RIGOL TECHNOLOGIES, INC. DSA800 series is one of RIGOL's compact size, light weighteconomic spectrum analyzers, the digital IF technology guarantees its reliability and performance to meet the most demanding RF applications. No.1 DSA800 LEADING PROGRAMMING AND MEASUREMENT SOLUTIONS Batronix • All-Digital IF Technology • 9 kHz - 1.5 GHz Frequency Range • Up to -135dBm Displayed Average Noise Level (DANL) • -80dBc/Hz @ 10kHz Oset Phase Noise • Total Amplitude Uncertainty < 1.5dB • 100Hz Minimum Resolution Bandwidth (RBW) • 1.5GHz Tracking Generator (DSA815-TG) • Advanced Measurement functions (Option) • EMI Filter & Quasi-Peak Detector Kit(Option) • VSWR Measurement Kit(Option) • Complete Connectivity: LAN,USB host,USB device,GPIB (option) • 8 Inch WVGA (800x480) Display • Compact Size,Light weight design

Transcript of No - Ham Radio Blog PD0AC · PDF file• FilterEMI & Quasi-Peak Detector Kit(Option) •...

RIGOL TECHNOLOGIES, INC.

DSA800 series is one of RIGOL's compact size, light weighteconomic spectrum analyzers, the digital IF technologyguarantees its reliability and performance to meet the mostdemanding RF applications.

• All-Digital IF Technology• 9 kHz - 1.5 GHz Frequency Range• Up to -135dBm Displayed Average Noise Level (DANL)• -80dBc/Hz @ 10kHz Oset Phase Noise• Total Amplitude Uncertainty < 1.5dB• 100Hz Minimum Resolution Bandwidth (RBW)• 1.5GHz Tracking Generator (DSA815-TG)• Advanced Measurement functions (Option)• EMI Filter & Quasi-Peak Detector Kit(Option)• VSWR Measurement Kit(Option)• Complete Connectivity: LAN,USB host,USB device,GPIB (option)• 8 Inch WVGA (800x480) Display• Compact Size,Light weight design

No.1

DSA800

LEADING PROGRAMMING AND MEASUREMENT SOLUTIONS Batronix

• All-Digital IF Technology• 9 kHz - 1.5 GHz Frequency Range• Up to -135dBm Displayed Average Noise Level (DANL)• -80dBc/Hz @ 10kHz Oset Phase Noise• Total Amplitude Uncertainty < 1.5dB• 100Hz Minimum Resolution Bandwidth (RBW)• 1.5GHz Tracking Generator (DSA815-TG)• Advanced Measurement functions (Option)• EMI Filter & Quasi-Peak Detector Kit(Option)• VSWR Measurement Kit(Option)• Complete Connectivity: LAN,USB host,USB device,GPIB (option)• 8 Inch WVGA (800x480) Display• Compact Size,Light weight design

1 RIGOL

Unique widescreen display, friendly interface and easy-to-use operations

Product Dimensions: Width X Height X Depth = 361.6 mm x 178.8 mm x 128 mm Weight:4.25kg(9.4lbs)

Benefits of Rigol's all digital IF design

1.Theabilitytomeasuresmallersignals:onthebasisofthistechnology,theIFfilterenablessmallerbandwidthsettings,whichgreatlyreducethedisplayedaveragenoiselevel.

2.Theabilitytodistinguishbetweensmallsignalsbyfrequency:usingtheIFfilterwiththesmallestbandwidthsettingitispossibletomakeoutsignalswithafrequencydifferenceofonly100Hz.

3.Highprecisionamplitudereadings:thistechnologyalmosteliminatestheerrorsgeneratedbyfilterswitching,referenceleveluncertainty,scaledistortion,as well as errors produced in the process of switching between logarithmic and linear display of amplitude when using a traditional analog IF design.

4.Higherreliability:comparedwithtraditionalanalogdesigns,thedigitalIFgreatlyreducesthecomplexityofthehardware,thesysteminstabilitycausedbychannelaging,andthetemperaturesensitivitythatcancontributetopartsfailure.

5.Highmeasurementspeed:theuseofdigitalIFtechnologyimprovesthebandwidthprecisionandselectivityofthefilter,minimizingthescanningtimeandimprovingthespeedofthemeasurement.

RIGOL 2

Distinguish the two nearby signals clearly with the 100Hz RBW

Compare the spectrums when change the RBW settings with different color trace

Zero span to demodulate the AM signal

Measure lower than -130dBm signal with the standard Preamplifier

EMI Measurement (EMI Filter & Quasi-Peak & Pass_Fail)

The GUI to control the RF Demo Kit (Transmitter) directly

VSWR Measureasurement

Readout the Spectrum Peak values with the Peak table function

Features and Benefits

MarkerFrequencyCounterResolutionUncertainty

1Hz,10Hz,100Hz,1KHz,10KHz,100KHz±(frequency indicat ion × frequency referenceuncertainty+counterresolution)

Note:FrequencyReferenceUncertainty=(agingrate×periodsinceadjustment+temperaturedrift).

Specifications

BandwidthsResolutionBandwidth(-3dB)ResolutionBandwidth(-6dB)RBWUncertaintyResolution Filter Shape Factor (60dB:3dB)VideoBandwidth(-3dB)

100Hzto1MHz,in1-3-10sequence200Hz,9kHz,120kHz<5%,nominal<5,nominal

1Hzto3MHz,in1-3-10sequence

Opt

FrequencySpanRangeUncertaintySSBPhaseNoiseCarrier Offset 10kHzoffset

0Hz,100Hzto1.5GHz±span/(sweeppoints-1)

<-80dBc/Hz

DSA815

3 RIGOL

Specificationsarevalidafter30minutewarmuptimewithavalidcalibration.

Typicalvalueandnominalvaluearedefinedasfollows.• Typicalvalue:definedasthespecificationswhentheproductisunderspecifiedconditions.• Nominalvalue:definedastheapproximatequantityintheapplicationoftheproduct.

FrequencyFrequencyRangeFrequencyResolutionInternalFrequencyReferenceReferenceFrequencyAging RateTemperature StabilityFrequencyReadoutAccuracyMarkerResolutionMarkerUncertainty

20℃to30℃

9kHzto1.5GHz1Hz

10MHz<2ppm/year<2ppm

span/(sweeppoints-1)±(frequency indication × frequency referenceuncertainty + 1% × span + 10% × resolut ionbandwidth+markerresolution)

DSA815

Frequency

RF Demo Kit(TX1000)

Tracking Generator(DSA815-TG)

DSA Accessories Package (DSA Utility Kit)

VSWR Bridge (VB1020/VB1030)

DSA PC Software(Ultra Spectrum)

Advanced Measurement Kit(DSA800-AMK)

USB to GPIB Interface Converter for Instrument

(USB-GPIB)

Rack Mount Kit(DSA800-RMSA)

LevelDisplayLogarithmicLevelAxisLinearLevelAxisNumberofDisplayPointsNumber of TracesTrace Detectors

Trace Functions

UnitsofLevelAxis

1dBto200dB0toReferenceLevel6013+MathTraceNormal,Positive-peak,Negative-peak,Sample,RMS,VoltageAverage,Quasi-peakC lea r Wr i t e , Max Ho ld , M in Ho ld , Ave rage ,View,BlankdBm,dBmV,dBμV,nV,μV,mV,V,nW,μW,mW,W

10dBRFattenuation,relativeto50MHz,20ºCto30ºCFrequencyResponse

FrequencyResponse(PreamplifierOff)FrequencyResponse(PreamplifierOn)

<0.7dB

<1.0dB

100kHzto1.5GHz

1MHzto1.5GHz

RBWSwitchingUncertaintyUncertainty 100Hz to1MHz, relative to1 kHz

RBW<0.1dB

RFattenuation=30dB50V+20dBm(100mW)+30dBm(1W)

DisplayedAverageNoiseLevel(DANL)0dBRFAttenuation,RBW=VBW=100Hz,SampleDetector,TraceAverage≥50DANL(PreamplifierOff)

DANL(PreamplifierOn)

100kHzto1MHz

1MHzto1.5GHz

100kHzto1MHz

1MHzto1.5GHz

<-90dBm,typ.-110dBm<-110dBm+6x(f/1GHz)dB,typ.-115dBm<-110dBmtyp.-130dBm<-130dBm+6x(f/1GHz)dB,typ.-135dBm

MeasurementRangeRangeMaximumratedinputlevelDCVoltageCWRFPowerMax.DamageLevel

DANLto+20dBm

fc=50MHz,relativeto10dB,20ºCto30ºC

0to30dB,in1dBstep<0.5dB

ReferenceLevelRangeResolution Log Scale

Linear Scale

-100dBmto+20dBm,in1dBstep0.01dB4digits

fc=50MHz,peakdetector,preamplifieroff,10dBRFattenuation,inputsignal=-10dBm,20ºCto30ºC

±0.4dB

RIGOL 4

InputAttenuationSwitchingUncertaintySetting RangeSwitchingUncertainty

AbsoluteAmplitudeUncertaintyUncertainty

LevelMeasurementUncertaintyLevelMeasurementUncertainty 95%confidencelevel,S/N>20dB,

RBW=VBW=1kHz,preamplifieroff,10dBRFattenuation,

<1.5dB,nominal

Amplitude

Note:Wheninputlevel>+25dBm,theprotectionswitchwillbeon.

10MHzto1.5GHz

Sweep

RF InputImpedance Connector

TG outImpedance Connector

TG OutputFrequencyRangeOutputLevelOutput Flatness

Sweep Time Range

SweepTimeUncertainty

SweepMode

TriggerTrigger SourceExternalTriggerLevel

1MHzto1.5GHz,referencedto50MHz

100Hz≤Span≤1.5GHzSpan=0Hz100Hz≤Span≤1.5GHzSpan=0Hz

50ΩN female

50ΩN female

9kHzto1.5GHz-20dBmto0dBm,in1dBsteps±3dB

10msto1500s20μsto1500s5%,nominal0.5%,nominalContinuous, single

Freerun,Video,External5VTTLlevel

10MHzREFIn/10MHzREFOut/ExternalTriggerInConnector 10MHzREFInAmplitude10MHzREFOutAmplitudeTriggerVoltage

BNCfemale0dBmto+10dBm+3dBmto+10dBm5VTTLlevel

5 RIGOL

RFInputVSWR10dBRFAttenuationVSWR 1MHzto1.5GHz <1.5

Intermodulation

1dBGainCompression

Spurious ResponsesImageFrequencyIntermediateFrequencySpurious Response, InherentSpurious Response, Others

Input Related Spurious

SecondHarmonicIntercept(SHI)Third-orderIntermodulation(TOI)

TotalPoweratInputMixer

fc>30MHz

fc≥50MHz,preamplifieroff

Referenced to loca l osc i l l a to rs , r e f e r enced t o A /D conve r s i o n ,referenced to subharmonic of first LO, referencedtoharmonicoffirstLOMixerlevel:-30dBm

+40dBm+10dBm

>0dBm

<-60dBc<-60dBc<-88dBm,typ.<-60dBc

<-60dBc,typ.

-50dBm<referencelevel<0,10MHz<fc<1.5GHz,20ºCto30ºC

Note: Mixer power level (dBm) = input power (dBm) – input attenuation (dB).

Sweep

Trigger Functions

Tracking Generator (DSA815-TG)

Inputs and Outputs

DisplayTypeResolutionSizeColors

PrinterSupportedProtocol

USB

ConnectorProtocol

ConnectorProtocol

TFT LCD800x480pixels8 inch64k

PictBridge

USBHostBplugVersion2.0

A plugVersion2.0

USBDevice

Remote ControlUSBLAN Interface

IEC/IEEEBus(GPIB)

PowerSupplyInputVoltageRange,ACACSupplyFrequencyPowerConsumption

Mass MemoryMass Memory

withopt.USB-GPIB

USBTMC10/100Base-T,RJ-45,LXI Class CIEEE488.2

100V-240V,nominal45Hz-440Hz,35Wtyp.Max50Wwithalloptions.

FlashDisk(internal),USBDisk(notsupplied)

TemperatureOperating temperature rangeStorage temperature range

Weight

Dimensions

WithTG

(WxHxD)

5ºCto40ºC-20ºCto70ºC

4.25kg(9.4lbs)

361.6mmx178.8mmx128mm(14.2inches×7.0inches×5.0inches)

RIGOL 6

General Specifications

DescriptionSpectrum Analyzer, 9 kHz to 1.5 GHz (with Spec t rum Ana lyzer, 9 kHz to 1 .5 GHz, w i th p reampl i f i e r, w i th track generator, installed before leaving factory

Order NumberDSA815DSA815-TG

QGD03X00--DSA800-EMIDSA800-VSWRVB1020VB1030Ultra SpectrumDSA800-AMKTX1000USB-GPIBDSA800-RMSA

DSA Utility Kit

QGD03X00UGD03000UGD03100PGD03000PGD03100

Mode

StandardAccessories

Options

Optional Accessories

Orderable Manuals(Hard Copy)

Ordering Information

RIGOL® is the registered trademark of RIGOL Technologies, Inc. Product information in this document subject to update without notice. For the latest information about RIGOL's products, applications and services, please contact local RIGOL or access RIGOL website: www.rigol.com

Headquarter RIGOL TECHNOLOGIES, INC.No.156,Cai He Village,Sha He Town,Chang Ping District, Beijing,102206 P.R.ChinaTel:+86-10-80706688Fax:+86-10-80705070Email: [email protected]

USARIGOL TECHNOLOGIES,USA INC.7401 First Place, Suite NOakwood VillageOH 44164, USAToll free: 1-877-4-RIGOL-1Tel: (440) 232-4488Fax: (216)-754-8107Email: beyondmeasure@ rigoltech.com

EuropeRIGOL TECHNOLOGIES EU, GmbHLindbergh str. 482178 Puchheim, GermanyTel: +49(0)89-8941895-0Email: info-europe@ rigoltech.com

May,2012

Quick Guide (Hard Copy)CDROM (User’s Guide, Programming Guide)Power CableEMI Filter & Quasi-Peak Detector Kit (DSA815 only)VSWR Measure Kit (DSA815 only)VSWR Bridge (2 GHz)VSWR Bridge (3 GHz)DSA PC SoftwareAdvanced Measurement KitRF Demo Kit (Transmitter)USB to GPIB Interface Converter for InstrumentRack Mount KitDSA Accessories Package Including: N-SMA Cable, BNC-BNC Cable, N-BNC Adapter, N-SMA Adapter, 75Ω-50Ω Adapter, Antenna 2 (900MHz/1.8GHz), Antenna 2 (2.4GHz)Quick Guide, Chinese& EnglishUser’s Guide, ChineseUser’s Guide, EnglishProgramming Guide, ChineseProgramming Guide, English

Batronixwww.batronix.comLise-Meitner-Str. 1-724223 Schwentinental, Germany