Network Master Pro/Flex Release...

47
Network Master Pro/Flex Release Notes 1 TAA-1ETNMX0054-47 2020-08-11 Anritsu Corporation Network Master Pro/Flex Release Notes Product Configuration The following table shows the relationship between the changed application and modules described in the Revision History. Main frame Module Changed Application MT1100A/MT1000A Common [Framework][Remote] MT1100A MU110010A MU110011A MU110012A MU100013A [ETH][OTN][CPRI][FC][SDH/SONET][SDHPDH][GPS][MxH] MT1000A MU100010A MU100090A MU100020A MU100021A MU100022A MU100023A [OTDR][FTTA][OLTS] MU100040A MU100040B [CPRI-RF]

Transcript of Network Master Pro/Flex Release...

Page 1: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

1 TAA-1ETNMX0054-47

2020-08-11 Anritsu Corporation

Network Master Pro/Flex Release Notes

Product Configuration

The following table shows the relationship between the changed application and modules described in the

Revision History.

Main frame Module Changed Application

MT1100A/MT1000A

Common

― [Framework][Remote]

MT1100A MU110010A

MU110011A

MU110012A

MU100013A

[ETH][OTN][CPRI][FC][SDH/SONET][SDHPDH][GPS][MxH]

MT1000A MU100010A

MU100090A

MU100020A

MU100021A

MU100022A

MU100023A

[OTDR][FTTA][OLTS]

MU100040A

MU100040B

[CPRI-RF]

Page 2: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

2 TAA-1ETNMX0054-47

Latest Installer File Name

MT1000A MT1100A

10.03.MT1000A_SW

10.03.MU100011A_DATA

MX100001A-Setup-10.03-xxxxx.exe

MX100003A-2.0.0.55-xxxxx.exe

10.03.MT1100A_SW

MX100001A-Setup-10.03-xxxxx.exe

MX100003A-2.0.0.55-xxxxx.exe

The following table shows the latest software and corresponding operation manuals.

Operation Manual Doc. No. MT1000A MT1100A

MT1000A Network Master Pro

MT1100A Network Master Flex

Remote Scripting Operation Manual

M-W3736AE 27th 27

th

MT1000A Network Master Pro Transport modules

Operation Manual

M-W3933AE

15th

MT1100A Network Master Flex Operation Manual M-W3735AE - 28th

MT1000A Network Master Pro OTDR Modules

Operation Manual

M-W3810AE

17th -

MT1000A Network Master Pro OTDR Modules

Remote Scripting Operation Manual

M-W3859AE 6th

MX100003A Scenario Edit Environment Kit Operation

Manual

M-W4042AE 1st 1

st

MT1000A MU100040A/MU100040B Network Master

Pro Operation Manual

10580-00443 A -

Page 3: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

3 TAA-1ETNMX0054-47

The Relation Between Software and Operation Manuals

MX100003A

Version

Related MX100003A

Operation Manual Edition

Working MT1000A/MT1100A

Firmware Version

2.00.55 1.0

Title Changed1

10.02 to 10.03

2.0.0.54 13.0 10.02 to 10.03

2.0.0.53 13.0 10.00 to 10.01

2.0.0.52 12.0 9.09 to 9.13

2.0.0.51 11.0 9.07 to 9.08

2.0.0.36/43/45/48/49/50 5.0 to 10.0 5.04 to 9.06

2.0.0.23 4.0 5.04 to 7.04

1.0.0.76 2.0 to 3.0 5.04 to 7.01

1.0.0.72 1.0 5.04

1 The title changed from “MX100003A MT1000A/MT1100A Scenario Edit Environment Kit Operation

Manual” to “MX100003A Scenario Edit Environment Kit Operation Manual”.

MT1000A/MT1100A

Firmware

Version

Related Operation Manual Edition

MT1000A MT1100A

MU10001xA

(Transport)

MU100040A/B

(CPRI-RF)

MU10002xA

(OTDR)

MU11001xA

(Transport)

10.03 15 A 17 28

10.02 14 A 16 27

10.01 13 A 15 26

10.00 13 A 15 26

9.13 13 A 14 26

9.12 12 A 13 26

9.11 11 A 12 25

9.10 10 A 11 25

9.09 9 A 11 24

9.08 8 A 10 23

9.07 8 A 10 22

9.06 7 A 10 21

9.05 6 A 10 20

9.04 5 A 10 19

9.03 5 A 10 19

9.02 5 A 9 19

Page 4: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

4 TAA-1ETNMX0054-47

9.01 5 A 9 19

9.00 4 A

Title Changed2

9 18

8.02 3 A 9 17

8.01 2 A 9 16

8.00 1

Title Changed3

A 8 -

7.05 15 A 7 15

7.04 14 A 6 13

7.03 14 A 6 13

7.02 13 A 5 12

7.01 12 A 5 10

7.00 12 A 5 10

6.02 11 - 4 10

6.01 11 - 4 10

6.00 11 - 4 10

5.04 10 - 3 9

5.03 10 - 3 9

5.02 10 - 3 9

5.01 10 - 3 9

5.00 9 - 2 8

4.00 8 - 1 7

3.04 8 - - 7

3.03 8 - - 7

3.02 7 - - 6

3.01 6 - - 5

3.00 5 - - 4

2.05 4 - - 4

2.04 4 - - 3

2.03 3 - - 2

2.02 2 - - 2

2.01 2 - - 2

2.00 2 - - 1

1.00 1 - - 1

2 The title changed from “MT1000A MU100040A Network Master Pro Operation Manual” to “MT1000A

MU100040A/MU100040B Network Master Pro Operation Manual”. 3 The title changed from “MT1000A MU100010A Network Master Pro Operation Manual” to “MT1000A

Transport Modules Operation Manual”.

Page 5: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

5 TAA-1ETNMX0054-47

Installation Procedure

1. When using battery, make sure that there is 40% (or more) power in the battery of the instrument.

2. Remove the USB memory from the MT1000A/MT1100A.

3. Press the power button to shut down the MT1000A/MT1100A. Never force to power off by holding the

power button pressed for several seconds.

4. Remove the AC adapter or cable and see the power button turns to gray.

5. Copy the installer (X.XX.MT1000_SW, X.XX.MU100011A_DATAor X.XX.MT1100_SW) to an empty

USB memory stick formatted to FAT32.

6. Insert the USB memory stick into MT1000A/MT1100A.

7. Boot MT1000A/MT1100A to start installer.

The instrument will detect the USB stick, and start installing the software. After the installation has

finished the instrument will reboot and start with the new software.

When installing MT1000A software which includes MU100011A, the installation of MU100011A data

starts automatically at the Network Master rebooting.

8. Remove USB stick after installation is complete

You can check the installed version at System Information screen.

Page 6: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

6 TAA-1ETNMX0054-47

Installation Procedure via network.

1. When using battery, make sure that there is 40% (or more) power in the battery of the instrument.

2. Install the Control Software(MX100001A) on your PC.

(Please refer “3.5.1 Installation of Control Software” on MT1000A Transport Modules Operation

Manual or MT1100A Network Master Flex Operation Manual.)

3. Configure the Ethernet communication between the Control Software(MX100001A) and

MT1000A/MT1100A. (Please refer “3.5.2 Connection and Setup” on MT1000A Transport Modules

Operation Manual or MT1100A Network Master Flex Operation Manual.)Select the update tab on

Control Software to show the upgrading box.

4. Touch Select File to launch the dialog box.

5. Select the software file. Progress bar shows Upload Progress. Touching Cancel aborts the file

uploading.

6. After file uploading finishes, touch Start Installation.

Touching Start Installation will reboot the Network Master. Installation process cannot be remotely

monitored. Please reconnect after several minutes.

Page 7: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

7 TAA-1ETNMX0054-47

SEEK Scenario

After installing the software, a set of SEEK scenario is copied in the “/Internal/windowsinstaller/ scenario”

folder. Register the scenario to use it. Refer to the “4.2.1 Registering the Scenario” in the Scenario Edit

Environment Kit Operation Manual.

Scenario Name Description Module

xCVRQuickCheck_03.obcfg This scenario quickly checks optical modules..

Refer to the

“Optical Transceiver Simple Check xCVR Quick Check

SEEK Scenario” on Anritsu WEB Site.

MT1000A

MU100010A

MU100011A

xCVRQuickCheck_00.obcfg MT1100A

MU110013A

Page 8: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

8 TAA-1ETNMX0054-47

Revision History

Version Date Description

10.03 2020-08-11 Key Added Features

[SEEK] Added support for MT1040A.

2020-07-13 Key Added Features

[ETH] Added following functions to RFC2544. (12697)

- Added Latency, Jitter, Throughput Pass/Fail threshold value

- Added Latency, Jitter, Throughput Pass/Fail threshold value

- Support for simultaneous Latency and Packet Jitter

measurement

[ETH] Improved Latency and Packet Jitter measurement

accuracy at RFC2544 and SAT (Y.1564) measurement. (13550)

[OTDR] Added Korean language GUI descriptions. (12847)

Fixed bugs

[MxH] Fixed bug causing incrementing PRBS sync alarm when

executing communications test while either IEEE1588 or SyncE

set to ON at eCPRI test. (12368)

[ETH] Fixed bug preventing multicast VLAN support for

IEEE1588v2 SMPTE profile. (13485, 13472)

[OTDR] Fixed bug causing slow measurement start after

switching wavelength when wavelength set to ALL at Separate

(Individual) measurement mode setting. (12894)

[OTDR] Fixed bug at transmission loss Pass/Fail evaluation

when Pass/Fail evaluation reference set to ISO/IEC or JIS.

(13537)

10.02 2020-06-04 Key Added Features

Added support for MX109020A Site Over Remote Access;

installing MT1000A-011 option enables remote control and file

access using MX109020A. (13368)

[VIP] Added support for selection of all G0382A option tips.

(13332)

[VIP] Added message display when pass/fail analysis results

range off screen edge. (13333)

Fixed bugs

[ETH] Fixed bug causing one lost Frame at RFC2544

measurement using two MT1000A units with MT1000A

operating as Reflector; bug occurs only with 100, 40, and

25GbE interfaces. (12833)

Page 9: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

9 TAA-1ETNMX0054-47

[ETH] Fixed bug causing crash when changing [Line load] unit

at 25GbE setting of RFC2544 application. (12939)

[ETH][MxH] Fixed bug causing incorrect detection of PRBS

sync alarm when connecting/disconnecting cable during BER

measurement using cross PRBS pattern at 25GbE or faster

interface. (12594)

[ETH] Fixed bug causing forced restart when outputting

Statistics as .csv file after measuring interval length with [No

Interval] set at Ethernet application. (12820)

[ETH] Fixed bug sometimes causing output of incorrect packet

when sending packets with Frame Size set to [Step] at 25GbE

or faster interface. (12864)

[VIP] Fixed bug preventing normal autofocus operation with

some tips. (13326)

10.01 2020-05-11 Fixed bugs

[ETH][MxH] Fixed bugs when receiving Ping packet of 2048

bytes or more at 25, 40, and 100GbE interfaces. (13380)

- [ETH][MxH] Sometimes no response to Ping request

- [Ping] Sometimes unable to measure at applicable

conditions

- [RFC2544] Sometimes unable to measure when performing

[Router Latency Test] at applicable conditions

10.00 2020-02-20 Key Added Features

[New HW] Added new MU100023A OTDR 1.31/1.55/1.65-um

SMF module to product line.

[OTDR] Added “Launch Length Correlation” and “Receive

Length Correlation” items to Patch Cord settings.

[OTDR] Added 200 ns Pulse Width to 0.5 km Distance Range.

[OTDR] Added function for batch creation of reports (pdf, xml, or

csv) using “.sor” file data saved in built-in or USB memory;

function enabled only at Standard OTDR and FTTA

applications.

[OTDR] Added function for outputting loss table results (pdf,

xml, or csv) at OLTS application.

[OTDR] Improved splitter detection accuracy at

auto-measurement.

[OTDR] Added SCPI command remote control function at OLTS

application.

Page 10: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

10 TAA-1ETNMX0054-47

[SEEK] Added support for outputting each application

measurement result as one report (pdf, xml, or csv) for

measurement sequence including several applications.

[SEEK] Added function for describing scenarios such as branch

conditions based on information loaded from data described in

text file. (12808)

[SEEK] Added OLTS application support for

MU100020A/21A/22A/23A OTDR modules.

Fixed bugs

[ETH] Fixed bug preventing display of SyncTest application start

screen depending on option combination when using

MU100010A software versions later than 9.10. This bug occurs

with the following hardware: (12687)

With MT1000A-005 installed

With MU100010A-011 installed

With MU100010A-001 not installed

[ETH][MxH] Fixed bug preventing FEC Symbol Error insertion

for SFP28 when MU100011A-023 not installed when using

MU100011A Ethernet application with eCPRI/RoE BERT.

(12701)

[OTDR] Fixed bug preventing splitter loss display at Pass/Fail

evaluation. (12736)

[OTDR] Fixed bug causing MT1000A freeze when performing

averaging measurement when Auto-measurement Mode set to

“Advanced” and OTDR Test Mode set to “Auto”. (12482)

9.13 2019-12-12 Key Added Features

[OTDR] Added Pass/Fail function for measured Loss results

based on either ISO/IEC or JIS standards. (12648)

Fixed bugs

[Framework] Updated to not include initialization time (time

required until OSC lamp lit) in elapsed time after MU100090A

built-in oscillator power-on displayed in GPS pop-up. Now

able to correctly confirm 3-hour warm-up time required to meet

Holdover specification. (12642)

[Framework] Fixed bug occasionally preventing recognition of

USB memory. (12537)

[OTDR] Improved issue causing generation of unnecessary

reflections at non-Event points (other than connectors and

Page 11: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

11 TAA-1ETNMX0054-47

splices) at OTDR waveform measurement. This issue occurs

with the old firmware version when setting a short distance

range for the measured fiber. (12488)

[ETH] Fixed bug preventing correct statistical results ‘Remote

Failure’ measurement. This bug occurs when setting Port Mode

to ‘Forced’. (12585)

[VIP] Fixed following G0382A bugs: (9850)

Non-detection of G0382A when G0382A connected to

Network Master.

Either operation panel freeze or occasional Network Master

reboot when disconnecting G0382A from Network Master.

9.12 2019-10-10 Key Added Features

[ETH] Added Link fault signaling (LFS) emulation function for

MU100011A module interfaces of 10GbE or faster (12438)

Fixed bugs

[ETH] Fixed following bugs related to DHCP functions

Bug displaying error message each time expired DHCP

lease renewed during measurement (12436)

Bug causing unwanted address release when using DHCP

server for authenticating validity of "server identifier" option

(12367)

Bug disabling DHCP settings after address released

(12447)

[ETH] Fixed bug enabling Remote Fault detection function for

interfaces other than 1GbE auto-negotiation (12519)

[ETH][OTN] Fixed bug enabling [+OTN] button for each

MonGen, Reflector, RFC2544, and SAT application when

MU100011A-001 or MU100011A-003 not installed in

MU100011A (12416)

[Framework] Fixed bug preventing login to WLAN networks

including backslash (¥) or double quotation mark (") in SSID.

Names after SSID registration are: (¥) becomes (¥¥), and (")

becomes (¥") (12433)

[FC] Fixed bug causing unwanted insertion of IDLE pattern

between NOS pattern at insertion of Not operational (NOS)

alarm (12440)

[FC] Fixed bug causing unwanted conversion of Alarm NOS

pattern to Remote Fault pattern at 16GFC interface (12440)

Page 12: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

12 TAA-1ETNMX0054-47

[FC] Fixed bug causing error in insertion pattern value at

R_RDY error insertion (12440)

[FC] Fixed bug preventing insertion of IDLE pattern between

EOF pattern and R_RDY pattern when inserting error burst

(12440)

[SEEK] Fixed bug causing Fail result without executing loop at

scenario with loop processing description (12469)

9.11 2019-09-05 Fixed bugs

[ETH][MxH] Fixed bug causing abnormally large Latency

measurement result when using MU100011A 10GbE or lower

interface Related applications are Ethernet BERT, MonGen,

RFC2544, SAT (Y.1564), and eCPRI/RoE BERT. In addition,

when the SAT (Y.1564) application Latency result is abnormal,

the measurement result is an unacceptable SAC violation.

(12454, 12472)

[ETH][MxH] Fixed bug in MT1000A Ethernet BERT, Ethernet

MonGen, and eCPRI/RoE BERT causing resolution of Latency

and Jitter measurement results to not meet product

specification (5 ns). (12470)

9.10 2019-06-18 Key Added Features

[ETH] Added function to IEEE1588v2 screen to display Clock

Class level delivered by network; in addition to Class level,

added display of QL value following existing ITU-T conversion

rule. (12257)

[ETH] Added G8275.2 to IEEE1588v2 profile. (12238)

[ETH] Added function for editing PTP message joint header

flagField and displaying decode results. Added screen for

changing master port flagField to IEEE1588v2 settings and

screen for displaying code result in the IEEE1588v2 monitor;

additionally, flagField value is correctly initiated following the

Clock Class setting. (11567, 12319)

[ETH] Increased SyncTest maximum measurement time to 3

days. Added function for auto-saving all measurement results to

CSV file for measurement times exceeding 12 hours that cannot

be saved to display memory. (12239)

[ETH] For Y.1564, increased decimal points from 0 to 4 places

for Availability threshold value and increased measurement

result decimal points from 0 to 5 places to support 5G network

Page 13: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

13 TAA-1ETNMX0054-47

measurements requiring 99.9999% availability. (12249)

[ETH] Added function in Statistics for switching units between

byte and bit display. (12105)

[ETH] Added function for outputting Statistics in CSV format to

simplify analysis of long-term measurement results with

external software, such as Excel. (11989)

[MxH] Added 12G (Opt-9) and 25G (Opt-10) to CPRI/OBSAI

BERT line rates. (12237)

[RemoteGUI] Added function for placing remote MT1000A into

standby mode using MX100001A software. (12235)

Fixed bugs

[ETH] At 25G and higher rates when Frame size of 63 bytes or

less selected, fixed bug causing displayed Tx Frame value to be

twice actual value. (12200)

[ETH] Fixed bug causing the display to freeze when displaying a

long-term graph measurement in SyncTest. (11176, 11314)

[ETH] Fixed bug causing inability for gateway to be correctly set

when using a DHCP server over IPv4 at v9.09 Ethernet

applications. (12248)

[ETH] Fixed bug causing inability to set correct maximum IFG

value for the Line Load setting (12175)

[ETH] Fixed bug causing ARP resolution to not work across

different VLANs. (12055)

[ETH] Fixed bug preventing the correct output of random

address ranges compared to the variable address settings field

in the stream settings. (10905, 11117)

[ETH] Changed behaviour when loading a saved file with a

source MAC address set to its own unit factory default, will now

configure the unit to the factory default source MAC address the

file is being loaded on. (11112)

[ETH] Fixed a bug, some settings (announce interval, sync

interval, and minimum delay request interval) did not properly

recover after loading file setup or result when using ITU-T

G.8275.1 or SMPTE 2059 profiles in the IEEE1588v2

settings.(12322)

[RemoteGUI] Added function for placing remote MT1000A into

standby mode using MX100001A software. (12235)

[ETH][MxH] SyncTest and Pass Through now start without the

Page 14: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

14 TAA-1ETNMX0054-47

requirement of selecting the two ports. (12236)

[ETH][MxH] Fixed bug causing inability to set FEC ON/OFF

when using SFP28, in Ethernet and eCPRI/RoE BERT

applications for v8.01 and later. (12258)

[Framework] Fixed bug causing inability to display option name

correctly in System Information for v9.09 MU100010A and

MU110010A. (12308)

[Framework] Fixed bug preventing file sharing with Windows10

version 1709 and later. (12186)

[OTDR] Fixed bug preventing update of subsequent power

meter measurement values when cancelling the execution of

power-meter zero offset. (12240)

9.09 2019-02-13 Key Added Features

"[ETH] Added following functions to each BER, MonGen, and

SyncTest application. (11970, 12182)

1. IGMP/MLD Join/Leave function

2. Support for SMTPE 2059 IEEE1588v2 profile"

[ETH] Added Burst Length/Gap input function in the Burst

settings of both MonGen and ChannelStat application (12094)

[ETH][MxH] Added IPv6 Gateway function for Ethernet and

MxH categories. (11238)

[MxH] Added option to eCPRI/RoE application to use 25G

eCPRI on two ports simultaneously. (11969)"

[Framework] Added function to measurement results statistical

display to automatically display k/M/G value matching

measurement value. (12066)

[Framework] Added progress bar during application startup.

(12065)

[OTDR] Added function for outputting OTDR measurement

results in JSON format. (12168)

Fixed bugs

[ETH] Fixed bug when a very low frequency of errored frames

occured, causing rounding of normal frame measurement result

to nearest whole number and non-display of decimal points

(99.9999% becomes 100.00%). (12056)

[ETH] Fixed bug preventing display of all measurement results

when Latency result is 1 ms or more. (12167)

[ETH] Fixed bug at SyncTest application causing green status

Page 15: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

15 TAA-1ETNMX0054-47

display even with no input signal to Ext10M, Ref1pps and

dut1pps. (11819, 9412,10860)

[ETH][OTN][SDH][CPRI][FC] Fixed bug causing save failure

when saving Event log in .csv format after measurement.

(11264)

[ETH][OTN][NoFrame] Fixed bug preventing writing of values to

page 2 and 3 of QSFP28 internal register when using J1756A

CFP2-QSFP28 Adapter with MU110012A/MU110013A. (11988)

[Remote][ETH] Fixed bug preventing capture of Rx Total good

bytes using SCPI command (IFETCH). (12115)

[Remote][ETH] Fixed bug causing save error when space

character present after file name when saving frame capture

using SCPI command. (12024)

[VIP] Fixed bug do not causing G0382A to become active when

using VIP application when G0382A entered automatic standby

status. (12173)

[ETH] Fixed bug in v9.07 and v9.08 when SFP28 configuration

file loaded, forcing IEEE1588v2 and SyncE to OFF and

preventing change to ON. (12054)

9.08 2018-11-21 Fixed bugs

[SEEK] Fixed bug causing inability to change frequency

variation setting from 0 ppm when measuring BER at

xCVRQuickCheck_02 scenario. (11995)

9.07 2018-09-19 Key Added Features

[ETH] Added function to RFC2544 application allowing multiple

setting of any frame size. (11829)

[ETH] Added ON/OFF function for [Remote Fault] display at

negotiation status of BERT/Mon/Gen application. (11861)

[MxH] Added function to CPRI/OBSAI BERT application for

generating/analyzing OBSAI frame. (11873)

[Framework] Added function to show who are using the port on

the resource monitor screen of MT1000A/MT1100A. (11886)

[Framework] Added Finnish to GUI languages. (10993)

Fixed bugs

[Framework] Fixed bug preventing backup of application

settings when MT1000A/MT1100A WLAN network connection

keeps fail for long time. (11313)

[ETH] Fixed bug in the IPv4 checksum header when sending

Page 16: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

16 TAA-1ETNMX0054-47

multiple streams including VLAN/IPv4 or MPLS/IPv4 using

Mon/Gen application. (11855)

[ETH] fixed bug displaying a Frame capture buffer size of 513

kB and larger which isn’t possible using v9.05/v9.06 25GbE

interface. (11950)

[MxH] Changed name of "CPRI/OBSAI P.Thru" application to

"CPRI P.Thru". (11976)

[Remote][OTDR] Fixed bug causing main unit to restart when

sending :OTDR:TRAC:LOAD:TEXT? command to capture

waveform data. (11951)

9.06 2018-07-19 Key Added Features

[ETH] Added function for synchronizing time of two MT1000A

units using 1PPS and 10MHz for Latency when MU100011A

installed. (11791)

[ETH] Improved PTP measurement results Accuracy and

Latency results Accuracy and Resolution. (10877, 11790)

[ETH] Added support for RFC6349 over IPv6. (10879)

[ETH] Added second (sec) units display to vertical axis in the

Latency/Jitter sections of the BERT and RFC2544 applications.

(10789, 10824)

[Framework] Increased maximum number of alphanumeric

characters from 32 to 64 for PSK (WPA and WPA2) WLAN

connection authentication. (11526)

[FC] Added Block Error detection and insertion functions for

10GFC and 16GFC in the BERT application. (11516)

Fixed bugs

[ETH] Fixed bug in BERT and Mon/Gen applications when

reading CFG file causing TCP protocol "Listen mode" setting to

always load as "Off". (11214)

[ETH] Fixed bug in BERT application from v9.00 when using

100G interface and inserting FEC symbol error causing

application to crash when selecting either "Burst/sec" or

"Burst/10 sec" as Insertion setting. (11344)

[ETH] Fixed bug in Mon/Gen application preventing the TCP

protocol from establishing TCP sessions on streams 9 to 16.

(11221)

[ETH] Fixed bug in Sync application preventing display of Port2

TE1 and Terr graph results even when loading saved

Page 17: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

17 TAA-1ETNMX0054-47

measurement-results file. (11655)

[Framework] Fixed bug in File Browser from v9.02 preventing

the file saved time from being displayed. (11042)

[Framework] Fixed bug when editing a WLAN network that has

already saved the PS Key value and is described as "[key is

configured]"", if you save this value the PSK value is

overwritten. (11267)

[OTN] Fixed bug in BERT application causing an error after

selecting; RTD measurement mode, quitting application,

restarting application, and changing measurement mode to

BERT. (11495)

[OTDR] Fixed bug in Multi-Pulse Measurement preventing

correct calculation of dB/km and Cum.Loss (dB) values. (11836)

[Eth] Fixed bug sometimes causing lower measured throughput

result than actual rate using RFC6349 Application. (10883)

9.05 2018-05-08 Key Added Features

[ETH] Added 25 GbE interface to SyncTest application. (10880)

[OTN] Added OTU2e-FC1200 mapping for MU100011A

module. (10803)

[MxH] Added eCPRI/RoE BERT application. (10878)

[Framework] Added Korean language to Transport functions.

(10837)

Fixed bugs

[ETH] Resolved issue returning an incorrect ARP Reply with

below IP and MAC configuration for MU100011A with v9.00 or

later software. (11069)

SrcMAC 00-00-00-00-00-00

SrcIP 0.0.0.0

[ETH] Resolved issue displaying incorrect latency measurement

when using 2 ports in RFC 2544, MonGen, BERT applications

in v9.02/9.03/9.04 if not changing interface settings immediately

after application start-up. (10963)

[ETH] Resolved issue causing reversed positive / negative 1

PPS TE measurement results at SyncTest application v5.00 and

later. (10907)

[ETH] Resolved issue in PacketTE measurement graph not

displayed when PTP StepMode setting is different between port

Page 18: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

18 TAA-1ETNMX0054-47

1 and port 2 in SyncTest application after v5.00. (10906)

[ETH] Resolved issue causing the Frame Count threshold to

Fail incorrectly within the Ethernet BER application from v7.02.

(9487)

[ETH][OTN] Resolved issue causing incorrect control of

QSFP28 optical modules with Power Class 5, 6, and 7 from

v9.00. (10903)

[ETH][OTN] Fixed bug when QSFP+/QSFP28 modules

selected causing incorrect display of all Tx powers in dBm units

instead of mA units; now either mA or dBm units displayed

according to optical module specifications. (10994)

[MxH] Resolved issue causing GUI display to not follow the

instrument change to CPRI when OBSAI setting has Delay or

APS measurement is enabled. (11080)

[SDHPDH] Resolved issue causing the unit to restart when

creating a report from an E1 measurement in the SDH/SONET

application from v3.0. (10962)

[Remote] Resolved issue preventing return of the correct status

information when using CFP, CFP2, CFP4, or QSFP28 optical

modules, when querying module status using SCPI commands.

(10893)

9.04 2018-04-04 Fixed bugs

[Framework] For MU100011A serial numbers 6261738768 to

6261801145, added function for automatically correcting default

MAC address of measurement port from "00-00-00-xx-xx-xx"

set a result of bug to "00-00-91-xx-xx-xx".

Upgrade customers using instruments affected by this problem

as soon as possible to this new version. (10966)

[Framework] Fixed bug when displaying history log (list of

previous input characters) at character input dialog causing

history log to overlay numeric input buttons and prevent ability

to press buttons. (11087)

[ETH] Fixed bug causing sending of ARP Request using

destination IP address instead of Gateway address when

executing ARP with Gateway set to ON with Ethernet

application v9.03 and later. (11209)

9.03 2018-02-22 Improvement

[Standard OTDR][FTTA][Construction] Improved the performance of

Page 19: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

19 TAA-1ETNMX0054-47

the connection check function when using a short patch code (3m or

less). (10980)

9.02 2017-12-06 Fixed bugs

[ETH] Fixed a bug of RFC6349 causing sometimes worse

throughput than actual DUT's performance. This bug only

happens MU100010A and MU110010A in v9.01. (10888)

9.01 2017-11-30 Key Added Features

[ETH] Added function for selecting MDI/MDI-X/Auto at

10M/100M/1000M Ethernet electrical interface. (10810)

[ETH] Added In-band Remote Function including Discovery

application to MT1100A. (10811)

[NOFRAME] Added 4LaneBER measurement function to

MU100011A. (10809)

[FTTA] Added function for loading CFG file to FTTA application.

(10762)

[Construction] Added function to Construction application to

reflect cursor position set at first wavelength at waveforms for

other wavelengths when measuring several wavelengths.

(10552)

[Framework] Added function for avoiding problem of delayed

main unit start-up resulting from saving of multiple files in

internal storage of measuring instrument. (10790)

[Remote][VIP] Added function for automatically appending .vipi

extension even when specifying output file name without

extension description when using [Save with File Name] at

MMEM:STOR remote command. (10682)

Fixed bugs

[ETH] Fixed bug causing incomplete display of measured result

decimal point values when measuring Latency of multiple ports

simultaneously at either BERT or MonGen application. (10789)

[ETH] Fixed bug causing settings change according to

dependence of Gateway On/Off setting on ARP On/Off setting.

(10791)

[ETH] Fixed bug causing inability to select IPv6 Frame setting

when selecting VLAN ID 2 at Ping application. (10737)

[ETH][OTN][SDH][FC][CPRI] Fixed bug causing output of space

separator at every three numerals when numeric data such as

bit count, etc., at report creation and output in .csv format.

Page 20: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

20 TAA-1ETNMX0054-47

(10728)

[NOFRAME] Fixed bug sometimes causing error generation at

20LaneBER measurement using QSFP28 module with

MU100011A module. (10797)

[OTN] Fixed bug causing incorrect 0 dBm display for tunable

wavelength SFP receive power. (10799)

[VIP] Fixed bug causing display of [Analysis Failure] dialog

instead of [Failed Test] dialog when saving failed evaluation

result data. (10773)

[Standard OTDR][Construction] Fixed bug causing Sequence

Number to become 0 when loading SOR file captured by Anritsu

OTDR (MT908x, MT9090, etc.). (10449)

[Standard OTDR][FTTA] Fixed bug causing test results to not be

reflected when displaying Test Status screen at OTDR and

FTTA applications. (10320)

[Standard OTDR][FTTA] Fixed bug sometimes causing blank

Setup screen List box when reading SOR captured by Anritsu

OTDR (MT908x, MT9090, etc.) using “Load with setup".

(10755)

[OLTS] Fixed bug causing non-display of OLTS progress bar

when Test Status screen displayed at OLTS application.

(10767)

[Remote][Standard OTDR] Fixed bug causing non-display of

VFL function key when starting client with INST:STAR:GUI after

starting OTDR application with SCPI. (10162)

[Remote][Standard OTDR] Fixed bug preventing correct

capture of dB/Km (fiber loss) when obtaining measurement

results using OTDR:TRACe:LOAD:TEXT? with measurement

conditions set to Automatic. (9409)

9.00 2017-09-19 Key Added Features

[New HW] Added CPRI RF Module MU100040B to

measurement module product line. (10764)

[ETH] Added FEC On/Off function to 25G Ethernet settings.

(10238)

[ETH][OTN] Added CFP2-QSFP28 Adaptor J1756A (10765)

[ETH][OTN][SDH][CPRI][FC] Added I2C analysis function for

SFP/SFP+/SFP28 Module. (10741)

Fixed bugs

Page 21: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

21 TAA-1ETNMX0054-47

[OTN][SDH] Fixed bug at APS test preventing APS

measurement for up to 2 seconds after measurement start.

(8937)

[Remote] Fixed bug causing incorrect PASS evaluation at

Summary Results at ARP failure at Y.1564 and Ping

applications under remote control.(9799)

8.02 2017-08-31 Key Added Features

[ETH][SDH] Added Line Rate Frequency deviation (Max., Min.,

Avg.) to the measurement items. (10715,10714)

[SDH] Added MS-AIS/AIS-L alarms into the Insert Alarm

function during Through Mode operation of the BERT

application. (10657)

[NOFRAME] Added No Frame application supporting the

following functions to the MU100011A Module. (10443)

- 25G BER for SFP28.

- 10G x4 lane BER for 40G QSFP+.

- 10G x20 lane BER for 100G CFP4/QSFP28.

[SEEK] Added Loop function and character divider command

for the MX100003A. (10691)

Fixed bugs

[ETH] Fixed bug preventing incorrect measurement of one-way

delay measurement results while using GPS connected to the

MU100090A and the Y.1564 application with V8.00/V.801.

(10733)

[ETH] Fixed bug preventing normal LOS Alarm information on

the Status screen when 25GbE is selected while using the

MU100011A module. (10732)

[ETH] Fixed bug preventing the selection of IPv6 within the Ping

application. (10722)

[ETH] Fixed bug preventing a FAIL test status when ARP failure

occurs in the Ping application. (9798)

[SDH][OTN] Fixed bug causing the display of incorrect Signal

Power value on the Status screen at 40G/100G line rates.

(10736)

[OTN] Fixed bug allowing the selection of LOS as an APS

measurement trigger condition when QSFP+/QSFP28 interface

is selected within the APS application. (10677)

[NOFRAME] Fixed bug preventing normal 20 Lane BER

Page 22: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

22 TAA-1ETNMX0054-47

measurement on the CFP2 interface while using the No Frame

application with the MU110013A module. (10676)

8.01 2017-06-29 Key Added Features

[ETH] Added function for stopping stream sending when Pause

Frame received at 100GbE/40GbE/25GbE. (9968)

[ETH][OTN][SDH][FC][CPRI] Added function to support the

Tunable SFP/SFP+. (9473)

[ETH][OTN][SDH][FC][CPRI] When the threshold value is set,

the color of the test result value is reflected in the PDF report.

(10173)

[ETH] At SyncTest application, changed so that PacketTE and

OWD graph magnified display performed within significant digit

range. (10504)

[OTDR] [FTTA] In Fiber Visualizer mode, added function for

displaying help to resolve issues when selecting Fail event icon.

[SEEK] Added following functions at scenario execution

function. (10484)

- Function for editing header information used at report output.

- Function for outputting results after scenario execution directly

to USB memory.

[VIP] Added exposure-compensation function to G0382.

(10354)

Fixed bugs

[ETH] With 100GbE FEC enabled, fixed bug causing PCS Skew

injection to be enabled when should not be enabled. (10451)

[ETH] At SyncTest application, fixed bug causing N/A display for

PacketTE measurement results. (10447)

[ETH] At Y1564 application when executing End-to-End

measurement, fixed bug causing main unit to restart when

frame received from port other than master port set at slave

port. (9622)

[ETH][OTN][SDH] At MU110013A, fixed bug causing main unit

to restart when I2C analysis function executed during

measurement. (10098)

[OTN] At QSFP28 interface, fixed bug preventing correct rate-

select setting for device. (10313)

[RemoteGUI] At MX100001A, fixed bug causing large font

display on screen. (9970)

Page 23: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

23 TAA-1ETNMX0054-47

[OTDR] [FTTA] [Construction] Fixed bug preventing input of

comma (,) period (.), forward slash (/), yen symbol (?), and

question mark (?) characters at header input screen. (10427)

[OTDR] [FTTA] Fixed bug causing initialization of calibration period

at software update. (10512)

8.00 2017-05-23 Key Added Features

[New HW] Added 100G Multirate Module MU100011A to

measurement module product line.

[Framework] Increased battery charge upper temperature limit

by 3°C. (9532)

[ETH] Added following functions to Sync Test Application

(10154) :

- Terr (min), Terr (max), max|Terr| measurement results

- 1PPS Mode for measuring packet base TE by the external

1PPS

- Function to reflect the UTC offset valve that the Grand Master

announces in broadcast message, when the network master

emulates PTP slave.

[CPRI] Separated CPRI and OBSAI GUIs for

easier-to-understand operation (9519)

[OTDR] Added real-time Check function to Construction

application (10244)

[SEEK] Changed response time-out default value after sending

remote command to 30 s (10374)

Fixed bugs

[ETH] Fixed bug causing main unit to restart when attempting to

display IEEE1588v2 Log when external logging enabled for

IEEE1588v2 function.(10107)

[ETH] At stream setting, fixed bug preventing obtaining of

source IPv4 address from DHCP server.(10226)

[ETH] Fixed bug sometimes causing unstable results when

measuring cables shorter than 10 m with cable test

application.(9477)

[FC] Fixed bug sometimes causing Frame loss when using

reflector application.(10214)

[VIP] Added SC/APC chip to selection list at G0382A usage screen

because not included in list.(10134)

7.05 2017-03-23 Key Added Features

Page 24: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

24 TAA-1ETNMX0054-47

[Framework] Added Quick Matrix to File input screen.

[Framework] Added support for saving/loading file names with

period (.) in file name. (9557)

[ETH] Added In-Band control function and Discovery

application. (9526)

[ETH] In RFC2544 application, upgraded to display a total of up

to 500 steps for measurement results, previously only displayed

up to 100 steps for each measurement. (8995)

[ETH] Added support to RFC254 application Burst test, allowing

configuration and displaying results in Burst seconds. (9385)

[ETH] Added support for Category 6/6a to Cable Test

application. (9474)

[ETH] [OTN] [SDH] [FC] [CPRI] On the SFP module information

display screen, change the wavelength display when mounting

Bi - Direction SFP to "Tx wavelength (Nominal)". (9520)

[FC] For FC, added performance test application(Perf. Test) to

run RFC2544-like benchmark tests. (9525)

[FC] For FC, added support for setting in Mbps units to Frame

Tx function. (8386)

[OTDR] Construction application, changed to output to only be

in SOR format files. (9560)

[Remote][ETH][OTN][SDH] Added transceiver control remote

commands support. (9530)

[SEEK] Added the following functions to MX100003A .(9752

- VIP application.

- Save file function by using a Variable.

- Quick Matrix function when specifying file name.

- Custom Application to Command Selection.

- Remove command allowing deleting of delete any characters

in a string.

[VIP] Added support for G0382A auto-focus VIP.

[VIP] Added following functions to VIP application.

- Auto-measurement function (auto-focus, auto-capture).

- Auto-recognition of probe connected to main frame.

(supports G0382A, and G0306A/B; G0382A only supports

auto-focus).

Fixed bugs

[Framework] Fixed bug causing MT1000A to freeze when

Page 25: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

25 TAA-1ETNMX0054-47

repetitive insertion/removal of G0306A/G0306B. (9850)

[ETH] Fixed bug in MonGen application causing restart when

terminating application while Threshold Summary screen

displayed. (9602)

[FC] Fixed bug in Reflector application causing Frame Loss at

Frame size of 8n + 4 (n = 8..267). (9231)

[OTN][SDH] Fixed bug in APS application causing switching

time to result in larger value, when set to a bit rate of 40 Gbps or

more and the trigger setting is pattern error. (9753)

[OTDR] Fixed bug preventing editing of user-registered macro

at Smart File Name. (9559)

[OTDR] Changed summary from Open to FAIL when far end not

detected. (9691)

[Remote][ETH] Fixed bug causing main frame to restart when

performing Through and Frameloss measurement of RFC2544

application via MX100001A. (9688)

[Remote][ETH] Fixed a bug causing the test application to stop

when using the stream copy function of Y1564, MonGen and

ChannelStat application via MX100001A, on the main unit it

caused a restart. (9797)

[Remote][ETH] Fixed bug allowing an unusable rate to be set via

SCPI control. (9601)

7.04 2017-02-20 Fixed bugs

[Framework] Fixed bug sometimes causing instrument reboot

when performing analysis using G0306A/B on VIP application.

(9627)

7.03 2017-01-05 Key Added Features

[ETH] Added support for two stacked VLAN to the Ping

application. (9472)

[Construction] Added setting for File Number Digit length

[FTTA] Added Manual measurement ability

[OLTS] Added Wave Code mode for auto measurement of

multiple wavelengths.

[OTDR][OLTS][FTTA][Construction] Added support for German

language in Optical fiber test applications.

[NoFrame] Added ability to save measurement results as

Report file to NoFrame application

[OTDR] Added support for PDF report generating for

Page 26: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

26 TAA-1ETNMX0054-47

Bi-Directional analysis result.

[OTDR] Added settings on Preference for Realtime

measurement.

Fixed bugs

[ETH] Fixed bug incorrectly enabling/disabling FEC switching

during 100G Ethernet measurement with MU110013A (9489)

[ETH] Fixed bug sometimes preventing correct sending of

received packet during instrument response to ARP/PING with

Ethernet Reflector (6965)

[ETH] Fixed bug, causing measurement screen to freeze

sometimes during PTP communications when PTP log function

is enabled (9424)

[ETH][OTN] Fixed bug causing lengthened time until event log

results displayed on screen (9370)

[Remote][OTN][SDH] Fixed bug sometimes causing option error

when setting RTD application Measurement Period using SCPI

command (9469)

[OTDR] Fixed bug when loading zip format waveform file at

Overlay condition causing screen top to display enabled (ON)

even when Bi-Directional setting changed automatically from

enabled to disabled. (9255)

[Remote] Fixed bug preventing SCPI commands of MDIO

control to work in applications except for NoFrame.(9493)

[Remote] Fixed bug sometimes preventing correct screen

enable/disable control when using SCPI remote control.(9481)

7.02 2016-10-28 Key Added Features

[ETH] Added Rate display for FEC counter (9401)

[ETH] Added I2C analysis function for QSFP28 module (9400)

[ETH] Changed initial graph display of 1PPS time error test from

Deviation to Phase Error (9313)

[GPS][MU100090A] Added function for displaying elapsed time

after lock to GPS (9068)

[NoFrame] Added function for setting different PRBS pattern at

each lane for 4Lane BER measurement function (9402)

[OTN] Added OTN test using QSFP28 module (9255)

[Remote][SEEK] Added command copy and paste functions for

MX100003A (9336)

[Remote][SEEK] Add support for OTDR application at scenario

Page 27: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

27 TAA-1ETNMX0054-47

creation using MX100003A (9454)

[SDH] Added AnyError to APS application trigger (9304)

[SDH] Added M0, M1, and Z2 byte setting and capture display

for OH Preset, and OH Capture function (9305)

Fixed bugs

[ETH] Corrected bug in Frame Capture function ≤10G causing a

packet whose timestamp data to be zero (9249)

[ETH] Corrected bug preventing reverse colors at OWD

threshold value evaluation in SyncTest application summary

screen (9323)

[ETH][OTN] Fixed bug at 40G/100G operation causing

initialization of inserted lane when changing Skew insertion lane

type (8839)

[ETH][OTN] Fixed bug in MU110012A preventing establishment

of Link when restarting application (8961)

[OTN] Fixed bug causing simultaneous SM-BIP8 insertion when

inserting AIS/OCI/LCK when operating at 40G/100G (9404)

[RemoteGUI] Fixed bug sometimes causing display of warning

message when quitting MX100001A (7222)

[Remote][ETH] Fixed bug sometimes preventing output of correct

measurement results when measuring Latency between Port1 and

Port2 using one measuring instrument under SCPI control (9389)

7.01 2016-10-11 Fixed bugs

[OTDR] Fixed an issue that prevented some MU100020A and

MU100021A OTDR modules from changing wavelength when

used in a low-temperature environment.

[OTDR] Fixed a bug that caused an error massage when

loading a configuration file(.cfg) created by MU100021A to

MU100020A or MU100022A.(9298)

[OTDR] Fixed a bug that could prevent remote control of the

OTDR modules when “Fail” was returned by connection

check.(9287)

[OTDR] Fixed a bug that received remote control commands

while running the Construction application.(9392)

[OTDR] Fixed a bug that caused an error when receiving the

OTDR:TRACe:TEXT? Command with an argument(s).(9393)

7.00 2016-09-14 Key Added Features

[New HW] Added New OTDR Module (MU100022A: 3wl.

Page 28: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

28 TAA-1ETNMX0054-47

1310/1550/1625nm model).

[ETH] Separated [Profile] and [Measurement Settings] tabs

included in [Stream] tab at BERT test into two separate tabs

labelled [Stream/Profile] and [Stream/Measurement Settings]

(9165)

[OTDR] Added Construction function.

[OTDR] Added Bi directional mode.

[New HW] Added CPRI RF Module.

Fixed bugs

[Framework] Supports simultaneous installation of three module

types.

[Framework] Fixed bug in GPS utility preventing monitoring of

GPS signal receive status.(9172)

[Framework] Fixed bug in File Explorer causing main frame to

restart when erasing file.(9099)

[Framework] Fixed bug preventing display by laser emitting

indicator during measurement when Standard OTDR

application started after VIP started.(9144)

[ETH] Fixed bug causing incorrect Frame Loss rate calculation

when Total Repeat Steps set to ON at RFC2544 test.(6445)

[ETH] Fixed bug in Sync Test application preventing input of

negative value as one-way Delay Threshold value.(9235)

[FC] Fixed bug causing incorrect display of Frame Loss

Seconds and Pattern Loss Seconds even when Frame Loss

Seconds set to Ignore at BERT application.(9173)

[OTDR] Fixed bug preventing execution of Standard OTDR

Mission Control Power Meter Offset Zero function. (9217)

[OTDR] Fixed bug causing main frame to restart when opening

OTDR results file with Result File Browser when no OTDR

module installed in main frame. (8836)

[OTDR] Fixed bug in OTDR application preventing display of

Fiber Visualizer screen waveform window when far end not

found. (8806)

[OTDR] Fixed bug causing VFL to light for several seconds

when application quit and then restarted while VFL in ON

status. (8968)

6.02 2016-08-15 Key Added Features

[ETH] Changed specification for PRBS Sync Alarm and PRBS

Page 29: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

29 TAA-1ETNMX0054-47

Pattern Error detection immediately after measurement start at

BER measurement using Ethernet BER application Cross

PRBS pattern (9130)

[OTN][SDH] Added measurement ON/OFF setting for following

items: (9062)

OTN: PLM

SDH/SONE: HP=PLM, LP-PLM, Threshold Alarm

[SDH] Added Generic-AIS detection function (8555)

Fixed bugs

[OTDR] Fixed bug in v6.00 causing display of "Include

Performance Verification data" checkmark at report generation

screen for results not actually displayed (9141)

6.01 2016-07-14 Fixed bugs

[ETH][OTN] Fixed bug preventing correct CFP Module

Transceiver setting and causing error when using V6.00

software with MU110011A CFP Interface (9116)

[FC] Fixed bug causing periodic Frame Loss when sending

FC1200 Frame signal (7877)

[OTN] Fixed bug in V5.01 and later software causing doubling of

output clock frequency when selecting any one of OTU1f/2f/2e

bit rates when using Tx Reference Clock Output with

MU110010A (9084)

[FTTA] Fixed bug causing disabled software key when moving

to TRACE tab at TTA application after starting measurement

(9138)

6.00 2016-06-23 Key Added Features

[New HW] Added MU110013A module and dedicated option

[Framework] Added autosave function for MT1100A CFP/CPF2

Interface transceiver settings (8568)

[ETH] Added following settings to Traffic Tx function

・Burst Tx Setting

・Frame Length Increment Tx

・Tx Rate Inter-Frame Gap Specification

・Tx Rate Millisecond Unit Lamp Tx Setting

・Tx Rate over 100% stream Setting

[ETH] Added Cross PRBS pattern setting to Payload patterns

for BERT Application

[ETH] Added function for automatically allocating IPv6 Tx

Page 30: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

30 TAA-1ETNMX0054-47

source address using RS/RA function

[OTDR] Added function for SCPI Remote command control to

OTDR application

Fixed bugs

[Framework] Fixed bug causing restart of main frame when

inputting "e" character while file load/save dialog displayed

(8873)

[Framework] Fixed bug causing license error display when

loading settings file saved by MT1000A+MU100010A

configuration at MT1000A+MU1000xxA+MU100010A

configuration and corrected notification to comment on

configuration difference (8633)

[ETH] Fixed bug causing non-stop sending at Pause Frame

receiving even when Auto Negotiation set to off for

10/100/1000M electrical interface and "Respond to Pause

Frame" set (8643)

[ETH] Fixed bug causing output of all selection items when

outputting test results to CSV or XML file using Channel

Statistics application (8523)

[ETH] Fixed bug causing inclusion of MPLS label value in

Address Filter Stream ID conditions using Mon/Gen application

(8543)

[ETH] Fixed bug causing Skew value to be displayed as

">0.000" and incorrect measurement when selecting any

Interval result at "Relative Skew" results display of Result

screen (8838)

[ETH] Fixed bug preventing correct display of result table

service details at measurement results for Y1564 (8527)

[FC] Fixed bug causing monitoring of Frame Loss seconds even

when "ignore Frame Loss seconds for BERT measurement

results" set at BERT application (8730)

[PTP] Fixed bug causing locking for only up to 4 hours in locking

state using GPS utility. (8548)

[OTDR] Fixed bug sometimes causing error in Reflectance analysis

results when Auto Mode Test set to Advanced. (8933)

5.04

5.03

2016-05-23 Key Added Features

[Framework] Added the One-Button Test.

Fixed bugs

Page 31: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

31 TAA-1ETNMX0054-47

[Framework] Fixed bug causing the unavailable access to USB

stick after the specific procedure on V5.01.(8826)

[Framework] Fixed bug causing main frame to restart when

USB memory stick removed while File Manager focused on

sub-folder in inserted USB memory.(8733)

[ETH] Fixed bug causing the application crashes when outputting

report of Ethernet RFC 2544 ”End to end network test” results

(8614)

5.01 2016-03-25 Key Added Features

[Framework] Added to fiberscope with 60 degrees tip (7961)

[OTDR] Expanded maximum settable pulse width for each

distance range (8044)

[OTDR] Changed dummy fiber (launch spool) display color to

clearly show the start of the fiber under test. (8045)

[ETH] Added auto MAC address resolution function when a

generating IPv6 Stream (NDP NS/NA) (7712)

[ETH] Added possibility to ignore Frame loss seconds count in

Ethernet BERT application (8057)

[ETH] In SyncTest application, added calibration parameter for

GPS antenna cable length. (8026)

[ETH] In SyncTest application, added high-resolution frequency

counter function (7945)

[OTN] Added LOS insertion function (7366)

[OTN] Added following APS trigger items (7775)

OTU3x/4: FAS-OTL, LOF-OTL, OOF-OTL, LOR-OTL, OOR-OTL,

OTU1x/2x/3x/4: OTU-AIS, OOM

[SDH] Added possibility to disable the display of Pointer

Movement measurements (7905)

Fixed bugs

[Framework] Fixed bug when disabling WLAN sometimes

causing instrument to temporarily freeze (8272)

[Framework] Fixed bug causing the NWM Flex with battery

option MU11001A from fully shutting down.(8391)

[Framework] Fixed the problem that MU100090A power On/Off

status isn’t stored properly occasionally. (8273)

[OTDR] Fixed bug that "Restore Default" operation does not

work after creating OTDR report.(8448)

[ETH] Fixed bug for 10GbE sometimes causing transmitter to

Page 32: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

32 TAA-1ETNMX0054-47

insert wrong IFG (7673)

[ETH] Fixed bug in IEEE1588 function sometimes causing UDP

checksum errors in transmitted PTP frames (7835)

[OTN] Fixed problem when starting applications with +OTN

option sometimes causing invalid option warning message

(7683)

[OTN][ETH] Fixed bug in Ethernet transmitter causing BER

alarm when Ethernet mapped over OTN using GFP-F.

(7519)(8075)

[OTN][ETH] Fixed bug causing BER alarms for MPLS mapped over

OTN using 46 byte frame size. (7844)

5.00 2016-02-19 Key Added Features

Added MU100090A Module

[ETH] Added IEEE1588 Time error measurement function.

(7892)

[ETH] Added ITU-T8275.1 profile for IEEE1588 functions

(7992)

[CPRI] Added APS measurement function to BERT application

(7099)

[Framework] Expanded MDIO Analysis functions for

CFP/CFP2/CFP4. (7976)

[OTN] Added mappings for packet based client signal.

(7975,7977,7978)

[OTN][SDH] Added BERT/APS/RTD switch mode to BERT

application (7980)

[OTN][SDH] Added SDH Transparent mapping for SDH over

OTN start (7981)

[Remote] Added support for VNC control via HTTP with JAVA

1.8 (6353)

[Remote] Added support for simultaneous SCPI and Remote

GUI control (7681)

[Remote][ETH] Added remote command for specifying save

destination for IEEE1588/SyncE Frame capture data (8198)

- ETH:PORT1:PTP:FCAP:DIR

[Remote][ETH] Added following remote commands for

performing IEEE1588 ARP analysis and querying analysis

results (8157)

- ETHernet:PORT<Pt>:PTP:MAC:ARP

Page 33: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

33 TAA-1ETNMX0054-47

- ETHernet:PORT<Pt>:PTP:MAC:ARP:RESult?

Fixed bugs

[OTDR] Upgraded Event (fault point) detection (search)

accuracy (8034)

[Framework] Fixed problem causing Chinese and Japanese

UTF-8 encoded CSV reports to display garbage characters

when opened in MS-Excel. (7750)

Japanese: UTF-8 to Shift JIS

Chinese: UTF-8 to GB2312

[Framework] Fixed bug preventing re-acquisition of IP address

when switching WLAN access point (7360)

[Framework] Simplified Password dialog and fixed problem

when initially enabling system password protection requiring

user to know old (default) password. (7551)

[Framework] Fixed bug causing sudden shutdown when starting

with remaining battery charge of ≤6% (7662)

[ETH] Fixed bug only permitting insertion of less than directed

block errors when inserting errors while testing at Frame rates

of >2000 bytes when testing at interface of10/40/100 Gbps

(7020)

[ETH] Fixed bug causing Frame loss when receiving IPv4 +

UDP header Ethernet Frame when Frame length not multiple of

8 bytes at 40/100GbE (7836)

[ETH] Fixed bug restricting the minimum payload size of

38-byte when selecting custom header at BERT application

stream setting (7725)

[ETH] Fixed bug causing [Timing: Bit rate Difference] to remain

unchanged at 0 even when clearing History at Ethernet test

(6884)

[ETH] Fixed bug causing IEEE15888 status Wall Clock Current

time affects from local MT1000A time setting (7850)

[ETH] Fixed bug causing sending of incorrect time data at

IEEE1588 communications (7715)

[ETH] Fixed bug causing display of NMX_WARNING message

when starting Ethernet application when 100GbE option

installed with MT1100A+MU110011A+MU110012A

configuration (7904)

[ETH] Fixed bug causing main frame to reboot when switching

Page 34: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

34 TAA-1ETNMX0054-47

BERT application custom header settings when loading settings

file saved with V2.xx when using V3.03 software (7894)

[ETH] Fixed bug causing display of NMX_WARNING message

when executing ARP on IEEE1588 function (8112)

[ETH] Fixed bug causing IP header protocol type field setting to

become UDP(0x11) or TCP(0x06) automatically after previous

setting when None set after setting Frame Format Layer 4 to

either TCP or UDP (7777)

[OTN] Fixed bug causing display of screen for making additions

when low-order ODU errors and alarms cannot be inserted at

OTN through-mode test (6950),(6643)

[Remote] Fixed bug preventing release of port resources even

when executing INST:TERM command (7369)

[Remote] Fixed bug preventing normal termination processing

of application when using multiple user control by SCPI

command (7816,7847,7029,7968)

[Remote] Fixed bugs causing MX100001A to crash at following

operations. (7933)

(1) At remote connection from MX100001A when measuring instrument

Remote PC connection set to OFF

(2) When changing measuring instrument Remote PC connection setting

from OFF to ON

(3) At remote connection from MX100001A

[Remote][ETH] Removed explanation of following unsupported

commands: (7537)

- ETHernet:CSTat:SETup:PORT<Pt>:PSELect

- ETHernet:CSTat:SETup:PORT<Pt>:PWIDth?

[Remote][OTN] Fixed bug preventing correct reading of PSI[0]

value using OH capture remote query command (7788)

[SDH/SONET] Fixed bug preventing reflection of measured

error in test results during measurement with APS application

(6982)

[Wireshark] Fixed bug causing Wireshark restart when reading

file format not supported by Wireshark (7595)

4.00 2015-12-10 Key Added Features

[NewHW] Added New OTDR Module for MT1000A

MU100020A OTDR Module 1310/1550 nm SMF

MU100021A OTDR Module 1310/1550/850/1300 nm SMF/MMF

Page 35: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

35 TAA-1ETNMX0054-47

Fixed bugs

[Framework] Fixed problem causing Chinese and Japanese

UTF-8 encoded CSV reports to display garbage characters

when opened in MS-Excel.

Japanese: UTF-8 to Shift JIS

Chinese: UTF-8 to GB2312

[Framework] Simplified Password dialog and fixed problem

when initially enabling system password protection requiring

user to know old (default) password.

[ETH] Fixed problem in RFC2544 application causing

instrument to restart when transmitting IPv6 formatted Learning

Frames. (7808)

[ETH] Fixed problem preventing saving of PTP message logs at

IEEE 1588v2 log. (7421)

[ETH] Fixed problem running 10G with frame sizes above 2000

bytes, sometimes preventing insertion of sufficient block errors

using error insertion function. (7020)

[OTN] Fixed problem reading PSI[0] OH byte (Payload type)

using SCPI command. (7788)

3.04 2015-11-06 Fixed bugs

[OTN] Fixed bug preventing normal detection at continuous

OLA alarm (7703)

[OTN] Fixed problem preventing PM-BIP and PM-BEI errors

being reported in Event Log. (7702)

[OTN] [ETH] Fixed problem causing Warning message while

re-loading settings file generated in an Ethernet over OTN

application. (7727)

[ETH] Fixed problem causing instrument to restart when using

Layer 2 custom header and exceeding the setup frame length

by enabling either Jitter or Latency measurement. (7674)

[ETH] Fixed problem with Latency result sometimes being incorrect

when measuring between two ports on same module. (7691)

3.03 2015-10-02 Key Added Features

[Remote] Added Remote Commands and GPIB-USB converter.

[ETH] Added Function for Custom Editing of Ethernet Header.

[ETH] Added Function for PCS at 10 GbE.

[ETH] Added Function for continues Stream address Creation.

[OTN] Added Null to Client Signals for OTN Mappings.

Page 36: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

36 TAA-1ETNMX0054-47

[ETH] Enhanced RFC2544 GUI for Easier Access and Better

Overview.

[ETH] Enhanced RFC2544/Y.1564 Reporting Providing More

Information.

[ETH] Renamed 'CFI' bit in VLAG tag to 'DEI' according to 2015

version of IEEE802.1Q.

[Framework] Improved Report Layout: Better Look and Distinct

Header Styles.

[Framework] Added Function for Filtering Results Display at

Report Output.

Fixed Bugs

[Framework] Fixed problem with removing USB storage while

viewing PDF or XML file stored on device (7359)

[Framework] Fixed problem with garbage characters sometimes

occurring in Japanese PDF reports created using MX100001A

Control Software and read under Windows 7 64-bit OS

environment (7028)

[ETH] Fixed problem with IEEE 1588 Log sometimes repeating

old events. (7390)

[ETH] Fixed problem with PTP clock system when running high

rates of Sync/Announce/Delay Request packets for IEEE 1588

protocol data (7389)

[ETH] Fixed problem with 40/100G Reflector application

causing statistics engine to drop frames when swapping of

IP/MAC disabled (7376)

[ETH] Fixed problem initiating OAM 802.ah Remote Loopback

on Accedian NIDs (7365)

[ETH] Fixed problem with Disruption errors sometimes reported

in Event Log while running RFC 2544 Latency Test (7361)

[ETH] Fixed problem with Pass-Through application running

GbE electrical causing dropped frames when changing clock

advertisement (master/slave) configuration (7284)

[ETH] Fixed problem with storing RFC 2544 result files when

test includes more than 148 steps (7136)

[ETH] Fixed problem with the Unicast/Multicast Tx frame

counters on "Ethernet - Transmit" statistics page not updating

when U/L bit of destination MAC address set (7108)(7103)

[ETH] When using GPS as Master Clock reference for

Page 37: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

37 TAA-1ETNMX0054-47

IEEE1588v2, fixed problem with current Wall Clock differing

from displayed UTC time (6996)

[ETH] For RFC 2544 and SAT (Y.1564) applications running

end-to-end network test, fixed problem with “Abort” window

remaining on slave after test finishes (6957)

[ETH] For SAT Y.1564 and Mon/Gen. applications, fixed

problem with automatically stored settings files potentially

causing applications to fail when re-launched (6956)(7529)

[ETH] Solved problem with disabling SyncE sometimes

leaving pending SSF Alarm History and Event Log entry (6912)

[ETH] Fixed problem with local port losing link when inserting

"No Link" alarm, although incoming signal OK (6877)

[ETH] Corrected table headings in RFC 2544 Latency report

when "Measure jitter by means of Latency test" enabled (7538)

[OTN] Fixed problem with not showing correct values for GMP

Justification Max/Min Cm. (7482)

[OTN] Fixed problem when using multistage mapping on OTN

where "false" LOFLOM alarms sometimes reported on

lower-order ODUs (7006)

[PDH] Fixed problem on E1 interface when Distant and No CAS

MFAS alarms sometimes also insert pattern errors (7019)

[SDH/SONET] Fixed problem with duplication of APS detailed

results when switching between ports (7382)

[Remote][NoFrame] Fixed problem setting Frequency Offset via

SCPI: NFRame:PORT<Pt>:STIMuli:TX:FOFFset <offset>

(7465)

[Remote] Fixed problem with instrument potentially

freezing/restarting when SCPI session closed immediately after

starting or terminating application server (7012) (7347)

[Remote] Fixed problem copying multiple files simultaneously to

PC from MT1000A/MT1100A using MX100001A Remote

Control Software (6986)

[Remote][CPRI] Fixed problem using

MEASurement:SETup:EVALuation:RX:INTerface?

command in CPRI BERT application (6992)"

[Remote][CPRI] When running CPRI Pass-Through application,

fixed problem preventing use of SCPI commands for setting

evaluation of measurement results (7042)

Page 38: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

38 TAA-1ETNMX0054-47

MEASurement:SETup:EVALuation:RX<Pt>[:ENABle]

MEASurement:SETup:EVALuation:RX<Pt>:INTerface

MEASurement:SETup:EVALuation:CPRI:PORT<Pt>:ITEM

MEASurement:SETup:EVALuation:CPRI:PORT<Pt>:ITEM:ALARm

MEASurement:SETup:EVALuation:CPRI:PORT<Pt>:ITEM:ERRor

MEASurement:SETup:EVALuation:CPRI:PORT<Pt>:TYPE

MEASurement:SETup:EVALuation:CPRI:PORT<Pt>:CNT:FAIL

MEASurement:SETup:EVALuation:CPRI:PORT<Pt>:RATio:PASS

MEASurement:SETup:EVALuation:CPRI:PORT<Pt>:RATio:FAIL

MEASurement:SETup:EVALuation:TMBPs:RX<Pt>:ITEM"

[Remote][ETH] Fixed problem with SCPI command for setting

stimuli alarm state (ETHernet:POER<Pt>:STIMuli:ALARm)

unnecessarily resetting electrical PHY, causing link loss for

several seconds (6993)

[Remote][OTN] When configured via SCPI remote control, fixed

problem with Ethernet client not obtaining link when mapped to

OTU3/4 using GFP-T (6955)

[OTN] Fixed problem using SCPI MAX and DEF parameter

values for setting Error Bits for GMP JC1/JC2 Error Items

(6775)

OTN:STIM:TX1:GMP:AEIN:EBIT MAX

OTN:STIM:TX1:GMP:AEIN:EBIT DEF

3.02 2015-07-29 Fixed Bugs

[Framework] Fixed Problem of Incorrectly Loading

Configuration File made Using MT1000A/MT1100A with

Different Options.(7110,7053,7038,7000)

[Framework] Using Remote GUI Software (MX100001A), Fixed

Problem Causing Inability to Start Editor and Viewer.(6990)

[ETH] Removed “Communication Port” for RFC 6349

End-to-End Test.(7172)

[ETH] Fixed Problem of Failing to Reflect “Expected preamble

length” Value at Loading Configuration File for Ethernet Pass

Through Application.(7156)

[ETH] Using Ethernet BERT Application, Fixed Problem of

Incorrect File Save/Read when Stream Setting for Port 2 and

Later Ports set to Unframed.(7041)

[ETH] Using Ethernet application, fixed problem causing

inability to reboot main frame when sending following query

Page 39: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

39 TAA-1ETNMX0054-47

commands and quitting application.(7022)

ETHernet:PORT<Pt>:OAM:DISCovery:CATalog?

[ETH] Fixed Problem of Disappearing Latency Results when

Saving and Loading Latency/Burst Result using RFC 2544

Application.(7010)

[ETH] Using Ethernet BERT Application, Fixed Problem

Causing Frame Loss when Reading V2.04 Settings File.(7004)

[ETH] After executing Ethernet Ping function, fixed problem

causing reboot when executing other Ethernet

application.(6999)

[ETH] Using Ethernet Application, Fixed Problem Causing

Screen Freeze when Sending/Receiving OAM 802.1ag/VLAN

CCM.(6980)

[ETH] Added following query parameters to SCPI

commands.(6975)

ETHernet:PORT<Pt>:IFETch?

TDL: Stream 1 Throughput Data Layer (bps). Response:

<Min>,<Max>,<Avg>

TNL: Stream 1 Throughput Network Layer (bps). Response:

<Min>,<Max>,<Avg>

TLL: Stream 1 Throughput Link Layer (bps). Response:

<Min>,<Max>,<Avg>

TPPL: Stream 1 Throughput Physical Layer without Preamble (bps).

Response: <Min>,<Max>,<Avg>

TPL: Stream 1 Throughput Physical Layer (bps). Response:

<Min>,<Max>,<Avg>

TUL: Stream 1 Throughput Utilization Layer (bps). Response:

<Min>,<Max>,<Avg>

[ETH] Using Ethernet Application, at ARP Reply Sending, Fixed

Rare Problem Causing Sending of Excess Stream Data in 1

Frame.(6970)

[ETH] Using Ethernet Application, Fixed Problem Sometimes

Blocked Correct traffic with "Include addresses in frame filter on

receiver" Settings at Rx Operation.(6964)

[OTN] Fixed Problem of Wrongly Configuring FC800 at Loading

of FC400 Configuration File for FC BERT over OTN.(7169)

[OTN] Fixed Boot Failure Problem of FC BERT over OTN

Application.(7166)

Page 40: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

40 TAA-1ETNMX0054-47

[OTN] Fixed problem causing no response when sending

OTN:RX<Pt>:IFET ch? S0MSIM SCPI command.(7066)

[OTN] Using OTN Application, Fixed Problem of Wrongly

Displaying MSIM Results Without Masking even at Higher-Level

Alarm.(7066)

[OTN] Using OTN application, fixed problem of incorrectly

reading Performance measurement results using SCPI

command when reading V2.02 or earlier results file.(7066)

[OTN] Fixed Problem Causing Higher-Level Summary LEDs to

Light when cHEC and tHEC Errors Detected at GFP-F/T

Mapping of OTN Application.(6972)

[OTN] Fixed Problem of Failing to Count Justification when

LOFLOM Detected using OTN Application.(6962)

[SDHPDH] Changed mistakes in SCPI command parameter

names.(7140)

T1:RX<Pt>:IFETch? (NFRame) -> (OOF)

T1:APS:RX<Pt>:EVENt NFR -> OOF

T1:STATus:RX<Pt>:ALARm? Loss Of Frame -> OOF

TMBPs:APS:RX<Pt>:EVENt NFR -> NFRame

- similar GUI value "LOF"-> "No frame"

[SDHPDH] Using SDH/PDH application, fixed problem of

inability to reboot main frame when sending following query

commands and quitting application.(7031)

E3:RX1:IFET? (PBBE)

[SDHPDH] Added E1 Balanced connector pin assignments to

manual.(6958)

[SDHPDH] Fix problem causing reboot when loading settings

file with set PDH rate at MU110011A module.(6915)

problem preventing use of threshold parameters set by

following SCPI commands at evaluation of actual measurement

results.(7042)

MEASurement:SETup:EVALuation:RX$<$Pt$>$[:ENABle]

MEASurement:SETup:EVALuation:RX$<$Pt$>$:INTerface

MEASurement:SETup:EVALuation:CPRI:PORT$<$Pt$>$:ITEM

MEASurement:SETup:EVALuation:CPRI:PORT$<$Pt$>$:ITEM:ALARm

MEASurement:SETup:EVALuation:CPRI:PORT$<$Pt$>$:ITEM:ERRor

MEASurement:SETup:EVALuation:CPRI:PORT$<$Pt$>$:TYPE

MEASurement:SETup:EVALuation:CPRI:PORT$<$Pt$>$:CNT:FAIL

Page 41: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

41 TAA-1ETNMX0054-47

MEASurement:SETup:EVALuation:CPRI:PORT$<$Pt$>$:RATio:PASS

MEASurement:SETup:EVALuation:CPRI:PORT$<$Pt$>$:RATio:FAIL

MEASurement:SETup:EVALuation:TMBPs:RX$<$Pt$>$:ITEM

[CPRI] Fixed Problem of Incorrect RTD Result Display at Each

Testing Interval of CPRI BERT Application.(6875)

[FC] Fixed Problem of Missing CRC Error in Errors/Alarms List

of Fibre Channel BERT Application.(6862)

3.01 2015-06-05 Key Added Features

[All] Added Error/Alarm indication summary.(6888)

[All] Added Performance Verification date in test report.(6890)

[All] Added Spanish Language support.(6891)

[Framework] Added the functionality of Storage

formatting.(6895)

[RemoteGUI] Added "Settings Editor" and "Result Viewer" on

MX100001A (Windows application).(6894, 6942)

[ETH] Added the functionality of “ Answering ARP/PING

request” and reflector MAC/IP address settings on Reflector

application. (6897)

[OTN] Added the client signal frequency result.(6887, 6868)

[OTN] Added “Pattern Bit Error Trigger” and ”LOS Trigger” on

APS application. (6867)

[ETH] Added “LOS” as a Ethernet Service Disruption test type

for optical interfaces

Fixed Bugs

[Framework] Fixed battery display information to show correctly

on MU110001A. (6902)

[RemoteGUI] Fixed the problem regarding sorting files on

windows application.(6878)

[ETH] Fixed the problem regarding SCPI command for stream

Line load. (6866)

[ETH] Fixed the problem regarding multi stream measurement

on Mon/Gen application. (6940)

[ETH] Fixed the problem regarding SDT(Service Disruption

Time) result. (6857)

[ETH] Fixed the problem regarding long term measurement on

PING application. (6834)

[ETH] Fixed the problem regarding the variable field of VLAN

Page 42: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

42 TAA-1ETNMX0054-47

ID. (6860)

[ETH] Fixed the problem regarding Remote Fault on Electrical

Interface.(6859)

[ETH] Fixed the problem regarding the maximum rate(CIR/EIR)

on 40/100G Y.1564 application. (6855, 4246)

[FC] Fixed the problem regarding SDT(Service Disruption Time)

result. (6863)

[FC] Fixed the problem regarding “Frame Loss Seconds” result.

(6864)

[OTN] Fixed application crash issue when starting a

measurement with threshold enabled. (6939)

[OTN] Improved regarding frequency offset.(6887)

3.00 2015-05-25 Added CPRI applications.(6465)

Added following functions to Ethernet applications:

Added RFC6349 application.(6366)

Added Layer 2 frame format support on Y.1564

application.(6398)

Added automatic service name on Y.1564 application.(6360)

Added “Include addresses in frame filter on receiver ON/OFF”

on RFC2544/Y.1564/MonGen applications.(6557)

Added following functions to OTN applications:

Added 3stage mapping on OTU3/4.(6369)

Added BMP mapping of SDH client.(6372)

Added FTFL alarm insertion/detection.(6373)

Improved the setting order of OTN Client.(6374)

Supported GFP-F Client signal up to 100G.(6369)

Added Error/Alarm statistics on APS application.(6399)

Added following functions to SDH applications:

Added Pattern Error Trigger on APS application.(6419)

Added Error/Alarm statistics on APS application.(6399)

Added following functions to FC applications:

Added Frequency offset Insertion/Monitor.(6405)

Added Reflector application.

Added following common functions:

Added GUI remote functionality from PC.(6342,6341)

Added Event Log functionality.(6400)

Added VIP application on Utility.(6367)

Added MDIO analysis functionality for CFP module.(6351)

Page 43: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

43 TAA-1ETNMX0054-47

Added electrical extender module support.(6483)

Added external 10MHz clock support.(6464)

Added Emphasis and Equalizer functionality for

CFP/CFP2.(6352)

Added Swedish keyboard input support.(6345)

Added CSV format report support.(6340)

Improved Utility Icon visualization.(6365,6362,6361)

Fixed Bugs [All] Fixed the problem that CFP2 interface may not

work correctly when configuring the timing source,

"Received".(6667)

[All] Fixed the problem that MT1100 which mounts MU110010A

sometimes shutdown when launching with battery.(6880)

[SCPI] Fixed the problem of Measurement Stop just after

Measurement Start.(6726)

[SCPI] Improved the stability of long term SCPI running.(6707)

[ETH] Fixed the problem that MPLS-TP result does not count up

when MPLS-TP OAM frame received.(6762)

[ETH] Fixed the problem regarding E2E communication

between MT1000/MT1100 and CMA3K on RFC2544

application.(6735)

[ETH] Fixed the problem regarding selection of throughput type

on RFC2544 application.(6658)

[ETH] Improved the stability of long term running on RFC2544

application.(6656, 6644)

[ETH] Fixed the problem that SDT result resets when LOS

detected.(6570)

[ETH] Fixed the problem regarding PCS alarm LED.(5892)

[OTN] Fixed the problem regarding the mapping for 10GbE into

ODU2e, mapping procedure is AMP (Asynchronous CBR

Mapping). (6372)

[SDH] Fixed the problem regarding Performance

measurement.(5419)

[FC] Fixed the problem regarding SDT measurement.(6531)

[FC] Fixed the problem that undersize frame sometimes

counts.(6254)

[NoFrame] Fixed the problem regarding the BERT

measurement result on NoFrame application.(6733)

Page 44: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

44 TAA-1ETNMX0054-47

[ETH] Default setting of throughput calculation layer is changed

on RFC 2544

[ETH] Fixed the process of handling larger test results than the

available storage on RFC 2544

[ETH] RFC 2544 “Average Throughput” test calculation fixed by

only calculating during a stable data stream

2.05 2015-03-25 Bug fixes and Improvements

[OTN] Fixed the problem regarding the error on OUT3-40GbE

mapping.(6454)

[All] Fixed the problem on MU110001A without battery

operation. (Bug only for ver. 2.04) (6411)

[All] Fixed the problem that application crashed after long term

running.(6455, 6552)

[All] Fixed the problem regarding the network configure on the

Ethernet Service Interface.(6461)

2.04 2015-01-22 Enhancements

[SCPI] Added the launching GUI command and the functionality

of switching control between the GUI and Remote.(6355)

[PDH] Added the PRBS31 test pattern on E3.(6064)

Bug fixes and Improvements

[OTN] Fixed the problem regarding through mode.(6386)

[OTN] Fixed the problem regarding the Performance

measurement. (6264)

[OTN] Fixed the problem regarding the OTN payload type

setting/detection for ODU4-ODU2e-10GE mapping. (6401)

[ETH] Fixed the problem regarding transmitting stream on

40/100G.(6281)

[ALL] Improved the stability when measuring.(6376,6229)

2.03 2014-12-18 Bug fixes and improvements

[OTN] Added some Errors (LLM-OTL, MFAS-OTL). (6262)

[OTN] Added some Error Trigger Type on APS measurement.

(6261)

[OTN] Changed the name of some Errors. (OTL, LOA, LOBL,

LOAML) (6262)

[SDH] Improved the updating results on Pointer Movement

measurement. (6265)

[ETH] Fixed the problem regarding the showing service number

Page 45: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

45 TAA-1ETNMX0054-47

on Y1564 application. (6295)

[ETH] Fixed the problem of End to End measurement on Y.1564

application. (6291)

[ETH] Fixed the problem that HiBER is not detected. (6230)

[FW] Fixed the problem regarding the VNC connections. (6243)

[FW] Fixed the problem regarding the Battery information on

MT1100.(6020)

[RFS] Supported ETSI R&TTE EN300 328 V1.8.1. (6263)

[RFS] Improved the stability on all applications. (6318)

[RFS] Improved the stability of the Ethernet Service Interface.

(6404)

2.02 2014-11-11 Bug fixes and improvements

[OTN] Fixed the bug which is on decode of ITU-T G709

PSI[0].(6231)

[ETH] Fixed the bug that NMX_ASSERT is sometimes

occurred. (6232)

[FC] Fixed the bugs which are interoperability issue and some

minor issues. (5088, 6253, 6254)

[Wireshark] Fixed the bugs and improved the stability.(6166)

2.01 2014-10-23 Support for the following products:

MT1100A Network Master Flex Main frame

MU110010A 10G Multirate Module

MU110011A 100G Multirate Module

MU110012A 40/100G Module CFP2

Added Fibre Channel applications

Added following functions to Ethernet applications:

Support for WAN-PHY interface

Frame capture include Wireshark

Channel Statistics

Added following functions to OTN applications:

GFP-F mapping

FC client mapping

Bug fixes and improvements

1.00 2014-06-23 Initial release. Support for the following products:

MT100A Network Master Pro Main frame

MU100010A 10G Multirate Module

Page 46: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

46 TAA-1ETNMX0054-47

Known Problems

Version Description

MT1000/MT1100

MU100010A

MU100011A

MU110010A

MU110011A

MU110012A

MU110013A

V10.03 [ETH] Service Disruption Time result is ±300 ms

measurement accuracy when using CFP2 interface of

Ethernet BERT application. (6858)

[ETH] [MxH] With Ethernet or eCPRI/RoE BERT

applications, screen may freeze at measurements including

UDP packets when receiving UDP packets at different

destination port than source port setting. This bug occurs

only at Port 1; if this bug occurs, restart the MT1000A as a

workaround solution. (12575)

[MxH] Pass-through delay for CPRI interface depends on

previous port mode setting. The Pass-through delay which

previous port mode is OFF is three times than the previous

port mode is NORMAL. (6876)

[SDH/SONET] Resolved issue in APS measurement

application after v7.02. On selecting Any Error as a trigger

the measurement result detected was about 10ms longer

than the actual switching time. (10849)

[ETH] Bug may cause Error frames when Line Rate higher

than 99.4% at Frame Size of 15500 bytes when performing

RFC2544 test with MT1100A 40G/100G interface. (9671)

[Remote] Bug may cause MT1000A mis-operation when

performing continued packet capture at remote operation

using MU100010A. (10942)

[ETH] Frame loss confirmed at RFC2544 test when using

v9.12, v9.13, and v10.00. (12818)

[ETH] Bug may prevent error recognition when receiving

ICMP reply packets including error with packet length of

more than 463 bytes. (12819)

[ETH][MxH] Fixed bug causing display of smaller than true

measured service loss time when [LOS] selected as

measurement type at MT1000A Ethernet BERT and

eCPRI/RoE BERT applications; bug avoided by selecting

[Ver. 9.05 or earlier] for latency/jitter timestamp. (13429)

[ETH] Fixed bug causing Ping application crash when

outputting PDF report after long-term measurement of

several days; use MX100001A Viewer report creation

Page 47: Network Master Pro/Flex Release Notesdl.cdn-anritsu.com/en-au/test-measurement/files/Software/Drivers... · 31.07.2020  · USB memory stick formatted to FAT32. 6. Insert the USB

Network Master Pro/Flex Release Notes

47 TAA-1ETNMX0054-47

Version Description

function (CREATE REPORT button) to create reports.

(13410)

[ETH][RoE] At 25 GbE and Frame sizes 8n+4, 8n+5, 8n+6,

and 8n+7 bytes (Example: 68, 69, 70, and 71 bytes) with

Line Rate of 80% or more, sometimes IFG of less than 5

bytes sent; DUT cannot recognize Frames when issue

occurs. (13359)