,19
346 Facade W Electrical Building 87,43 37,00 39,28 97,41 59,17 3,00 1721,61 -75,71 1,11 -3,94 -8,06 0,00 0,00 -24,43
335 Roof Electrical Building 87,43 37,00 39,28 1181,57 70,01 0,00 1735,21 -75,78 0,82 -4,65 -7,62 0,00 0,00 -17,23
117 Filter I Filter 0,00 0,00 69,83 5,21 77,00 0,00 1940,60 -76,75 0,95 -2,92 -5,09 0,00 0,00 -6,81
118 Filter II Filter 0,00 0,00 69,82 5,22 77,00 0,00 1936,67 -76,73 0,95 -2,24 -7,45 0,00 0,00 -8,47
119 Filter IV Filter 0,00 0,00 69,80 5,25 77,00 0,00 1928,90 -76,70 0,95 -4,04 -5,88 0,00 0,00 -8,67
120 Filter V Filter 0,00 0,00 69,80 5,25 77,00 0,00 1925,00 -76,68 0,92 -4,03 -5,87 0,00 0,00 -8,65
122 Explosion relief panel Fuel Gas Skid I 87,00 16,00 66,62 30,00 81,39 0,00 1870,68 -76,43 0,37 -4,19 -4,96 0,00 0,00 -3,82
125 Fuel Gas Skid, facade E Fuel Gas Skid I 87,00 37,00 45,32 126,06 66,33 3,00 1872,76 -76,44 0,74 -5,72 -5,41 0,00 0,00 -17,51
126 Fuel Gas Skid, facade E, door Fuel Gas Skid I 87,00 30,00 57,56 4,84 64,41 3,00 1867,36 -76,42 1,66 - -5,45 0,00 0,00 -28,73
123 Fuel Gas Skid, facade S Fuel Gas Skid I 87,00 37,00 45,32 61,38 63,20 3,00 1877,83 -76,47 0,70 -5,83 -5,40 0,00 0,00 -20,79
124 Fuel Gas Skid, facade S, door Fuel Gas Skid I 87,00 37,00 45,32 7,04 53,80 3,00 1877,88 -76,47 0,92 - -4,19 0,00 0,00 -38,07
128 Fuel Gas Skid, facade W Fuel Gas Skid I 87,00 37,00 45,32 130,90 66,49 3,00 1869,12 -76,42 0,76 -4,09 -5,35 0,00 0,00 -15,63
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.6 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
121 Fuel Gas Skid, roof Fuel Gas Skid I 87,00 37,00 45,32 93,97 65,05 0,00 1870,72 -76,43 0,76 -4,58 -5,21 0,00 0,00 -20,41
127 Ventilation, intake Fuel Gas Skid I 0,00 0,00 68,00 68,00 6,01 1870,21 -76,43 -4,74 -8,41 -4,36 0,00 0,00 -19,94
129 Ventilation, outlet Fuel Gas Skid I 0,00 0,00 68,00 68,00 6,01 1873,90 -76,45 -4,74 0,00 -4,37 0,00 0,00 -11,55
131 Explosion relief panel Fuel Gas Skid II 87,00 16,00 66,62 30,00 81,39 0,00 1856,48 -76,37 0,37 -4,19 -4,93 0,00 0,00 -3,73
132 Fuel Gas Skid, facade E Fuel Gas Skid II 87,00 37,00 45,32 126,06 66,33 3,00 1857,71 -76,37 0,73 -5,68 -5,29 0,00 0,00 -17,27
133 Fuel Gas Skid, facade E, door Fuel Gas Skid II 87,00 37,00 45,32 4,84 52,17 3,00 1862,36 -76,39 0,93 - -4,26 0,00 0,00 -38,02
135 Fuel Gas Skid, facade N Fuel Gas Skid II 87,00 37,00 45,32 63,58 63,35 3,00 1849,45 -76,33 0,78 -4,08 -5,32 0,00 0,00 -18,60
136 Fuel Gas Skid, facade N, door Fuel Gas Skid II 87,00 37,00 45,32 4,84 52,17 3,00 1849,42 -76,33 0,91 -4,57 -5,18 0,00 0,00 -30,00
137 Fuel Gas Skid, facade W Fuel Gas Skid II 87,00 37,00 45,32 130,90 66,49 3,00 1854,91 -76,36 0,75 -4,08 -5,32 0,00 0,00 -15,52
130 Fuel Gas Skid, roof Fuel Gas Skid II 87,00 37,00 45,32 93,97 65,05 0,00 1856,52 -76,37 0,75 -4,58 -5,17 0,00 0,00 -20,31
134 Ventilation, intake Fuel Gas Skid II 0,00 0,00 68,00 68,00 6,01 1853,41 -76,35 -4,74 -6,27 -4,32 0,00 0,00 -17,67
138 Ventilation, outlet Fuel Gas Skid II 0,00 0,00 68,00 68,00 6,01 1859,68 -76,38 -4,74 0,00 -4,34 0,00 0,00 -11,45
296 Meter Run I Metering 0,00 0,00 72,70 39,44 88,66 0,00 1900,63 -76,57 2,13 -2,06 -9,19 0,00 0,00 2,99
297 Meter Run II Metering 0,00 0,00 72,70 39,45 88,66 0,00 1899,36 -76,56 2,13 -4,32 -9,59 0,00 0,00 0,31
298 Meter Run IV Metering 0,00 0,00 72,70 39,50 88,66 0,00 1896,86 -76,55 2,11 -4,35 -9,57 0,00 0,00 0,30
299 Meter Run V Metering 0,00 0,00 72,70 39,48 88,66 0,00 1895,60 -76,55 2,10 -4,37 -9,55 0,00 0,00 0,30
143 Header discharge side Piping 0,00 0,00 80,00 136,93 101,37 0,00 1836,96 -76,27 1,39 -6,12 -6,66 0,37 0,00 14,08
233 Header discharge side Piping 0,00 0,00 80,00 89,78 99,53 0,00 1881,20 -76,48 1,39 -8,46 -6,35 0,93 0,00 10,57
234 Header suction side Piping 0,00 0,00 78,00 93,78 97,72 0,00 1884,14 -76,49 1,40 -6,88 -6,76 0,39 0,00 9,38
144 Header suction side Piping 0,00 0,00 78,00 108,68 98,36 0,00 1838,72 -76,28 1,39 -7,62 -6,51 0,35 0,00 9,70
300 Facade E Power Generation Gas I 97,00 37,00 58,49 36,27 74,09 3,00 1763,72 -75,92 0,41 - -2,74 0,00 0,00 -12,24
302 Facade N Power Generation Gas I 97,00 37,00 58,49 58,24 76,15 3,00 1757,33 -75,89 0,39 -2,66 -3,70 0,02 0,00 -2,69
305 Facade S Power Generation Gas I 97,00 37,00 58,49 53,44 75,77 3,00 1764,74 -75,93 0,39 - -2,76 0,00 0,00 -11,01
306 Facade S, door Power Generation Gas I 97,00 30,00 64,01 4,84 70,86 3,00 1764,08 -75,92 1,03 - -2,11 0,00 0,00 -16,91
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.7 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
303 Facade W Power Generation Gas I 97,00 37,00 58,49 36,05 74,06 3,00 1758,26 -75,89 0,37 -4,37 -3,77 0,00 0,00 -6,60
308 Power Generation Gas I, Exhaust Stack Power Generation Gas I 0,00 0,00 90,00 90,00 0,00 1764,11 -75,92 0,10 -2,82 -2,69 0,00 0,00 8,67
301 Roof Power Generation Gas I 97,00 37,00 58,49 104,04 78,67 0,00 1761,00 -75,91 0,21 -4,43 -3,73 0,00 0,00 -5,19
304 Room ventilation, intake Power Generation Gas I 0,00 0,00 76,00 76,00 6,01 1759,17 -75,90 -4,75 0,00 -4,10 0,00 0,00 -2,74
307 Room ventilation, outlet Power Generation Gas I 0,00 0,00 76,00 76,00 6,01 1765,59 -75,93 -4,75 - -4,12 0,00 0,00 -13,36
313 Facade E Power Generation Gas II 97,00 37,00 58,49 36,40 74,11 3,00 1745,65 -75,83 0,37 -8,66 -2,88 0,00 0,00 -9,90
314 Facade N Power Generation Gas II 97,00 37,00 58,49 53,35 75,77 3,00 1739,15 -75,80 0,37 -4,35 -3,74 0,00 0,00 -4,75
315 Facade N, door Power Generation Gas II 97,00 30,00 64,01 4,84 70,86 3,00 1739,81 -75,80 1,01 -4,45 -4,72 0,00 0,00 -10,10
312 Facade S Power Generation Gas II 97,00 37,00 63,49 58,05 81,13 3,00 1746,56 -75,84 0,38 - -2,67 3,39 0,00 -2,12
309 Facade W Power Generation Gas II 97,00 37,00 58,49 36,20 74,08 3,00 1740,13 -75,80 0,37 -4,36 -3,74 0,00 0,00 -6,45
317 Power Generation Gas II, Exhaust Stack Power Generation Gas II 0,00 0,00 90,00 90,00 0,00 1746,47 -75,84 -0,05 -2,74 -2,63 0,00 0,00 8,75
311 Roof Power Generation Gas II 97,00 37,00 58,49 104,19 78,67 0,00 1742,91 -75,82 0,11 -4,40 -3,69 0,00 0,00 -5,12
310 Room ventilation, intake Power Generation Gas II 0,00 0,00 76,00 76,00 6,01 1741,03 -75,81 -4,75 0,00 -4,06 0,00 0,00 -2,61
316 Room ventilation, outlet Power Generation Gas II 0,00 0,00 76,00 76,00 6,01 1738,28 -75,79 -4,75 0,00 -4,05 0,00 0,00 -2,59
159 Distrib. pipe 1 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 1867,49 -76,42 2,24 -4,46 - 0,00 0,00 -16,41
146 Distrib. pipe 1 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 1847,68 -76,32 2,16 -4,67 - 0,00 0,00 -13,21
160 Distrib. pipe 2 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 1867,90 -76,42 2,24 -4,51 - 0,00 0,00 -16,53
148 Distrib. pipe 2 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 1848,12 -76,33 2,16 -4,67 - 0,00 0,00 -13,21
161 Distrib. pipe 3 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 1868,32 -76,42 2,24 -4,55 - 0,00 0,00 -16,62
149 Distrib. pipe 3 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 1848,52 -76,33 2,16 -4,67 - 0,00 0,00 -13,21
162 Distrib. pipe 4 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 1868,82 -76,42 2,24 -4,58 - 0,00 0,00 -16,72
150 Distrib. pipe 4 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 1849,06 -76,33 2,16 -4,67 - 0,00 0,00 -13,20
163 Distrib. pipe 5 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 1869,23 -76,43 2,24 -4,60 - 0,00 0,00 -16,78
151 Distrib. pipe 5 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 1849,50 -76,33 2,16 -4,66 - 0,00 0,00 -13,19
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.8 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
164 Distrib. pipe 6 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 1869,65 -76,43 2,24 -4,62 - 0,00 0,00 -16,83
152 Distrib. pipe 6 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 1849,90 -76,34 2,16 -4,66 - 0,00 0,00 -13,18
165 Distrib. pipe 7 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 1870,18 -76,43 2,24 -4,63 - 0,00 0,00 -16,88
153 Distrib. pipe 7 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 1850,40 -76,34 2,16 -4,65 - 0,00 0,00 -13,14
166 Distrib. pipe 8 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 1870,60 -76,43 2,24 -4,64 - 0,00 0,00 -16,91
154 Distrib. pipe 8 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 1850,84 -76,34 2,16 -4,64 - 0,00 0,00 -13,11
167 Distrib. pipe 9 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 1871,02 -76,43 2,24 -4,65 - 0,00 0,00 -16,94
155 Distrib. pipe 9 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 1851,25 -76,34 2,16 -4,62 - 0,00 0,00 -13,07
168 Distrib. pipe 10 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 1871,53 -76,44 2,24 -4,65 - 0,00 0,00 -16,96
156 Distrib. pipe 10 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 1851,77 -76,34 2,16 -4,60 - 0,00 0,00 -13,01
169 Distrib. pipe 11 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 1871,95 -76,44 2,24 -4,66 - 0,00 0,00 -16,98
157 Distrib. pipe 11 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 1852,21 -76,35 2,16 -4,58 - 0,00 0,00 -12,95
170 Distrib. pipe 12 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 1872,37 -76,44 2,24 -4,66 - 0,00 0,00 -16,98
158 Distrib. pipe 12 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 1852,61 -76,35 2,16 -4,54 - 0,00 0,00 -12,86
295 Header discharge side, Start Up Cooler Start Up Cooler 0,00 0,00 80,00 94,83 99,77 0,00 1883,86 -76,49 1,40 -8,77 -6,23 0,44 0,00 10,11
229 Header discharge side, Start Up Cooler Start Up Cooler 0,00 0,00 80,00 164,54 102,16 0,00 1840,20 -76,29 1,40 -5,99 -6,63 0,15 0,00 14,81
140 Start Up Cooler Start Up Cooler 0,00 0,00 66,17 191,91 89,00 0,00 1860,77 -76,39 1,06 -3,85 -5,81 0,00 0,00 4,02
142 Start Up Cooler, gas flow noise Start Up Cooler 0,00 0,00 70,16 192,32 93,00 0,00 1860,79 -76,39 1,06 -3,85 -5,81 0,00 0,00 8,02
147 Distrib. pipe 1 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1871,68 -76,44 2,26 -4,66 - 0,00 0,00 -17,70
293 Distrib. pipe 1 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1892,48 -76,53 2,26 -7,98 - 0,00 0,00 -19,39
200 Distrib. pipe 2 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1872,10 -76,44 2,26 -4,66 - 0,00 0,00 -17,70
294 Distrib. pipe 2 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1892,93 -76,53 2,26 -7,97 - 0,00 0,00 -19,39
201 Distrib. pipe 3 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1872,52 -76,44 2,26 -4,66 - 0,00 0,00 -17,69
265 Distrib. pipe 3 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1893,38 -76,54 2,26 -7,97 - 0,00 0,00 -19,38
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.9 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
202 Distrib. pipe 4 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1873,06 -76,44 2,26 -4,65 - 0,00 0,00 -17,67
266 Distrib. pipe 4 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1893,93 -76,54 2,26 -7,81 - 0,00 0,00 -19,00
267 Distrib. pipe 5 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1894,38 -76,54 2,26 -7,89 - 0,00 0,00 -19,20
203 Distrib. pipe 5 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1873,48 -76,45 2,26 -4,64 - 0,00 0,00 -17,65
268 Distrib. pipe 6 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1894,82 -76,54 2,26 -7,90 - 0,00 0,00 -19,24
204 Distrib. pipe 6 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1873,90 -76,45 2,26 -4,63 - 0,00 0,00 -17,62
269 Distrib. pipe 7 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1895,33 -76,55 2,26 -7,92 - 0,00 0,00 -19,29
205 Distrib. pipe 7 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1874,40 -76,45 2,26 -4,62 - 0,00 0,00 -17,58
206 Distrib. pipe 8 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1874,82 -76,45 2,26 -4,60 - 0,00 0,00 -17,54
270 Distrib. pipe 8 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1895,78 -76,55 2,26 -7,92 - 0,00 0,00 -19,32
207 Distrib. pipe 9 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1875,24 -76,45 2,26 -4,58 - 0,00 0,00 -17,48
271 Distrib. pipe 9 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1896,22 -76,55 2,26 -7,93 - 0,00 0,00 -19,35
272 Distrib. pipe 10 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1896,78 -76,55 2,26 -7,93 - 0,00 0,00 -19,38
208 Distrib. pipe 10 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1875,78 -76,46 2,26 -4,54 - 0,00 0,00 -17,39
209 Distrib. pipe 11 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1876,21 -76,46 2,26 -4,50 - 0,00 0,00 -17,30
273 Distrib. pipe 11 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1897,22 -76,55 2,26 -7,93 - 0,00 0,00 -19,40
210 Distrib. pipe 12 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1876,63 -76,46 2,26 -4,44 - 0,00 0,00 -17,20
274 Distrib. pipe 12 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1897,67 -76,56 2,26 -7,91 - 0,00 0,00 -19,41
211 Distrib. pipe 13 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1877,17 -76,46 2,26 -4,44 - 0,00 0,00 -17,06
275 Distrib. pipe 13 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1898,23 -76,56 2,26 -7,63 - 0,00 0,00 -19,29
212 Distrib. pipe 14 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1877,60 -76,46 2,26 -6,90 - 0,00 0,00 -17,50
276 Distrib. pipe 14 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1898,67 -76,56 2,26 -7,42 - 0,00 0,00 -19,20
213 Distrib. pipe 15 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1878,03 -76,47 2,26 -6,19 - 0,00 0,00 -17,22
277 Distrib. pipe 15 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1899,12 -76,56 2,26 -7,22 - 0,00 0,00 -19,12
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.10 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
278 Distrib. pipe 16 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1899,68 -76,57 2,26 -6,99 - 0,00 0,00 -19,03
214 Distrib. pipe 16 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1878,57 -76,47 2,26 -3,97 - 0,00 0,00 -16,79
215 Distrib. pipe 17 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1879,00 -76,47 2,26 -5,88 - 0,00 0,00 -18,30
279 Distrib. pipe 17 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1900,13 -76,57 2,26 -6,82 - 0,00 0,00 -18,96
216 Distrib. pipe 18 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1879,42 -76,47 2,26 -6,11 - 0,00 0,00 -18,43
280 Distrib. pipe 18 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1900,58 -76,57 2,26 -6,67 - 0,00 0,00 -18,90
217 Distrib. pipe 19 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1879,93 -76,47 2,26 -5,29 - 0,00 0,00 -17,20
281 Distrib. pipe 19 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1901,10 -76,57 2,26 -6,49 - 0,00 0,00 -18,82
282 Distrib. pipe 20 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1901,55 -76,57 2,26 -6,35 - 0,00 0,00 -18,77
218 Distrib. pipe 20 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1880,36 -76,48 2,26 -5,59 - 0,00 0,00 -17,48
283 Distrib. pipe 21 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1901,99 -76,58 2,26 -6,22 - 0,00 0,00 -18,71
219 Distrib. pipe 21 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1880,78 -76,48 2,26 -5,76 - 0,00 0,00 -17,70
220 Distrib. pipe 22 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1881,33 -76,48 2,26 -5,89 - 0,00 0,00 -17,91
284 Distrib. pipe 22 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1902,56 -76,58 2,26 -6,07 - 0,00 0,00 -18,64
285 Distrib. pipe 23 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1903,01 -76,58 2,26 -9,42 - 0,00 0,00 -19,54
221 Distrib. pipe 23 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1881,76 -76,48 2,26 -5,95 - 0,00 0,00 -18,03
222 Distrib. pipe 24 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1882,19 -76,49 2,26 -5,99 - 0,00 0,00 -18,12
286 Distrib. pipe 24 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1903,46 -76,58 2,26 - - 0,00 0,00 -19,77
287 Distrib. pipe 25 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1903,98 -76,59 2,26 -4,68 - 0,00 0,00 -18,04
223 Distrib. pipe 25 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1882,69 -76,49 2,26 -6,03 - 0,00 0,00 -18,21
224 Distrib. pipe 26 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1883,12 -76,49 2,26 -6,05 - 0,00 0,00 -18,26
288 Distrib. pipe 26 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1904,43 -76,59 2,26 -4,68 - 0,00 0,00 -18,06
289 Distrib. pipe 27 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1904,88 -76,59 2,26 -4,69 - 0,00 0,00 -18,08
225 Distrib. pipe 27 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1883,55 -76,49 2,26 -6,06 - 0,00 0,00 -18,30
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.11 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
290 Distrib. pipe 28 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1905,45 -76,59 2,27 -4,69 - 0,00 0,00 -18,10
226 Distrib. pipe 28 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1884,10 -76,49 2,26 -6,07 - 0,00 0,00 -18,33
227 Distrib. pipe 29 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1884,53 -76,50 2,26 -6,07 - 0,00 0,00 -18,35
291 Distrib. pipe 29 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1905,90 -76,59 2,27 -4,69 - 0,00 0,00 -18,11
292 Distrib. pipe 30 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1906,35 -76,60 2,27 -4,69 - 0,00 0,00 -18,12
228 Distrib. pipe 30 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 1884,96 -76,50 2,26 -6,07 - 0,00 0,00 -18,36
139 Gas Cooler 1/2 Transportation Gas Cooler 0,00 0,00 66,05 495,71 93,00 0,00 1870,34 -76,43 1,07 -3,08 -5,79 0,00 0,00 8,76
145 Gas Cooler 1/2, distrib. pipe 1 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1855,51 -76,36 2,22 -4,57 - 0,00 0,00 -14,35
171 Gas Cooler 1/2, distrib. pipe 2 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1855,93 -76,36 2,22 -4,54 - 0,00 0,00 -14,27
172 Gas Cooler 1/2, distrib. pipe 3 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1856,36 -76,37 2,22 -4,49 - 0,00 0,00 -14,17
173 Gas Cooler 1/2, distrib. pipe 4 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1856,88 -76,37 2,22 -4,41 - 0,00 0,00 -14,02
174 Gas Cooler 1/2, distrib. pipe 5 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1857,31 -76,37 2,22 -9,34 - 0,00 0,00 -15,24
175 Gas Cooler 1/2, distrib. pipe 6 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1857,73 -76,37 2,22 -8,47 - 0,00 0,00 -14,81
176 Gas Cooler 1/2, distrib. pipe 7 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1858,25 -76,37 2,22 -3,88 - 0,00 0,00 -13,48
177 Gas Cooler 1/2, distrib. pipe 8 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1858,67 -76,38 2,22 -7,70 - 0,00 0,00 -15,82
178 Gas Cooler 1/2, distrib. pipe 9 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1859,10 -76,38 2,22 -8,06 - 0,00 0,00 -16,10
179 Gas Cooler 1/2, distrib. pipe 10 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1859,65 -76,38 2,22 -7,48 - 0,00 0,00 -15,40
180 Gas Cooler 1/2, distrib. pipe 11 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1860,07 -76,38 2,22 -7,36 - 0,00 0,00 -15,12
181 Gas Cooler 1/2, distrib. pipe 12 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1860,51 -76,38 2,22 -7,61 - 0,00 0,00 -15,42
182 Gas Cooler 1/2, distrib. pipe 13 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1861,01 -76,39 2,22 -7,78 - 0,00 0,00 -15,68
183 Gas Cooler 1/2, distrib. pipe 14 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1861,44 -76,39 2,22 -7,87 - 0,00 0,00 -15,83
184 Gas Cooler 1/2, distrib. pipe 15 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1861,87 -76,39 2,22 -7,92 - 0,00 0,00 -15,94
185 Gas Cooler 1/2, distrib. pipe 16 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1862,40 -76,39 2,22 -7,97 - 0,00 0,00 -16,04
186 Gas Cooler 1/2, distrib. pipe 17 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1862,83 -76,40 2,22 -7,99 - 0,00 0,00 -16,10
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.12 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
187 Gas Cooler 1/2, distrib. pipe 18 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1863,27 -76,40 2,22 -8,01 - 0,00 0,00 -16,14
188 Gas Cooler 1/2, distrib. pipe 19 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1863,83 -76,40 2,22 -8,02 - 0,00 0,00 -16,18
189 Gas Cooler 1/2, distrib. pipe 20 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1864,26 -76,40 2,22 -8,02 - 0,00 0,00 -16,20
190 Gas Cooler 1/2, distrib. pipe 21 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1864,70 -76,40 2,22 -8,02 - 0,00 0,00 -16,20
191 Gas Cooler 1/2, distrib. pipe 22 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1865,21 -76,41 2,22 -8,02 - 0,00 0,00 -16,21
192 Gas Cooler 1/2, distrib. pipe 23 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1865,64 -76,41 2,22 -7,99 - 0,00 0,00 -16,13
193 Gas Cooler 1/2, distrib. pipe 24 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1866,08 -76,41 2,22 -7,98 - 0,00 0,00 -16,13
194 Gas Cooler 1/2, distrib. pipe 25 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1866,62 -76,41 2,22 -7,97 - 0,00 0,00 -16,11
195 Gas Cooler 1/2, distrib. pipe 26 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1867,05 -76,42 2,22 -7,95 - 0,00 0,00 -16,09
196 Gas Cooler 1/2, distrib. pipe 27 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1867,49 -76,42 2,22 -7,93 - 0,00 0,00 -16,05
197 Gas Cooler 1/2, distrib. pipe 28 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1868,01 -76,42 2,22 -9,21 - 0,00 0,00 -16,49
198 Gas Cooler 1/2, distrib. pipe 29 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1868,44 -76,42 2,22 - - 0,00 0,00 -17,22
199 Gas Cooler 1/2, distrib. pipe 30 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1868,88 -76,42 2,22 - - 0,00 0,00 -17,55
141 Gas Cooler 1/2, gas flow noise Transportation Gas Cooler 0,00 0,00 66,05 495,71 93,00 0,00 1870,34 -76,43 1,07 -3,08 -5,79 0,00 0,00 8,76
231 Gas Cooler 3/4 Transportation Gas Cooler 0,00 0,00 66,04 496,15 93,00 0,00 1891,56 -76,53 1,08 -4,41 -6,12 0,00 0,00 7,03
235 Gas Cooler 3/4, distrib. pipe 1 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1876,51 -76,46 2,22 - - 0,00 0,00 -17,96
236 Gas Cooler 3/4, distrib. pipe 2 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1876,95 -76,46 2,22 - - 0,00 0,00 -17,98
237 Gas Cooler 3/4, distrib. pipe 3 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1877,40 -76,46 2,22 - - 0,00 0,00 -17,87
238 Gas Cooler 3/4, distrib. pipe 4 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1877,94 -76,47 2,22 - - 0,00 0,00 -17,60
239 Gas Cooler 3/4, distrib. pipe 5 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1878,38 -76,47 2,22 - - 0,00 0,00 -17,40
240 Gas Cooler 3/4, distrib. pipe 6 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1878,83 -76,47 2,22 -9,86 - 0,00 0,00 -17,22
241 Gas Cooler 3/4, distrib. pipe 7 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1879,36 -76,47 2,22 -9,42 - 0,00 0,00 -17,01
242 Gas Cooler 3/4, distrib. pipe 8 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1879,81 -76,47 2,22 -9,08 - 0,00 0,00 -16,84
243 Gas Cooler 3/4, distrib. pipe 9 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1880,26 -76,48 2,22 -8,77 - 0,00 0,00 -16,69
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.13 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
244 Gas Cooler 3/4, distrib. pipe 10 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1880,82 -76,48 2,22 -8,41 - 0,00 0,00 -16,51
245 Gas Cooler 3/4, distrib. pipe 11 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1881,27 -76,48 2,22 -8,14 - 0,00 0,00 -16,37
246 Gas Cooler 3/4, distrib. pipe 12 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1881,72 -76,48 2,22 -7,89 - 0,00 0,00 -16,22
247 Gas Cooler 3/4, distrib. pipe 13 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1882,25 -76,49 2,22 -7,59 - 0,00 0,00 -16,01
248 Gas Cooler 3/4, distrib. pipe 14 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1882,69 -76,49 2,22 - - 0,00 0,00 -18,16
249 Gas Cooler 3/4, distrib. pipe 15 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1883,14 -76,49 2,22 - - 0,00 0,00 -17,77
250 Gas Cooler 3/4, distrib. pipe 16 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1883,70 -76,49 2,22 -4,69 - 0,00 0,00 -14,94
251 Gas Cooler 3/4, distrib. pipe 17 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1884,15 -76,49 2,22 -4,69 - 0,00 0,00 -14,96
252 Gas Cooler 3/4, distrib. pipe 18 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1884,60 -76,50 2,22 -4,70 - 0,00 0,00 -14,98
253 Gas Cooler 3/4, distrib. pipe 19 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1885,19 -76,50 2,22 -4,70 - 0,00 0,00 -14,99
254 Gas Cooler 3/4, distrib. pipe 20 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1885,63 -76,50 2,22 -4,70 - 0,00 0,00 -15,00
255 Gas Cooler 3/4, distrib. pipe 21 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1886,09 -76,50 2,23 -4,70 - 0,00 0,00 -15,01
256 Gas Cooler 3/4, distrib. pipe 22 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1886,63 -76,51 2,23 -4,70 - 0,00 0,00 -15,02
257 Gas Cooler 3/4, distrib. pipe 23 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1887,07 -76,51 2,23 -4,70 - 0,00 0,00 -15,03
258 Gas Cooler 3/4, distrib. pipe 24 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1887,53 -76,51 2,23 -4,70 - 0,00 0,00 -15,03
259 Gas Cooler 3/4, distrib. pipe 25 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1888,09 -76,51 2,23 -4,70 - 0,00 0,00 -15,04
260 Gas Cooler 3/4, distrib. pipe 26 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1888,54 -76,51 2,23 -4,70 - 0,00 0,00 -15,04
261 Gas Cooler 3/4, distrib. pipe 27 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1889,00 -76,52 2,23 -4,70 - 0,00 0,00 -15,04
262 Gas Cooler 3/4, distrib. pipe 28 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1889,54 -76,52 2,23 -4,70 - 0,00 0,00 -15,03
263 Gas Cooler 3/4, distrib. pipe 29 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1889,99 -76,52 2,23 -4,70 - 0,00 0,00 -15,03
264 Gas Cooler 3/4, distrib. pipe 30 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 1890,45 -76,52 2,23 -4,70 - 0,00 0,00 -15,02
232 Gas Cooler 3/4, gas flow noise Transportation Gas Cooler 0,00 0,00 66,04 496,10 93,00 0,00 1891,56 -76,53 1,08 -4,41 -6,12 0,00 0,00 7,03
230 Header Discharge side Transportation Gas Cooler 0,00 0,00 78,00 90,45 97,56 0,00 1847,25 -76,32 1,43 -4,60 -6,59 0,00 0,00 11,48
28 Control valve (enclosed) Unit 1 0,00 0,00 87,00 87,00 3,01 1804,55 -76,12 -4,75 - -7,33 2,23 0,00 -15,55
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.14 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
23 Exhaust Stack Opening Unit 1 0,00 0,00 84,97 2,01 88,00 0,00 1784,09 -76,02 1,22 -2,87 -2,20 0,00 0,00 8,12
24 Exhaust duct outsde compressor Unit 1 0,00 0,00 76,40 12,10 87,23 0,00 1785,78 -76,03 2,92 -3,43 -2,65 0,85 0,00 8,89
1 Oil Cooler Unit 1 0,00 0,00 78,11 24,50 92,00 0,00 1776,73 -75,98 1,07 -3,77 -4,28 0,00 0,00 9,03
25 Piping suction side Unit 1 0,00 0,00 78,00 34,38 93,36 0,00 1812,02 -76,16 1,37 - -4,52 0,48 0,00 -2,89
26 Piping, discharge side Unit 1 0,00 0,00 80,00 30,25 94,81 0,00 1815,48 -76,17 1,37 - -4,85 0,33 0,00 -5,36
58 Control valve (eingehaust) Unit 3 0,00 0,00 87,00 87,00 3,01 1839,79 -76,29 -4,75 - -7,47 0,00 0,00 -18,20
31 Exhaust Stack Opening Unit 3 0,00 0,00 84,97 2,01 88,00 0,00 1819,09 -76,19 1,23 -2,87 -2,22 0,00 0,00 7,95
53 Exhaust duct outsde compressor Unit 3 0,00 0,00 79,40 6,06 87,23 0,00 1820,91 -76,20 2,93 -3,31 -2,60 1,59 0,00 9,63
30 Oil Cooler Unit 3 0,00 0,00 78,11 24,50 92,00 0,00 1811,93 -76,15 1,07 -3,67 -4,33 0,07 0,00 8,98
54 Piping suction side Unit 3 0,00 0,00 78,00 34,38 93,36 0,00 1847,05 -76,32 1,38 -4,15 -6,78 0,00 0,00 7,49
55 Piping, discharge side Unit 3 0,00 0,00 80,00 30,25 94,81 0,00 1850,82 -76,34 1,37 - -4,81 0,00 0,00 -5,68
87 Control valve (eingehaust) Unit 4 0,00 0,00 87,00 87,00 3,01 1849,25 -76,33 -4,75 - -7,51 0,00 0,00 -17,98
60 Exhaust Stack Opening Unit 4 0,00 0,00 84,97 2,01 88,00 0,00 1845,24 -76,31 1,24 -2,87 -2,23 0,00 0,00 7,83
82 Exhaust duct outsde compressor Unit 4 0,00 0,00 79,58 5,82 87,23 0,00 1843,30 -76,30 2,93 - -0,30 0,00 0,00 0,60
59 Oil Cooler Unit 4 0,00 0,00 78,11 24,50 92,00 0,00 1837,75 -76,28 1,07 -4,17 -4,60 0,00 0,00 8,03
83 Piping suction side Unit 4 0,00 0,00 78,00 34,38 93,36 0,00 1856,48 -76,37 1,38 - -4,96 0,20 0,00 -5,48
84 Piping, discharge side Unit 4 0,00 0,00 80,00 30,25 94,81 0,00 1860,32 -76,38 1,38 - -4,94 0,00 0,00 -5,56
116 Control valve (eingehaust) Unit 5 0,00 0,00 87,00 87,00 3,01 1877,35 -76,46 -4,75 - -7,63 0,00 0,00 -18,69
89 Exhaust Stack Opening Unit 5 0,00 0,00 84,97 2,01 88,00 0,00 1856,42 -76,37 1,25 -2,87 -2,23 0,00 0,00 7,77
111 Exhaust duct outsde compressor Unit 5 0,00 0,00 79,44 6,01 87,23 0,00 1858,41 -76,37 2,93 -2,98 -2,62 0,00 0,00 8,19
88 Oil Cooler Unit 5 0,00 0,00 78,11 24,50 92,00 0,00 1849,42 -76,33 1,08 -2,93 -4,43 0,29 0,00 9,67
112 Piping suction side Unit 5 0,00 0,00 78,00 34,38 93,36 0,00 1884,47 -76,50 1,38 - -5,31 0,00 0,00 1,57
113 Piping, discharge side Unit 5 0,00 0,00 80,00 30,25 94,81 0,00 1888,53 -76,51 1,38 - -4,85 0,00 0,00 -5,38
330 Air compressor I, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 1708,57 -75,64 -4,75 - -3,99 0,00 0,00 -27,10
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.15 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
331 Air compressor II, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 1709,50 -75,65 -4,75 - -3,99 0,00 0,00 -28,25
332 Air compressor III, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 1710,43 -75,65 -4,75 - -3,99 0,00 0,00 -28,90
320 Air compressor room, ventilation Utility Building 0,00 0,00 68,00 68,00 3,01 1701,35 -75,61 -4,68 -0,09 -3,97 0,00 0,00 -13,34
354 Air condition unit I Utility Building 0,00 0,00 87,00 87,00 0,00 1699,12 -75,60 -0,78 -3,48 -3,91 2,54 0,00 5,77
353 Air condition unit II Utility Building 0,00 0,00 87,00 87,00 0,00 1698,12 -75,59 -0,80 -3,47 -3,91 2,54 0,00 5,77
333 Boiler room, ventilation intake Utility Building 0,00 0,00 72,00 72,00 6,01 1727,54 -75,74 -4,75 - -4,03 0,00 0,00 -25,06
326 Boiler room, ventilation outlet Utility Building 0,00 0,00 72,00 72,00 6,01 1698,09 -75,59 -4,73 0,00 -3,96 0,00 0,00 -6,28
321 Boiler, stack opening I Utility Building 0,00 0,00 78,00 78,00 3,01 1724,01 -75,72 -4,68 -0,09 -4,02 0,00 0,00 -3,50
323 Boiler, stack opening III Utility Building 0,00 0,00 78,00 78,00 3,01 1718,76 -75,70 -4,68 -0,09 -4,01 0,00 0,00 -3,47
322 Boiler, stack opening Ii Utility Building 0,00 0,00 78,00 78,00 3,01 1721,38 -75,71 -4,68 -0,09 -4,02 0,00 0,00 -3,49
318 Facade E Utility Building 87,43 37,00 37,28 117,45 57,98 3,00 1722,77 -75,72 0,97 - -6,13 0,00 0,00 -35,71
324 Facade N Utility Building 87,43 37,00 37,28 390,90 63,20 3,00 1706,13 -75,63 0,85 -3,50 -8,15 0,00 0,00 -20,22
325 Facade N, doors Utility Building 87,43 30,00 51,96 22,00 65,38 3,00 1705,12 -75,63 2,08 -4,50 - 0,00 0,00 -25,84
328 Facade S Utility Building 87,43 37,00 37,28 392,52 63,22 3,00 1717,25 -75,69 1,12 - -6,06 0,00 0,00 -34,96
329 Facade S, doors Utility Building 87,43 30,00 51,96 22,00 65,38 3,00 1718,42 -75,69 2,14 - - 0,00 0,00 -43,70
327 Facade W Utility Building 87,43 37,00 37,28 115,70 57,92 3,00 1701,02 -75,61 0,85 -3,58 -8,09 0,00 0,00 -25,52
319 Roof Utility Building 87,43 37,00 37,28 595,39 65,03 0,00 1711,59 -75,66 0,62 -4,62 -7,49 0,00 0,00 -22,12
351 Air condition unit I Workshop/Stores Building 0,00 0,00 87,00 87,00 0,00 1724,65 -75,73 -0,16 - -2,60 4,17 0,00 -3,32
352 Air condition unit II Workshop/Stores Building 0,00 0,00 87,00 87,00 0,00 1726,04 -75,73 -0,16 - -2,55 4,90 0,00 -3,74
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.16 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
Name 2 Konstantinato Ln = 25,6 dB(A)
347 Air condition unit I Administration Building 0,00 0,00 87,00 87,00 0,00 2123,23 -77,53 -0,42 -5,70 -4,11 0,00 0,00 -0,76
348 Air condition unit II Administration Building 0,00 0,00 87,00 87,00 0,00 2118,37 -77,51 -0,52 -6,14 -3,93 0,00 0,00 -1,10
349 Air condition unit III Administration Building 0,00 0,00 87,00 87,00 0,00 2107,56 -77,47 -0,69 -2,76 -5,04 3,09 0,00 4,14
350 Air condition unit IV Administration Building 0,00 0,00 87,00 87,00 0,00 2109,66 -77,48 -0,69 -2,76 -5,04 2,54 0,00 3,57
10 Building vent., exhaust 1 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 2109,14 -77,47 0,89 -4,10 -3,62 0,00 0,00 1,70
11 Building vent., exhaust 2 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 2112,28 -77,49 0,89 -4,07 -3,59 2,28 0,00 4,03
12 Building vent., exhaust 3 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 2118,93 -77,51 0,92 -4,20 -3,75 2,53 0,00 3,99
13 Building vent., exhaust 4 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 2122,26 -77,53 0,92 -4,20 -3,75 2,53 0,00 3,97
5 Facade N, GT air intake Compressor Building Unit 1 0,00 0,00 74,26 3,75 80,00 3,00 2122,36 -77,53 0,43 - -0,69 0,61 0,00 -5,26
4 Facade N, build. vent. air intlet Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 2117,12 -77,51 1,99 -9,00 -0,63 0,00 0,00 -13,08
3 Facade N, large door Compressor Building Unit 1 94,00 30,00 59,73 15,57 71,66 3,00 2126,64 -77,55 1,64 - -3,36 0,00 0,00 -23,40
6 Facade N, package ventilation, air inlet Compressor Building Unit 1 0,00 0,00 74,02 2,50 78,00 3,00 2122,36 -77,53 3,93 -9,27 -0,29 0,56 0,00 -1,60
22 Facade S, build. vent. air inlet Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 2108,02 -77,47 2,00 -4,16 -3,05 0,00 0,00 -10,61
21 Facade S, door Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 2114,28 -77,50 1,69 -4,46 -7,90 0,00 0,00 -17,14
7 Facade S, small door Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 2129,17 -77,56 1,70 - -3,35 0,00 0,00 -27,34
18 Facade W, build. vent. air inlet I Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 2111,75 -77,48 1,99 -4,16 -3,04 0,00 0,00 -10,63
19 Facade W, build. vent. air inlet II Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 2103,91 -77,45 1,99 -4,16 -3,04 0,00 0,00 -10,59
15 Facade W, door 1 Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 2113,64 -77,49 1,67 -4,46 -7,89 0,00 0,00 -17,16
16 Facade W, door 2 Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 2101,72 -77,44 1,67 -4,45 -7,87 0,00 0,00 -17,08
17 Facade W, package ventilation outlet Compressor Building Unit 1 0,00 0,00 78,00 1,00 78,00 3,00 2107,04 -77,47 3,88 -3,85 -1,59 0,00 0,00 1,98
2 Facade north Compressor Building Unit 1 94,00 48,00 42,00 282,61 66,51 3,00 2122,23 -77,53 0,00 - -1,37 0,00 0,00 -21,12
20 Facade south Compressor Building Unit 1 94,00 48,00 42,00 304,43 66,84 3,00 2107,36 -77,47 0,04 -1,45 -4,37 0,00 0,00 -13,41
14 Facade west Compressor Building Unit 1 94,00 48,00 42,00 359,86 67,56 3,00 2107,95 -77,47 0,01 -1,38 -4,41 0,00 0,00 -12,68
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.17 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
8 Roof Compressor Building Unit 1 94,00 45,00 45,41 352,54 70,88 0,00 2115,54 -77,50 -1,06 -3,10 -3,27 0,00 0,00 -14,06
29 air intake duct Compressor Building Unit 1 0,00 0,00 80,00 80,00 0,00 2126,14 -77,54 0,23 -5,73 -1,02 0,70 0,00 -3,37
27 oil demister Compressor Building Unit 1 0,00 0,00 80,00 80,00 0,00 2107,84 -77,47 0,17 -0,02 -8,22 2,54 0,00 -3,00
9 roof, explosion panel Compressor Building Unit 1 94,00 16,00 74,24 100,10 94,24 0,00 2115,85 -77,50 -0,67 -3,60 -4,75 2,06 0,00 9,78
40 Building vent., exhaust 1 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 2168,39 -77,71 1,08 -4,16 -3,75 0,00 0,00 1,45
41 Building vent., exhaust 2 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 2171,44 -77,73 1,08 -4,13 -3,72 0,00 0,00 1,51
42 Building vent., exhaust 3 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 2178,34 -77,75 1,11 -4,26 -3,88 0,00 0,00 1,21
43 Building vent., exhaust 4 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 2181,57 -77,77 1,11 -4,26 -3,88 0,00 0,00 1,20
35 Facade N, GT air intake Compressor Building Unit 3 0,00 0,00 74,26 3,75 80,00 3,00 2181,45 -77,77 0,50 - -0,71 0,00 0,00 -5,94
34 Facade N, build. vent. air intlet Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 2176,11 -77,75 2,06 -8,93 -0,66 0,00 0,00 -13,20
33 Facade N, large door Compressor Building Unit 3 94,00 30,00 59,73 15,57 71,66 3,00 2185,80 -77,78 1,74 - -3,44 0,00 0,00 -23,50
36 Facade N, package ventilation, air inlet Compressor Building Unit 3 0,00 0,00 74,02 2,50 78,00 3,00 2181,45 -77,77 3,96 -9,14 -0,30 0,00 0,00 -2,24
52 Facade S, build. vent. air inlet Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 2167,50 -77,71 2,07 -2,66 -2,02 0,00 0,00 -8,25
51 Facade S, door Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 2173,87 -77,74 1,79 -3,25 -6,98 0,00 0,00 -15,15
37 Facade S, small door Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 2188,37 -77,79 1,80 - -3,42 0,00 0,00 -27,46
48 Facade W, build. vent. air inlet I Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 2170,81 -77,72 2,06 -4,21 -3,08 0,00 0,00 -10,89
49 Facade W, build. vent. air inlet II Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 2163,17 -77,69 2,06 -1,92 -1,87 0,00 0,00 -7,36
45 Facade W, door 1 Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 2172,65 -77,73 1,77 -4,49 -8,05 0,00 0,00 -17,48
46 Facade W, door 2 Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 2161,04 -77,69 1,77 -3,34 -6,96 0,00 0,00 -15,19
47 Facade W, package ventilation outlet Compressor Building Unit 3 0,00 0,00 78,00 1,00 78,00 3,00 2166,22 -77,71 3,91 -0,99 -0,69 0,00 0,00 5,52
32 Facade north Compressor Building Unit 3 94,00 48,00 42,00 282,61 66,51 3,00 2181,31 -77,77 0,24 - -1,48 0,00 0,00 -20,79
50 Facade south Compressor Building Unit 3 94,00 48,00 42,00 304,43 66,84 3,00 2166,83 -77,71 0,22 -1,67 -4,03 0,00 0,00 -13,35
44 Facade west Compressor Building Unit 3 94,00 48,00 42,00 359,86 67,56 3,00 2167,11 -77,71 0,27 -1,43 -4,34 0,00 0,00 -12,64
38 Roof Compressor Building Unit 3 94,00 45,00 45,41 352,54 70,88 0,00 2174,77 -77,74 -0,85 -3,23 -3,39 0,00 0,00 -14,34
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.18 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
57 air intake duct Compressor Building Unit 3 0,00 0,00 80,00 80,00 0,00 2184,89 -77,78 0,41 -6,05 -1,02 0,00 0,00 -4,45
56 oil demister Compressor Building Unit 3 0,00 0,00 80,00 80,00 0,00 2167,02 -77,71 0,45 -4,11 -6,58 3,71 0,00 -4,24
39 roof, explosion panel Compressor Building Unit 3 94,00 16,00 74,24 100,10 94,24 0,00 2175,13 -77,74 -0,43 -3,72 -4,89 0,00 0,00 7,46
69 Building vent., exhaust 1 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 2184,26 -77,78 1,13 -4,19 -3,81 0,00 0,00 1,35
70 Building vent., exhaust 2 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 2187,28 -77,79 1,13 -4,18 -3,79 0,00 0,00 1,37
71 Building vent., exhaust 3 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 2193,94 -77,82 1,16 -4,28 -3,92 0,00 0,00 1,14
72 Building vent., exhaust 4 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 2197,55 -77,83 1,16 -4,28 -3,92 0,00 0,00 1,13
80 Facade E, build. vent. air inlet I Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 2194,70 -77,82 2,09 - -0,57 0,00 0,00 -16,17
81 Facade E, build. vent. air inlet II Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 2202,22 -77,85 2,09 - -0,61 0,00 0,00 -19,09
78 Facade E, door 1 Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 2192,91 -77,81 1,82 - -3,87 0,00 0,00 -24,55
77 Facade E, door 2 Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 2204,33 -77,86 1,82 - -3,62 0,00 0,00 -29,36
79 Facade E, package ventilation, air ou Compressor Building Unit 4 0,00 0,00 78,00 1,00 78,00 3,00 2199,21 -77,84 3,92 - -0,29 0,00 0,00 -4,41
64 Facade N, GT air intake Compressor Building Unit 4 0,00 0,00 74,26 3,75 80,00 3,00 2198,06 -77,83 0,52 - -0,67 0,00 0,00 -9,05
63 Facade N, build. vent. air inlet Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 2203,04 -77,85 2,09 - -0,60 0,00 0,00 -19,10
62 Facade N, large door Compressor Building Unit 4 94,00 30,00 59,73 15,57 71,66 3,00 2192,98 -77,81 1,76 - -3,59 0,00 0,00 -24,95
65 Facade N, package ventilation, air i Compressor Building Unit 4 0,00 0,00 74,02 2,50 78,00 3,00 2198,06 -77,83 3,96 - -0,30 0,00 0,00 -5,35
66 Facade N, small door Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 2190,87 -77,80 1,80 - -3,60 0,00 0,00 -28,34
75 Facade S, build. vent. air inlet Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 2183,45 -77,77 2,08 -1,54 -2,19 0,00 0,00 -7,35
74 Facade S, door Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 2177,45 -77,75 1,80 -3,15 -7,02 0,00 0,00 -15,10
76 Facade east Compressor Building Unit 4 94,00 48,00 42,00 359,86 67,56 3,00 2198,50 -77,83 0,30 - -1,39 0,00 0,00 -21,12
61 Facade north Compressor Building Unit 4 94,00 48,00 42,00 282,61 66,51 3,00 2198,50 -77,83 0,28 - -1,26 0,00 0,00 -23,57
73 Facade south Compressor Building Unit 4 94,00 48,00 42,00 304,43 66,84 3,00 2183,96 -77,78 0,29 -1,47 -4,37 0,00 0,00 -13,49
67 Roof Compressor Building Unit 4 94,00 45,00 45,41 352,54 70,88 0,00 2190,91 -77,80 -0,80 -3,28 -3,43 0,00 0,00 -14,43
86 air intake duct Compressor Building Unit 4 0,00 0,00 80,00 80,00 0,00 2200,31 -77,84 0,42 - -0,67 0,00 0,00 -8,72
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.19 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
85 oil demister Compressor Building Unit 4 0,00 0,00 80,00 80,00 0,00 2199,98 -77,84 0,60 - -4,06 0,00 0,00 -16,96
68 roof, explosion panel Compressor Building Unit 4 94,00 16,00 74,24 100,10 94,24 0,00 2191,31 -77,81 -0,37 -3,75 -4,94 0,00 0,00 7,37
98 Building vent., exhaust 1 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 2228,21 -77,95 1,26 -4,22 -3,88 0,00 0,00 1,21
99 Building vent., exhaust 2 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 2231,18 -77,96 1,26 -4,19 -3,85 0,00 0,00 1,26
100 Building vent., exhaust 3 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 2238,32 -77,99 1,29 -4,32 -4,02 0,00 0,00 0,96
101 Building vent., exhaust 4 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 2241,46 -78,00 1,29 -4,32 -4,02 0,00 0,00 0,95
93 Facade N, GT air intake Compressor Building Unit 5 0,00 0,00 74,26 3,75 80,00 3,00 2241,11 -78,00 0,56 - -0,74 0,00 0,00 -6,02
92 Facade N, build. vent. air intlet Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 2235,69 -77,98 2,12 -8,85 -0,69 0,00 0,00 -13,33
91 Facade N, large door Compressor Building Unit 5 94,00 30,00 59,73 15,57 71,66 3,00 2245,53 -78,02 1,84 - -3,52 0,00 0,00 -23,59
94 Facade N, package ventilation, air inlet Compressor Building Unit 5 0,00 0,00 74,02 2,50 78,00 3,00 2241,11 -78,00 3,98 -9,01 -0,30 0,00 0,00 -2,33
110 Facade S, build. vent. air inlet Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 2227,55 -77,95 2,13 -4,24 -3,13 0,00 0,00 -11,12
109 Facade S, door Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 2234,02 -77,97 1,89 -4,51 -8,21 0,00 0,00 -17,79
95 Facade S, small door Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 2248,14 -78,03 1,89 - -3,50 0,00 0,00 -27,58
106 Facade W, build. vent. air inlet I Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 2230,45 -77,96 2,12 -4,24 -3,12 0,00 0,00 -11,14
107 Facade W, build. vent. air inlet II Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 2223,02 -77,93 2,12 -4,24 -3,12 0,00 0,00 -11,11
103 Facade W, door 1 Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 2232,24 -77,97 1,87 -4,51 -8,20 0,00 0,00 -17,79
104 Facade W, door 2 Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 2220,95 -77,92 1,87 -4,50 -8,18 0,00 0,00 -17,72
105 Facade W, package ventilation outlet Compressor Building Unit 5 0,00 0,00 78,00 1,00 78,00 3,00 2225,99 -77,94 3,93 -3,92 -1,60 0,00 0,00 1,47
90 Facade north Compressor Building Unit 5 94,00 48,00 42,00 282,61 66,51 3,00 2240,95 -78,00 0,37 - -1,54 0,00 0,00 -20,89
108 Facade south Compressor Building Unit 5 94,00 48,00 42,00 304,43 66,84 3,00 2226,85 -77,95 0,39 -1,60 -4,60 0,00 0,00 -13,91
102 Facade west Compressor Building Unit 5 94,00 48,00 42,00 359,86 67,56 3,00 2226,88 -77,95 0,43 -1,57 -4,68 0,00 0,00 -13,20
96 Roof Compressor Building Unit 5 94,00 45,00 45,41 352,54 70,88 0,00 2234,64 -77,98 -0,64 -3,38 -3,50 0,00 0,00 -14,62
115 air intake duct Compressor Building Unit 5 0,00 0,00 80,00 80,00 0,00 2244,61 -78,01 0,47 -5,64 -1,13 0,00 0,00 -4,31
114 oil demister Compressor Building Unit 5 0,00 0,00 80,00 80,00 0,00 2227,24 -77,95 0,73 -4,33 -6,46 3,68 0,00 -4,33
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.20 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
97 roof, explosion panel Compressor Building Unit 5 94,00 16,00 74,24 100,10 94,24 0,00 2235,03 -77,98 -0,20 -3,85 -5,06 0,00 0,00 7,15
340 Facade E Electrical Building 87,43 37,00 39,28 92,30 58,93 3,00 2236,04 -77,98 1,99 - -7,57 0,00 0,00 -39,23
341 Facade E, sec. 1 Electrical Building 87,43 37,00 39,28 127,16 60,33 3,00 2231,70 -77,96 1,97 - -7,66 0,00 0,00 -39,04
342 Facade E, sec. 2 Electrical Building 87,43 37,00 39,28 8,11 48,37 3,00 2221,47 -77,92 1,95 - -7,74 0,00 0,00 -51,02
343 Facade E, sec. 3 Electrical Building 87,43 37,00 39,28 58,38 56,94 3,00 2217,07 -77,91 1,94 - -7,66 0,00 0,00 -42,35
344 Facade E, sec. 4 Electrical Building 87,43 37,00 39,28 2,59 43,42 3,00 2211,88 -77,89 1,93 - -7,42 0,00 0,00 -57,33
345 Facade E, sec. 5 Electrical Building 87,43 37,00 39,28 67,56 57,58 3,00 2206,00 -77,86 1,92 - -7,45 0,00 0,00 -45,00
334 Facade S, sec. 1 Electrical Building 87,43 37,00 39,28 72,39 57,88 3,00 2192,44 -77,81 1,92 -2,99 -8,95 0,00 0,00 -26,95
336 Facade S, sec. 2 Electrical Building 87,43 37,00 39,28 5,65 46,80 3,00 2199,05 -77,84 1,93 - -7,84 0,00 0,00 -44,48
337 Facade S, sec. 3 Electrical Building 87,43 37,00 39,28 48,15 56,11 3,00 2203,58 -77,85 1,94 -3,98 -9,87 0,00 0,00 -30,66
338 Facade S, sec. 4 Electrical Building 87,43 37,00 39,28 6,42 47,36 3,00 2207,29 -77,87 1,95 -3,99 -9,88 0,00 0,00 -39,44
339 Facade S, sec. 5 Electrical Building 87,43 37,00 39,28 131,91 60,48 3,00 2218,18 -77,91 1,97 -4,00 -9,92 0,00 0,00 -26,38
346 Facade W Electrical Building 87,43 37,00 39,28 97,41 59,17 3,00 2193,20 -77,81 1,91 - -7,31 0,00 0,00 -36,72
335 Roof Electrical Building 87,43 37,00 39,28 1181,57 70,01 0,00 2214,53 -77,90 1,86 -4,74 -9,44 0,00 0,00 -20,22
117 Filter I Filter 0,00 0,00 69,83 5,21 77,00 0,00 2048,73 -77,22 0,80 -0,57 -7,84 0,00 0,00 -7,82
118 Filter II Filter 0,00 0,00 69,82 5,22 77,00 0,00 2041,40 -77,19 0,79 -0,56 -7,81 0,00 0,00 -7,76
119 Filter IV Filter 0,00 0,00 69,80 5,25 77,00 0,00 2026,62 -77,13 0,77 -0,54 -7,74 0,00 0,00 -7,64
120 Filter V Filter 0,00 0,00 69,80 5,25 77,00 0,00 2019,31 -77,10 0,75 -0,53 -7,71 0,00 0,00 -7,58
122 Explosion relief panel Fuel Gas Skid I 87,00 16,00 66,62 30,00 81,39 0,00 1999,12 -77,01 -0,17 -3,90 -5,06 0,00 0,00 -4,75
125 Fuel Gas Skid, facade E Fuel Gas Skid I 87,00 37,00 45,32 126,06 66,33 3,00 2002,15 -77,02 0,39 -3,83 -5,75 0,00 0,00 -16,88
126 Fuel Gas Skid, facade E, door Fuel Gas Skid I 87,00 30,00 57,56 4,84 64,41 3,00 2005,46 -77,04 1,54 - -4,67 0,00 0,00 -32,37
123 Fuel Gas Skid, facade S Fuel Gas Skid I 87,00 37,00 45,32 61,38 63,20 3,00 1994,45 -76,99 0,39 -1,79 -5,98 0,00 0,00 -18,16
124 Fuel Gas Skid, facade S, door Fuel Gas Skid I 87,00 37,00 45,32 7,04 53,80 3,00 1994,53 -76,99 0,80 -4,41 -5,56 0,00 0,00 -29,36
128 Fuel Gas Skid, facade W Fuel Gas Skid I 87,00 37,00 45,32 130,90 66,49 3,00 1995,73 -76,99 0,25 -1,62 -6,19 0,00 0,00 -15,07
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.21 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
121 Fuel Gas Skid, roof Fuel Gas Skid I 87,00 37,00 45,32 93,97 65,05 0,00 1999,19 -77,01 0,25 -4,41 -5,44 0,00 0,00 -21,56
127 Ventilation, intake Fuel Gas Skid I 0,00 0,00 68,00 68,00 6,01 2003,63 -77,03 -4,74 - -4,67 0,00 0,00 -24,33
129 Ventilation, outlet Fuel Gas Skid I 0,00 0,00 68,00 68,00 6,01 1992,71 -76,98 -4,74 0,00 -4,65 0,00 0,00 -12,36
131 Explosion relief panel Fuel Gas Skid II 87,00 16,00 66,62 30,00 81,39 0,00 2008,16 -77,05 -0,17 -3,90 -5,07 0,00 0,00 -4,81
132 Fuel Gas Skid, facade E Fuel Gas Skid II 87,00 37,00 45,32 126,06 66,33 3,00 2011,65 -77,06 0,39 -4,29 -5,75 0,00 0,00 -17,39
133 Fuel Gas Skid, facade E, door Fuel Gas Skid II 87,00 37,00 45,32 4,84 52,17 3,00 2008,68 -77,05 0,81 - -3,97 0,00 0,00 -43,85
135 Fuel Gas Skid, facade N Fuel Gas Skid II 87,00 37,00 45,32 63,58 63,35 3,00 2012,76 -77,07 0,35 -3,55 -5,76 0,00 0,00 -19,67
136 Fuel Gas Skid, facade N, door Fuel Gas Skid II 87,00 37,00 45,32 4,84 52,17 3,00 2012,69 -77,07 0,80 - -4,46 0,00 0,00 -39,03
137 Fuel Gas Skid, facade W Fuel Gas Skid II 87,00 37,00 45,32 130,90 66,49 3,00 2004,89 -77,03 0,25 -1,83 -6,17 0,00 0,00 -15,30
130 Fuel Gas Skid, roof Fuel Gas Skid II 87,00 37,00 45,32 93,97 65,05 0,00 2008,12 -77,05 0,25 -4,41 -5,46 0,00 0,00 -21,61
134 Ventilation, intake Fuel Gas Skid II 0,00 0,00 68,00 68,00 6,01 2014,47 -77,08 -4,74 - -4,70 0,00 0,00 -24,43
138 Ventilation, outlet Fuel Gas Skid II 0,00 0,00 68,00 68,00 6,01 2001,84 -77,02 -4,74 0,00 -4,67 0,00 0,00 -12,42
296 Meter Run I Metering 0,00 0,00 72,70 39,44 88,66 0,00 2020,28 -77,10 1,97 -2,81 - 0,02 0,00 -0,12
297 Meter Run II Metering 0,00 0,00 72,70 39,45 88,66 0,00 2017,88 -77,09 1,97 -2,80 - 0,03 0,00 -0,08
298 Meter Run IV Metering 0,00 0,00 72,70 39,50 88,66 0,00 2013,02 -77,07 1,96 -2,77 - 0,03 0,00 -0,03
299 Meter Run V Metering 0,00 0,00 72,70 39,48 88,66 0,00 2010,59 -77,06 1,95 -2,76 - 0,35 0,00 0,31
143 Header discharge side Piping 0,00 0,00 80,00 136,93 101,37 0,00 2110,42 -77,48 1,38 -3,77 -7,80 0,36 0,00 14,06
233 Header discharge side Piping 0,00 0,00 80,00 89,78 99,53 0,00 2197,13 -77,83 1,52 -3,97 -8,29 1,07 0,00 12,04
234 Header suction side Piping 0,00 0,00 78,00 93,78 97,72 0,00 2194,28 -77,82 1,52 -3,96 -8,29 0,50 0,00 9,68
144 Header suction side Piping 0,00 0,00 78,00 108,68 98,36 0,00 2113,94 -77,49 1,39 -3,76 -7,87 0,38 0,00 11,00
300 Facade E Power Generation Gas I 97,00 37,00 58,49 36,27 74,09 3,00 2063,02 -77,28 0,21 - -2,71 0,00 0,00 -14,09
302 Facade N Power Generation Gas I 97,00 37,00 58,49 58,24 76,15 3,00 2060,60 -77,27 0,15 - -2,69 0,00 0,00 -12,25
305 Facade S Power Generation Gas I 97,00 37,00 58,49 53,44 75,77 3,00 2055,59 -77,25 0,20 -4,00 -4,39 0,00 0,00 -6,67
306 Facade S, door Power Generation Gas I 97,00 30,00 64,01 4,84 70,86 3,00 2054,38 -77,25 0,95 -4,26 -5,36 0,00 0,00 -12,05
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.22 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
303 Facade W Power Generation Gas I 97,00 37,00 58,49 36,05 74,06 3,00 2053,02 -77,24 0,17 -4,08 -4,35 0,00 0,00 -8,45
308 Power Generation Gas I, Exhaust Stack Power Generation Gas I 0,00 0,00 90,00 90,00 0,00 2063,67 -77,28 -0,26 -1,07 -3,54 0,00 0,00 7,84
301 Roof Power Generation Gas I 97,00 37,00 58,49 104,04 78,67 0,00 2058,07 -77,26 -0,34 -4,00 -4,17 0,00 0,00 -7,10
304 Room ventilation, intake Power Generation Gas I 0,00 0,00 76,00 76,00 6,01 2052,39 -77,24 -4,75 0,00 -4,79 0,00 0,00 -4,77
307 Room ventilation, outlet Power Generation Gas I 0,00 0,00 76,00 76,00 6,01 2057,16 -77,26 -4,75 0,00 -4,80 0,00 0,00 -4,80
313 Facade E Power Generation Gas II 97,00 37,00 58,49 36,40 74,11 3,00 2075,86 -77,34 0,21 - -2,73 0,00 0,00 -14,11
314 Facade N Power Generation Gas II 97,00 37,00 58,49 53,35 75,77 3,00 2073,38 -77,33 0,13 - -2,80 0,00 0,00 -12,28
315 Facade N, door Power Generation Gas II 97,00 30,00 64,01 4,84 70,86 3,00 2074,57 -77,33 0,96 - -1,89 0,00 0,00 -18,25
312 Facade S Power Generation Gas II 97,00 37,00 63,49 58,05 81,13 3,00 2068,29 -77,30 0,32 -4,14 -4,40 0,00 0,00 -1,39
309 Facade W Power Generation Gas II 97,00 37,00 58,49 36,20 74,08 3,00 2065,95 -77,29 0,18 -4,10 -4,37 0,00 0,00 -8,51
317 Power Generation Gas II, Exhaust Stack Power Generation Gas II 0,00 0,00 90,00 90,00 0,00 2076,20 -77,34 -0,26 -1,11 -3,55 0,00 0,00 7,74
311 Roof Power Generation Gas II 97,00 37,00 58,49 104,19 78,67 0,00 2070,95 -77,32 -0,34 -4,00 -4,19 0,00 0,00 -7,17
310 Room ventilation, intake Power Generation Gas II 0,00 0,00 76,00 76,00 6,01 2065,33 -77,29 -4,75 0,00 -4,82 0,00 0,00 -4,85
316 Room ventilation, outlet Power Generation Gas II 0,00 0,00 76,00 76,00 6,01 2071,82 -77,32 -4,75 - -4,83 0,00 0,00 -16,02
159 Distrib. pipe 1 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2061,87 -77,28 2,02 -0,61 - 0,00 0,00 -16,10
146 Distrib. pipe 1 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2075,17 -77,33 1,97 -1,53 - 0,00 0,00 -13,00
160 Distrib. pipe 2 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2062,63 -77,28 2,02 -0,61 - 0,00 0,00 -16,11
148 Distrib. pipe 2 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2075,93 -77,34 1,97 -1,54 - 0,00 0,00 -13,05
161 Distrib. pipe 3 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2063,39 -77,28 2,03 -0,61 - 0,00 0,00 -16,11
149 Distrib. pipe 3 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2076,73 -77,34 1,98 -1,54 - 0,00 0,00 -13,06
162 Distrib. pipe 4 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2064,33 -77,29 2,03 -0,61 - 0,00 0,00 -16,11
150 Distrib. pipe 4 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2077,56 -77,34 1,98 -1,54 - 0,00 0,00 -13,08
163 Distrib. pipe 5 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2065,10 -77,29 2,04 -0,61 - 0,00 0,00 -16,12
151 Distrib. pipe 5 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2078,31 -77,35 1,99 -1,54 - 0,00 0,00 -13,09
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.23 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
164 Distrib. pipe 6 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2065,85 -77,29 2,04 -0,61 - 0,00 0,00 -16,12
152 Distrib. pipe 6 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2079,12 -77,35 1,99 -1,54 - 0,00 0,00 -13,10
165 Distrib. pipe 7 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2066,77 -77,30 2,05 -0,61 - 0,00 0,00 -16,13
153 Distrib. pipe 7 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2080,03 -77,35 2,00 -1,54 - 0,00 0,00 -13,11
166 Distrib. pipe 8 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2067,54 -77,30 2,05 -0,61 - 0,00 0,00 -16,13
154 Distrib. pipe 8 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2080,78 -77,36 2,00 -1,54 - 0,00 0,00 -13,11
167 Distrib. pipe 9 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2068,29 -77,30 2,06 -0,61 - 0,00 0,00 -16,13
155 Distrib. pipe 9 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2081,59 -77,36 2,00 -1,49 - 0,00 0,00 -12,92
168 Distrib. pipe 10 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2069,23 -77,31 2,06 -0,61 - 0,00 0,00 -16,14
156 Distrib. pipe 10 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2082,48 -77,36 2,01 -1,49 - 0,00 0,00 -12,93
169 Distrib. pipe 11 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2070,00 -77,31 2,06 -0,61 - 0,00 0,00 -16,14
157 Distrib. pipe 11 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2083,23 -77,37 2,01 -1,50 - 0,00 0,00 -12,96
170 Distrib. pipe 12 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2070,75 -77,31 2,07 -0,61 - 0,00 0,00 -16,15
158 Distrib. pipe 12 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2084,04 -77,37 2,02 -1,50 - 0,00 0,00 -12,98
295 Header discharge side, Start Up Cooler Start Up Cooler 0,00 0,00 80,00 94,83 99,77 0,00 2191,61 -77,81 1,52 -3,95 -8,28 0,42 0,00 11,66
229 Header discharge side, Start Up Cooler Start Up Cooler 0,00 0,00 80,00 164,54 102,16 0,00 2100,81 -77,44 1,37 -3,68 -7,65 0,21 0,00 14,97
140 Start Up Cooler Start Up Cooler 0,00 0,00 66,17 191,91 89,00 0,00 2071,81 -77,32 0,77 -0,16 -8,55 0,00 0,00 3,74
142 Start Up Cooler, gas flow noise Start Up Cooler 0,00 0,00 70,16 192,32 93,00 0,00 2071,81 -77,32 0,77 -0,16 -8,55 0,00 0,00 7,74
147 Distrib. pipe 1 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2072,44 -77,32 2,12 -0,71 - 0,00 0,00 -17,13
293 Distrib. pipe 1 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2109,54 -77,48 2,24 -0,74 - 0,00 0,00 -17,40
200 Distrib. pipe 2 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2073,20 -77,32 2,12 -0,71 - 0,00 0,00 -17,14
294 Distrib. pipe 2 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2110,31 -77,48 2,25 -0,74 - 0,00 0,00 -17,40
201 Distrib. pipe 3 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2073,97 -77,33 2,12 -0,71 - 0,00 0,00 -17,14
265 Distrib. pipe 3 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2111,08 -77,48 2,25 -0,74 - 0,00 0,00 -17,41
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.24 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
202 Distrib. pipe 4 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2074,89 -77,33 2,13 -0,71 - 0,00 0,00 -17,15
266 Distrib. pipe 4 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2112,02 -77,49 2,25 -0,75 - 0,00 0,00 -17,42
267 Distrib. pipe 5 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2112,79 -77,49 2,25 -0,75 - 0,00 0,00 -17,43
203 Distrib. pipe 5 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2075,66 -77,34 2,13 -0,71 - 0,00 0,00 -17,15
268 Distrib. pipe 6 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2113,56 -77,49 2,25 -0,75 - 0,00 0,00 -17,44
204 Distrib. pipe 6 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2076,42 -77,34 2,13 -0,71 - 0,00 0,00 -17,16
269 Distrib. pipe 7 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2114,51 -77,50 2,25 -0,75 - 0,00 0,00 -17,45
205 Distrib. pipe 7 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2077,36 -77,34 2,14 -0,71 - 0,00 0,00 -17,16
206 Distrib. pipe 8 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2078,12 -77,35 2,14 -0,71 - 0,00 0,00 -17,17
270 Distrib. pipe 8 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2115,28 -77,50 2,25 -0,75 - 0,00 0,00 -17,46
207 Distrib. pipe 9 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2078,89 -77,35 2,14 -0,71 - 0,00 0,00 -17,17
271 Distrib. pipe 9 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2116,05 -77,50 2,26 -0,75 - 0,00 0,00 -17,46
272 Distrib. pipe 10 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2116,99 -77,51 2,26 -0,75 - 0,00 0,00 -17,47
208 Distrib. pipe 10 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2079,82 -77,35 2,15 -0,71 - 0,00 0,00 -17,18
209 Distrib. pipe 11 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2080,58 -77,36 2,15 -0,71 - 0,00 0,00 -17,18
273 Distrib. pipe 11 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2117,76 -77,51 2,26 -0,75 - 0,00 0,00 -17,48
210 Distrib. pipe 12 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2081,34 -77,36 2,15 -0,71 - 0,00 0,00 -17,19
274 Distrib. pipe 12 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2118,53 -77,51 2,26 -0,75 - 0,00 0,00 -17,49
211 Distrib. pipe 13 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2082,26 -77,36 2,16 -0,71 - 0,00 0,00 -17,19
275 Distrib. pipe 13 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2119,46 -77,52 2,26 -0,76 - 0,00 0,00 -17,50
212 Distrib. pipe 14 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2083,03 -77,37 2,16 -0,71 - 0,00 0,00 -17,20
276 Distrib. pipe 14 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2120,23 -77,52 2,26 -0,76 - 0,00 0,00 -17,51
213 Distrib. pipe 15 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2083,79 -77,37 2,16 -0,71 - 0,00 0,00 -17,20
277 Distrib. pipe 15 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2121,00 -77,52 2,26 -0,76 - 0,00 0,00 -17,51
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.25 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
278 Distrib. pipe 16 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2121,94 -77,53 2,27 -0,76 - 0,00 0,00 -17,52
214 Distrib. pipe 16 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2084,72 -77,37 2,17 -0,71 - 0,00 0,00 -17,21
215 Distrib. pipe 17 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2085,49 -77,38 2,17 -0,71 - 0,00 0,00 -17,21
279 Distrib. pipe 17 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2122,71 -77,53 2,27 -0,76 - 0,00 0,00 -17,53
216 Distrib. pipe 18 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2086,25 -77,38 2,17 -0,71 - 0,00 0,00 -17,22
280 Distrib. pipe 18 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2123,49 -77,53 2,27 -0,76 - 0,00 0,00 -17,54
217 Distrib. pipe 19 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2087,20 -77,38 2,18 -0,71 - 0,00 0,00 -17,22
281 Distrib. pipe 19 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2124,44 -77,54 2,27 -0,76 - 0,00 0,00 -17,55
282 Distrib. pipe 20 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2125,21 -77,54 2,27 -0,76 - 0,00 0,00 -17,56
218 Distrib. pipe 20 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2087,96 -77,39 2,18 -0,71 - 0,00 0,00 -17,23
283 Distrib. pipe 21 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2125,98 -77,54 2,27 -0,76 - 0,00 0,00 -17,57
219 Distrib. pipe 21 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2088,73 -77,39 2,18 -0,71 - 0,00 0,00 -17,23
220 Distrib. pipe 22 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2089,66 -77,39 2,18 -0,71 - 0,00 0,00 -17,24
284 Distrib. pipe 22 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2126,92 -77,55 2,27 -0,77 - 0,00 0,00 -17,58
285 Distrib. pipe 23 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2127,69 -77,55 2,28 -0,77 - 0,00 0,00 -17,59
221 Distrib. pipe 23 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2090,42 -77,40 2,19 -0,71 - 0,00 0,00 -17,24
222 Distrib. pipe 24 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2091,19 -77,40 2,19 -0,72 - 0,00 0,00 -17,25
286 Distrib. pipe 24 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2128,47 -77,55 2,28 -0,77 - 0,00 0,00 -17,59
287 Distrib. pipe 25 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2129,43 -77,56 2,28 -0,77 - 0,00 0,00 -17,60
223 Distrib. pipe 25 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2092,15 -77,40 2,19 -0,72 - 0,00 0,00 -17,26
224 Distrib. pipe 26 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2092,91 -77,41 2,20 -0,72 - 0,00 0,00 -17,26
288 Distrib. pipe 26 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2130,21 -77,56 2,28 -0,77 - 0,00 0,00 -17,61
289 Distrib. pipe 27 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2130,98 -77,56 2,28 -0,77 - 0,00 0,00 -17,62
225 Distrib. pipe 27 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2093,68 -77,41 2,20 -0,72 - 0,00 0,00 -17,27
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.26 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
290 Distrib. pipe 28 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2131,92 -77,57 2,28 -0,77 - 0,00 0,00 -17,63
226 Distrib. pipe 28 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2094,61 -77,41 2,20 -0,72 - 0,00 0,00 -17,27
227 Distrib. pipe 29 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2095,38 -77,42 2,20 -0,72 - 0,00 0,00 -17,28
291 Distrib. pipe 29 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2132,69 -77,57 2,28 -0,77 - 0,00 0,00 -17,64
292 Distrib. pipe 30 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2133,47 -77,57 2,29 -0,77 - 0,00 0,00 -17,65
228 Distrib. pipe 30 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2096,14 -77,42 2,21 -0,72 - 0,00 0,00 -17,28
139 Gas Cooler 1/2 Transportation Gas Cooler 0,00 0,00 66,05 495,71 93,00 0,00 2090,26 -77,40 0,91 -0,16 -8,61 0,00 0,00 7,74
145 Gas Cooler 1/2, distrib. pipe 1 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2083,28 -77,37 2,10 -2,23 - 0,00 0,00 -15,06
171 Gas Cooler 1/2, distrib. pipe 2 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2084,04 -77,37 2,11 -2,22 - 0,00 0,00 -15,04
172 Gas Cooler 1/2, distrib. pipe 3 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2084,81 -77,37 2,11 -2,22 - 0,00 0,00 -15,05
173 Gas Cooler 1/2, distrib. pipe 4 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2085,74 -77,38 2,11 -2,21 - 0,00 0,00 -14,93
174 Gas Cooler 1/2, distrib. pipe 5 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2086,49 -77,38 2,12 -2,18 - 0,00 0,00 -14,93
175 Gas Cooler 1/2, distrib. pipe 6 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2087,25 -77,38 2,12 -2,15 - 0,00 0,00 -14,86
176 Gas Cooler 1/2, distrib. pipe 7 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2088,17 -77,39 2,13 -2,09 - 0,00 0,00 -14,76
177 Gas Cooler 1/2, distrib. pipe 8 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2088,94 -77,39 2,13 -2,03 - 0,00 0,00 -14,66
178 Gas Cooler 1/2, distrib. pipe 9 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2089,70 -77,39 2,13 -1,93 - 0,00 0,00 -14,55
179 Gas Cooler 1/2, distrib. pipe 10 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2090,61 -77,40 2,14 -1,74 - 0,00 0,00 -14,40
180 Gas Cooler 1/2, distrib. pipe 11 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2091,37 -77,40 2,14 -1,52 - 0,00 0,00 -14,29
181 Gas Cooler 1/2, distrib. pipe 12 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2092,14 -77,40 2,14 -1,29 - 0,00 0,00 -14,06
182 Gas Cooler 1/2, distrib. pipe 13 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2093,08 -77,41 2,15 -0,70 - 0,00 0,00 -14,20
183 Gas Cooler 1/2, distrib. pipe 14 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2093,84 -77,41 2,15 -0,70 - 0,00 0,00 -14,21
184 Gas Cooler 1/2, distrib. pipe 15 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2094,60 -77,41 2,15 -0,70 - 0,00 0,00 -14,22
185 Gas Cooler 1/2, distrib. pipe 16 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2095,54 -77,42 2,16 -0,70 - 0,00 0,00 -14,22
186 Gas Cooler 1/2, distrib. pipe 17 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2096,30 -77,42 2,16 -0,70 - 0,00 0,00 -14,23
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.27 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
187 Gas Cooler 1/2, distrib. pipe 18 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2097,06 -77,42 2,16 -0,70 - 0,00 0,00 -14,23
188 Gas Cooler 1/2, distrib. pipe 19 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2097,96 -77,43 2,17 -0,70 - 0,00 0,00 -14,24
189 Gas Cooler 1/2, distrib. pipe 20 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2098,73 -77,43 2,17 -0,70 - 0,00 0,00 -14,24
190 Gas Cooler 1/2, distrib. pipe 21 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2099,49 -77,43 2,17 -0,70 - 0,00 0,00 -14,25
191 Gas Cooler 1/2, distrib. pipe 22 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2100,42 -77,44 2,18 -0,70 - 0,00 0,00 -14,26
192 Gas Cooler 1/2, distrib. pipe 23 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2101,18 -77,44 2,18 -0,70 - 0,00 0,00 -14,26
193 Gas Cooler 1/2, distrib. pipe 24 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2101,94 -77,44 2,18 -0,70 - 0,00 0,00 -14,27
194 Gas Cooler 1/2, distrib. pipe 25 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2102,87 -77,45 2,18 -0,70 - 0,00 0,00 -14,27
195 Gas Cooler 1/2, distrib. pipe 26 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2103,64 -77,45 2,19 -0,70 - 0,00 0,00 -14,28
196 Gas Cooler 1/2, distrib. pipe 27 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2104,40 -77,45 2,19 -0,70 - 0,00 0,00 -14,28
197 Gas Cooler 1/2, distrib. pipe 28 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2105,33 -77,46 2,19 -0,70 - 0,00 0,00 -14,29
198 Gas Cooler 1/2, distrib. pipe 29 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2106,09 -77,46 2,20 -0,70 - 0,00 0,00 -14,30
199 Gas Cooler 1/2, distrib. pipe 30 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2106,86 -77,46 2,20 -0,70 - 0,00 0,00 -14,30
141 Gas Cooler 1/2, gas flow noise Transportation Gas Cooler 0,00 0,00 66,05 495,71 93,00 0,00 2090,26 -77,40 0,91 -0,16 -8,61 0,00 0,00 7,74
231 Gas Cooler 3/4 Transportation Gas Cooler 0,00 0,00 66,04 496,15 93,00 0,00 2126,44 -77,55 1,16 -0,17 -8,74 0,00 0,00 7,71
235 Gas Cooler 3/4, distrib. pipe 1 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2120,19 -77,52 2,24 -0,70 - 0,00 0,00 -14,41
236 Gas Cooler 3/4, distrib. pipe 2 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2120,96 -77,52 2,24 -0,70 - 0,00 0,00 -14,42
237 Gas Cooler 3/4, distrib. pipe 3 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2121,73 -77,53 2,24 -0,70 - 0,00 0,00 -14,43
238 Gas Cooler 3/4, distrib. pipe 4 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2122,67 -77,53 2,24 -0,70 - 0,00 0,00 -14,43
239 Gas Cooler 3/4, distrib. pipe 5 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2123,43 -77,53 2,24 -0,70 - 0,00 0,00 -14,44
240 Gas Cooler 3/4, distrib. pipe 6 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2124,20 -77,54 2,25 -0,70 - 0,00 0,00 -14,45
241 Gas Cooler 3/4, distrib. pipe 7 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2125,13 -77,54 2,25 -0,71 - 0,00 0,00 -14,46
242 Gas Cooler 3/4, distrib. pipe 8 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2125,90 -77,54 2,25 -0,71 - 0,00 0,00 -14,46
243 Gas Cooler 3/4, distrib. pipe 9 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2126,67 -77,55 2,25 -0,71 - 0,00 0,00 -14,47
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.28 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
244 Gas Cooler 3/4, distrib. pipe 10 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2127,60 -77,55 2,25 -0,71 - 0,00 0,00 -14,48
245 Gas Cooler 3/4, distrib. pipe 11 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2128,37 -77,55 2,25 -0,71 - 0,00 0,00 -14,49
246 Gas Cooler 3/4, distrib. pipe 12 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2129,13 -77,56 2,25 -0,71 - 0,00 0,00 -14,49
247 Gas Cooler 3/4, distrib. pipe 13 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2130,08 -77,56 2,26 -0,71 - 0,00 0,00 -14,50
248 Gas Cooler 3/4, distrib. pipe 14 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2130,85 -77,56 2,26 -0,72 - 0,00 0,00 -14,51
249 Gas Cooler 3/4, distrib. pipe 15 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2131,62 -77,57 2,26 -0,72 - 0,00 0,00 -14,52
250 Gas Cooler 3/4, distrib. pipe 16 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2132,56 -77,57 2,26 -0,72 - 0,00 0,00 -14,53
251 Gas Cooler 3/4, distrib. pipe 17 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2133,33 -77,57 2,26 -0,72 - 0,00 0,00 -14,53
252 Gas Cooler 3/4, distrib. pipe 18 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2134,11 -77,58 2,26 -0,72 - 0,00 0,00 -14,54
253 Gas Cooler 3/4, distrib. pipe 19 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2135,02 -77,58 2,26 -0,72 - 0,00 0,00 -14,55
254 Gas Cooler 3/4, distrib. pipe 20 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2135,79 -77,58 2,27 -0,72 - 0,00 0,00 -14,56
255 Gas Cooler 3/4, distrib. pipe 21 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2136,56 -77,59 2,27 -0,72 - 0,00 0,00 -14,56
256 Gas Cooler 3/4, distrib. pipe 22 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2137,49 -77,59 2,27 -0,73 - 0,00 0,00 -14,57
257 Gas Cooler 3/4, distrib. pipe 23 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2138,26 -77,59 2,27 -0,73 - 0,00 0,00 -14,58
258 Gas Cooler 3/4, distrib. pipe 24 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2139,03 -77,60 2,27 -0,73 - 0,00 0,00 -14,59
259 Gas Cooler 3/4, distrib. pipe 25 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2139,98 -77,60 2,27 -0,73 - 0,00 0,00 -14,59
260 Gas Cooler 3/4, distrib. pipe 26 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2140,75 -77,60 2,27 -0,73 - 0,00 0,00 -14,60
261 Gas Cooler 3/4, distrib. pipe 27 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2141,52 -77,61 2,28 -0,73 - 0,00 0,00 -14,61
262 Gas Cooler 3/4, distrib. pipe 28 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2142,45 -77,61 2,28 -0,73 - 0,00 0,00 -14,62
263 Gas Cooler 3/4, distrib. pipe 29 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2143,22 -77,61 2,28 -0,73 - 0,00 0,00 -14,62
264 Gas Cooler 3/4, distrib. pipe 30 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2143,99 -77,62 2,28 -0,74 - 0,00 0,00 -14,63
232 Gas Cooler 3/4, gas flow noise Transportation Gas Cooler 0,00 0,00 66,04 496,10 93,00 0,00 2126,44 -77,55 1,16 -0,17 -8,74 0,00 0,00 7,71
230 Header Discharge side Transportation Gas Cooler 0,00 0,00 78,00 90,45 97,56 0,00 2077,90 -77,34 1,35 -3,60 -7,70 0,00 0,00 10,27
28 Control valve (enclosed) Unit 1 0,00 0,00 87,00 87,00 3,01 2103,82 -77,45 -4,75 0,00 -8,55 2,51 0,00 1,77
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.29 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
23 Exhaust Stack Opening Unit 1 0,00 0,00 84,97 2,01 88,00 0,00 2101,06 -77,44 1,30 -2,85 -2,30 0,00 0,00 6,71
24 Exhaust duct outsde compressor Unit 1 0,00 0,00 76,40 12,10 87,23 0,00 2103,98 -77,45 2,93 -3,73 -4,76 2,53 0,00 6,74
1 Oil Cooler Unit 1 0,00 0,00 78,11 24,50 92,00 0,00 2106,53 -77,46 1,09 -2,27 -6,73 2,52 0,00 9,14
25 Piping suction side Unit 1 0,00 0,00 78,00 34,38 93,36 0,00 2094,36 -77,41 1,34 -3,79 -8,09 0,34 0,00 5,76
26 Piping, discharge side Unit 1 0,00 0,00 80,00 30,25 94,81 0,00 2107,22 -77,47 1,36 -3,82 -8,11 1,64 0,00 8,41
58 Control valve (eingehaust) Unit 3 0,00 0,00 87,00 87,00 3,01 2163,17 -77,69 -4,76 0,47 -8,79 2,31 0,00 1,55
31 Exhaust Stack Opening Unit 3 0,00 0,00 84,97 2,01 88,00 0,00 2159,89 -77,68 1,43 -2,90 -2,38 0,00 0,00 6,48
53 Exhaust duct outsde compressor Unit 3 0,00 0,00 79,40 6,06 87,23 0,00 2162,88 -77,69 3,00 -1,83 -2,79 1,19 0,00 9,11
30 Oil Cooler Unit 3 0,00 0,00 78,11 24,50 92,00 0,00 2165,25 -77,70 1,19 -2,58 -6,68 2,27 0,00 8,49
54 Piping suction side Unit 3 0,00 0,00 78,00 34,38 93,36 0,00 2156,48 -77,67 1,45 -3,19 -7,70 0,21 0,00 6,47
55 Piping, discharge side Unit 3 0,00 0,00 80,00 30,25 94,81 0,00 2166,15 -77,71 1,46 -3,74 -7,99 1,22 0,00 8,06
87 Control valve (eingehaust) Unit 4 0,00 0,00 87,00 87,00 3,01 2178,63 -77,76 -4,76 0,00 -8,85 0,00 0,00 -1,35
60 Exhaust Stack Opening Unit 4 0,00 0,00 84,97 2,01 88,00 0,00 2202,07 -77,85 1,53 -2,93 -2,44 0,00 0,00 6,31
82 Exhaust duct outsde compressor Unit 4 0,00 0,00 79,58 5,82 87,23 0,00 2198,95 -77,84 3,04 - -0,37 0,00 0,00 1,82
59 Oil Cooler Unit 4 0,00 0,00 78,11 24,50 92,00 0,00 2206,84 -77,87 1,25 - -1,79 0,48 0,00 -1,10
83 Piping suction side Unit 4 0,00 0,00 78,00 34,38 93,36 0,00 2169,46 -77,72 1,47 -3,91 -8,22 1,98 0,00 6,98
84 Piping, discharge side Unit 4 0,00 0,00 80,00 30,25 94,81 0,00 2182,30 -77,77 1,49 -3,95 -8,25 2,30 0,00 8,62
116 Control valve (eingehaust) Unit 5 0,00 0,00 87,00 87,00 3,01 2223,40 -77,93 -4,76 0,00 -9,03 2,51 0,00 0,80
89 Exhaust Stack Opening Unit 5 0,00 0,00 84,97 2,01 88,00 0,00 2219,74 -77,92 1,57 -2,94 -2,46 0,00 0,00 6,25
111 Exhaust duct outsde compressor Unit 5 0,00 0,00 79,44 6,01 87,23 0,00 2222,77 -77,93 3,06 -3,97 -4,68 0,00 0,00 3,71
88 Oil Cooler Unit 5 0,00 0,00 78,11 24,50 92,00 0,00 2224,93 -77,94 1,28 -2,82 -6,67 2,51 0,00 8,36
112 Piping suction side Unit 5 0,00 0,00 78,00 34,38 93,36 0,00 2214,15 -77,90 1,54 -4,00 -8,32 0,29 0,00 4,98
113 Piping, discharge side Unit 5 0,00 0,00 80,00 30,25 94,81 0,00 2227,25 -77,95 1,56 -4,02 -8,35 1,27 0,00 7,33
330 Air compressor I, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 2150,08 -77,64 -4,76 0,11 -5,01 0,00 0,00 -14,29
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.30 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
331 Air compressor II, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 2151,60 -77,65 -4,76 0,22 -5,02 0,00 0,00 -14,19
332 Air compressor III, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 2153,12 -77,65 -4,76 0,36 -5,02 0,00 0,00 -14,06
320 Air compressor room, ventilation Utility Building 0,00 0,00 68,00 68,00 3,01 2152,16 -77,65 -4,70 -0,07 -5,02 0,00 0,00 -16,43
354 Air condition unit I Utility Building 0,00 0,00 87,00 87,00 0,00 2152,07 -77,65 0,20 -4,15 -4,68 2,41 0,00 3,14
353 Air condition unit II Utility Building 0,00 0,00 87,00 87,00 0,00 2152,83 -77,65 0,20 -4,16 -4,68 2,42 0,00 3,13
333 Boiler room, ventilation intake Utility Building 0,00 0,00 72,00 72,00 6,01 2180,65 -77,76 -4,76 1,30 -5,09 0,00 0,00 -8,29
326 Boiler room, ventilation outlet Utility Building 0,00 0,00 72,00 72,00 6,01 2160,06 -77,68 -4,74 - -5,04 0,00 0,00 -27,70
321 Boiler, stack opening I Utility Building 0,00 0,00 78,00 78,00 3,01 2183,25 -77,77 -4,70 -0,07 -5,09 0,00 0,00 -6,63
323 Boiler, stack opening III Utility Building 0,00 0,00 78,00 78,00 3,01 2187,11 -77,79 -4,70 -0,07 -5,10 0,00 0,00 -6,65
322 Boiler, stack opening Ii Utility Building 0,00 0,00 78,00 78,00 3,01 2185,18 -77,78 -4,70 -0,07 -5,10 0,00 0,00 -6,64
318 Facade E Utility Building 87,43 37,00 37,28 117,45 57,98 3,00 2186,39 -77,79 1,77 - -7,38 0,00 0,00 -40,80
324 Facade N Utility Building 87,43 37,00 37,28 390,90 63,20 3,00 2173,23 -77,73 1,69 - -7,59 0,00 0,00 -38,27
325 Facade N, doors Utility Building 87,43 30,00 51,96 22,00 65,38 3,00 2171,47 -77,73 2,27 - - 0,00 0,00 -48,35
328 Facade S Utility Building 87,43 37,00 37,28 392,52 63,22 3,00 2164,30 -77,70 1,69 -2,35 -9,43 0,00 0,00 -21,58
329 Facade S, doors Utility Building 87,43 30,00 51,96 22,00 65,38 3,00 2166,07 -77,71 2,27 -4,15 - 0,00 0,00 -28,48
327 Facade W Utility Building 87,43 37,00 37,28 115,70 57,92 3,00 2151,29 -77,65 1,59 -4,97 -9,01 0,00 0,00 -29,12
319 Roof Utility Building 87,43 37,00 37,28 595,39 65,03 0,00 2168,96 -77,72 1,21 -4,71 -9,20 0,00 0,00 -25,39
351 Air condition unit I Workshop/Stores Building 0,00 0,00 87,00 87,00 0,00 2091,77 -77,40 -0,28 -2,93 -5,06 2,53 0,00 3,87
352 Air condition unit II Workshop/Stores Building 0,00 0,00 87,00 87,00 0,00 2094,19 -77,41 -0,23 -2,97 -5,07 2,53 0,00 3,85
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.31 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
Name 3 Neochori Ln = 24,7 dB(A)
347 Air condition unit I Administration Building 0,00 0,00 87,00 87,00 0,00 2217,18 -77,91 -0,92 -3,34 -4,98 3,66 0,00 3,51
348 Air condition unit II Administration Building 0,00 0,00 87,00 87,00 0,00 2220,21 -77,92 -0,91 -3,35 -4,98 2,54 0,00 2,38
349 Air condition unit III Administration Building 0,00 0,00 87,00 87,00 0,00 2229,06 -77,95 -0,85 -3,90 -4,43 0,00 0,00 -0,14
350 Air condition unit IV Administration Building 0,00 0,00 87,00 87,00 0,00 2226,29 -77,94 -0,89 -2,31 -4,73 0,00 0,00 1,12
10 Building vent., exhaust 1 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 2279,37 -78,15 0,89 -4,10 -3,66 0,00 0,00 0,98
11 Building vent., exhaust 2 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 2274,81 -78,13 0,87 -4,12 -3,68 0,00 0,00 0,94
12 Building vent., exhaust 3 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 2274,23 -78,13 0,88 -5,62 -2,29 0,00 0,00 0,85
13 Building vent., exhaust 4 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 2269,29 -78,11 0,87 -4,13 -3,68 0,00 0,00 0,95
5 Facade N, GT air intake Compressor Building Unit 1 0,00 0,00 74,26 3,75 80,00 3,00 2264,23 -78,09 0,40 -2,85 -1,81 0,00 0,00 0,66
4 Facade N, build. vent. air intlet Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 2267,02 -78,10 1,97 -2,89 -2,16 0,00 0,00 -9,12
3 Facade N, large door Compressor Building Unit 1 94,00 30,00 59,73 15,57 71,66 3,00 2261,99 -78,08 1,59 -4,44 -7,73 0,00 0,00 -14,00
6 Facade N, package ventilation, air inlet Compressor Building Unit 1 0,00 0,00 74,02 2,50 78,00 3,00 2264,24 -78,09 3,93 -3,01 -0,74 0,00 0,00 3,08
22 Facade S, build. vent. air inlet Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 2285,43 -78,17 1,99 - -0,67 0,00 0,00 -21,28
21 Facade S, door Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 2282,19 -78,16 1,66 - -4,06 0,00 0,00 -32,16
7 Facade S, small door Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 2260,67 -78,08 1,63 -4,48 -7,77 0,00 0,00 -17,67
18 Facade W, build. vent. air inlet I Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 2273,05 -78,12 1,98 - -0,56 0,00 0,00 -15,85
19 Facade W, build. vent. air inlet II Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 2284,44 -78,17 1,99 - -0,57 0,00 0,00 -18,40
15 Facade W, door 1 Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 2270,32 -78,11 1,64 - -3,75 0,00 0,00 -24,89
16 Facade W, door 2 Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 2287,63 -78,18 1,66 - -3,43 0,00 0,00 -29,05
17 Facade W, package ventilation outlet Compressor Building Unit 1 0,00 0,00 78,00 1,00 78,00 3,00 2279,87 -78,15 3,89 - -0,29 0,00 0,00 -3,88
2 Facade north Compressor Building Unit 1 94,00 48,00 42,00 282,61 66,51 3,00 2264,29 -78,09 -0,14 -1,21 -4,32 0,00 0,00 -14,25
20 Facade south Compressor Building Unit 1 94,00 48,00 42,00 304,43 66,84 3,00 2285,74 -78,17 0,03 - -1,12 0,00 0,00 -24,12
14 Facade west Compressor Building Unit 1 94,00 48,00 42,00 359,86 67,56 3,00 2278,49 -78,15 -0,06 - -1,64 0,00 0,00 -19,52
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.32 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
8 Roof Compressor Building Unit 1 94,00 45,00 45,41 352,54 70,88 0,00 2274,40 -78,13 -1,10 -3,60 -3,33 0,00 0,00 -15,29
29 air intake duct Compressor Building Unit 1 0,00 0,00 80,00 80,00 0,00 2259,23 -78,07 -0,04 -2,87 -2,41 2,51 0,00 -0,88
27 oil demister Compressor Building Unit 1 0,00 0,00 80,00 80,00 0,00 2278,04 -78,14 0,14 - -4,63 0,00 0,00 -12,67
9 roof, explosion panel Compressor Building Unit 1 94,00 16,00 74,24 100,10 94,24 0,00 2274,30 -78,13 -0,73 -3,54 -4,97 0,00 0,00 6,87
40 Building vent., exhaust 1 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 2249,24 -78,03 0,88 -4,10 -3,65 0,00 0,00 1,10
41 Building vent., exhaust 2 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 2244,62 -78,01 0,87 -4,12 -3,67 0,00 0,00 1,06
42 Building vent., exhaust 3 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 2244,45 -78,01 0,88 -4,14 -3,69 0,00 0,00 1,04
43 Building vent., exhaust 4 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 2239,44 -77,99 0,86 -4,12 -3,67 0,00 0,00 1,07
35 Facade N, GT air intake Compressor Building Unit 3 0,00 0,00 74,26 3,75 80,00 3,00 2234,09 -77,97 0,40 0,00 -2,11 0,00 0,00 3,32
34 Facade N, build. vent. air intlet Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 2236,69 -77,98 1,97 0,00 -3,07 0,00 0,00 -7,01
33 Facade N, large door Compressor Building Unit 3 94,00 30,00 59,73 15,57 71,66 3,00 2232,00 -77,97 1,59 0,00 -8,36 0,00 0,00 -10,08
36 Facade N, package ventilation, air inlet Compressor Building Unit 3 0,00 0,00 74,02 2,50 78,00 3,00 2234,10 -77,97 3,93 0,00 -0,94 0,00 0,00 6,01
52 Facade S, build. vent. air inlet Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 2255,58 -78,06 1,99 - -0,58 0,00 0,00 -18,67
51 Facade S, door Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 2252,57 -78,05 1,66 - -3,67 0,00 0,00 -30,59
37 Facade S, small door Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 2230,77 -77,96 1,63 0,00 -8,35 0,00 0,00 -13,66
48 Facade W, build. vent. air inlet I Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 2242,72 -78,01 1,97 -8,61 -0,68 0,00 0,00 -13,26
49 Facade W, build. vent. air inlet II Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 2254,26 -78,05 1,98 - -0,58 0,00 0,00 -15,48
45 Facade W, door 1 Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 2239,95 -78,00 1,63 - -5,27 0,00 0,00 -21,52
46 Facade W, door 2 Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 2257,50 -78,06 1,66 - -3,62 0,00 0,00 -26,07
47 Facade W, package ventilation outlet Compressor Building Unit 3 0,00 0,00 78,00 1,00 78,00 3,00 2249,64 -78,03 3,89 -7,76 -0,31 0,00 0,00 -1,22
32 Facade north Compressor Building Unit 3 94,00 48,00 42,00 282,61 66,51 3,00 2234,16 -77,97 -0,16 0,00 -3,82 0,00 0,00 -12,44
50 Facade south Compressor Building Unit 3 94,00 48,00 42,00 304,43 66,84 3,00 2255,89 -78,06 0,02 - -1,19 0,00 0,00 -23,29
44 Facade west Compressor Building Unit 3 94,00 48,00 42,00 359,86 67,56 3,00 2248,21 -78,03 -0,07 -9,81 -1,69 0,00 0,00 -19,04
38 Roof Compressor Building Unit 3 94,00 45,00 45,41 352,54 70,88 0,00 2244,72 -78,02 -1,11 -3,05 -3,43 0,00 0,00 -14,73
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.33 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
57 air intake duct Compressor Building Unit 3 0,00 0,00 80,00 80,00 0,00 2229,47 -77,96 -0,05 0,00 -2,06 2,55 0,00 2,48
56 oil demister Compressor Building Unit 3 0,00 0,00 80,00 80,00 0,00 2247,70 -78,03 0,13 -9,74 -4,64 0,00 0,00 -12,28
39 roof, explosion panel Compressor Building Unit 3 94,00 16,00 74,24 100,10 94,24 0,00 2244,33 -78,01 -0,74 -3,54 -4,92 0,01 0,00 7,04
69 Building vent., exhaust 1 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 2241,66 -78,00 0,88 -4,10 -3,65 0,00 0,00 1,13
70 Building vent., exhaust 2 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 2237,02 -77,99 0,87 -4,12 -3,67 0,00 0,00 1,09
71 Building vent., exhaust 3 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 2237,45 -77,99 0,88 -4,10 -3,65 0,00 0,00 1,15
72 Building vent., exhaust 4 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 2231,88 -77,97 0,86 -4,12 -3,67 0,00 0,00 1,10
80 Facade E, build. vent. air inlet I Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 2239,25 -77,99 1,98 0,00 -3,08 0,00 0,00 -7,02
81 Facade E, build. vent. air inlet II Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 2227,64 -77,95 1,97 0,00 -3,07 0,00 0,00 -6,98
78 Facade E, door 1 Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 2242,04 -78,00 1,66 0,00 -8,38 0,00 0,00 -13,72
77 Facade E, door 2 Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 2224,39 -77,94 1,63 0,00 -8,34 0,00 0,00 -13,62
79 Facade E, package ventilation, air ou Compressor Building Unit 4 0,00 0,00 78,00 1,00 78,00 3,00 2232,27 -77,97 3,88 0,00 -0,94 0,00 0,00 5,98
64 Facade N, GT air intake Compressor Building Unit 4 0,00 0,00 74,26 3,75 80,00 3,00 2226,13 -77,94 0,40 0,00 -2,10 0,00 0,00 3,35
63 Facade N, build. vent. air inlet Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 2223,80 -77,93 1,97 0,00 -3,07 0,00 0,00 -6,96
62 Facade N, large door Compressor Building Unit 4 94,00 30,00 59,73 15,57 71,66 3,00 2228,54 -77,95 1,59 0,00 -8,35 0,00 0,00 -10,06
65 Facade N, package ventilation, air i Compressor Building Unit 4 0,00 0,00 74,02 2,50 78,00 3,00 2226,14 -77,94 3,93 0,00 -0,94 0,00 0,00 6,05
66 Facade N, small door Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 2229,55 -77,96 1,63 0,00 -8,35 0,00 0,00 -13,66
75 Facade S, build. vent. air inlet Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 2248,06 -78,03 1,99 - -0,58 0,00 0,00 -18,66
74 Facade S, door Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 2250,86 -78,04 1,66 - -3,16 0,00 0,00 -28,53
76 Facade east Compressor Building Unit 4 94,00 48,00 42,00 359,86 67,56 3,00 2233,59 -77,97 -0,06 0,00 -3,84 0,00 0,00 -11,31
61 Facade north Compressor Building Unit 4 94,00 48,00 42,00 282,61 66,51 3,00 2225,93 -77,94 -0,16 0,00 -3,81 0,00 0,00 -12,40
73 Facade south Compressor Building Unit 4 94,00 48,00 42,00 304,43 66,84 3,00 2247,74 -78,03 0,04 - -1,19 0,00 0,00 -22,77
67 Roof Compressor Building Unit 4 94,00 45,00 45,41 352,54 70,88 0,00 2237,17 -77,99 -1,11 -3,05 -3,42 0,00 0,00 -14,68
86 air intake duct Compressor Building Unit 4 0,00 0,00 80,00 80,00 0,00 2222,11 -77,93 -0,05 0,00 -2,05 2,54 0,00 2,51
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.34 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
85 oil demister Compressor Building Unit 4 0,00 0,00 80,00 80,00 0,00 2231,90 -77,97 0,13 0,00 -8,39 2,54 0,00 -3,69
68 roof, explosion panel Compressor Building Unit 4 94,00 16,00 74,24 100,10 94,24 0,00 2236,78 -77,98 -0,74 -3,54 -4,91 0,00 0,00 7,07
98 Building vent., exhaust 1 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 2221,83 -77,93 0,87 -4,10 -3,64 0,00 0,00 1,21
99 Building vent., exhaust 2 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 2217,15 -77,91 0,86 -4,12 -3,66 0,00 0,00 1,18
100 Building vent., exhaust 3 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 2217,40 -77,91 0,87 -4,10 -3,64 0,00 0,00 1,22
101 Building vent., exhaust 4 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 2212,33 -77,89 0,86 -4,12 -3,66 0,00 0,00 1,18
93 Facade N, GT air intake Compressor Building Unit 5 0,00 0,00 74,26 3,75 80,00 3,00 2206,68 -77,87 0,40 0,00 -2,09 0,00 0,00 3,44
92 Facade N, build. vent. air intlet Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 2209,09 -77,88 1,97 0,00 -3,06 0,00 0,00 -6,90
91 Facade N, large door Compressor Building Unit 5 94,00 30,00 59,73 15,57 71,66 3,00 2204,76 -77,86 1,58 0,00 -8,29 0,00 0,00 -9,91
94 Facade N, package ventilation, air inlet Compressor Building Unit 5 0,00 0,00 74,02 2,50 78,00 3,00 2206,69 -77,87 3,92 0,00 -0,93 0,00 0,00 6,12
110 Facade S, build. vent. air inlet Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 2228,45 -77,95 1,99 - -0,57 0,00 0,00 -18,63
109 Facade S, door Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 2225,67 -77,94 1,66 - -3,70 0,00 0,00 -25,23
95 Facade S, small door Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 2203,62 -77,85 1,63 0,00 -8,29 0,00 0,00 -13,50
106 Facade W, build. vent. air inlet I Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 2215,11 -77,90 1,97 -8,38 -0,70 0,00 0,00 -12,94
107 Facade W, build. vent. air inlet II Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 2226,79 -77,95 1,98 - -0,58 0,00 0,00 -15,04
103 Facade W, door 1 Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 2212,31 -77,89 1,63 - -5,40 0,00 0,00 -21,11
104 Facade W, door 2 Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 2230,07 -77,96 1,66 - -3,68 0,00 0,00 -25,58
105 Facade W, package ventilation outlet Compressor Building Unit 5 0,00 0,00 78,00 1,00 78,00 3,00 2222,11 -77,93 3,88 -7,48 -0,31 0,00 0,00 -0,83
90 Facade north Compressor Building Unit 5 94,00 48,00 42,00 282,61 66,51 3,00 2206,75 -77,87 -0,16 0,00 -3,79 0,00 0,00 -12,31
108 Facade south Compressor Building Unit 5 94,00 48,00 42,00 304,43 66,84 3,00 2228,73 -77,95 0,01 - -1,25 0,00 0,00 -22,78
102 Facade west Compressor Building Unit 5 94,00 48,00 42,00 359,86 67,56 3,00 2220,67 -77,92 -0,08 -9,53 -1,73 0,00 0,00 -18,70
96 Roof Compressor Building Unit 5 94,00 45,00 45,41 352,54 70,88 0,00 2217,47 -77,91 -1,11 -3,04 -3,40 0,00 0,00 -14,59
115 air intake duct Compressor Building Unit 5 0,00 0,00 80,00 80,00 0,00 2201,87 -77,85 -0,06 0,00 -2,04 2,54 0,00 2,59
114 oil demister Compressor Building Unit 5 0,00 0,00 80,00 80,00 0,00 2219,41 -77,92 0,12 -9,49 -4,65 0,00 0,00 -11,94
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.35 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
97 roof, explosion panel Compressor Building Unit 5 94,00 16,00 74,24 100,10 94,24 0,00 2217,07 -77,91 -0,74 -3,54 -4,88 0,00 0,00 7,18
340 Facade E Electrical Building 87,43 37,00 39,28 92,30 58,93 3,00 2159,02 -77,68 1,10 0,00 -9,44 0,00 0,00 -24,08
341 Facade E, sec. 1 Electrical Building 87,43 37,00 39,28 127,16 60,33 3,00 2155,15 -77,66 0,86 0,00 -9,48 0,00 0,00 -22,95
342 Facade E, sec. 2 Electrical Building 87,43 37,00 39,28 8,11 48,37 3,00 2160,00 -77,68 0,84 0,00 -9,50 0,00 0,00 -34,97
343 Facade E, sec. 3 Electrical Building 87,43 37,00 39,28 58,38 56,94 3,00 2161,81 -77,69 0,82 0,00 -9,51 0,00 0,00 -26,44
344 Facade E, sec. 4 Electrical Building 87,43 37,00 39,28 2,59 43,42 3,00 2164,76 -77,70 0,89 -5,87 -8,79 0,00 0,00 -45,04
345 Facade E, sec. 5 Electrical Building 87,43 37,00 39,28 67,56 57,58 3,00 2168,07 -77,71 0,83 0,00 -9,53 0,00 0,00 -25,83
334 Facade S, sec. 1 Electrical Building 87,43 37,00 39,28 72,39 57,88 3,00 2187,67 -77,79 1,45 - -7,79 0,00 0,00 -38,56
336 Facade S, sec. 2 Electrical Building 87,43 37,00 39,28 5,65 46,80 3,00 2183,83 -77,78 1,45 - -8,33 0,00 0,00 -46,95
337 Facade S, sec. 3 Electrical Building 87,43 37,00 39,28 48,15 56,11 3,00 2181,07 -77,77 1,44 - -7,80 0,00 0,00 -40,25
338 Facade S, sec. 4 Electrical Building 87,43 37,00 39,28 6,42 47,36 3,00 2179,52 -77,76 1,45 - -7,82 0,00 0,00 -48,87
339 Facade S, sec. 5 Electrical Building 87,43 37,00 39,28 131,91 60,48 3,00 2174,31 -77,74 1,45 - -7,73 0,00 0,00 -35,53
346 Facade W Electrical Building 87,43 37,00 39,28 97,41 59,17 3,00 2181,05 -77,77 1,37 - -7,72 0,00 0,00 -35,26
335 Roof Electrical Building 87,43 37,00 39,28 1181,57 70,01 0,00 2170,61 -77,72 0,82 -4,65 -9,11 0,00 0,00 -20,66
117 Filter I Filter 0,00 0,00 69,83 5,21 77,00 0,00 2403,63 -78,61 0,92 -3,41 -5,59 0,00 0,00 -9,69
118 Filter II Filter 0,00 0,00 69,82 5,22 77,00 0,00 2406,96 -78,62 0,92 -3,88 -5,89 0,00 0,00 -10,47
119 Filter IV Filter 0,00 0,00 69,80 5,25 77,00 0,00 2413,81 -78,65 0,92 -3,09 -5,63 0,00 0,00 -9,45
120 Filter V Filter 0,00 0,00 69,80 5,25 77,00 0,00 2417,21 -78,66 0,92 -0,02 -6,76 0,00 0,00 -7,52
122 Explosion relief panel Fuel Gas Skid I 87,00 16,00 66,62 30,00 81,39 0,00 2404,59 -78,61 0,47 -3,41 -5,75 0,00 0,00 -5,91
125 Fuel Gas Skid, facade E Fuel Gas Skid I 87,00 37,00 45,32 126,06 66,33 3,00 2403,35 -78,61 0,86 -4,05 -6,36 0,00 0,00 -18,83
126 Fuel Gas Skid, facade E, door Fuel Gas Skid I 87,00 30,00 57,56 4,84 64,41 3,00 2398,03 -78,59 1,70 -4,59 -9,26 0,00 0,00 -23,33
123 Fuel Gas Skid, facade S Fuel Gas Skid I 87,00 37,00 45,32 61,38 63,20 3,00 2411,62 -78,64 0,86 -6,52 -6,28 0,00 0,00 -24,38
124 Fuel Gas Skid, facade S, door Fuel Gas Skid I 87,00 37,00 45,32 7,04 53,80 3,00 2411,59 -78,64 0,99 - -5,07 0,00 0,00 -46,33
128 Fuel Gas Skid, facade W Fuel Gas Skid I 87,00 37,00 45,32 130,90 66,49 3,00 2406,33 -78,62 0,87 -6,25 -6,27 0,00 0,00 -20,79
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.36 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
121 Fuel Gas Skid, roof Fuel Gas Skid I 87,00 37,00 45,32 93,97 65,05 0,00 2404,62 -78,61 0,86 -3,59 -6,32 0,00 0,00 -22,62
127 Ventilation, intake Fuel Gas Skid I 0,00 0,00 68,00 68,00 6,01 2400,83 -78,60 -4,75 0,06 -5,60 0,00 0,00 -14,87
129 Ventilation, outlet Fuel Gas Skid I 0,00 0,00 68,00 68,00 6,01 2411,01 -78,64 -4,75 - -5,62 0,00 0,00 -29,02
131 Explosion relief panel Fuel Gas Skid II 87,00 16,00 66,62 30,00 81,39 0,00 2390,61 -78,56 0,46 -2,53 -5,81 0,00 0,00 -5,06
132 Fuel Gas Skid, facade E Fuel Gas Skid II 87,00 37,00 45,32 126,06 66,33 3,00 2388,52 -78,55 0,85 -3,78 -6,31 0,00 0,00 -18,47
133 Fuel Gas Skid, facade E, door Fuel Gas Skid II 87,00 37,00 45,32 4,84 52,17 3,00 2393,09 -78,57 0,97 -4,36 -6,38 0,00 0,00 -33,17
135 Fuel Gas Skid, facade N Fuel Gas Skid II 87,00 37,00 45,32 63,58 63,35 3,00 2383,67 -78,54 0,83 -2,51 -6,46 0,00 0,00 -20,32
136 Fuel Gas Skid, facade N, door Fuel Gas Skid II 87,00 37,00 45,32 4,84 52,17 3,00 2383,72 -78,54 0,95 -2,93 -6,34 0,00 0,00 -31,68
137 Fuel Gas Skid, facade W Fuel Gas Skid II 87,00 37,00 45,32 130,90 66,49 3,00 2392,37 -78,57 0,85 -4,58 -6,51 0,00 0,00 -19,32
130 Fuel Gas Skid, roof Fuel Gas Skid II 87,00 37,00 45,32 93,97 65,05 0,00 2390,64 -78,56 0,84 -2,49 -6,44 0,00 0,00 -21,61
134 Ventilation, intake Fuel Gas Skid II 0,00 0,00 68,00 68,00 6,01 2384,27 -78,54 -4,75 0,39 -5,56 0,00 0,00 -14,45
138 Ventilation, outlet Fuel Gas Skid II 0,00 0,00 68,00 68,00 6,01 2397,04 -78,59 -4,75 - -5,59 0,00 0,00 -28,46
296 Meter Run I Metering 0,00 0,00 72,70 39,44 88,66 0,00 2403,64 -78,61 2,12 -3,74 - 0,00 0,00 -2,55
297 Meter Run II Metering 0,00 0,00 72,70 39,45 88,66 0,00 2404,81 -78,61 2,12 -4,11 - 0,00 0,00 -2,96
298 Meter Run IV Metering 0,00 0,00 72,70 39,50 88,66 0,00 2407,18 -78,62 2,12 -4,48 - 0,00 0,00 -3,43
299 Meter Run V Metering 0,00 0,00 72,70 39,48 88,66 0,00 2408,38 -78,63 2,12 -4,53 - 0,00 0,00 -3,53
143 Header discharge side Piping 0,00 0,00 80,00 136,93 101,37 0,00 2300,58 -78,23 1,36 -6,65 -7,85 0,15 0,00 10,15
233 Header discharge side Piping 0,00 0,00 80,00 89,78 99,53 0,00 2263,72 -78,09 1,36 -1,20 -8,52 0,43 0,00 13,51
234 Header suction side Piping 0,00 0,00 78,00 93,78 97,72 0,00 2266,40 -78,10 1,36 -1,06 -8,53 0,18 0,00 11,56
144 Header suction side Piping 0,00 0,00 78,00 108,68 98,36 0,00 2299,25 -78,22 1,36 -6,37 -7,83 0,13 0,00 7,43
300 Facade E Power Generation Gas I 97,00 37,00 58,49 36,27 74,09 3,00 2304,96 -78,25 0,40 -3,06 -4,54 0,00 0,00 -8,36
302 Facade N Power Generation Gas I 97,00 37,00 58,49 58,24 76,15 3,00 2304,15 -78,24 0,39 -1,94 -4,73 0,00 0,00 -5,38
305 Facade S Power Generation Gas I 97,00 37,00 58,49 53,44 75,77 3,00 2311,34 -78,27 0,40 - -3,04 0,00 0,00 -16,40
306 Facade S, door Power Generation Gas I 97,00 30,00 64,01 4,84 70,86 3,00 2312,03 -78,27 1,03 - -2,06 0,00 0,00 -23,24
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.37 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
303 Facade W Power Generation Gas I 97,00 37,00 58,49 36,05 74,06 3,00 2310,63 -78,27 0,40 - -2,75 0,00 0,00 -19,16
308 Power Generation Gas I, Exhaust Stack Power Generation Gas I 0,00 0,00 90,00 90,00 0,00 2304,61 -78,24 0,14 -2,22 -2,09 0,00 0,00 7,58
301 Roof Power Generation Gas I 97,00 37,00 58,49 104,04 78,67 0,00 2307,77 -78,26 0,31 -1,57 -4,84 0,00 0,00 -5,70
304 Room ventilation, intake Power Generation Gas I 0,00 0,00 76,00 76,00 6,01 2311,53 -78,27 -4,75 - -5,39 0,00 0,00 -21,56
307 Room ventilation, outlet Power Generation Gas I 0,00 0,00 76,00 76,00 6,01 2310,46 -78,27 -4,75 - -5,39 0,00 0,00 -21,14
313 Facade E Power Generation Gas II 97,00 37,00 58,49 36,40 74,11 3,00 2286,93 -78,18 0,37 0,00 -4,97 0,00 0,00 -5,67
314 Facade N Power Generation Gas II 97,00 37,00 58,49 53,35 75,77 3,00 2286,21 -78,17 0,35 -4,21 -4,35 0,00 0,00 -7,62
315 Facade N, door Power Generation Gas II 97,00 30,00 64,01 4,84 70,86 3,00 2285,53 -78,17 1,00 -5,42 -4,11 0,00 0,00 -12,84
312 Facade S Power Generation Gas II 97,00 37,00 63,49 58,05 81,13 3,00 2293,41 -78,20 0,37 - -2,72 4,25 0,00 -6,83
309 Facade W Power Generation Gas II 97,00 37,00 58,49 36,20 74,08 3,00 2292,62 -78,20 0,36 - -2,50 0,00 0,00 -18,95
317 Power Generation Gas II, Exhaust Stack Power Generation Gas II 0,00 0,00 90,00 90,00 0,00 2287,00 -78,18 0,00 0,00 -2,85 0,00 0,00 8,97
311 Roof Power Generation Gas II 97,00 37,00 58,49 104,19 78,67 0,00 2289,76 -78,19 0,14 -3,39 -4,45 0,00 0,00 -7,21
310 Room ventilation, intake Power Generation Gas II 0,00 0,00 76,00 76,00 6,01 2293,50 -78,20 -4,75 - -5,35 0,00 0,00 -21,55
316 Room ventilation, outlet Power Generation Gas II 0,00 0,00 76,00 76,00 6,01 2287,11 -78,18 -4,75 -0,58 -5,33 0,00 0,00 -6,84
159 Distrib. pipe 1 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2354,72 -78,43 2,22 -3,00 - 0,00 0,00 -18,32
146 Distrib. pipe 1 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2334,45 -78,36 2,14 -8,25 - 0,00 0,00 -18,23
160 Distrib. pipe 2 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2354,34 -78,43 2,22 -2,22 - 0,00 0,00 -19,24
148 Distrib. pipe 2 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2334,09 -78,35 2,14 -8,12 - 0,00 0,00 -17,99
161 Distrib. pipe 3 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2353,98 -78,43 2,22 -1,80 - 0,00 0,00 -19,69
149 Distrib. pipe 3 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2333,66 -78,35 2,14 -7,94 - 0,00 0,00 -17,74
162 Distrib. pipe 4 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2353,50 -78,43 2,22 -1,80 - 0,00 0,00 -19,65
150 Distrib. pipe 4 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2333,29 -78,35 2,14 -7,56 - 0,00 0,00 -17,34
163 Distrib. pipe 5 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2353,12 -78,42 2,22 -1,78 - 0,00 0,00 -19,57
151 Distrib. pipe 5 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2332,92 -78,35 2,14 -6,95 - 0,00 0,00 -16,89
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.38 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
164 Distrib. pipe 6 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2352,76 -78,42 2,22 -1,75 - 0,00 0,00 -19,49
152 Distrib. pipe 6 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2332,50 -78,35 2,14 -5,85 - 0,00 0,00 -16,40
165 Distrib. pipe 7 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2352,32 -78,42 2,22 -1,70 - 0,00 0,00 -19,37
153 Distrib. pipe 7 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2332,04 -78,35 2,14 -2,58 - 0,00 0,00 -15,63
166 Distrib. pipe 8 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2351,94 -78,42 2,22 -1,64 - 0,00 0,00 -19,25
154 Distrib. pipe 8 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2331,67 -78,35 2,14 -2,30 - 0,00 0,00 -15,41
167 Distrib. pipe 9 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2351,58 -78,42 2,22 -1,54 - 0,00 0,00 -19,13
155 Distrib. pipe 9 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2331,25 -78,34 2,14 -2,72 - 0,00 0,00 -14,89
168 Distrib. pipe 10 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2351,11 -78,42 2,22 -1,36 - 0,00 0,00 -18,98
156 Distrib. pipe 10 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2330,82 -78,34 2,14 -2,50 - 0,00 0,00 -14,80
169 Distrib. pipe 11 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2350,74 -78,42 2,22 -1,18 - 0,00 0,00 -18,88
157 Distrib. pipe 11 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2330,30 -78,34 2,14 -2,73 - 0,00 0,00 -15,10
170 Distrib. pipe 12 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 2350,37 -78,41 2,22 -0,73 - 0,00 0,00 -18,44
158 Distrib. pipe 12 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 2329,88 -78,34 2,14 -1,96 - 0,00 0,00 -15,64
295 Header discharge side, Start Up Cooler Start Up Cooler 0,00 0,00 80,00 94,83 99,77 0,00 2266,62 -78,10 1,36 -1,44 -8,43 0,18 0,00 13,34
229 Header discharge side, Start Up Cooler Start Up Cooler 0,00 0,00 80,00 164,54 102,16 0,00 2310,01 -78,26 1,37 -7,41 -7,36 0,00 0,00 10,50
140 Start Up Cooler Start Up Cooler 0,00 0,00 66,17 191,91 89,00 0,00 2343,43 -78,39 1,06 -1,18 -8,35 0,00 0,00 2,14
142 Start Up Cooler, gas flow noise Start Up Cooler 0,00 0,00 70,16 192,32 93,00 0,00 2343,44 -78,39 1,06 -1,18 -8,35 0,00 0,00 6,14
147 Distrib. pipe 1 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2348,71 -78,41 2,24 0,00 - 0,00 0,00 -17,67
293 Distrib. pipe 1 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2331,12 -78,34 2,23 -5,26 - 0,00 0,00 -21,55
200 Distrib. pipe 2 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2348,34 -78,41 2,24 0,00 - 0,00 0,00 -17,54
294 Distrib. pipe 2 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2330,77 -78,34 2,23 -5,27 - 0,00 0,00 -21,57
201 Distrib. pipe 3 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2347,97 -78,41 2,24 0,00 - 0,00 0,00 -17,53
265 Distrib. pipe 3 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2330,41 -78,34 2,23 -5,28 - 0,00 0,00 -21,58
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.39 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
202 Distrib. pipe 4 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2347,53 -78,40 2,24 0,00 - 0,00 0,00 -17,53
266 Distrib. pipe 4 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2329,99 -78,34 2,23 -5,28 - 0,00 0,00 -21,58
267 Distrib. pipe 5 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2329,64 -78,34 2,23 -5,27 - 0,00 0,00 -21,57
203 Distrib. pipe 5 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2347,16 -78,40 2,24 0,00 - 0,00 0,00 -17,53
268 Distrib. pipe 6 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2329,28 -78,34 2,23 -5,27 - 0,00 0,00 -21,55
204 Distrib. pipe 6 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2346,80 -78,40 2,24 0,00 - 0,00 0,00 -17,52
269 Distrib. pipe 7 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2328,84 -78,33 2,23 -5,26 - 0,00 0,00 -21,50
205 Distrib. pipe 7 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2346,33 -78,40 2,24 0,00 - 0,00 0,00 -17,52
206 Distrib. pipe 8 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2345,96 -78,40 2,24 0,00 - 0,00 0,00 -17,52
270 Distrib. pipe 8 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2328,49 -78,33 2,23 -5,24 - 0,00 0,00 -21,45
207 Distrib. pipe 9 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2345,59 -78,40 2,24 0,00 - 0,00 0,00 -17,51
271 Distrib. pipe 9 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2328,13 -78,33 2,23 -5,22 - 0,00 0,00 -21,38
272 Distrib. pipe 10 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2327,72 -78,33 2,23 -5,18 - 0,00 0,00 -21,26
208 Distrib. pipe 10 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2345,15 -78,40 2,24 0,00 - 0,00 0,00 -17,51
209 Distrib. pipe 11 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2344,79 -78,39 2,24 0,00 - 0,00 0,00 -17,51
273 Distrib. pipe 11 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2327,37 -78,33 2,23 -5,13 - 0,00 0,00 -21,13
210 Distrib. pipe 12 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2344,42 -78,39 2,24 -1,28 - 0,00 0,00 -17,72
274 Distrib. pipe 12 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2327,01 -78,33 2,23 -5,05 - 0,00 0,00 -20,97
211 Distrib. pipe 13 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2343,99 -78,39 2,24 -1,74 - 0,00 0,00 -18,94
275 Distrib. pipe 13 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2326,61 -78,33 2,23 -4,90 - 0,00 0,00 -20,69
212 Distrib. pipe 14 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2343,63 -78,39 2,24 -2,39 - 0,00 0,00 -19,26
276 Distrib. pipe 14 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2326,26 -78,33 2,23 -4,70 - 0,00 0,00 -20,39
213 Distrib. pipe 15 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2343,26 -78,39 2,24 -3,21 - 0,00 0,00 -19,57
277 Distrib. pipe 15 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2325,90 -78,32 2,23 -4,35 - 0,00 0,00 -20,02
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.40 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
278 Distrib. pipe 16 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2325,49 -78,32 2,23 -3,54 - 0,00 0,00 -19,50
214 Distrib. pipe 16 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2342,83 -78,39 2,24 -3,91 - 0,00 0,00 -20,01
215 Distrib. pipe 17 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2342,46 -78,39 2,24 -4,26 - 0,00 0,00 -20,34
279 Distrib. pipe 17 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2325,14 -78,32 2,23 -2,51 - 0,00 0,00 -19,13
216 Distrib. pipe 18 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2342,10 -78,38 2,24 -4,49 - 0,00 0,00 -20,62
280 Distrib. pipe 18 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2324,79 -78,32 2,23 -0,18 - 0,00 0,00 -17,52
217 Distrib. pipe 19 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2341,63 -78,38 2,24 -4,69 - 0,00 0,00 -20,90
281 Distrib. pipe 19 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2324,35 -78,32 2,23 0,00 - 0,00 0,00 -17,35
282 Distrib. pipe 20 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2324,00 -78,32 2,23 0,00 - 0,00 0,00 -17,35
218 Distrib. pipe 20 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2341,27 -78,38 2,24 -4,82 - 0,00 0,00 -21,08
283 Distrib. pipe 21 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2323,65 -78,32 2,23 -1,33 - 0,00 0,00 -17,58
219 Distrib. pipe 21 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2340,90 -78,38 2,24 -4,94 - 0,00 0,00 -21,23
220 Distrib. pipe 22 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2340,47 -78,38 2,24 -5,09 - 0,00 0,00 -21,38
284 Distrib. pipe 22 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2323,24 -78,31 2,23 -0,15 - 0,00 0,00 -17,38
285 Distrib. pipe 23 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2322,90 -78,31 2,23 0,00 - 0,00 0,00 -17,34
221 Distrib. pipe 23 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2340,11 -78,38 2,24 -5,19 - 0,00 0,00 -21,47
222 Distrib. pipe 24 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2339,75 -78,38 2,24 -5,21 - 0,00 0,00 -21,53
286 Distrib. pipe 24 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2322,55 -78,31 2,23 0,00 - 0,00 0,00 -17,34
287 Distrib. pipe 25 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2322,10 -78,31 2,23 0,00 - 0,00 0,00 -17,34
223 Distrib. pipe 25 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2339,28 -78,37 2,24 -5,23 - 0,00 0,00 -21,58
224 Distrib. pipe 26 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2338,91 -78,37 2,24 -5,24 - 0,00 0,00 -21,61
288 Distrib. pipe 26 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2321,75 -78,31 2,23 0,00 - 0,00 0,00 -17,33
289 Distrib. pipe 27 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2321,40 -78,31 2,23 0,00 - 0,00 0,00 -17,33
225 Distrib. pipe 27 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2338,55 -78,37 2,24 -5,25 - 0,00 0,00 -21,63
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.41 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
290 Distrib. pipe 28 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2320,99 -78,31 2,23 0,00 - 0,00 0,00 -17,33
226 Distrib. pipe 28 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2338,12 -78,37 2,24 -5,25 - 0,00 0,00 -21,64
227 Distrib. pipe 29 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2337,76 -78,37 2,24 -5,26 - 0,00 0,00 -21,63
291 Distrib. pipe 29 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2320,65 -78,30 2,23 0,00 - 0,00 0,00 -17,32
292 Distrib. pipe 30 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2320,31 -78,30 2,23 0,00 - 0,00 0,00 -17,32
228 Distrib. pipe 30 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 2337,40 -78,37 2,24 -5,25 - 0,00 0,00 -21,62
139 Gas Cooler 1/2 Transportation Gas Cooler 0,00 0,00 66,05 495,71 93,00 0,00 2334,93 -78,36 1,05 -0,49 -7,23 0,00 0,00 7,98
145 Gas Cooler 1/2, distrib. pipe 1 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2332,09 -78,35 2,19 -2,04 - 0,00 0,00 -17,09
171 Gas Cooler 1/2, distrib. pipe 2 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2331,71 -78,35 2,19 -2,01 - 0,00 0,00 -16,99
172 Gas Cooler 1/2, distrib. pipe 3 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2331,34 -78,34 2,19 -1,97 - 0,00 0,00 -16,88
173 Gas Cooler 1/2, distrib. pipe 4 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2330,88 -78,34 2,19 -1,90 - 0,00 0,00 -16,73
174 Gas Cooler 1/2, distrib. pipe 5 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2330,51 -78,34 2,19 -1,81 - 0,00 0,00 -16,58
175 Gas Cooler 1/2, distrib. pipe 6 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2330,14 -78,34 2,19 -1,66 - 0,00 0,00 -16,42
176 Gas Cooler 1/2, distrib. pipe 7 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2329,68 -78,34 2,19 -1,39 - 0,00 0,00 -16,25
177 Gas Cooler 1/2, distrib. pipe 8 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2329,31 -78,34 2,19 -1,18 - 0,00 0,00 -15,95
178 Gas Cooler 1/2, distrib. pipe 9 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2328,94 -78,34 2,19 0,00 - 0,00 0,00 -14,32
179 Gas Cooler 1/2, distrib. pipe 10 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2328,50 -78,33 2,19 0,00 - 0,00 0,00 -14,32
180 Gas Cooler 1/2, distrib. pipe 11 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2328,13 -78,33 2,19 0,00 - 0,00 0,00 -14,32
181 Gas Cooler 1/2, distrib. pipe 12 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2327,76 -78,33 2,19 0,00 - 0,00 0,00 -14,31
182 Gas Cooler 1/2, distrib. pipe 13 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2327,29 -78,33 2,19 0,00 - 0,00 0,00 -14,31
183 Gas Cooler 1/2, distrib. pipe 14 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2326,92 -78,33 2,19 0,00 - 0,00 0,00 -14,31
184 Gas Cooler 1/2, distrib. pipe 15 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2326,55 -78,33 2,19 0,00 - 0,00 0,00 -14,30
185 Gas Cooler 1/2, distrib. pipe 16 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2326,10 -78,32 2,19 0,00 - 0,00 0,00 -14,30
186 Gas Cooler 1/2, distrib. pipe 17 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2325,73 -78,32 2,19 0,00 - 0,00 0,00 -14,30
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.42 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
187 Gas Cooler 1/2, distrib. pipe 18 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2325,36 -78,32 2,19 0,00 - 0,00 0,00 -14,29
188 Gas Cooler 1/2, distrib. pipe 19 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2324,95 -78,32 2,19 -2,02 - 0,00 0,00 -14,76
189 Gas Cooler 1/2, distrib. pipe 20 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2324,58 -78,32 2,19 -2,04 - 0,00 0,00 -14,77
190 Gas Cooler 1/2, distrib. pipe 21 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2324,22 -78,32 2,19 -2,20 - 0,00 0,00 -15,97
191 Gas Cooler 1/2, distrib. pipe 22 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2323,76 -78,32 2,19 -3,41 - 0,00 0,00 -16,36
192 Gas Cooler 1/2, distrib. pipe 23 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2323,40 -78,31 2,19 -4,19 - 0,00 0,00 -16,78
193 Gas Cooler 1/2, distrib. pipe 24 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2323,03 -78,31 2,19 -4,70 - 0,00 0,00 -17,19
194 Gas Cooler 1/2, distrib. pipe 25 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2322,59 -78,31 2,19 -5,13 - 0,00 0,00 -17,61
195 Gas Cooler 1/2, distrib. pipe 26 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2322,22 -78,31 2,19 -5,40 - 0,00 0,00 -17,90
196 Gas Cooler 1/2, distrib. pipe 27 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2321,86 -78,31 2,19 -5,65 - 0,00 0,00 -18,14
197 Gas Cooler 1/2, distrib. pipe 28 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2321,41 -78,31 2,19 -5,95 - 0,00 0,00 -18,39
198 Gas Cooler 1/2, distrib. pipe 29 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2321,04 -78,31 2,19 -6,20 - 0,00 0,00 -18,58
199 Gas Cooler 1/2, distrib. pipe 30 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2320,68 -78,30 2,19 -6,46 - 0,00 0,00 -18,76
141 Gas Cooler 1/2, gas flow noise Transportation Gas Cooler 0,00 0,00 66,05 495,71 93,00 0,00 2334,93 -78,36 1,05 -0,49 -7,23 0,00 0,00 7,98
231 Gas Cooler 3/4 Transportation Gas Cooler 0,00 0,00 66,04 496,15 93,00 0,00 2317,55 -78,29 1,05 -3,57 -6,23 0,00 0,00 5,94
235 Gas Cooler 3/4, distrib. pipe 1 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2314,37 -78,28 2,19 -6,77 - 0,00 0,00 -19,29
236 Gas Cooler 3/4, distrib. pipe 2 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2314,01 -78,28 2,19 -6,77 - 0,00 0,00 -19,29
237 Gas Cooler 3/4, distrib. pipe 3 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2313,65 -78,28 2,19 -6,77 - 0,00 0,00 -19,29
238 Gas Cooler 3/4, distrib. pipe 4 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2313,21 -78,28 2,19 -6,77 - 0,00 0,00 -19,28
239 Gas Cooler 3/4, distrib. pipe 5 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2312,85 -78,28 2,19 -6,51 - 0,00 0,00 -18,72
240 Gas Cooler 3/4, distrib. pipe 6 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2312,50 -78,27 2,19 -6,63 - 0,00 0,00 -18,83
241 Gas Cooler 3/4, distrib. pipe 7 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2312,06 -78,27 2,19 -6,65 - 0,00 0,00 -18,90
242 Gas Cooler 3/4, distrib. pipe 8 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2311,71 -78,27 2,19 -6,67 - 0,00 0,00 -18,93
243 Gas Cooler 3/4, distrib. pipe 9 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2311,35 -78,27 2,19 -6,68 - 0,00 0,00 -18,96
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.43 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
244 Gas Cooler 3/4, distrib. pipe 10 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2310,94 -78,27 2,19 -6,69 - 0,00 0,00 -18,97
245 Gas Cooler 3/4, distrib. pipe 11 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2310,58 -78,27 2,19 -6,69 - 0,00 0,00 -18,97
246 Gas Cooler 3/4, distrib. pipe 12 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2310,23 -78,27 2,19 -6,69 - 0,00 0,00 -18,96
247 Gas Cooler 3/4, distrib. pipe 13 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2309,78 -78,26 2,19 -6,69 - 0,00 0,00 -18,94
248 Gas Cooler 3/4, distrib. pipe 14 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2309,42 -78,26 2,19 -6,68 - 0,00 0,00 -18,91
249 Gas Cooler 3/4, distrib. pipe 15 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2309,07 -78,26 2,19 -6,66 - 0,00 0,00 -18,86
250 Gas Cooler 3/4, distrib. pipe 16 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2308,64 -78,26 2,19 -6,63 - 0,00 0,00 -18,78
251 Gas Cooler 3/4, distrib. pipe 17 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2308,28 -78,26 2,19 -6,60 - 0,00 0,00 -18,69
252 Gas Cooler 3/4, distrib. pipe 18 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2307,93 -78,26 2,19 -6,54 - 0,00 0,00 -18,56
253 Gas Cooler 3/4, distrib. pipe 19 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2307,54 -78,26 2,19 -6,43 - 0,00 0,00 -18,34
254 Gas Cooler 3/4, distrib. pipe 20 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2307,19 -78,25 2,19 -6,30 - 0,00 0,00 -18,10
255 Gas Cooler 3/4, distrib. pipe 21 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2306,84 -78,25 2,19 -6,08 - 0,00 0,00 -17,77
256 Gas Cooler 3/4, distrib. pipe 22 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2306,41 -78,25 2,19 -5,58 - 0,00 0,00 -17,25
257 Gas Cooler 3/4, distrib. pipe 23 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2306,06 -78,25 2,19 -4,78 - 0,00 0,00 -16,71
258 Gas Cooler 3/4, distrib. pipe 24 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2305,71 -78,25 2,19 -3,46 - 0,00 0,00 -16,19
259 Gas Cooler 3/4, distrib. pipe 25 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2305,28 -78,25 2,19 0,00 - 0,00 0,00 -14,15
260 Gas Cooler 3/4, distrib. pipe 26 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2304,93 -78,25 2,19 0,00 - 0,00 0,00 -14,14
261 Gas Cooler 3/4, distrib. pipe 27 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2304,59 -78,24 2,19 -0,26 - 0,00 0,00 -14,21
262 Gas Cooler 3/4, distrib. pipe 28 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2304,16 -78,24 2,19 -2,13 - 0,00 0,00 -14,62
263 Gas Cooler 3/4, distrib. pipe 29 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2303,81 -78,24 2,19 -1,64 - 0,00 0,00 -14,60
264 Gas Cooler 3/4, distrib. pipe 30 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 2303,46 -78,24 2,19 0,00 - 0,00 0,00 -14,13
232 Gas Cooler 3/4, gas flow noise Transportation Gas Cooler 0,00 0,00 66,04 496,10 93,00 0,00 2317,55 -78,29 1,05 -3,57 -6,23 0,00 0,00 5,94
230 Header Discharge side Transportation Gas Cooler 0,00 0,00 78,00 90,45 97,56 0,00 2332,70 -78,35 1,39 -3,36 -8,26 0,00 0,00 8,99
28 Control valve (enclosed) Unit 1 0,00 0,00 87,00 87,00 3,01 2291,01 -78,19 -4,75 - -9,31 0,00 0,00 -22,09
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.44 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
23 Exhaust Stack Opening Unit 1 0,00 0,00 84,97 2,01 88,00 0,00 2283,71 -78,16 1,33 -4,35 -3,31 0,00 0,00 3,50
24 Exhaust duct outsde compressor Unit 1 0,00 0,00 76,40 12,10 87,23 0,00 2282,10 -78,16 2,93 -9,15 -0,34 0,00 0,00 2,50
1 Oil Cooler Unit 1 0,00 0,00 78,11 24,50 92,00 0,00 2275,92 -78,14 1,08 -4,35 -5,43 0,00 0,00 5,15
25 Piping suction side Unit 1 0,00 0,00 78,00 34,38 93,36 0,00 2302,09 -78,23 1,35 - -5,52 0,00 0,00 -8,70
26 Piping, discharge side Unit 1 0,00 0,00 80,00 30,25 94,81 0,00 2293,27 -78,20 1,34 - -6,12 0,00 0,00 -9,70
58 Control valve (eingehaust) Unit 3 0,00 0,00 87,00 87,00 3,01 2261,63 -78,08 -4,75 - -9,19 1,85 0,00 -19,65
31 Exhaust Stack Opening Unit 3 0,00 0,00 84,97 2,01 88,00 0,00 2253,75 -78,05 1,32 -4,35 -3,30 0,00 0,00 3,63
53 Exhaust duct outsde compressor Unit 3 0,00 0,00 79,40 6,06 87,23 0,00 2252,24 -78,04 2,93 -7,58 -0,63 0,00 0,00 3,89
30 Oil Cooler Unit 3 0,00 0,00 78,11 24,50 92,00 0,00 2245,85 -78,02 1,07 0,00 -5,95 0,00 0,00 9,10
54 Piping suction side Unit 3 0,00 0,00 78,00 34,38 93,36 0,00 2272,79 -78,12 1,35 - -5,50 0,00 0,00 -7,62
55 Piping, discharge side Unit 3 0,00 0,00 80,00 30,25 94,81 0,00 2264,27 -78,09 1,34 - -5,95 0,00 0,00 -4,91
87 Control valve (eingehaust) Unit 4 0,00 0,00 87,00 87,00 3,01 2254,38 -78,05 -4,75 - -9,16 0,00 0,00 -19,93
60 Exhaust Stack Opening Unit 4 0,00 0,00 84,97 2,01 88,00 0,00 2233,84 -77,97 1,32 -4,35 -3,29 0,00 0,00 3,71
82 Exhaust duct outsde compressor Unit 4 0,00 0,00 79,58 5,82 87,23 0,00 2235,23 -77,98 2,92 0,00 -3,93 0,29 0,00 8,53
59 Oil Cooler Unit 4 0,00 0,00 78,11 24,50 92,00 0,00 2226,22 -77,94 1,07 0,00 -5,92 0,00 0,00 9,21
83 Piping suction side Unit 4 0,00 0,00 78,00 34,38 93,36 0,00 2265,57 -78,10 1,35 - -5,89 0,00 0,00 -3,94
84 Piping, discharge side Unit 4 0,00 0,00 80,00 30,25 94,81 0,00 2257,12 -78,06 1,34 -2,94 -8,00 0,00 0,00 7,14
116 Control valve (eingehaust) Unit 5 0,00 0,00 87,00 87,00 3,01 2234,42 -77,98 -4,75 - -9,08 0,00 0,00 -19,76
89 Exhaust Stack Opening Unit 5 0,00 0,00 84,97 2,01 88,00 0,00 2225,87 -77,94 1,32 -4,35 -3,28 0,00 0,00 3,74
111 Exhaust duct outsde compressor Unit 5 0,00 0,00 79,44 6,01 87,23 0,00 2224,50 -77,94 2,92 -7,28 -0,73 0,00 0,00 4,20
88 Oil Cooler Unit 5 0,00 0,00 78,11 24,50 92,00 0,00 2217,91 -77,91 1,07 0,00 -5,91 0,00 0,00 9,25
112 Piping suction side Unit 5 0,00 0,00 78,00 34,38 93,36 0,00 2245,64 -78,02 1,34 - -5,87 0,00 0,00 -3,88
113 Piping, discharge side Unit 5 0,00 0,00 80,00 30,25 94,81 0,00 2237,42 -77,99 1,34 0,00 -8,56 0,00 0,00 9,60
330 Air compressor I, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 2210,99 -77,88 -4,75 - -5,16 0,00 0,00 -29,44
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.45 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
331 Air compressor II, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 2210,13 -77,88 -4,75 - -5,15 0,00 0,00 -29,50
332 Air compressor III, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 2209,26 -77,88 -4,75 - -5,15 0,00 0,00 -29,52
320 Air compressor room, ventilation Utility Building 0,00 0,00 68,00 68,00 3,01 2206,30 -77,87 -4,70 -0,07 -5,15 0,00 0,00 -16,77
354 Air condition unit I Utility Building 0,00 0,00 87,00 87,00 0,00 2205,46 -77,86 -0,78 -8,58 -4,14 0,00 0,00 -4,36
353 Air condition unit II Utility Building 0,00 0,00 87,00 87,00 0,00 2204,43 -77,86 -0,79 -7,39 -4,36 0,00 0,00 -3,41
333 Boiler room, ventilation intake Utility Building 0,00 0,00 72,00 72,00 6,01 2194,00 -77,82 -4,75 - -5,12 0,00 0,00 -24,72
326 Boiler room, ventilation outlet Utility Building 0,00 0,00 72,00 72,00 6,01 2198,45 -77,83 -4,74 0,00 -5,13 0,00 0,00 -9,69
321 Boiler, stack opening I Utility Building 0,00 0,00 78,00 78,00 3,01 2190,33 -77,80 -4,70 -0,07 -5,11 0,00 0,00 -6,67
323 Boiler, stack opening III Utility Building 0,00 0,00 78,00 78,00 3,01 2184,88 -77,78 -4,70 -0,07 -5,10 0,00 0,00 -6,64
322 Boiler, stack opening Ii Utility Building 0,00 0,00 78,00 78,00 3,01 2187,60 -77,79 -4,70 -0,07 -5,10 0,00 0,00 -6,65
318 Facade E Utility Building 87,43 37,00 37,28 117,45 57,98 3,00 2187,19 -77,79 1,04 -1,54 -9,24 0,00 0,00 -26,55
324 Facade N Utility Building 87,43 37,00 37,28 390,90 63,20 3,00 2190,86 -77,80 0,85 0,00 -9,45 0,00 0,00 -20,20
325 Facade N, doors Utility Building 87,43 30,00 51,96 22,00 65,38 3,00 2191,94 -77,81 2,06 0,00 - 0,00 0,00 -25,80
328 Facade S Utility Building 87,43 37,00 37,28 392,52 63,22 3,00 2202,90 -77,85 1,02 - -7,94 0,00 0,00 -35,25
329 Facade S, doors Utility Building 87,43 30,00 51,96 22,00 65,38 3,00 2202,00 -77,85 2,14 - - 0,00 0,00 -44,30
327 Facade W Utility Building 87,43 37,00 37,28 115,70 57,92 3,00 2206,86 -77,87 0,97 - -7,84 0,00 0,00 -37,30
319 Roof Utility Building 87,43 37,00 37,28 595,39 65,03 0,00 2196,79 -77,83 0,64 -4,62 -9,14 0,00 0,00 -25,92
351 Air condition unit I Workshop/Stores Building 0,00 0,00 87,00 87,00 0,00 2265,31 -78,09 -0,14 - -3,48 0,00 0,00 -9,11
352 Air condition unit II Workshop/Stores Building 0,00 0,00 87,00 87,00 0,00 2263,91 -78,09 -0,14 - -3,52 0,00 0,00 -8,63
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.46 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
Name 4 Station Fence West Ln = 60,0 dB(A)
347 Air condition unit I Administration Building 0,00 0,00 87,00 87,00 0,00 157,23 -54,92 3,00 - -0,29 0,00 0,00 23,60
348 Air condition unit II Administration Building 0,00 0,00 87,00 87,00 0,00 155,07 -54,80 3,00 - -0,28 1,99 0,00 25,34
349 Air condition unit III Administration Building 0,00 0,00 87,00 87,00 0,00 147,83 -54,39 3,00 0,00 -0,38 2,60 0,00 37,83
350 Air condition unit IV Administration Building 0,00 0,00 87,00 87,00 0,00 150,84 -54,56 3,00 0,00 -0,39 2,59 0,00 37,64
10 Building vent., exhaust 1 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 129,75 -53,25 3,00 -6,16 -1,03 1,39 0,00 29,94
11 Building vent., exhaust 2 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 131,65 -53,38 3,00 - -0,17 3,78 0,00 26,35
12 Building vent., exhaust 3 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 141,42 -54,00 3,00 -7,34 -0,55 2,09 0,00 29,21
13 Building vent., exhaust 4 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 143,23 -54,11 3,00 -7,60 -0,59 2,22 0,00 28,92
5 Facade N, GT air intake Compressor Building Unit 1 0,00 0,00 74,26 3,75 80,00 3,00 139,89 -53,91 3,00 - -0,11 0,17 0,00 21,01
4 Facade N, build. vent. air intlet Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 133,84 -53,52 3,92 -8,65 -0,19 0,00 0,00 13,62
3 Facade N, large door Compressor Building Unit 1 94,00 30,00 59,73 15,57 71,66 3,00 144,84 -54,21 3,34 - -0,48 0,47 0,00 6,72
6 Facade N, package ventilation, air inlet Compressor Building Unit 1 0,00 0,00 74,02 2,50 78,00 3,00 139,88 -53,91 3,17 -9,16 -0,05 0,20 0,00 21,25
22 Facade S, build. vent. air inlet Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 131,71 -53,38 3,88 0,00 -1,00 0,00 0,00 21,56
21 Facade S, door Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 139,40 -53,88 3,99 0,00 -0,81 0,00 0,00 20,32
7 Facade S, small door Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 147,81 -54,39 4,10 - -0,49 0,00 0,00 2,65
18 Facade W, build. vent. air inlet I Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 129,23 -53,22 3,84 0,00 -0,99 0,00 0,00 21,70
19 Facade W, build. vent. air inlet II Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 124,37 -52,89 3,76 0,00 -0,96 0,00 0,00 21,98
15 Facade W, door 1 Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 130,54 -53,31 3,85 0,00 -0,76 0,00 0,00 20,80
16 Facade W, door 2 Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 123,21 -52,80 3,72 0,00 -0,72 0,00 0,00 21,21
17 Facade W, package ventilation outlet Compressor Building Unit 1 0,00 0,00 78,00 1,00 78,00 3,00 126,19 -53,01 3,00 0,00 -0,35 0,02 0,00 30,65
2 Facade north Compressor Building Unit 1 94,00 48,00 42,00 282,61 66,51 3,00 139,99 -53,91 3,08 - -0,19 0,00 0,00 7,47
20 Facade south Compressor Building Unit 1 94,00 48,00 42,00 304,43 66,84 3,00 131,69 -53,38 3,07 0,00 -0,30 0,00 0,00 19,22
14 Facade west Compressor Building Unit 1 94,00 48,00 42,00 359,86 67,56 3,00 127,03 -53,07 3,07 -0,18 -0,29 0,00 0,00 20,09
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.47 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
8 Roof Compressor Building Unit 1 94,00 45,00 45,41 352,54 70,88 0,00 135,96 -53,66 3,00 -5,41 -0,26 0,00 0,00 14,55
29 air intake duct Compressor Building Unit 1 0,00 0,00 80,00 80,00 0,00 142,86 -54,09 3,00 0,00 -0,22 0,00 0,00 28,69
27 oil demister Compressor Building Unit 1 0,00 0,00 80,00 80,00 0,00 126,79 -53,05 3,00 0,00 -0,85 0,05 0,00 29,14
9 roof, explosion panel Compressor Building Unit 1 94,00 16,00 74,24 100,10 94,24 0,00 136,53 -53,70 3,00 -6,19 -0,35 1,72 0,00 38,73
40 Building vent., exhaust 1 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 201,27 -57,07 3,00 - -0,21 0,00 0,00 21,66
41 Building vent., exhaust 2 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 202,50 -57,12 3,00 - -0,19 0,00 0,00 20,12
42 Building vent., exhaust 3 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 213,42 -57,58 3,00 -5,76 -1,43 0,00 0,00 24,23
43 Building vent., exhaust 4 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 214,60 -57,62 3,00 - -0,24 0,00 0,00 17,06
35 Facade N, GT air intake Compressor Building Unit 3 0,00 0,00 74,26 3,75 80,00 3,00 210,04 -57,44 3,54 - -0,17 3,06 0,00 12,65
34 Facade N, build. vent. air intlet Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 203,59 -57,17 4,63 - -0,29 0,00 0,00 2,50
33 Facade N, large door Compressor Building Unit 3 94,00 30,00 59,73 15,57 71,66 3,00 215,29 -57,65 4,21 - -0,90 0,00 0,00 -2,44
36 Facade N, package ventilation, air inlet Compressor Building Unit 3 0,00 0,00 74,02 2,50 78,00 3,00 210,03 -57,44 4,11 - -0,11 1,70 0,00 12,69
52 Facade S, build. vent. air inlet Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 204,76 -57,22 4,64 0,00 -1,36 0,00 0,00 18,13
51 Facade S, door Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 212,62 -57,54 4,68 0,00 -1,19 0,00 0,00 16,97
37 Facade S, small door Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 218,42 -57,78 4,72 - -0,90 0,00 0,00 -5,65
48 Facade W, build. vent. air inlet I Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 199,67 -57,00 4,60 - -0,19 0,00 0,00 8,85
49 Facade W, build. vent. air inlet II Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 196,53 -56,86 4,58 0,00 -1,32 0,00 0,00 18,46
45 Facade W, door 1 Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 200,53 -57,04 4,60 - -0,62 0,00 0,00 1,36
46 Facade W, door 2 Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 195,78 -56,83 4,57 0,00 -1,10 0,00 0,00 17,66
47 Facade W, package ventilation outlet Compressor Building Unit 3 0,00 0,00 78,00 1,00 78,00 3,00 197,70 -56,91 3,50 -5,98 -0,11 0,19 0,00 21,68
32 Facade north Compressor Building Unit 3 94,00 48,00 42,00 282,61 66,51 3,00 209,61 -57,42 3,20 - -0,26 0,00 0,00 -4,48
50 Facade south Compressor Building Unit 3 94,00 48,00 42,00 304,43 66,84 3,00 203,67 -57,17 3,11 0,00 -0,46 0,00 0,00 15,31
44 Facade west Compressor Building Unit 3 94,00 48,00 42,00 359,86 67,56 3,00 198,22 -56,94 3,22 -3,04 -0,43 0,00 0,00 13,38
38 Roof Compressor Building Unit 3 94,00 45,00 45,41 352,54 70,88 0,00 207,51 -57,33 3,00 -7,20 -0,39 0,00 0,00 8,96
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.48 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
57 air intake duct Compressor Building Unit 3 0,00 0,00 80,00 80,00 0,00 212,17 -57,53 3,00 - -0,15 1,77 0,00 16,19
56 oil demister Compressor Building Unit 3 0,00 0,00 80,00 80,00 0,00 197,75 -56,91 3,00 - -0,61 0,62 0,00 15,70
39 roof, explosion panel Compressor Building Unit 3 94,00 16,00 74,24 100,10 94,24 0,00 208,23 -57,36 3,00 - -0,34 2,61 0,00 25,88
69 Building vent., exhaust 1 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 220,66 -57,87 3,00 -6,16 -1,36 0,00 0,00 23,61
70 Building vent., exhaust 2 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 221,78 -57,91 3,00 -9,92 -0,22 0,00 0,00 20,95
71 Building vent., exhaust 3 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 232,76 -58,33 3,00 -6,28 -1,21 1,36 0,00 24,54
72 Building vent., exhaust 4 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 234,04 -58,38 3,00 -6,05 -1,17 0,00 0,00 23,39
80 Facade E, build. vent. air inlet I Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 235,15 -58,42 4,81 - -0,28 0,00 0,00 2,29
81 Facade E, build. vent. air inlet II Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 237,78 -58,52 4,83 - -0,41 0,00 0,00 -0,74
78 Facade E, door 1 Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 234,61 -58,40 4,81 - -0,76 0,00 0,00 -1,38
77 Facade E, door 2 Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 238,62 -58,55 4,83 - -0,95 0,00 0,00 -5,78
79 Facade E, package ventilation, air ou Compressor Building Unit 4 0,00 0,00 78,00 1,00 78,00 3,00 236,65 -58,47 3,91 - -0,10 0,00 0,00 11,30
64 Facade N, GT air intake Compressor Building Unit 4 0,00 0,00 74,26 3,75 80,00 3,00 230,14 -58,23 3,75 - -0,19 3,25 0,00 11,93
63 Facade N, build. vent. air inlet Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 236,17 -58,46 4,82 - -0,38 0,00 0,00 -0,43
62 Facade N, large door Compressor Building Unit 4 94,00 30,00 59,73 15,57 71,66 3,00 223,96 -58,00 4,28 - -0,95 0,00 0,00 -2,99
65 Facade N, package ventilation, air i Compressor Building Unit 4 0,00 0,00 74,02 2,50 78,00 3,00 230,13 -58,23 4,28 - -0,12 1,82 0,00 11,80
66 Facade N, small door Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 221,43 -57,90 4,73 - -0,94 0,00 0,00 -6,08
75 Facade S, build. vent. air inlet Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 224,40 -58,01 4,76 0,00 -1,44 0,00 0,00 17,37
74 Facade S, door Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 217,01 -57,72 4,71 0,00 -1,21 0,00 0,00 16,80
76 Facade east Compressor Building Unit 4 94,00 48,00 42,00 359,86 67,56 3,00 236,49 -58,47 3,25 - -0,29 0,00 0,00 -2,03
61 Facade north Compressor Building Unit 4 94,00 48,00 42,00 282,61 66,51 3,00 230,42 -58,24 3,24 - -0,29 0,00 0,00 -5,49
73 Facade south Compressor Building Unit 4 94,00 48,00 42,00 304,43 66,84 3,00 224,95 -58,03 3,23 0,00 -0,51 0,00 0,00 14,53
67 Roof Compressor Building Unit 4 94,00 45,00 45,41 352,54 70,88 0,00 226,94 -58,11 3,00 -5,64 -0,44 0,00 0,00 9,69
86 air intake duct Compressor Building Unit 4 0,00 0,00 80,00 80,00 0,00 230,77 -58,26 3,00 - -0,16 1,96 0,00 11,87
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.49 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
85 oil demister Compressor Building Unit 4 0,00 0,00 80,00 80,00 0,00 237,81 -58,52 3,00 - -0,74 0,00 0,00 4,15
68 roof, explosion panel Compressor Building Unit 4 94,00 16,00 74,24 100,10 94,24 0,00 227,60 -58,14 3,00 -5,41 -0,61 1,44 0,00 34,52
98 Building vent., exhaust 1 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 274,52 -59,76 3,00 -6,03 -1,58 0,00 0,00 21,63
99 Building vent., exhaust 2 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 275,43 -59,79 3,00 -9,98 -0,36 0,00 0,00 18,87
100 Building vent., exhaust 3 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 286,84 -60,14 3,00 -5,76 -1,68 0,00 0,00 21,41
101 Building vent., exhaust 4 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 287,69 -60,17 3,00 -6,36 -1,34 0,00 0,00 21,12
93 Facade N, GT air intake Compressor Building Unit 5 0,00 0,00 74,26 3,75 80,00 3,00 282,54 -60,01 4,17 - -0,20 0,00 0,00 9,78
92 Facade N, build. vent. air intlet Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 275,96 -59,81 4,99 - -0,33 0,00 0,00 -0,03
91 Facade N, large door Compressor Building Unit 5 94,00 30,00 59,73 15,57 71,66 3,00 287,90 -60,18 4,66 - -1,02 0,00 0,00 -3,43
94 Facade N, package ventilation, air inlet Compressor Building Unit 5 0,00 0,00 74,02 2,50 78,00 3,00 282,54 -60,01 4,60 - -0,10 0,00 0,00 11,36
110 Facade S, build. vent. air inlet Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 278,74 -59,90 5,00 0,00 -1,64 0,00 0,00 15,53
109 Facade S, door Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 286,67 -60,14 5,02 0,00 -1,54 0,00 0,00 14,36
95 Facade S, small door Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 291,09 -60,27 5,04 - -1,03 0,00 0,00 -6,78
106 Facade W, build. vent. air inlet I Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 272,41 -59,70 4,98 - -0,21 0,00 0,00 5,82
107 Facade W, build. vent. air inlet II Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 270,12 -59,62 4,97 0,00 -1,61 0,00 0,00 15,80
103 Facade W, door 1 Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 273,04 -59,72 4,98 - -0,79 0,00 0,00 -1,76
104 Facade W, door 2 Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 269,58 -59,61 4,96 0,00 -1,46 0,00 0,00 14,91
105 Facade W, package ventilation outlet Compressor Building Unit 5 0,00 0,00 78,00 1,00 78,00 3,00 270,97 -59,65 4,17 -7,17 -0,09 0,04 0,00 18,30
90 Facade north Compressor Building Unit 5 94,00 48,00 42,00 282,61 66,51 3,00 282,17 -60,00 3,40 - -0,32 0,00 0,00 -5,19
108 Facade south Compressor Building Unit 5 94,00 48,00 42,00 304,43 66,84 3,00 277,72 -59,86 3,46 0,00 -0,62 0,00 0,00 12,81
102 Facade west Compressor Building Unit 5 94,00 48,00 42,00 359,86 67,56 3,00 271,38 -59,66 3,47 -4,78 -0,53 0,00 0,00 9,06
96 Roof Compressor Building Unit 5 94,00 45,00 45,41 352,54 70,88 0,00 280,89 -59,96 3,00 -5,12 -0,55 0,00 0,00 8,24
115 air intake duct Compressor Building Unit 5 0,00 0,00 80,00 80,00 0,00 284,39 -60,07 3,47 -9,92 -0,20 0,00 0,00 13,28
114 oil demister Compressor Building Unit 5 0,00 0,00 80,00 80,00 0,00 270,97 -59,65 3,00 - -0,74 2,29 0,00 13,38
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.50 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
97 roof, explosion panel Compressor Building Unit 5 94,00 16,00 74,24 100,10 94,24 0,00 281,37 -59,98 3,00 - -0,47 0,00 0,00 24,76
340 Facade E Electrical Building 87,43 37,00 39,28 92,30 58,93 3,00 250,99 -58,99 4,50 - -1,09 0,00 0,00 -13,17
341 Facade E, sec. 1 Electrical Building 87,43 37,00 39,28 127,16 60,33 3,00 244,66 -58,76 4,46 - -1,14 0,00 0,00 -13,66
342 Facade E, sec. 2 Electrical Building 87,43 37,00 39,28 8,11 48,37 3,00 235,11 -58,42 4,40 - -1,10 0,00 0,00 -25,19
343 Facade E, sec. 3 Electrical Building 87,43 37,00 39,28 58,38 56,94 3,00 230,71 -58,25 4,37 - -1,13 0,00 0,00 -17,60
344 Facade E, sec. 4 Electrical Building 87,43 37,00 39,28 2,59 43,42 3,00 225,68 -58,06 4,34 - -1,12 0,00 0,00 -31,42
345 Facade E, sec. 5 Electrical Building 87,43 37,00 39,28 67,56 57,58 3,00 220,00 -57,84 4,29 - -1,16 0,00 0,00 -17,76
334 Facade S, sec. 1 Electrical Building 87,43 37,00 39,28 72,39 57,88 3,00 205,77 -57,26 4,18 -6,01 -0,98 0,00 0,00 0,81
336 Facade S, sec. 2 Electrical Building 87,43 37,00 39,28 5,65 46,80 3,00 212,83 -57,55 4,24 - -0,91 0,00 0,00 -21,30
337 Facade S, sec. 3 Electrical Building 87,43 37,00 39,28 48,15 56,11 3,00 217,33 -57,73 4,27 -4,89 -1,05 0,00 0,00 -0,30
338 Facade S, sec. 4 Electrical Building 87,43 37,00 39,28 6,42 47,36 3,00 221,39 -57,90 4,30 -3,94 -1,09 0,00 0,00 -8,27
339 Facade S, sec. 5 Electrical Building 87,43 37,00 39,28 131,91 60,48 3,00 232,59 -58,32 4,37 -1,09 -1,36 0,00 0,00 7,08
346 Facade W Electrical Building 87,43 37,00 39,28 97,41 59,17 3,00 206,70 -57,30 4,18 - -0,96 0,00 0,00 -7,01
335 Roof Electrical Building 87,43 37,00 39,28 1181,57 70,01 0,00 227,36 -58,13 3,42 -5,87 -1,36 0,00 0,00 8,07
117 Filter I Filter 0,00 0,00 69,83 5,21 77,00 0,00 188,96 -56,52 3,00 -3,17 -0,93 0,00 0,00 19,38
118 Filter II Filter 0,00 0,00 69,82 5,22 77,00 0,00 181,53 -56,17 3,00 -3,69 -0,93 0,00 0,00 19,20
119 Filter IV Filter 0,00 0,00 69,80 5,25 77,00 0,00 167,05 -55,45 3,00 -3,78 -0,89 0,00 0,00 19,88
120 Filter V Filter 0,00 0,00 69,80 5,25 77,00 0,00 160,05 -55,08 3,00 -4,42 -0,96 0,00 0,00 19,54
122 Explosion relief panel Fuel Gas Skid I 87,00 16,00 66,62 30,00 81,39 0,00 97,59 -50,78 3,00 -4,74 -0,37 0,00 0,00 28,50
125 Fuel Gas Skid, facade E Fuel Gas Skid I 87,00 37,00 45,32 126,06 66,33 3,00 100,54 -51,04 3,09 -3,97 -0,31 0,00 0,00 17,11
126 Fuel Gas Skid, facade E, door Fuel Gas Skid I 87,00 30,00 57,56 4,84 64,41 3,00 96,79 -50,71 3,28 - -0,52 0,00 0,00 -1,67
123 Fuel Gas Skid, facade S Fuel Gas Skid I 87,00 37,00 45,32 61,38 63,20 3,00 103,07 -51,25 3,08 -3,35 -0,31 0,00 0,00 14,36
124 Fuel Gas Skid, facade S, door Fuel Gas Skid I 87,00 37,00 45,32 7,04 53,80 3,00 103,16 -51,26 3,39 - -0,24 0,00 0,00 -6,70
128 Fuel Gas Skid, facade W Fuel Gas Skid I 87,00 37,00 45,32 130,90 66,49 3,00 94,67 -50,52 3,00 0,00 -0,29 0,00 0,00 21,69
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.51 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
121 Fuel Gas Skid, roof Fuel Gas Skid I 87,00 37,00 45,32 93,97 65,05 0,00 97,41 -50,76 3,00 -4,74 -0,29 0,00 0,00 12,25
127 Ventilation, intake Fuel Gas Skid I 0,00 0,00 68,00 68,00 6,00 98,86 -50,89 -3,78 - -0,23 0,00 0,00 3,41
129 Ventilation, outlet Fuel Gas Skid I 0,00 0,00 68,00 68,00 6,00 98,53 -50,86 -3,77 0,00 -0,23 0,00 0,00 19,14
131 Explosion relief panel Fuel Gas Skid II 87,00 16,00 66,62 30,00 81,39 0,00 87,33 -49,82 3,00 -4,75 -0,34 0,00 0,00 29,49
132 Fuel Gas Skid, facade E Fuel Gas Skid II 87,00 37,00 45,32 126,06 66,33 3,00 90,43 -50,12 3,06 -3,64 -0,27 0,00 0,00 18,35
133 Fuel Gas Skid, facade E, door Fuel Gas Skid II 87,00 37,00 45,32 4,84 52,17 3,00 93,30 -50,39 3,26 - -0,21 0,00 0,00 -10,87
135 Fuel Gas Skid, facade N Fuel Gas Skid II 87,00 37,00 45,32 63,58 63,35 3,00 82,69 -49,34 3,01 0,00 -0,25 0,00 0,00 19,77
136 Fuel Gas Skid, facade N, door Fuel Gas Skid II 87,00 37,00 45,32 4,84 52,17 3,00 82,68 -49,34 3,00 0,00 -0,25 0,00 0,00 8,58
137 Fuel Gas Skid, facade W Fuel Gas Skid II 87,00 37,00 45,32 130,90 66,49 3,00 84,12 -49,49 3,00 0,00 -0,26 0,00 0,00 22,74
130 Fuel Gas Skid, roof Fuel Gas Skid II 87,00 37,00 45,32 93,97 65,05 0,00 87,15 -49,80 3,00 -4,70 -0,26 0,00 0,00 13,29
134 Ventilation, intake Fuel Gas Skid II 0,00 0,00 68,00 68,00 6,00 87,55 -49,84 -3,62 - -0,20 0,00 0,00 7,99
138 Ventilation, outlet Fuel Gas Skid II 0,00 0,00 68,00 68,00 6,00 87,50 -49,83 -3,62 0,00 -0,20 0,00 0,00 20,35
296 Meter Run I Metering 0,00 0,00 72,70 39,44 88,66 0,00 136,54 -53,70 3,07 -8,13 -0,71 0,01 0,00 29,20
297 Meter Run II Metering 0,00 0,00 72,70 39,45 88,66 0,00 134,15 -53,54 3,05 -8,81 -0,70 0,01 0,00 28,68
298 Meter Run IV Metering 0,00 0,00 72,70 39,50 88,66 0,00 129,44 -53,23 3,02 -9,94 -0,67 0,02 0,00 27,87
299 Meter Run V Metering 0,00 0,00 72,70 39,48 88,66 0,00 127,12 -53,08 3,00 - -0,65 0,01 0,00 27,54
143 Header discharge side Piping 0,00 0,00 80,00 136,93 101,37 0,00 140,59 -53,95 3,41 0,00 -0,85 0,51 0,00 50,48
233 Header discharge side Piping 0,00 0,00 80,00 89,78 99,53 0,00 247,13 -58,85 4,53 0,00 -1,37 0,32 0,00 44,16
234 Header suction side Piping 0,00 0,00 78,00 93,78 97,72 0,00 244,34 -58,75 4,51 0,00 -1,36 0,40 0,00 42,52
144 Header suction side Piping 0,00 0,00 78,00 108,68 98,36 0,00 149,46 -54,48 3,52 0,00 -0,90 0,42 0,00 46,93
300 Facade E Power Generation Gas I 97,00 37,00 58,49 36,27 74,09 3,00 76,78 -48,70 3,04 - -0,13 0,19 0,00 18,18
302 Facade N Power Generation Gas I 97,00 37,00 58,49 58,24 76,15 3,00 74,19 -48,40 3,03 - -0,13 4,56 0,00 25,62
305 Facade S Power Generation Gas I 97,00 37,00 58,49 53,44 75,77 3,00 68,88 -47,75 3,00 0,00 -0,16 0,00 0,00 33,86
306 Facade S, door Power Generation Gas I 97,00 30,00 64,01 4,84 70,86 3,00 68,04 -47,65 3,00 0,00 -0,39 0,00 0,00 28,82
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.52 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
303 Facade W Power Generation Gas I 97,00 37,00 58,49 36,05 74,06 3,00 66,71 -47,48 3,00 0,00 -0,16 0,00 0,00 32,43
308 Power Generation Gas I, Exhaust Stack Power Generation Gas I 0,00 0,00 90,00 90,00 0,00 77,57 -48,79 3,00 -0,47 -0,17 0,00 0,00 43,58
301 Roof Power Generation Gas I 97,00 37,00 58,49 104,04 78,67 0,00 71,58 -48,09 3,00 -4,74 -0,17 0,11 0,00 28,78
304 Room ventilation, intake Power Generation Gas I 0,00 0,00 76,00 76,00 6,00 66,10 -47,40 -3,50 0,00 -0,15 0,00 0,00 30,95
307 Room ventilation, outlet Power Generation Gas I 0,00 0,00 76,00 76,00 6,00 70,93 -48,01 -3,53 0,00 -0,17 0,00 0,00 30,30
313 Facade E Power Generation Gas II 97,00 37,00 58,49 36,40 74,11 3,00 90,01 -50,08 3,12 - -0,16 0,09 0,00 17,88
314 Facade N Power Generation Gas II 97,00 37,00 58,49 53,35 75,77 3,00 88,98 -49,98 3,10 - -0,15 0,00 0,00 18,37
315 Facade N, door Power Generation Gas II 97,00 30,00 64,01 4,84 70,86 3,00 89,88 -50,07 3,18 - -0,19 0,00 0,00 10,19
312 Facade S Power Generation Gas II 97,00 37,00 63,49 58,05 81,13 3,00 82,75 -49,35 3,00 0,00 -0,20 0,72 0,00 38,31
309 Facade W Power Generation Gas II 97,00 37,00 58,49 36,20 74,08 3,00 81,68 -49,23 3,00 0,00 -0,19 0,01 0,00 30,66
317 Power Generation Gas II, Exhaust Stack Power Generation Gas II 0,00 0,00 90,00 90,00 0,00 90,51 -50,13 3,00 -0,13 -0,18 0,02 0,00 42,58
311 Roof Power Generation Gas II 97,00 37,00 58,49 104,19 78,67 0,00 85,95 -49,68 3,00 -4,73 -0,20 0,62 0,00 27,69
310 Room ventilation, intake Power Generation Gas II 0,00 0,00 76,00 76,00 6,01 81,07 -49,17 -3,78 0,00 -0,19 0,01 0,00 28,88
316 Room ventilation, outlet Power Generation Gas II 0,00 0,00 76,00 76,00 6,01 87,65 -49,85 -3,83 - -0,20 0,37 0,00 14,03
159 Distrib. pipe 1 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 131,94 -53,40 3,20 0,00 -3,84 0,04 0,00 32,31
146 Distrib. pipe 1 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 127,37 -53,09 3,15 0,00 -3,76 2,52 0,00 39,06
160 Distrib. pipe 2 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 132,85 -53,46 3,20 0,00 -3,87 0,07 0,00 32,26
148 Distrib. pipe 2 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 128,33 -53,16 3,15 0,00 -3,78 2,52 0,00 38,97
161 Distrib. pipe 3 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 133,75 -53,52 3,21 0,00 -3,89 0,22 0,00 32,33
149 Distrib. pipe 3 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 129,29 -53,22 3,15 0,00 -3,81 2,54 0,00 38,90
162 Distrib. pipe 4 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 134,87 -53,59 3,21 0,00 -3,92 0,23 0,00 32,24
150 Distrib. pipe 4 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 130,38 -53,30 3,16 0,00 -3,84 2,55 0,00 38,82
163 Distrib. pipe 5 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 135,78 -53,65 3,22 0,00 -3,95 0,23 0,00 32,17
151 Distrib. pipe 5 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 131,34 -53,36 3,16 0,00 -3,87 2,57 0,00 38,75
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.53 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
164 Distrib. pipe 6 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 136,69 -53,71 3,22 0,00 -3,97 0,23 0,00 32,09
152 Distrib. pipe 6 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 132,30 -53,42 3,16 0,00 -3,89 2,59 0,00 38,68
165 Distrib. pipe 7 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 137,81 -53,78 3,23 0,00 -4,00 0,24 0,00 32,00
153 Distrib. pipe 7 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 133,43 -53,50 3,17 0,00 -3,92 2,60 0,00 38,60
166 Distrib. pipe 8 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 138,72 -53,84 3,23 0,00 -4,03 0,24 0,00 31,93
154 Distrib. pipe 8 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 134,38 -53,56 3,17 0,00 -3,95 2,62 0,00 38,53
167 Distrib. pipe 9 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 139,63 -53,89 3,24 0,00 -4,05 0,39 0,00 32,00
155 Distrib. pipe 9 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 135,35 -53,62 3,18 0,00 -3,98 2,64 0,00 38,46
168 Distrib. pipe 10 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 140,75 -53,96 3,24 0,00 -4,08 0,80 0,00 32,31
156 Distrib. pipe 10 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 136,48 -53,69 3,18 0,00 -4,01 2,32 0,00 38,05
169 Distrib. pipe 11 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 141,67 -54,02 3,24 0,00 -4,11 1,03 0,00 32,46
157 Distrib. pipe 11 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 137,43 -53,75 3,18 0,00 -4,03 2,16 0,00 37,80
170 Distrib. pipe 12 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 142,58 -54,07 3,25 0,00 -4,13 1,03 0,00 32,39
158 Distrib. pipe 12 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 138,40 -53,81 3,19 0,00 -4,06 2,11 0,00 37,66
295 Header discharge side, Start Up Cooler Start Up Cooler 0,00 0,00 80,00 94,83 99,77 0,00 244,81 -58,77 4,51 0,00 -1,36 0,42 0,00 44,57
229 Header discharge side, Start Up Cooler Start Up Cooler 0,00 0,00 80,00 164,54 102,16 0,00 136,68 -53,71 3,34 0,00 -0,83 0,60 0,00 51,56
140 Start Up Cooler Start Up Cooler 0,00 0,00 66,17 191,91 89,00 0,00 134,89 -53,59 3,00 0,00 -1,74 0,83 0,00 37,50
142 Start Up Cooler, gas flow noise Start Up Cooler 0,00 0,00 70,16 192,32 93,00 0,00 134,89 -53,59 3,00 0,00 -1,74 0,83 0,00 41,50
147 Distrib. pipe 1 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 143,30 -54,12 3,29 0,00 -4,15 1,01 0,00 31,63
293 Distrib. pipe 1 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 188,09 -56,48 3,53 0,00 -5,34 0,00 0,00 27,30
200 Distrib. pipe 2 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 144,22 -54,17 3,30 0,00 -4,18 1,13 0,00 31,67
294 Distrib. pipe 2 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 189,02 -56,52 3,53 0,00 -5,37 0,00 0,00 27,24
201 Distrib. pipe 3 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 145,14 -54,23 3,30 0,00 -4,20 1,86 0,00 32,33
265 Distrib. pipe 3 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 189,96 -56,57 3,54 0,00 -5,39 0,00 0,00 27,17
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.54 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
202 Distrib. pipe 4 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 146,27 -54,30 3,31 0,00 -4,23 2,19 0,00 32,57
266 Distrib. pipe 4 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 191,11 -56,62 3,55 0,00 -5,42 0,00 0,00 27,10
267 Distrib. pipe 5 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 192,04 -56,66 3,55 0,00 -5,45 0,00 0,00 27,03
203 Distrib. pipe 5 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 147,19 -54,35 3,31 0,00 -4,26 2,20 0,00 32,50
268 Distrib. pipe 6 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 192,98 -56,70 3,56 0,00 -5,47 0,00 0,00 26,97
204 Distrib. pipe 6 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 148,11 -54,40 3,32 0,00 -4,28 2,22 0,00 32,44
269 Distrib. pipe 7 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 194,10 -56,75 3,56 0,00 -5,50 0,00 0,00 26,90
205 Distrib. pipe 7 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 149,22 -54,47 3,32 0,00 -4,31 2,23 0,00 32,37
206 Distrib. pipe 8 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 150,14 -54,52 3,33 0,00 -4,34 2,24 0,00 32,30
270 Distrib. pipe 8 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 195,04 -56,79 3,57 0,00 -5,53 0,00 0,00 26,84
207 Distrib. pipe 9 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 151,06 -54,58 3,33 0,00 -4,36 2,25 0,00 32,24
271 Distrib. pipe 9 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 195,97 -56,84 3,57 0,00 -5,55 0,00 0,00 26,78
272 Distrib. pipe 10 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 197,12 -56,89 3,58 0,00 -5,58 0,00 0,00 26,70
208 Distrib. pipe 10 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 152,20 -54,64 3,34 0,00 -4,39 2,27 0,00 32,17
209 Distrib. pipe 11 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 153,12 -54,69 3,34 0,00 -4,42 2,28 0,00 32,10
273 Distrib. pipe 11 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 198,05 -56,93 3,58 0,00 -5,60 0,00 0,00 26,64
210 Distrib. pipe 12 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 154,04 -54,75 3,35 0,00 -4,44 2,29 0,00 32,04
274 Distrib. pipe 12 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 198,99 -56,97 3,59 0,00 -5,63 0,00 0,00 26,58
211 Distrib. pipe 13 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 155,18 -54,81 3,35 0,00 -4,47 2,27 0,00 31,94
275 Distrib. pipe 13 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 200,13 -57,02 3,59 0,00 -5,66 0,00 0,00 26,51
212 Distrib. pipe 14 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 156,10 -54,86 3,36 0,00 -4,50 1,60 0,00 31,20
276 Distrib. pipe 14 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 201,07 -57,06 3,60 0,00 -5,68 0,00 0,00 26,45
213 Distrib. pipe 15 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 157,02 -54,91 3,36 0,00 -4,52 1,61 0,00 31,13
277 Distrib. pipe 15 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 202,00 -57,10 3,60 0,00 -5,71 0,00 0,00 26,39
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.55 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
278 Distrib. pipe 16 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 203,15 -57,15 3,61 0,00 -5,74 0,00 0,00 26,32
214 Distrib. pipe 16 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 158,16 -54,97 3,37 0,00 -4,55 1,62 0,00 31,05
215 Distrib. pipe 17 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 159,09 -55,02 3,38 0,00 -4,58 1,62 0,00 30,99
279 Distrib. pipe 17 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 204,09 -57,19 3,61 0,00 -5,76 0,00 0,00 26,26
216 Distrib. pipe 18 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 160,01 -55,08 3,38 0,00 -4,60 1,54 0,00 30,84
280 Distrib. pipe 18 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 205,02 -57,23 3,62 0,00 -5,79 0,00 0,00 26,20
217 Distrib. pipe 19 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 161,13 -55,14 3,39 0,00 -4,63 1,55 0,00 30,76
281 Distrib. pipe 19 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 206,15 -57,28 3,63 0,00 -5,82 0,00 0,00 26,13
282 Distrib. pipe 20 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 207,08 -57,32 3,63 0,00 -5,84 0,00 0,00 26,07
218 Distrib. pipe 20 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 162,05 -55,19 3,39 0,00 -4,65 1,55 0,00 30,69
283 Distrib. pipe 21 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 208,02 -57,35 3,64 0,00 -5,86 0,00 0,00 26,01
219 Distrib. pipe 21 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 162,98 -55,23 3,40 0,00 -4,68 1,56 0,00 30,63
220 Distrib. pipe 22 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 164,12 -55,30 3,40 0,00 -4,71 1,64 0,00 30,63
284 Distrib. pipe 22 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 209,17 -57,40 3,64 0,00 -5,89 0,00 0,00 25,94
285 Distrib. pipe 23 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 210,11 -57,44 3,65 0,00 -5,92 0,00 0,00 25,88
221 Distrib. pipe 23 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 165,05 -55,34 3,41 0,00 -4,73 1,57 0,00 30,49
222 Distrib. pipe 24 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 165,97 -55,39 3,41 0,00 -4,76 1,58 0,00 30,43
286 Distrib. pipe 24 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 211,04 -57,48 3,65 0,00 -5,94 0,00 0,00 25,82
287 Distrib. pipe 25 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 212,18 -57,53 3,66 0,00 -5,97 0,00 0,00 25,75
223 Distrib. pipe 25 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 167,10 -55,45 3,42 0,00 -4,79 1,58 0,00 30,35
224 Distrib. pipe 26 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 168,02 -55,50 3,42 0,00 -4,81 1,59 0,00 30,29
288 Distrib. pipe 26 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 213,12 -57,56 3,66 0,00 -6,00 0,00 0,00 25,69
289 Distrib. pipe 27 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 214,05 -57,60 3,67 0,00 -6,02 0,00 0,00 25,64
225 Distrib. pipe 27 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 168,95 -55,55 3,43 0,00 -4,84 1,59 0,00 30,23
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.56 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
290 Distrib. pipe 28 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 215,21 -57,65 3,68 0,00 -6,05 0,00 0,00 25,57
226 Distrib. pipe 28 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 170,10 -55,61 3,43 0,00 -4,87 1,60 0,00 30,15
227 Distrib. pipe 29 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 171,02 -55,65 3,44 0,00 -4,89 1,61 0,00 30,09
291 Distrib. pipe 29 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 216,14 -57,69 3,68 0,00 -6,08 0,00 0,00 25,51
292 Distrib. pipe 30 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 217,08 -57,72 3,69 0,00 -6,10 0,00 0,00 25,45
228 Distrib. pipe 30 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 171,95 -55,70 3,44 0,00 -4,92 1,61 0,00 30,03
139 Gas Cooler 1/2 Transportation Gas Cooler 0,00 0,00 66,05 495,71 93,00 0,00 155,42 -54,82 3,00 0,00 -1,90 0,83 0,00 40,11
145 Gas Cooler 1/2, distrib. pipe 1 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 139,78 -53,90 3,26 0,00 -4,10 2,69 0,00 36,78
171 Gas Cooler 1/2, distrib. pipe 2 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 140,72 -53,96 3,26 0,00 -4,13 1,91 0,00 35,92
172 Gas Cooler 1/2, distrib. pipe 3 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 141,67 -54,02 3,27 0,00 -4,15 1,73 0,00 35,66
173 Gas Cooler 1/2, distrib. pipe 4 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 142,82 -54,09 3,28 0,00 -4,18 1,68 0,00 35,52
174 Gas Cooler 1/2, distrib. pipe 5 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 143,76 -54,14 3,28 0,00 -4,21 1,69 0,00 35,45
175 Gas Cooler 1/2, distrib. pipe 6 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 144,71 -54,20 3,29 0,00 -4,23 1,70 0,00 35,37
176 Gas Cooler 1/2, distrib. pipe 7 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 145,85 -54,27 3,29 0,00 -4,27 1,71 0,00 35,29
177 Gas Cooler 1/2, distrib. pipe 8 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 146,79 -54,33 3,30 0,00 -4,29 1,71 0,00 35,22
178 Gas Cooler 1/2, distrib. pipe 9 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 147,73 -54,38 3,30 0,00 -4,32 1,72 0,00 35,15
179 Gas Cooler 1/2, distrib. pipe 10 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 148,89 -54,45 3,31 0,00 -4,35 1,73 0,00 35,07
180 Gas Cooler 1/2, distrib. pipe 11 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 149,83 -54,50 3,31 0,00 -4,37 1,74 0,00 35,00
181 Gas Cooler 1/2, distrib. pipe 12 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 150,77 -54,56 3,32 0,00 -4,40 1,74 0,00 34,93
182 Gas Cooler 1/2, distrib. pipe 13 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 151,92 -54,62 3,32 0,00 -4,43 0,53 0,00 33,62
183 Gas Cooler 1/2, distrib. pipe 14 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 152,86 -54,68 3,33 0,00 -4,46 0,42 0,00 33,44
184 Gas Cooler 1/2, distrib. pipe 15 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 153,81 -54,73 3,33 0,00 -4,48 0,32 0,00 33,26
185 Gas Cooler 1/2, distrib. pipe 16 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 154,97 -54,80 3,34 0,00 -4,52 0,20 0,00 33,05
186 Gas Cooler 1/2, distrib. pipe 17 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 155,91 -54,85 3,34 0,00 -4,54 0,20 0,00 32,98
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.57 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
187 Gas Cooler 1/2, distrib. pipe 18 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 156,86 -54,90 3,34 0,00 -4,57 0,20 0,00 32,91
188 Gas Cooler 1/2, distrib. pipe 19 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 158,01 -54,97 3,35 0,00 -4,60 0,20 0,00 32,82
189 Gas Cooler 1/2, distrib. pipe 20 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 158,96 -55,02 3,35 0,00 -4,62 0,21 0,00 32,75
190 Gas Cooler 1/2, distrib. pipe 21 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 159,90 -55,07 3,36 0,00 -4,65 0,03 0,00 32,50
191 Gas Cooler 1/2, distrib. pipe 22 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 161,04 -55,13 3,37 0,00 -4,68 0,00 0,00 32,38
192 Gas Cooler 1/2, distrib. pipe 23 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 161,98 -55,18 3,37 0,00 -4,71 0,00 0,00 32,31
193 Gas Cooler 1/2, distrib. pipe 24 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 162,93 -55,23 3,38 0,00 -4,73 0,00 0,00 32,24
194 Gas Cooler 1/2, distrib. pipe 25 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 164,09 -55,29 3,38 0,00 -4,76 0,00 0,00 32,15
195 Gas Cooler 1/2, distrib. pipe 26 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 165,03 -55,34 3,39 0,00 -4,79 0,00 0,00 32,08
196 Gas Cooler 1/2, distrib. pipe 27 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 165,97 -55,39 3,39 0,00 -4,82 0,00 0,00 32,01
197 Gas Cooler 1/2, distrib. pipe 28 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 167,11 -55,45 3,40 0,00 -4,85 0,00 0,00 31,93
198 Gas Cooler 1/2, distrib. pipe 29 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 168,06 -55,50 3,40 0,00 -4,87 0,00 0,00 31,86
199 Gas Cooler 1/2, distrib. pipe 30 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 169,00 -55,55 3,41 0,00 -4,90 0,00 0,00 31,79
141 Gas Cooler 1/2, gas flow noise Transportation Gas Cooler 0,00 0,00 66,05 495,71 93,00 0,00 155,43 -54,82 3,00 0,00 -1,90 0,83 0,00 40,10
231 Gas Cooler 3/4 Transportation Gas Cooler 0,00 0,00 66,04 496,15 93,00 0,00 200,89 -57,05 3,00 0,00 -2,20 0,00 0,00 36,74
235 Gas Cooler 3/4, distrib. pipe 1 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 185,44 -56,36 3,49 0,00 -5,34 0,00 0,00 30,62
236 Gas Cooler 3/4, distrib. pipe 2 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 186,39 -56,40 3,49 0,00 -5,37 0,00 0,00 30,56
237 Gas Cooler 3/4, distrib. pipe 3 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 187,33 -56,44 3,50 0,00 -5,39 0,00 0,00 30,49
238 Gas Cooler 3/4, distrib. pipe 4 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 188,49 -56,50 3,51 0,00 -5,42 0,00 0,00 30,41
239 Gas Cooler 3/4, distrib. pipe 5 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 189,44 -56,54 3,51 0,00 -5,45 0,00 0,00 30,35
240 Gas Cooler 3/4, distrib. pipe 6 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 190,38 -56,58 3,51 0,00 -5,47 0,00 0,00 30,28
241 Gas Cooler 3/4, distrib. pipe 7 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 191,53 -56,64 3,52 0,00 -5,50 0,00 0,00 30,21
242 Gas Cooler 3/4, distrib. pipe 8 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 192,47 -56,68 3,52 0,00 -5,53 0,00 0,00 30,14
243 Gas Cooler 3/4, distrib. pipe 9 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 193,42 -56,72 3,53 0,00 -5,56 0,00 0,00 30,08
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.58 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
244 Gas Cooler 3/4, distrib. pipe 10 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 194,58 -56,77 3,53 0,00 -5,59 0,00 0,00 30,00
245 Gas Cooler 3/4, distrib. pipe 11 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 195,53 -56,82 3,54 0,00 -5,61 0,00 0,00 29,94
246 Gas Cooler 3/4, distrib. pipe 12 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 196,47 -56,86 3,54 0,00 -5,64 0,00 0,00 29,88
247 Gas Cooler 3/4, distrib. pipe 13 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 197,62 -56,91 3,55 0,00 -5,67 0,00 0,00 29,80
248 Gas Cooler 3/4, distrib. pipe 14 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 198,57 -56,95 3,56 0,00 -5,69 0,00 0,00 29,74
249 Gas Cooler 3/4, distrib. pipe 15 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 199,52 -56,99 3,56 0,00 -5,72 0,00 0,00 29,68
250 Gas Cooler 3/4, distrib. pipe 16 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 200,68 -57,04 3,57 0,00 -5,75 0,00 0,00 29,60
251 Gas Cooler 3/4, distrib. pipe 17 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 201,63 -57,08 3,57 0,00 -5,78 0,00 0,00 29,54
252 Gas Cooler 3/4, distrib. pipe 18 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 202,57 -57,12 3,58 0,00 -5,80 0,00 0,00 29,48
253 Gas Cooler 3/4, distrib. pipe 19 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 203,73 -57,17 3,58 0,00 -5,83 0,00 0,00 29,41
254 Gas Cooler 3/4, distrib. pipe 20 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 204,68 -57,21 3,59 0,00 -5,86 0,00 0,00 29,35
255 Gas Cooler 3/4, distrib. pipe 21 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 205,63 -57,25 3,59 0,00 -5,88 0,00 0,00 29,29
256 Gas Cooler 3/4, distrib. pipe 22 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 206,77 -57,30 3,60 0,00 -5,91 0,00 0,00 29,21
257 Gas Cooler 3/4, distrib. pipe 23 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 207,71 -57,34 3,60 0,00 -5,94 0,00 0,00 29,15
258 Gas Cooler 3/4, distrib. pipe 24 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 208,66 -57,38 3,61 0,00 -5,96 0,00 0,00 29,09
259 Gas Cooler 3/4, distrib. pipe 25 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 209,82 -57,43 3,61 0,00 -5,99 0,00 0,00 29,02
260 Gas Cooler 3/4, distrib. pipe 26 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 210,77 -57,47 3,62 0,00 -6,02 0,00 0,00 28,96
261 Gas Cooler 3/4, distrib. pipe 27 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 211,72 -57,51 3,62 0,00 -6,04 0,00 0,00 28,90
262 Gas Cooler 3/4, distrib. pipe 28 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 212,86 -57,55 3,63 0,00 -6,07 0,00 0,00 28,83
263 Gas Cooler 3/4, distrib. pipe 29 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 213,80 -57,59 3,63 0,00 -6,10 0,00 0,00 28,77
264 Gas Cooler 3/4, distrib. pipe 30 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 214,75 -57,63 3,64 0,00 -6,12 0,00 0,00 28,71
232 Gas Cooler 3/4, gas flow noise Transportation Gas Cooler 0,00 0,00 66,04 496,10 93,00 0,00 200,89 -57,05 3,00 0,00 -2,20 0,00 0,00 36,74
230 Header Discharge side Transportation Gas Cooler 0,00 0,00 78,00 90,45 97,56 0,00 124,54 -52,90 3,20 0,00 -0,77 0,75 0,00 47,84
28 Control valve (enclosed) Unit 1 0,00 0,00 87,00 87,00 3,01 129,42 -53,23 -4,20 0,00 -0,53 0,00 0,00 32,05
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.59 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
23 Exhaust Stack Opening Unit 1 0,00 0,00 84,97 2,01 88,00 0,00 120,74 -52,63 3,00 -3,91 -0,44 1,04 0,00 35,07
24 Exhaust duct outsde compressor Unit 1 0,00 0,00 76,40 12,10 87,23 0,00 122,86 -52,78 3,07 0,00 -1,23 2,41 0,00 38,70
1 Oil Cooler Unit 1 0,00 0,00 78,11 24,50 92,00 0,00 123,17 -52,80 3,00 0,00 -0,51 2,18 0,00 43,87
25 Piping suction side Unit 1 0,00 0,00 78,00 34,38 93,36 0,00 126,29 -53,02 3,15 0,00 -0,79 0,32 0,00 43,03
26 Piping, discharge side Unit 1 0,00 0,00 80,00 30,25 94,81 0,00 136,04 -53,67 3,35 0,00 -0,84 0,50 0,00 44,16
58 Control valve (eingehaust) Unit 3 0,00 0,00 87,00 87,00 3,01 203,00 -57,14 -4,44 0,00 -0,82 0,00 0,00 27,61
31 Exhaust Stack Opening Unit 3 0,00 0,00 84,97 2,01 88,00 0,00 191,47 -56,63 3,00 -7,92 -0,28 0,00 0,00 26,17
53 Exhaust duct outsde compressor Unit 3 0,00 0,00 79,40 6,06 87,23 0,00 194,34 -56,76 4,15 -6,11 -1,01 6,75 0,00 34,24
30 Oil Cooler Unit 3 0,00 0,00 78,11 24,50 92,00 0,00 193,28 -56,72 3,21 - -0,35 5,24 0,00 29,04
54 Piping suction side Unit 3 0,00 0,00 78,00 34,38 93,36 0,00 200,39 -57,03 4,20 0,00 -1,16 0,60 0,00 39,98
55 Piping, discharge side Unit 3 0,00 0,00 80,00 30,25 94,81 0,00 210,20 -57,44 4,29 0,00 -1,21 0,50 0,00 40,95
87 Control valve (eingehaust) Unit 4 0,00 0,00 87,00 87,00 3,01 222,13 -57,92 -4,47 0,00 -0,90 0,00 0,00 26,71
60 Exhaust Stack Opening Unit 4 0,00 0,00 84,97 2,01 88,00 0,00 243,02 -58,70 3,00 -3,64 -0,90 0,00 0,00 27,76
82 Exhaust duct outsde compressor Unit 4 0,00 0,00 79,58 5,82 87,23 0,00 238,61 -58,55 4,49 - -0,29 8,37 0,00 25,86
59 Oil Cooler Unit 4 0,00 0,00 78,11 24,50 92,00 0,00 243,66 -58,73 3,78 - -0,48 2,39 0,00 19,77
83 Piping suction side Unit 4 0,00 0,00 78,00 34,38 93,36 0,00 219,84 -57,83 4,36 0,00 -1,25 0,59 0,00 39,23
84 Piping, discharge side Unit 4 0,00 0,00 80,00 30,25 94,81 0,00 229,43 -58,21 4,43 0,00 -1,29 0,40 0,00 40,14
116 Control valve (eingehaust) Unit 5 0,00 0,00 87,00 87,00 3,01 277,30 -59,85 -4,54 0,00 -1,13 0,00 0,00 24,49
89 Exhaust Stack Opening Unit 5 0,00 0,00 84,97 2,01 88,00 0,00 264,61 -59,44 3,00 -3,63 -0,96 0,00 0,00 26,97
111 Exhaust duct outsde compressor Unit 5 0,00 0,00 79,44 6,01 87,23 0,00 267,79 -59,55 4,66 -8,52 -0,70 0,09 0,00 23,20
88 Oil Cooler Unit 5 0,00 0,00 78,11 24,50 92,00 0,00 265,98 -59,49 3,97 - -0,44 1,07 0,00 22,13
112 Piping suction side Unit 5 0,00 0,00 78,00 34,38 93,36 0,00 272,35 -59,69 4,68 0,00 -1,49 0,02 0,00 36,88
113 Piping, discharge side Unit 5 0,00 0,00 80,00 30,25 94,81 0,00 286,65 -60,14 4,74 0,00 -1,55 0,12 0,00 37,98
330 Air compressor I, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 166,57 -55,42 -4,35 -1,72 -0,39 0,00 0,00 11,13
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.60 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
331 Air compressor II, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 167,85 -55,49 -4,35 -1,71 -0,39 0,00 0,00 11,07
332 Air compressor III, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 169,13 -55,56 -4,36 -1,66 -0,39 0,00 0,00 11,04
320 Air compressor room, ventilation Utility Building 0,00 0,00 68,00 68,00 3,00 170,09 -55,61 -3,59 -1,89 -0,40 0,00 0,00 9,53
354 Air condition unit I Utility Building 0,00 0,00 87,00 87,00 0,00 170,39 -55,62 3,00 - -0,31 2,08 0,00 25,00
353 Air condition unit II Utility Building 0,00 0,00 87,00 87,00 0,00 171,32 -55,67 3,00 - -0,31 2,07 0,00 24,83
333 Boiler room, ventilation intake Utility Building 0,00 0,00 72,00 72,00 6,01 194,38 -56,76 -4,42 -0,99 -0,45 0,00 0,00 15,38
326 Boiler room, ventilation outlet Utility Building 0,00 0,00 72,00 72,00 6,01 178,01 -56,00 -4,22 - -0,42 0,00 0,00 -2,99
321 Boiler, stack opening I Utility Building 0,00 0,00 78,00 78,00 3,01 197,20 -56,89 -3,77 -1,09 -0,46 0,00 0,00 18,80
323 Boiler, stack opening III Utility Building 0,00 0,00 78,00 78,00 3,01 201,29 -57,07 -3,79 -0,99 -0,47 0,00 0,00 18,69
322 Boiler, stack opening Ii Utility Building 0,00 0,00 78,00 78,00 3,01 199,23 -56,98 -3,78 -1,14 -0,46 0,00 0,00 18,64
318 Facade E Utility Building 87,43 37,00 37,28 117,45 57,98 3,00 200,10 -57,02 3,58 - -0,98 0,00 0,00 -15,14
324 Facade N Utility Building 87,43 37,00 37,28 390,90 63,20 3,00 188,90 -56,52 3,46 - -0,96 0,00 0,00 -10,23
325 Facade N, doors Utility Building 87,43 30,00 51,96 22,00 65,38 3,00 187,47 -56,45 4,46 - -3,99 0,00 0,00 -12,18
328 Facade S Utility Building 87,43 37,00 37,28 392,52 63,22 3,00 178,56 -56,03 3,42 -4,51 -1,00 0,00 0,00 8,11
329 Facade S, doors Utility Building 87,43 30,00 51,96 22,00 65,38 3,00 180,57 -56,13 4,41 - -2,70 0,00 0,00 1,65
327 Facade W Utility Building 87,43 37,00 37,28 115,70 57,92 3,00 169,04 -55,55 3,43 - -0,71 0,00 0,00 -3,93
319 Roof Utility Building 87,43 37,00 37,28 595,39 65,03 0,00 183,73 -56,28 3,00 -5,17 -1,11 0,00 0,00 5,47
351 Air condition unit I Workshop/Stores Building 0,00 0,00 87,00 87,00 0,00 109,13 -51,75 3,00 -1,89 -0,28 3,43 0,00 39,52
352 Air condition unit II Workshop/Stores Building 0,00 0,00 87,00 87,00 0,00 110,97 -51,90 3,00 -3,32 -0,25 1,81 0,00 36,34
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.61 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
Name 5 Station Fence South Ln = 57,1 dB(A)
347 Air condition unit I Administration Building 0,00 0,00 87,00 87,00 0,00 405,33 -63,15 4,66 - -0,71 0,00 0,00 11,16
348 Air condition unit II Administration Building 0,00 0,00 87,00 87,00 0,00 408,17 -63,21 4,67 - -0,72 0,00 0,00 11,14
349 Air condition unit III Administration Building 0,00 0,00 87,00 87,00 0,00 409,11 -63,23 4,67 - -0,73 0,00 0,00 13,88
350 Air condition unit IV Administration Building 0,00 0,00 87,00 87,00 0,00 411,80 -63,29 4,68 - -0,74 0,00 0,00 13,51
10 Building vent., exhaust 1 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 285,24 -60,10 2,99 -4,90 -2,42 0,00 0,00 21,58
11 Building vent., exhaust 2 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 289,80 -60,23 2,99 -4,95 -2,36 0,00 0,00 21,45
12 Building vent., exhaust 3 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 280,42 -59,95 2,99 -4,90 -2,40 0,00 0,00 21,74
13 Building vent., exhaust 4 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 285,52 -60,10 2,99 - -0,23 0,00 0,00 18,07
5 Facade N, GT air intake Compressor Building Unit 1 0,00 0,00 74,26 3,75 80,00 3,00 295,56 -60,40 4,24 - -0,21 0,00 0,00 10,18
4 Facade N, build. vent. air intlet Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 298,14 -60,48 5,06 - -0,32 0,00 0,00 0,05
3 Facade N, large door Compressor Building Unit 1 94,00 30,00 59,73 15,57 71,66 3,00 293,54 -60,35 4,68 - -1,20 0,00 0,00 -5,56
6 Facade N, package ventilation, air inlet Compressor Building Unit 1 0,00 0,00 74,02 2,50 78,00 3,00 295,55 -60,40 4,66 - -0,10 0,00 0,00 11,48
22 Facade S, build. vent. air inlet Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 273,89 -59,74 4,98 0,00 -1,62 0,00 0,00 15,68
21 Facade S, door Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 270,77 -59,64 4,96 0,00 -1,47 0,00 0,00 14,87
7 Facade S, small door Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 292,40 -60,31 5,04 - -1,21 0,00 0,00 -8,83
18 Facade W, build. vent. air inlet I Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 294,05 -60,36 5,05 - -0,26 0,00 0,00 3,68
19 Facade W, build. vent. air inlet II Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 282,68 -60,02 5,01 -9,87 -0,27 0,00 0,00 6,91
15 Facade W, door 1 Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 296,80 -60,44 5,05 - -0,93 0,00 0,00 -3,02
16 Facade W, door 2 Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 279,51 -59,92 4,99 - -0,99 0,00 0,00 4,73
17 Facade W, package ventilation outlet Compressor Building Unit 1 0,00 0,00 78,00 1,00 78,00 3,00 287,22 -60,16 4,27 -9,08 -0,10 0,00 0,00 15,94
2 Facade north Compressor Building Unit 1 94,00 48,00 42,00 282,61 66,51 3,00 295,72 -60,41 3,47 - -0,34 0,00 0,00 -4,98
20 Facade south Compressor Building Unit 1 94,00 48,00 42,00 304,43 66,84 3,00 274,32 -59,76 3,47 0,00 -0,61 0,00 0,00 12,94
14 Facade west Compressor Building Unit 1 94,00 48,00 42,00 359,86 67,56 3,00 288,30 -60,19 3,51 - -0,39 0,00 0,00 1,95
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.62 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
8 Roof Compressor Building Unit 1 94,00 45,00 45,41 352,54 70,88 0,00 284,48 -60,07 2,99 -6,05 -0,57 0,00 0,00 7,18
29 air intake duct Compressor Building Unit 1 0,00 0,00 80,00 80,00 0,00 300,16 -60,54 3,59 - -0,19 0,00 0,00 5,68
27 oil demister Compressor Building Unit 1 0,00 0,00 80,00 80,00 0,00 290,12 -60,24 2,99 - -0,77 0,00 0,00 8,58
9 roof, explosion panel Compressor Building Unit 1 94,00 16,00 74,24 100,10 94,24 0,00 285,04 -60,09 2,99 -4,80 -0,83 0,00 0,00 31,52
40 Building vent., exhaust 1 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 264,22 -59,43 2,99 -4,90 -2,23 0,00 0,00 22,44
41 Building vent., exhaust 2 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 269,16 -59,59 2,99 -4,94 -2,14 0,00 0,00 22,32
42 Building vent., exhaust 3 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 262,61 -59,38 2,99 -4,94 -2,24 0,00 0,00 22,45
43 Building vent., exhaust 4 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 268,03 -59,56 2,99 -5,01 -2,14 0,00 0,00 22,29
35 Facade N, GT air intake Compressor Building Unit 3 0,00 0,00 74,26 3,75 80,00 3,00 276,92 -59,84 4,12 - -0,20 0,00 0,00 10,16
34 Facade N, build. vent. air intlet Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 277,86 -59,87 4,99 - -0,27 0,00 0,00 1,35
33 Facade N, large door Compressor Building Unit 3 94,00 30,00 59,73 15,57 71,66 3,00 276,26 -59,82 4,60 - -0,93 0,00 0,00 -1,44
36 Facade N, package ventilation, air inlet Compressor Building Unit 3 0,00 0,00 74,02 2,50 78,00 3,00 276,91 -59,84 4,57 - -0,10 0,00 0,00 11,61
52 Facade S, build. vent. air inlet Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 253,72 -59,08 4,90 0,00 -1,55 0,00 0,00 16,33
51 Facade S, door Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 252,73 -59,05 4,89 0,00 -1,38 0,00 0,00 15,48
37 Facade S, small door Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 275,93 -59,81 4,98 - -1,15 0,00 0,00 -8,40
48 Facade W, build. vent. air inlet I Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 272,79 -59,71 4,97 -8,62 -0,32 0,00 0,00 8,39
49 Facade W, build. vent. air inlet II Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 260,47 -59,31 4,92 -7,08 -0,49 0,00 0,00 10,12
45 Facade W, door 1 Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 275,75 -59,80 4,98 - -0,92 0,00 0,00 3,32
46 Facade W, door 2 Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 257,02 -59,19 4,90 -6,51 -1,16 0,00 0,00 9,06
47 Facade W, package ventilation outlet Compressor Building Unit 3 0,00 0,00 78,00 1,00 78,00 3,00 265,40 -59,47 4,13 -6,28 -0,15 0,00 0,00 19,24
32 Facade north Compressor Building Unit 3 94,00 48,00 42,00 282,61 66,51 3,00 277,06 -59,84 3,38 - -0,31 0,00 0,00 -4,40
50 Facade south Compressor Building Unit 3 94,00 48,00 42,00 304,43 66,84 3,00 253,95 -59,09 3,37 0,00 -0,57 0,00 0,00 13,55
44 Facade west Compressor Building Unit 3 94,00 48,00 42,00 359,86 67,56 3,00 266,53 -59,51 3,38 -7,58 -0,44 0,00 0,00 6,42
38 Roof Compressor Building Unit 3 94,00 45,00 45,41 352,54 70,88 0,00 265,48 -59,47 2,99 -4,73 -0,55 0,00 0,00 9,12
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.63 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
57 air intake duct Compressor Building Unit 3 0,00 0,00 80,00 80,00 0,00 281,53 -59,98 3,43 - -0,19 0,00 0,00 8,46
56 oil demister Compressor Building Unit 3 0,00 0,00 80,00 80,00 0,00 268,28 -59,56 2,99 -7,07 -0,96 0,00 0,00 15,40
39 roof, explosion panel Compressor Building Unit 3 94,00 16,00 74,24 100,10 94,24 0,00 265,84 -59,48 2,99 -4,83 -0,78 0,00 0,00 32,14
69 Building vent., exhaust 1 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 261,90 -59,35 2,99 -4,93 -2,22 0,00 0,00 22,49
70 Building vent., exhaust 2 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 266,88 -59,52 2,99 -4,99 -2,13 0,00 0,00 22,36
71 Building vent., exhaust 3 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 260,70 -59,31 2,99 -4,92 -2,23 0,00 0,00 22,53
72 Building vent., exhaust 4 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 266,69 -59,51 2,99 -5,00 -2,12 0,00 0,00 22,36
80 Facade E, build. vent. air inlet I Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 256,91 -59,19 4,91 0,00 -1,56 0,00 0,00 16,23
81 Facade E, build. vent. air inlet II Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 269,41 -59,60 4,96 0,00 -1,61 0,00 0,00 15,82
78 Facade E, door 1 Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 253,92 -59,09 4,89 0,00 -1,39 0,00 0,00 15,44
77 Facade E, door 2 Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 272,91 -59,71 4,97 0,00 -1,48 0,00 0,00 14,80
79 Facade E, package ventilation, air ou Compressor Building Unit 4 0,00 0,00 78,00 1,00 78,00 3,00 264,42 -59,44 4,13 0,00 -0,59 0,00 0,00 25,10
64 Facade N, GT air intake Compressor Building Unit 4 0,00 0,00 74,26 3,75 80,00 3,00 275,08 -59,78 4,11 - -0,19 0,00 0,00 10,24
63 Facade N, build. vent. air inlet Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 274,82 -59,77 4,98 - -0,27 0,00 0,00 2,60
62 Facade N, large door Compressor Building Unit 4 94,00 30,00 59,73 15,57 71,66 3,00 275,48 -59,79 4,60 - -0,94 0,00 0,00 -2,53
65 Facade N, package ventilation, air i Compressor Building Unit 4 0,00 0,00 74,02 2,50 78,00 3,00 275,07 -59,78 4,56 - -0,10 0,00 0,00 11,68
66 Facade N, small door Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 275,69 -59,80 4,98 - -0,83 0,00 0,00 -3,61
75 Facade S, build. vent. air inlet Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 251,79 -59,01 4,89 0,00 -1,55 0,00 0,00 16,40
74 Facade S, door Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 252,34 -59,03 4,88 0,00 -1,38 0,00 0,00 15,49
76 Facade east Compressor Building Unit 4 94,00 48,00 42,00 359,86 67,56 3,00 262,58 -59,38 3,36 0,00 -0,59 0,00 0,00 13,96
61 Facade north Compressor Building Unit 4 94,00 48,00 42,00 282,61 66,51 3,00 275,18 -59,78 3,37 - -0,32 0,00 0,00 -3,35
73 Facade south Compressor Building Unit 4 94,00 48,00 42,00 304,43 66,84 3,00 251,86 -59,02 3,37 0,00 -0,57 0,00 0,00 13,63
67 Roof Compressor Building Unit 4 94,00 45,00 45,41 352,54 70,88 0,00 263,61 -59,41 2,99 -4,73 -0,54 0,00 0,00 9,18
86 air intake duct Compressor Building Unit 4 0,00 0,00 80,00 80,00 0,00 279,75 -59,93 3,42 - -0,18 0,00 0,00 8,25
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.64 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
85 oil demister Compressor Building Unit 4 0,00 0,00 80,00 80,00 0,00 264,72 -59,45 2,99 0,00 -1,58 0,00 0,00 21,96
68 roof, explosion panel Compressor Building Unit 4 94,00 16,00 74,24 100,10 94,24 0,00 264,04 -59,43 2,99 -4,83 -0,77 0,00 0,00 32,21
98 Building vent., exhaust 1 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 263,00 -59,39 2,99 -4,94 -2,24 0,00 0,00 22,43
99 Building vent., exhaust 2 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 267,96 -59,55 2,99 -5,00 -2,16 0,00 0,00 22,28
100 Building vent., exhaust 3 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 264,95 -59,46 2,99 -4,89 -2,23 0,00 0,00 22,42
101 Building vent., exhaust 4 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 270,29 -59,63 2,99 -4,93 -2,12 0,00 0,00 22,31
93 Facade N, GT air intake Compressor Building Unit 5 0,00 0,00 74,26 3,75 80,00 3,00 277,31 -59,85 4,13 - -0,20 0,00 0,00 10,32
92 Facade N, build. vent. air intlet Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 276,42 -59,82 4,99 - -0,26 0,00 0,00 3,44
91 Facade N, large door Compressor Building Unit 5 94,00 30,00 59,73 15,57 71,66 3,00 278,14 -59,88 4,61 - -0,97 0,00 0,00 -2,90
94 Facade N, package ventilation, air inlet Compressor Building Unit 5 0,00 0,00 74,02 2,50 78,00 3,00 277,30 -59,85 4,57 - -0,10 0,00 0,00 11,71
110 Facade S, build. vent. air inlet Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 254,25 -59,10 4,90 0,00 -1,55 0,00 0,00 16,31
109 Facade S, door Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 255,63 -59,14 4,90 0,00 -1,40 0,00 0,00 15,38
95 Facade S, small door Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 278,68 -59,89 4,99 - -0,88 0,00 0,00 -4,78
106 Facade W, build. vent. air inlet I Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 270,65 -59,64 4,96 0,00 -1,61 0,00 0,00 15,78
107 Facade W, build. vent. air inlet II Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 258,24 -59,23 4,92 0,00 -1,57 0,00 0,00 16,18
103 Facade W, door 1 Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 273,64 -59,74 4,97 0,00 -1,48 0,00 0,00 14,77
104 Facade W, door 2 Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 254,76 -59,11 4,89 0,00 -1,39 0,00 0,00 15,41
105 Facade W, package ventilation outlet Compressor Building Unit 5 0,00 0,00 78,00 1,00 78,00 3,00 263,21 -59,40 4,12 0,00 -0,59 0,00 0,00 25,13
90 Facade north Compressor Building Unit 5 94,00 48,00 42,00 282,61 66,51 3,00 277,41 -59,85 3,38 - -0,32 0,00 0,00 -3,36
108 Facade south Compressor Building Unit 5 94,00 48,00 42,00 304,43 66,84 3,00 254,24 -59,10 3,37 0,00 -0,57 0,00 0,00 13,54
102 Facade west Compressor Building Unit 5 94,00 48,00 42,00 359,86 67,56 3,00 264,31 -59,43 3,37 0,00 -0,59 0,00 0,00 13,91
96 Roof Compressor Building Unit 5 94,00 45,00 45,41 352,54 70,88 0,00 266,00 -59,49 2,99 -4,73 -0,55 0,00 0,00 9,10
115 air intake duct Compressor Building Unit 5 0,00 0,00 80,00 80,00 0,00 282,25 -60,00 3,44 - -0,19 0,00 0,00 8,47
114 oil demister Compressor Building Unit 5 0,00 0,00 80,00 80,00 0,00 266,57 -59,51 2,99 0,00 -1,59 0,00 0,00 21,90
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.65 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
97 roof, explosion panel Compressor Building Unit 5 94,00 16,00 74,24 100,10 94,24 0,00 266,47 -59,50 2,99 -4,83 -0,78 0,00 0,00 32,12
340 Facade E Electrical Building 87,43 37,00 39,28 92,30 58,93 3,00 353,55 -61,96 4,92 - -1,46 0,00 0,00 -6,87
341 Facade E, sec. 1 Electrical Building 87,43 37,00 39,28 127,16 60,33 3,00 365,48 -62,25 4,96 - -1,74 0,00 0,00 -18,64
342 Facade E, sec. 2 Electrical Building 87,43 37,00 39,28 8,11 48,37 3,00 368,28 -62,32 4,97 - -1,74 0,00 0,00 -30,88
343 Facade E, sec. 3 Electrical Building 87,43 37,00 39,28 58,38 56,94 3,00 370,23 -62,36 4,97 - -1,84 0,00 0,00 -23,17
344 Facade E, sec. 4 Electrical Building 87,43 37,00 39,28 2,59 43,42 3,00 371,07 -62,38 4,98 - -1,59 0,00 0,00 -31,74
345 Facade E, sec. 5 Electrical Building 87,43 37,00 39,28 67,56 57,58 3,00 372,26 -62,41 4,98 - -1,59 0,00 0,00 -19,16
334 Facade S, sec. 1 Electrical Building 87,43 37,00 39,28 72,39 57,88 3,00 350,89 -61,90 4,91 0,00 -1,99 0,00 0,00 1,90
336 Facade S, sec. 2 Electrical Building 87,43 37,00 39,28 5,65 46,80 3,00 349,83 -61,87 4,91 -2,26 -1,83 0,00 0,00 -11,25
337 Facade S, sec. 3 Electrical Building 87,43 37,00 39,28 48,15 56,11 3,00 349,46 -61,86 4,90 0,00 -1,98 0,00 0,00 0,17
338 Facade S, sec. 4 Electrical Building 87,43 37,00 39,28 6,42 47,36 3,00 347,91 -61,82 4,91 - -1,46 0,00 0,00 -19,14
339 Facade S, sec. 5 Electrical Building 87,43 37,00 39,28 131,91 60,48 3,00 345,08 -61,75 4,90 - -1,37 0,00 0,00 -9,27
346 Facade W Electrical Building 87,43 37,00 39,28 97,41 59,17 3,00 362,99 -62,19 4,95 - -1,48 0,00 0,00 -8,81
335 Roof Electrical Building 87,43 37,00 39,28 1181,57 70,01 0,00 358,08 -62,07 4,36 -9,74 -1,95 0,00 0,00 0,60
117 Filter I Filter 0,00 0,00 69,83 5,21 77,00 0,00 134,46 -53,56 2,99 0,00 -0,90 0,00 0,00 25,52
118 Filter II Filter 0,00 0,00 69,82 5,22 77,00 0,00 139,90 -53,91 2,99 0,00 -0,93 0,00 0,00 25,15
119 Filter IV Filter 0,00 0,00 69,80 5,25 77,00 0,00 151,86 -54,62 2,99 0,00 -0,99 0,00 0,00 24,38
120 Filter V Filter 0,00 0,00 69,80 5,25 77,00 0,00 158,31 -54,98 2,99 0,00 -1,03 0,00 0,00 23,98
122 Explosion relief panel Fuel Gas Skid I 87,00 16,00 66,62 30,00 81,39 0,00 221,19 -57,89 3,34 -4,71 -0,77 0,00 0,00 21,36
125 Fuel Gas Skid, facade E Fuel Gas Skid I 87,00 37,00 45,32 126,06 66,33 3,00 217,30 -57,73 3,61 0,00 -0,64 0,00 0,00 14,56
126 Fuel Gas Skid, facade E, door Fuel Gas Skid I 87,00 30,00 57,56 4,84 64,41 3,00 221,52 -57,90 4,69 0,00 -1,71 0,00 0,00 12,49
123 Fuel Gas Skid, facade S Fuel Gas Skid I 87,00 37,00 45,32 61,38 63,20 3,00 215,66 -57,67 3,47 0,00 -0,64 0,00 0,00 11,36
124 Fuel Gas Skid, facade S, door Fuel Gas Skid I 87,00 37,00 45,32 7,04 53,80 3,00 215,62 -57,67 4,67 0,00 -0,64 0,00 0,00 3,16
128 Fuel Gas Skid, facade W Fuel Gas Skid I 87,00 37,00 45,32 130,90 66,49 3,00 223,76 -57,99 3,76 -4,36 -0,67 0,00 0,00 10,23
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.66 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
121 Fuel Gas Skid, roof Fuel Gas Skid I 87,00 37,00 45,32 93,97 65,05 0,00 220,86 -57,87 3,34 -4,73 -0,65 0,00 0,00 5,13
127 Ventilation, intake Fuel Gas Skid I 0,00 0,00 68,00 68,00 6,01 219,39 -57,82 -4,38 0,00 -0,51 0,00 0,00 11,30
129 Ventilation, outlet Fuel Gas Skid I 0,00 0,00 68,00 68,00 6,01 220,43 -57,86 -4,38 - -0,51 0,00 0,00 0,10
131 Explosion relief panel Fuel Gas Skid II 87,00 16,00 66,62 30,00 81,39 0,00 231,42 -58,28 3,46 -4,72 -0,80 0,00 0,00 21,05
132 Fuel Gas Skid, facade E Fuel Gas Skid II 87,00 37,00 45,32 126,06 66,33 3,00 228,75 -58,18 3,69 0,00 -0,68 0,00 0,00 14,16
133 Fuel Gas Skid, facade E, door Fuel Gas Skid II 87,00 37,00 45,32 4,84 52,17 3,00 225,32 -58,05 4,73 0,00 -0,67 0,00 0,00 1,18
135 Fuel Gas Skid, facade N Fuel Gas Skid II 87,00 37,00 45,32 63,58 63,35 3,00 236,96 -58,49 3,77 -4,07 -0,70 0,00 0,00 6,87
136 Fuel Gas Skid, facade N, door Fuel Gas Skid II 87,00 37,00 45,32 4,84 52,17 3,00 237,02 -58,49 4,78 - -0,54 0,00 0,00 -14,15
137 Fuel Gas Skid, facade W Fuel Gas Skid II 87,00 37,00 45,32 130,90 66,49 3,00 234,10 -58,38 3,81 -4,63 -0,70 0,00 0,00 9,59
130 Fuel Gas Skid, roof Fuel Gas Skid II 87,00 37,00 45,32 93,97 65,05 0,00 231,30 -58,28 3,46 -4,74 -0,68 0,00 0,00 4,81
134 Ventilation, intake Fuel Gas Skid II 0,00 0,00 68,00 68,00 6,01 232,32 -58,31 -4,40 0,00 -0,54 0,00 0,00 10,75
138 Ventilation, outlet Fuel Gas Skid II 0,00 0,00 68,00 68,00 6,01 230,75 -58,26 -4,40 - -0,54 0,00 0,00 -3,99
296 Meter Run I Metering 0,00 0,00 72,70 39,44 88,66 0,00 181,47 -56,17 3,76 0,00 -1,27 0,00 0,00 34,98
297 Meter Run II Metering 0,00 0,00 72,70 39,45 88,66 0,00 183,67 -56,27 3,79 0,00 -1,29 0,00 0,00 34,89
298 Meter Run IV Metering 0,00 0,00 72,70 39,50 88,66 0,00 188,14 -56,48 3,84 0,00 -1,31 0,00 0,00 34,71
299 Meter Run V Metering 0,00 0,00 72,70 39,48 88,66 0,00 190,39 -56,59 3,86 0,00 -1,33 0,00 0,00 34,61
143 Header discharge side Piping 0,00 0,00 80,00 136,93 101,37 0,00 240,09 -58,60 4,49 0,00 -1,34 1,19 0,00 47,10
233 Header discharge side Piping 0,00 0,00 80,00 89,78 99,53 0,00 226,04 -58,08 4,40 0,00 -1,28 0,88 0,00 45,46
234 Header suction side Piping 0,00 0,00 78,00 93,78 97,72 0,00 223,89 -57,99 4,39 0,00 -1,27 0,85 0,00 43,70
144 Header suction side Piping 0,00 0,00 78,00 108,68 98,36 0,00 236,95 -58,49 4,47 0,00 -1,33 1,03 0,00 44,05
300 Facade E Power Generation Gas I 97,00 37,00 58,49 36,27 74,09 3,00 312,53 -60,89 4,77 0,00 -0,72 0,00 0,00 20,24
302 Facade N Power Generation Gas I 97,00 37,00 58,49 58,24 76,15 3,00 319,56 -61,08 4,81 - -0,52 0,00 0,00 7,90
305 Facade S Power Generation Gas I 97,00 37,00 58,49 53,44 75,77 3,00 312,82 -60,90 4,78 0,00 -0,72 0,00 0,00 21,93
306 Facade S, door Power Generation Gas I 97,00 30,00 64,01 4,84 70,86 3,00 313,73 -60,92 5,07 0,00 -1,26 0,00 0,00 16,75
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.67 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
303 Facade W Power Generation Gas I 97,00 37,00 58,49 36,05 74,06 3,00 319,94 -61,09 4,81 - -0,56 0,00 0,00 8,89
308 Power Generation Gas I, Exhaust Stack Power Generation Gas I 0,00 0,00 90,00 90,00 0,00 312,12 -60,88 3,48 0,00 -0,56 0,00 0,00 32,05
301 Roof Power Generation Gas I 97,00 37,00 58,49 104,04 78,67 0,00 316,31 -60,99 4,14 -4,69 -0,73 0,00 0,00 16,40
304 Room ventilation, intake Power Generation Gas I 0,00 0,00 76,00 76,00 6,01 319,18 -61,07 -4,58 - -0,74 0,00 0,00 4,61
307 Room ventilation, outlet Power Generation Gas I 0,00 0,00 76,00 76,00 6,01 311,65 -60,87 -4,56 0,00 -0,73 0,00 0,00 15,86
313 Facade E Power Generation Gas II 97,00 37,00 58,49 36,40 74,11 3,00 329,32 -61,34 4,83 0,00 -0,76 0,00 0,00 19,83
314 Facade N Power Generation Gas II 97,00 37,00 58,49 53,35 75,77 3,00 336,34 -61,53 4,85 - -0,56 0,00 0,00 7,89
315 Facade N, door Power Generation Gas II 97,00 30,00 64,01 4,84 70,86 3,00 335,52 -61,51 5,14 - -0,60 0,00 0,00 0,94
312 Facade S Power Generation Gas II 97,00 37,00 63,49 58,05 81,13 3,00 329,43 -61,35 4,83 0,00 -0,76 0,00 0,00 26,85
309 Facade W Power Generation Gas II 97,00 37,00 58,49 36,20 74,08 3,00 336,35 -61,53 4,87 - -0,54 0,00 0,00 3,63
317 Power Generation Gas II, Exhaust Stack Power Generation Gas II 0,00 0,00 90,00 90,00 0,00 328,53 -61,32 3,61 0,00 -0,58 0,00 0,00 31,70
311 Roof Power Generation Gas II 97,00 37,00 58,49 104,19 78,67 0,00 332,89 -61,44 4,23 -4,68 -0,76 0,00 0,00 16,02
310 Room ventilation, intake Power Generation Gas II 0,00 0,00 76,00 76,00 6,01 335,58 -61,51 -4,59 - -0,78 0,00 0,00 -1,96
316 Room ventilation, outlet Power Generation Gas II 0,00 0,00 76,00 76,00 6,01 337,44 -61,56 -4,58 - -0,79 0,00 0,00 -0,31
159 Distrib. pipe 1 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 206,86 -57,31 3,54 0,00 -5,83 0,00 0,00 26,71
146 Distrib. pipe 1 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 225,83 -58,07 3,51 0,00 -6,42 0,00 0,00 29,27
160 Distrib. pipe 2 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 206,36 -57,28 3,53 0,00 -5,82 0,00 0,00 26,74
148 Distrib. pipe 2 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 225,35 -58,05 3,51 0,00 -6,41 0,00 0,00 29,29
161 Distrib. pipe 3 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 205,85 -57,26 3,53 0,00 -5,81 0,00 0,00 26,77
149 Distrib. pipe 3 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 224,91 -58,03 3,50 0,00 -6,40 0,00 0,00 29,32
162 Distrib. pipe 4 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 205,26 -57,24 3,53 0,00 -5,79 0,00 0,00 26,81
150 Distrib. pipe 4 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 224,33 -58,01 3,50 0,00 -6,38 0,00 0,00 29,36
163 Distrib. pipe 5 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 204,77 -57,22 3,53 0,00 -5,78 0,00 0,00 26,84
151 Distrib. pipe 5 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 223,86 -57,99 3,50 0,00 -6,37 0,00 0,00 29,39
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.68 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
164 Distrib. pipe 6 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 204,28 -57,20 3,52 0,00 -5,77 0,00 0,00 26,88
152 Distrib. pipe 6 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 223,43 -57,98 3,50 0,00 -6,36 0,00 0,00 29,41
165 Distrib. pipe 7 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 203,67 -57,17 3,52 0,00 -5,75 0,00 0,00 26,91
153 Distrib. pipe 7 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 222,91 -57,95 3,50 0,00 -6,35 0,00 0,00 29,44
166 Distrib. pipe 8 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 203,18 -57,15 3,52 0,00 -5,74 0,00 0,00 26,95
154 Distrib. pipe 8 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 222,45 -57,94 3,49 0,00 -6,33 0,00 0,00 29,47
167 Distrib. pipe 9 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 202,70 -57,13 3,52 0,00 -5,72 0,00 0,00 26,98
155 Distrib. pipe 9 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 222,03 -57,92 3,49 0,00 -6,32 0,00 0,00 29,50
168 Distrib. pipe 10 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 202,13 -57,10 3,51 0,00 -5,71 0,00 0,00 27,01
156 Distrib. pipe 10 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 221,50 -57,90 3,49 0,00 -6,31 0,00 0,00 29,53
169 Distrib. pipe 11 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 201,66 -57,08 3,51 0,00 -5,70 0,00 0,00 27,04
157 Distrib. pipe 11 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 221,05 -57,88 3,49 0,00 -6,30 0,00 0,00 29,56
170 Distrib. pipe 12 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 201,19 -57,06 3,51 0,00 -5,69 0,00 0,00 27,07
158 Distrib. pipe 12 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 220,64 -57,87 3,49 0,00 -6,29 0,00 0,00 29,58
295 Header discharge side, Start Up Cooler Start Up Cooler 0,00 0,00 80,00 94,83 99,77 0,00 222,40 -57,93 4,38 0,00 -1,26 0,83 0,00 45,77
229 Header discharge side, Start Up Cooler Start Up Cooler 0,00 0,00 80,00 164,54 102,16 0,00 235,16 -58,42 4,46 0,00 -1,32 0,92 0,00 47,80
140 Start Up Cooler Start Up Cooler 0,00 0,00 66,17 191,91 89,00 0,00 213,05 -57,56 2,99 0,00 -2,28 0,00 0,00 32,15
142 Start Up Cooler, gas flow noise Start Up Cooler 0,00 0,00 70,16 192,32 93,00 0,00 212,99 -57,56 2,99 0,00 -2,28 0,00 0,00 36,15
147 Distrib. pipe 1 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 201,80 -57,09 3,60 0,00 -5,70 0,00 0,00 26,40
293 Distrib. pipe 1 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 184,01 -56,29 3,50 0,00 -5,24 0,00 0,00 27,57
200 Distrib. pipe 2 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 201,34 -57,07 3,60 0,00 -5,69 0,00 0,00 26,43
294 Distrib. pipe 2 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 183,75 -56,28 3,50 0,00 -5,23 0,00 0,00 27,59
201 Distrib. pipe 3 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 200,88 -57,05 3,59 0,00 -5,68 0,00 0,00 26,46
265 Distrib. pipe 3 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 183,48 -56,26 3,50 0,00 -5,22 0,00 0,00 27,61
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.69 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
202 Distrib. pipe 4 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 200,31 -57,03 3,59 0,00 -5,66 0,00 0,00 26,49
266 Distrib. pipe 4 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 183,15 -56,25 3,50 0,00 -5,21 0,00 0,00 27,63
267 Distrib. pipe 5 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 182,90 -56,24 3,50 0,00 -5,21 0,00 0,00 27,65
203 Distrib. pipe 5 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 199,86 -57,01 3,59 0,00 -5,65 0,00 0,00 26,52
268 Distrib. pipe 6 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 182,65 -56,22 3,50 0,00 -5,20 0,00 0,00 27,66
204 Distrib. pipe 6 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 199,42 -56,99 3,59 0,00 -5,64 0,00 0,00 26,55
269 Distrib. pipe 7 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 182,38 -56,21 3,50 0,00 -5,19 0,00 0,00 27,68
205 Distrib. pipe 7 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 198,91 -56,97 3,58 0,00 -5,63 0,00 0,00 26,58
206 Distrib. pipe 8 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 198,47 -56,95 3,58 0,00 -5,62 0,00 0,00 26,61
270 Distrib. pipe 8 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 182,14 -56,20 3,49 0,00 -5,19 0,00 0,00 27,70
207 Distrib. pipe 9 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 198,04 -56,93 3,58 0,00 -5,60 0,00 0,00 26,64
271 Distrib. pipe 9 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 181,92 -56,19 3,49 0,00 -5,18 0,00 0,00 27,72
272 Distrib. pipe 10 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 181,62 -56,18 3,49 0,00 -5,17 0,00 0,00 27,74
208 Distrib. pipe 10 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 197,50 -56,90 3,58 0,00 -5,59 0,00 0,00 26,68
209 Distrib. pipe 11 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 197,07 -56,88 3,57 0,00 -5,58 0,00 0,00 26,70
273 Distrib. pipe 11 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 181,40 -56,16 3,49 0,00 -5,17 0,00 0,00 27,75
210 Distrib. pipe 12 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 196,65 -56,87 3,57 0,00 -5,57 0,00 0,00 26,73
274 Distrib. pipe 12 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 181,18 -56,15 3,49 0,00 -5,16 0,00 0,00 27,77
211 Distrib. pipe 13 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 196,12 -56,84 3,57 0,00 -5,55 0,00 0,00 26,77
275 Distrib. pipe 13 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 180,91 -56,14 3,49 0,00 -5,15 0,00 0,00 27,79
212 Distrib. pipe 14 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 195,71 -56,82 3,57 0,00 -5,54 0,00 0,00 26,79
276 Distrib. pipe 14 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 180,70 -56,13 3,49 0,00 -5,15 0,00 0,00 27,80
213 Distrib. pipe 15 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 195,30 -56,81 3,56 0,00 -5,53 0,00 0,00 26,82
277 Distrib. pipe 15 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 180,50 -56,12 3,49 0,00 -5,14 0,00 0,00 27,81
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.70 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
278 Distrib. pipe 16 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 180,24 -56,11 3,48 0,00 -5,14 0,00 0,00 27,83
214 Distrib. pipe 16 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 194,79 -56,78 3,56 0,00 -5,52 0,00 0,00 26,85
215 Distrib. pipe 17 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 194,39 -56,77 3,56 0,00 -5,51 0,00 0,00 26,88
279 Distrib. pipe 17 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 180,05 -56,10 3,48 0,00 -5,13 0,00 0,00 27,84
216 Distrib. pipe 18 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 193,99 -56,75 3,56 0,00 -5,50 0,00 0,00 26,90
280 Distrib. pipe 18 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 179,87 -56,09 3,48 0,00 -5,13 0,00 0,00 27,86
217 Distrib. pipe 19 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 193,54 -56,73 3,56 0,00 -5,49 0,00 0,00 26,93
281 Distrib. pipe 19 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 179,67 -56,08 3,48 0,00 -5,12 0,00 0,00 27,87
282 Distrib. pipe 20 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 179,50 -56,07 3,48 0,00 -5,12 0,00 0,00 27,88
218 Distrib. pipe 20 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 193,15 -56,71 3,55 0,00 -5,48 0,00 0,00 26,96
283 Distrib. pipe 21 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 179,33 -56,07 3,48 0,00 -5,11 0,00 0,00 27,89
219 Distrib. pipe 21 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 192,77 -56,69 3,55 0,00 -5,47 0,00 0,00 26,98
220 Distrib. pipe 22 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 192,28 -56,67 3,55 0,00 -5,45 0,00 0,00 27,02
284 Distrib. pipe 22 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 179,11 -56,05 3,48 0,00 -5,11 0,00 0,00 27,91
285 Distrib. pipe 23 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 178,95 -56,05 3,48 0,00 -5,10 0,00 0,00 27,92
221 Distrib. pipe 23 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 191,91 -56,65 3,55 0,00 -5,44 0,00 0,00 27,04
222 Distrib. pipe 24 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 191,54 -56,64 3,54 0,00 -5,43 0,00 0,00 27,07
286 Distrib. pipe 24 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 178,80 -56,04 3,48 0,00 -5,10 0,00 0,00 27,93
287 Distrib. pipe 25 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 178,65 -56,03 3,48 0,00 -5,09 0,00 0,00 27,94
223 Distrib. pipe 25 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 191,12 -56,62 3,54 0,00 -5,42 0,00 0,00 27,09
224 Distrib. pipe 26 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 190,76 -56,60 3,54 0,00 -5,41 0,00 0,00 27,12
288 Distrib. pipe 26 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 178,50 -56,03 3,48 0,00 -5,09 0,00 0,00 27,95
289 Distrib. pipe 27 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 178,37 -56,02 3,47 0,00 -5,09 0,00 0,00 27,96
225 Distrib. pipe 27 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 190,40 -56,59 3,54 0,00 -5,40 0,00 0,00 27,14
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.71 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
290 Distrib. pipe 28 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 178,19 -56,01 3,47 0,00 -5,08 0,00 0,00 27,97
226 Distrib. pipe 28 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 189,95 -56,56 3,54 0,00 -5,39 0,00 0,00 27,17
227 Distrib. pipe 29 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 189,60 -56,55 3,53 0,00 -5,38 0,00 0,00 27,19
291 Distrib. pipe 29 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 178,06 -56,00 3,47 0,00 -5,08 0,00 0,00 27,98
292 Distrib. pipe 30 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 177,94 -56,00 3,47 0,00 -5,08 0,00 0,00 27,99
228 Distrib. pipe 30 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 189,25 -56,53 3,53 0,00 -5,37 0,00 0,00 27,22
139 Gas Cooler 1/2 Transportation Gas Cooler 0,00 0,00 66,05 495,71 93,00 0,00 203,32 -57,16 2,99 0,00 -2,22 0,00 0,00 36,61
145 Gas Cooler 1/2, distrib. pipe 1 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 217,77 -57,75 3,65 0,00 -6,21 0,00 0,00 28,52
171 Gas Cooler 1/2, distrib. pipe 2 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 217,34 -57,74 3,65 0,00 -6,19 0,00 0,00 28,55
172 Gas Cooler 1/2, distrib. pipe 3 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 216,92 -57,72 3,65 0,00 -6,18 0,00 0,00 28,57
173 Gas Cooler 1/2, distrib. pipe 4 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 216,41 -57,70 3,64 0,00 -6,17 0,00 0,00 28,60
174 Gas Cooler 1/2, distrib. pipe 5 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 216,00 -57,68 3,64 0,00 -6,16 0,00 0,00 28,63
175 Gas Cooler 1/2, distrib. pipe 6 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 215,59 -57,66 3,64 0,00 -6,15 0,00 0,00 28,65
176 Gas Cooler 1/2, distrib. pipe 7 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 215,10 -57,64 3,64 0,00 -6,14 0,00 0,00 28,68
177 Gas Cooler 1/2, distrib. pipe 8 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 214,70 -57,63 3,63 0,00 -6,12 0,00 0,00 28,71
178 Gas Cooler 1/2, distrib. pipe 9 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 214,30 -57,61 3,63 0,00 -6,11 0,00 0,00 28,73
179 Gas Cooler 1/2, distrib. pipe 10 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 213,79 -57,59 3,63 0,00 -6,10 0,00 0,00 28,77
180 Gas Cooler 1/2, distrib. pipe 11 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 213,40 -57,58 3,63 0,00 -6,09 0,00 0,00 28,79
181 Gas Cooler 1/2, distrib. pipe 12 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 213,01 -57,56 3,63 0,00 -6,08 0,00 0,00 28,81
182 Gas Cooler 1/2, distrib. pipe 13 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 212,57 -57,54 3,62 0,00 -6,07 0,00 0,00 28,84
183 Gas Cooler 1/2, distrib. pipe 14 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 212,19 -57,53 3,62 0,00 -6,06 0,00 0,00 28,87
184 Gas Cooler 1/2, distrib. pipe 15 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 211,81 -57,51 3,62 0,00 -6,05 0,00 0,00 28,89
185 Gas Cooler 1/2, distrib. pipe 16 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 211,35 -57,49 3,62 0,00 -6,04 0,00 0,00 28,92
186 Gas Cooler 1/2, distrib. pipe 17 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 210,98 -57,48 3,62 0,00 -6,03 0,00 0,00 28,94
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.72 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
187 Gas Cooler 1/2, distrib. pipe 18 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 210,62 -57,46 3,61 0,00 -6,02 0,00 0,00 28,96
188 Gas Cooler 1/2, distrib. pipe 19 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 210,13 -57,44 3,61 0,00 -6,00 0,00 0,00 28,99
189 Gas Cooler 1/2, distrib. pipe 20 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 209,78 -57,43 3,61 0,00 -5,99 0,00 0,00 29,02
190 Gas Cooler 1/2, distrib. pipe 21 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 209,43 -57,41 3,61 0,00 -5,98 0,00 0,00 29,04
191 Gas Cooler 1/2, distrib. pipe 22 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 209,01 -57,40 3,61 0,00 -5,97 0,00 0,00 29,07
192 Gas Cooler 1/2, distrib. pipe 23 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 208,67 -57,38 3,60 0,00 -5,96 0,00 0,00 29,09
193 Gas Cooler 1/2, distrib. pipe 24 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 208,33 -57,37 3,60 0,00 -5,96 0,00 0,00 29,11
194 Gas Cooler 1/2, distrib. pipe 25 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 207,91 -57,35 3,60 0,00 -5,94 0,00 0,00 29,14
195 Gas Cooler 1/2, distrib. pipe 26 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 207,58 -57,34 3,60 0,00 -5,94 0,00 0,00 29,16
196 Gas Cooler 1/2, distrib. pipe 27 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 207,25 -57,32 3,60 0,00 -5,93 0,00 0,00 29,18
197 Gas Cooler 1/2, distrib. pipe 28 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 206,87 -57,31 3,60 0,00 -5,92 0,00 0,00 29,20
198 Gas Cooler 1/2, distrib. pipe 29 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 206,55 -57,29 3,59 0,00 -5,91 0,00 0,00 29,22
199 Gas Cooler 1/2, distrib. pipe 30 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 206,23 -57,28 3,59 0,00 -5,90 0,00 0,00 29,24
141 Gas Cooler 1/2, gas flow noise Transportation Gas Cooler 0,00 0,00 66,05 495,71 93,00 0,00 203,32 -57,16 2,99 0,00 -2,22 0,00 0,00 36,61
231 Gas Cooler 3/4 Transportation Gas Cooler 0,00 0,00 66,04 496,15 93,00 0,00 189,24 -56,53 2,99 0,00 -2,13 0,00 0,00 37,33
235 Gas Cooler 3/4, distrib. pipe 1 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 201,40 -57,07 3,57 0,00 -5,77 0,00 0,00 29,55
236 Gas Cooler 3/4, distrib. pipe 2 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 201,16 -57,06 3,57 0,00 -5,76 0,00 0,00 29,57
237 Gas Cooler 3/4, distrib. pipe 3 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 200,92 -57,05 3,57 0,00 -5,76 0,00 0,00 29,58
238 Gas Cooler 3/4, distrib. pipe 4 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 200,64 -57,04 3,56 0,00 -5,75 0,00 0,00 29,60
239 Gas Cooler 3/4, distrib. pipe 5 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 200,41 -57,03 3,56 0,00 -5,74 0,00 0,00 29,62
240 Gas Cooler 3/4, distrib. pipe 6 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 200,18 -57,02 3,56 0,00 -5,74 0,00 0,00 29,63
241 Gas Cooler 3/4, distrib. pipe 7 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 199,92 -57,01 3,56 0,00 -5,73 0,00 0,00 29,65
242 Gas Cooler 3/4, distrib. pipe 8 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 199,71 -57,00 3,56 0,00 -5,73 0,00 0,00 29,66
243 Gas Cooler 3/4, distrib. pipe 9 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 199,50 -56,99 3,56 0,00 -5,72 0,00 0,00 29,68
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.73 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
244 Gas Cooler 3/4, distrib. pipe 10 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 199,22 -56,98 3,56 0,00 -5,71 0,00 0,00 29,69
245 Gas Cooler 3/4, distrib. pipe 11 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 199,03 -56,97 3,56 0,00 -5,71 0,00 0,00 29,71
246 Gas Cooler 3/4, distrib. pipe 12 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 198,83 -56,96 3,55 0,00 -5,70 0,00 0,00 29,72
247 Gas Cooler 3/4, distrib. pipe 13 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 198,62 -56,95 3,55 0,00 -5,70 0,00 0,00 29,73
248 Gas Cooler 3/4, distrib. pipe 14 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 198,43 -56,94 3,55 0,00 -5,69 0,00 0,00 29,74
249 Gas Cooler 3/4, distrib. pipe 15 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 198,25 -56,94 3,55 0,00 -5,69 0,00 0,00 29,76
250 Gas Cooler 3/4, distrib. pipe 16 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 198,03 -56,93 3,55 0,00 -5,68 0,00 0,00 29,77
251 Gas Cooler 3/4, distrib. pipe 17 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 197,86 -56,92 3,55 0,00 -5,68 0,00 0,00 29,78
252 Gas Cooler 3/4, distrib. pipe 18 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 197,69 -56,91 3,55 0,00 -5,67 0,00 0,00 29,79
253 Gas Cooler 3/4, distrib. pipe 19 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 197,45 -56,90 3,55 0,00 -5,66 0,00 0,00 29,81
254 Gas Cooler 3/4, distrib. pipe 20 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 197,29 -56,89 3,55 0,00 -5,66 0,00 0,00 29,82
255 Gas Cooler 3/4, distrib. pipe 21 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 197,13 -56,89 3,55 0,00 -5,66 0,00 0,00 29,83
256 Gas Cooler 3/4, distrib. pipe 22 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 196,96 -56,88 3,54 0,00 -5,65 0,00 0,00 29,84
257 Gas Cooler 3/4, distrib. pipe 23 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 196,82 -56,87 3,54 0,00 -5,65 0,00 0,00 29,85
258 Gas Cooler 3/4, distrib. pipe 24 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 196,68 -56,87 3,54 0,00 -5,64 0,00 0,00 29,86
259 Gas Cooler 3/4, distrib. pipe 25 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 196,51 -56,86 3,54 0,00 -5,64 0,00 0,00 29,87
260 Gas Cooler 3/4, distrib. pipe 26 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 196,38 -56,85 3,54 0,00 -5,64 0,00 0,00 29,88
261 Gas Cooler 3/4, distrib. pipe 27 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 196,26 -56,85 3,54 0,00 -5,63 0,00 0,00 29,89
262 Gas Cooler 3/4, distrib. pipe 28 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 196,12 -56,84 3,54 0,00 -5,63 0,00 0,00 29,90
263 Gas Cooler 3/4, distrib. pipe 29 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 196,01 -56,84 3,54 0,00 -5,63 0,00 0,00 29,90
264 Gas Cooler 3/4, distrib. pipe 30 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 195,90 -56,83 3,54 0,00 -5,62 0,00 0,00 29,91
232 Gas Cooler 3/4, gas flow noise Transportation Gas Cooler 0,00 0,00 66,04 496,10 93,00 0,00 189,24 -56,53 2,99 0,00 -2,13 0,00 0,00 37,33
230 Header Discharge side Transportation Gas Cooler 0,00 0,00 78,00 90,45 97,56 0,00 224,81 -58,03 4,38 0,00 -1,27 0,46 0,00 43,11
28 Control valve (enclosed) Unit 1 0,00 0,00 87,00 87,00 3,01 268,95 -59,59 -4,53 0,00 -1,09 0,00 0,00 24,80
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.74 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
23 Exhaust Stack Opening Unit 1 0,00 0,00 84,97 2,01 88,00 0,00 289,79 -60,23 2,99 -3,61 -1,03 0,00 0,00 26,12
24 Exhaust duct outsde compressor Unit 1 0,00 0,00 76,40 12,10 87,23 0,00 287,56 -60,17 4,74 -7,91 -0,90 0,00 0,00 22,99
1 Oil Cooler Unit 1 0,00 0,00 78,11 24,50 92,00 0,00 296,56 -60,43 4,17 -7,11 -0,76 0,00 0,00 27,87
25 Piping suction side Unit 1 0,00 0,00 78,00 34,38 93,36 0,00 261,00 -59,33 4,61 0,00 -1,44 1,74 0,00 38,96
26 Piping, discharge side Unit 1 0,00 0,00 80,00 30,25 94,81 0,00 257,71 -59,21 4,60 0,00 -1,42 2,18 0,00 40,95
58 Control valve (eingehaust) Unit 3 0,00 0,00 87,00 87,00 3,01 247,62 -58,87 -4,51 0,00 -1,01 2,33 0,00 27,96
31 Exhaust Stack Opening Unit 3 0,00 0,00 84,97 2,01 88,00 0,00 265,69 -59,48 2,99 -3,64 -0,96 0,00 0,00 26,91
53 Exhaust duct outsde compressor Unit 3 0,00 0,00 79,40 6,06 87,23 0,00 264,38 -59,44 4,63 0,00 -2,12 0,00 0,00 30,31
30 Oil Cooler Unit 3 0,00 0,00 78,11 24,50 92,00 0,00 273,23 -59,72 4,02 0,00 -1,03 0,00 0,00 35,26
54 Piping suction side Unit 3 0,00 0,00 78,00 34,38 93,36 0,00 238,67 -58,55 4,48 0,00 -1,34 1,67 0,00 39,64
55 Piping, discharge side Unit 3 0,00 0,00 80,00 30,25 94,81 0,00 235,81 -58,44 4,47 0,00 -1,32 2,05 0,00 41,55
87 Control valve (eingehaust) Unit 4 0,00 0,00 87,00 87,00 3,01 245,58 -58,80 -4,50 0,00 -1,00 2,32 0,00 28,04
60 Exhaust Stack Opening Unit 4 0,00 0,00 84,97 2,01 88,00 0,00 260,65 -59,31 2,99 -3,61 -0,95 0,00 0,00 27,12
82 Exhaust duct outsde compressor Unit 4 0,00 0,00 79,58 5,82 87,23 0,00 260,03 -59,29 4,61 0,00 -2,09 0,00 0,00 30,45
59 Oil Cooler Unit 4 0,00 0,00 78,11 24,50 92,00 0,00 268,38 -59,57 3,98 -3,41 -0,83 0,00 0,00 32,17
83 Piping suction side Unit 4 0,00 0,00 78,00 34,38 93,36 0,00 234,46 -58,39 4,46 0,00 -1,32 1,63 0,00 39,74
84 Piping, discharge side Unit 4 0,00 0,00 80,00 30,25 94,81 0,00 236,30 -58,46 4,47 0,00 -1,33 2,15 0,00 41,64
116 Control valve (eingehaust) Unit 5 0,00 0,00 87,00 87,00 3,01 248,10 -58,88 -4,51 0,00 -1,01 2,33 0,00 27,94
89 Exhaust Stack Opening Unit 5 0,00 0,00 84,97 2,01 88,00 0,00 261,75 -59,35 2,99 -3,57 -0,94 0,00 0,00 27,13
111 Exhaust duct outsde compressor Unit 5 0,00 0,00 79,44 6,01 87,23 0,00 261,45 -59,34 4,62 0,00 -2,10 0,00 0,00 30,40
88 Oil Cooler Unit 5 0,00 0,00 78,11 24,50 92,00 0,00 269,45 -59,60 3,99 -3,50 -0,80 0,00 0,00 32,09
112 Piping suction side Unit 5 0,00 0,00 78,00 34,38 93,36 0,00 237,16 -58,49 4,48 0,00 -1,33 1,68 0,00 39,70
113 Piping, discharge side Unit 5 0,00 0,00 80,00 30,25 94,81 0,00 239,85 -58,59 4,49 0,00 -1,34 2,15 0,00 41,52
330 Air compressor I, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 366,83 -62,28 -4,61 - -0,86 0,00 0,00 -7,90
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.75 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
331 Air compressor II, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 366,13 -62,26 -4,61 - -0,85 0,00 0,00 -7,71
332 Air compressor III, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 365,43 -62,25 -4,60 - -0,85 0,00 0,00 -7,99
320 Air compressor room, ventilation Utility Building 0,00 0,00 68,00 68,00 3,01 374,11 -62,45 -4,28 -9,50 -0,87 0,00 0,00 -6,09
354 Air condition unit I Utility Building 0,00 0,00 87,00 87,00 0,00 376,20 -62,50 4,56 - -0,71 0,00 0,00 7,89
353 Air condition unit II Utility Building 0,00 0,00 87,00 87,00 0,00 377,26 -62,52 4,56 - -0,71 0,00 0,00 7,82
333 Boiler room, ventilation intake Utility Building 0,00 0,00 72,00 72,00 6,01 354,57 -61,99 -4,60 0,00 -0,83 0,00 0,00 10,60
326 Boiler room, ventilation outlet Utility Building 0,00 0,00 72,00 72,00 6,01 378,24 -62,55 -4,54 - -0,88 0,00 0,00 -9,36
321 Boiler, stack opening I Utility Building 0,00 0,00 78,00 78,00 3,01 358,52 -62,08 -4,25 -0,51 -0,84 0,00 0,00 13,33
323 Boiler, stack opening III Utility Building 0,00 0,00 78,00 78,00 3,01 364,33 -62,22 -4,26 -0,48 -0,85 0,00 0,00 13,20
322 Boiler, stack opening Ii Utility Building 0,00 0,00 78,00 78,00 3,01 361,43 -62,15 -4,26 -0,50 -0,84 0,00 0,00 13,26
318 Facade E Utility Building 87,43 37,00 37,28 117,45 57,98 3,00 360,29 -62,13 4,37 0,00 -2,03 0,00 0,00 1,20
324 Facade N Utility Building 87,43 37,00 37,28 390,90 63,20 3,00 372,85 -62,42 4,46 - -1,79 0,00 0,00 -16,54
325 Facade N, doors Utility Building 87,43 30,00 51,96 22,00 65,38 3,00 373,47 -62,44 5,23 - -6,19 0,00 0,00 -19,47
328 Facade S Utility Building 87,43 37,00 37,28 392,52 63,22 3,00 360,62 -62,13 4,36 -6,04 -1,87 0,00 0,00 0,54
329 Facade S, doors Utility Building 87,43 30,00 51,96 22,00 65,38 3,00 359,90 -62,12 5,20 - -4,33 0,00 0,00 -10,36
327 Facade W Utility Building 87,43 37,00 37,28 115,70 57,92 3,00 374,17 -62,45 4,47 - -1,77 0,00 0,00 -21,45
319 Roof Utility Building 87,43 37,00 37,28 595,39 65,03 0,00 366,90 -62,28 3,30 -7,52 -2,02 0,00 0,00 -3,49
351 Air condition unit I Workshop/Stores Building 0,00 0,00 87,00 87,00 0,00 349,30 -61,86 4,44 0,00 -0,86 0,00 0,00 28,73
352 Air condition unit II Workshop/Stores Building 0,00 0,00 87,00 87,00 0,00 347,73 -61,82 4,44 0,00 -0,85 0,00 0,00 28,77
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.76 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
Name 6 Station Fence East Ln = 54,2 dB(A)
347 Air condition unit I Administration Building 0,00 0,00 87,00 87,00 0,00 477,43 -64,57 4,85 - -0,86 0,00 0,00 9,57
348 Air condition unit II Administration Building 0,00 0,00 87,00 87,00 0,00 482,88 -64,67 4,86 - -0,87 0,00 0,00 9,30
349 Air condition unit III Administration Building 0,00 0,00 87,00 87,00 0,00 489,58 -64,79 4,88 - -0,87 0,00 0,00 7,80
350 Air condition unit IV Administration Building 0,00 0,00 87,00 87,00 0,00 491,10 -64,82 4,88 - -0,88 0,00 0,00 8,10
10 Building vent., exhaust 1 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 371,21 -62,38 2,99 -9,46 -0,35 0,00 0,00 16,79
11 Building vent., exhaust 2 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 373,19 -62,43 2,99 - -0,35 0,00 0,00 16,12
12 Building vent., exhaust 3 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 359,77 -62,11 2,99 - -0,28 0,00 0,00 13,42
13 Building vent., exhaust 4 on roof Compressor Building Unit 1 0,00 0,00 86,00 86,00 0,00 362,10 -62,17 2,99 - -0,28 0,00 0,00 13,39
5 Facade N, GT air intake Compressor Building Unit 1 0,00 0,00 74,26 3,75 80,00 3,00 371,46 -62,39 4,59 - -0,23 0,00 0,00 8,46
4 Facade N, build. vent. air intlet Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 377,57 -62,53 5,25 - -0,36 0,00 0,00 -2,13
3 Facade N, large door Compressor Building Unit 1 94,00 30,00 59,73 15,57 71,66 3,00 366,49 -62,27 4,94 - -1,16 0,00 0,00 -4,91
6 Facade N, package ventilation, air inlet Compressor Building Unit 1 0,00 0,00 74,02 2,50 78,00 3,00 371,46 -62,39 4,93 - -0,11 0,00 0,00 10,24
22 Facade S, build. vent. air inlet Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 361,72 -62,16 5,22 0,00 -1,88 0,00 0,00 13,25
21 Facade S, door Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 354,33 -61,98 5,20 0,00 -1,85 0,00 0,00 12,39
7 Facade S, small door Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 363,58 -62,20 5,22 - -1,14 0,00 0,00 -7,95
18 Facade W, build. vent. air inlet I Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 377,49 -62,53 5,25 - -0,45 0,00 0,00 -3,40
19 Facade W, build. vent. air inlet II Compressor Building Unit 1 94,00 38,00 63,05 4,00 69,07 3,00 372,56 -62,42 5,24 - -0,33 0,00 0,00 -0,19
15 Facade W, door 1 Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 378,72 -62,56 5,25 - -1,33 0,00 0,00 -9,30
16 Facade W, door 2 Compressor Building Unit 1 94,00 25,00 64,73 2,13 68,02 3,00 371,25 -62,39 5,23 - -1,12 0,00 0,00 -3,43
17 Facade W, package ventilation outlet Compressor Building Unit 1 0,00 0,00 78,00 1,00 78,00 3,00 374,49 -62,46 4,67 - -0,13 0,00 0,00 9,15
2 Facade north Compressor Building Unit 1 94,00 48,00 42,00 282,61 66,51 3,00 371,48 -62,39 3,79 - -0,38 0,00 0,00 -6,96
20 Facade south Compressor Building Unit 1 94,00 48,00 42,00 304,43 66,84 3,00 362,35 -62,17 3,78 0,00 -0,80 0,00 0,00 10,65
14 Facade west Compressor Building Unit 1 94,00 48,00 42,00 359,86 67,56 3,00 375,16 -62,48 3,89 - -0,45 0,00 0,00 -4,92
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.77 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
8 Roof Compressor Building Unit 1 94,00 45,00 45,41 352,54 70,88 0,00 366,08 -62,26 2,98 -9,09 -0,61 0,00 0,00 1,89
29 air intake duct Compressor Building Unit 1 0,00 0,00 80,00 80,00 0,00 373,16 -62,43 4,05 - -0,27 0,00 0,00 10,16
27 oil demister Compressor Building Unit 1 0,00 0,00 80,00 80,00 0,00 376,58 -62,51 2,99 - -1,06 0,00 0,00 0,25
9 roof, explosion panel Compressor Building Unit 1 94,00 16,00 74,24 100,10 94,24 0,00 366,33 -62,27 2,98 - -0,61 0,00 0,00 21,72
40 Building vent., exhaust 1 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 303,98 -60,65 2,99 -4,99 -2,47 2,09 0,00 22,96
41 Building vent., exhaust 2 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 306,42 -60,72 2,99 -5,11 -2,38 0,00 0,00 20,78
42 Building vent., exhaust 3 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 293,12 -60,33 2,99 -4,99 -2,35 0,00 0,00 21,31
43 Building vent., exhaust 4 on roof Compressor Building Unit 3 0,00 0,00 86,00 86,00 0,00 295,96 -60,42 2,99 -5,10 -2,25 0,00 0,00 21,22
35 Facade N, GT air intake Compressor Building Unit 3 0,00 0,00 74,26 3,75 80,00 3,00 305,73 -60,70 4,29 - -0,20 0,00 0,00 8,77
34 Facade N, build. vent. air intlet Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 311,50 -60,86 5,09 - -0,37 0,00 0,00 -1,59
33 Facade N, large door Compressor Building Unit 3 94,00 30,00 59,73 15,57 71,66 3,00 301,05 -60,56 4,71 - -1,05 0,00 0,00 -4,16
36 Facade N, package ventilation, air inlet Compressor Building Unit 3 0,00 0,00 74,02 2,50 78,00 3,00 305,73 -60,70 4,70 - -0,10 0,00 0,00 10,60
52 Facade S, build. vent. air inlet Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 293,87 -60,36 5,04 0,00 -1,69 0,00 0,00 15,07
51 Facade S, door Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 286,82 -60,14 5,01 0,00 -1,54 0,00 0,00 14,34
37 Facade S, small door Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 298,31 -60,49 5,05 - -1,03 0,00 0,00 -7,15
48 Facade W, build. vent. air inlet I Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 310,81 -60,84 5,09 - -0,40 0,00 0,00 -1,60
49 Facade W, build. vent. air inlet II Compressor Building Unit 3 94,00 38,00 63,05 4,00 69,07 3,00 304,79 -60,67 5,08 - -0,29 0,00 0,00 1,84
45 Facade W, door 1 Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 312,31 -60,88 5,09 - -1,13 0,00 0,00 -7,58
46 Facade W, door 2 Compressor Building Unit 3 94,00 25,00 64,73 2,13 68,02 3,00 303,17 -60,63 5,07 - -0,94 0,00 0,00 -1,20
47 Facade W, package ventilation outlet Compressor Building Unit 3 0,00 0,00 78,00 1,00 78,00 3,00 307,15 -60,74 4,38 - -0,10 0,00 0,00 11,20
32 Facade north Compressor Building Unit 3 94,00 48,00 42,00 282,61 66,51 3,00 305,71 -60,70 3,52 - -0,33 0,00 0,00 -5,91
50 Facade south Compressor Building Unit 3 94,00 48,00 42,00 304,43 66,84 3,00 294,43 -60,37 3,56 0,00 -0,66 0,00 0,00 12,37
44 Facade west Compressor Building Unit 3 94,00 48,00 42,00 359,86 67,56 3,00 307,97 -60,76 3,59 - -0,38 0,00 0,00 -2,91
38 Roof Compressor Building Unit 3 94,00 45,00 45,41 352,54 70,88 0,00 299,48 -60,52 2,98 -4,77 -0,62 0,00 0,00 7,95
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.78 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
57 air intake duct Compressor Building Unit 3 0,00 0,00 80,00 80,00 0,00 307,66 -60,75 3,64 - -0,21 0,00 0,00 9,11
56 oil demister Compressor Building Unit 3 0,00 0,00 80,00 80,00 0,00 309,43 -60,80 2,99 - -0,86 0,00 0,00 2,79
39 roof, explosion panel Compressor Building Unit 3 94,00 16,00 74,24 100,10 94,24 0,00 299,54 -60,52 2,98 -4,82 -0,87 0,00 0,00 31,02
69 Building vent., exhaust 1 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 286,71 -60,14 2,99 -5,09 -2,35 0,00 0,00 21,41
70 Building vent., exhaust 2 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 289,29 -60,22 2,99 -5,08 -2,36 0,00 0,00 21,33
71 Building vent., exhaust 3 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 275,79 -59,80 2,99 -4,78 -2,45 0,00 0,00 21,96
72 Building vent., exhaust 4 on roof Compressor Building Unit 4 0,00 0,00 86,00 86,00 0,00 279,01 -59,90 2,99 - -0,24 0,00 0,00 17,21
80 Facade E, build. vent. air inlet I Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 270,69 -59,64 4,96 0,00 -1,61 0,00 0,00 15,77
81 Facade E, build. vent. air inlet II Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 277,48 -59,86 4,98 0,00 -1,63 0,00 0,00 15,56
78 Facade E, door 1 Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 269,12 -59,59 4,95 0,00 -1,46 0,00 0,00 14,91
77 Facade E, door 2 Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 279,45 -59,92 4,99 0,00 -1,51 0,00 0,00 14,58
79 Facade E, package ventilation, air ou Compressor Building Unit 4 0,00 0,00 78,00 1,00 78,00 3,00 274,72 -59,77 4,19 -2,54 -0,25 0,00 0,00 22,63
64 Facade N, GT air intake Compressor Building Unit 4 0,00 0,00 74,26 3,75 80,00 3,00 288,15 -60,18 4,19 - -0,22 0,00 0,00 14,23
63 Facade N, build. vent. air inlet Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 282,98 -60,03 5,00 -9,95 -0,27 0,00 0,00 6,83
62 Facade N, large door Compressor Building Unit 4 94,00 30,00 59,73 15,57 71,66 3,00 293,48 -60,34 4,68 - -0,94 0,00 0,00 -0,70
65 Facade N, package ventilation, air i Compressor Building Unit 4 0,00 0,00 74,02 2,50 78,00 3,00 288,15 -60,18 4,62 - -0,09 0,00 0,00 15,06
66 Facade N, small door Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 295,71 -60,41 5,04 - -0,95 0,00 0,00 -4,38
75 Facade S, build. vent. air inlet Compressor Building Unit 4 94,00 38,00 63,05 4,00 69,07 3,00 276,40 -59,82 4,98 0,00 -1,63 0,00 0,00 15,59
74 Facade S, door Compressor Building Unit 4 94,00 25,00 64,73 2,13 68,02 3,00 282,94 -60,03 5,00 0,00 -1,53 0,00 0,00 14,47
76 Facade east Compressor Building Unit 4 94,00 48,00 42,00 359,86 67,56 3,00 274,00 -59,75 3,42 -0,01 -0,61 0,00 0,00 13,61
61 Facade north Compressor Building Unit 4 94,00 48,00 42,00 282,61 66,51 3,00 287,52 -60,17 3,42 - -0,37 0,00 0,00 0,02
73 Facade south Compressor Building Unit 4 94,00 48,00 42,00 304,43 66,84 3,00 275,44 -59,79 3,37 0,00 -0,62 0,00 0,00 12,79
67 Roof Compressor Building Unit 4 94,00 45,00 45,41 352,54 70,88 0,00 282,14 -60,00 2,98 -4,73 -0,59 0,00 0,00 8,53
86 air intake duct Compressor Building Unit 4 0,00 0,00 80,00 80,00 0,00 291,36 -60,28 3,51 -6,81 -0,29 0,00 0,00 16,13
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.79 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
85 oil demister Compressor Building Unit 4 0,00 0,00 80,00 80,00 0,00 274,27 -59,76 2,99 -3,91 -1,24 0,00 0,00 18,08
68 roof, explosion panel Compressor Building Unit 4 94,00 16,00 74,24 100,10 94,24 0,00 282,48 -60,01 2,98 -5,02 -0,82 0,00 0,00 31,38
98 Building vent., exhaust 1 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 240,96 -58,63 2,99 -5,49 -1,92 0,00 0,00 22,95
99 Building vent., exhaust 2 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 244,02 -58,74 2,99 -5,64 -1,82 0,00 0,00 22,79
100 Building vent., exhaust 3 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 231,20 -58,27 2,99 -4,97 -2,16 0,00 0,00 23,59
101 Building vent., exhaust 4 on roof Compressor Building Unit 5 0,00 0,00 86,00 86,00 0,00 234,75 -58,40 2,99 -4,93 -2,16 0,00 0,00 23,50
93 Facade N, GT air intake Compressor Building Unit 5 0,00 0,00 74,26 3,75 80,00 3,00 244,93 -58,77 3,87 - -0,18 0,00 0,00 13,96
92 Facade N, build. vent. air intlet Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 250,08 -58,95 4,87 - -0,27 0,00 0,00 2,48
91 Facade N, large door Compressor Building Unit 5 94,00 30,00 59,73 15,57 71,66 3,00 240,78 -58,62 4,39 - -0,76 0,00 0,00 3,26
94 Facade N, package ventilation, air inlet Compressor Building Unit 5 0,00 0,00 74,02 2,50 78,00 3,00 244,92 -58,77 4,38 - -0,08 0,00 0,00 15,05
110 Facade S, build. vent. air inlet Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 230,07 -58,23 4,78 0,00 -1,46 0,00 0,00 17,15
109 Facade S, door Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 223,69 -57,99 4,74 0,00 -1,24 0,00 0,00 16,53
95 Facade S, small door Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 238,36 -58,54 4,81 - -0,79 0,00 0,00 3,79
106 Facade W, build. vent. air inlet I Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 248,48 -58,90 4,87 - -0,30 0,00 0,00 1,18
107 Facade W, build. vent. air inlet II Compressor Building Unit 5 94,00 38,00 63,05 4,00 69,07 3,00 240,92 -58,63 4,83 - -0,24 0,00 0,00 4,40
103 Facade W, door 1 Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 250,36 -58,96 4,87 - -0,88 0,00 0,00 -4,99
104 Facade W, door 2 Compressor Building Unit 5 94,00 25,00 64,73 2,13 68,02 3,00 238,87 -58,56 4,82 - -0,76 0,00 0,00 1,61
105 Facade W, package ventilation outlet Compressor Building Unit 5 0,00 0,00 78,00 1,00 78,00 3,00 243,90 -58,74 3,96 - -0,08 0,00 0,00 13,43
90 Facade north Compressor Building Unit 5 94,00 48,00 42,00 282,61 66,51 3,00 245,10 -58,78 3,25 - -0,31 0,00 0,00 0,01
108 Facade south Compressor Building Unit 5 94,00 48,00 42,00 304,43 66,84 3,00 230,52 -58,25 3,25 0,00 -0,52 0,00 0,00 14,32
102 Facade west Compressor Building Unit 5 94,00 48,00 42,00 359,86 67,56 3,00 244,59 -58,76 3,27 - -0,30 0,00 0,00 -0,09
96 Roof Compressor Building Unit 5 94,00 45,00 45,41 352,54 70,88 0,00 237,50 -58,51 2,98 -4,76 -0,49 0,00 0,00 10,09
115 air intake duct Compressor Building Unit 5 0,00 0,00 80,00 80,00 0,00 247,60 -58,87 3,07 -8,31 -0,22 0,00 0,00 15,68
114 oil demister Compressor Building Unit 5 0,00 0,00 80,00 80,00 0,00 246,82 -58,84 2,98 - -0,71 0,00 0,00 5,19
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.80 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
97 roof, explosion panel Compressor Building Unit 5 94,00 16,00 74,24 100,10 94,24 0,00 237,48 -58,50 2,98 -4,89 -0,69 0,00 0,00 33,14
340 Facade E Electrical Building 87,43 37,00 39,28 92,30 58,93 3,00 347,06 -61,80 4,89 0,00 -1,97 0,00 0,00 3,05
341 Facade E, sec. 1 Electrical Building 87,43 37,00 39,28 127,16 60,33 3,00 364,62 -62,23 4,95 - -1,51 0,00 0,00 -14,55
342 Facade E, sec. 2 Electrical Building 87,43 37,00 39,28 8,11 48,37 3,00 375,74 -62,49 4,98 - -1,64 0,00 0,00 -29,30
343 Facade E, sec. 3 Electrical Building 87,43 37,00 39,28 58,38 56,94 3,00 381,22 -62,62 5,00 - -1,82 0,00 0,00 -22,85
344 Facade E, sec. 4 Electrical Building 87,43 37,00 39,28 2,59 43,42 3,00 385,96 -62,72 5,01 - -1,85 0,00 0,00 -36,62
345 Facade E, sec. 5 Electrical Building 87,43 37,00 39,28 67,56 57,58 3,00 391,48 -62,85 5,02 - -1,87 0,00 0,00 -22,56
334 Facade S, sec. 1 Electrical Building 87,43 37,00 39,28 72,39 57,88 3,00 377,38 -62,53 4,99 - -1,48 0,00 0,00 -10,55
336 Facade S, sec. 2 Electrical Building 87,43 37,00 39,28 5,65 46,80 3,00 371,53 -62,39 4,97 - -1,44 0,00 0,00 -22,82
337 Facade S, sec. 3 Electrical Building 87,43 37,00 39,28 48,15 56,11 3,00 367,72 -62,30 4,96 - -1,43 0,00 0,00 -13,86
338 Facade S, sec. 4 Electrical Building 87,43 37,00 39,28 6,42 47,36 3,00 363,16 -62,19 4,95 - -1,63 0,00 0,00 -30,10
339 Facade S, sec. 5 Electrical Building 87,43 37,00 39,28 131,91 60,48 3,00 351,31 -61,91 4,91 - -1,39 0,00 0,00 -7,60
346 Facade W Electrical Building 87,43 37,00 39,28 97,41 59,17 3,00 390,56 -62,83 5,02 - -1,80 0,00 0,00 -19,96
335 Roof Electrical Building 87,43 37,00 39,28 1181,57 70,01 0,00 369,30 -62,34 4,40 - -1,39 0,00 0,00 -5,91
117 Filter I Filter 0,00 0,00 69,83 5,21 77,00 0,00 303,65 -60,64 3,91 0,00 -1,64 0,00 0,00 18,63
118 Filter II Filter 0,00 0,00 69,82 5,22 77,00 0,00 312,61 -60,89 3,97 0,00 -1,67 0,00 0,00 18,41
119 Filter IV Filter 0,00 0,00 69,80 5,25 77,00 0,00 330,66 -61,38 4,08 0,00 -1,73 0,00 0,00 17,97
120 Filter V Filter 0,00 0,00 69,80 5,25 77,00 0,00 339,68 -61,61 4,13 0,00 -1,77 0,00 0,00 17,75
122 Explosion relief panel Fuel Gas Skid I 87,00 16,00 66,62 30,00 81,39 0,00 392,49 -62,87 4,49 -4,71 -1,25 0,00 0,00 17,06
125 Fuel Gas Skid, facade E Fuel Gas Skid I 87,00 37,00 45,32 126,06 66,33 3,00 388,40 -62,78 4,54 0,00 -1,13 0,00 0,00 9,96
126 Fuel Gas Skid, facade E, door Fuel Gas Skid I 87,00 30,00 57,56 4,84 64,41 3,00 388,99 -62,79 5,25 0,00 -2,58 0,00 0,00 7,28
123 Fuel Gas Skid, facade S Fuel Gas Skid I 87,00 37,00 45,32 61,38 63,20 3,00 391,74 -62,85 4,57 0,00 -1,14 0,00 0,00 6,78
124 Fuel Gas Skid, facade S, door Fuel Gas Skid I 87,00 37,00 45,32 7,04 53,80 3,00 391,71 -62,85 5,26 0,00 -1,14 0,00 0,00 -1,93
128 Fuel Gas Skid, facade W Fuel Gas Skid I 87,00 37,00 45,32 130,90 66,49 3,00 396,48 -62,96 4,60 -4,26 -1,16 0,00 0,00 5,71
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.81 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
121 Fuel Gas Skid, roof Fuel Gas Skid I 87,00 37,00 45,32 93,97 65,05 0,00 392,47 -62,87 4,50 -4,72 -1,13 0,00 0,00 0,83
127 Ventilation, intake Fuel Gas Skid I 0,00 0,00 68,00 68,00 6,01 388,66 -62,78 -4,57 0,00 -0,91 0,00 0,00 5,75
129 Ventilation, outlet Fuel Gas Skid I 0,00 0,00 68,00 68,00 6,01 396,02 -62,95 -4,57 - -0,92 0,00 0,00 -7,64
131 Explosion relief panel Fuel Gas Skid II 87,00 16,00 66,62 30,00 81,39 0,00 394,27 -62,91 4,50 -4,71 -1,26 0,00 0,00 17,02
132 Fuel Gas Skid, facade E Fuel Gas Skid II 87,00 37,00 45,32 126,06 66,33 3,00 390,30 -62,82 4,56 0,00 -1,13 0,00 0,00 9,93
133 Fuel Gas Skid, facade E, door Fuel Gas Skid II 87,00 37,00 45,32 4,84 52,17 3,00 389,62 -62,80 5,26 0,00 -1,13 0,00 0,00 -3,51
135 Fuel Gas Skid, facade N Fuel Gas Skid II 87,00 37,00 45,32 63,58 63,35 3,00 395,32 -62,93 4,57 -2,77 -1,14 0,00 0,00 4,09
136 Fuel Gas Skid, facade N, door Fuel Gas Skid II 87,00 37,00 45,32 4,84 52,17 3,00 395,41 -62,93 5,26 -6,53 -1,03 0,00 0,00 -10,06
137 Fuel Gas Skid, facade W Fuel Gas Skid II 87,00 37,00 45,32 130,90 66,49 3,00 398,24 -63,00 4,61 -4,26 -1,16 0,00 0,00 5,68
130 Fuel Gas Skid, roof Fuel Gas Skid II 87,00 37,00 45,32 93,97 65,05 0,00 394,24 -62,91 4,50 -4,72 -1,14 0,00 0,00 0,78
134 Ventilation, intake Fuel Gas Skid II 0,00 0,00 68,00 68,00 6,01 390,95 -62,83 -4,57 0,00 -0,91 0,00 0,00 5,69
138 Ventilation, outlet Fuel Gas Skid II 0,00 0,00 68,00 68,00 6,01 397,58 -62,98 -4,57 - -0,93 0,00 0,00 -7,64
296 Meter Run I Metering 0,00 0,00 72,70 39,44 88,66 0,00 353,42 -61,96 4,85 0,00 -2,27 0,00 0,00 29,28
297 Meter Run II Metering 0,00 0,00 72,70 39,45 88,66 0,00 356,41 -62,03 4,86 0,00 -2,28 0,00 0,00 29,20
298 Meter Run IV Metering 0,00 0,00 72,70 39,50 88,66 0,00 362,41 -62,18 4,88 0,00 -2,32 0,00 0,00 29,05
299 Meter Run V Metering 0,00 0,00 72,70 39,48 88,66 0,00 365,41 -62,25 4,89 0,00 -2,33 0,00 0,00 28,97
143 Header discharge side Piping 0,00 0,00 80,00 136,93 101,37 0,00 325,45 -61,24 4,87 0,00 -1,70 0,12 0,00 43,41
233 Header discharge side Piping 0,00 0,00 80,00 89,78 99,53 0,00 236,19 -58,46 4,45 0,00 -1,32 0,54 0,00 44,74
234 Header suction side Piping 0,00 0,00 78,00 93,78 97,72 0,00 236,91 -58,48 4,46 0,00 -1,33 0,51 0,00 42,88
144 Header suction side Piping 0,00 0,00 78,00 108,68 98,36 0,00 321,21 -61,13 4,86 0,00 -1,69 0,00 0,00 40,41
300 Facade E Power Generation Gas I 97,00 37,00 58,49 36,27 74,09 3,00 425,18 -63,56 5,09 0,00 -0,97 0,00 0,00 17,64
302 Facade N Power Generation Gas I 97,00 37,00 58,49 58,24 76,15 3,00 432,56 -63,71 5,11 -9,90 -0,78 0,00 0,00 9,86
305 Facade S Power Generation Gas I 97,00 37,00 58,49 53,44 75,77 3,00 429,68 -63,65 5,10 0,00 -0,98 0,00 0,00 19,23
306 Facade S, door Power Generation Gas I 97,00 30,00 64,01 4,84 70,86 3,00 431,23 -63,69 5,32 0,00 -1,60 0,00 0,00 13,89
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.82 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
303 Facade W Power Generation Gas I 97,00 37,00 58,49 36,05 74,06 3,00 437,40 -63,81 5,12 - -0,71 0,00 0,00 3,46
308 Power Generation Gas I, Exhaust Stack Power Generation Gas I 0,00 0,00 90,00 90,00 0,00 424,40 -63,55 4,14 0,00 -0,73 0,00 0,00 29,86
301 Roof Power Generation Gas I 97,00 37,00 58,49 104,04 78,67 0,00 431,33 -63,69 4,63 -4,71 -0,98 0,00 0,00 13,92
304 Room ventilation, intake Power Generation Gas I 0,00 0,00 76,00 76,00 6,01 437,06 -63,80 -4,64 - -1,02 0,00 0,00 -1,80
307 Room ventilation, outlet Power Generation Gas I 0,00 0,00 76,00 76,00 6,01 427,83 -63,62 -4,62 0,00 -1,00 0,00 0,00 12,77
313 Facade E Power Generation Gas II 97,00 37,00 58,49 36,40 74,11 3,00 432,40 -63,71 5,10 -8,67 -0,81 0,00 0,00 9,01
314 Facade N Power Generation Gas II 97,00 37,00 58,49 53,35 75,77 3,00 440,04 -63,86 5,11 - -0,72 0,00 0,00 -0,69
315 Facade N, door Power Generation Gas II 97,00 30,00 64,01 4,84 70,86 3,00 438,67 -63,83 5,33 - -0,92 0,00 0,00 -6,08
312 Facade S Power Generation Gas II 97,00 37,00 63,49 58,05 81,13 3,00 436,78 -63,80 5,11 0,00 -1,00 0,00 0,00 24,44
309 Facade W Power Generation Gas II 97,00 37,00 58,49 36,20 74,08 3,00 444,40 -63,95 5,13 - -0,76 0,00 0,00 1,28
317 Power Generation Gas II, Exhaust Stack Power Generation Gas II 0,00 0,00 90,00 90,00 0,00 431,45 -63,69 4,17 -5,64 -0,32 0,00 0,00 24,51
311 Roof Power Generation Gas II 97,00 37,00 58,49 104,19 78,67 0,00 438,46 -63,83 4,65 - -0,70 0,00 0,00 5,33
310 Room ventilation, intake Power Generation Gas II 0,00 0,00 76,00 76,00 6,01 444,03 -63,94 -4,64 - -1,04 0,00 0,00 -3,12
316 Room ventilation, outlet Power Generation Gas II 0,00 0,00 76,00 76,00 6,01 441,99 -63,90 -4,63 - -1,03 0,00 0,00 -6,41
159 Distrib. pipe 1 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 340,48 -61,63 4,23 0,00 -9,18 0,00 0,00 19,73
146 Distrib. pipe 1 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 345,10 -61,75 4,11 0,00 -9,48 0,00 0,00 23,13
160 Distrib. pipe 2 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 339,55 -61,61 4,22 0,00 -9,15 0,00 0,00 19,77
148 Distrib. pipe 2 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 344,16 -61,73 4,10 0,00 -9,46 0,00 0,00 23,17
161 Distrib. pipe 3 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 338,62 -61,59 4,22 0,00 -9,13 0,00 0,00 19,81
149 Distrib. pipe 3 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 343,22 -61,70 4,10 0,00 -9,43 0,00 0,00 23,21
162 Distrib. pipe 4 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 337,47 -61,56 4,21 0,00 -9,10 0,00 0,00 19,86
150 Distrib. pipe 4 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 342,15 -61,68 4,09 0,00 -9,41 0,00 0,00 23,26
163 Distrib. pipe 5 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 336,54 -61,53 4,21 0,00 -9,08 0,00 0,00 19,91
151 Distrib. pipe 5 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 341,21 -61,65 4,09 0,00 -9,38 0,00 0,00 23,30
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.83 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
164 Distrib. pipe 6 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 335,61 -61,51 4,20 0,00 -9,06 0,00 0,00 19,95
152 Distrib. pipe 6 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 340,27 -61,63 4,08 0,00 -9,36 0,00 0,00 23,34
165 Distrib. pipe 7 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 334,46 -61,48 4,20 0,00 -9,03 0,00 0,00 20,00
153 Distrib. pipe 7 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 339,17 -61,60 4,08 0,00 -9,33 0,00 0,00 23,39
166 Distrib. pipe 8 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 333,53 -61,45 4,19 0,00 -9,01 0,00 0,00 20,04
154 Distrib. pipe 8 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 338,24 -61,58 4,07 0,00 -9,31 0,00 0,00 23,43
167 Distrib. pipe 9 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 332,60 -61,43 4,19 0,00 -8,99 0,00 0,00 20,08
155 Distrib. pipe 9 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 337,30 -61,55 4,07 0,00 -9,29 0,00 0,00 23,48
168 Distrib. pipe 10 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 331,45 -61,40 4,18 0,00 -8,96 0,00 0,00 20,13
156 Distrib. pipe 10 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 336,19 -61,52 4,06 0,00 -9,26 0,00 0,00 23,52
169 Distrib. pipe 11 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 330,52 -61,38 4,17 0,00 -8,94 0,00 0,00 20,18
157 Distrib. pipe 11 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 335,26 -61,50 4,06 0,00 -9,24 0,00 0,00 23,57
170 Distrib. pipe 12 downstream Start Up Cooler 0,00 0,00 76,00 10,75 86,31 0,00 329,59 -61,35 4,17 0,00 -8,92 0,00 0,00 20,22
158 Distrib. pipe 12 upstream Start Up Cooler 0,00 0,00 79,00 13,33 90,25 0,00 334,32 -61,48 4,05 0,00 -9,21 0,00 0,00 23,61
295 Header discharge side, Start Up Cooler Start Up Cooler 0,00 0,00 80,00 94,83 99,77 0,00 235,64 -58,44 4,45 0,00 -1,32 0,40 0,00 44,86
229 Header discharge side, Start Up Cooler Start Up Cooler 0,00 0,00 80,00 164,54 102,16 0,00 328,07 -61,31 4,88 0,00 -1,71 0,00 0,00 44,02
140 Start Up Cooler Start Up Cooler 0,00 0,00 66,17 191,91 89,00 0,00 337,19 -61,55 3,32 0,00 -2,89 0,00 0,00 27,88
142 Start Up Cooler, gas flow noise Start Up Cooler 0,00 0,00 70,16 192,32 93,00 0,00 337,19 -61,55 3,32 0,00 -2,89 0,00 0,00 31,88
147 Distrib. pipe 1 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 328,73 -61,33 4,29 0,00 -8,89 0,00 0,00 19,66
293 Distrib. pipe 1 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 283,73 -60,05 4,03 0,00 -7,79 0,00 0,00 21,78
200 Distrib. pipe 2 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 327,80 -61,30 4,29 0,00 -8,87 0,00 0,00 19,70
294 Distrib. pipe 2 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 282,80 -60,02 4,03 0,00 -7,77 0,00 0,00 21,83
201 Distrib. pipe 3 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 326,87 -61,28 4,28 0,00 -8,85 0,00 0,00 19,74
265 Distrib. pipe 3 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 281,86 -59,99 4,02 0,00 -7,74 0,00 0,00 21,88
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.84 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
202 Distrib. pipe 4 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 325,71 -61,25 4,28 0,00 -8,82 0,00 0,00 19,80
266 Distrib. pipe 4 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 280,72 -59,96 4,02 0,00 -7,72 0,00 0,00 21,93
267 Distrib. pipe 5 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 279,79 -59,93 4,01 0,00 -7,69 0,00 0,00 21,98
203 Distrib. pipe 5 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 324,78 -61,22 4,27 0,00 -8,80 0,00 0,00 19,84
268 Distrib. pipe 6 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 278,87 -59,90 4,01 0,00 -7,67 0,00 0,00 22,03
204 Distrib. pipe 6 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 323,85 -61,20 4,27 0,00 -8,78 0,00 0,00 19,88
269 Distrib. pipe 7 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 277,75 -59,87 4,00 0,00 -7,64 0,00 0,00 22,09
205 Distrib. pipe 7 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 322,72 -61,17 4,26 0,00 -8,75 0,00 0,00 19,93
206 Distrib. pipe 8 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 321,79 -61,14 4,25 0,00 -8,73 0,00 0,00 19,98
270 Distrib. pipe 8 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 276,82 -59,84 4,00 0,00 -7,62 0,00 0,00 22,13
207 Distrib. pipe 9 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 320,86 -61,12 4,25 0,00 -8,70 0,00 0,00 20,02
271 Distrib. pipe 9 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 275,90 -59,81 3,99 0,00 -7,60 0,00 0,00 22,18
272 Distrib. pipe 10 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 274,75 -59,77 3,98 0,00 -7,57 0,00 0,00 22,24
208 Distrib. pipe 10 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 319,71 -61,09 4,24 0,00 -8,68 0,00 0,00 20,07
209 Distrib. pipe 11 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 318,78 -61,06 4,24 0,00 -8,65 0,00 0,00 20,12
273 Distrib. pipe 11 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 273,83 -59,74 3,98 0,00 -7,54 0,00 0,00 22,29
210 Distrib. pipe 12 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 317,85 -61,04 4,23 0,00 -8,63 0,00 0,00 20,16
274 Distrib. pipe 12 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 272,91 -59,71 3,97 0,00 -7,52 0,00 0,00 22,33
211 Distrib. pipe 13 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 316,70 -61,01 4,23 0,00 -8,60 0,00 0,00 20,21
275 Distrib. pipe 13 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 271,77 -59,68 3,97 0,00 -7,49 0,00 0,00 22,39
212 Distrib. pipe 14 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 315,77 -60,98 4,22 0,00 -8,58 0,00 0,00 20,25
276 Distrib. pipe 14 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 270,85 -59,65 3,96 0,00 -7,47 0,00 0,00 22,44
213 Distrib. pipe 15 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 314,84 -60,95 4,22 0,00 -8,56 0,00 0,00 20,30
277 Distrib. pipe 15 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 269,92 -59,62 3,96 0,00 -7,45 0,00 0,00 22,49
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.85 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
278 Distrib. pipe 16 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 268,78 -59,58 3,95 0,00 -7,42 0,00 0,00 22,55
214 Distrib. pipe 16 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 313,69 -60,92 4,21 0,00 -8,53 0,00 0,00 20,35
215 Distrib. pipe 17 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 312,76 -60,90 4,21 0,00 -8,51 0,00 0,00 20,40
279 Distrib. pipe 17 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 267,86 -59,55 3,95 0,00 -7,39 0,00 0,00 22,60
216 Distrib. pipe 18 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 311,83 -60,87 4,20 0,00 -8,48 0,00 0,00 20,44
280 Distrib. pipe 18 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 266,93 -59,52 3,94 0,00 -7,37 0,00 0,00 22,65
217 Distrib. pipe 19 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 310,70 -60,84 4,19 0,00 -8,46 0,00 0,00 20,49
281 Distrib. pipe 19 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 265,82 -59,48 3,94 0,00 -7,34 0,00 0,00 22,70
282 Distrib. pipe 20 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 264,89 -59,45 3,93 0,00 -7,32 0,00 0,00 22,75
218 Distrib. pipe 20 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 309,77 -60,81 4,19 0,00 -8,43 0,00 0,00 20,53
283 Distrib. pipe 21 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 263,97 -59,42 3,93 0,00 -7,30 0,00 0,00 22,80
219 Distrib. pipe 21 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 308,84 -60,79 4,18 0,00 -8,41 0,00 0,00 20,58
220 Distrib. pipe 22 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 307,69 -60,75 4,18 0,00 -8,38 0,00 0,00 20,63
284 Distrib. pipe 22 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 262,83 -59,39 3,92 0,00 -7,27 0,00 0,00 22,86
285 Distrib. pipe 23 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 261,91 -59,36 3,92 0,00 -7,24 0,00 0,00 22,91
221 Distrib. pipe 23 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 306,76 -60,73 4,17 0,00 -8,36 0,00 0,00 20,68
222 Distrib. pipe 24 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 305,84 -60,70 4,17 0,00 -8,34 0,00 0,00 20,72
286 Distrib. pipe 24 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 260,98 -59,32 3,91 0,00 -7,22 0,00 0,00 22,96
287 Distrib. pipe 25 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 259,86 -59,29 3,91 0,00 -7,19 0,00 0,00 23,02
223 Distrib. pipe 25 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 304,70 -60,67 4,16 0,00 -8,31 0,00 0,00 20,77
224 Distrib. pipe 26 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 303,77 -60,64 4,16 0,00 -8,29 0,00 0,00 20,82
288 Distrib. pipe 26 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 258,94 -59,26 3,90 0,00 -7,17 0,00 0,00 23,07
289 Distrib. pipe 27 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 258,02 -59,23 3,90 0,00 -7,15 0,00 0,00 23,12
225 Distrib. pipe 27 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 302,84 -60,62 4,15 0,00 -8,26 0,00 0,00 20,86
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.86 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
290 Distrib. pipe 28 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 256,88 -59,19 3,89 0,00 -7,12 0,00 0,00 23,18
226 Distrib. pipe 28 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 301,70 -60,58 4,14 0,00 -8,24 0,00 0,00 20,92
227 Distrib. pipe 29 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 300,77 -60,56 4,14 0,00 -8,21 0,00 0,00 20,96
291 Distrib. pipe 29 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 255,96 -59,16 3,89 0,00 -7,09 0,00 0,00 23,23
292 Distrib. pipe 30 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 255,04 -59,12 3,88 0,00 -7,07 0,00 0,00 23,28
228 Distrib. pipe 30 downstream Transportation Gas Cooler 0,00 0,00 76,00 9,10 85,59 0,00 299,84 -60,53 4,13 0,00 -8,19 0,00 0,00 21,00
139 Gas Cooler 1/2 Transportation Gas Cooler 0,00 0,00 66,05 495,71 93,00 0,00 316,30 -60,99 3,14 0,00 -2,80 0,00 0,00 32,35
145 Gas Cooler 1/2, distrib. pipe 1 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 332,60 -61,43 4,27 0,00 -9,17 0,00 0,00 22,49
171 Gas Cooler 1/2, distrib. pipe 2 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 331,68 -61,41 4,26 0,00 -9,15 0,00 0,00 22,54
172 Gas Cooler 1/2, distrib. pipe 3 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 330,76 -61,38 4,26 0,00 -9,12 0,00 0,00 22,58
173 Gas Cooler 1/2, distrib. pipe 4 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 329,63 -61,35 4,25 0,00 -9,09 0,00 0,00 22,63
174 Gas Cooler 1/2, distrib. pipe 5 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 328,71 -61,33 4,25 0,00 -9,07 0,00 0,00 22,67
175 Gas Cooler 1/2, distrib. pipe 6 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 327,78 -61,30 4,24 0,00 -9,05 0,00 0,00 22,72
176 Gas Cooler 1/2, distrib. pipe 7 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 326,67 -61,27 4,24 0,00 -9,02 0,00 0,00 22,77
177 Gas Cooler 1/2, distrib. pipe 8 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 325,75 -61,25 4,23 0,00 -9,00 0,00 0,00 22,81
178 Gas Cooler 1/2, distrib. pipe 9 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 324,83 -61,23 4,23 0,00 -8,97 0,00 0,00 22,85
179 Gas Cooler 1/2, distrib. pipe 10 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 323,69 -61,19 4,22 0,00 -8,95 0,00 0,00 22,91
180 Gas Cooler 1/2, distrib. pipe 11 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 322,77 -61,17 4,21 0,00 -8,92 0,00 0,00 22,95
181 Gas Cooler 1/2, distrib. pipe 12 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 321,85 -61,15 4,21 0,00 -8,90 0,00 0,00 22,99
182 Gas Cooler 1/2, distrib. pipe 13 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 320,73 -61,12 4,20 0,00 -8,87 0,00 0,00 23,05
183 Gas Cooler 1/2, distrib. pipe 14 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 319,82 -61,09 4,20 0,00 -8,85 0,00 0,00 23,09
184 Gas Cooler 1/2, distrib. pipe 15 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 318,90 -61,07 4,19 0,00 -8,82 0,00 0,00 23,13
185 Gas Cooler 1/2, distrib. pipe 16 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 317,76 -61,03 4,19 0,00 -8,80 0,00 0,00 23,19
186 Gas Cooler 1/2, distrib. pipe 17 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 316,84 -61,01 4,18 0,00 -8,77 0,00 0,00 23,23
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.87 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
187 Gas Cooler 1/2, distrib. pipe 18 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 315,92 -60,98 4,18 0,00 -8,75 0,00 0,00 23,27
188 Gas Cooler 1/2, distrib. pipe 19 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 314,79 -60,95 4,17 0,00 -8,72 0,00 0,00 23,33
189 Gas Cooler 1/2, distrib. pipe 20 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 313,87 -60,93 4,17 0,00 -8,70 0,00 0,00 23,37
190 Gas Cooler 1/2, distrib. pipe 21 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 312,95 -60,90 4,16 0,00 -8,67 0,00 0,00 23,41
191 Gas Cooler 1/2, distrib. pipe 22 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 311,85 -60,87 4,15 0,00 -8,65 0,00 0,00 23,46
192 Gas Cooler 1/2, distrib. pipe 23 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 310,93 -60,85 4,15 0,00 -8,62 0,00 0,00 23,51
193 Gas Cooler 1/2, distrib. pipe 24 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 310,01 -60,82 4,14 0,00 -8,60 0,00 0,00 23,55
194 Gas Cooler 1/2, distrib. pipe 25 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 308,88 -60,79 4,14 0,00 -8,57 0,00 0,00 23,61
195 Gas Cooler 1/2, distrib. pipe 26 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 307,96 -60,76 4,13 0,00 -8,55 0,00 0,00 23,65
196 Gas Cooler 1/2, distrib. pipe 27 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 307,05 -60,74 4,13 0,00 -8,52 0,00 0,00 23,69
197 Gas Cooler 1/2, distrib. pipe 28 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 305,94 -60,70 4,12 0,00 -8,50 0,00 0,00 23,75
198 Gas Cooler 1/2, distrib. pipe 29 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 305,03 -60,68 4,11 0,00 -8,47 0,00 0,00 23,79
199 Gas Cooler 1/2, distrib. pipe 30 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 304,11 -60,65 4,11 0,00 -8,45 0,00 0,00 23,83
141 Gas Cooler 1/2, gas flow noise Transportation Gas Cooler 0,00 0,00 66,05 495,71 93,00 0,00 316,31 -60,99 3,14 0,00 -2,80 0,00 0,00 32,35
231 Gas Cooler 3/4 Transportation Gas Cooler 0,00 0,00 66,04 496,15 93,00 0,00 271,33 -59,66 2,99 0,00 -2,59 0,00 0,00 33,73
235 Gas Cooler 3/4, distrib. pipe 1 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 288,20 -60,19 4,01 0,00 -8,04 0,00 0,00 24,61
236 Gas Cooler 3/4, distrib. pipe 2 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 287,29 -60,16 4,00 0,00 -8,02 0,00 0,00 24,65
237 Gas Cooler 3/4, distrib. pipe 3 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 286,37 -60,13 4,00 0,00 -8,00 0,00 0,00 24,70
238 Gas Cooler 3/4, distrib. pipe 4 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 285,25 -60,10 3,99 0,00 -7,97 0,00 0,00 24,75
239 Gas Cooler 3/4, distrib. pipe 5 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 284,34 -60,07 3,98 0,00 -7,95 0,00 0,00 24,80
240 Gas Cooler 3/4, distrib. pipe 6 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 283,43 -60,04 3,98 0,00 -7,92 0,00 0,00 24,85
241 Gas Cooler 3/4, distrib. pipe 7 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 282,33 -60,01 3,97 0,00 -7,89 0,00 0,00 24,90
242 Gas Cooler 3/4, distrib. pipe 8 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 281,42 -59,98 3,97 0,00 -7,87 0,00 0,00 24,95
243 Gas Cooler 3/4, distrib. pipe 9 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 280,51 -59,95 3,97 0,00 -7,85 0,00 0,00 25,00
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.88 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
244 Gas Cooler 3/4, distrib. pipe 10 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 279,38 -59,92 3,96 0,00 -7,82 0,00 0,00 25,05
245 Gas Cooler 3/4, distrib. pipe 11 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 278,48 -59,89 3,96 0,00 -7,79 0,00 0,00 25,10
246 Gas Cooler 3/4, distrib. pipe 12 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 277,56 -59,86 3,95 0,00 -7,77 0,00 0,00 25,15
247 Gas Cooler 3/4, distrib. pipe 13 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 276,46 -59,82 3,95 0,00 -7,74 0,00 0,00 25,21
248 Gas Cooler 3/4, distrib. pipe 14 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 275,55 -59,80 3,94 0,00 -7,72 0,00 0,00 25,25
249 Gas Cooler 3/4, distrib. pipe 15 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 274,64 -59,77 3,94 0,00 -7,70 0,00 0,00 25,30
250 Gas Cooler 3/4, distrib. pipe 16 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 273,52 -59,73 3,93 0,00 -7,67 0,00 0,00 25,36
251 Gas Cooler 3/4, distrib. pipe 17 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 272,62 -59,70 3,93 0,00 -7,64 0,00 0,00 25,41
252 Gas Cooler 3/4, distrib. pipe 18 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 271,71 -59,67 3,92 0,00 -7,62 0,00 0,00 25,46
253 Gas Cooler 3/4, distrib. pipe 19 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 270,58 -59,64 3,92 0,00 -7,59 0,00 0,00 25,52
254 Gas Cooler 3/4, distrib. pipe 20 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 269,68 -59,61 3,91 0,00 -7,57 0,00 0,00 25,56
255 Gas Cooler 3/4, distrib. pipe 21 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 268,77 -59,58 3,91 0,00 -7,54 0,00 0,00 25,61
256 Gas Cooler 3/4, distrib. pipe 22 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 267,68 -59,54 3,90 0,00 -7,51 0,00 0,00 25,67
257 Gas Cooler 3/4, distrib. pipe 23 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 266,77 -59,51 3,90 0,00 -7,49 0,00 0,00 25,72
258 Gas Cooler 3/4, distrib. pipe 24 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 265,87 -59,49 3,89 0,00 -7,47 0,00 0,00 25,77
259 Gas Cooler 3/4, distrib. pipe 25 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 264,75 -59,45 3,89 0,00 -7,44 0,00 0,00 25,83
260 Gas Cooler 3/4, distrib. pipe 26 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 263,85 -59,42 3,88 0,00 -7,42 0,00 0,00 25,88
261 Gas Cooler 3/4, distrib. pipe 27 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 262,94 -59,39 3,88 0,00 -7,39 0,00 0,00 25,92
262 Gas Cooler 3/4, distrib. pipe 28 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 261,85 -59,35 3,87 0,00 -7,36 0,00 0,00 25,98
263 Gas Cooler 3/4, distrib. pipe 29 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 260,95 -59,32 3,87 0,00 -7,34 0,00 0,00 26,03
264 Gas Cooler 3/4, distrib. pipe 30 Transportation Gas Cooler 0,00 0,00 79,00 9,61 88,83 0,00 260,05 -59,29 3,86 0,00 -7,32 0,00 0,00 26,08
232 Gas Cooler 3/4, gas flow noise Transportation Gas Cooler 0,00 0,00 66,04 496,10 93,00 0,00 271,33 -59,66 2,99 0,00 -2,59 0,00 0,00 33,73
230 Header Discharge side Transportation Gas Cooler 0,00 0,00 78,00 90,45 97,56 0,00 341,55 -61,66 4,93 0,00 -1,77 0,00 0,00 39,06
28 Control valve (enclosed) Unit 1 0,00 0,00 87,00 87,00 3,01 360,34 -62,13 -4,60 0,00 -1,46 0,00 0,00 21,82
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.89 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
23 Exhaust Stack Opening Unit 1 0,00 0,00 84,97 2,01 88,00 0,00 380,91 -62,61 2,99 -3,58 -1,26 0,00 0,00 23,54
24 Exhaust duct outsde compressor Unit 1 0,00 0,00 76,40 12,10 87,23 0,00 376,89 -62,52 5,04 - -0,34 0,00 0,00 14,96
1 Oil Cooler Unit 1 0,00 0,00 78,11 24,50 92,00 0,00 383,45 -62,67 4,58 - -0,70 0,00 0,00 14,49
25 Piping suction side Unit 1 0,00 0,00 78,00 34,38 93,36 0,00 361,41 -62,15 4,99 0,00 -1,85 0,64 0,00 34,99
26 Piping, discharge side Unit 1 0,00 0,00 80,00 30,25 94,81 0,00 347,74 -61,82 4,95 0,00 -1,80 0,85 0,00 37,00
58 Control valve (eingehaust) Unit 3 0,00 0,00 87,00 87,00 3,01 291,64 -60,29 -4,55 0,00 -1,18 2,45 0,00 26,43
31 Exhaust Stack Opening Unit 3 0,00 0,00 84,97 2,01 88,00 0,00 312,99 -60,90 2,99 -3,59 -1,09 0,00 0,00 25,40
53 Exhaust duct outsde compressor Unit 3 0,00 0,00 79,40 6,06 87,23 0,00 309,03 -60,79 4,83 - -0,30 0,00 0,00 17,08
30 Oil Cooler Unit 3 0,00 0,00 78,11 24,50 92,00 0,00 316,11 -60,99 4,28 - -0,58 16,33 0,00 32,86
54 Piping suction side Unit 3 0,00 0,00 78,00 34,38 93,36 0,00 292,06 -60,30 4,76 0,00 -1,57 1,18 0,00 37,42
55 Piping, discharge side Unit 3 0,00 0,00 80,00 30,25 94,81 0,00 278,62 -59,89 4,70 0,00 -1,51 1,12 0,00 39,22
87 Control valve (eingehaust) Unit 4 0,00 0,00 87,00 87,00 3,01 274,47 -59,76 -4,54 0,00 -1,11 2,44 0,00 27,04
60 Exhaust Stack Opening Unit 4 0,00 0,00 84,97 2,01 88,00 0,00 267,31 -59,53 2,99 -3,61 -0,97 0,00 0,00 26,88
82 Exhaust duct outsde compressor Unit 4 0,00 0,00 79,58 5,82 87,23 0,00 269,84 -59,61 4,66 0,00 -2,15 2,47 0,00 32,59
59 Oil Cooler Unit 4 0,00 0,00 78,11 24,50 92,00 0,00 271,45 -59,67 4,00 -0,35 -1,02 0,03 0,00 34,99
83 Piping suction side Unit 4 0,00 0,00 78,00 34,38 93,36 0,00 274,65 -59,77 4,68 0,00 -1,50 0,74 0,00 37,51
84 Piping, discharge side Unit 4 0,00 0,00 80,00 30,25 94,81 0,00 261,29 -59,33 4,61 0,00 -1,44 0,00 0,00 38,64
116 Control valve (eingehaust) Unit 5 0,00 0,00 87,00 87,00 3,01 227,06 -58,11 -4,48 0,00 -0,92 2,40 0,00 28,90
89 Exhaust Stack Opening Unit 5 0,00 0,00 84,97 2,01 88,00 0,00 249,20 -58,92 2,99 -3,61 -0,91 0,00 0,00 27,54
111 Exhaust duct outsde compressor Unit 5 0,00 0,00 79,44 6,01 87,23 0,00 245,34 -58,79 4,53 - -0,26 0,00 0,00 19,51
88 Oil Cooler Unit 5 0,00 0,00 78,11 24,50 92,00 0,00 252,90 -59,05 3,85 - -0,45 10,71 0,00 30,28
112 Piping suction side Unit 5 0,00 0,00 78,00 34,38 93,36 0,00 223,15 -57,96 4,37 0,00 -1,27 0,88 0,00 39,39
113 Piping, discharge side Unit 5 0,00 0,00 80,00 30,25 94,81 0,00 215,36 -57,66 4,31 0,00 -1,23 0,28 0,00 40,52
330 Air compressor I, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 423,05 -63,52 -4,63 -8,21 -0,99 0,00 0,00 -4,34
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.90 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
Trans Adriatic Pipeline (TAP) AGProposed Gas Compressor Station GCS01, Alternative D, at district Central
Macedonia, GreeceFinal stage (20 billion m³ / year)
Sourc
No.
Source Group Li
dB(A)
R'w
dB
Lw'
dB(A)
l or S
m,m²
Lw
dB(A)
Ko
dB
s
m
Adiv
dB
Agr
dB
Abar
dB
Aatm
dB
dLrefl
dB
Cmet Lr,i
dB(A)
331 Air compressor II, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 421,36 -63,49 -4,63 -7,83 -0,98 0,00 0,00 -3,92
332 Air compressor III, air intake Utility Building 0,00 0,00 67,00 67,00 6,01 419,69 -63,45 -4,63 -6,47 -0,98 0,00 0,00 -2,52
320 Air compressor room, ventilation Utility Building 0,00 0,00 68,00 68,00 3,01 429,17 -63,64 -4,35 -5,29 -1,00 0,00 0,00 -3,27
354 Air condition unit I Utility Building 0,00 0,00 87,00 87,00 0,00 431,35 -63,69 4,73 - -0,83 6,56 0,00 12,52
353 Air condition unit II Utility Building 0,00 0,00 87,00 87,00 0,00 431,97 -63,70 4,73 - -0,83 6,54 0,00 12,50
333 Boiler room, ventilation intake Utility Building 0,00 0,00 72,00 72,00 6,01 389,96 -62,81 -4,62 -4,62 -0,91 0,00 0,00 5,05
326 Boiler room, ventilation outlet Utility Building 0,00 0,00 72,00 72,00 6,01 428,48 -63,63 -4,57 - -1,00 0,00 0,00 -9,72
321 Boiler, stack opening I Utility Building 0,00 0,00 78,00 78,00 3,01 392,39 -62,87 -4,30 -5,40 -0,92 0,00 0,00 7,53
323 Boiler, stack opening III Utility Building 0,00 0,00 78,00 78,00 3,01 395,99 -62,95 -4,31 -5,72 -0,92 0,00 0,00 7,12
322 Boiler, stack opening Ii Utility Building 0,00 0,00 78,00 78,00 3,01 394,18 -62,91 -4,30 -5,60 -0,92 0,00 0,00 7,28
318 Facade E Utility Building 87,43 37,00 37,28 117,45 57,98 3,00 392,25 -62,86 4,54 - -1,56 0,00 0,00 -11,58
324 Facade N Utility Building 87,43 37,00 37,28 390,90 63,20 3,00 413,24 -63,32 4,56 - -1,94 0,00 0,00 -17,31
325 Facade N, doors Utility Building 87,43 30,00 51,96 22,00 65,38 3,00 416,16 -63,38 5,30 - -6,60 0,00 0,00 -20,75
328 Facade S Utility Building 87,43 37,00 37,28 392,52 63,22 3,00 407,43 -63,19 4,57 -7,16 -1,86 0,00 0,00 -1,43
329 Facade S, doors Utility Building 87,43 30,00 51,96 22,00 65,38 3,00 405,47 -63,15 5,28 - -5,03 0,00 0,00 -4,91
327 Facade W Utility Building 87,43 37,00 37,28 115,70 57,92 3,00 429,88 -63,66 4,66 - -2,03 0,00 0,00 -23,12
319 Roof Utility Building 87,43 37,00 37,28 595,39 65,03 0,00 411,35 -63,28 3,58 - -1,64 0,00 0,00 -7,98
351 Air condition unit I Workshop/Stores Building 0,00 0,00 87,00 87,00 0,00 441,31 -63,89 4,76 - -0,79 0,00 0,00 14,56
352 Air condition unit II Workshop/Stores Building 0,00 0,00 87,00 87,00 0,00 438,43 -63,83 4,75 - -0,78 0,00 0,00 14,94
Werner Genest + PartnerIngenieurgesellschaft mbH
Attachment 3.91 GCS01-WGP-000-S-TRS-0002
127D5, Rev. 00
SoundPLAN 7.1
25
25
25
25
25
25
2525
25
25
25
25
25
25
30
30
30
30
30
30
30
30
30
30
35
35
35
3535
35
35
40
40
40
40
45
45
45
50
50
55
55
60
65
2 Konstantinato
1 Krinos
3 Neochori
6 Station Fence East
5 Station Fence South
4 Station Fence West
34713500
34713500
34714000
34714000
34714500
34714500
34715000
34715000
34715500
34715500
34716000
34716000
34716500
34716500
34717000
34717000
34717500
34717500
34718000
34718000
34718500
34718500
34719000
34719000
4543000
4543000
4543500
4543500
4544000
4544000
4544500
4544500
4545000
4545000
4545500
4545500
4546000
4546000
4546500
4546500
4547000
4547000
4547500
4547500
Attachment 4
GCS01-WGP-000-S-TRS-0002
127D5 G1, Rev. 00
Trans Adriatic Pipeline AG
Proposed Gas Compression Station
GCS01, district Central Macedonia, Greece
Alternative D
Noise Contour Map
Final stage (20 billion m³ / year)
Temperature 15 °C
Relative Humidity 65 %
Map Source:
Google Earth
-----------------------------------------------------------
Noise Propagation Outdoor
according to ISO 9613-2
Calculation Parameter:
T = 15°C, Humidity 65%, Air pressure 1015 mbar
Cmet = 0 dB
Wind 2 m/s toward receptor
Ground effect on proposed GCS00: fully reflective, G=0
Ground effect around: Agricultural area, G=0,85
Limits for attenuation by screening:
Single sound screen 20 dB
Multiple sound screens 25 dB
Calculation Grid 50 m
Height of noise contours 2 m above ground
Legend
Receptor
Industry building
noise source (point)
noise source (line)
noise source (area)
Noise Level
LAeq
= 25 dB(A)
= 30 dB(A)
= 35 dB(A)
= 40 dB(A)
= 45 dB(A)
= 50 dB(A)
= 55 dB(A)
= 60 dB(A)
= 65 dB(A)
= 70 dB(A)
= 75 dB(A)
Scale (on paper size A3) 1:20000
00 100 200 400 600 800 1000m
Date 06/2013