NIR INTENSITY LENS · Radiant Vision Systems | A Konica Minolta Company Blue Gray Orange 1. Layouts...
Transcript of NIR INTENSITY LENS · Radiant Vision Systems | A Konica Minolta Company Blue Gray Orange 1. Layouts...
RadiantVisionSystems|AKonicaMinoltaCompany
Blue
Gray
STA
ND
ARD
CO
LOR P
ALE
TTE
Orange
1. Layouts should
use our three
standard colors
as the primary
palette in your
presentation.
Use on-screen
Eyedropper to
sample color
from here.
2. Stay within the
interior margin of
the slide layout. 3. Font usage will be Verdana for title/section headline and body text as the PPT standard. Thank you for your cooperation.
RadiantVisionSystems|AKonicaMinoltaCompany
NIR INTENSITY LENS MEASURING NEAR-INFRARED SOURCES QUICKLY & EASILY
2 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
TODAY’S TOPICS
• Measuring Near-Infrared Sources • NIR Intensity Lens
• Instant Measurements • Fine-Detail Resolution • Minimal Equipment • From R&D to Production
• TT-NIRI Software • Summary
3 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
COMMON APPLICATIONS Non-Visible 3D Sensing Used In…
Automotive LiDAR
Eye Tracking
Gesture Recognition
Facial Recognition
4 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
WHY MEASURE INFRARED INTENSITY?
• Does the device provide enough intensity for sensors to work correctly?
• Does the device provide too much light for the human eye to receive safely?
5 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
TYPES OF LIGHT SOURCES
• FLOOD • Light sources used in
Time of Flight (TOF) applications
• Structured Light • Laser light diffused
through Diffractive Optical Elements (DOE)
• Sometimes called a dot pattern
• LED, Laser, VSCEL
6 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
TRADITIONAL MEASUREMENT
• Goniometer: • Rotate source in front of a photodetector
or camera to capture intensity data at each angle
• Limitations: • Requires thousands of rotations of
source in front of an imager • Time consuming (1+ hours) • May leave gaps in measurement; cannot
measure structured light pattern
7 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
TRADITIONAL MEASUREMENT
Irradiance on a wall: • Cast dot pattern on a wall/screen and
measure with imaging system • Verify dot position against a target
pattern or defined coordinates • Simple pass/fail on pattern match
• Limitations: • Limited angular field of view • Requires relatively large projection screen • Resolution potentially reduced due to
diffusive screen material
NIR INTENSITY LENS For Near-Infrared Angular Emission Measurement
9 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
NEAR-INFRARED INTENSITY LENS SOLUTION
Fast, accurate, integrated lens solution for radiant intensity measurement of 930–950 nm emitting light sources
10 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
NIR Intensity Lens Integrated optical component
ProMetric® Y16 16-megapixel CCD radiometer
SOLUTION COMPONENTS
11 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
FOURIER OPTICS
12 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
IMAGING LENS VS. CONOSCOPE LENS Image Lens Conoscope Lens
• Measuring the spatial (position) distribution
• The lens creates an image that maps a distance on the object to a certain number of pixels on the image
• The image will closely resemble the object
• Measuring the angular distribution • The lens creates an image that maps
incoming angles to positions on the image
• The image will look like an image taken with a fisheye lens
13 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
LENS MECHANICS
All dimensions measured from flange for ease of set up.
14 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
3mm
4mm
940 nm, angular emissions to ±70°
116mm
15 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
INSTANT MEASUREMENTS
• Using Fourier optics, lens solutions captures a full cone of data in a single measurement
• No need to rotate photodetector or source (laser, LED) to capture distribution of angular light
16 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
FINE-DETAIL RESOLUTION
• Simultaneously measure all angles to ±70°
• Angular resolution to ~0.05° per CCD pixel
17 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
MINIMAL EQUIPMENT
• Traditional measurement set up
• Now replaced by: • Single camera/lens solution
• Compact & turnkey form factor
• Easily integrated with minimal setup and configuration
18 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
FROM R&D TO PRODUCTION
• Capture & compare measurement data to ensure development accuracy
• Characterize displays in the lab for engineering and development
• Use R&D data as benchmark during production for quality control
• Easily transition data files saved through common software environment
19 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
NIR INTENSITY LENS SOLUTION
• Single camera/lens solution • Measure lasers or LEDs emitting at 940 nm*
• Simultaneously measure all angles to ±70° • Angular resolution to ~0.05° per CCD pixel
• Working Distance = 3 mm • For light sources < 4.0 mm in diameter**
* Contact Radiant for applications at other wavelengths
** Contact Radiant for light sources > 4.0 mm in diameter
TrueTest™ TT-NIRI SOFTWARE Test Suite for NIR Intensity Lens System
21 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
TT-NIRI SOFTWARE
Pre-defined tests for evaluating near-IR emitters for: • Angular distribution • Radiant intensity • Uniformity, hot spots, fall-off • Statistics on structured light,
e.g., diffractive optical element (DOE) dot patterns
22 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
FULL SUITE OF TESTS INCLUDED IN TT-NIRI
23 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
ANGULAR DISTRIBUTION MEASUREMENT
Radar plot in TT-NIRI Software showing radiant intensity (as function of angle) of an infrared LED
24 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
FLOOD SOURCE ANALYSIS
• Analyze distributions: • Uniformity across angular
emissions (intensity at each degree)
• Center values • Angular fall-off • Hot-spots
25 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
DOE DOT SOURCE ANALYSIS
Software automatically defines points of interest
Before analysis After analysis
26 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
Points of interest for DOE dot source analysis ensure patterns are projected at correct angle (inclination, azimuth) and intensity (W/sr).
27 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
• Location in pixels (x,y)
• Location in inclination/ azimuth (degrees)
• Intensity (W/sr)
• Peak Average Intensity (mW/sr)
• Peak Solid Angle (sr)
• Pixels at Maximum Peak
• Spot Power Uniformity (%)
• Maximum Peak Radius (°)
• Total Flux (mW or W)
• DOE Flux (mW)
• Image Export
EXAMPLES OF TT-NIRI DATA OUTPUT
28 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
SUMMARY
! The NIR Intensity Lens instantly captures the angular distribution of a near-infrared emitter up to +/-70 degrees in a single measurement, without moving the camera or device.
! Radiant’s solutions offers the advantage of speed, size, and software for precise and efficient measurement.
! NIR measurement with a ProMetric camera/lens solution is faster and more efficient than traditional methods like goniometric solutions, with much higher resolution.
RadiantVisionSystems|AKonicaMinoltaCompany
Blue
Gray
STA
ND
ARD
CO
LOR P
ALE
TTE
Orange
1. Layouts should
use our three
standard colors
as the primary
palette in your
presentation.
Use on-screen
Eyedropper to
sample color
from here.
2. Stay within the
interior margin of
the slide layout. 3. Font usage will be Verdana for title/section headline and body text as the PPT standard. Thank you for your cooperation.
RadiantVisionSystems|AKonicaMinoltaCompanyQuestions? Contact [email protected]
THANK YOU!
30 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
EXTRA SLIDES
31 Radiant Vision Systems | A Konica Minolta Company
© Radiant Vision Systems, LLC
WHY 940 NM?
• H2O absorption band removes sun radiation at 940 nm, so that interference from sunlight (ambient light) will be reduced
• Not visible to human eye