NHP On Tour Townsville 2009 - Introduction to GuardLogix ... On Tour Townsville 2… · •...
Transcript of NHP On Tour Townsville 2009 - Introduction to GuardLogix ... On Tour Townsville 2… · •...
Integrated Safety
Session AgendaAgenda
Session AgendaIntroduction to GuardLogix – Approx 15min
Hands-on lab – Approx 1.5 hrs
Topics to CoverContents
Topics to CoverIntroduction to GuardLogix
GuardLogix with ControlLogix Functionality
GuardLogix with RSLogix 5000
Safety I/O
G d i K B fiGuardLogix Key Benefits
Topics to CoverContents
Topics to CoverIntroduction to GuardLogix
GuardLogix with ControlLogix Functionality
GuardLogix with RSLogix 5000
Safety I/O
G d i K B fiGuardLogix Key Benefits
Introduction to GuardLogix
1980s Today1980 y
Introduction to GuardLogixRSLogix 5000 SoftwareRSLogix 5000 Software • Function Block Diagram• Ladder Logicg• Structured Text• Sequential Function Chart • Certified Safety InstructionsIntegration with:• Motion
sequential control
process control
• Motion • Process • Safety
safety control
y• Drives control motion
controldrives control
Introduction to GuardLogixAS 62061AS 62061
SIL4
SIL3
SIL2 GuardLogix
sk
SIL1 ControlLogix GuardPLCSmartGuard 600R
is
NO SIL
Introduction to GuardLogix• High Performance Integrated Safety• Up through SIL 3 /Cat 4p g• Standard Logix – Rack, Power Supply and
Comms Modules• RSLogix 5000 Software• CIP Safety DeviceNet, ControlNet, EtherNet • Full Logix functionality + SIL 3 safety GuardLogix
• Packaged Safety Controllers• Up thru SIL 3 /Cat 4
• Full Logix functionality + SIL 3 safety
GuardPLC’s
g
• Up thru SIL 3 /Cat 4• High Performance• Discrete and Analog I/O• GuardPLC Ethernet & DeviceNet• Full IEC 1131 FB
C tifi d f t li ti i t tiS tG d 600 • Certified safety application instructions
• SmartGuard 600• Up through SIL 3 / Cat 4 programmable safety • 16 safety inputs / 8 safety outputs / 4 std outputs
SmartGuard 600
MSR300
• Safety Relays • Modular Expansion
MSR200
16 safety inputs / 8 safety outputs / 4 std outputs• Networked safety I/O expansion (CIP Safety on DeviceNet)
p• Configurable
Introduction to GuardLogix•• Ease of use and Integration impact 35% of system costsEase of use and Integration impact 35% of system costsg yg y•• Wiring and Installation costs are 45% of system costs.Wiring and Installation costs are 45% of system costs.
I/O and Controller I/O and Controller only 2%only 2% of of y %y %
total HARDWAREtotal HARDWAREsystem costsystem cost
2% 13%20%
HardwareComponentsEnclosures /C bi t
On Machine I/OOn Machine I/OWiring SystemsWiring Systems
5%
CabinentsHardware Eng
S ft D i
Wiring SystemsWiring SystemsRemovable TerminalsRemovable Terminals
20%
Software Design
Test & Documentation%
25%Installation
Inside Cabinet WiringEase of useEase of useFaceplates Faceplates 15% Inside Cabinet WiringFaceplates Faceplates
Certified InstructionsCertified InstructionsLogic toolsLogic tools
Device IntegrationDevice Integration
Introduction to GuardLogix
Centralized I/O Centralized I/O ArchitectureArchitecture Distributed I/O Distributed I/O
9% HardwareComponents
ArchitectureArchitecture2%
13%20%
7%
9%
11% ComponentsEnclosures /CabinentsHardware Eng
5%
23% Software Design
Test&Documentation
32%9%Installation
Inside Cabinet Wiring
20%25%
15%
Topics to CoverContents
Topics to CoverIntroduction to GuardLogix
GuardLogix with ControlLogix Functionality
GuardLogix with RSLogix 5000
Safety I/O
G d i K B fiGuardLogix Key Benefits
Topics to CoverContents
Topics to CoverIntroduction to GuardLogix
GuardLogix with ControlLogix Functionality
GuardLogix with RSLogix 5000
Safety I/O
G d i K B fiGuardLogix Key Benefits
GuardLogix with ControlLogix FunctionalitySt d d C t l d S f t C t l i t ll• Standard Control and Safety Control in one controller
• Standard Controllers and Safety Controllers in a common chassiscommon chassis
• Standard Control and Safety Control on common networksnetworks
GuardLogix with ControlLogix Functionality• Modular rack based communications
– EtherNet/IP, ControlNet™, DH+, RIO, DeviceNet ™ and EWEB EtherNet/IP
– Controller Serial ASCII, DF1, and DH485– Mix and match network interfaces
Add as many or as few networks as needed– Add as many or as few networks as needed• Flexible networking
– Bridging and routing between messaging ControlNetRIO, DH+
networks across backplane w/o processorintervention
• 3rd Party Networks via Encompass Partners
DeviceNet
y p
GuardLogix with ControlLogix FunctionalityContinuous Task Scan Periodic Task Scan
Tim
e-sli
ce
esta
rt
Program 2
Program 1
Program 2
Program 1
5ms10ms
15ms...
Event Task Scan
Program 2
Program 1
InputMotion
Code...
PU O
verh
ead
T
Task
Aut
o-re Program 2
Program n
...
Program 2
Program n
...
Program 2
Program n
...
• Executes each program top to bottom
CP
Scan interrupted byperiodic and event tasks
Program ..n Program ..n
Depending on task priorityscan interrupted by
other periodic and event tasks
Program ..n
Depending on task priorityscan interrupted by
other periodic and event tasksExecutes each program top to bottom and then restarts
• Operates at the lowest priority on the controllerUses all CPU time left after other tasks
• Triggered automatically at a preset time interval
• Interrupts lower priority tasks and can be interrupted by higher priority tasks
• Triggered on arrival of input, consumed tag, motion operations, via another program, or a Windows Event for SofLogix5800
p
• Uses all CPU time left after other tasks execute
• Interrupted by operating system to perform processor and
be interrupted by higher priority tasks (15 Levels)
• Will time-slice on a 1ms basis with another task at the same priority level
for SofLogix5800• Priority same options as Periodic...• Captures fault for task overlap• Similar to PLC Peripheral Input
communications overhead• Traditional PLC Scan
• Captures fault for task overlap• Similar to PLC/SLC Selectable Timed
Interrupt (STI)
Interrupt (PII) or SLC Discrete Input Interrupt (DII)
GuardLogix with ControlLogix Functionality• Safety Task is a Periodic Task Periodic Task Scan• Safety Task is a Periodic Task• Safety Task executes in the GuardLogix Primary (L61S L62S) and the GuardLogix
Periodic Task Scan
Program 2
Program 1.
5ms10ms
15ms...
Primary (L61S, L62S) and the GuardLogix Safety Partner (LSP)
• Safety Task results are crossProgram ..n
..
Safety Task results are cross checked by both controllers (primary >< partner)
• Triggered automatically at a preset time interval
• Interrupts lower priority tasks and can be interrupted by higher priority tasks (15
– When checks are done and OK, safety output data is written to the safety
g p y (Levels)
• Will time-slice on a 1ms basis with another task at the same priority levelC t f lt f t k loutputs • Captures fault for task overlap
• Similar to PLC/SLC Selectable Timed Interrupt (STI)
Guardlogix with ControlLogix Functionality
Language LD (Std Task) FBD (Std Task) SFC (Std Task) STX (Std Task) LD + (Safety Task)
Instructions Set • Boolean• General & Trig Math• Timer / Counters• Table / Array
management
• General & Trig Math• Timer / Counters • Bit wise Logical• Advanced Process Blocks
Ad d D i Bl k
• Step / Action with full embedded STX
• Transition with Embedded STX comparisons
• Simultaneous and Select
• General & Trig Math• Timer / Counters• Bit wise Logical• Table / Array
management
• Certified Safety Instructions
– Boolean– Compare– Math/Conversionmanagement
• Diagnostic• Serial Port & Messaging• ASCII Manipulation• Specialty CPU control• Motion control blocks
• Advanced Drive Blocks Simultaneous and Select Branch
• Stop Element
management• Diagnostic• Serial Port & Messaging• ASCII Manipulation• Specialty CPU control• Motion control blocks
– Move Logical– Program Control– Timer / Counters
• Certified Safety Application Instructions
• Advanced Process Blocks• Advanced Drive Blocks
Editor Style • Graphical rungs• Unlimited rungs
• Graphical free form drawing
• Unlimited sheets
• Graphical free form drawing
• Unlimited Grid space
• Textual• Unlimited lines
• Graphical rungs• Unlimited rungs
Upload / Download • Full upload/Download • Full upload/Download • Full upload/Download • Full upload/Download• Comments included
• Full upload/Download
Editing • On/Off line rung level edits
• On/Off line routine edits • On/Off line routine edits • On/Off line routine edits • On/Off line rung level edits
Monitoring • Rung animationD l i i
• Output pin data value animation
• Active Step(s) AnimationA Di l S ll
• Tag watch paneC l i
• Rung animationD l i i• Data value animation
• Force statusanimation • Auto Display Scroll
• Branch/ trans force status• Context coloring • Data value animation
• Force status
Comments • Tag and Rung • Tag, Text Boxes • Tag, Text Boxes, and Embedded ST comments
• Multi-line and end of line embedded in text
• Tag and Rung
GuardLogix with ControlLogix Functionality
• ControlLogix Integrated SafetyGuardGuardLogixLogix
• ControlLogix Integrated Safety– Dual Processor Solution (1oo2 Architecture)
SIL 3 Certification per AS 62061– SIL-3 Certification per AS 62061– AS 4024 Category 4
P ith RSL i 5000– Programs with RSLogix5000– CIP Safety I/O on EtherNet or DeviceNet
Topics to CoverContents
Topics to CoverIntroduction to GuardLogix
GuardLogix with ControlLogix Functionality
GuardLogix with RSLogix 5000
Safety I/O
G d i K B fiGuardLogix Key Benefits
Topics to CoverContents
Topics to CoverIntroduction to GuardLogix
GuardLogix with ControlLogix Functionality
GuardLogix with RSLogix 5000
Safety I/O
G d i K B fiGuardLogix Key Benefits
GuardLogix with RSLogix 5000G ardLogi Controllers in • GuardLogix Controllers in Selection Dialog
– 1756-L61S– 1756-L61S– 1756-L63S
• Safety Partner Automatically • Safety Partner Automatically Assigned to the next Slot - Right of the Safety Controller– 1756-LSP
GuardLogix with RSLogix 5000
• RSLogix5000– Safety Task automatically created with tools that restrict y y
user to Safety functions– Single controller view
• Standard Control Task(s)– Same functionality that exists today with ControlLogix
(V16)
• Safety Control - Safety Task– Restricted set of features and functionsRestricted set of features and functions– Safety Certified Standard Instructions– Safety Certified Application Instructions– Security (Safety Task Signature, Locking)– Safety I/O automatically mapped into safety memory
Guardlogix with RSLogix 5000• Safety
Controller Status
• Safety Instruction P l ttPalette
• Periodic SafetyPeriodic Safety Task
• Routine Information Box with Class
• Watermark
GuardLogix with RSLogix 5000
GuardLogix with RSLogix 5000• 49 Safety Certified Instructions49 Safety Certified Instructions
– Subset of standard ladder logic instruction set
• Safety Certified Application Instructions– Dual Channel Suite
• 6 Instructions– Metal Forming Suite
• 10 Instructions– Muting Suite
GuardLogix with RSLogix 5000
P id th• Provides the same functionality as:– 16 rungs of logic– 16 rungs of logic
• 2 Timers• 5 Latching coils• 3 One shots
• ResultsSignificant reduction in– Significant reduction in memory usage
– Much easier maintenance
GuardLogix with RSLogix 5000• Safety Task operates in 1 of 2 statesy p
– Standard behavior (Safety signature does not exist)– SIL 3 Safety behavior (Safety signature exists)y ( y g )
• Safety Task - Standard– User actions same as standard task
Forcing online editing memory write are allowed– Forcing, online editing, memory write are allowed.
• Safety Task - Safety– Safety Logic and data is protected– NO FORCES– NO ONLINE EDITING– SAFETY MEMORY READ ONLY
• Safety Signature– A 64 bit unique number
• Calculated by GuardLogix Firmware
Topics to CoverContents
Topics to CoverIntroduction to GuardLogix
GuardLogix with ControlLogix Functionality
GuardLogix with RSLogix 5000
Safety I/O
G d i K B fiGuardLogix Key Benefits
Topics to CoverContents
Topics to CoverIntroduction to GuardLogix
GuardLogix with ControlLogix Functionality
GuardLogix with RSLogix 5000
Safety I/O
G d i K B fiGuardLogix Key Benefits
Safety I/OSafety modules appear• Safety modules appear directly on the I/O Config Tree within RSLogix 5000g– DeviceNet Safety I/O
looks like I/O on ControlNet or EtherNetControlNet or EtherNet I/P
• Safety tags areSafety tags are automatically created
• Safety module configuration is owned by GuardLogix.
Safety IOSIL 3 & Category 4 Certified for use, by TUV UL Listed for Functional Safety -
NRGF.E256621
Key Features
Safety I/OKey Features
Configurable Standard Outputs, Removable terminal blocks,DIN Rail mountable
Product CharacteristicsConfigurable Standard Outputs
• Use for standard control• Use for standard control • Use as an input’s pulse test source
Safety I/O
Safety I/O• Eliminate need for IO panels• Eliminate need for IO panels• Simplify design/installation time using devices with quick
disconnectdisconnect• Many safety devices directly connect to ArmorBlock Guard
I/O
Safety I/O• CompactBlockTM Guard I/OTMCompactBlock Guard I/O• Same as new 1791DS DeviceNet CompactBlock Guard
IO productsBi P l O t t ti– Bi-Polar Outputs option
• Ethernet/IP Support– Set node number with software or rotary switchesSet node number with software or rotary switches
• IP20 Products:– #1 - 1791ES-IB8XOBV4 - 8 inputs, 4 Bipolar
8 l / d doutputs, + 8 pulse test / standard outputs– #2 – 1791ES-IB16 - 16 inputs, 0 outputs, +
16 pulse test / standard outputs• CIP Safety Guard I/O Modules on
EtherNet/IP supported in RSLogix 5000 V16
Safety I/O
RSLogixRSView
GuardLogix
GuardLogix
GuardLogix
SmartGuard 600SmartGuard 600
CIP Safety – EtherNet I/PCIP Safety – EtherNet I/PCIP Safety – ControlNetCIP Safety – DeviceNet
Topics to CoverContents
Topics to CoverIntroduction to GuardLogix
GuardLogix with ControlLogix Functionality
GuardLogix with RSLogix 5000
Safety I/O
G d i K B fiGuardLogix Key Benefits
Topics to CoverContents
Topics to CoverIntroduction to GuardLogix
GuardLogix with ControlLogix Functionality
GuardLogix with RSLogix 5000
Safety I/O
G dL i K B fiGuardLogix Key Benefits
GuardLogix Key BenefitsOne Single Programming Environment for DiscreteOne Single Programming Environment for Discrete, Motion, Drives, Safety, and Process
“Pure Tag-based” Control Environment
B tt I t t d M ti S f t d D iBetter Integrated Motion, Safety, and Drives
Better Integrated Ethernet SolutionBetter Integrated Ethernet Solution
GuardLogix Key Benefits• Safety and Standard One Project• Safety and Standard, One Project
– Upload / Download one project (including safety task)– Safety Data available to Standard Task (Read Only)y ( y)– Passing of Standard Data to Safety Task– Leverage existing hardware
• Chassis Power Supplies Comm’s etc• Chassis, Power Supplies, Comm s, etc.
• SIL 3 Safety Task– Certified Safety and Safety Application Instructionsy y pp
• Ladder Programming– SIL 3 Compact Block Safety I/O on DeviceNet Safety
O li Off li Editi d F i ( h U l k d)– On-line, Off-line Editing and Forcing (when Unlocked)– On-line Program Monitoring (Locked or Unlocked)– Safety Tags provide data security
4
Topics to CoverContents
Topics to CoverIntroduction to GuardLogix
GuardLogix with ControlLogix Functionality
GuardLogix with RSLogix 5000
Safety I/O
G dL i K B fiGuardLogix Key Benefits
Safety Resources @ Rockwell• Web ResourcesWeb Resources
– CIP Safety Overviewwww.odva.orgWhit P S f t N t k– White Paper - Safety Networkswww.odva.org/10_2/CIPWhite_paper_English.pdf
– Rockwell Automation Safety Certificationsk ll i / d / ifi i / f /www.rockwellautomation.com/products/certification/safety/
– Safety Home Pagewww.ab.com/safety
– Safety Librarywww.ab.com/safety (left navigator – click on Safety Library)
• Collateral• Collateral– Safety Now – new February 2006 issue
Order Publication No. SAFETY-BR001D-EN-PS f t O i B h till i t k– Safety Overview Brochure – still in stockOrder Publication No. SAFETY-BR008A-EN-P
Questions
??????????????