New Portable Hipot/ Megohmmeter Eliminate downtime and prevent … · 2014. 12. 23. · megohms @...
Transcript of New Portable Hipot/ Megohmmeter Eliminate downtime and prevent … · 2014. 12. 23. · megohms @...
-
285
ElectricalBrought to you by Cole-Parmer
Davis Instruments Phone: 800-358-5525 Fax: 800-433-9971 E-mail: [email protected]
Hipot Testers
Portable Hipot/Megohmmeter
Eliminate downtime and prevent electric hazards
PM6 / PAD56 features – Zero start voltage interlock
– Leakage current measurements from 0.1 to 5000 microamps DC (and from 1.0 to 5.0 mA AC, model PAD56 only)
– Adjustable overcurrent trip point
– Large, easy-to-read analog meters
– Rotary switch selection simplifies operation
PM15-2 Additional features – Illuminated pushbutton guard mode bypasses stray or unwanted leakage current
Model number PM6 PAD56 PM15-2Catalog number AB-20023-39 AB-20023-40 AB-20023-55
Input power 120 VAC or 220 VAC, 50/60 Hz (specify), 3 A, 1 phase120 VAC or 220 VAC, 50/60 Hz (specify),
3 A, 1 phase120 VAC or 220 VAC, 50/60 Hz (specify),
3 A, 1 phase
Output power Continuously adjustable from 0 to 6 kV DC @ 5 mAContinuously adjustable from
0 to 5 kV AC or 0 to 6 kV DC @ 5 mAContinuously adjustable from
0 to 15 kV DC @ 2 mAVoltmeter 31⁄2" analog, 0 to 3/6 kV 31⁄2" analog, 0 to 3/6 kV 31⁄2" analog, 0 to 7.5/15 kV DC
Combination current meter/megohmmeter (31⁄2" analog)
0 to 0.5/5/50/500/5000 microamps DC; 0.5 to 50/500/5000/50,000/500,000
megohms @ 2.5 kV DC; 1 to 100/1000/10,000/100,000/1,000,000 megohms
@ 5 kV DC
0 to 0.5/5/50/500/5000 microamps DC; 0 to 5 milliamps AC;
0.5 to 50/500/5000/50,000/500,000 megohms @ 2.5 kV DC;
1 to 100/1000/10,000/100,000/1,000,000 megohms @ 5 kV DC
0 to 0.5/5/50/500/5000 microamps DC; 2.5 to 100/1000/10,000/100,000/1,000,000
megohms @ 7.5 kV DC; 5 to 200/2000/20,000/200,000/2,000,000 megohms
@ 10 kV DC; 7.5 to 300/3000/30,000/300,000/3,000,000
megohms @ 15 kV DC
Metering accuracy ±2% of full scale ±2% of full scale ±2% of full scaleInput cable 7-ft (2-m), 3-prong with ground lug 7-ft (2-m), 3-prong with ground lug 7-ft (2-m), 3-prong with ground lug
Output cables 3 cables, each 10-ft (3-m) long for voltage, return and ground3 cables, each 10-ft (3-m) long for voltage,
return and ground3 cables, each 10-ft (3-m) long for voltage,
return and groundDimensions (W x H x D) 18" x 111⁄2" x 11" (457 x 292 x 279 mm) 18" x 111⁄2" x 11" (457 x 292 x 279 mm) 18" x 12" x 11" (457 x 305 x 279 mm)Price $ $ $
Wait! Don’t Forget…High voltage testing equipment, see pages 290–292.
Accessories
AB-17101-28 NIST-traceable calibration with data . . . . . . . . . . . . . . . . . . . . $
Wait! Browse 30,000+ products plus find Technical Resources to help you choose
There’s More atDavis.com
www.davis.com/Product/AB-20023-39?referred_ID=%2221349%22www.davis.com/Product/AB-20023-40?referred_ID=%2221349%22www.davis.com/Product/AB-20023-55?referred_ID=%2221349%22www.davis.com/Product/AB-17101-28?referred_ID=%2221349%22www.davis.com/?referred_ID=%2221349%22