New LED 250W OMNI-COB TM - HID Light Bulbs · 2019. 3. 14. · High Performance LED Omni-Cob Lamp,...

2
The HyLite High Power LED Omni-Cob Lamp is an energy-efficient replacement for use in a wide variety of new or retrofit applications. It features excellent optics for increased Visibility and Security, with a 360° beam to evenly illuminate the area. With its Universal Burning Position design and its compact size, the HyLite LED Omni-Cob Lamp is an excellent alternative to standard CFL, MV, HID, or HPS lighting and is ideal for Shoe Box, Area, Street and Roadway, Security, and Post-Top Lighting applications. With a lamp life of up to 60K hours, the HyLite LED Omni-Cob Lamps significantly reduce Relamping costs, thus decreasing Maintenance and Disposal costs. • Extremely Efficient: High Lumen Efficacy: 140 LpW • Fully Encapsulated: Shatter-proof, High-Shock & High-Vibration Resistant • Omni-Directional with Optimized Lighting Beam provides Maximum 360° Luminance with High Lumen Efficacy: 140 LpW • Bright white light for greater Visibility and Safety. High >80 CRI • Easy Installation: No Ballast necessary. Direct Retrofit into existing socket • Instant Start and Restart: No warm-up time required • Heat & Impact Resistant, UV Protected, Non-yellowing, Optical Grade Lens • Good Heat Dissipation with proprietary-designed Heat Sink • Cool Operation: Does not add to Heat Load while producing brilliant light • Safe and Reliable: Isolated Circuit Design. Integral 1 kV Surge Suppressor & Protection. Includes a Free 20kA in-line Surge Protection Device for added Protection • No Electro-Magnetic (EMi) or Radio Frequency Interference (RFi) • Ingress Protection: IP65. Complete protection against Contact, Dust Infiltration, and Splashed Water • Safe: Contain No Hazardous Materials; RoHS Compliant: No Lead, Mercury, Toxic Metals or Arsenic Gases. No Disposal requirements. Facilitates LEED ® points. • Environmentally Friendly: 98% of the HyLite LED Lamp is Recyclable Page: 1 of 2 Universal Burning Positioning Incandescent HPS/HID CFL HyLite 450W 250W 175W 54W 88% 78% 69% Energy Savings (%)* * Does not include Ballast Loss, Maintenance and Replacement Lamp Savings and Disposal Costs which can amount to additional Savings of 30~50%! Replace with 54W HL-OC-54W-E39 3.7" (93mm) 3.7" (93mm) High Performance LED Omni-Cob Lamp, 54W HyLite High Performance LED Omni-Cob Lamps - Up to 60,000 hour* Rated Design Life. Outstanding Quality of Light with Energy Savings of 88% over Incandescent, 78% over HPS / MH Lamps and 69% over CFL. OMNI-COB TM LED *Depending upon the ambient temperature of the installation location 250W MH / HPS Equivalent FREE! 20 kA In-line Surge Protection Device Included. Additional Protection for your HyLite Omni-Cob Lamp at no Cost! Lamp can be oriented in any position - does not affect or diminish the life of the Lamp Base Down Base Sideways Base Up NO LEAD, MERCURY, HEAVY METALS OR TOXIC GASES 98% RECYCLABLE LED Product Partner Reliable and Long-Lasting Warranty 5 years Vibration and Shock Resistant Solid State Radiation-Free No Humming IR UV No IR/UV No Noise 140 LpW LM-79 Tested High Efficacy LM-80 Tested ISTMT Tested Reliability Reduction of up to 88% Energy Costs Up to 60,000 Hours Low Voltage Longer Life & For Enclosed Luminaires Suitable 360° Illumination Zero Interference No EMi / RFi 4.3” (109mm) 10.7” (272mm) Ø 3.7” (93mm) E39/E40 6.4” (163mm) 1.6” (40mm) 54W HL-OC-54W-E39 100-277V, AC Suitable for Damp Locations Enclosed Fixtures

Transcript of New LED 250W OMNI-COB TM - HID Light Bulbs · 2019. 3. 14. · High Performance LED Omni-Cob Lamp,...

Page 1: New LED 250W OMNI-COB TM - HID Light Bulbs · 2019. 3. 14. · High Performance LED Omni-Cob Lamp, 54W HyLite High Performance LED Omni-Cob Lamps - Up to 60,000 hour* Rated Design

The HyLite High Power LED Omni-Cob Lamp is an energy-efficient replacement for use in a wide variety of new or retrofit applications. It features excellent optics for increased Visibility and Security, with a 360° beam to evenly illuminate the area.

With its Universal Burning Position design and its compact size, the HyLite LED Omni-Cob Lamp is an excellent alternative to standard CFL, MV, HID, or HPS lighting and is ideal for Shoe Box, Area, Street and Roadway, Security, and Post-Top Lighting applications. With a lamp life of up to 60K hours, the HyLite LED Omni-Cob Lamps significantly reduce Relamping costs, thus decreasing Maintenance and Disposal costs.

• ExtremelyEfficient:HighLumenEfficacy:140LpW

• FullyEncapsulated:Shatter-proof,High-Shock&High-VibrationResistant

• Omni-DirectionalwithOptimizedLightingBeamprovidesMaximum 360°LuminancewithHighLumenEfficacy:140LpW

•BrightwhitelightforgreaterVisibilityandSafety.High>80CRI

• EasyInstallation:NoBallastnecessary.DirectRetrofitintoexistingsocket

•InstantStartandRestart:Nowarm-uptimerequired

• Heat&ImpactResistant,UVProtected,Non-yellowing,OpticalGradeLens

• GoodHeatDissipationwithproprietary-designedHeatSink

• CoolOperation:DoesnotaddtoHeatLoadwhileproducingbrilliantlight

• SafeandReliable:IsolatedCircuitDesign.Integral1kVSurgeSuppressor &Protection.IncludesaFree20kAin-lineSurgeProtectionDevicefor added Protection

•NoElectro-Magnetic(EMi)orRadioFrequencyInterference(RFi)

• IngressProtection:IP65.CompleteprotectionagainstContact,Dust Infiltration, and Splashed Water

•Safe:ContainNoHazardousMaterials;RoHSCompliant:NoLead, Mercury,ToxicMetalsorArsenicGases.NoDisposalrequirements. Facilitates LEED® points.

•EnvironmentallyFriendly:98%oftheHyLiteLEDLampisRecyclable

Page:1of2

Universal Burning Positioning

Incandescent HPS/HID CFL HyLite

450W 250W 175W 54W

88% 78% 69% Energy Savings (%)*

* Does not include Ballast Loss, Maintenance and Replacement Lamp Savings and Disposal Costs which can amount to additional Savings of 30~50%!

Replacewith

54WHL-OC-54W-E39

3.7" (93mm)

3.7"

(93m

m)

HighPerformanceLEDOmni-CobLamp,54W

HyLite High Performance LED Omni-Cob Lamps - Up to 60,000 hour* Rated Design Life. Outstanding Quality of Light with Energy Savings of 88%overIncandescent,78%overHPS/MHLampsand69%overCFL.OMNI-COB TM

LED

*Depending upon the ambient temperature of the installation location

250WMH / HPSEquivalent

FREE!20 kA

In-line Surge Protection Device Included.

Additional Protection for your HyLite

Omni-Cob Lampat no Cost!

Lamp can be oriented in any position - does not affect or diminish the life of the Lamp

Base Down

Base Sideways

BaseUp

NOLEAD, MERCURY, HEAVY METALS

OR TOXIC GASES

98%RECYCLABLE

LED Product Partner

Reliable andLong-Lasting

Warranty

5years

Vibration andShock Resistant

Solid State

Radiation-FreeNo Humming

IRUV

No IR/UV

No Noise

140 LpWLM-79 Tested

High Efficacy

LM-80 TestedISTMT Tested

Reliability

Reduction ofup to 88%

Energy Costs

Up to 60,000 Hours

Low Voltage

Longer Life&

For Enclosed Luminaires

Suitable

360°

IlluminationZero

Interference

No EMi / RFi

4.3”

(109m

m)

10.7

”(2

72m

m)

Ø 3.7” (93mm)

E39/

E40

6.4”

(163m

m)

1.6” (

40m

m)

54WHL-OC-54W-E39

100-277V, AC

Suitable for

Damp Locations Enclosed Fixtures

Page 2: New LED 250W OMNI-COB TM - HID Light Bulbs · 2019. 3. 14. · High Performance LED Omni-Cob Lamp, 54W HyLite High Performance LED Omni-Cob Lamps - Up to 60,000 hour* Rated Design

Page:2of2

Model Delivered Maximum InputLine Base Dimensions&Weight(each) No. Watts Lumens InstallHeight Current Type Diameter Height Weight

HL-OC-54W-E39 54 7560 <26ft.(8m) 195~540mA E39/E40(Mogul) 3.7”(93mm) 10.7”(272mm) 2.2lb.(1kg)

OMNI-COB TM

LEDAs part of the company’s continuous product improvement program, HyLite reserves the right to change materials or modify the design of its product without notification. All Specifications subject to change without notice. All values are design and/or typical values when measured under laboratory conditions. Actual Values depend upon the ambient temperature of the installation location. Please consult factory for your specific requirements.

• MinimumLampCompartmentDimensionsforEnclosedFixtures:9.25”x9.25”x17.5”(235mmx235mmx440mm)

• ToPreventearlyLampFailure,LampshouldonlybeinstalledinOperatingEnvironmentsrangingfromaMinimumof-40°C(-40°F)toaMaximumof+55°C(131°F)

• Efficacy:140LpW • CRI:>80 • BeamAngle:360º • Max.THD(%):<15% • UniversalInputVoltage

• PowerFactor:>0.9 • Protection:IP65 • RatedLife:50~60,000Hrs. • Warranty:5Years 100~277V,AC50/60Hz.

• 347V,480VAvailable with with External Step-Down Transformer only. Please see HL-DT-70VA-480-240VSpec.Sheetat:https://hyliteledlighting.com/resources/specification-sheets/

• CCT:5000°K~5500°Kforgreatervisibility.Productswith2400°K-6500°K(CCT)areavailableas“SpecialOrders” only and with Longer Lead Times

High Performance LED Omni-Cob Lamp, 54W

Photometrics

Intensity: (Unit, cd) C0/180C90/270

135° 150° 165° 180° 165° 150° 135°

45° 30° 15° 0° 15° 30° 45°

60°

120°

105°

90°

75°

60°

120°

105°

90°

75°

100806040

0° 90° 135°90°135°180° 45°45°

80

20

40

100

60

180°

η = 100%

Ideal for high-quality illumination in:

• AreaLighting • ParkingLot • DecorativeLighting

• FloodLighting • AccentLighting • Roadway Lighting

• PendantLights • Driveway&WalkwayLighting • HighBayLighting

• TaskLighting • Historic/VintageFixtures • Stairwells,CorridorsLighting

• JellyJarLights • IndustrialBeacons • PedestrianTunnels

• GlobeFixtures • Explosion-proofFixtures • RailRoadStationPlatforms

• WallPacks • Freezer&ColdStorageLights • Site Lighting

• WallScones • DownLights • Security Lighting

©2012-2019HyLiteLED,LLC.,USA Formoreinformation,pleasevisit:https://hyliteledlighting.com/ 031219

Installation: HyLite LED Lampsaredesignedtoworkoff100Vto277V,AC.Ballast(ifequipped)mustbebypassedor removed from the fixture before installing the lamp. Eliminating the Ballast saves additional costs related to Maintenance, Energy Consumption and Performance. By-passingBallastwillalsoensurethatthereisnoEMi/RFinterference. The installer MUST ensure and verify that NO Part of the installed LED Lamp should touch the Fixture Housing or Components.

Failure to follow these Instructions will result in a Damaged Product and will VOID Warranty. It could also result in an ElectricShock,orFire.

Warning - Risk of Fire or Electric Shock

• Disable all Power to the Lamp before Inspection, Installation, or Removal. Failure to do so will createaHazardousandFatalWorkingEnvironment.

• SuitableforuseinDry,DampandWetLocations.LampmustbeinstalledinaccordancewithNational,State,and/orLocalElectricalCodes. DoNotOpen–NoUserServiceablePartsInside.

• OperateinFixturesthatprovidetheFreeFlowofAiraroundtheLampHeatSink.InEnclosedFixtures,ensuretheLamphasenoughSpaceforHeatDissipation. ThiswillensureLumenMaintenanceandextenditsWorkingLife.WhenproductsareusedinOutdoorFixtures,ensurethespaceisWaterproofandWellVentilated.

• NotforuseonaDimmerorRemoteControls.ThisLamp must be controlled only by either a Switch or an Electronic Photosensor. Do not use a Mechanical Sensor.

• NotintendedforusewithEmergencyExitFixturesorEmergencyExitLights.

• Caution:WhenInstallingLampsinCorrosiveEnvironments,HyLitesuggeststhataHigh-Temperature,Moisture-Resistant,SiliconeGreaseorSealantbeusedto protecttheMetal-threadedbaseoftheLEDLamptopreventWaterand/orMoistureIncursionthatcanleadtoPrematureDegradationoftheLampBaseand eventual Lamp Failure. This is especially recommended for LED Lamp installations near Saltwater bodies.

• InstallingSurge/LightningProtectorsisHighlyRecommendedandhelpstoEliminatePrematureDriverFailurecausedbySurgesandPowerFluctuations.