NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are...
Transcript of NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are...
![Page 1: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/1.jpg)
© 2015 Illumina, Inc. All rights reserved.
Illumina, 24sure, BaseSpace, BeadArray, BlueFish, BlueFuse, BlueGnome, cBot, CSPro, CytoChip, DesignStudio, Epicentre, ForenSeq, Genetic Energy, GenomeStudio, GoldenGate, HiScan, HiSeq,
HiSeq X, Infinium, iScan, iSelect, MiSeq, MiSeqDx, MiSeq FGx, NeoPrep, NextBio, Nextera, NextSeq, Powered by Illumina, SureMDA, TruGenome, TruSeq, TruSight, Understand Your Genome, UYG,
VeraCode, verifi, VeriSeq, the pumpkin orange color, and the streaming bases design are trademarks of Illumina, Inc. and/or i ts affiliate(s) in the US and/or other countries. All other names, logos, and
other trademarks are the property of their respective owners.
NextSeq Sequencing
Run Monitoring
![Page 2: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/2.jpg)
2
By the end of this training, you will be able to:
– List the three options to monitor a run
– Describe the functionality of SAV
Session Objectives
![Page 3: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/3.jpg)
3
NextSeq Run Monitoring
Sequencing Screen in NCS
Monitor:
-On-instrument analysis
-Intensities Quality Scores
Sequencing Analysis Viewer
(SAV) in BaseSpace
Monitor run in greater detail
Sequencing Analysis Viewer
(SAV)
Monitor run in greater detail
![Page 4: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/4.jpg)
4
Viewing Run Metrics using
NextSeq Control Software
![Page 5: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/5.jpg)
5
NCS during On-Board Cluster Generation
![Page 6: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/6.jpg)
6
Note: Population of run metrics may be delayed by a couple of cycles due
to processing events
Run progress:• Status bar lists completed
cycles.
• Includes steps for
clustering, Read 1, Index 1
Read, Index 2 Read, Read
2, and the post-run wash
directly following the run.
A
B Q-Score:• Cycle 25
C Intensity: • Cycle 25
D Cluster Density (K/mm²):• Cycle 25
E Clusters Passing Filter:• Cycle 25
F Estimated Yield (Mb):• Cycle 25
G Flow Cell:• Shows which lane pair is
being imaged and on which
lane pair chemistry is being
performed.
Viewing Run Metrics on the Sequencing Screen
![Page 7: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/7.jpg)
7
Viewing Run Metrics using Sequencing
Analysis Viewer
![Page 8: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/8.jpg)
8
Sequencing Analysis Viewer
Files used by SAV
runinfo.xml
runparameters.xml
Interop files
Thumbnail files (optional)
Data Availability
Intensities after Cycle 25
Phasing/Prephasing after Cycle 25
Clusters Passing Filter (PF) after Cycle 25
Quality scoring after Cycle 25
PhiX alignment and error rates after Cycle 26
![Page 9: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/9.jpg)
9
SAV: Tabs
Run Metrics can also be reviewed offline from
any computer with access to the run folder
![Page 10: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/10.jpg)
10
SAV: Drop-down Options
Drop-down Options
![Page 11: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/11.jpg)
11 COMPANY CONFIDENTIAL – INTERNAL USE ONLY
SAV: Summary
![Page 12: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/12.jpg)
12
SAV: Imaging Tab
![Page 13: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/13.jpg)
13 COMPANY CONFIDENTIAL – INTERNAL USE ONLY
SAV: Indexing Tab
The Indexing tab is only available if the run is an index run
Note: For NextSeq data, indexing can be viewed in BaseSpace
after run completion or in SAV only after bcl2fastq2 conversion
![Page 14: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/14.jpg)
14 COMPANY CONFIDENTIAL – INTERNAL USE ONLY
Viewing Run Metrics using Sequencing
Analysis Viewer in BaseSpace
![Page 15: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/15.jpg)
15
BaseSpace: Charts
![Page 16: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/16.jpg)
16
BaseSpace: Run Summary
![Page 17: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/17.jpg)
17
Summary of Run Monitoring
• Intensity, cluster density and Q scores are available during the run
Sequencing run metrics can be viewed on NCS during a run
• During a run and after a run has completed
• Provide more metric options than NCS
Sequencing run metrics can be viewed remotely using SAV at anytime
• Cycles 25 through run completion: Intensity, Cluster Density, % PF, Yield, Q scores
Run metrics are populated after cycle 25 in SAV during a run
• Trending of run metrics is highly recommended to identify outliers
Absolute or relative values for run metrics will be dependent on the type of library
![Page 18: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/18.jpg)
18
Online Training
• Sequencing Analysis Viewer (SAV)
• NextSeq 500: Does My Run Look Good?
Documentation
• Sequencing Analysis Viewer User Guide
NextSeq 500 Run Monitoring Resources
![Page 19: NextSeq Sequencing Run Monitoring · 2017-09-21 · •Intensity, cluster density and Q scores are available during the run Sequencing run metrics can be viewed on NCS during a run](https://reader033.fdocuments.in/reader033/viewer/2022050412/5f895b1feceb666ae5157f72/html5/thumbnails/19.jpg)
19
Questions?