Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with...

53
©2013 Ventyx, an ABB company | Confidential & Proprietary Network Control: EMS and DMS New Developments and Roadmap Jacek Bujak, Network Manager Forum, October 9 th , 2013

Transcript of Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with...

Page 1: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

©2013 Ventyx, an ABB company | Confidential & Proprietary

Network Control: EMS and DMS New Developments and Roadmap Jacek Bujak, Network Manager Forum, October 9th, 2013

Page 2: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Agenda

©2013 Ventyx, an ABB company | Confidential & Proprietary | 2

Network Manager SCADA/EMS/GMS/DMS

• Vision and Themes

• New Developments & Roadmaps

• Network Manager in the E.ON Project

Page 3: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

The information contained herein:

is for informational purposes only and may not be incorporated into any contract

is intended to outline our general product direction and should not be relied on in making a purchasing decision

is not a commitment, promise, or legal obligation to deliver any material, code or functionality

The development, release, and timing of any features or functionality described for our products remains at our sole discretion.

Safe Harbor

©2013 Ventyx, an ABB company | Confidential & Proprietary | 3

Page 4: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

NM SCADA/EMS/GMS – Vision and Themes

Virtualization Hardware;

Support; Hosting

Incremental Upgrades

Patch Management

Release Fixes

Addressing NERC security requirements

Integration with Cyber Security tools & solutions eg Industrial Defender

1 2 3

Reduced Total Cost of

Ownership Cyber Security

New DTS based on NM-R TS

FAST-DTS - New high-fidelity TS for training and analysis

New features & enhancements in the new DTS

Enhanced Operator Training

Implementing in NM major functions used by NM-R customers

Closing other NM to NM-R gaps

NM-R to NM Upgrades

4

©2013 Ventyx, an ABB company | Confidential & Proprietary | 4

Page 5: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

NM SCADA/EMS/GMS – Vision and Themes – continued

Conformance with modeling and operational rules and requirements in the ENTSO-E zone

Advanced modeling of renewables

Accounting for intermittency of renewable energy in EMS and GMS apps.

5 6 7

ENTSO-E Compliance

Renewable Energy

Quick assessment of power system state

Visualization of power system conditions and application results

Improved Situational Awareness

Enhancements to address common requirements in the Net Apps

New advanced applications eg Voltage Var Contr. for trans.

Network Apps. Enhancements & New Apps.

8

©2013 Ventyx, an ABB company | Confidential & Proprietary | 5

Page 6: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

NM SCADA/EMS/GMS – Vision and Themes – continued

Making EMS/GMS a complete solution

Integration with other packages and products

Processing of phasor data

State Estimation enhanced with PMU data

Advanced WAMS applications

9 10 11

Integrated Solutions with

Ventyx products

Wide-Area Monitoring

State-of-the-art EMS platform and integration capabilities

Independent of underlying SCADA

Advanced EMS Architecture

New GUI with common look-and-feel across NM products

New features to turn data to information for fast decision making

New EMS User Interface

12

©2013 Ventyx, an ABB company | Confidential & Proprietary | 6

Page 7: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

6.0, 6.1 (Q1 2013) 6.2, 6.3 (H2 2013) 2014 & Beyond

Roadmap Overview – SCADA/EMS/GMS

Integration with Industrial Defender

Renewable Energy Modeling - SCADA

EMS/GMS GUI using Windows Pres. Foundation

Industrial standards for integration

Patch Management Offering

Situational Awareness and Optimized Workflows

Display building and Data Maintenance

©2013 Ventyx, an ABB company | Confidential & Proprietary | 7

New GUI for Operation and Data Maintenance

Page 8: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

6.0, 6.1 (Q1 2013) 6.2, 6.3 (H2 2013) 2014 & Beyond

Roadmap Overview – EMS/GMS

ENTSO-E Compliance

NM-R–to-NM Upgrades

Renewable Energy

Integrated Solutions with Ventyx Products

Enhanced Operator Training

©2013 Ventyx, an ABB company | Confidential & Proprietary | 8

New Network Applications

Wide Area Monitoring

Network Application Enhancements

Page 9: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

NM EMS/GMS 6.0

Released Q1 2013

Topology Correction in SE

ENTSO-E Compliance

Net. Apps. Enhancements

Block Control in AGC AGC Enhancements

©2013 Ventyx, an ABB company | Confidential & Proprietary | 9

Color Coding of SA Violations

Switch to Default Network Parameters

Additional Attributes in Equipment Outage Scheduler

Manual Regulation to Regulating Limits

AGC Enhancements New Types of Regulation

Participation Factorss

Monitoring of Non-tracking Units

Absolute and Relative Set-points

Page 10: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

6.0, 6.1 (Q1 2013) 6.2, 6.3 (H2 2013) 2014 & Beyond

Roadmap Overview – EMS/GMS

Enhanced Traning – Port NM-R DTS to Global NM Product

Orthogonal Transformation Algor. in SE

Market Interface to the ERCOT and MISO markets

©2013 Ventyx, an ABB company | Confidential & Proprietary | 10

NM-R-to-NM Upgrades

FAST-DTS – High Fidelity Simulator for Training and Analysis of Trans. Systems

Enhanced Operator Training

Phasor-Enhanced State Estimator

Modeling and Simulation of Hydro Chains

Interface to External Protection Modeling System

Page 11: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

6.0, 6.1 (Q1 2013) 6.2, 6.3 (H2 2013) 2014 & Beyond

Roadmap Overview – EMS/GMS

Loosely Coupled Integration with Genops

Loosely Coupled Integration with Asset Health Monitoring

©2013 Ventyx, an ABB company | Confidential & Proprietary | 11

Integrated Solutions

Loosely Coupled Integration with Nostradamus

Improved Load Forecasting

Extension to Solar Plants

Advanced Management of Wind Farms

Extension to VPPs

Renewable Energy

Page 12: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

6.0, 6.1 (Q1 2013) 6.2, 6.3 (H2 2013) 2014 & Beyond

Roadmap Overview – EMS/GMS

Phasor-Enhanced State Estimator

WAMS Extensions

©2013 Ventyx, an ABB company | Confidential & Proprietary | 12

Wide Area Monitoring

Modeling and Calculations for HVDC – DC Grid

Net. Apps. Enhancements

Phasor- Data Concentrator Integrated with PCU400

Voltage-Var Control - Manual Execution

New Network Applications

Voltage-Var Control - Automatic Execution

Page 13: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Classical Quasi Steady State DTS

Long-term phenomena Short-term phenomena Electromechanical swings Loss of synchronism Simulation of protective devices

V V V V V

Quasi-static phenomena V Long-term phenomena Short-term phenomena Electromechanical swings Loss of synchronism Simulation of protective devices

V Quasi-static phenomena V

FAST-DTS

Needed for a correct representation of power

system behaviour!

FAST DTS - new Dispatcher Training Simulator

©2013 Ventyx, an ABB company | Confidential & Proprietary | 13

Page 14: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Simple

Freq

uent

Se

ldom

Blackout / Blackstart

New Procedure

Prot. Failure

Daily Switching

Splitting+

Resynch

Complex

Local

Global

Extreme Weather

Multiple Failures

Volt. Collapse

Freq. Collapse Global /

Local

Global /InterTSO

Local/Global/InterTSO

FAST DTS – from simple to complex scenarios

©2013 Ventyx, an ABB company | Confidential & Proprietary | 14

Page 15: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

New Dispatcher Training Simulator

Real-time SCADA/EMS Environment Real-time

start solution

UDW recorded data points

OTS Training Environment

Engineering and Maintenance Environment Power

system model

Development Environment

Programs, calculations, scripts…

Conditional Events

Interface to CAPE - Protection. Modeling System

Hydro-Chain Modeling

©2013 Ventyx, an ABB company | Confidential & Proprietary | 15

Page 16: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Transmission Network Applications and VVC

Telemetry Snapshot (SNP) Status and Analog Retrieval (SAR) Network Model Builder (NMB) Bad Topology Detection (BTD) Bus Scheduler (BSK) State Estimator (SE) SE Hourly Save Cases (SES) Optimal Power Flow (OPF) Security Analysis (SA) Security Constrained Dispatch

(SCD) Voltage Stability Analysis(VSA) Network Sensitivities (NS) Network Parameter Update (NPU) Reactive Power Reserve (RPR) Interlock Power Flow and Security

Analysis (ISR, INMB, IDPF, ISA) Pattern

Data

Analog Measurements

Tuning Parameters Status

Measurements

ICCP Data

SAR

SES

OPF

SA

SCD

NS

NPU

RPR

ISR INMB IDPF ISA

Operator Entries

Maintenance Scheduling

Data

SNP

NMB

BTD

BSK

SE

VSA

VVC

VVC (Voltage-Var Control for Transmission) will find optimal Voltage-VAr settings , and schedule power system voltage (reactive) controls to achieve a user-selected optimization objective while ensuring that the system operating constraints are not violated.

©2013 Ventyx, an ABB company | Confidential & Proprietary | 16

Page 17: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Production Scheduling Overview with Genops & Nost

Optimal scheduling of generation resources and interchange transactions to minimize total operating costs

The results of these programs have a significant impact on the cost of electricity production and overall operational efficiency

Network Sensitivities

Economic Dispatch

Automatic Generation

Control

Utility Data Warehouse INTERCHANGE SCHEDULING

Dispatcher Power Flow

SHORT TERM LOAD FORECASTING

UNIT COMMITMENT

Genops

Nostradamus

©2013 Ventyx, an ABB company | Confidential & Proprietary | 17

Page 18: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Management of Hydro Resources • Real-Time Monitoring & Control of hydroelectric power plants and

associated water resources

• Optimal Scheduling of all generation resources, subject to operational and environmental constraints

• Minimization of the overall operational cost

• Capability to model cascaded hydro systems and topology

• Handling of complex hydro characteristics and constraints

Wind (and Solar) Generation • Centralized Management of Wind Farms

• Enhancements in the EMS and GMS Applications to improve the modeling, monitoring and control of wind farms and account for intermittency of wind power

• Simulating wind related outages and power variations of a plant, a region/sub-region and a power grid

• Integration of Wind Power Forecast

• Wind Power Visualization on Operator’s displays

Renewables – with Wind and Solar Energy Mgmt.

©2013 Ventyx, an ABB company | Confidential & Proprietary | 18

Page 19: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

NM DMS - Vision and Themes

Efficient operation of network

Automated restoration

Operate closer to limits

Reduce outage time

Increased cyber security

1 2 3

Smart Grid Improve Reliability

Eliminate reliance on paper maps and manual switch procedures

Reduce operational time and errors

Improve Workflows

Provide integrated solutions

More efficient data engineering

Reduced Total Cost of

Ownership

4

©2013 Ventyx, an ABB company | Confidential & Proprietary | 19

Page 20: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

7.2 (Q1 2014) 7.3 (H2 2014) 8.0 (H1 2015)

DMS Roadmap Overview

Improve Operator Workflows

Reduce Total Cost of Ownership

Smart Grid

Improve Reliability

©2013 Ventyx, an ABB company | Confidential & Proprietary | 20

Page 21: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

NM DMS 7.1

Released H1 2013

Common Alarm and Event Lists

DMS in WPF

Situational Awareness

Optimized Workflows

Coordinated views Advanced Search Tools

©2013 Ventyx, an ABB company | Confidential & Proprietary | 21

Operator Actions from DMS DMS Worldmap in WPF

Background Maps

OMI Integration

Display Converter

Workflow Orientation

Page 22: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

PSE is a major R&D effort with a main goal to remake the entire HMI for Network Manager (SCADA/EMS/DMS product lines) Cutting edge user experience and support situational awareness PSE is an integration platform for various functions and products needed in the

control room Everything from operations to maintenance will be handled by one application

NM DMS 7.1 - with Power System Explorer (PSE)

©2013 Ventyx, an ABB company | Confidential & Proprietary | 22

Page 23: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Demand Response Capabilities presented in the DMS network

FocalPoint KPI visualization based on selections in DMS, EMS or SCADA screens

Integration between Ventyx Products

©2013 Ventyx, an ABB company | Confidential & Proprietary | 23

Page 24: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

NM DMS 7.2

Targeted Q1 2014

Improve Situational Awareness

Smart Grid

Improve Workflow

Improve Reliability

Retrieve fault measurements via SCADA

AMI Pinging AMI Restoration Verification

©2013 Ventyx, an ABB company | Confidential & Proprietary | 24

Retrieve Dynamic Transformer Limits by SCADA

Load Forecasting Demand Response

Assign Crew to Fault Location

Distributed Energy Resources

Work Tag Notifications

Exchange Outage Data with Field Crews

Switch Order Recording

Page 25: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Smart Grid

SCADA Fault Measurements

Automatically retrieve fault measurements via SCADA Enables FLISR to locate the fault automatically

Benefits

When coupled with FLISR, allows isolation and restoration within momentary outage time

Reduces outage time

Reduces equipment operations by removing the need to manual test to locate the fault

©2013 Ventyx, an ABB company | Confidential & Proprietary | 25

Page 26: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Smart Grid

SCADA Transformer Limits Retrieves dynamic transformer limits from substation Limits reflect local real-time conditions

Benefits

More accurate overload alarming and capacity margin calculation

©2013 Ventyx, an ABB company | Confidential & Proprietary | 26

Page 27: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Smart Grid

Load Forecasting Load forecast at a service transformer level Accounts for AMI and weather input

Benefits

Improved estimation of non telemetered loading when combined with State Estimation

Prediction of future overloads allows mitigation plans to avoid outages using VVO, DRMS, and line unloading

©2013 Ventyx, an ABB company | Confidential & Proprietary | 27

Page 28: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Smart Grid

DER Forecasting Forecast of distributed energy resource generation Wind, solar and thermal

Benefits

Accurate estimation of distribution network loading when combined with State Estimation

Prediction of future overloads allows mitigation plans to avoid outages using VVO, DRMS, and line unloading

Prediction of power and voltage problems during loss of generation using contingency analysis [available in NM DMS 8.0]

©2013 Ventyx, an ABB company | Confidential & Proprietary | 28

Page 29: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Smart Grid

Demand Response Reduction of overloads with demand response targeted to customers downstream of overload

Benefits

Mitigate overloads to avoid power outages and equipment damage

Reduce peak demand to offset generation and distribution investment

©2013 Ventyx, an ABB company | Confidential & Proprietary | 29

Page 30: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Improve Operator Workflow

Improved Operator Situational Awareness

Satellite map views, camera view windows, and ability to move windows to different displays

Benefits

Improve operators situational awareness with multiple views showing electrical network, streets maps, and satellite view

Improve operator efficiency with modern graphical controls and improved workflows

Reduce operator training time

©2013 Ventyx, an ABB company | Confidential & Proprietary | 30

Page 31: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Improve Workflow

Assign Crew to Fault Location

Assign crew to fault location or switchable device

Benefits

Assign crew to fault locations to restore outage faster

©2013 Ventyx, an ABB company | Confidential & Proprietary | 31

Page 32: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Improve Workflow

Switch Order Recording Create switch orders by recording switching operations

Benefits

Reduce time to create switch order by allowing operations to be recorded directly in a switch order

©2013 Ventyx, an ABB company | Confidential & Proprietary | 32

Page 33: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Improve Reliability

AMI Pinging Call taker and Operator pinging of AMI meter to determine power on status

Benefits

Reduce callouts for customer level outages

Reduce outage duration by allowing operator to verify the extent of a predicted outage

©2013 Ventyx, an ABB company | Confidential & Proprietary | 33

Page 34: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Improve Reliability

AMI Restoration Verification

Customer power on is automatically verified through AMI immediately following restoration switching

Benefits

Crew can be notified there is additional outage work before leaving the area

Customers are not notified of power restoration when their power is still out

©2013 Ventyx, an ABB company | Confidential & Proprietary | 34

Page 35: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Improve Reliability

Work Tag Notifications Automatically notify field crews when work tags are placed or removed

Benefits

Improve safety and reduce work duration by notifying crews when tags are placed ore removed on equipment in their work vicinity

©2013 Ventyx, an ABB company | Confidential & Proprietary | 35

Page 36: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

NM DMS 7.3

In Planning H2 2014

Enhanced Outage Management Workflows

Smart Grid

Improve Workflow

State Estimation Feeder Reconfiguration

©2013 Ventyx, an ABB company | Confidential & Proprietary | 36

Page 37: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Smart Grid

State Estimation Estimate loading on distribution network that matches

SCADA measurements, load and generation profiles and voltage measurements

Benefits

Confidence in operational state of the distribution network

Allows operation closer to capacity margin

©2013 Ventyx, an ABB company | Confidential & Proprietary | 37

Page 38: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Smart Grid

Feeder Reconfiguration Reduce losses and balance parallel transformers by moving normal open feeder tie points

Benefits

Most efficient feeder topology

Utilize more feeder capacity

©2013 Ventyx, an ABB company | Confidential & Proprietary | 38

Page 39: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Improve OMI Workflows

Improve Workflow Streamline work flow e.g. reducing OMI windows and key clicks

Benefits

More efficient processing of outages

©2013 Ventyx, an ABB company | Confidential & Proprietary | 39

Page 40: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

NM DMS 8.0

In Planning H1 2015 Smart Grid

Improve Operator Workflow

Contingency Analysis

©2013 Ventyx, an ABB company | Confidential & Proprietary | 40

Earth Fault Localization Enhanced Fault Location

Common DMS/SCADA HMI Common DMS/SCADA Data Engineering

Enhanced Power System Modeling

Dispatcher Training Simulator

Improve Reliability

Page 41: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Smart Grid

Contingency Analysis Evaluate network security for n-1 component failure

Benefits

Increase reliability by identifying component failures that cause unacceptable operating conditions

Plan for mitigation before the event happens

©2013 Ventyx, an ABB company | Confidential & Proprietary | 41

Page 42: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Smart Grid

Earth Fault Localization Graphical tool to help operator isolate ungrounded earth faults

Benefits

Increase safety by allowing operator to isolate earth fault in ungrounded or compensated network where no fault current flows on first fault

Prevent outages where second fault would clear line

©2013 Ventyx, an ABB company | Confidential & Proprietary | 42

Page 43: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Smart Grid

Enhanced Fault Location Locate fault areas based only on SCADA fault indicator status

Benefits

Reduce fault isolation and restoration time

Reduce SAIFI by isolating and restoring customers within the momentary switching time

©2013 Ventyx, an ABB company | Confidential & Proprietary | 43

Page 44: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Improve Operator Workflow

Common DMS/SCADA HMI

Common display for world map views and SCADA picture file views with SCADA and manual operations from either view

Common alarm list and line coloring

Benefits

Increase operators situational awareness with common alarms and seamless display interaction

Reduce training for DMS system with SCADA, DMS, and OMS capability

©2013 Ventyx, an ABB company | Confidential & Proprietary | 44

Page 45: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Improve Operator Workflow

Common DMS/SCADA Data Engineering

One HMI interface to maintain DMS and SCADA data

Benefits

Reduce the number of screens and systems needed to set-up and maintain the DMS system

©2013 Ventyx, an ABB company | Confidential & Proprietary | 45

Page 46: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Improve Reliability

Dispatcher Training Simulator

Training simulator driven by independent field database model to realistically simulator power flows, voltages, and outage calls experienced by the SCADA, DMS, and OMS operators

Benefits

Improve operator response under complex operating scenarios

©2013 Ventyx, an ABB company | Confidential & Proprietary | 46

Page 47: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

2015 and Beyond

2015 and Beyond Smart Grid

Improve Operator Workflow

DER Control in VVO

©2013 Ventyx, an ABB company | Confidential & Proprietary | 47

Predictive Load Flow

Predictive Contingency

Pre-switch Load Flow

On-line Protection Coordination

CIM Compliant Interfaces

Reduce TCO

Improve Reliability

Enhanced Tagging Combined Subtransmission and Distribution Processing

Page 48: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Network Manager SCADA/EMS/DMS, E.ON Sweden

Customer need Integration of wind and renewables in sub-transmission and distribution network Predict and prevent instability issues Avoid network congestions

ABB response Network Manager Smart Grid Control Center for the mid- and low voltage network Renewable generation forecast using Nostradamus application Look ahead network optimization considering forecast, schedules and dynamic line rating Demand response functionality integrating consumers with Ventyx DRMS application Situational awareness and presentation using Ventyx BI tool Focal Point

Customer benefits Minimized grid losses in mid- and low voltage network Preventive, instead of reactive, network operation Increased awareness of future contingencies and bottlenecks Reduced operator stress

Customer: E.ON, Sweden System operation in 2014

©2013 Ventyx, an ABB company | Confidential & Proprietary | 48

Page 49: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Solution Overview – Integration Landscape

©2013 Ventyx, an ABB company | Confidential & Proprietary | 49

Scada

Weather

EMS

Nostradamus

DRMS

Focal Point

Scada Measurements

Network Topology

Substation Weights

Load Reduction Requests

Load Reduction Recommendations

Historical Weather Data Weather Forecast

Load and Renewable Generation Forecasts

Predicted Events

Meter Reads

Page 50: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

VVC Calculation and Optimization

The VVC execution provides optimal Voltage-VAr settings, using available reactive power controls.

©2013 Ventyx, an ABB company | Confidential & Proprietary | 50

Page 51: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

VVC Objectives

The VVC function provides optimal Voltage-VAr settings, using available reactive power controls. VVC acts in real-time and look-ahead modes. VVC will be used in the E.ON project to address several operational scenarios. The main objectives are to:

Optimize the voltage and reactive power in the system and predict the voltage profiles for the next six hours

Predict possible subscriptions violations for the next six hours and present a list of MW recommended actions in order to prevent it

Predict possible line congestions for the next 6 hours and present a list of MW recommended actions in order to prevent it

Provide a complete set of output to allow the operator to evaluate the actual and forecasted state of the network. The output will include a solution summary, pre and post optimization bus voltage, branch flow violation and the bus voltage profile.

©2013 Ventyx, an ABB company | Confidential & Proprietary | 51

Page 52: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

E.ON SGCC Architecture

©2013 Ventyx, an ABB company | Confidential & Proprietary | 52

Page 53: Network Control: EMS and DMS New Developments and …...NERC security requirements Integration with Cyber Security tools & solutions eg Industrial Defender . 1 . 2 3 . Reduced Total

Thank You