NFPA 99 Health Care Facilities Cross-Reference to the Changes in Medical Gas and Vacuum Systems (Chapter 4) from the 1996 to 1999 Editions Mark Allen, Editor BEACON MEDICAL PRODUCTS Continuing Education Publication

Transcript of NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care...

Page 1: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

NFPA 99Health Care Facilities

Cross-Reference to the Changes in Medical Gas andVacuum Systems (Chapter 4) from the 1996 to1999 Editions

Mark Allen, Editor

BEACONMEDICAL PRODUCTS

Continuing Education Publication

Page 2: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

Changes NFPA 99 1996 to 1999, Chapter 4 2

Notes on Using this Pamphlet:This pamphlet is presented as a service to users of the National Fire Protection Association’s Standardfor Healthcare Facilities, the NFPA 99. The pamphlet seeks to simplify understanding the changeswhich have occurred between the document as published in 1996 and the document as published in1999.

Users are cautioned that this pamphlet is intended to be used in conjuction with the standard, whichshould be obtained from:

National Fire Protection Association1 Batterymarch ParkQuincy, MA 02269-9101Phone 1-800-344-3555Internet www.NFPA.org

This pamphlet is not intended to be exhaustive and there may be changes of significance omitted fromthis document.

This pamphlet is not a publication of the National Fire Protection Association. Any opinionsexpressed and/or interpretations given or implied are the sole responsibility of Beacon Medical andthe editor, and should not be relied upon without reference to the standard.

This edition 6 March 2000Previous edition 6 August 1999

There is available an electronic version of this document in Adobe Acrobat (PDF) format. If you wouldlike to receive the document in that format, please e-mail [email protected] and indicateyou would like an electronic version of the ‘99 Changes booklet.

Notes

This Pamphlet in both print and electronic versions is Copyright 1999 Beacon Medical Products and Mark Allen. All Rightsare Reserved, and no reproduction may be made of the whole or any part without permission in writing. Distribution of theElectronic version is permitted only where the whole is transmitted without alteration, including this notice.

Comments on this booklet or on any aspect of medical gases are welcome andencouraged. Please send to [email protected]

Page 3: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

3 Changes NFPA 99 1996 to 1999, Chapter 4

Contents

Table of Contents

A Quick Overview of Major Changes ….… 4

The Quick Overview is intended to help thereader to gain an appreciation for the moresubstantial technical changes.

A Discussion on Levels …………………… 7

The Discussion on Levels is intended to helpunderstand this complex initiative and to givesome practical guidance on how to apply theLevels.

A Cross Reference between Editions ….… 8

The Cross Reference is intended to allow aparagraph by paragraph comparison of the twodocuments.

Page 4: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

Changes NFPA 99 1996 to 1999, Chapter 4 4

Major Changes

Notes on Major Changes

Introduction:The NFPA 99 1999 revision of Chapter 4 defi-nitely has fewer significant technical changes thanhave many previous editions. This said, the 1999revision is undoubtedly one of the more signifi-cant in the history of the standard. The mostsignificant changes are found not in Chapter 4but in the parts of the standard which determinehow Chapter 4 is applied - in Chapters 12 to 20,the occupancy chapters. In the changes to theseoccupancy chapters, we are seeing the furtherworking out of the “Levels” strategy first hinted atin the 1996 edition, and which will be a corner-stone of the standard for years into the future.(see the discussion on Levels which follows)

Within Chapter 4, a first pass review will revealthat the sections for Level 2 - marked “Reserved”in the 1996 edition now are fleshed out, there areseveral revisions to diagrams, there are some newdiagrams, and there is a remarkable amount oftext marked as changed by the line to the left.(The changed text marked by the lines is notnecessarily changed. Some has merely beenreorganized, and unfortunately there are realchanges which are not indicated. The lines arenot very useful.)

There are two currents which will be noted in thechanges: a continuing effort to make the bookmore “user friendly” offset by a concern that thebook’s user friendly features are being abused,leading to a need to tighten up, especially asregards Figures and Tables.

Changes - General:• Laboratories are more fully included in thescope of the chapter. That is, there are nowfewer cases where laboratories are not covered.(see Definition of Laboratory)

• Waste Anesthetic Gas Disposal now has anofficial name - “Waste Anesthetic Gas Disposal”or “WAGD”. This name will replace “evacua-tion”, “scavenging”, etc. WAGD is now officiallywithin the scope of Chapter 4, ending a longand acrimonious debate on whether it belongsto Chapter 5 as an Environmental System orChapter 4 as a piped medical gas system. (see4-1.1 Scope)

• The recommended Vacuum sizing methodol-ogy which has been in the Appendix since theincorporation of NFPA 56K into the NFPA 99,has been restored and moved into Appendix C.(see C-4.3)

• A new document, the CGA E-10 “Recom-mended Practice for Maintenance of MedicalGas and Vacuum Systems in Healthcare Facili-ties” has been included in the references. (seeB-1.2.6)

Changes - Level 1 Systems:• Where a manifold room opens onto an egresscorridor (see NFPA 101) mechanical ventilationis required. (see 4-3.1.1.2(c))

• A new Figure 4-3.1.1.8(h) has been brokenout of the old Figure 4-3.1.2 to more com-pletely illustrate the Emergency Oxygen Con-nection. (see Figure 4-3.1.1.8(h)

• Figure 4-3.1.1.9 has been dramaticallychanged. This was felt to be one of the mostabused figures in the book, and has beenchanged to reflect the text more exactly, as wellas to guide the user to the appropriate text.(note that some users have reported incorrectparagraph references).

Page 5: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

5 Changes NFPA 99 1996 to 1999, Chapter 4

Major Changes

Illustration #1Alarms for Medical Air Compressor Sources

Note: What is illustrated here is the minimum permitted by the standard.Many users prefer more comprehensive alarm arrangements.

There are additional safety devices required as well.

High Carbon Monoxide

High Water Level in Receiver

High Discharge Temperature

Lag Compressor in Use

High Dew Point

Compressor Fault

High Dew Point

Compressor Fault

High Dew Point

Compressor Fault

High Dew Point

High Carbon Monoxide

High Water Level in Receiver

High Water Level In Separator

Lag Compressor in Use

High Dew Point

Oil Less/Oil Free Compressor Types Liquid Ring Compressor Types

Loca

l Ala

rm

(at

Com

pres

sor)

Loca

l Ala

rm

(at

Com

pres

sor)

Mas

ter A

larm

#2

Loc

atio

n

Mas

ter A

larm

#1

Loc

atio

nM

aste

r Ala

rm#

2 L

ocat

ion

Mas

ter A

larm

#1

Loc

atio

n

Compressor Fault

High Dew Point

Page 6: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

Changes NFPA 99 1996 to 1999, Chapter 4 6

The figure should be used as a graphical tableof contents, to find the relevant text. It is notand never was intended to be used by itself.(see Figure 4-3.1.1.9)

• A point of confusion regarding alarms onmedical air systems has been resolved: Certainoperating alarms are now allowed to be relayedto the master alarms as a “Compressor Fault”signal in lieu of having individual indicators.(see Illustration 1 overleaf)

• Two alternate methods of piping air acces-sory items are explicitly permitted. (see 4-3.1.1.9 (h) and Figures 4-3.1.1.9 (h)1 and 4-3.1.1.9 (h)2

• There is a new Table 4-3.1.2.4 includingthree important pieces of information:

First, it eliminates the need to reference aseparate Compressed Gas Association docu-ment for color coding and symbology.

Second, it provides a listing of “StandardPressures” for reference when considering theparagraphs on “Nonstandard Pressures” (4-3.1.2.11).

Third, it provides a color coding scheme fornon-medical air and non-medical vacuum(practically, these will be found most useful forLevel 3 installations) and for Laboratory Airand Laboratory Vacuum.(see Table 4-3.1.2.4)

• There is no longer any allowance for brazersto be qualified on site - they must qualify in thesame manner and by the same tests in all cases.

• In the 1996 edition, when corrections wereperformed prior to verification, the verifier wasrequired to report these corrections. This is nolonger true. (see 4-3.4.1.1)

Major Changes

• Table 4-3.4.1.4 has been completely re-worked - it is now much more comprehensive.(see Table 4-3.4.1.4)

• Three changes of note have been made in thetesting arena:First: when a failure occurs in the requiredparticulate testing of 25% of all zones, allzones (100%) must then be tested. (see 4-3.4.1.3(e)Second: Some tests previously mandated to beperformed with nitrogen may now be done withsource gas. (see 4-3.4.1.3)Third: A transient flow test has been added foroxygen and air outlets (see 4-3.4.1.3(h)6)

Changes - Level 2 Systems:• This section, marked “Reserved” in the 1996edition has been fleshed out to include a wholeseries of requirements, largely borrowed di-rectly from the equivalent section in Level 1.(see 4-4)See the Section on “A Discussion of Levels” inthis pamphlet for more details.

Changes - Level 3 Systems:• Editorially, the paragraph references in the1996 edition have been replaced with theactual text in this edition.A number of changes have occurred in thisprocess. Among them:- The prohibition on flexible connectors inpatient systems (see 4-3.1.2.9(h) incorpo-rated by reference in 1996 was not included inthe 1999. Interesting enough, this prohibitiondoes exist for Gas Powered Device gas systems.- testing for soft tubing buried in slabs nowfollows the same rules as any other tubing.- flared fittings are permitted only at outletsand manifolds where exposed.- 95-5 solder may no longer be used on GasPowered Device gas systems. (see 4-5.1.3.1(c))- a paragraph “grandfathering” older PipedPatient gas systems has been added. (see 4-5.4.1.1)

Page 7: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

7 Changes NFPA 99 1996 to 1999, Chapter 4

About Levels

A Discussion on Levels

Introduction:The NFPA 99 1999 greatly extends the Levelsinitiative NFPA started with the 1996 edition. Thisinitiative began a proposal made for the 1996edition which involved changing the requirementsfor medical gas systems based on the complexity ofthe procedures intended to be performed there.

This proposal was not incorporated into the 1996edition due to it’s sweeping implications and thewide effect it would have in other areas of thestandard. However, pieces of it did enter the codeand can be seen in the exceptions found in Chapters12-19, for example in NFPA 99 1996 13-3.4.1

“If installed, patient gas systems shall conform to Level1 gas systems of Chapter 4.

A single alarm panel, as described in 4-4.3.1.2.1(b)2shall be mounted in an area of continuous surveillancewhile the facility is in operation.

Exception No. 1: Medical air compressors shall bepermitted to be simplex.

Exception No. 2: Dryers, after-coolers, filters, andregulators, as listed in 4-3.1.1.9 (g) shall be permittedto be simplex.

Exception No. 3: One alarm panel that complies with 4-3.1.2.1(b)3a,b,c and d and with 4-3.1.2.1(c)2 and5 shall be permitted.

Exception No. 4: Pressure switches shall be mounted atthe source with a pressure gauge or readout located atthe master alarm panel.”

These exceptions in the 1996 standard all derivefrom the original proposal for “Level 2”.

The underlying concept of less complex systems forless dependant patient populations continued todrive the thinking as the 1999 was in preparation.The 1999 reflects the next iteration in this process.Thus the sections on Level 2 no longer say simply“Reserved” as placeholders for something in the

future, Level 3 now no longer references Level 1but is nearly stand-alone, and the occupancychapters (12-20) now contain the beginnings of a“decision tree”, helping choose which Level appliesin a given facility.

The eventual goal is to be able to provide anappropriate level of medical gases (and ultimatelyother systems as well, eg. essential electricalsystems) based on the procedures done in thatfacility, not the name over the door. This is aresponse to the simple fact that in today’shealthcare environment the name over the door isbecoming less and less meaningful.

The levels program explicitly throws theresponsibility for a crucial decision back on theowner (where it always has belonged) However, afact of today’s healthcare environment is that someowners are uncomfortably willing to cut corners tosave a few dollars. The Levels program thereforeopens an opportunity to the owner who is willingto trade risk for money. It is the resultant risk topatients which is the weakness of the plan.

Compounding this potential problem is the simplefact that the decision trees as now written aresimplistic, incomplete and difficult to interpret.There is no additional guidance on how to fit specificcases.

Overall, Beacon recommends, except where theowner requires a specific level (and is thereforewilling to accept the consequences of that decision)that only Level 1 be used as a basis for design.

As NFPA refines the decision trees in the 2002edition edition and beyond, expect the Levels tobecome more useful and eventually to be thestarting point in any med gas design process.

Page 8: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

Changes NFPA 99 1996 to 1999, Chapter 4 8

Cross Reference

1-6 OrganizationSection 1-6 contains notes on using the documentand on it’s history.

Definition of Laboratory ;The definition for laboratory contains exclusions forsection laboratories and labs in which oxygen isadministered (eg. pulmonary function labs), and undersome circumstances blood donor rooms, and clinicalservice areas.

Definition of Nitrogen, Oil Free, Dry (Nitrogen forTesting and System Operation) :This gas is required to be CGA Grade M.

4-1.1 Chapter 4 Scope

4-3.1.1.2(a) (10) (b) Gas Storage FacilitiesOutdoor gas storage adjacent to a wall is requiredto be 25 feet from any opening in the building.4-3.1.1.2(c) Storage Locations (<3000 ft3)opening onto Egress CorridorsSuch locations may be ventilated mechanically ornaturally.4-3.1.1.7(b)(2) Cylinder reservesA contents alarm is required on cylinder reserveswithout check valves.

A-1-2 This material has been moved to the Appendix.

Definition of Laboratory ;These exclusions are removed.

Definition of Nitrogen, Oil Free, Dry (Nitrogen forBrazing and Testing) :Nitrogen for these uses is Nitrogen NF. NFPA 99 nolonger includes “system operation” in the definition.What grade of gas the facility chooses to administer isoutside the scope of NFPA 99.

4-1.1 Chapter 4 ScopeWaste Anesthetic Gas Disposal is explicitly added tothe scope of Chapter 4.

A specific statement of why has been added in a list ofhazards enumerated in 4-2.4.

4-3.1.1.2(a) (10) (b)Gas Storage FacilitiesOutdoor gas storage adjacent to a wall is requiredto comply with NFPA 50 “Bulk Oxygen Systems atConsumer Sites”4-3.1.1.2(c) Storage Locations (<3000 ft3)opening onto Egress CorridorsMechanical ventilation is required and naturalventing is not to be used.4-3.1.1.7(b)(1) Cylinder reservesA contents alarm is always required on cylinderreserves.

4-3.1.1.8 Oxygen and Medical Air are only for use in

KeyText in Green indicates additions (new material) added to this editionText in Red indicates material deleted from this editionText in Blue indicates text which has changed. Requirements are generally the same.Text in Magenta indicates text which has been rewritten for clarity.

1996 1999

Page 9: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

9 Changes NFPA 99 1996 to 1999, Chapter 4

Cross Reference

4-3.1.1.8(e) Venting of Relief ValvesRelief valves must be vented to the outside if thetotal capacity is 3,000 ft3 or greater.

4-3.1.1.8(h) Emergency Oxygen InletWhen the oxygen supply is located remote from thebuilding, the Emergency Low Pressure GaseousOxygen Inlet is required.

Fig. 4-3.1.1.9 Medical Air FigureA schematic of a Level 1 medical air system.

Level 1 Distribution requirements (4-3.1.2)

patient care. The placement of this paragraph (in thesection on manifolds and bulk supply systems) for thefirst time includes oxygen and medical air suppliedfrom these sources in this exclusion.

4-3.1.1.8(e) Venting of Relief ValvesRelief valves must always be vented to the outsideexcept for medical air, which must be vented only ifthe total capacity is 3,000 ft3 or greater.4-3.1.1.8(h) Emergency Oxygen InletWhen the cryogenic oxygen supply is locatedremote from the building, the Emergency LowPressure Gaseous Oxygen Inlet is required. Aswritten, manifold supply is excluded.

The connection must be accessible to emergencysupply vehicles and must be located on the buildingitself (eg. it cannot be at the oxygen supply site).

A new diagram (4-3.1.1.8(h)) shows the arrange-ment of the connection.

Fig. 4-3.1.1.9 Medical Air FigureA representation of a Level 1 medical air system.Note the paragraph references. This Figure is notintended to stand alone but is intended to be usedin conjunction with the text as referenced.4-3.1.1.9(h)1 Dryers, Filters and RegulatorsThis section has been consolidated from othersections in order to make the intent of the require-ments more clear. The new figures 4-3.1.1.9(h)1and 4-3.1.1.9(h)2 illustrate two alternate means ofproviding isolation valving.4-3.1.1.9(i)3 Compressor RequirementsSection 3 has been broken out more clearly as arequirement for all compressors.4-3.1.1.9(i)3 CO/Dewpoint AlarmsCO Alarms must be in the local alarm at thecompressor site and relayed to the master throughthe “Compressor Fault” indicator. Dew Point alarmsmust be in the local alarm at the compressor siteand relayed to each master alarm as a separatesignal. (see Illustration #1) (see also 4-3.1.2.2(b)3(g))

Level 1 Distribution requirements (4-3.1.2)This section has been extensively rearranged. A guideto this rearrangement appears in the very back of the99 book behind the index. (note : this guide does notappear in the 99 C extract)

Page 10: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

Changes NFPA 99 1996 to 1999, Chapter 4 10

4-3.1.2.3(a)

4-.1.2.3(a)24-3.1.2.1Demand checks are required for each switch orsensor. (4-3.1.2.1(a)6)Wiring must be in conduit (4-3.1.2.1(a)8)

4-3.1.2.24-3.1.2.2 (b)1 valve boxes4-3.1.2.2(b) Gas Shut off Valves4-3.1.2.2(b)2 Source valve4-3.1.2.2(b)3 Main Valves4-3.1.2.2(b)4 Riser Valves4-3.1.2.2(b)5 Zone Valves

4-3.1.2.2(b)6 Service Valves Note : 4-3.1.2.2(b)9 is a partial duplication.4-3.1.2.2(b)6 In Line Valves4-3.1.2.2(b)7 Valve Types4-3.1.2.2(b)8 Valve Location4-3.1.2.2(b)10 Flammable Gases4-3.1.2.2(d)4 ¶ 2 Required valves4-3.1.2.2(d)5 Critical Care4-3.1.2.2(d)6 Anesthetizing Locations4-3.1.2.2(d) Station Outlets4-3.1.2.2(c) Surface Mounted Medical Gas RailSystems

4-3.1.2.3(b) Installer Qualifications4-3.1.2.3(b)1(a) Qualification Tests4-3.1.2.3(b)2 Allowance for on-site Qualification

4-3.1.2.3(c) Brazed Joints4-3.1.2.3(c)1(b) Dissimilar metals can be brazedwith BCup or BAg series filler metal.

4-3.1.2.1(a)4-3.1.2.1(b)4-3.1.2.1(c)

4-3.1.2.24-3.1.2.2(a)6 Demand Chccks are required to begas specific.4-3.1.2.2(a)8 Wiring must be supervised orprotected as per the NFPA 70 National ElectricalCode, section 517-30.

4-3.1.2.74-3.1.2.3 valve boxes

4-3.1.2.3 Gas Shutoff Valves4-3.1.2.3(a) Source Valve4-3.1.2.3(b) Main Valves4-3.1.2.3(c) Riser Valves4-3.1.2.3(d) Zone Valves

term “branch line shutoff valves” has been changedto “zone valves”

4-3.1.2.3(j) Service Valves Note : 4-3.1.2.3(e) is a partial duplication.4-3.1.2.3(f) In Line Valves4-3.1.2.3(h) Shutoff valves {New or Replacement}4-3.1.2.3(i) Shutoff valves {Manual}4-3.1.2.3(k) Flammable Gases4-3.1.2.3(l) Required valves4-3.1.2.3(l) Critical Care4-3.1.2.3(m) Anesthetising Locations4-3.1.2.4 Station Outlets4-3.1.2.5 Surface Mounted Medical Gas Rail Systems

4-3.1.2.12 Installer Qualifications4-3.1.2.12(a) Qualification TestsMacroetching has been deleted as an acceptabletest.

On site qualification is no longer allowed.4-3.1.2.8(b) Brazed Joints ()4-3.1.2.8(b)1(b)Dissimilar metal must be brazed withBAg series filler metal. ()4-3.1.2.8(b)3 Cut tubing must be reamed.

Cross Reference

KeyText in Green indicates additions (new material) added to this editionText in Red indicates material deleted from this editionText in Blue indicates text which has changed. Requirements are generally the same.Text in Magenta indicates text which has been rewritten for clarity.

1996 1999

Page 11: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

11 Changes NFPA 99 1996 to 1999, Chapter 4

4-3.1.2.3(d) Threaded Joints

4-3.1.2.2(a) Gas Piping

4-3.1.2.2(a)6 sizing4-3.1.2.2(a)7 supports4-3.1.2.2(a)8 joints4-3.1.2.2(a)9 fittings4-3.1.2.2(a)10 turns4-3.1.2.2(a)11 protectionburied piping must be enclosed in a “continuoussplit enclosure”piping inside buildings but underground or inconcrete must be installed in conduit.4-3.1.2.2(a)12 risers4-3.1.2.2(a)13 kitchens/electrical switchgear4-3.1.2.2(a)14 other piping ()4-3.1.2.2(a)15 protection ()4-3.1.2.2(a)16 hoses and flex connectors4-3.1.2.2(a)16 conversion of use

4-3.1.2.2(c) Surface Mounted Rail Systems 4-3.1.2.2(c)1 4-3.1.2.2(c)2 4-3.1.2.2(c)3 4-3.1.2.2(c)4 4-3.1.2.2(c)5 4-3.1.2.2(c)6 4-3.1.2.2(c)7

4-3.1.2.2 Station Outlets Refers to CGA C-9 for color coding

4-3.1.2.2 (d) 4 ¶2, 5 & 6 4-3.1.2.2 (d) 7 4-3.1.2.2 (d) 8 4-3.1.2.2 (d) 9

4-3.1.2.2 (e) Manufactured Assemblies4-3.1.2.2 (e) 14-3.1.2.2 (e) 1 a4-3.1.2.2 (e) 1 b

4-3.1.2.8(a) Threaded JointsThreaded joints are permitted only for the connectionof devices such as pressure guages, switches, etc.

4-3.1.2.7 Piping MaterialsTubing is to be ASTM B-819,Type K or L.Tubing immediately attached to the outlet (outletpigtail) must be 3/8” OD.4-3.1.2.7 (d) Seismic bracing is required wherebuilding codes dictate.4-3.1.2.9 (a)4-3.1.2.9 (b)4-3.1.2.7 (g)4-3.1.2.7 (h)4-3.1.2.7 (i)4-3.1.2.9 (c)buried piping must be enclosed. The enclosureused must permit access during testing. Splitenclosures are one means. 4-3.1.2.9 (c) para.2deleted.4-3.1.2.9 (d)4-3.1.2.9 (e)4-3.1.2.9 (f)4-3.1.2.9 (g)4-3.1.2.9 (h)4-3.1.2.9 (i) Referenced and required paragraphsare changed. Added is requirement for Sources (4-3.1.2.1).

4-3.1.2.5 Surface Mounted Rail Systems 4-3.1.2.5(a) 4-3.1.2.5(b) 4-3.1.2.5(c) 4-3.1.2.5(d) 4-3.1.2.5(e) 4-3.1.2.5(f) 4-3.1.2.5(g)

4-3.1.2.4 Station OutletsNew Table 4-3.1.2.4 for color coding, standardpressures and symbology.

4-3.1.2.3 (l), (m), &(n) 4-3.1.2.4(e) 4-3.1.2.4(f) 4-3.1.2.4(g)

4-3.1.2.6 Manufactured Assemblies4-3.1.2.6 (a)4-3.1.2.6 (a) 14-3.1.2.6 (a) 2

Cross Reference

Page 12: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

Changes NFPA 99 1996 to 1999, Chapter 4 12

Cross Reference

KeyText in Green indicates additions (new material) added to this editionText in Red indicates material deleted from this editionText in Blue indicates text which has changed. Requirements are generally the same.Text in Magenta indicates text which has been rewritten for clarity.

1996 1999

4-3.1.2.2 (e) 1 c4-3.1.2.2 (e) 1 d4-3.1.2.2 (e) 1 e4-3.1.2.2 (e) 24-3.1.2.2 (e) 2 a4-3.1.2.2 (e) 2 b4-3.1.2.2 (e) 2 c

4-3.1.2.3 Installation Requirements

4-3.1.2.3(a) General

4-3.1.2.3(a) 1 Clean Materials4-3.1.2.3(a) 2 On Site Cleaning4-3.1.2.3(b) Qualification of Brazing Procedures

4-3.1.2.3(b)1 Basic requirement4-3.1.2.3(b)1a Qualification testQualification by sectioning, pull test ormacroetching of a test coupon4-3.1.2.3(b)1b4-3.1.2.3(b)1c4-3.1.2.3(b)1d4-3.1.2.3(b)1d i

4-3.1.2.3(b)1d ii4-3.1.2.3(b)1d iii4-3.1.2.3(b)1e4-3.1.2.3(b)1f4-3.1.2.3(b)2 On site qualification of Brazers

4-3.1.2.3(c) Brazed Joints4-3.1.2.3(c)14-3.1.2.3(c)24-3.1.2.3(c)34-3.1.2.3(c)44-3.1.2.3(c)54-3.1.2.3(c)6

4-3.1.2.6 (a) 34-3.1.2.6 (a) 44-3.1.2.6 (a) 54-3.1.2.6 (b)4-3.1.2.6 (b) 14-3.1.2.6 (b) 24-3.1.2.6 (b) 3

4-3.1.2.10 Installation RequirementsFirst sentence is deleted. Second sentence ismoved to 4-3.1.2.10 (a) 3Deleted, but see 4-3.1.2.7, 4-3.1.2.8 and 4-3.1.2.10

4-3.1.2.7(f)4-3.1.2.1 (c)4-3.1.2.12 Qualification of Brazing Procedures

4-3.1.2.12 (a) Macroetching is no longer anacceptable test.

4-3.1.2.12 (b)4-3.1.2.12 (c)4-3.1.2.12 (d)4-3.1.2.12 (d) 1 Procedures no longer can bequalified to ASME/ AWS but must meet NFPA 994-3.1.2.12 (d) 24-3.1.2.12 (d) 34-3.1.2.12 (e)4-3.1.2.12 (f)Section deleted - brazers can no longer be qualifiedon site.4-3.1.2.8 (b) Brazed Joints4-3.1.2.8 (b) 14-3.1.2.8 (b) 24-3.1.2.8 (b) 3 Reaming is now required4-3.1.2.8 (b) 44-3.1.2.8 (b) 5 (c)4-3.1.2.8 (b) 6

Page 13: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

13 Changes NFPA 99 1996 to 1999, Chapter 4

4-3.1.2.3(c)74-3.1.2.3(c)84-3.1.2.3(c)94-3.1.2.3(c)104-3.1.2.3(c)11 defective joints may be repairedtwice.

4-3.1.2.3(d) Threaded Joints

4-3.1.2.3(d)14-3.1.2.3(d)2

4-3.1.2.3 (e) Gas Piping System Installation4-3.1.2.3 (e) 14-3.1.2.3 (e) 2

4-3.1.2.3 (f) Prohibited Connections

4-3.1.2.4 Non Standard Operating Pressures4-3.1.2.4 (a)4-3.1.2.4 (b)4-3.1.2.4 (b)2

4-3.1.2.4 (c)4-3.1.2.4 (d)

4-3.2 Piped Vacuum Systems4-3.2.1 Source (Vacuum Pumps) Level 14-3.2.1.1 Multiple Pumps4-3.2.1.2 Backup Operation4-3.2.1.3 Alternation4-3.2.1.4 Motor Controls4-3.2.1.5 Electrical Power4-3.2.1.6 Receivers4-3.2.1.7 Piping4-3.2.1.8 Noise and Vibration4-3.2.1.9 Exhausts4-3.2.1.10 Typical Vacuum Source4-3.2.2 Distribution (Piping/Valving…)4-3.2.2.1 General4-3.2.2.2 Vacuum System Piping Network4-3.1.2.3(a)4-3.2.2.2(c)

4-3.1.2.8 (b) 74-3.1.2.8 (b) 84-3.1.2.8 (b) 94-3.1.2.8 (b) 104-3.1.2.8 (b) 11defective joints may be repairedonce.

4-3.1.2.8 (a) Threaded Joints4-3.1.2.8 (a) 1 Threaded Joints are limited toconnections for pressure guages, pressure switches,and similar4-3.1.2.8 (a) 24-3.1.2.8 (a) 3

4-3.1.2.10 Installation Requirements4-3.1.2.10(a) 14-3.1.2.10(a) 2

4-3.1.2.10(d) Wording changed

4-3.1.2.11 Non Standard Operating Pressures4-3.1.2.11(a)4-3.1.2.11(b)4-3.1.2.11(b)2 On site prohibition was madeuniversal4-3.1.2.11(c)4-3.1.2.11(d)

4-3.2 Piped Vacuum Systems4-3.2.1 Source (Vacuum Pumps) Level 14-3.2.1.1 Multiple Pumps4-3.2.1.2 Backup Operation4-3.2.1.3 Alternation4-3.2.1.4 Motor Controls4-3.2.1.5 Electrical Power4-3.2.1.6 Receivers4-3.2.1.7 Piping4-3.2.1.8 Noise and Vibration4-3.2.1.9 Exhausts4-3.2.1.10 Typical Vacuum Source4-3.2.2 Distribution (Piping/Valving…)4-3.2.2.1 General4-3.2.2.2 Vacuum System Piping Network4-3.2.2.2(a) Flux is allowed on vacuum4-3.2.2.2(c) Minimum pipe size is now 7/8” ODexcept for individual outlet drops which are now 5/8”OD, 0.5” ID and individual outlet pigtails which arenow 1/2” OD, 0.4” ID.

Cross Reference

Page 14: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

Changes NFPA 99 1996 to 1999, Chapter 4 14

Cross Reference

KeyText in Green indicates additions (new material) added to this editionText in Red indicates material deleted from this editionText in Blue indicates text which has changed. Requirements are generally the same.Text in Magenta indicates text which has been rewritten for clarity.

1996 1999

4-3.2.2.2(j) buried piping must be enclosed in a“continuous split enclosure”

4-3.2.2.3 Vacuum System Valve Boxes4-3.2.2.4 Vacuum System Valves not in Boxes4-3.2.2.5 Vacuum System Station Inlets4-3.2.2.6 Vacuum System Shut off Valves

4-3.1.2.3(a)

4-3.2.2.6(f) Section Valves4-3.2.2.7 Vacuum System Station Inlets

4-3.2.2.7(f)4-3.2.2.8 Master Alarm for Vacuum Systems

4-3.2.2.8 (a)4-3.2.2.9 Area Alarms for Vacuum Systems

4-3.2.2.9 (d)4-3.2.2.10 Vacuum System Gauges

4-3.2.2.10 (a)

4-3.2.2.11 Installation of Vacuum System Piping

4-3.3 WAGD Systems4-3.3.1 Source-Level 14-3.3.1.1 General4-3.3.1.2 Dedicated WAGD4-3.3.1.3 WAGD using Med-Surg Vacuum4-3.3.1.4 WAGD by Venturi

4-3.3.2 Distribution Level 1 WAGD4-3.3.2.1 WAGD Distribution Network4-3.3.2.2 WAGD Valves and Dampers

4-3.3.2.3 WAGD Inlets

4-3.3.2.4 WAGD Alarms4-3.3.2.5 WAGD Network Installation4-3.4 Performance Criteria and Testing - Level 1

4-3.2.2.2(j) buried piping must be enclosed. Theenclosure used must permit access during testing.Split enclosures are one means.4-3.2.2.3 Vacuum System Valve Boxes4-3.2.2.4 Vacuum System Valves not in Boxes4-3.2.2.5Vacuum System Station Inlets4-3.2.2.6 Vacuum System Shutoff Valves

4-3.2.2.6(a) Wording changed and meaningclarified.4-3.2.2.6(f) Service Valves

4-3.2.2.7 Vacuum System Station Inlets4-3.2.2.7(f) reworded

4-3.2.2.8 Master Alarm for Vacuum Systems4-3.2.2.8 (a) reworded

4-3.2.2.9 Area Alarms for Vacuum Systems4-3.2.2.9 (d) wording change

4-3.2.2.10 Vacuum System Gauges4-3.2.2.10 (a) Typo - change meant to reflectsituations where no main valve is installed.

4-3.2.2.11 Installation of Vacuum System Piping

4-3.3 WAGD Systems4-3.3.1 Source-Level 14-3.3.1.1 General4-3.3.1.2 Dedicated WAGD4-3.3.1.3 WAGD using Med-Surg Vacuum4-3.3.1.4 WAGD by Venturi

4-3.3.2 Distribution Level 1 WAGD4-3.3.2.1 WAGD Distribution Network4-3.3.2.2 WAGD Valves and Dampers Valves anddampers are to be installed where required -requirement has been strengthened.4-3.3.2.3 WAGD Inlets

WAGD Inlets are to be provided in any locationwhere nitrous oxide or halogenated agents are tobe administered.

4-3.3.2.3 WAGD Alarms4-3.3.2.5 WAGD Network Installation4-3.4 Performance Criteria and Testing - Level 1

Page 15: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

15 Changes NFPA 99 1996 to 1999, Chapter 4

4-3.4.1 Piped Gas Systems4-3.4.1.1 General

“certify” the system(s)4-3.4.1.1 ¶4 Test the entire system following abreach.

4-3.4.1.1 ¶5 Submit test reports documentingcorrections

4-3.4.1.2 Installer Testing Perform installer pressuretest with walls open.

4-3.4.1.2 (c) Standing Pressure Test4-3.4.1.2 (d) Piping Purge Test4-3.4.1.2 (e) Cross Connection Test

4-3.4.1.3 System Verification

4-3.4.1.3(e) Particulate test 25% of the zones

4-3.4.1.3(h)6

4-3.4.1.4 Source Equipment Verification4-3.4.1.4 (b) 2b Air quality test shall be“performed for a minimum of 24 hours”

Table 4-3.4.1.44-3.4.2 Piped Vacuum Systems - Level 14-3.4.2.1 Performance4-3.4.2.2 Testing

4-3.1.2.2(b)2 Standing Pressure Test Perform thistest with the walls open.4-3.1.2.2(b)2 Initial Cross-Connection Test

4-3.4.3 WAGD Systems4-3.4.3.14-3.4.3.2

4-3.4.1 Piped Gas Systems4-3.4.1.1 General

added temporary systems to this requirement“assure the facility by a documented procedure”4-3.4.1.1 ¶4 Testing after a “breach” of the systemno longer must involve the entire system, but nowmust only involve the system between the breachand the terminals.4-3.4.1.1 ¶5 Corrections no longer must bedocumented

General note on changes in the testing requirements:The testing requirements have been re-ordered toreflect general practice. Thus the test for the standingpressure test now follows the purge test instead ofpreceding it as in earlier editions.4-3.4.1.2 Installer Testing Perform installer pressuretest as convenient

4-3.4.1.2 (e) Standing Pressure Test4-3.4.1.2 (d) Piping Purge Test4-3.4.1.2 (c) Cross Connection Test

4-3.4.1.3 System Verification4-3.4.1.3¶3 In house installations may be testedby competent in-house personnel.4-3.4.1.3 ¶4 Exception: An allowance has beenmade for the performance of these tests withsource gas under some circumstances.4-3.4.1.3(e) Particulate test 25% of the zones, butif one fails, test 100% of the zones.4-3.4.1.3(h) 6 An additional criteria for Oxygenand air outlets flow has been added - a transientflow.4-3.4.1.3(h)7

4-3.4.1.4 Source Equipment Verification4-3.4.1.4 (b) 2b Air quality test shall beperformed after a minimum of 24 hours ofoperation.

Table 4-3.4.1.4 Table has been completely reworked4-3.4.2 Piped Vacuum Systems - Level 14-3.4.2.1 Performance4-3.4.2.2 Testing

4-3.4.2.2(b)4 Standing Pressure Test Perform thistest as convenient.4-3.4.2.2(b)3 Initial Cross-Connection Test4-3.4.2.2(c)5 Source Equipment Verification

4-3.4.3 WAGD Systems4-3.4.3.14-3.4.3.2

Cross Reference

Page 16: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

Changes NFPA 99 1996 to 1999, Chapter 4 16

Cross Reference

KeyText in Green indicates additions (new material) added to this editionText in Red indicates material deleted from this editionText in Blue indicates text which has changed. Requirements are generally the same.Text in Magenta indicates text which has been rewritten for clarity.

1996 1999

4-3.4.3.34-3.4.3.44-3.4.3.54-3.4.3.6

4-3.5 Administration - Level 14-3.5.1 Responsibility of Governing Body

4-3.5.2 Gas Systems Policies4-3.5.2.1 Gases in Cylinders and LiquefiedContainers - Level 14-3.5.2.1(b)25

4-3.5.2.2 Storage of Cylinders and Containers - Level14-3.5.2.3 Patient Gas Systems - Level 1

4-3.5.3 Gas Systems Recordkeeping - Level 1

4-3.5.4 Gas Systems Information and Warning Signs

4-3.5.5 Gas System Transport and Delivery - Level 1

4-3.5.6 Vacuum System Policies - Level 1

4-3.5.7 Vacuum System Recordkeeping - Level 1

4-3.5.8 Vacuum System Information and WarningSigns

4-3.5.9 WAGD System Policies - Level 1

4-4 Level 2Level 2 exists only as a “placeholder” in the 1996edition.

4-3.4.3.34-3.4.3.44-3.4.3.54-3.4.3.6

4-3.5 Administration - Level 14-3.5.1 Responsibility of Governing Body

4-3.5.2 Gas Systems Policies4-3.5.2.1 Gases in Cylinders and Liquified Containers- Level 1

4-3.5.2.1(b)25 An allowance has been made forsingle cylinders in use for immediate patient care.Such cylinders do not have to be kept inenclosures.

4-3.5.2.2 Storage of Cylinders and Containers -Level 14-3.5.2.3 Patient Gas Systems - Level 1

4-3.5.3 Gas Systems Recordkeeping - Level 1

4-3.5.4 Gas Systems Infomation and Warning Signs

4-3.5.5 Gas System Transport and Delivery - Level 1

4-3.5.6 Vacuum System Policies - Level 1

4-3.5.7 Vacuum System Recordkeeping - Level 1

4-3.5.8 Vacuum System Infomation and WarningSigns

4-3.5.9 WAGD System Policies - Level 1

4-4 Piped Gas Systems (Source and Distribution)Level 2

Level 2 is identical to Level 1 except:- Simplex compressors and air accessories arepermitted

Page 17: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

17 Changes NFPA 99 1996 to 1999, Chapter 4

4-5 Level 3 Piped Systems4-5.1 Piped Gas Systems (Source and Distribution)Level 34-5.1.1 Source - Level 34-5.1.1.1

Cylinders are to be treated as in Level 1 by refer-ence.

4-5.1.1.2 Source - Level 3Level 1 requirements apply by reference

Note on 4-3.1.1.2 (b) and (c) These sections in the1996 version are the sections often assumed to applyto “Level 3” installations. A careful reading will showthat all of the Level 1 requirements apply except forthe provision for locked gates (4-3.1.1.2 11 (c))

- A single master alarm is allowed.- Master alarms must be of the “Gauged” type.

4-4.2 Piped Vacuum SystemsLevel 2 is identical to Level 1 except simplex pumpsare permitted.

4-4.3 Piped WAGD SystemsLevel 2 is identical to Level 1 except simplexproducers are permitted.

4-4.4 Performance Criteria and Testing4-4.4.1 Piped Gases

As for Level 14-4.4.2 Piped Vacuum

As for Level 14-4.4.3 Piped WAGD

As for Level 1

4-4.5 Administration - Level 24-4.5.1 Responsibility of Governing Body

Reserved4-4.5.2 Piped Gases

As for Level 14-4.5.3 Piped Vacuum

As for Level 14-4.5.4 Piped WAGD

As for Level 1

4-5 Level 3 Piped Systems4-5.1 Piped Gas Systems (Source and Distribution)Level 34-5.1.1 Source - Level 34-5.1.1.1 Source - Level 3

The entire wording of Level 1 has been inserted.4-5.1.1.2 Source - Level 3

Entire section has been reworked. A careful readingwill reveal that few substantive changes haveoccurred, but many editorial changes have beenmade.4-5.1.1.2 (a) Only remote storage locations mustbe locked. Storage within the facility may or maynot be locked.4-5.1.1.2 (b)4-5.1.1.2 (b) 1 Allowance for louvered openingsin doors is retained except where doors open ontoegress corridors, (from 4-3.1.1.2 (c)) wheremechanical ventilation or ventilation to outside isrequired.4-5.1.1.2 (b) 2 New provision for sources of heat

Cross Reference

Page 18: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

Changes NFPA 99 1996 to 1999, Chapter 4 18

Cross Reference

KeyText in Green indicates additions (new material) added to this editionText in Red indicates material deleted from this editionText in Blue indicates text which has changed. Requirements are generally the same.Text in Magenta indicates text which has been rewritten for clarity.

1996 1999

in gas storage rooms. Other wording from Level 1has been inserted.4-5.1.1.2 (b) 3 The wording of 4-3.1.1.2 (a)2has been inserted.4-5.1.1.2 (b) 4-9 The wording of 4-3.1.1.2 (a)4-9 has been inserted.4-5.1.1.2 (b) 10 a-10c The wording of 4-3.1.1.2(a)10b-10d has been inserted.4-5.1.1.2 (b) 11a The wording of 4-3.1.1.2(a)11b has been inserted.4-5.1.1.2 (b) 11 b -11d The wording of 4-3.1.1.2(a)11e-g has been inserted.

4-5.1.1.3 Level 3Patient Gas Supply Systems4-5.1.1.4 Level 3Gas Powered Devices SupplySystems

4-5.1.2 Distribution for Patients - Level 34-5.1.2.14-5.1.2.24-5.1.2.34-5.1.2.44-5.1.2.54-5.1.2.64-5.1.2.74-5.1.2.8 Warning Systems4-5.1.2.8 (d) The wording for medical gas masteralarms (4-3.1.2.1 (b) 3e is inserted here. (par-tially redundant to 4-5.1.2.8 (a)), but adds the20% above and below operating pressure alarmrequirement.4-5.1.2.8 (e) Some wording changes4-5.1.2.9 Pressure GuagesGuages must be cleaned for oxygen service andmarked “Use No Oil”4-5.1.2.10 Gas PipingThe wording of 4-3.1.2.7 has been inserted withchanges.4-5.1.2.10 (a)3a When piping is installed in a slab,soft annealed tubing (ASTM B-88) may be used

4-5.1.1.3 Level 3 Patient Gas Supply Systems4-5.1.1.4 Level 3 Gas Powered Devices SupplySystems

4-5.1.2 Distribution for Patients - Level 34-5.1.2.14-5.1.2.24-5.1.2.34-5.1.2.44-5.1.2.54-5.1.2.64-5.1.2.74-5.1.2.8 Warning Systems

4-5.1.2.9 Pressure Gauges

4-5.1.2.10 Gas Piping4-3.1.2.2(a) is incorporated by reference

Except soft tubing (ASTM B-88) is allowed up to1/2” OD

Page 19: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

19 Changes NFPA 99 1996 to 1999, Chapter 4

(up to 1/2” OD)4-5.1.2.10 (a)3b The tube must pass through aconduit.4-5.1.2.10 (a)3c No joints may exist below theslab4-5.1.2.10 (a)3d Except that outlets may beinstalled after the tubing is run.4-5.1.2.10 (a)3e Testing is the same as forstandard pipe.4-5.1.2.10 (a)4 Flared fittings are limited tooutlets and manifolds where exposed.The limitation on flexible connectors is not presentin Level 3 systems4-5.1.2.10 (h)3 On site cleaning is allowed withlimitations in Level 3 Systems.4-5.1.2.11 Shutoff Valves4-5.1.2.11(b)4 Section 4-3.1.2.3 (c) is inserted4-5.1.2.12 Gas Station OutletsSection 4-3.1.2.4 is inserted with changes.Floor mounting provision is retained.Manufactured Assemblies may be connected usingDISS or noninterchangeable semi-permanentconnector.

4-5.1.3 Distribution for Gas Powered Devices Level 3Note on 4-5.1.3 - This section is intended for appli-cation to systems providing tool power. The require-ments are a subset of the requirements for patient gassystems reflecting the less critical intended use ofthese systems.

4-5.1.3.1(c) 95-5 Solder can no longer be used.4-5.1.3.1(d) inserted from 4-3.1.2.9 (b) in part.Section regarding details and spacing of hangersdoes not apply.4-5.1.3.1(e) inserted from 4-3.1.2.9 (c)4-5.1.3.1(f) inserted from 4-3.1.2.9 (f)4-5.1.3.1(g) inserted from 4-3.1.2.9 (g)4-5.1.3.1(h) inserted from 4-3.1.2.2 (a) 16

4-5.2 Piped Vacuum Systems - Level 34-5.2.1 Source4-5.2.2 Distribution

4-5.3 WAGD - Level 3

4-5.4 Performance Criteria and Testing - Level 34-5.4.1 Piped Patient Gas Systems4-5.4.1.1 General4-5.4.1.1 ¶3 New paragraph grandfathering existingsystems.4-5.4.1.3 System Verification and Final Testing

Except that flared fittings are permitted.

4-3.1.2.2(a)16 Limits the use of flexible connec-tors within a piping system.

4-5.1.2.11 Shut off ValvesSection 4-3.1.2.2 (b)4 is incorporated by refer-ence4-5.1.2.12 Gas Station OutletsSection 4-3.1.2.2(a) is incorporated by reference.

4-5.1.3 Distribution for Gas Powered Devices Level 3

4-5.1.3.1(c) joints may be brazed, soldered orthreaded.

4-5.2 Piped Vacuum Systems - Level 34-5.2.1 Source4-5.2.2 Distribution

4-5.3 WAGD - Level 3

4-5.4 Performance Criteria and Testing - Level 34-5.4.1 Piped Patient Gas Systems4-5.4.1.1 General

4-5.4.1.3 System Verification and Final Testing

Cross Reference

Page 20: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

Changes NFPA 99 1996 to 1999, Chapter 4 20

KeyText in Green indicates additions (new material) added to this editionText in Red indicates material deleted from this editionText in Blue indicates text which has changed. Requirements are generally the same.Text in Magenta indicates text which has been rewritten for clarity.

1996 1999

4-5.4.1.3 (c)

4-5.4.2 Piped Gas-Powered Devices Gas Systems

4-5.4.3 Piped Vacuum Systems

4-5.4.4 Piped WAGD

4.5.5 Administration - Level 34.5.5.1 Responsibility of Governing Body

4-5.5.2 Gas Systems Policies4-5.5.2.1 4-3.5.2.1 is incorporated by reference

4-5.5.2.2 4-3.5.2.2 is incorporated by reference

4-5.5.2.3 Patient Gas Systems - Level 34-5.5.2.3 (b) section exempts veterinary facilitiesfrom some provisions.4-5.5.2.3 (c) 4-3.1.1.3 is incorporated by reference.4-3.5.2.3 (c) is incorporated by reference.

4-5.5.2.3 (d)4-5.5.2.3 (e)4-5.5.2.3 (f)4-5.5.2.3 (g)

4-5.5.3 Gas System Recordkeeping - Level 3

4-5.4.1.3 (c) the wording of 4-3.4.1.2 (e) is insertedhere.4-5.4.2 Piped Gas-Powered Devices Gas Systems

4-5.4.3 Piped Vacuum Systems

4-5.4.4 Piped WAGD

4.5.5 Administration - Level 34.5.5.1 Responsibility of Governing Body

4-5.5.2 Gas Systems Policies4-5.5.2.1 4-3.5.2.1 is inserted here4-5.5.2.1 (c)2d Additional wording differentiatingbetween types of regulator is inserted here4-5.5.2.1 (c)2d or system is iadded noting thet theseprocedures apply to systems as well as apparatus4-5.5.2.2 4-3.5.2.2 is inserted here in part4-5.5.2.2 (a) The second sentence, dealing withanesthetising locations is removed. The third sen-tence dealing with fastening cylinders in storagelocations is removed. The fourth sentence dealingwith cylinders stored in anesthetising locations isremoved.The section from 4-3.5.2.2 (b)3 dealing with out-door storage of cylinders is removed4-5.5.2.3 Patient Gas Systems - Level 3Veterinary facilities have been excluded from thisstandard.4-5.5.2.3 (b) The text of 4-3.1.1.3 is inserted here.The text of 4-3.5.2.3 (c) is inserted here.4-5.5.2.3 (c) The text of 4-3.5.2.3 (c) is insertedhere.Paragraph deleted4-5.5.2.3 (d)4-5.5.2.3 (e)4-5.5.2.3 (f) The use of emergency shutoff vales andremote actuators for shutting down a system at theend of the day is specifically prohibited.4-5.5.3 Gas System Recordkeeping - Level 3

Cross Reference

Page 21: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

21 Changes NFPA 99 1996 to 1999, Chapter 4

4-5.5.4 Gas System Information and Warning Signs

4-5.5.5 text of 4-3.5.5 is inserted here.

4-5.5.6 Vacuum Systems Policies

4-5.5.7 Vacuum Systems Recordkeeping

4-5.5.8 Vacuum Systems Information and WarningSigns

4-5.5.9 WAGD Policies

4-6 Level 4 Piped Systems

4-6.1 Piped Gas Systems - Level 4

4-6.2 Piped Vacuum - Level 4

4-6.3 Piped WAGD - Level 4

4-6.4 Performance Criteria and Testing - Level 4

4-6.5 Administration - Level 4

Chapters 12-20 Occupancy Specific RequirementsSee the section on Major Changes for additionalinformation.Occupancies : Chapters 12 - 20

In the 1999 edition, Chapters 12 - 17 cover :12 : Hospitals13 : Other14 : reserved15 : reserved16 : Nursing Home17 : Limited Care Facilities18 : Home Care19 : Hyperbaric Facilities20 : Freestanding Birthing Center

A “decision tree” has been added to each of chapters12-17 (see X-3.4) to help determine what level ofsystem applies.

4-5.5.4 Gas System Information and Warning Signs

4-5.5.5 4-3.5.5 is incorporated by reference.

4-5.5.6 Vacuum Systems Policies

4-5.5.7 Vacuum Systems Recordkeeping

4-5.5.8 Vacuum Systems Information and WarningSigns

4-5.5.9 WAGD Policies

4-6 Level 4 Piped Systems

4-6.1 Piped Gas Systems - Level 4

4-6.2 Piped Vacuum - Level 4

4-6.3 Piped WAGD - Level 4

4-6.4 Performance Criteria and Testing - Level 4

4-6.5 Administration - Level 4

Chapters 12-20 Occupancy Specific Requirements

Occupancies : Chapters 12 - 19

In the 1996 edition, Chapters 12 - 17 cover :12 : Hospitals13 : Ambulatory Health Care Centers14 : Clinic15 : Medical Dental Office16 : Nursing Home17 : Limited Care Facilities18 : Home Care19 : Hyperbaric Facilities

Cross Reference

Page 22: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

Changes NFPA 99 1996 to 1999, Chapter 4 22

C-4-3.4 Recommended Vacuum Source SizingThis sizing methodology, which has been part of theappendix since the incorporation of the NFPA 56K,was missing a critical piece in the 1996 edition. Partof the material was in Appendix A and part was inAppendix C. The lost piece has been restored, andthe entire methodology has been relocated to Appen-dix C.

B-1.2.6 The CGA E-10 “Maintenance of Medical Gasand Vacuum Systems in Healthcare Facilities” is anadded reference. This document is obtained from theCompressed Gas Association.

Cross Reference

A-4-3.2.1 Recommended Vacuum Source Sizing

Page 23: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

23 Changes NFPA 99 1996 to 1999, Chapter 4

Links

Page 24: NFPA 99 Health Care Facilities - BeaconMedaes 96-99rev2.pdf ·  · 2011-05-24NFPA 99 Health Care Facilities ... 7 Changes NFPA 99 1996 to 1999, Chapter 4 About Levels A Discussion

Beacon Medical Products13325A Carowinds Blv’d, • Charlotte, NC 28241 • Phone 704 588-0854 • Fax 704 588-4949 • www.beaconmedical.com