Uses
Recommended primer for Fosroc cementitious repairsystem. For improving and bonding floor toppings, rendersand mortars; repair of worn, damaged or spalled concrete;polymer modified floor screeds.
Advantages
Simply brush onto concrete as a primer. Single component,gauged as required.
High adhesion -Provides excellent bond to concrete,masonry, stone work plaster and block board.
Increased strength - Improves tensile and flexuralproperties of mortar. Allows thin section applications.
Versatile - Compatible with all commonhydraulic cements
Economical - Economical to use
Description
Nitobond AR is a modified acrylic emulsion speciallydesigned for use as a bonding aid and gauging liquid forcementitious systems. It is resistant to hydrolysis and cantherefore be used for external applications.
Nitobond AR is the recommended primer for the Fosroccementitious repair system.
Technical support
Fosroc offers a technical support service to specifiers, endusers and contractors, as well as on-site technical assistancein locations all over the country.
Properties
Mechanical properties
Typical improvements in mechanical properties of a 3 : 1cement mortar /sand using Nitobond AR.
Mechanical properties Curing Control Nitobond AR conditions
Adhesion to concrete Dry 5.0 20.0Slant shear strengthN/mm2 ( BS 6319)
Specification clauses
As a bonding agent
The bonding agent shall be Nitobond AR an acrylic basedemulsified solution containing a minimum of 43% solids andcompatible with cementitious materials. The bonding agentshall provide adequate bond strength when directly appliedon concrete and also mixed with neat cement.
As a mortar modifier
The mortar modifier shall be Nitobond AR, an acrylic emulsifiedcement modifier which provides good bond with concrete /masonry and improves the flexural strength, tensile strengthproperties of the mortar when added in the specified quantities.It shall be compatible with all common hydraulic cements.
Application instructions
Surface Preparation
The object of the surface preparation is to achieve a cleansound surface with a good mechanical key. All substratesshould be cleaned and free of dust, plaster, oil, paint, grease,corrosion deposits, and any other deleterious substances.Laitence should be removed by mechanical means. Oil orgreasy deposits should be removed by suitable means. Allsurfaces so treated should be thoroughly washed with cleanwater. Smooth substrates must be mechanically roughenede.g. by scabbling, needle gun or grit/ sand blasting to providea mechanical key.
Concrete repairs : Remove all surface dust and debris. Anyreinforcing steel in the repair area should be exposed aroundits full circumference and cleaned to remove all loose scaleand corrosion deposits and then primed with Nitozinc Primer.
Priming
Immediately before priming, the concrete substrate shouldbe thoroughly dampened with water and any excess beingbrushed off. Scrub Nitobond AR into the substrate. Avoidpudding of the emulsion. The repair mortar/topping shouldbe applied whilst the primer is still tacky. The bond coatbecomes tacky in about 2 minutes and best results areachieved if the mortar is applied within the next 5-10 min
In case of Nitobond AR slurry coat (1 volume of Ntiobond AR +1.5 volume of water + 1.5 volume of cement), best results areachieved, if mortar is applied within 5 minutes of applicationof bond coat.
Nitobond® AR
Typical Mix designs to modify mortars :
OPC 50 kg
Zone 2 sand 150 kg
Nitobond AR 8 - 10 litres
Water Add sufficient water togive required consistency
Note : Trials are recommended to optimise mix designs. 1:4cement sand mortars can also be used with same dosage ofNitobond AR.
General recommendations
For repairs
Prepare surfaces thoroughly as previously recommended Cutback edges to avoid feather edging. Prime all surfacesincluding edges, using Nitobond AR.
All applications shall be wet on wet. For best results NitobondAR should be allowed to become tacky. If the bonding agent isallowed to dry for more than 15 minutes at 300 C initial 'grab' tothe repair mortar will be reduced. Therefore, the use oftemporary shuttering is recommended. Water content of themortar should be kept to the minimum necessary.
For consistent results, the use of clean, dry sand isrecommended. Where the use of wet sand is unavoidable,the quantity of water to be added must be reduced.
Cure mortars using Nitobond AR to prevent rapid drying out.
Protect uncured mortar from frost and rain. Do not retempermortar after initial set.
Minimum application temperature for Nitobond AR is 100C,but the mortar should not be applied if the temperature isexpected to fall.
For permanently immersed conditions consult Local Fosrocoffice.
Limitations
As a bonding agent
Nitobond AR may exhibit less overlay time at highertemperature. In such cases as overlay mortar shall not beapplied when Nitobond AR is totally dry.
Nitobond AR when used as bonding agent cannot act as abarrier coat against ingress of chloride ions from the substrate.
Equipment cleaning
Immediately after use, wash all tools with clean water.
Estimating
Packaging
Nitobond AR is supplied in 1, 5 and 20 litre plastic containers.
Coverage
Approximately 6 - 8m2/ litre depending on substrate
Storage
Shelf life
6 months at 300C. Nitobond AR should be protected from frost.
Nitobond® AR
Precautions
Health & Safety instructions
Nitobond AR is non toxic. However it should never be ingestedand if it comes in contact with eyes, wash immediately withplenty of water and seek medical treatment.
Nitobond AR is slightly alkaline. Skin contact should beavoided. Gloves and protective clothing should be wornduring application.
Fire
Nitobond AR is non flammable.
Flash point : 480C
Additional information
Nitobond AR forms a part of the Fosroc concrete repair system.
Fosroc manufactures a wide range of products specificallydesigned for repair and refurbishment of damaged reinforcedconcrete. This includes hand-placed and spray grade repairmortars, fluid micro concretes, chemical resistant epoxymortars and a comprehensive package of protective coatings.In addition, a wide range of complementary products isavailable. This includes joint sealants, water proofingmembranes, grouting, anchoring and specialised flooringmaterials.
Nitobond® AR
INDIA/0903/B
Important note :Fosroc products are guaranteed against defective materials and manufacture and are sold subjectto its standard terms and conditions of sale, copies of which may be obtained on request. WhilstFosroc endeavours to ensure that any advice, recommendation specification or information it maygive is accurate and correct, it cannot, because it has no direct or continuous control over whereor how its products are applied, accept any liability either directly or indirectly arising from theuse of its products whether or not in accordance with any advice, specification, recommendationor information given by it.
telephone fax e-mail
++91 80-2334 3188 ++91 80-2334 3178 [email protected]
Fosroc Chemicals (India) Pvt. Ltd.Head Office‘Vishnu Chittam’, No. 10, 2nd FloorSirur Park B Street, SeshadripuramBangalore 560020www.fosroc.com
® Denotes the trademark of Fosroc International Limited
Regional OfficesBangalore Mumbai Delhi Kolkata‘Vishnu Chittam’, No.10, 1stFloor 208/209, Persepolis 109-113, 1st Floor, Vikrant Towers P-569, Lake Terrace Extn.Sirur Park B Street, Seshadripuram Sector 17, Vashi 4, Rajendra Place First FloorBangalore 560 020 Navi Mumbai 400 703 New Delhi 110 008 Kolkata 700 029Ph:080-2334 3188 Ph:022-2789 6411/12 Ph:011- 45062000-5 Ph: 033 24650917 / 55343188Fax : 080-23368667 Fax: 022 - 2789 6413 Fax: 011- 45062001 Fax: 033-24650891email: [email protected] email:[email protected] email:[email protected] email:[email protected]
Ahmedabad : (079) 26762799 Ankleshwar :(02646) 220704/224687 Bellary: 09845891690 Bhubaneshwar : (0674) 2521176 Chennai : (044) 24899949/24853383 Chandigarh : (0172) 2639360 Cochin : (0484) 2347465 Coimbatore : (0422) 2472966 Goa : (0832) 09423058696 Guwahati : (0361) 2462866 Hyderabad : (040) 27662324/27662425 Indore : (0731) 4049339 Jaipur : (0141) 2336103 Lucknow :(0522) 2239044 Nagpur: (0712) 2753510/2563242 Visakhapatnam : (0891) 2564850 / 2707607
Nito
bond
® A
R(M
)
constructive solutionsNitobond® AR(M)
Acrylic emulsion cement modifier and water basedconcrete bonding agent
Uses
Recommended primer for Fosroc cementitious repairsystem. For improving and bonding floor toppings, rendersand mortars; repair of worn, damaged or spalled concrete;polymer modified floor screeds.
Advantages
Simply brush onto concrete as a primer. Single component,gauged as required.
High adhesion - Provides excellent bond to concrete,masonry, stone work, plaster and block board.
Increased strength - Improves tensile and flexuralproperties of mortar. Allows thin section applications.
Versatile - Compatible with all common hydrauliccements
Economical - Economical to use
Description
Nitobond AR(M) is a modified acrylic emulsion speciallydesigned for use as a bonding aid and gauging liquid forcementitious systems. It is resistant to hydrolysis and cantherefore be used for external applications.
Nitobond AR(M) is the recommended primer for the Fosroccementitious repair system.
Technical support
Fosroc offers a technical support service to specifiers, endusers and contractors, as well as on-site technical assistancein locations all over the country.
Properties
Mechanical properties
Typical improvements in mechanical properties of a 1 : 3sand/cement mortar using Nitobond AR(M)
Mechanical properties Control Nitobond AR(M)
Compressive strength(N/mm2) 25 30
Flexural strength(N/mm2) (B S 6319) 7 8
Adhesion to concreteSlant shear bondN/mm2 ( BS 6319) 5 6
Application instructions
Surface Preparation
The object of the surface preparation is to achieve a cleansound surface with a good mechanical key. All substratesshould be cleaned and free of dust, plaster, oil, paint, grease,corrosion deposits, and any other deleterious substances.Laitence should be removed by mechanical means. Oil orgreasy deposits should be removed by suitable means. Allsurfaces so treated should be thoroughly washed with cleanwater. Smooth substrates must be mechanically roughenede.g. by scabbling, needle gun or grit/ sand blasting to providean mechanical key.
Concrete repairs : Any reinforcing steel in the repair areashould be exposed around its full circumference and cleanedto remove all loose scale and corrosion deposits and thenprimed with Nitozinc Primer (M). Remove all surface dustand debris.
Priming
Immediately before priming, the concrete substrate shouldbe thoroughly dampened with water and any excess beingbrushed off. Scrub Nitobond AR(M) into the substrate. Avoidpudding of the emulsion. The repair mortar/topping shouldbe applied whilst the primer is still tacky. However a satisfactorybond can be achieved upto 15 mins. after application at 300C.
Typical Mix designs to modify mortars :
OPC 50 kg
Zone 2 sand 150 kg
Nitobond AR(M) 14 - 16 L
Water Add sufficient water to giverequired consistency
Note : Trials are recommended to optimise mix designs.
Additional Guidance
Prepare surfaces thoroughly as previously recommendedCut back edges to avoid feather edging. Prime all surfacesincluding edges, using Nitobond AR(M).
All applications shall be wet on wet. For best results NitobondAR(M) should be allowed to become tacky. If the bondingagent is allowed to dry for more than 15 minutes at 300 Cinitial 'grab' to the repair mortar will be reduced. Therefore,the use of temporary shuttering is recommended. Watercontent of the mortar should be kept to the minimumnecessary.
Nitobond® AR(M)
For consistent results, the use of clean, dry sand isrecommended. Where the use of wet sand is unavoidable,the quality of water to be added must be reduced.
Cure mortars using Nitobond AR(M) to prevent rapid dryingout.
Protect uncured mortar from frost and rain. Do not retempermortar after initial set.
Minimum application temperature for Nitobond AR(M) is 100C,but the mortar should not be applied if the temperature isexpected to fall.
For permanently immersed conditions consult Local Fosrocoffice.
Limitations
As a bonding agent
Nitobond AR(M) may exhibit less overlay time at highertemperature. In such cases as overlay mortar shall not beapplied when Nitobond AR(M) is totally dry.
Nitobond AR(M) when used as bonding agent cannot act as abarrier coat against ingress of chloride ions from the substrate.
Equipment cleaning
Immediately after use, wash all tools with clean water.
Estimating
Packaging
Nitobond AR(M) is supplied in 1, 5 and 20 litre plasticcontainers.
Coverage
Approximately 6 - 8m2/ litre depending on substrate.
Storage
Shelf life
Nitobond AR(M) has a shelf life of 12 months at 300C.Nitobond AR(M) should be protected from frost.
Precautions
Health & Safety
Nitobond AR(M) is non toxic. However it should never beingested and if it comes into contact with eyes, washimmediately with plenty of water and seek medicaltreatment.
Nitobond AR(M) is slightly alkaline. Skin contact should beavoided. Gloves and protective clothing should be worn.
Fire
Nitobond AR(M) is non flammable.
Nitobond® AR(M)
Nitobond® AR(M)
INDIA/911/B
Important note :Fosroc products are guaranteed against defective materials and manufacture and are sold subjectto its standard terms and conditions of sale, copies of which may be obtained on request. WhilstFosroc endeavours to ensure that any advice, recommendation specification or information it maygive is accurate and correct, it cannot, because it has no direct or continuous control over whereor how its products are applied, accept any liability either directly or indirectly arising from theuse of its products whether or not in accordance with any advice, specification, recommendationor information given by it.
telephone fax e-mail
++91 80-2334 3188 ++91 80-2334 3178 [email protected]
Fosroc Chemicals (India) Pvt. Ltd.Head Office‘Vishnu Chittam’, No. 10, 2nd FloorSirur Park B Street, SeshadripuramBangalore 560020www.fosroc.com
® Denotes the trademark of Fosroc International Limited
Regional OfficesBangalore Mumbai Delhi Kolkata‘Vishnu Chittam’, No.10, 1stFloor 208/209, Persepolis 109-113, 1st Floor, Vikrant Towers P-569, Lake Terrace Extn.Sirur Park B Street, Seshadripuram Sector 17, Vashi 4, Rajendra Place First FloorBangalore 560 020 Navi Mumbai 400 703 New Delhi 110 008 Kolkata 700 029Ph:080-2334 3188 Ph:022-2789 6411/12 Ph:011- 45062000-5 Ph: 033 24650917 / 55343188Fax : 080-23368667 Fax: 022 - 2789 6413 Fax: 011- 45062001 Fax: 033-24650891email: [email protected] email:[email protected] email:[email protected] email:[email protected]
Ahmedabad : (079) 26762799 Ankleshwar :(02646) 220704/224687 Bellary: 09845891690 Bhubaneshwar : (0674) 2521176 Chennai : (044) 24899949/24853383 Chandigarh : (0172) 2639360 Cochin : (0484) 2347465 Coimbatore : (0422) 2472966 Goa : (0832) 09423058696 Guwahati : (0361) 2462866 Hyderabad : (040) 27662324/27662425 Indore : (0731) 4049339 Jaipur : (0141) 2336103 Lucknow :(0522) 2239044 Nagpur: (0712) 2753510/2563242 Visakhapatnam : (0891) 2564850 / 2707607
Nito
bond
® A
R(S
pl.)
constructive solutionsNitobond® AR(Spl.)
Latex acrylic polymer based cement modifier cumbonding aid
Uses
For improving and bonding floor toppings, mortars andrenders
As a bonding agent for Renderoc and other cementitiousmortars
Polymer modified mortars and screeds for reinstatementof worn out/damaged concrete
Advantages
High adhesion - Provides excellent bond to concrete,masonry, stone work, plaster and block work.
Increased strength - Improves tensile and flexuralproperties of mortar.
Versatile - Compatible with all common hydraulic cements
User friendly - application by brush/spray
Improves cohesion - No bleeding and segregation
Description
Nitobond AR(Spl.) is a single component latex acyrlic poly-mer emulsion used as bonding aid cum cement modifier.
Technical support
Fosroc offers technical support service to specifiers, endusers and contractors, as well as on-site technicalassistance in locations all over the country.
Properties
Appearance : Milky white liquid
Solid content : Exceeds 35%
pH : 8 -9
Specific gravity : 1.04 @ 270C
Mechanical Properties* Control Nitobond AR(Spl) mortar
Compressive strength@ 28days (ASTM C109)(N/mm2 ) 18-20 24.0
Flexural strength@28 days (ASTM C348) 4.0 6.0
Adhesion to concrete(ASTM C882) (Slant shear) 3.5 5
Mix proportions:
As a cement modifier :
1 litre Nitobond AR(Spl) : 5 kg cement : 15 kgs graded quartzsand.
As a bonding agent :
0.5 part cement : 1 part Nitobond AR(Spl) by weight.
Application instructions
Surface Preparation
The object of the surface preparation is to achieve a cleansound surface with a good mechanical key. All substratesshould be cleaned and free of dust, plaster, oil, paint, grease,corrosion deposits, and any other deleterious substances.Laitence should be removed by mechanical means. Oil orgreasy deposits should be removed by suitable means. Allsurfaces so treated should be thoroughly washed with cleanwater. Smooth substrates must be mechanically roughenede.g. by scabbling, needle gun or grit/ sand blasting to providea mechanical key.
Concrete repairs : Any reinforcing steel in the repair areashould be exposed around its full circumference and cleanedto remove all loose scale and corrosion deposits and thenprimed with Nitocote AP35, acrylic primer. All surface dustand debris shall be removed.
Priming
Immediately before priming, the concrete substrate shouldbe thoroughly dampened with water and any excess beingbrushed off. Scrub Nitobond AR(Spl.)into the substrate.Puddling of the emulsion to be avoided. The repair mortar/topping should be applied whilst the primer is still tacky.However a satisfactory bond can be achieved upto 15 mins.after application at 300C.
In order to obtain a smooth consistency mortar, the cementand sand must be dry mixed and then poured into the liquidwith the required amount of water in the prescribed mixproportions.
Additional Guidance
Edges shall be cut back to avoid feather edging and allsurfaces including edges shall be primed using NitobondAR(Spl.).
Nitobond® AR(Spl.)
All applications shall be wet on wet. For best results NitobondAR(Spl.) should be allowed to become tacky. If the bondingagent is allowed to dry for more than 15 minutes at 300 Cinitial 'grab' to the repair mortar will be reduced. Therefore,the use of temporary shuttering is recommended. Watercontent of the mortar should be kept to the minimumnecessary.
For consistent results, the use of clean, dry sand isrecommended. Where the use of wet sand is unavoidable,the quantity of water to be added must be reduced.
Mortars shall be cured using Nitobond AR(Spl.) to preventrapid drying out. Uncured mortar shall be protected from frostand rain. Mortar shall not be retampered after initial set.
Minimum application temperature for Nitobond AR(Spl.) is100C, but the mortar should not be applied if the temperatureis expected to fall.
For permanently immersed conditions local Fosroc officeshall be consulted.
Limitations
As a bonding agent
Nitobond AR(Spl.) may exhibit less overlay time at highertemperature. In such cases, overlay mortar shall not beapplied when Nitobond AR(Spl.) is totally dry.
Nitobond AR(Spl.) when used as bonding agent cannot actas a barrier coat against ingress of chloride ions from thesubstrate.
Equipment cleaning
Immediately after use, wash all tools with clean water.
Estimating
Packaging
Nitobond AR(Spl.) is supplied in 1, 5 and 20 litre plasticcontainers.
Coverage
As a cement modifier
Approximately 6 - 8m2/ litre depending on substrate. 21kg ofmixed polymer mortar (1 part polymer, 5 parts cement & 15parts quartz sand) will yield approximately 10 -11 litres.
As a bonding agentApproximately 3 - 4 m2/litre* depending on substrate condi-tions. (* 0.5 part cement : 1 part of Nitobond AR (Spl) byweight.
Storage
Shelf lifeNitobond AR(Spl.) has a shelf life of 12 months at 300C.Nitobond AR(Spl.) should be protected from frost.
Nitobond® AR(Spl.)
Precautions
Health & Safety instructions
Nitobond AR(Spl.) is non toxic. However it should never beingested and if it comes into contact with eyes, it shall bewashed immediately with plenty of water and medicaltreatment shall be sought immediately.
Nitobond AR(Spl.) is slightly alkaline. Skin contact should beavoided. Gloves and protective clothing should be worn.
Fire
Nitobond AR(Spl.) is non flammable.
Nitobond® AR(Spl.)
INDIA/0918/D
Important note :Fosroc products are guaranteed against defective materials and manufacture and are sold subjectto its standard terms and conditions of sale, copies of which may be obtained on request. WhilstFosroc endeavours to ensure that any advice, recommendation specification or information it maygive is accurate and correct, it cannot, because it has no direct or continuous control over whereor how its products are applied, accept any liability either directly or indirectly arising from theuse of its products whether or not in accordance with any advice, specification, recommendationor information given by it.
telephone fax e-mail
++91 80-2334 3188 ++91 80-2334 3178 [email protected]
Fosroc Chemicals (India) Pvt. Ltd.Head Office‘Vishnu Chittam’, No. 10, 2nd FloorSirur Park B Street, SeshadripuramBangalore 560020www.fosroc.com
® Denotes the trademark of Fosroc International Limited
Regional OfficesBangalore Mumbai Delhi Kolkata‘Vishnu Chittam’, No.10, 1stFloor 208/209, Persepolis 109-113, 1st Floor, Vikrant Towers P-569, Lake Terrace Extn.Sirur Park B Street, Seshadripuram Sector 17, Vashi 4, Rajendra Place First FloorBangalore 560 020 Navi Mumbai 400 703 New Delhi 110 008 Kolkata 700 029Ph:080-2334 3188 Ph:022-2789 6411/12 Ph:011- 45062000-5 Ph: 033 24650917 / 55343188Fax : 080-23368667 Fax: 022 - 2789 6413 Fax: 011- 45062001 Fax: 033-24650891email: [email protected] email:[email protected] email:[email protected] email:[email protected]
Ahmedabad : (079) 26762799 Ankleshwar :(02646) 220704/224687 Bellary: 09845891690 Bhubaneshwar : (0674) 2521176 Chennai : (044) 24899949/24853383 Chandigarh : (0172) 2639360 Cochin : (0484) 2347465 Coimbatore : (0422) 2472966 Goa : (0832) 09423058696 Guwahati : (0361) 2462866 Hyderabad : (040) 27662324/27662425 Indore : (0731) 4049339 Jaipur : (0141) 2336103 Lucknow :(0522) 2239044 Nagpur: (0712) 2753510/2563242 Visakhapatnam : (0891) 2564850 / 2707607
Nito
bond
® A
R S
td.
constructive solutionsNitobond® AR Std.
Latex Acrylic polymer based cement modifier cumbonding aid with waterproofing property
Uses
For improving and bonding floor toppings, mortars andrenders
As a bonding agent for Renderoc and other cementitiousmortars
Polymer modified mortars and screeds for reinstatementof worn out/damaged concrete
Polymer modified concrete for improving theimpermeability and there by enhancing the waterproofingproperty
Advantages
Good adhesion - Provides good bond to concrete, masonry,stone work, plaster and block work.
Increased strength - Improves tensile and flexuralproperties of mortar.
Versatile - Compatible with all common hydraulic cements
User friendly - application by brush/spray
Improves cohesion - No bleeding and segregation
Description
Nitobond AR Std. is a single component latex acyrlic polymeremulsion used as bonding aid cum cement modifier withwaterproofing property.
Technical support
Fosroc offers technical support service to specifiers, endusers and contractors, as well as on-site technical assistancein locations all over the country.
Properties
Appearance : Milky white liquid
pH : 9-10
Mechanical Properties* Control Nitobond AR Std.
Compressive strength@ 28days (ASTM C109)(N/mm2) 18-20 22
Flexural strength@28 days (ASTM C348) 3.0 5.0
Adhesion to concrete(ASTM C882) (Slant shear) 3.5 5.0
Mix proportions:
As a cement modifier :
1 litre Nitobond AR Std. : 5 kg cement : 15 kgs graded quartzsand.
As a bonding agent :
0.5 part cement : 1 part Nitobond AR Std. by weight.
As waterproofing agent:
2-5% of Nitobond AR Std. shall be mixed with concrete byweight of cement.
Application instructions
Surface Preparation
The object of the surface preparation is to achieve a cleansound surface with a good mechanical key. All substratesshould be cleaned and free of dust, plaster, oil, paint, grease,corrosion deposits, and any other deleterious substances.Laitence should be removed by mechanical means. Oil orgreasy deposits should be removed by suitable means. Allsurfaces so treated should be thoroughly washed with cleanwater. Smooth substrates must be mechanically roughenede.g. by scabbling, needle gun or grit/ sand blasting to providea mechanical key.
Concrete repairs : Any reinforcing steel in the repair areashould be exposed around its full circumference and cleanedto remove all loose scale and corrosion deposits and thenprimed with Nitocote AP35, acrylic primer. All surface dustand debris shall be removed.
Priming
Immediately before priming, the concrete substrate shouldbe thoroughly dampened with water and any excess beingbrushed off. Scrub Nitobond AR Std. bonding aid into thesubstrate. Puddling of the emulsion to be avoided. Therepair mortar/topping should be applied whilst the primer isstill tacky. However a satisfactory bond can be achieved upto15 mins. after application at 300C.
In order to obtain a smooth consistency mortar, the cementand sand must be dry mixed and then poured into the liquidwith the required amount of water in the prescribed mixproportions.
Nitobond® AR Std.
Additional Guidance
Edges shall be cut back to avoid feather edging and allsurfaces including edges shall be primed using Nitobond ARStd. bonding aid.
All applications shall be wet on wet. For best results NitobondAR Std. bonding aid should be allowed to become tacky. If thebonding agent is allowed to dry for more than 15 minutes at300 C initial 'grab' to the repair mortar will be reduced.Therefore, the use of temporary shuttering is recommended.Water content of the mortar should be kept to the minimumnecessary.
For consistent results, the use of clean, dry sand isrecommended. Where the use of wet sand is unavoidable,the quantity of water to be added must be reduced.
Mortars shall be cured using Nitobond AR Std. bonding aid toprevent rapid drying out. Uncured mortar shall be protectedfrom frost and rain.Mortar shall not be retampered after initial set.
Minimum application temperature for Nitobond AR Std.bonding aid is 100C, but the mortar should not be appliedif the temperature is expected to fall.
For permanently immersed conditions local Fosroc officeshall be consulted.
Limitations
As a bonding agent
Nitobond AR Std. bonding aid may exhibit less overlay time athigher temperature. In such cases, overlay mortar shall notbe applied when Nitobond AR Std. bonding aid is totally dry.
Nitobond AR Std. bonding aid when used as bonding agentcannot act as a barrier coat against ingress of chloride ionsfrom the substrate.
Equipment cleaning
Immediately after use, wash all tools with clean water.
Estimating
Packaging
Nitobond AR Std. bonding aid is supplied in 1, 5 and 20 litreplastic containers.
Estimation
As a cement modifier
Approximately 6 - 8m2/ litre depending on substrate. 21kgof mixed polymer mortar ( 1 part polymer, 5 parts cement &15 parts quartz sand) will yield approximately 10 -11 litres.
As a bonding agent
Approximately 3 - 4 m2/litre* depending on substrateconditions. (* 0.5 part cement : 1 part of Nitobond AR Std. byweight.
As waterproofing agent
2-5% of Nitobond AR Std. shall be mixed with concrete byweight of cement.
Nitobond® AR Std.
Storage
Shelf life
Nitobond AR Std. bonding aid has a shelf life of 12 months at300C. Nitobond AR Std. bonding aid should be protected fromfrost.
Precautions
Health & Safety instructions
Nitobond AR Std. bonding aid is non toxic. However it shouldnever be ingested and if it comes into contact with eyes, itshall be washed immediately with plenty of water and medicaltreatment shall be sought immediately.
Nitobond AR Std. bonding aid is slightly alkaline. Skin contactshould be avoided. Gloves and protective clothing should beworn.
Fire
Nitobond AR Std. bonding aid is non flammable.
Additional Information
Nitobond AR Std. is a part of wide range of adhesives, repairmortars, sealing compounds and flooring products speciallydesigned and manufactured by Fosroc for the constructionindustry.
Separate datasheets are available on all these products.
Nitobond® AR Std.
INDIA/922/B
Important note :Fosroc products are guaranteed against defective materials and manufacture and are sold subjectto its standard terms and conditions of sale, copies of which may be obtained on request. WhilstFosroc endeavours to ensure that any advice, recommendation specification or information it maygive is accurate and correct, it cannot, because it has no direct or continuous control over whereor how its products are applied, accept any liability either directly or indirectly arising from theuse of its products whether or not in accordance with any advice, specification, recommendationor information given by it.
telephone fax e-mail
++91 80-2334 3188 ++91 80-2334 3178 [email protected]
Fosroc Chemicals (India) Pvt. Ltd.Head Office‘Vishnu Chittam’, No. 10, 2nd FloorSirur Park B Street, SeshadripuramBangalore 560020www.fosroc.com
® Denotes the trademark of Fosroc International Limited
Regional OfficesBangalore Mumbai Delhi Kolkata‘Vishnu Chittam’, No.10, 1stFloor 208/209, Persepolis 109-113, 1st Floor, Vikrant Towers P-569, Lake Terrace Extn.Sirur Park B Street, Seshadripuram Sector 17, Vashi 4, Rajendra Place First FloorBangalore 560 020 Navi Mumbai 400 703 New Delhi 110 008 Kolkata 700 029Ph:080-2334 3188 Ph:022-2789 6411/12 Ph:011- 45062000-5 Ph: 033 24650917 / 55343188Fax : 080-23368667 Fax: 022 - 2789 6413 Fax: 011- 45062001 Fax: 033-24650891email: [email protected] email:[email protected] email:[email protected] email:[email protected]
Ahmedabad : (079) 26762799 Ankleshwar :(02646) 220704/224687 Bellary: 09845891690 Bhubaneshwar : (0674) 2521176 Chennai : (044) 24899949/24853383 Chandigarh : (0172) 2639360 Cochin : (0484) 2347465 Coimbatore : (0422) 2472966 Goa : (0832) 09423058696 Guwahati : (0361) 2462866 Hyderabad : (040) 27662324/27662425 Indore : (0731) 4049339 Jaipur : (0141) 2336103 Lucknow :(0522) 2239044 Nagpur: (0712) 2753510/2563242 Visakhapatnam : (0891) 2564850 / 2707607
Nito
bond
® E
P
constructive solutionsNitobond® EP
Epoxy resin concrete bonding agent
Uses
For bonding new cementitious materials to existingcementitious surfaces. For use on horizontal surfaces andon vertical surfaces where mortar or concrete can besupported by formwork. Ideal for extensions and repairs tostructural concrete in buildings, loading bays, bridges, roads,bonded or granolithic floor toppings etc.
Advantages
Nitobond EP can be applied by brush.
More overlay time:Enables to place the concrete upto 6hrs after applying Nitobond EP, without risk ofdelamination
High bond strength : Bond strength is more than thetensile strength of good quality concrete
Barrier coat : Acts as a 'barrier coat' to the migration ofchloride ions from host concrete.
Description
Nitobond EP is based on solvent free epoxy resins containingpigments and fine fillers. It is supplied as a two part materialin preweighed quantities for ready onsite mixing and use.Coloured components - white base and green hardener -provide visual evidence that adequate mixing is achieved.
Technical support
The company provides a technical advisory service supportedby a team of specialists in the field.
Design criteria
Nitobond EP is designed with an overlay time of 10 hrs at200C, 6 hours at 30 0C making it more suitable for use whereadditional steel reinforcement and formwork has to be fittedor where temperature is high. The minimum applicationtemperature for Nitobond EP is 10 0C. Consult the local Fosrocoffice for further information.
Properties
At 200C At 30 0C
Pot life 5 - 6 hrs 2 - 3 hrs
Full cure 7 days 5 days
Overlay time 10 hrs 6 hrs
Compressive strengthBS 6319 Pt 2 @ 7 days 50 N/mm2
Flexural strengthBS 6319 Pt 3 @ 7 days 35 N/mm2
Tensile strengthBS 6319 Pt 7 @ 7 days 20 N/mm2
Shear strengthBS 6319 Pt 4 @ 7 days 10 N/mm2
Adhesive strength to concrete : In general the bond strengthwill always exceed the tensile strength of M30 concrete.
Specification clauses
The bonding agent shall be Nitobond EP an epoxy based twocomponent resin system prepacked in distinct colours to givevisual evidence for proper mixing. The bonding agent shouldremain in tacky state after application for a minimum periodof 6 hours at 300C. There shall not be bond failure of thespecimen when tested by slant shear method according toBS 6319 pt 4, with M30 concrete.
Application instructions
Preparation
All surfaces to be treated must be firm, dust free and clean.All laintence should be removed by etching with Reebaklensand wire-brushing. In some cases, the existing concretemust be chipped to a sound substrate. Where surfaces arecontaminated with oil or grease, this should be removed byusing a strong industrial detergent or organic degreaser.Surface should be washed thoroughly with water and driedbefore the application of Nitobond EP.
Mixing
The entire contents of the hardener can should be pouredinto the resin container and the two materials thoroughly mixeduntil a uniform colour is obtained. To facilitate application attemperatures below 10 0C the separate components shouldbe warmed in hot water to a maximum of 25 0C before mixing.
Coating
Mixed Nitobond EP should be brush applied to the preparedsurface. The new concrete should be placed within 6 hoursat 300C to the Nitobond EP coated substrate, when it is in atacky state.
Nitobond® EP
INDIA/0901/E
Important note :Fosroc products are guaranteed against defective materials and manufacture and are sold subjectto its standard terms and conditions of sale, copies of which may be obtained on request. WhilstFosroc endeavours to ensure that any advice, recommendation specification or information it maygive is accurate and correct, it cannot, because it has no direct or continuous control over whereor how its products are applied, accept any liability either directly or indirectly arising from theuse of its products whether or not in accordance with any advice, specification, recommendationor information given by it.
telephone fax e-mail
++91 80-2334 3188 ++91 80-2334 3178 [email protected]
Fosroc Chemicals (India) Pvt. Ltd.Head Office‘Vishnu Chittam’, No. 10, 2nd FloorSirur Park B Street, SeshadripuramBangalore 560020www.fosroc.com
® Denotes the trademark of Fosroc International Limited
Regional OfficesBangalore Mumbai Delhi Kolkata‘Vishnu Chittam’, No.10, 1stFloor 208/209, Persepolis 109-113, 1st Floor, Vikrant Towers P-569, Lake Terrace Extn.Sirur Park B Street, Seshadripuram Sector 17, Vashi 4, Rajendra Place First FloorBangalore 560 020 Navi Mumbai 400 703 New Delhi 110 008 Kolkata 700 029Ph:080-2334 3188 Ph:022-2789 6411/12 Ph:011- 45062000-5 Ph: 033 24650917 / 55343188Fax : 080-23368667 Fax: 022 - 2789 6413 Fax: 011- 45062001 Fax: 033-24650891email: [email protected] email:[email protected] email:[email protected] email:[email protected]
Ahmedabad : (079) 26762799 Ankleshwar :(02646) 220704/224687 Bellary: 09845891690 Bhubaneshwar : (0674) 2521176 Chennai : (044) 24899949/24853383 Chandigarh : (0172) 2639360 Cochin : (0484) 2347465 Coimbatore : (0422) 2472966 Goa : (0832) 09423058696 Guwahati : (0361) 2462866 Hyderabad : (040) 27662324/27662425 Indore : (0731) 4049339 Jaipur : (0141) 2336103 Lucknow :(0522) 2239044 Nagpur: (0712) 2753510/2563242 Visakhapatnam : (0891) 2564850 / 2707607
Limitations
Nitobond EP should not be applied when the temperature isbelow 100C. If any doubts arise concerning temperature orsubstrate conditions, consult the local Fosroc office.
Estimating
Packaging
Available in 1/2, 1 and 4 litre industrial packs.
Coverage
Approximately 2.6 m2/litre. Actual coverage will depend uponthe texture and porosity of the substrate being covered.
Storage
Shelf life
12 months if stored under normal warehouse conditionsbelow 350C, in unopened containers.
Precautions
Health and Safety
Contact with skin and eyes should be avoided. Gloves shouldbe used when handling these products. If contact wiith theresin occurs, wash immediately with a strong detergent or aresin removing cream. Eye contamination must beimmediately washed with plenty of water and medicaltreatment sought.
Fire
Nitobond EP is inflammable. No naked flame should beallowed near the site. Do not smoke during use.
Additional information
Fosroc manufactures a wide range of products specificallydesigned for the repair and refurbishment of damagedreinforced concrete. This includes repair mortars, fluid micro-concretes, chemical resistant epoxy mortars and acomprehensive package of protective coatings. In addition,a wide range of complementary products are available. Thisincludes joint sealants, waterproofing membranes, groutsand anchors and specialised flooring materials.
Separate datahsheets are available on these products.
Nito
bond
® P
C
constructive solutionsNitobond® PC
Thixotropic epoxy adhesive
Uses
Bonding segmented concrete bridges / structures to speedup construction and provide a structural and water resistantjoint. Can be used for pointing Stone masonry joints to retainstructural integrity .
Advantages
Excellent squeezability
High bond strength
Fast cure
Tolerant to damp surfaces
Wide range of temperature applications
Standards compliance
Nitobond PC fully conforms to meets the FIP specifications.
Description
Nitobond PC thixotropic epoxy adesive is a 2 pack solventfree epoxy resin system consisting of a white base and blackhardener in preweighed quantities for easy onsite mixing.The product is available in three grades :
Nitobond PC20 - Fast set for application between 50C to200 C
Nitobond PC 30 - Medium Fast set for application between150C to 300C
Nitobond PC40 - Slow set for application between 250Cto 400C
Technical Support
Fosroc provides a technical advisory service supported by ateam of specialists in the field.
Properties
Colour Base - WhiteHardener - BlackMixed - Grey
Specific gravity at 300C 1.60 - 1.65
Cure characteristics
Recommended Pot life ** Open Application (Mins.) Time Temperature (Mins.)
Nitobond PC20 50C-200C 30 at 200C 60 at 200C
Nitobond PC30 150C-300C 30 at 300C 60 at 300C
Nitobond PC40 250C-400C 30 at 400C 60 at 400C
** for 100 g of mixed material
Mechanical properties
Squeezability Meets the requirement(FIP 5.4)
Compressive @ 24 hours > 40N/mm2
Strength (FIP 5.6) @ 7days > 75N/mm2
Tensile bending strength Concrete failure(FIP 5.14)
Shear Strength 13N/mm2
(FIP 5.15)
Application instructions
Surface Preparation
Concrete should be mechanically sound and free fromcontamination, such as free water, mould, oil or grease,laitence and dust. Grit blasting is recommended. Sectionsto be bonded should be checked for good alignment. A 'dryrun' before the first application of the adhesive isrecommended to ensure correct timing.
Mixing
The base and hardener into a suitable container shall beemptied and mixed with a paddle and slow speed heavy dutydrill, ensuring the sides are scraped down. A uniform greycolour should be obtained after mixing thoroughly.
Application
The mixed adhesive is applied to both surfaces to be bondedwith a serrated trowel or other suitable spreader.
The joint should be closed immediately, if this is not achievedthe surface of the adhesive should be slightly scratchedimmediately prior to closing the joint to expose fresh adhesive.The joint must be closed within the open time of the adhesive.On site monitoring of the operation using lapped asbestoscement panels is recommended.
Nitobond® PC
INDIA/0908/E
Important note :Fosroc products are guaranteed against defective materials and manufacture and are sold subjectto its standard terms and conditions of sale, copies of which may be obtained on request. WhilstFosroc endeavours to ensure that any advice, recommendation specification or information it maygive is accurate and correct, it cannot, because it has no direct or continuous control over whereor how its products are applied, accept any liability either directly or indirectly arising from theuse of its products whether or not in accordance with any advice, specification, recommendationor information given by it.
telephone fax e-mail
++91 80-2334 3188 ++91 80-2334 3178 [email protected]
Fosroc Chemicals (India) Pvt. Ltd.Head Office‘Vishnu Chittam’, No. 10, 2nd FloorSirur Park B Street, SeshadripuramBangalore 560020www.fosroc.com
® Denotes the trademark of Fosroc International Limited
Regional OfficesBangalore Mumbai Delhi Kolkata‘Vishnu Chittam’, No.10, 1stFloor 208/209, Persepolis 109-113, 1st Floor, Vikrant Towers P-569, Lake Terrace Extn.Sirur Park B Street, Seshadripuram Sector 17, Vashi 4, Rajendra Place First FloorBangalore 560 020 Navi Mumbai 400 703 New Delhi 110 008 Kolkata 700 029Ph:080-2334 3188 Ph:022-2789 6411/12 Ph:011- 45062000-5 Ph: 033 24650917 / 55343188Fax : 080-23368667 Fax: 022 - 2789 6413 Fax: 011- 45062001 Fax: 033-24650891email: [email protected] email:[email protected] email:[email protected] email:[email protected]
Ahmedabad : (079) 26762799 Ankleshwar :(02646) 220704/224687 Bellary: 09845891690 Bhubaneshwar : (0674) 2521176 Chennai : (044) 24899949/24853383 Chandigarh : (0172) 2639360 Cochin : (0484) 2347465 Coimbatore : (0422) 2472966 Goa : (0832) 09423058696 Guwahati : (0361) 2462866 Hyderabad : (040) 27662324/27662425 Indore : (0731) 4049339 Jaipur : (0141) 2336103 Lucknow :(0522) 2239044 Nagpur: (0712) 2753510/2563242 Visakhapatnam : (0891) 2564850 / 2707607
Cleaning of Application Equipment
Tools and equipment should be cleaned immediately afteruse with Nitoflor Sol.
Estimating
Packaging
30 Ltr. bulk packs and 3.7 L standard packs.
Coverage
Approximately 2 L/m2 at 2 mm thickness
Storage
Shelf Life
12 months if stored below 350C in unopened containers.
Precautions
Health and Safety
Some people are sensitive to epoxy resin system and maydevelop dermatitis. Direct contact with eyes will cause irritationand may cause serious damage if left untreated. Any eyecontamination should be washed thoroughly with water andimmediate medical attention should be sought. Gloves, barriercreams and eye protection should always be used when
handling Nitobond PC and Nitoflor Sol.
If contact with skin occurs, a resin removing cream should beused, followed by washing with soap and water. Solvent shallnot be used.
Fire
Nitobond PC base and hardener are nonflammable. NitoflorSol is flammable. Do not use near naked flames. Nosmoking.
Flash Points :
Nitobond PC Base 1000C(Abel open cup )
Nitobond PC Hardener 1000C(Abel open cup )
Nitoflor Sol Solvent 330C(Abel closed cup method IP 33 )
Additional information
Nitobond PC is a part of wide range of adhesives, repairmaterials, sealing and waterproofing compounds, grouts andflooring products manufactured by Fosroc for the constructionindustry.
Separate datasheet is available on these products.
Nito
bond
® S
BR
constructive solutionsNitobond® SBR
Mortar and Screed modifier cum bonding aid
Uses
For modifying and improving bonding of floor toppings,renderings and mortars; repair of worn, damaged and spalledconcrete, repair of large cracks; polymer modified floorscreeds; waterproof plasters for masonary and slurries.
Advantages
Simple to use - Single component, gauged as required.
High adhesion - Provides excellent bond to concrete,adhesion plaster, masonry, stone work, etc.
Improves durability -Gives weather resistant mortar withimproved impermeability to chlorides and other harmfulagents.
Reduces permeability- Provides waterproof screeds,plasters and permeability slurries.
Increases strength - Improved tensile and flexuralproperties allow thin applications.
Versatile - Compatible with all common hydraulic cements.
Cost effective - Nitobond SBR is economical to use
Description
Nitobond SBR is modified styrene butadiene rubber emulsionspecially designed for use as a bonding aid and gaugingliquid for cementitious systems. It is resistant to hydrolysisand can therefore be used for external applications too.
Technical Support
Fosroc provides a technical advisory service supported by ateam of specialists in the field.
Properties
Typical mechanical properties of 1 : 3 cement sand mortar atW/C - 0.45 for control and W/C - 0.35 for mortar containingNitobond SBR ( 5 lites / 50 kg cement ). Tested in accordancewith BS 6319 & wet cured.
Mechanical properties Control Nitobond SBR
Compressive strength (N/mm2)
3 days 11.5 12.57 days 13.0 14.528 days 22.0 24.0
Tensile strength(N/mm2) @ 28 days 2.5 3.5
Flexural strength(N/mm2) @ 28 days 5.0 6.5
Note : Increased dosages of Nitobond SBR and further waterreduction leads to improved mechanical properties.
Chemical resistance :
Cementitious based materials have limited chemicalresitance. The addition of Nitobond SBR to cement mortarsreduces permeability and therefore helps reduce the rate ofattack by aggressive chemicals.
Application instructions
Surface Preparation:
The object of the surface preparation is to achieve a cleansound surface with a good mechanical key. All substratesshould be cleaned and free of dust, plaster, oil, paint, grease,corrosion deposits, and any other deleterious substances.Laitence should be removed by mechanical means. Smoothsubstrates must be mechanically roughened e.g. byscabbling, needle gun or grit blasting to provide an adequatekey.
Corroded reinforcing steel should be exposed around its fullcircumference and cleaned to remove all loose scale andcorrosion deposits. It is always preferably to clean the steelto a bright condition. Use of emery cloth, grit or sand blastingis recommended.
Priming
Reinforcing steel must be primed with Nitozinc Primerimmediately after cleaning. The concrete substrate shouldbe thoroughly dampened with water and any excess waterremoved before being primed by thoroughly scrubbing in aslurry coat of 1 volume Nitbond SBR to 1 volume water to 3volumes fresh cement.
In order to obtain a smooth consistency the cement shouldbe blended slowly into the liquids. Stir frequently during useto offset settlement.
Nitobond® SBR
Avoid 'puddling' of the slurry coat. The topping must be appliedon to the wet slurry. If the slurry dries out it must be removedand the clean substrate reprimed.
Typical Mix designs :
1. Patching and repair mortars and plaster for masonary
Cement 50 kgZone II sand 150 kgNitobond SBR 5 - 9 litresRecommended water addition 11 - 15 litresRecommended thickness 8 to 30mm
2. Heavy duty floor screeds
Cement 50 kg3-6mm Granite chips 75 kgZone II sand 75 kgNitobond SBR 5-9 litresRecommended water addition 8-12 litresRecommended thickness 10-25mm
The screed should be of a semi-dry cohesive consistency.
Cleaning
Tools and equipment should be washed with waterimmediately after use.
Additional Guidance
Prepare surfaces thoroughly. Toe-in at edges whereverpossible to avoid feather edging.
All surfaces including edges must be primed.
All applications should be wet on wet, the primer must not beallowed to dry.
The level of added water in the mix designs may needadjustment to achieve the required consistency. In generalwater content should be kept to the minimum necessary.
For consistent performance the use of clean, dry sand isrecommended. Where wet sand is used, reduce the additionof water as appropriate.
In order to prevent rapid drying, mortars should be properlycured with Concure WB, curing compound.
Protect uncured mortar from frost.
Do not retemper mortar or primer after initial set.
Minimum application temperature is 100C. For permanentlyimmersed conditions consult Local Fosroc office.
Estimating
Packaging
Nitobond SBR is supplied in 1, 5 and 20 litre containers.
Coverage
Slurry primer - approximately 4- 5 m2/ litre depending onsubstrate porosity.
Storage
Shelf life
Nitobond SBR has a shelf life of 12 months if kept in a drystore in unopened condition.
Precautions
Health & Safety instructions
Nitobond SBR should not come in contact with skin and eyesor be swallowed. Protective gloves and goggles should beworn during handling the product.
If contact with skin occurs, wash well with soap and water.Eye contamination should be washed thoroughly with cleanwater and medical advice sought. If swallowed seek medicalattention immediately - Do not induce vomiting.
Fire
Nitobond SBR is non flammable.
Nitobond® SBR
Additional information
Nitobond SBR is part of a wide range of adhesives, repairmortars, sealing compounds and flooring products speciallydesigned and manufactured by Fosroc for the constructionindustry. Separate datasheets are available on all theseproducts.
Nitobond® SBR
INDIA/0905/C
Important note :Fosroc products are guaranteed against defective materials and manufacture and are sold subjectto its standard terms and conditions of sale, copies of which may be obtained on request. WhilstFosroc endeavours to ensure that any advice, recommendation specification or information it maygive is accurate and correct, it cannot, because it has no direct or continuous control over whereor how its products are applied, accept any liability either directly or indirectly arising from theuse of its products whether or not in accordance with any advice, specification, recommendationor information given by it.
telephone fax e-mail
++91 80-2334 3188 ++91 80-2334 3178 [email protected]
Fosroc Chemicals (India) Pvt. Ltd.Head Office‘Vishnu Chittam’, No. 10, 2nd FloorSirur Park B Street, SeshadripuramBangalore 560020www.fosroc.com
® Denotes the trademark of Fosroc International Limited
Regional OfficesBangalore Mumbai Delhi Kolkata‘Vishnu Chittam’, No.10, 1stFloor 208/209, Persepolis 109-113, 1st Floor, Vikrant Towers P-569, Lake Terrace Extn.Sirur Park B Street, Seshadripuram Sector 17, Vashi 4, Rajendra Place First FloorBangalore 560 020 Navi Mumbai 400 703 New Delhi 110 008 Kolkata 700 029Ph:080-2334 3188 Ph:022-2789 6411/12 Ph:011- 45062000-5 Ph: 033 24650917 / 55343188Fax : 080-23368667 Fax: 022 - 2789 6413 Fax: 011- 45062001 Fax: 033-24650891email: [email protected] email:[email protected] email:[email protected] email:[email protected]
Ahmedabad : (079) 26762799 Ankleshwar :(02646) 220704/224687 Bellary: 09845891690 Bhubaneshwar : (0674) 2521176 Chennai : (044) 24899949/24853383 Chandigarh : (0172) 2639360 Cochin : (0484) 2347465 Coimbatore : (0422) 2472966 Goa : (0832) 09423058696 Guwahati : (0361) 2462866 Hyderabad : (040) 27662324/27662425 Indore : (0731) 4049339 Jaipur : (0141) 2336103 Lucknow :(0522) 2239044 Nagpur: (0712) 2753510/2563242 Visakhapatnam : (0891) 2564850 / 2707607
Nito
bond
® S
BR45
constructive solutionsNitobond® SBR45
Mortar and Screed modifier cum bonding aid
Uses
For modifying and improving bonding of floor toppings,renderings and mortars; repair of worn, damaged and spalledconcrete, repair of large cracks; polymer modified floorscreeds; waterproof plasters for masonary and slurries.
Advantages
Simple to use : Single component, gauged as required.
High adhesion : Provides excellent bond to concrete, plaster,masonry, stone work, etc.
Improves durability : Gives weather resistant mortar withimproved impermeability to chlorides and other harmfulagents.
Reduces Permeability: Provides waterproof screeds,plasters and slurries.
Increases strength: Improved tensile and flexural propertiesallow thin applications.
Versatile : Compatible with all common hydraulic cements.
Cost effective : Nitobond SBR45 is economical to use.
Description
Nitobond SBR45 is modified styrene butadiene emulsionspecially designed for use as a bonding aid and gaugingliquid for cementitious systems. It is resistant to hydrolysisand can therefore be used for external applications too.
Technical Support
Fosroc provides a technical advisory service supported by ateam of specialists in the field.
Properties
Typical mechanical properties of 1 : 3 cement sand mortar atW/C - 0.45 for control and W/C - 0.35 for mortar containingNitobond SBR45 (5 litres / 50 kg cement ). Tested in accor-dance with BS 6319 & wet cured.
Mechanical properties Control Nitobond SBR45 mortar
Compressive strength (N/mm2)
3 days 11.5 12.57 days 13.0 14.528 days 22.0 24.0
Tensile strength(N/mm2) @ 28 days 2.5 3.50
Flexural strength(N/mm2) @ 28 days 5.0 6.50
Note : Increased dosages of Nitobond SBR45 and furtherwater reduction leads to improved mechanical properties.
Chemical resistance
Cementitious based materials have limited chemicalresistance. The addition of Nitobond SBR45 to cementmortars reduces permeability and therefore helps reducethe rate of attack by aggressive chemicals.
Application instructions
Surface Preparation
The object of the surface preparation is to achieve a cleansound surface with a good mechanical key. All substratesshould be cleaned and free of dust, plaster, oil, paint, grease,corrosion deposits, and any other deleterious substances.Laitence should be removed by mechanical means. Smoothsubstrates must be mechanically roughened e.g. byscabbling, needle gun or grit blasting to provide an adequatekey.
Corroded reinforcing steel should be exposed around its fullcircumference and cleaned to remove all loose scale andcorrosion deposits. It is always preferably to clean the steelto a bright condition. Use of emery cloth, grit or sand blastingis recommended.
Priming
Reinforcing steel must be primed with Nitozinc Primer im-mediately after cleaning. The concrete substrate should bethoroughly dampened with water and any excess removedbefore being primed by thoroughly scrubbing in a slurry coatof 1 volume Nitbond SBR45 to 1 volume water to 3 volumesfresh cement.
Nitobond® SBR45
In order to obtain a smooth consistency the cement shouldbe blended slowly into the liquids. Stir frequently during useto offset settlement.
Avoid 'puddling' of the slurry coat. The topping must be ap-plied on to the wet slurry. If the slurry dries out it must beremoved and the clean substrate reprimed.
Typical Mix designs :
1. Patching and repair mortars and plaster for masonary Cement 50 kg Zone II sand 150 kg Nitobond SBR45 5 litres Recommended water addition 11 - 15 ltrs Recommended thickness 8 to 30mm.
2. Heavy duty floor screeds Cement 50 kg 3-6mm Granite chips 75 kg Zone II sand 75 kg Nitobond SBR45 5 litres Recommended water addition 8-12 ltrs Recommended thickness 10-25mm
The screed should be of a semi-dry cohesive consistency.
Cleaning
Tools and equipment should be washed with waterimmediately after use.
Additional Guidance
Prepare surfaces thoroughly. Toe-in at edges whereverpossible to avoid feather edging.
All surfaces including edges must be primed.
All applications should be wet on wet, the primer must not beallowed to dry.
The level of added water in the mix designs may need adjust-ing to achieve the required consistency. In general watercontent should be kept to the minimum necessary.
For consistent performance the use of clean, dry sand isrecommended. Where wet sand is used, reduce the addedwater level as appropriate.
In order to prevent rapid drying, mortars should be properlycured with Concure WB, curing compound.
Protect uncured mortar from frost.
Do not retemper mortar or primer after initial set.
Minimum application temperature is 100C. For permanentlyimmersed conditions consult Local Fosroc office.
Nitobond® SBR45
Estimating
Packaging
Nitobond SBR45 is supplied in 1, 5 and 20 litre containers.
Coverage
Slurry primer - approximately 4- 5 m2/ litre depending onsubstrate porosity.
Storage
Shelf life
Nitobond SBR45 has a shelf life of 12 months if kept in a drystore in unopened condition.
Precautions
Health & Safety
Nitobond SBR45 should not come in contact with skin andeyes or be swallowed. Protective gloves and goggles shouldbe worn.
Nitobond SBR45 should not come in contact with skin andeyes or be swallowed.
If contact with skin occurs, wash well with soap and water.Eye contamination should be washed thoroughly with cleanwater and medical advice sought. If swallowed seek medi-cal attention immediately - Do not induce vomiting.
Fire
Nitobond SBR45 is non flammable.
Additional information
Nitobond SBR45 is part of a wide range of adhesives, repairmortars, sealing compounds and flooring products speciallydesigned and manufactured by Fosroc for the constructionindustry. Separate datasheets are available on all theseproducts.
Nitobond® SBR45
INDIA/0916/B
Important note :Fosroc products are guaranteed against defective materials and manufacture and are sold subjectto its standard terms and conditions of sale, copies of which may be obtained on request. WhilstFosroc endeavours to ensure that any advice, recommendation specification or information it maygive is accurate and correct, it cannot, because it has no direct or continuous control over whereor how its products are applied, accept any liability either directly or indirectly arising from theuse of its products whether or not in accordance with any advice, specification, recommendationor information given by it.
telephone fax e-mail
++91 80-2334 3188 ++91 80-2334 3178 [email protected]
Fosroc Chemicals (India) Pvt. Ltd.Head Office‘Vishnu Chittam’, No. 10, 2nd FloorSirur Park B Street, SeshadripuramBangalore 560020www.fosroc.com
® Denotes the trademark of Fosroc International Limited
Regional OfficesBangalore Mumbai Delhi Kolkata‘Vishnu Chittam’, No.10, 1stFloor 208/209, Persepolis 109-113, 1st Floor, Vikrant Towers P-569, Lake Terrace Extn.Sirur Park B Street, Seshadripuram Sector 17, Vashi 4, Rajendra Place First FloorBangalore 560 020 Navi Mumbai 400 703 New Delhi 110 008 Kolkata 700 029Ph:080-2334 3188 Ph:022-2789 6411/12 Ph:011- 45062000-5 Ph: 033 24650917 / 55343188Fax : 080-23368667 Fax: 022 - 2789 6413 Fax: 011- 45062001 Fax: 033-24650891email: [email protected] email:[email protected] email:[email protected] email:[email protected]
Ahmedabad : (079) 26762799 Ankleshwar :(02646) 220704/224687 Bellary: 09845891690 Bhubaneshwar : (0674) 2521176 Chennai : (044) 24899949/24853383 Chandigarh : (0172) 2639360 Cochin : (0484) 2347465 Coimbatore : (0422) 2472966 Goa : (0832) 09423058696 Guwahati : (0361) 2462866 Hyderabad : (040) 27662324/27662425 Indore : (0731) 4049339 Jaipur : (0141) 2336103 Lucknow :(0522) 2239044 Nagpur: (0712) 2753510/2563242 Visakhapatnam : (0891) 2564850 / 2707607
Nito
bond
® S
BR
(:ate
x)
constructive solutionsNitobond® SBR(Latex)
Mortar and Screed modifier cum bonding aid
Uses
For modifying and improving bonding of floor toppings,renderings and mortars; repair of worn, damaged and spalledconcrete, repair of large cracks; polymer modified floorscreeds; waterproof plasters for masonary and slurries.
Advantages
Simple to use - Single component, gauged as required.
High - Provides excellent bond to concrete, adhesionplaster, masonry, stone work, etc.
Improves -Gives weather resistant mortar with improveddurability impermeability to chlorides and other harmfulagents.
Reduces - Provides waterproof screeds, plasters andPermeability slurries.
Increases - Improved tensile and flexural propertiesstrength allow thin applications.
Versatile - Compatible with all common hydraulic cements.
Cost effective - Nitobond SBR (Latex) is economical touse
Description
Nitobond SBR(Latex) is modified styrene butadiene emulsionspecially designed for use as a bonding aid and gauging liquidfor cementitious systems. It is resistant to hydrolysis and cantherefore be used for external applications too.
Technical Support
Fosroc provides a technical advisory service supported by ateam of specialists in the field.
Properties
Typical mechanical properties of 1 : 3 cement sand mortar atW/C - 0.45 for control and W/C - 0.35 for mortar containingNitobond SBR (Latex) ( 5 lites / 50 kg cement ). Tested inaccordance with BS 6319 & wet cured.
Mechanical properties Control Nitobond SBR (Latex)
Compressive strength (N/mm2)
3 days 11.5 12.57 days 13.0 14.528 days 22.0 24.0
Tensile strength(N/mm2) @ 28 days 2.5 3.5
Flexural strength(N/mm2) @ 28 days 5.0 6.5
Note : Increased dosages of Nitobond SBR (Latex) andfurther water reduction leads to improved mechanicalproperties.
Chemical resistance :
Cementitious based materials have limited chemicalresitance. The addition of Nitobond SBR (Latex) to cementmortars reduces permeability and therefore helps reduce therate of attack by aggressive chemicals.
Application instructions
Surface Preparation:
The object of the surface preparation is to achieve a cleansound surface with a good mechanical key. All substratesshould be cleaned and free of dust, plaster, oil, paint, grease,corrosion deposits, and any other deleterious substances.Laitence should be removed by mechanical means. Smoothsubstrates must be mechanically roughened e.g. byscabbling, needle gun or grit blasting to provide an adequatekey.
Corroded reinforcing steel should be exposed around its fullcircumference and cleaned to remove all loose scale andcorrosion deposits. It is always preferably to clean the steelto a bright condition. Use of emery cloth, grit or sand blastingis recommended.
Priming
Reinforcing steel must be primed with Nitozinc Primerimmediately after cleaning. The concrete substrate shouldbe thoroughly dampened with water and any excess removedbefore being primed by thoroughly scrubbing in a slurry coatof 1 volume Nitbond SBR (Latex) to 1 volume water to 3volumes fresh cement.
In order to obtain a smooth consistency the cement shouldbe blended slowly into the liquids. Stir frequently during useto offset settlement.
Nitobond® SBR(Latex)
Avoid 'puddling' of the slurry coat. The topping must be appliedon to the wet slurry. If the slurry dries out it must be removedand the clean substrate reprimed.
Typical Mix designs :
1. Patching and repair mortars and plaster for masonary
Cement 50 kgZone II sand 150 kgNitobond SBR (Latex) 5 - 9 litresRecommended water addition 11 - 15 litresRecommended thickness 8 to 30mm
2. Heavy duty floor screeds
Cement 50 kg3-6mm Granite chips 75 kgZone II sand 75 kgNitobond SBR (Latex) 5-9 litresRecommended water addition 8-12 litresRecommended thickness 10-25mm
The screed should be of a semi-dry cohesive consistency.
3. Polymer modified cement grout for injection - NitobondSBR (Latex) can be used to effectively modify properties ofcement grout for crack injection. The dosage of NitobondSBR(Latex) shall be in the range of 3 L/bag of cement. Theinjection is carried out as per standard practice.
Cleaning
Tools and equipment should be washed with waterimmediately after use.
Additional Guidance
Prepare surfaces thoroughly. Toe-in at edges whereverpossible to avoid feather edging.
All surfaces including edges must be primed.
All applications should be wet on wet, the primer must not beallowed to dry.
The level of added water in the mix designs may need adjustingto achieve the required consistency. In general water contentshould be kept to the minimum necessary.
For consistent performance the use of clean, dry sand isrecommended. Where wet sand is used, reduce the addedwater level as appropriate.
In order to prevent rapid drying, mortars should be properlycured with Concure WB, curing compound.
Protect uncured mortar from frost.
Do not retemper mortar or primer after initial set.
Minimum application temperature is 100C. For permanentlyimmersed conditions consult Local Fosroc office.
Estimating
Packaging
Nitobond SBR (Latex) is supplied in 1, 5 and 20 litrecontainers.
Coverage
Slurry primer - approximately 4- 5 m2/ litre depending onsubstrate porosity.
Storage
Shelf life
Nitobond SBR (Latex) has a shelf life of 12 months if kept in adry store in unopened condition.
Precautions
Health & Safety instructions
Nitobond SBR (Latex) should not come in contact with skinand eyes or be swallowed. Protective gloves and gogglesshould be worn.
Nitobond SBR (Latex) should not come in contact with skinand eyes or be swallowed.
If contact with skin occurs, wash well with soap and water.Eye contamination should be washed thoroughly with cleanwater and medical advice sought. If swallowed seek medicalattention immediately - Do not induce vomiting.
Nitobond® SBR(Latex)
Fire
Nitobond SBR (Latex) is non flammable.
Additional information
Nitobond SBR (Latex) is part of a wide range of adhesives,repair mortars, sealing compounds and flooring productsspecially designed and manufactured by Fosroc for theconstruction industry. Separate datasheets are available onall these products.
Nitobond® SBR(Latex)
INDIA/0923/C
Important note :Fosroc products are guaranteed against defective materials and manufacture and are sold subjectto its standard terms and conditions of sale, copies of which may be obtained on request. WhilstFosroc endeavours to ensure that any advice, recommendation specification or information it maygive is accurate and correct, it cannot, because it has no direct or continuous control over whereor how its products are applied, accept any liability either directly or indirectly arising from theuse of its products whether or not in accordance with any advice, specification, recommendationor information given by it.
telephone fax e-mail
++91 80-2334 3188 ++91 80-2334 3178 [email protected]
Fosroc Chemicals (India) Pvt. Ltd.Head Office‘Vishnu Chittam’, No. 10, 2nd FloorSirur Park B Street, SeshadripuramBangalore 560020www.fosroc.com
® Denotes the trademark of Fosroc International Limited
Regional OfficesBangalore Mumbai Delhi Kolkata‘Vishnu Chittam’, No.10, 1stFloor 208/209, Persepolis 109-113, 1st Floor, Vikrant Towers P-569, Lake Terrace Extn.Sirur Park B Street, Seshadripuram Sector 17, Vashi 4, Rajendra Place First FloorBangalore 560 020 Navi Mumbai 400 703 New Delhi 110 008 Kolkata 700 029Ph:080-2334 3188 Ph:022-2789 6411/12 Ph:011- 45062000-5 Ph: 033 24650917 / 55343188Fax : 080-23368667 Fax: 022 - 2789 6413 Fax: 011- 45062001 Fax: 033-24650891email: [email protected] email:[email protected] email:[email protected] email:[email protected]
Ahmedabad : (079) 26762799 Ankleshwar :(02646) 220704/224687 Bellary: 09845891690 Bhubaneshwar : (0674) 2521176 Chennai : (044) 24899949/24853383 Chandigarh : (0172) 2639360 Cochin : (0484) 2347465 Coimbatore : (0422) 2472966 Goa : (0832) 09423058696 Guwahati : (0361) 2462866 Hyderabad : (040) 27662324/27662425 Indore : (0731) 4049339 Jaipur : (0141) 2336103 Lucknow :(0522) 2239044 Nagpur: (0712) 2753510/2563242 Visakhapatnam : (0891) 2564850 / 2707607
Nito
cote
®ET
402
constructive solutionsNitocote® ET402
Coal tar extended epoxy resin coating
Uses
Provides chemical and abrasion resistance to preventcorrosion of concrete surfaces for applications such as :
Seawater tanks, channels and intakes.
Manhole linings.
Sewage works and effluent plants.
Chemical processing.
Foundation waterproofing.
Jetties, piers and docks.
Advantages
Low cost service life - excellent chemical and abrasionresistance, does not support bacterial growth.
Cost saving - primerless system.
Added value system - acts as an impermeablewaterproof coating.
Versatile usage - can be applied to green concrete bybrush, roller or spray.
Description
Nitocote ET402 is based on solvent-free epoxy resins, modifiedwith coal tar. It is supplied as a two pack material in pre-weighed quantities ready for on-site mixing and use.
Nitocote ET402 is applied as a two coat application. It isgenerally applied at a wet film thickness of 200 micron percoat, but can be applied at greater thicknesses to suit exposureconditions. Nitocote ET402 is available in marine grade forapplications necessitating biocidal and micro-biostatic effect.
Specification
The corrosion resistant coating shall be Nitocote ET402, acoal tar extended, 100% solids, epoxy resin coating. Thecoating shall possess a high-build capability, to facilitatevarying application thicknesses. It shall further possessexcellent bond and chemical resistance properties and shallcomply to BS 7542 & ASTM C309 curing efficiency standards.
Properties
Colour : Black/Brown
Solids by weight @ 25°C : 100%
Specific gravity : 1.54 at 27°C
Pot life : at 25°C 75 minutes at 40°C 40 minutes
Tack free time : 2 to 3 hours at 35°C
Overcoating time : 6 hours at 35°C3 hours at 45°C
Full cure : 4 days at 35°C
Curing Efficiency : 93%(BS 7542)
Water Absorption : <0.01%(ASTM D570)
Impact Resistance : Passed(BS 3900 Pt E3)
Bond Strength : Min 1N/mm²(BS 1881 Pt 207)
Water Permeability : Nil @ 2 bar pressure(Long Term) over 3 months
Salt Spray Test : Nil @ 200 microns(BS 1881 Pt. 124 :1988) tested over 1000 hours
Chemical resistance : Tests were carried out inaccordance with ASTM D543. Test was conducted at roomtemperature of 23°C and specimens were soaked in thesolution for a period of 7 days.
Acids (m/v)
Hydrochloric acid 10% : ExcellentSulphuric acid 10% : Very goodNitric acid 10% : Very goodPhosphoric acid 10% : Very good
Alkalis (m/v)
Ammonia 15% : ExcellentSodium Hydroxide 25% : Good
Solvents & organics
Oils, vegetable and minerals: ExcellentFerric Chloride 15% : Very good
Nitocote® ET402
Aqueous solutions
Water : ExcellentSea water : ExcellentRaw sewage : Very good
Consult the local Fosroc office for specific recommendationsto meet each operating condition.
Instructions for use
Preparation
All surfaces to be treated with Nitocote ET402 must be cleanand free from dust or loose material.
Concrete surfaces
All laitance must be removed by grit blasting, or other suitableremoval methods. The general standard of surfacepreparation should be in accordance with ACI 503R-89,Chapter 5, Paragraph 5.4. Following the preparation of aconcrete surface, care should be taken to ensure that anysurface irregularities are filled with Nitomortar FC*† orNitomortar FC(B)*†.
Metal surfaces
Any metal surfaces should be grit blasted to a bright finish,meeting the requirements of Swedish Standard SA 2½ orequal.
Priming
Concrete surfaces
Priming is not required on properly prepared concretesurfaces - see Preparation section.
Metal surfaces
All metal surfaces should be coated immediately afterpreparation. If this is not possible and to eliminate formationof rust, prime the metal surfaces using Nitoprime 25*.
Mixing
The contents of the resin can should be thoroughly stirred todisperse any possible settlement. The entire contents ofboth the hardener and resin cans should be poured into asuitable sized mixing vessel. It is recommended that the twocomponents are mixed together mechanically using a slowspeed electric drill fitted with a Mixing Paddle.. Mixing shouldbe carried out continuously for 3 to 5 minutes, until a uniformconsistency is achieved.
Although Nitocote ET402 is a non-solvented product, it is stillrecommended that mixing should take place in an open, wellventilated area.
Application
A minimum 2 coat application is generally recommended toensure a full, unbroken coating is achieved.
Brush application
Once mixed, the material should be immediately applied,ensuring that a continuous coating is obtained. The first coatis applied to achieve a uniform coating with a wet film thicknessnot less than 200 microns, and should be allowed to dry forat least 6 hours at 35°C before the application of the secondcoat.
The second coat should be applied between 6 hours and 4days (at 35°C) after the application of the first coat, at 45°Cthis will be reduced to 3 hours. The second coat should beapplied as above again achieving a wet film thickness notless than 200 microns.
Spray application
Where large areas are to be coated, it is advisable to considerspray application. Consult the local Fosroc office for furtherdetails and recommendations.
Cleaning
Tools and equipment should be cleaned with Nitoflor Solimmediately after use.
Hot weather working practices
Whilst the performance properties of Nitocote ET402 atelevated temperatures are assured, application under suchconditions can sometimes be difficult. It is therefore suggestedthat, for temperatures above 35°C, the following guidelinesare adopted as a prudent working regime:
i Store unmixed materials in a cool (preferablytemperaturecontrolled) environment, avoiding exposureto direct sunlight.
ii Keep mixing and placing equipment cool, arranging shadeprotection if necessary. It is especially important to keepcool those surfaces of the equipment which will come intodirect contact with the material itself.
iii Try to eliminate application in the middle of the day, andcertainly avoid application in direct sunlight.
Nitocote® ET402
iv For hand application, ensure that there are sufficientoperatives available to complete application within the potlife of the material.
v Have a ready supply of Fosroc Solvent 102 available forimmediate cleaning of tools after use.
Repairing and overcoating
Any applications of Nitocote ET402 which have becomedamaged can be readily overcoated.
The existing surface should well abraded, using a stiff wirebrush, or similar, to ensure that a good mechanical bond willbe achieved between the two layers.
Overcoating works can then proceed as for new work, alwaysensuring that the prepared substrate is free from anymoisture.
Limitations
Nitocote ET402 should not be applied over other existingcoatings, but can be applied on top of itself (see above).
For cold weather working (down to 5°C), it is recommendedthat materials are stored in a heated building and onlyremoved immediately before use.
Accelerated heatingmethods are not to be utilised underany circumstances.
- In contact with moisture/high humidity during cure, thecolour of the coatings will change to brown/red.
Estimating
Supply
Nitocote ET402 : 10 litre packsNitoprime 25 : 1 and 4 litre packsNitoflor Sol : 5 litre packs
Coverage
Nitocote ET402 : 5.0 m2/litre @ 200 microns wft (per coat)
Nitoprime 25 : 5.0 m2/litre
Note: Coverage figures quoted are theoretical, and basedupon application to a properly prepared substrate of nominalMC30 concrete. Since application conditions vary greatly; dueto substrate porosity, quality of surface preparation,application thickness and wastage factors, the on-site figuresmay vary from those shown above.
Storage
Nitocote ET402 has a shelf life of 12 months, when stored inwarehouse conditions below 35°C.
Precautions
Health and safety
Nitocote ET402, Nitoprime 25 and Nitoflor Sol shouldnotcome in contact with skin or eyes, nor should they beswallowed. Avoid inhalation of vapours and ensure adequateventilation. Some people are sensitive to resins, hardenersand solvents. Wear suitable protective clothing, gloves andeye/face protection. Barrier creams provide additional skinprotection. Should accidental skin contact occur, removeimmediately with a resin removing cream , Industrial SkinCleanser, followed by washing with soap and water - do notuse solvent. In case of contact with eyes, rinse immediatelywith plenty of water and seek medical advice. If swallowedseek medical attention immediately - do not induce vomiting.
For further information, please consult the Material SafetyData Sheet for Nitocote ET402.Fire
Nitocote ET402 and Nitomortar FC are non-flammable.Nitoprime 25 and Nitoflor Sol are flammable. Do not usenear a naked flame.
Flash points
Nitoprime 25 : 55°CNitoflor Sol : 33°C
Additional Information
Nitocote® ET402
INDIA/0777/A
Important note :Fosroc products are guaranteed against defective materials and manufacture and are sold subjectto its standard terms and conditions of sale, copies of which may be obtained on request. WhilstFosroc endeavours to ensure that any advice, recommendation specification or information it maygive is accurate and correct, it cannot, because it has no direct or continuous control over whereor how its products are applied, accept any liability either directly or indirectly arising from theuse of its products whether or not in accordance with any advice, specification, recommendationor information given by it.
telephone fax e-mail
++91 80-2334 3188 ++91 80-2334 3178 [email protected]
Fosroc Chemicals (India) Pvt. Ltd.Head Office‘Vishnu Chittam’, No. 10, 2nd FloorSirur Park B Street, SeshadripuramBangalore 560020www.fosroc.com
® Denotes the trademark of Fosroc International Limited
Regional OfficesBangalore Mumbai Delhi Kolkata‘Vishnu Chittam’, No.10, 1stFloor 208/209, Persepolis 109-113, 1st Floor, Vikrant Towers P-569, Lake Terrace Extn.Sirur Park B Street, Seshadripuram Sector 17, Vashi 4, Rajendra Place First FloorBangalore 560 020 Navi Mumbai 400 703 New Delhi 110 008 Kolkata 700 029Ph:080-2334 3188 Ph:022-2789 6411/12 Ph:011- 45062000-5 Ph: 033 24650917 / 55343188Fax : 080-23368667 Fax: 022 - 2789 6413 Fax: 011- 45062001 Fax: 033-24650891email: [email protected] email:[email protected] email:[email protected] email:[email protected]
Ahmedabad : (079) 26762799 Ankleshwar :(02646) 220704/224687 Bellary: 09845891690 Bhubaneshwar : (0674) 2521176 Chennai : (044) 24899949/24853383 Chandigarh : (0172) 2639360 Cochin : (0484) 2347465 Coimbatore : (0422) 2472966 Goa : (0832) 09423058696 Guwahati : (0361) 2462866 Hyderabad : (040) 27662324/27662425 Indore : (0731) 4049339 Jaipur : (0141) 2336103 Lucknow :(0522) 2239044 Nagpur: (0712) 2753510/2563242 Visakhapatnam : (0891) 2564850 / 2707607
Fosroc manufactures a wide range of complementaryproducts which include :
waterproofing membranes & waterstops
joint sealants & filler boards
cementitious & epoxy grouts
specialised flooring materials
Fosroc additionally offers a comprehensive package ofproducts specifically designed for the repair and
refurbishment of damaged concrete. Fosroc’s ‘SystematicApproach’ to concrete repair features the following :
hand-placed repair mortars
spray grade repair mortars
fluid micro-concretes
chemically resistant epoxy mortars
anti-carbonation/anti-chloride protective coatings
chemical and abrasion resistant coatings
For further information on any of the above, please consultyour local Fosroc office - as below.