New Construction – Prime Tampa Retail...
Transcript of New Construction – Prime Tampa Retail...
Property Highlights:
• Join Dunkin Donuts in 8,750 SF multi tenant retail building
• End cap restaurant opportunity with outdoor seating
• O� ers Convenient access to I-4, I-275, and US Hwy 301
• Tra� c Count: Hillsborough Ave – 44,000 ADT
Property Description:8,750 SF multi tenant retail building located at the signalized intersection of Hillsborough Ave & Orient Rd. This opportunity o� ers great exposure and visibility to over 44,000 vehicle per day. This property is adjacent to the Hard Rock Hotel and Casino and is in close proximity to the Florida State Fair Grounds and Mid-Florida Credit Union Amphitheatre.
FOR LEASE
1 Mile 3 Mile 5 Mile
Total Population 3,622 61,028 191,226
Avg HH Incomes $48,377 $46,344 $49,302
Daytime population 6,941 44,469 133,044
Sheila Suhar D 813 498 1313M 727 254 [email protected]
Justin BoudreauD 813 413 6704 M 727 656 [email protected]
119 North 11th Street, Suite 300BTampa, FL 33602O 813 413 6700 hybridgecre.com
New Construction – Prime Tampa Retail Opportunity NWC of Hillsborough Ave. & Orient Rd., Tampa, FL
SURROUNDING RETAIL
New Construction – Prime Tampa Retail Opportunity NWC of Hillsborough Ave. & Orient Rd., Tampa, FL
Sheila Suhar D 813 498 1313M 727 254 [email protected]
119 North 11th Street, Suite 300BTampa, FL 33602O 813 413 6700 hybridgecre.com
Justin BoudreauD 813 413 6704 M 727 656 [email protected]
SITE
SITE
SITE PLAN
New Construction – Prime Tampa Retail Opportunity NWC of Hillsborough Ave. & Orient Rd., Tampa, FL
Sheila Suhar D 813 498 1313M 727 254 [email protected]
119 North 11th Street, Suite 300BTampa, FL 33602O 813 413 6700 hybridgecre.com
Justin BoudreauD 813 413 6704 M 727 656 [email protected]
8,750 SF Multi-Tenant Strip Center Option with Endcap/Inline Available
12' 12'
30'
24'
18'
5'
18'
24'
5'
PROPOSED2,400 SF
PROPOSED1,500 SF
3' LA
NDSC
APE
BUFF
ER
3' LANDSCAPE BUFFER
6' LANDSCAPE BUFFER
PROPOSED1,750 SF
PROPOSED1,500 SF
PROPOSED1,600 SF
8' LANDSCAPE BUFFER
PROPOSEDDUMPSTERLOCATION
12'
20'
10'
30'20'
75' 80'
20'
208.1'
256.3'
209.2'
PROPOSED MONUMENTSIGN
PROPOSED SEATINGAREA
STORM WATER MANAGEMENT AREA
STORM WATERMANAGEMENT
AREA
25' R25'
R
20' R
20' R
PROPOSEDRIGHT-IN/
RIGHT-OUTACCESS
PROPOSEDRIGHT-IN/
RIGHT-OUTACCESS
255.1
'
EXISTINGCONCRETE SIDEWALK
PROPOSEDCROSSACCESS
24'
18'
C
16' CC
CC
CC
CC
C
18'24'
9'8'
CONSTRUCTIONNOT APPROVED FOR
3820 NORTHDALE BLVD., SUITE 300BTAMPA, FLORIDA 33624
Phone: (813) 812-4100Fax: (813) 812-4101
FLORIDA BUSINESS CERT. OF AUTH. No. 30780
SU
ST
AIN
AB
LE
DE
SIG
NL
AN
DS
CA
PE
AR
CH
ITE
CT
UR
ES
ITE
CIV
IL A
ND
CO
NS
UL
TIN
G E
NG
INE
ER
ING
LA
ND
SU
RV
EY
ING
PR
OG
RA
M M
AN
AG
EM
EN
TP
ER
MIT
TIN
G S
ER
VIC
ES
TR
AN
SP
OR
TA
TIO
N S
ER
VIC
ES
NEW
EN
GLA
ND
UPS
TATE
NEW
YO
RK
NEW
YO
RK
MET
RO
LEH
IGH
VAL
LEY,
PA
SOU
THEA
STER
N, P
A
PHIL
ADEL
PHIA
, PA
SOU
THER
N M
ARYL
AND
BALT
IMO
RE,
MD
TAM
PA, F
L
CEN
TRAL
VIR
GIN
IAC
HAR
LOTT
E, N
CR
ALEI
GH
, NC
NO
RTH
ERN
VIR
GIN
IA
NEW
JER
SEY
TM
REH
OBO
TH B
EAC
H, D
E
BOC
A R
ATO
N, F
L
DISC
LAIM
ERTh
is dr
awing
and/o
r file
has b
een p
repa
red b
y Boh
ler E
ngine
ering
at th
e req
uest
of the
Pro
ject O
wner
or hi
s Rep
rese
ntativ
e and
is be
ing pr
ovide
d sole
ly as
a co
nven
ience
to th
e rec
ipien
t. Boh
ler E
ngine
ering
mak
es no
repr
esen
tation
rega
rding
the s
uitab
ility f
or th
e inte
nded
use b
y the
recip
ient. F
urthe
r, Bo
hler E
ngine
ering
mak
es no
repr
esen
tation
rega
rding
fitne
ss of
the e
lectro
nic fil
e for
any p
artic
ular p
urpo
se, o
r suit
abilit
y for
use w
ith an
y soft
ware
or ha
rdwa
re. It
is th
e rec
ipien
t's ob
ligati
on to
unde
rstan
d the
desig
n inte
nt an
d to u
se th
is dig
ital d
ata ap
prop
riatel
y.Du
e to t
he al
terab
le na
ture o
f elec
tronic
docu
ments
, Boh
ler E
ngine
ering
does
not m
ake a
ny ex
pres
sed o
r impli
ed w
arra
nty fo
r the
accu
racy
or co
mplet
enes
s of th
is inf
orma
tion.
The i
nform
ation
, des
ign an
d con
tent o
f this
file ar
e pro
priet
ary a
nd sh
all no
t be c
opied
or us
ed fo
r any
purp
ose w
ithou
t prio
r writt
en au
thoriz
ation
from
Boh
ler E
ngine
ering
.On
ly cu
rrent,
sign
ed an
d sea
led pl
ans s
hall b
e utili
zed f
or co
nstru
ction
purp
oses
.Vi
ewing
the c
onten
ts of
this f
ile sh
all se
rve as
your
ackn
owled
gmen
t of a
ccep
tance
of th
e abo
ve te
rms a
nd co
nditio
ns. B
y ope
ning t
his fil
e or t
hrou
gh th
e use
of th
e info
rmati
on co
ntaine
d her
ein, th
e rec
ipien
t agr
ees t
o ind
emnif
y and
hold
Bohle
r Eng
ineer
ing ha
rmles
s fro
m an
y los
s, da
mage
, liab
ility o
r cos
t, inc
luding
reas
onab
le att
orne
y's fe
es th
at Bo
hler E
ngine
ering
defen
ding s
uch c
laims
, aris
ing fr
om an
y use
or re
use o
f this
electr
onic
docu
ment
or in
forma
tion.
2008
Boh
ler E
ngine
ering
.
REVISIONS
REV DATE COMMENT BY
LOCATION OF SITE
FOR
PROJECT No.:DRAWN BY:CHECKED BY:DATE:SCALE:CAD I.D.:
SHEET NUMBER:
SHEET TITLE:
PROJECT:
H:\2016\FLT160145\DRAWINGS\CONCEPT\HILLS & ORIENT CONCEPT F 2017-02-28.DWG PRINTED BY: JARNOLD 3.01.17 @ 2:01 PM LAST SAVED BY: JARNOLD
JDABWK
02/01/2017AS NOTEDCONCEPT
CONCEPT PLAN
RADIANT
NWC HILLSBOROUGH AVE &ORIENT ROAD
TAMPA, FLHILLSBOROUGH COUNTY
CONCEPTPLAN 'F'
4
It's fast. It's free. It's the law.
www.callsunshine.com
VICINITY MAPN.T.S.
1"= 20'
0 2051020
SITE DATA TABLEJURISDICTION HILLSBOROUGH COUNTY
SITE AREA 1.22 ACRES
BUILDING AREA 8,750 SF
PROPOSED F.A.R. 16%
CURRENT ZONING CN
PROPOSED USE CN ZONING DISTRICT
FRONT SETBACK (ROW) 30'
FRONT/SIDE/REAR YARD BUFFER 8' (SOUTH), 3' (EAST) / 3' / 6'
MINIMUM OPEN SPACE 40%
PROPOSED OPEN SPACE 30% (0.37 ACRES / 1.22 ACRES)
PERCENT IMPERVIOUS 70% (0.85 ACRES / 1.22 ACRES)
PARKING PROVIDED (TOTAL)57 SPACES (INCLUDING 3 ADA SPACES, 10
COMPACT SPACES & 10 PERMEABLESPACES)
NOTES:1. THE CONCEPT REPRESENTED HEREIN IDENTIFIES A DESIGN CONCEPT RESULTING FROMLAYOUT PREFERENCES IDENTIFIED BY OWNER COUPLED WITH A PRELIMINARY REVIEW OFZONING AND LAND DEVELOPMENT REQUIREMENTS AND ISSUES. THE FEASIBILITY WITHRESPECT TO OBTAINING LOCAL, COUNTY, STATE, AND OTHER APPLICABLE APPROVALS ISNOT WARRANTED AND CAN ONLY BE ASSESSED AFTER FURTHER EXAMINATION ANDVERIFICATION OF SAME REQUIREMENTS AND PROCUREMENT OF JURISDICTIONALAPPROVALS.
2. THE CONCEPTUAL PLAN IS PREPARED FOR CONCEPTUAL PRESENTATION PURPOSESONLY AND IS NOT INTENDED FOR UTILIZATION AS A ZONING AND/OR CONSTRUCTIONDOCUMENT. THE EXISTING CONDITIONS SHOWN HEREON ARE BASED UPON INFORMATIONTHAT WAS SUPPLIED TO BOHLER ENGINEERING AT THE TIME OF PLAN PREPARATION ANDMAY BE SUBJECT TO CHANGE UPON AVAILABILITY OF ADDITIONAL INFORMATION.
SITE
STORMWATER MANAGEMENT NOTE:THE STORMWATER MANAGEMENT AREA SHOWN HEREIN IS CONCEPTUAL AND SHALL NOTBE USED FOR DESIGN, CONSTRUCTION OR COST ESTIMATES. THIS PLAN DOES NOT TAKEINTO CONSIDERATION THE CURRENT GEOTECHNICAL CONDITIONS OR JURISDICTIONALDRAINAGE DESIGN.
VARIANCES:· 6.06.02 - REDUCE 6' LANDSCAPE BUFFERS ON THE WEST BOUNDARY TO 3'.
· 6.06.04 - REDUCTION OF PERIMETER BUFFER ADJACENT TO RIGHT-OF-WAY FROM8' TO 3' ON EASTERN BOUNDARY.
· 6.01.01 - INCREASE IMPERVIOUS SURFACE AREA FROM 60% TO 70%.