DHP-308AV/DHP-309AV Powerline AV+ Mini Adapter Powerline AV+ Mini Starter Kit Sales Guide
New (and old) oceanographic tools 2012 Workshop DHP 2012 Tina Miller-Way.
-
Upload
christian-richards -
Category
Documents
-
view
213 -
download
0
Transcript of New (and old) oceanographic tools 2012 Workshop DHP 2012 Tina Miller-Way.
New (and old) oceanographic New (and old) oceanographic toolstools
2012 2012 WorkshopWorkshop
DHP 2012DHP 2012Tina Miller-WayTina Miller-Way
Properties of water of interest
• Parameters, units, significance– Temperature– Salinity– Dissolved oxygen – Turbidity– Light levels– Depth…
Tools to measure these properties - depth• Sounding lines
– Problems…
• Pressure sensor
• Sonar
QuickTime™ and a decompressor
are needed to see this picture.
Tools to measure these properties - temperature
• Thermometer - Hg-based
• how to do at depth? - reversing
QuickTime™ and a decompressor
are needed to see this picture.QuickTime™ and a
decompressorare needed to see this picture.
Tools to measure these properties - salinity
• Direct or indirect measurement
• Refractometer
• Conductivity sensor
Tools to measure these properties - turbidity
• Secchi disk
• transmissometer
QuickTime™ and a decompressor
are needed to see this picture.
Tools to measure these properties - dissolved oxygen
• Methods - chemical, electrical, optical
Optode
Polarigraphic electrode
Winkler
Dissolved oxygen
• Concentration vs saturation• Saturation -
– expected amount given temp, pressure, salinity (ideal gas law) = 100% saturation
– Under, over or at saturation– Units = %
• Concetration - units = mg/l (or ppm, mmol)
QuickTime™ and aGraphics decompressorare needed to see this picture.
6
7
8
9
10
11
12
13
14
0 5 10 15 20 25 30
Temperature (°C)
0 ‰
15 ‰
35‰
Dissolved oxygen nomographs
• Use nomographs to determine expected DO levels (100% saturation)
Dissolved oxygen nomographs
• use to determine saturation level
Example O2 data
Tools to measure these properties - light
• What wavelengths?– Photosynthetically active
radiation (PAR) sensor
• How to account for changes in incident light?– Deck sensor
Other parameters
• Chlorophyll levels - fluorometer
But these properties vary with depth
thermocline
Temperature (°C)
Dep
th (
km)
1
2
halocline
Salinity (‰)
Dep
th (
km)
1
2
Density (g/ml)
Dep
th (
km)
1
2
pycnocline
• Typical open ocean profiles• Called - a hydrocast
Monitoring units
• Hydrolab/YSI = brands
Combined units
• moored, deployed, mobile
• CTD
• Argo ’floats’
Hydroloab hydrocast
CTD hydrocast
See our CTD hydrocast
Other oceanographic tools
• Water samplers– Nansen / Niskin bottle– messengers