New PCR Sample Formatdonar.messe.de/exhibitor/labvolution/2017/Q114941/pcr-chip-catalo… · Sample...
Transcript of New PCR Sample Formatdonar.messe.de/exhibitor/labvolution/2017/Q114941/pcr-chip-catalo… · Sample...
New PCR concept was born when precision molding technologymet film bonding know-how.Rapi:chip™ was developed from the understanding of challenges in routine PCR tasks. PCR duration could be dramatically reduced when efficient heat transfer is made during thermal cycling process. By designing unique 3-dimensional polymer chip of which bottom surface is made of thin film and precisely bonded with polymer body, ultra-fast thermal cycling became possible. As a certified manufacturer, Genesystem is manufacturing all Rapi:chip™ line of products in accordance with GMP standard.
Options are available for both thermal cycling and real-time PCR analysis. Rapi:chip™ is supplied in two formats. Standard version of chip has 10 wells and top of each well is open for real-time fluorescence measurement. Rapi:chip/16™ is new version of product which can accommodate 16 samples in it and is ideal for amplification of more number of samples at a time. This version of product has no capability for analysis of fluorescence signal.
Design isoptimized for reducing
the time for gene amplification.
Sample is loadedin flat and wide
chamber so that heat is efficiently delivered
to the sample.
Well volume is10μl only, which
helps fast heatingand cooling.
Contaminationfree and
transformation free
Options areavailable for thermal cycling and real-time
analysis.
Bottom surface ofchip is made of
thin film for efficient heat transfer.
Rapi:chip™PCR Chip forGENECHECKER™Enjoy Bene�ts ofNew PCR Sample Format
HOW TO LOAD SAMPLES
ORDERING INFORMATION
Size (W x D x H)WeightNumber of WellsVolume of Each WellAperture DiameterChannel HeightChannel HeightChannel HeightMaterial
38mm x 25mm x 6mm3.56 g10 wells for Model UF-150 and 16 wells for Model UF-10010µlΦ 0.6 mm0.5 mm8 mm2 mmTransparent Polymer (Transparency : 95% +)
SPECIFICATION ❶ ❺
WingsThese parts are used for easy handling with fingers or tweezers.
❷
Printed Well NumbersWell number is printed on the upper surface of chip for easy identification.
❸ ❹
Apertures Pipette tip fits in these apertures sothat sample and reagent could be loaded or collected easily.
Prepare sample according to
suggested protocol. Volume of sample mixture should be
10µl.
STEP 1. STEP 2. STEP 3. STEP 4.
002001002002002003002004002005002006
Rapi:chip™ PCR Chip for Model UF-150 GENECHECKER™ - Small Pack / 48/PKRapi:chip™ PCR Chip for Model UF-150 GENECHECKER™ - Medium Pack / 384/PKRapi:chip™ PCR Chip for Model UF-150 GENECHECKER™ - Large Pack / 768/PKRapi:chip/16™ PCR Chip for Model UF-100 GENECHECKER™ - Small Pack / 48/PKRapi:chip/16™ PCR Chip for Model UF-100 GENECHECKER™- Medium Pack / 384/PKRapi:chip/16™ PCR Chip for Model UF-100 GENECHECKER™ - Large Pack / 768/PK
Cat. No. Description / Pack Size
1
2
3
4
5
Seal entire holes using enclosed
sealing tape. Scrub the surface of sealed
area to secure sealing.
Place pipette tip into the inlet hole
of Rapi:chip™ and dispense
whole volume of aspirated sample.
Usingmicropipette,
aspirate prepared sample mixture
(10µl).
Genesystem Co., Ltd.310, Daejeon Bioventure Town, 1662, Yuseong-daero, Yuseong-gu, Daejeon, 34054, Koreaphone : +82 42 863 8551 fax : +82 42 863 8553 email : [email protected] web : www.genesystem.co.kr