Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 3 of 50
Log MessagesNetvisor One
Version 5.1.2
February 2020
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 2 of 50
Table of contents
Netvisor One Log Messages 5.1.2 ................................................................................................... 3Legal Notice ............................................................................................................................. 4Audit Log Messages .................................................................................................................. 5Event Log Messages .................................................................................................................. 7System Log Messages .............................................................................................................. 33
About Pluribus Networks ............................................................................................................. 50
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 4 of 50
Legal Notice
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TOCHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THISMANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND,EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANYPRODUCTS.
THE SOFTWARE LICENSE LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH INTHE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BYTHIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY,CONTACT YOUR PLURIBUS NETWORKS REPRESENTATIVE FOR A COPY.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE AREPROVIDED “AS IS” WITH ALL FAULTS. PLURIBUS NETWORKS DISCLAIMS ALL WARRANTIES, EXPRESS ORIMPLIED, INCLUDING WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULARPURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADEPRACTICE.
IN NO EVENT SHALL PLURIBUS NETWORKS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, ORINCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA,ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF PLURIBUS NETWORKS HAS BEENADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Anyexamples, command display output, and figures included in the document are shown for illustrativepurposes only. Any use of actual IP addresses in illustrative content is unintentional and coincidental.
© 2020 PLURIBUS NETWORKS, INC. ALL RIGHTS RESERVED.
Version 5.1.2 February 2020
Version 5.1.1 December 2019
Version 5.1.0 September 2019
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 5 of 50
Audit Log Messages
Identifier Message Code Description
it_happened wow, ithappened!
90000 Something happened.
audit_drop
Unable todeliver auditlog so auditlogs dropped
10001Audit logs could not bedelivered.
audit_repeats Lastnumber message(s) repeatednumber time(s)
20004 Compress repeatedmessages.
mon_command_start
starting commandcmd-name
30002 Monitor startingcommand.
mon_command_finish
finished commandcmd-name resultresult
30003 Command run by nvOSmonitoring
audit_drop lost drop-idmsg(s)
10002 Unable to deliver auditlog(s) to nvlogd so auditlogs dropped.
user_command Command cmd-name resultresult
11001 Administrator has run acommand.
command_err Command cmd-name failederror
11098 Command failed insuch a way that theresults cannot betransmitted back to theclient.
login login 11099 User logged in.
logout logout 11100 User logged out.
xact_command Transactioncommand cmd-name resultresult
11101 Command run as aresult of a transactionon a different node.
internal_command Internal commandcmd-name resultresult
11102 Command run bynvOSd.
login_failed login failed:error
11103 User unable to log intothe switch.
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 6 of 50
tacacs_sess_deny %[tacacs_msg]s 11410 TACACS+ server deniedsession.
tacacs_sess_ok %[tacacs_msg]s 11411 TACACS+ serverauthorized session.
tacacs_cli_cmd_deny
cmd=%[cmd]s %[tacacs_msg]s
11412 TACACS+ server deniedcommand.
tacacs_cli_cmd_ok
cmd=%[cmd]s %[tacacs_msg]s
11413 TACACS+ serverallowed command
shell_command Command \"%[cmd]s\" status %[status]s
33000 shell command
vtysh_command Command \"%[cmd]s\" result=%[result]d
33001 vtysh command
tacacs_shell_cmd_deny
cmd=%[cmd]s %[tacacs_msg]s
33002 TACACS+ server deniedshell command
tacacs_shell_cmd_ok
cmd=%[cmd]s %[tacacs_msg]s
33003 TACACS+ serverauthorized shellcommand
tacacs_vtysh_cmd_deny
cmd=%[cmd]s %[tacacs_msg]s
33004 TACACS+ server deniedvtysh command
tacacs_vtysh_cmd_ok
cmd=%[cmd]s %[tacacs_msg]s
33005 TACACS+ serverauthorized vtyshcommand
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 7 of 50
Event Log Messages
Identifier Message Code Description Type VNET
event_repeats
Last %[msgs]dmessagesrepeated %time[times]dtime(s)
20003Compressrepeatedmessage
System N/A
openstack_error
Openstackerror: %[name]s: %[func]s - %[err]s
31009Openstackerrors on thenvOS CLI
OpenStack
openstack_informational
Openstackinfo: %[name]s: %[func]s -%[info]s
31010Openstackinformationalmessages
OpenStack
event_dropLost drops-id msgs
10000
Unable to deliverevent(s) tonvlogd so eventsdropped.
System N/A
ipsla_unreachable
%[name]s: %[msg]s - %[route_info]s
31013 IPSLA: linktrackip is unreachable System
ipsla_reachable
%[name]s: %[msg]s - %[route_info]s
31014 IPSLA: linktrackip is reachable System
port_up Up 11002 A port is up. Port by-port
port_down Down 11003 A port is down. Port by-port
conn_new
src-macmac src-ip ipsrc-portport-id dst-mac mac dst-ip ip dst-port port-id new tcpconnection
11004 New TCPconnection TCP by-vxlan by-vlan
by-port
conn_done
src-macmac src-ip ipsrc-portport-id dst-mac mac dst-ip ip dst-port port-
11005 TCP Connectionfinished. TCP
by-vxlan by-vlanby-port
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 8 of 50
id bytes-sentbytes bytes-receivedbytes new tcpconnection
ptp_time_adjust
Adjustingtime byoffset
11010PTP slaveadjusting switchclock.
PTP
ptp_frequency_adjust
Adjustingclockfrequencyadjusting
11011PTP slaveadjusting switchfrequency
PTP
mac_ip_addMAC/IPaddress addedmac=mac ip=I
11022
Detected a newMAC addressand IP addresson a port.
Port by-vxlan by-vlanby-port
mac_ip_changeIP addresschangemac=mac ip=ip
11023
IP Address for aMAC addresschanged on aport.
Port by-vxlan by-vlanby-port
stp_port_online
STP PORTOnline: port-id
11024
Port added forSTPconsideration inresponse to portup event.
STP
stp_port_offline
STP PORTOnline: port-id
11025
Port deleted forSTPconsideration inresponse to portdown event.
STP
stp_port_state
port changedstp state 11026
The portchanged the STPstate.
Port
stp_port_fastSTP PortFast: port-id 11027
The given STPport will operatein port fastmode.
STP
stp_destroy
STPDestroyingSpanningTree: vlan-id
11032
STP destroying aspanning treethat wasoperating for aVLAN.
STP
stp_blacklist_recv
Received STPBPDU onblacklistedport:port=port-id vlan=vlan-id
11033Received an STPBPDU on ablacklisted port.
STP
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 9 of 50
stp_invalid_bpdu
STP BPDUinvalid:port=port-id vlan=vlan-idreason=reason
11034 Received STPBPDU is invalid. STP
stp_processing_bpdu
STPProcessing:port=port-id vlan=vlan-idproto=protolen=length
11035Processing validSTP or PVSTBPDU.
STP
stp-unknown_bpdu
STP UnknownBPDU:port=port-id vlan=vlan-id bpdu-type=type-id
11036Receivedunknown BPDUtype.
STP
stp_maximum_age
STP BPDU hasreachedmaximum age:port=port-id vlan=vlan-id
11037BPDU hasreachedmaximum age.
STP
stp_root
STP Port isRoot:port=port-id vlan=vlan-id
11038
The port hasbeen selected asthe root ofspanning tree.
STP
stp_designated
STP Port isDesignated:port=port-id vlan=vlan-id
11039
The port hasbeen becomethe designatedport.
STP
stp_sending_bpdu
STP SendingBPDU:bpdu=bpduport=port-id vlan=vlan-id
11040The port hasbecomedesignated port.
STP
stp_trunk_update
STP TrunkUpdate:trunk=trunk-id port=port-id
11042
The loading andapplication ofSTPconfigurationfailed.
STP
stp_doneSTP STG Done:vlan=vlan-id 11043
STP statemachine for thespecified VLANis beingshutdown.
STP
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 10 of 50
stp_create
STP STGCreate:vlan=vlan-id mac=mac
11044
STP is creating aSTP statemachine for theVLAN.
STP
igmp_add_router
IGMP AddingRouter toGroup:group=group
11056
IGMP snoopingadding router tothe specifiedgroup.
IGMP
igmp_switch_multicast_port_add
IGMP Port AddFailed:port=port-id group=group-idvlan=vlan-id
11057IGMP snoopingunable to addport to group.
IGMP
igmp_switch_multicast_port_remove
IGMP PortRemoveFailed:port=port-id group=group-idvlan=vlan-id
11058
IGMP snoopingunable toremove portfrom group.
IGMP
igmp_host_add
IGMP AddedHost toGroup:port=port-id vlan=vlan-idgroup=group-idserver=servers
11059IGMP snoopingadded host togroup.
IGMP
igmp_host_remove
IGMP RemovedHost fromGroup:port=port-id vlan=vlan-idgroup=group-idserver=servers
11060 IGMP removedhost from group. IGMP
igmp_v1_report
IGMP Does NotProcess V1Report:port=port-id vlan=vlan-id
11061IGMP does notprocess version1 IGMP packets.
IGMP
igmp_v2
IGMPProcessing V2Packet:port=port-
11062
IGMP snoopingprocessed aIGMP v2 reportor leave
IGMP
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 11 of 50
id vlan=vlan-idgroup=group-idserver=servers type=type
messages.
igmp_v3_record
IGMPProcessing V3Record:port=port-id vlan=vlan-idgroup=group-idserver=servers type=type
11063IGMP snoopingprocessing V3record.
IGMP
igmp_v3_report
IGMPProcessing V3Report:port=port-id vlan=vlan-idserver=servers numrec=type
11064IGMP snoopingprocessing V3Report
IGMP
igmp_add_update_globalmc
IGMPAdd/Updateglobalmc:port=port-id vlan=vlan-id
11065
IGMP snoopingadding orupdatingglobalmc for portand VLAN.
IGMP
igmp_remove_globalmc
IGMP Removingglobalmc:port=port-id vlan=vlan-id
11066
IGMP snoopingremovingglobalmc for portand VLAN.
IGMP
igmp_drop_packet
IGMP droppingpacket:port=port-id vlan=vlan-id
reason=reason
11067IGMP snoopingis dropping apacket.
IGMP
igmp_ignore_packet
IGMP Ignoringpacket:port=port-id vlan=vlan-id igmp-type=type
11068IGMP is ignoringreceived IGMPpacket.
IGMP
igmp_group_add
IGMP AddingGroup:vlan=vlan-idgroup=group
11069
IGMP snoopingadded a group tothe switchhardware.
IGMP
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 12 of 50
igmp_group_remove
IGMP RemovingGroup:vlan=vlan-idgroup=group
11070
IGMP snoopingremoved a groupfrom the switchhardware.
IGMP
lldp_agent_create
LLDP AgentCreate: mac=mac group=I
11078
Creating LLDPagent forspecified groupon specifiedswitch.
LLDP
lldp_port_enable
LLDP PortEnable:port=port-id
11082
Specified porthas beenenabled forLLDP operation.
LLDP
lldp_port_disable
LLDP PortDisable:port=port-id
11083
Specified porthas beenremoved fromLLDP operation.
LLDP
lldp_pdu_drop LLDP PDU Drop 11084
LLDP PDUreceived on porthas beendropped.
LLDP
llp_pdu_invalid
LLDP PDUInvalid:port=port-idreason=reason
11085LLDP PDUreceived on portwas invalid.
LLDP
lldp_processing_pdu
LLDPProcessing:port=port-idvlan=vlan-id
11086LLDP isprocessing areceived PDU
LLDP
lldp_tlv_construct_failed
LLDP TLVConstructFailed:
port=port-idreason=reason
11087
LLDP cannotconstruct aproper TLV forthe PDU.
LLDP
evb_process_tlv
EVBProcessingEVB TLV:port=port-id
11088EVB TLVprocessing on aspecific port.
EVB
evb_tlv_dropEVB TLV Drop:port=port-idreason=reason
11091A received EVBTLV wasdropped.
EVB
ecp_send_packet_failed
ECP Send PDUFailed:port=port-idreason=reason
11092Unable to sendEVB PDU onspecified port.
ECP
ecp_send_packet
ECP Send PDU:port=port-idtype=type
11093 Sent ECP PDU onspecified port. ECP
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 13 of 50
ecp_pdu_dropECP Drop PDU:port=port-idtype=type
11094
Received ECPPDU wasdropped onspecified port.
ECP
evb_bandwidth_limit_failed
EVB BandwidthLimitFailure:port=port-idvlan=vlan-idreason=reason
11096
Unable toenforcerequestedbandwidth limit.
EVB
evb_bandwidth_limit
EVB BandwidthLimit:port=port-idvlan=vlan-idflow=flowbw=bw
11097Enforcingrequestedbandwidth limit.
EVB
stp_trunk_port
STP TrunkPort:port=port-idvlan=vlan-idtree=tree-idtrunk=trunkcontrol=control-id
11104
Specified port ispart of a trunkfor this SpanningTree.
STP
stp_trunk_remove
STP TrunkRemove:trunk=trunkvlan=vlan-idtree=tree-id
11105
Specified port isbeing removedfrom STP trunkconfiguration.
STP
adj_trunk_create
ADJ CreateAuto Trunk:trunk=trunkport=port-id
11106Created a trunkin adjacencycode.
Port
adj_trunk_port_add
ADJ TrunkPort Add:trunk=trunkport=port-id
11107Added thespecified port tothe trunk.
Port
storage_device_remove
Storagedevicedevice removed.
11108Storage deviceremoved fromswitch.
Storage
storage_device_added
Storagedevicedevice added.
11109Storage deviceadded fromswitch.
Storage
storage_pool_status_notok
Storage poolpoolname instatus stateavailabledisk
11110 Storage poolstatus is not ok. Storage
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 14 of 50
space=space
igmp_add_host_failed
IGMP Add HostFailed: vlan=%[vlan]dgroup=%[group]shost=%[host]s
11112 IGMP snoopingadd host failed. IGMP
igmp_add_sources_failed
IGMP SourcesAdd Failed:vlan=%[vlan]dgroup=%[group]shost=%[host]s
11113
IGMP snoopingsources addfailed for a givenhost
IGMP
igmp_remove_host_failed
IGMP RemoveHost Failed:vlan=%[vlan]dgroup=%[group]shost=%[host]s
11114IGMP snoopingremove hostfailed.
IGMP
igmp_remove_sources_failed
IGMP SourcesRemoveFailed: vlan=%[vlan]dgroup=%[group]shost=%[host]s
11115IGMP snoopingremoval ofsources failed
IGMP
stp_hello_time
STP HelloTime Change:vlan=%[vlan]dtime=%[time]d
11116STP hello timechange for STPinstance
STP
stp_max_Age
STP Max AgeChange: vlan=%[vlan]dtime=%[time]d
11117Max age timechange for STPinstance
STP
stp_forward_delay
STPForwardingDelay Change:vlan=%[vlan]dtime=%[time]d
11118Forwarding delaychanged for STPinstance.
STP
stp_hello_timer_expired
STP HelloTimerExpired:vlan=%[vlan]d
11119Hello timerexpired for STPinstance
STP
stp_bridge_id_change
STP Bridge IDChange: vlan=%[vlan]d id=%[id]llx
11120 New bridge IDfor STP instance STP
stp_tcn_bpdu
STP TCN bpduprocessing:vlan=%[vlan]dport=%[port]d
11121Processing TCNBPDU for STPinstance
STP
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 15 of 50
stp_configuration_bpdu
STPConfigurationBPDU: vlan=%[vlan]d port=%[port]disroot=%[isroot]d
11122
ProcessingconfigurationBPDU forinstance
STP
stp_supersedes_port_info
STPSupersedesPort Info:vlan=%[vlan]dport=%[port]d
11123
Config BPDUindicatespossible changein STP topology
STP
stp_root_port_select
STP Root PortSelect: vlan=%[vlan]dport=%[port]d
11124Root portselection for STPtopology
STP
tacacs_invalid_server
Invalidserver=server(s): error
11126
Server namecanʼt be resolvedvia DNS or aninvalid IPaddress wasused.
TACACS
tacacs_connect_error
server=server(s): unableto connect:reason
11127Unable toconnect toTACACS+ server.
TACACS
tacacs_shell_author_req_failed
server=server(s)user=user(s):Shellauthorizationrequestfailed:reason
11128
Shellauthorizationrequest toTACACS+ serverfailed
TACACS
tacacs_unknown_role
server=server(s)user=user(s)role=role(s):unknown role
11129
Unrecognizedrole in TACACS +shellauthorizationresponse.
TACACS
tacacs_unknown_attr
server=server(s)user=user(s)req=req(s)attr=attribute(s): unknownmandatoryattribute
11130Received anunrecognizedattribute.
TACACS
tacacs_user_not_author
server=server(s)user=user(s)req=req(s)status=status
11131
Authorizationrequestreturned badstatus for a user.
TACACS
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 16 of 50
: user notauthorized
tacacs_ignore_attr
server=server(s)user=user(s)req=req(s)attr=attribute(s):ignoringunknownoptionalattribute
11132Ignoring anoptionalattribute.
TACACS
tacacs_cmd_author_fail
server=server(s)user=user(s):authorizationfailed:reason(s)
11133Failed toauthorize acommand.
TACACS
tacacs_authen_start_failed
server=server(s)user=user(s):authentication startedfailed:result(s)
11134 Authenticationstart failed. TACACS
tacacs_authen_failed
server=server(s)user=user(s)status=statusserver_msg=msg:authentication failed.
11135 Authenticationfailed. TACACS
tacacs_acct_failed
server=server(s)req=req(s)user=user(s):accountingfailed:result(s)
11136 Accountingrequest failed. TACACS
tacacs_acct_bad_status
server=server(s)req=req(s)user=user(s)status=status:server_msg=msg result(s)
11137
Bad statusreceived inresponse toaccountingrequest.
TACACS
igmp_group_port_remove
IGMP PortRemove: vlan=%[vlan]dgroup=%
11138Switch port isremoved fromIGMP group
LACP
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 17 of 50
[group]sport=%[port]d
igmp_group_port_add
IGMP PortAdd: vlan=%[vlan]dgroup=%[group]sport=%[port]d
11139Switch port isadded to IGMPgroup
LACP
lacp_port_enable
LACP PortEnable: port=%[port]d
11150Port is enabledfor LACP PDUprocessing
LACP
lacp_port_disable
LACP PortDisable:port=%[port]d
11151Port ProcessingPDU is disabledon the port.
LACP
lacp_disable LACP Disabled 11152 LACP feature isdisabled. LACP
lacp_enable LACP Enabled 11153 LACP feature isenabled. LACP
lacp_port_mode
LACP PortMode: port=%[port]d mode=%[mode]s
11154
LACP Port modeis set to OFF orPASSIVE orActive
LACP
lacp_port_upLACP Port Up:port=%[port]d 11155 LACP Port is up LACP
lacp_trunk_port_add
LACP TrunkAdd Port:trunk=%[trunk]dport=%[port]d
11156 Adding Port toLACP trunk LACP
lacp_trunk_port_remove
LACP TrunkRemove Port:trunk=%[trunk]dport=%[port]d
11157 Remove portfrom LACP trunk LACP
lacp_port_expired
LACP PortExpired:port=%[port]d
11158 LACP port statehas expired LACP
lacp_port_defaulted
LACP PortDefaulted:port=%[port]d
11159LACP Port stateis now defaultstate
LACP
lacp_port_no_sync
LACP Port NoSync: port=%[port]d
11160 LACP port stateis not SYNC LACP
lacp_port_assert_ntt
LACP PortAssert NTT:port=%[port]d
11161 LACP hasasserted NTT LACP
lacp_port_collecting
LACP PortCollecting: 11162 LACP Port State
enable/disable LACP
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 18 of 50
port=%[port]dstate=%[state]s
collecting
lacp_port_distributing
LACP PortDistributing:port=%[port]dstate=%[state]s
11163
LAPCP PortStateenable/disabledistributing
LACP
lacp_port_select
LACP PortSelect: port=%[port]d lag=%[lag]s
11164LACP Port isselected foraggregation
LACP
lacp_port_unselect
LACP Port NotSelected:port=%[port]d
11165LACP Port isremoved fromaggregation.
LACP
lacp_port_mux_state
LACP Port MuxState: port=%[port]d mux=%[mux]s
11166 LACP port is setto this mux state LACP
lacp_pduLACP PDU:port=%[port]dtype=%[type]s
11167 LACP PDU isreceived on port LACP
lacp_trunk_not_found
LACP NoMatchingTrunk: trunk=%[trunk]d
11168
No matchingtrunk found forLACP whileprocessing LACPstate
LACP
lacp_aggregator_addref
LACP LAG Add:lag=%[lag]scur=%[cur]dnew=%[new]dports=%[ports]d
11169
A port is addedto an LACP LAGforconsideration.
LACP
lacp_aggregator_delref
LACP LAGDelete: lag=%[lag]s cur=%[cur]d new=%[new]d ports=%[ports]d
11170
A port isremoved fromLACP LAGconsideration
LACP
lacp_pdu_fail
LACP PDUFailure:port=%[port]dfailure=%[failure]s
11171LACP PDIprocessingfailure
LACP
lacp_port_state
LACP PortState: port=%[port]d info=%[info]sstate=%[state]s
11172 LACP port state LACP
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 19 of 50
lacp_,marker_pdu
LACP XmitMaker PDU:port=%[port]drq=%[rq]dsysaddr=%[sysaddr]sxid=%[xid]d
11174LACP sendingMarker PDU onport
LACP
lacp_xmit_pduLACP XmitPDU: port=%[port]d
11175 Send LACP PDUon port LACP
lacp_port_down
LACP PortDown: port=%[port]d
11176 LACP port isdown LACP
tacacs_bad_scope
server=%[server]suser=%[user]sscope=%[scope]s:unrecognizedscope. scopemust beeither\"local\" or\"fabric\"
11177
TACACS serverreturnedsomething thatis not a scope
TACACS
tacacs_scope_mismatch
server=%[server]suser=%[user]sscope=%[scope]s:server withlocal scopecan onlyassign scopeof local toits users
11178
TACACS serverreturned fabricscope but serveris local
TACACS
storage_device_size_changed
Storagedevice %[device]ssize changedfrom %[old]ldto %[new]ld
11179 Storage devicesize changed. Storage
stp_forwarding_delay_timer
STP ForwardDelay Timer:port=%[port]dvlan=%[vlan]d
11182StartingForwarding DelayTimer on switch
STP
stp_forwarding_delay_timer_expired
STP ForwardDelay TimerExpired:port=%[port]dvlan=%[vlan]d
11183
StartingForwarding Delaytimer expired onswitch
STP
stp_vlan_port_add
STP VLAN portadd: port=% 11184 Add port to
spanning tree STP
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 20 of 50
[port]d vlan=%[vlan]d for vlan
stp_vlan_port_remove
STP VLAN portremove: port=%[port]dvlan=%[vlan]d
11185Remove portfrom spanningtree for VLAN
STP
port_starting_up
Port StartingUp: port=%[port]d
11186 A port is startingto come up STP
stp_trunk_vlan_update
STP TrunkVlan Update:trunk=%[trunk]dvlan=%[vlan]d
11187 Update trunk onSTG for VLAN STP
adj_port_addAdj Port Add:port=%[port]d 11188
Adding port forconsideration foradjacency
STP
adj_port_already
Adj PortAlready:port=%[port]d
11189
Port alreadyunderconsideration foradjacency
STP
adj_considering_port
AdjConsideringPort: port=%[port]d
11190Consideringadjacency forport
STP
stp_bpdu_send_rejected
STP BPDU SendRejected:port=%[port]dvlan=%[vlan]dreason=%[reason]s
11191 Send of BPDU onport rejected STP
lacp_port_sm_mux_timer
LACP SM MuxTimer: port=%[port]d info=%[info]s cur=%[cur]d new=%[new]d
11200 LACP SM MuxTimer for Port STP
lacp_port_sm_ptx_update_timeout
LACP SM PTXUpdateTimeout:port=%[port]d
11201LACP PartnerTimeout Changefor Port
LACP
lacp_l2_flushLACP L2 TableFlush: port=%[port]d
11202LACP L2 TableFlush for thisport
LACP
lacp_port_set_mux
LACP SM MuxTimer: port=%[port]d info=%[info]s cur=%[cur]d new=%[new]d
11203
LACP sets newstate machinemux state onport
LACP
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 21 of 50
lacp_port_marker
LACP SM PTXUpdateTimeout:port=%[port]d
11204LACP MarkerPDU received onPort
LACP
lacp_port_marker_response
LACP MarkerResponse PDU:port=%[port]d
11205LACP MarkerResponse PDUreceived on Port
LACP
lacp_port_sm_tx_nogo
LACP SM TXNoGo: port=%[port]dreason=%[reason]s
11206 LACP PDU notsent on Port LACP
lacp_sm_ptx_timer
LACP PTX PortTimer: port=%[port]d
11207 LACP Port PTXTimer LACP
lacp_sm_rx
LACP SM RX:port=%[port]dreason=%[reason]s
11208 LACP Port PTXTimer LACP
stp_port_enable
STP PortEnable: port=%[port]dvlan=%[vlan]daction=%[action]s
11209
Port is enabledfor STPConsiderationand it had action
STP
stp_port_block
STP PortBlocked:port=%[port]d
11212 Port is blockedby STP STP
stp_port_unblock
STP Port NoBlock: port=%[port]d
11213 Port is notblocked by STP STP
stp_port_disable
STP PortDisable:port=%[port]dvlan=%[vlan]d
11214 STP had disabledthis port STP
vlag_activeVLAG PortActive: port=%[port]d
11300 VLAG port is nowactive STP
vlag_inactiveVLAG PortInactive:port=%[port]d
11301 VLAG port is nowinactive LACP
stp_trunk_port_event
STP TrunkPort Event:port=%[port]dtrunk=%[trunk]dinclude=%[include]d
11306 STP Trunk PortEvent on Port STP
port_starting STP Starting 11307 Starting Port STP
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 22 of 50
_down
Port Down:port=%[port]dtrunk=%[trunk]dflag=%[flags]
Down Handler
send_bpdu_failure
STP BPDUTransmitFailed: port=%[port]dvlan=%[vlan]d
11308STP was notenabled to sendPVST.
STP
mac_ip_denied
mac/ip accessdenied: mac=%[mac]M ip=%[ip]I caller=%[caller]s
11309
Access deniedfor ipaddress/macaddress/port
port by-vxlan by-vlanby-port
stp_edge_port
STP EdgePort: port=%[port]d oper=%[value]s
11310
The given stpport will operatein edge portmode
STP
stp_edge_delay_timer_expired
STP EdgeDelay TimerExpired:port=%[port]dvlan=%[vlan]d
11311Edge delay timerexpired for STPinstance.
STP
stp_migration_delay_timer_expired
STP MigrationDelay TimerExpired:port=%[port]dvlan=%[vlan]d
11312 Migration delaytimer expired forSTP instance.
STP
stp_recent_backup_timer_expired
STP RecentBackup TimerExpired:port=%[port]dvlan=%[vlan]d
11313Recent backuptimer expired forSTP instance.
STP
stp_rcvd_info_timer_expired
STP ReceivedInfo TimerExpired:port=%[port]dvlan=%[vlan]d
11314Received infotimer expired forSTP instance.
STP
stp_recent_root_timer_expired
STP RecentRoot TimerExpired:port=%[port]dvlan=%[vlan]d
11315Recent roottimer expired forSTP instance.
STP
stp_topology_change_timer_expired
STP TopologyChange TimerExpired:port=%[port]dvlan=%[vlan]d
11316Topology changetimer expired forSTP instance.
STP
stp_forward_delay_timer_
STP ForwardDelay Timer 11317 Forward delay
timer expired for STP
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 23 of 50
expiredExpired:port=%[port]dvlan=%[vlan]d
STP instance.
status_recv_vport_delete_config
Receivedstatus deletemessage foruserconfiguredmac=%[mac]Mvlan=%[vlan]dvxlan=%[vxlan]d fromnode=%[sender]x
11318
Received statusdelete messagefor user-configuredvport.
port
stp_invalid_bridge_priority
STP invalidBridgePrioirityReceived:port=%[port]dvlan=%[vlan]dpriority=%[priority]d
11320Received stpbridge priority isinvalid.
STP
stp_bpdu_guard_activated
STP BPDUGuardActivated:port=%[port]dvlan=%[vlan]d
11321BPDU guardactivated onport.
STP
stp_invalid_port_cost
STP Port CostInvalid:port=%[port]dvlan=%[vlan]dcost=%[cost]d
11322STP port costassigned isinvalid.
STP
lacp_timer_status
LACP PortTime Status:%[port]d %[status]s
11323 Port LACP timerstatus. STP
mld_v1
MLDProcessing V1Packet: port=%[port]dvlan=%[vlan]dgroup=%[group]sserver=%[server]stype=%[type]s
11331
MLD snoopingprocessed MLDreport or leavemessages.
MLD
mld_v2
MLDProcessing V2Packet: port=%[port]dvlan=%[vlan]dgroup=%[group]s
11332
MLD snoopingprocessed MLDreport or leavemessages.
MLD
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 24 of 50
server=%[server]stype=%[type]s
mld_v2_record
MLD V2Record: port=%[port]dvlan=%[vlan]dgroup=%[group]sserver=%[server]stype=%[type]s
11333MLD snooping isprocessing a V2record.
MLD
mld_add_sources_failed
MLD SourcesAdd Failed:vlan=%[vlan]dgroup=%[group]shost=%[host]s
11334
MLD snoopingsources addfailed for a givenhost.
MLD
mld_add_host_failed
MLD Add HostFailed: vlan=%[vlan]dgroup=%[group]shost=%[host]s
11335 MLD snoopingadd host failed. MLD
mld_remove_host_failed
MLD RemoveHost Failed:vlan=%[vlan]dgroup=%[group]shost=%[host]
11336MLD snoopingremove hostfailed.
MLD
mld_remove_sources_failed
MLD SourcesRemoveFailed: vlan=%[vlan]dgroup=%[group]shost=%[host]s
11337MLD snoopingremoval ofsources failed.
MLD
mld_v2_report
MLD V2Report: port=%[port]dvlan=%[vlan]dserver=%[server]snumrec=%[type]d
11338MLD snooping isprocessing a V2report.
MLD
mld_drop_packet
MLD droppingpacket: port=%[port]dvlan=%[vlan]digmp-type=%[type]x
11339MLD snooping isdropped apacket.
MLD
mld_ignore_pa MLD ignoring 11340 MLD snooping is MLD
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 25 of 50
cket
packet: port=%[port]dvlan=%[vlan]digmp-type=%[type]x
ignoringreceived MLDpacket
mroute_initMROUTE init:vrouter=%[vrouter]s
11347
mrouter initialize- PIM multicastrouter hasstarted.
mroute
mroute_doneMROUTE done:vrouter=%[vrouter]s
11348
mrouter done -pim multicastrouter hasstopped.
mroute
mroute_add_vif
MROUTE AddingInterface:vrouter=%[vrouter]svif=%[vif]slinkaddr=%[linkaddr]sindex=%[index]dflags=%[flags]x
11349
mrouter isadding a VIF(virtual interface)interface.
mroute
mroute_update_vif
MROUTEUpdatingInterface:vrouter=%[vrouter]svif=%[vif]slinkaddr=%[linkaddr]sindex=%[index]dflags=%[flags]x
11350mrouter isupdating VIFinterface.
mroute
mroute_delete_vif
MROUTE DeleteInterface:vrouter=%[vrouter]svif=%[vif]sindex=%[index]d
11351 mrouter deletesVIF interface. mroute
mroute_flush_vif
MROUTEInterfaceFlush CacheEntry:vrouter=%[vrouter]sinterface=%[interface]s
11352
mrouter flushingmulticast cacheentriesassociated withinterface.
mroute
mroute_delete_mfc
MROUTEDeleting 11353 mrouter deleting
multicast cache mroute
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 26 of 50
Cache Entry:vrouter=%[vrouter]ssource=%[source]sgroup=%[group]s iif=%[iif]s
entry.
mroute_flush_vif
MROUTEInterfaceFlush CacheEntry:vrouter=%[vrouter]sinterface=%[interface]s
11354
mrouterflushingmulticast cacheentriesassociated withinterface.
mroute
mroute_flush_mfc
MROUTE AllFlush CacheEntry:vrouter=%[vrouter]s
11355
mrouterflushing allmulticast cacheentries.
mroute
mroute_sg_count
MROUTE SGConunt:vrouter=%[vrouter]ssource=%[source]sgroup=%[group]svlan=%[vlan]diif=%[iif]sactive=%[active]d
11356
mrouter getstatus forforwardingcache entry.
mroute
mroute_mrtentry_add
MROUTEMRTentry Add:vrouter=%[vrouter]ssource=%[source]sgroup=%[group]s iif=%[iif]d oifs=%[oifs]xupstream=%[upstream]sflags=%[flags]x
11357
mrouter addingeither S,G or *,Gmulticast routingentry.
mroute
mroute_mrtentry_delete
MROUTEMRTentryDelete:vrouter=%[vrouter]ssource=%[source]sgroup=%
11358
mrouter deletingeither S,G or *,Gmulticast routingentry.
mroute
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 27 of 50
[group]s
mroute_mrtentry_update
MROUTEMRTentryUpdate:vrouter=%[vrouter]ssource=%[source]sgroup=%[group]s iif=%[iif]d oifs=%[oifs]xupstream=%[upstream]sflags=%[flags]x
11359
mrouterupdating eitherS,G or *,Gmulticast routingentry.
mroute
mroute_mrtentry_flush
MROUTEMRTentryFlush:vrouter=%[vrouter]s
11360mrouter flushingall multicastroutes.
mroute
mroute_pim_neighbor_add
MROUTE PIMNeighbor Add:vrouter=%[vrouter]slocal=%[local]sneighbor=%[neighbor]s
11361 mrouter addingpim neighbor. mroute
mroute_pim_neighbor_delete
MROUTE PIMNeighborDelete:vrouter=%[vrouter]slocal=%[local]sneighbor=%[neighbor]s
11362 mrouter deletingpim neighbor. mroute
mroute_igmp_group_add
MROUTE IGMPGroup Add:vrouter=%[vrouter]svif=%[vif]sgroup=%[group]s
11363mrouter addingIGMP group oninterface.
mroute
mroute_igmp_group_delete
MROUTE IGMPGroup Delete:vrouter=%[vrouter]svif=%[vif]sgroup=%[group]s
11364mrouter deletingIGMP group oninterface.
mroute
mroute_rp_rou MROUTE RP 11365 mrouter mroute
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 28 of 50
te_update
Route Update:vrouter=%[vrouter]siif=%[iif]s
updating routeto RP - route isvia iif.
l2_modify
l2 entrychanged:caller=%[caller]sreason=%[reason]smac=%[mac]Mvnet=%[vnet]svlan=%[vlan]dvxlan=%[vxlan]d %[changes]s
11372 layer 2 (mac)entry changed vport
l2_delete
l2 entrydeleted:caller=%[caller]sreason=%[reason]smac=%[mac]Mvlan=%[vlan]dvxlan=%[vxlan]d
11373 layer 2 (mac)entry deleted vport
l3_modify
l3 entrychanged:caller=%[caller]sreason=%[reason]s ip=%[ip]I vlan=%[vlan]dvxlan=%[vxlan]d %[changes]s
11374 layer 3 (ip) entrychanged vport
l3_delete
l3 entrydeleted:caller=%[caller]sreason=%[reason]s ip=%[ip]I vlan=%[vlan]dvxlan=%[vxlan]d
11375 layer 3 (ip) entrydeleted
stp_mst_port_state
STP PortState Change:port=%[port]dinstance=%[instance]d:%[old_state]s-> %[state]s
11383port changed stpstate port
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 29 of 50
stp_port_modified
STP portmodified 11394 STP port has
been modified port
tacacs_missing_role
server=%[server]suser=%[user]s: No role orpriv-lvl inauthorizationresponse
11417
role missingfrom TACACS+shellauthorizationresponse
tacacs
hog_host_violation
hogprotectiontriggered,moving hostmac=%[mac]Mvlan=%[vlan]dvxlan=%[vxlan]dport=%[port]dfrom-cpu-queue=%[from_queue]sto-cpu-queue=%[to_queue]
11418
host end-pointusing too muchbandwidth in cpuqueue, moved tohog queue
system
hog_host_clear
cpu hogprotectioncleared,restoringhost mac=%[mac]M vlan=%[vlan]dvxlan=%[vxlan]dport=%[port]dfrom-cpu-queue=%[from_queue]sto-cpu-queue=%[to_queue]s
11419
host end-pointno longer usingtoo muchbandwidth in cpuqueue, movedback to originalqueue
system
hog_port_violation
more thanmax=%[max]dhog hosts onport=%[port]d,redirectingall hostsfrom-cpu-queue=%[from_queue]sto-cpu-queue=%[to_queue]s
11420
Too many hoghosts on a port,moving all hostsfrom port to hogqueue
system
hog_port_clear
cpu hogprotectioncleared,restoringport=%[port]d
11421
No longer toomuch bandwidthused on port,moved back tooriginal queue
system
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 30 of 50
from-cpu-queue=%[from_queue]sto-cpu-queue=%[to_queue]s
err_disabled_recovery
Err-Disabledport hasrecovered:port=%[port]d.
11425err-disabled porthas recoveredpost timeout
port
mac_exceeded_log
Number ofMACs on porthave beenexceeded forport=%[port]d
11426
Number ofMACs on porthave beenexceeded
port
mac_exceeded_drop
Number ofMACs on porthave beenexceeded forport=%[port]d, packetdropped
11427
Number of MACson port havebeen exceeded,packet dropped
port
mac_exceeded_disable
Number ofMACs on porthave beenexceeded forport=%[port]d, portdisabled
11428
Number of MACson port havebeen exceeded,port disabled
port
stp_root_guard_blocked
STP RootGuardActivated:port=%[port]dtried tobecome non-designated,moved to rootinconsistentstate(listening)
11429
root guardactivated onport, moved toroot inconsistentstate (listening)
STP
stp_root_guard_unblocked
STP RootGuardunblocked:port=%[port]drestored,moving out ofrootinconsistentstate
11430
root guardunblocked onport, moving outof rootinconsistentstate
STP
lacp_port_event_up
Port LACP Upfor port=%[port]d
11500 LACP port is up lacp-port-event
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 31 of 50
lacp_port_event_down
Port LACPDown forport=%[port]d
11501 LACP port isdown lacp-port-event
lacp_port_event_expired
Port LACPExpired forport=%[port]d
11502 LACP port isexpired lacp-port-event
lacp_port_event_defaulted
Port LACPDefaulted forport=%[port]d
11503 LACP port isdefaulted lacp-port-event
stp_root_guard_bpdu_timer_expired
STP RootGuard BPDUTimerExpired:port=%[port]dvlan=%[vlan]d
11506root guard BPDUtimer expired forSTP instance.
STP
lacp_port_event_rx
Port LACPPDU receivedfor port=%[port]d
11507 LACP portreceived PDU STP
lacp_port_event_tx
Port LACP PDUtransmit forport=%[port]d
11508 LACP porttransmit PDU lacp-port-event
port_defaulted
Port=%[port]dhas LACPdefaulted
11509 A port has LACPdefaulted
port
port_expiredPort=%[port]dhas LACPexpired
11510 A port has LACPexpired port
certificate_expiring
%[cert]scertificateexpiring in %[days]d days
11511Show how manydays left forcertificate expiry
system
certificate_expired
%[cert]scertificateexpired
11512Display theexpiredcertificate
system
systemup_alert
System is upfor service 11513
Display thesystem statusfor service
system
fanmon_change_speed
Current tempis %[temp]dC, changingfans to speed%[speed]d RPM
31006fan monitorchanging systemfan speeds
system
openflow_incorrect_configuration
Openflowserviceconfigurationerror-string
40000
IncorrectOpenflowserviceconfiguration.
Openflow
openflow_prot Openflow 40001 Openflow Openflow.
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 32 of 50
ocol_errprotocolerror type:msg
protocol error.
openflow_invalid_protocol_header
Openflowinvalidprotocolheader error
40002 Openflow invalidprotocol header. Openflow
openflow_controller_err
Openflowcontrolleripaddr: error
40004Openflowcontrollercommunication
Openflow
openflow_nvOS_err
Openflow nvOSerrorcommand:error-id
40005 Openflow nvOSerrors Openflow
openflow_nvOS_res
Openflow nvOSerrorcommand: res
40006 Openflow nvOSerrors Openflow
openflow_controller_status
Openflowcontrolleripaddr:status
40007Openflowcontrollercommunication
Openflow
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 33 of 50
System Log Messages
Identifier Message Code Description Severity
syslog_send_failed
Failed to sendlog message tosyslog serverserver(s) error-message(s)
20000Probable resourceexhaustion on UDPsocket.
Error
syslog_hostname_lookup_failed
Failed toresolve hostnamehost(s) forsyslog error-message(s)
20001
Possible DNSproblems orincorrect hostnamefor syslog server.
Error
system_repeats
Last idsmessage(s)repeated numbertimes(s)
20002 Compress repeatedmessages. Note
event_repeats
Last %[msgs]dmessage(s)repeated %[times]d time(s)
20003 Compress repeatedmessages. Note
audit_repeats
Last %[msgs]dmessage(s)repeated %[times]d time(s)
20004 Compress repeatedmessages. Note
reset_counters
system logcounters resettimestamp %[timestamp]s
20005 Reset system logcounters. Note
syslog_tls_server_down
tcp-tlsconnection tosyslog server=%[server]s down.Logs are notgetting exported
20006
Connection to syslogexport tcp/tls serveris down. syslogexport to externalserver is nothappening
Error
syslog_tls_server_restored
tcp-tlsconnection tosyslog server=%[server]srestored. Logexport isoperational
20007Connection to syslogexport tcp/tls serveris restored.
Error
syslog_tls_server_dropped
syslog exportlog messages tosyslog server=%[server]sgetting dropped
20008Syslog exportmessage(s) to tcp/tlsserver dropped.
Error
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 34 of 50
syslog_tls_server_delayed
syslog exportlog messages tosyslog server=%[server]sgetting delayed
20009Syslog exportmessage(s) to tcp/tlsserver delayed.
Error
generic_platform_audit
platform auditmessage: %[msg]s 20010 Platform audit
message
container_logcontainer logmessage: %[msg]s 20011 Logs from the
containers
os_logsOS audit logmessage: %[msg]s 20012
Logs from theOperating systemauditing
mon_start nvOS_mon startup 30000 Monitoring starting. Note
mon_exitExiting becausereason(s)
30001 Monitoring exitingfor various reasons. Warn
mon_rebootStarting commandcmd(s)
30004 Monitoring starting. Note
mon_restart_nvOSd
Monitorrestarting nvOSd 30005 Restarting nvOSd Note
mon_failure_detected
Monitor detectedfailurefailure(s)
30006 Monitor detected afailure. Warn
mon_resetReset nvOSdconfig 30007
nvOS_mon isresetting nvOSdconfiguration.
Note
mon_grub_gen
Regeneratinggrubconfigurationfor new bootenvironment.
30008 nvOS_mon isregenerating grub. Note
mon_restart_tomcat
Monitorrestartingtomcat.
30009 Restarting tomcat. Note
mon_cpu_usage_high
High cpu usagedetected. 30010 High CPU usage
detected. Note
mon_memory_usage_high
High memoryusage detected 30011 high memory usage
detected. Note
mon_disable_ports
nvOSd cannot berevived;disabling portsto preventheadlessswitching.
30012
Monitor failed torestart nvOSd;disabling ports toprevent headlessswitching.
Critical
mon_auth_failed
Userauthorizationfailed for username(s), pid
30013 User authorizationfailed. Note
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 35 of 50
pid(d), ip
mon_keepalive_hung
nvOS_mon ispossibly stuck !%[action]s
30014
nvOS_monkeepalive_checkerthread is possiblyhung.
Critical
mon_autoreboot_cancel
%[reason]s; thesystem will notbe rebooted.
30015
System will not berebooted; auto-reboot is disabled orsoftware-upgrade isin progress.
Critical
mon_autoreboot_failed
System failed toauto-reboot: %[reason]s
30016System failed toauto-reboot: %[reason]s
Critical
mon_cpu_usage_higher_than_seventy
CPU usage higherthan 70 percentdetected
30017CPU usage higherthan 70 percentdetected
Critical
mon_memory_usage_higher_than_seventy
Memory usagehigher than 70percent detected
30018Memory usagehigher than 70percent detected
Warn
fanmon_fan_status
Controllercontroller-idfan fan-id speedrpm RPM
31000 Status of a fan afterit becomes active. Note
fanmon_fan_missing
Controllercontroller-idfan fan-id ismissing
31001 There is no fan in thefan slot. Warn
fanmon_fan_status_max
Controllercontroller-idfan fan-id ismax
31002 Fan is set tomaximum speed. Note
fanmon_fan_fault
Controllercontroller-idfan fan-idfault:fault(s)
31003 There is a problemwith the fan. Warn
fanmon_fan_fault_compensate
One fan fault isdetected sosetting allother fans tomax speed tocompensate.
31004 One fan is faulty onthe system. Warn
fanmon_poweroff
Fan monitorpowering downsystem due tofaults or overtemp.
31005Fans are not workingproperly on theserver-switch.
Critical
fanmon_change_speed
Current temp istemp C, changingfans to speed
31006Fans are changingspeeds to cool thesystem.
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 36 of 50
speed RPM
smf_nvOSd_startsmf startingnvOS 31007 nvOS starting. Note
smf_nvOSd_stopsmf stoppingnvOS 31008 nvOS stopping. Note
openstack_error
Openstack error:%[name]s: %[func]s - %[err]s
31009 Openstack errors onthe nvOS CLI
openstack_informational
Openstack info:%[name]s: %[func]s - %[info]s
31010Openstackinformationalmessages
hw_route_prec0_detected
F64 count=%[count]dhardware routeswith invalidprecedencedetected
31011
Aquila hardwareroute with invalidprecedencedetected
Critical
fanmon_ipmitool_read
unexpectedipmitool output%[lines]s
31012fan monitor: ipmitoolreturned insufficientinformation
Note
ipsla_unreachable
%[name]s: %[msg]s - %[route_info]s
31013 IPSLA: linktrack ip isunreachable Note
ipsla_reachable%[name]s: %[msg]s - %[route_info]s
31014 IPSLA: linktrack ip isreachable Note
fanmon_fan_info
Current temp %[temp]d Currentspeed %[rpm]dRPM
31015Show currenttemperature and FanSpeed setting info
Note
upgrade_error%[name]s: %[func]s - %[err]s
30201 Software Upgradeerrors Warn
upgrade_informational
%[name]s: %[func]s - %[info]s
30201Software Upgradeinformationalmessages
Note
hwmon_start=== nvOSd_hwmonstart === 32000 nvOSd_hwmon
startup Note
hwmon_exitexiting because%[reason]s 32001
hardware monitorexiting for somereason
Warn
hwmon_power_supply_fault
power supply %[name]s fault 32002 power supply has
failed Critical
hwmon_power_supply_ok
power supply %[name]s has 32003 power supply OK Note
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 37 of 50
recovered fromfaulted state
hwmon_fan_faultfan %[name]sfault 32004 fan has failed Critical
hwmon_fan_okfan %[name]s hasrecovered fromfaulted state
32005 fan ok Note
hwmon_sensor_fault
temperaturesensor %[name]sfault
32006 temperature sensorfault Warn
hwmon_sensor_ok
temperaturesensor %[name]shas recoveredfrom faultedstate
32007 temperature sensorok Note
hwmon_temp_warning
%[name]s at %[t1]dC, shutdownat %[t2]dC
32008 high temperaturewarning Warn
hwmon_temp_Critical
%[name]s at %[t1]dC, shutdownat %[t2]dC
32009 high temperatureCritical Critical
hwmon_temp_shutdown
shutting downsystem: %[name]sat %[t1]dC
32010 high temperaturesystem shutdown Critical
hwmon_shutdown_failed
system hightemperatureshutdown failed
32011high temperaturesystem shutdownfailed
Critical
hwmon_temp_ok%[name]s at %[t1]dC,temperature ok
32012 temperature OK Note
system_dropLost drops-idmsgs
10002
Unable to deliversystem log(s) tonvlogd so systemlogs dropped.
Warn
update_find_server_failed
Failed tocontact updateserver.
11006 Failed to find updateserver. Warn
update_wrong_redirect
Unexpectedredirect url(s)from updateserver.
11007
Got an unexpectedredirect from httpupdate serverlookup.
Warn
nvOSd_start
nvOSd start:version=version(s)changeset=changeset(s)branch=branch(s)
11008 nvOSd startup Note
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 38 of 50
pkt_alloc_failed
feature(s)failed toallocate a sendbuffer.
11009Failed to allocate apacket for sendingfrom the CPU
Warn
syscall_failed_Critical
feature(s):syscall(s)failed: error
11012 A system call failed. Critical
resstart_nvOSdRestartingexe(s)
11013 Restarting nvOSd. Note
restart_nvOSd_failed
Failed torestart exe(s):error-mgs
11014 Failed to restartnvOSd Critical
nvOSd_init_failed
nvOSd failed tostart:feature(s):error-mgs
11015 nvOSd was unable tostart. Critical
loop_detected
LOOP: mac(s)vlan(s) was onport_type(s)old_port-id((ip(s)), nownew_port-id)((new_ip(s))
11016 Detected an L2 loop. Note
mac_moved
MOVING MACmac(s), fromold_port_type(s)old_port-id(old_ip(s))new_port_type(s)new_port-id(new_ip(s))
11017 MAC moved fromone port to another. Note
simulator_modeFailed to initswitch hardware. 11018
Simulator modeentered but not fromcommand line.
Critical
fabric_joinedJoined fabricfabname(s).
11019 Switch joined afabric. Note
fabric_unjoinedUnjoined fabricfabname(s)
11020 Switch un-joined afabric. Note
config_importedImportedconfigurationfrom file(s).
11021 Imported a newconfiguration. Note
stp_switch_enable_failed
STP failed toinitialize forswitch hardware.
11028STP initialization forunderlying hardwareswitch failed.
Critical
stp_default_spanning_tree_failed
STP Failed toCreate DefaultSpanning Tree:vlan= vlan-id
11029Unable to create theSpanning Tree fordefault VLAN.
Critical
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 39 of 50
stp_flow
STP Failed toinstall flow(s)fpr BPDUreception:flow(s)
11030
Unable to install STPflow(s) for thereception of STPpackets.
Critical
stp_worker_thread_failed
STP failed tocreate workerthread:vlan=vlan-id
11031STP was unable tocreate worker threadfor Spanning Tree.
Critical
stp_config_failed
Loading andapplication STPconfigurationfailed.
11041The loading andapplication of STPconfiguration failed.
Warn
stp_switch_port_state
STP PortFailure:port=portvlan=vlan-idtrunk=trunk-id
11045Unable to set theport state for theport on the VLAN.
Critical
stp_trunk_port_state
STP Set PortState: port vlan trunk
11046 Invalid trunk in useby the spanning tree Warn
igmp_switch_init
IGMP snoopingunable toinitializeswitch hardwarefor groups.
11047
igmp was unable toinitialize switchhardware for thegroup.
Critical
igmp_flow_addIGMP snoopingunable to addflow flow(s).
11048igmp was unable toadd a flow for IGMPpacket processing.
Warn
igmp_flow_remove
IGMP snoopingnot able toremove flowflow(s).
11049
IGMP snoopingunable to removeflow for IGMPprocessing.
Warn
igmp_query_start
IGMP snoopingunable to startquery statemachine.
11050IGMP snoopingunable to start querystate machine.
Warn
igmp_query_stop
IGMP snoopingunable to stopquery statemachine.
11051IGMP snoopingunable to stop querystate machine.
Warn
igmp_switch_fini
IGMP snoopingunable to haltswitch hardwarefor groups.
11052IGMP snoopingunable to halt switchhardware for groups.
Warn
igmp_static_load
IGMP snoopingunable to loadstatic IGMPgroup.
11053IGMP snoopingunable to load staticIGMP group.
Warn
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 40 of 50
igmp_static_source_load
IGMP snoopingunable to loadstatic IGMPsource list.
11054IGMP snoopingunable to load staticIGMP source list.
Warn
igmp_floodingIGMP floodingnot enabled. 11055 IGMP flooding not
enabled. Warn
igmp_group_add_failed
IGMP Group AddFailed: vlan-idgroup(s)
11071IGMP snoopingfailed to add a groupto switch hardware.
Warn
igmp_group_remove_failed
IGMP GroupRemove Failed:vlan-id group(s)
11072
IGMP snoopingfailed to remove agroup from switchhardware.
Warn
software_upgrade_initiated
nvOS softwareupgradeinitiated forversion(s).
11073
Software upgradeinitiated;downloading andinstalling newpackages.
Note
software_upgrade_complete
System and nvOSsoftware upgradecompleteversion(s).
11074System and nvOSsoftware upgradecomplete.
Note
software_upgrade_failed
nvOS softwareupgrade failed. 11075 nvOS software
upgrade failed. Warn
system_rebootSystem rebootinitiated bynvOS.
11076 System rebootinitiated by nvOS. Note
system_reboot_failed
System rebootinitiated bynvOSd failed.
11077System rebootinitiated by nvOSdfailed.
Warn
lldp_agent_create_thread_failed
LLDP AgentThread CreateFailed: mac(s)group(s) error
11079Creation of threadsfor LLDP Agentfailed.
Warn
lldp_flow_add_failed
LLDP Flow AddFailed: flow(s) 11080
Adding flow for LLDPpacket receptionfailed.
Warn
lldp_flow_remove_failed
LLDP Flow RemoveFailed: flow(s) 11081
Removing flow forLLDP packetreception failed.
Warn
evb_platform_not_supported
EVB is notsupported onthis platform:port
11089 EVB is not supportedon this platform. Warn
evb_ecp_not_enabled
EVB ECP is NotEnabled: port 11090
Received EVB TLVwith ECP is notenabled.
Warn
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 41 of 50
evb_flow_remove_failed
EVB Flow RemoveFailed:flowstr(s)
11095 Unable to removespecified EVB flow. Warn
lldp_agent_create_failure
LLDP AgentCreate Failed:agent(s)
11111
Failed to create LLDPagent for one ofthree agentaddresses.
Warn
stats_log_open_failed
Log file openfailed. 11140 The log file failed to
open. Warn
container_rebuild_start
container=%[container]srebuild isstarted
11141 container rebuild isstarted
container_rebuild_end
container=%[container]srebuild iscompleted
11142 container rebuild iscompleted
all_container_rebuild
all containersare rebuilt 11143 all containers are
rebuilt
loop_broken
A loop wasbroken onport/vlan formac/ip
11180A loop was broken ona port or VLAN for aMAC or IP address.
Warn
loop_stp
A loop wasdetected thatSTP should haveprevented.
11181STP did not preventa loop on thenetwork.
Warn
update_auto_upgrade
Update serverinitiatedupgrade
11210The update serverinitiated an upgradefor nvOS.
Note
update_errorUpdate serversent an errormessage
11211The update serversent an errormessage.
Warn
ps_initial_status
Power supplyinitial status. 11302 The initial status of
the power supplies. Warn
fan_initial_status
Fan initialstatus 11303 The initial status of
the fans. Warn
ps_status_changePower supplystate change 11304
The status of thepower supplieschanged.
Warn
fan_status_change
Fan statuschange 11305 The status of the
fans changed. Warn
fabric_node_duplicate_ip
Fabric node hasthe same ip=%[ip]I as thelocal node,cannot send toit
11319
Fabric node has thesame IP as the localnode, cannot send toit.
Warn
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 42 of 50
upgrade_error
software upgradeerror: %[name]s:%[func]s - %[err]s
11324 Software Upgradeerrors Warn
upgrade_informational
software upgradeNote: %[name]s:%[func]s - %[info]s
11325Software Upgradeinformationalmessages
Note
upgrade_rebootSystem rebootinitiated byupgrade agent
11326System rebootinitiated by softwareupgrade
Note
upgrade_reboot_failed
System rebootinitiated byupgrade agentfailed
11327System rebootinitiated by softwareupgrade failed
Warn
openstack_nat_failed
Failed to setupNAT on theOpenStackcontroller %[name]s
11328 Failed to configureNAT for OpenStack Warn
mac_tunnel_to_port
MOVING MAC=%[mac]M, vlan=%[vlan]d fromtunnel=%[tunnel]s ip=%[old_ip]Ito port=%[port]dip=%[new_ip]I %[caller]s
11329 MAC moved from atunnel to a port Warn
mac_port_to_switch
MOVING MAC=%[mac]M, vlan=%[vlan]d fromswitch=%[old_sw]s port=%[old_port]d ip=%[old_ip]I toswitch=%[new_sw]s port=%[new_port]d ip=%[new_ip]I %[caller]s
11330MAC moved from aport to anotherswitch
Note
mld_flow_add
mld snoopingunable to addflow: flow=%[flow]s
11341MLD was unable toadd a flow for MLDpacket processing.
Warn
mld_flow_remove
mld snooping notable to removeflow: flow=%[flow]s
11342
MLD snoopingunable to removeflow for MLDprocessing.
Warn
mld_query_start
mld snoopingunable to startquery statemachine
11343MLD snoopingunable to start querystate machine.
Warn
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 43 of 50
mld_query_stop
mld snoopingunable to stopquery statemachine
11344MLD was not able tostop the query statemachine.
Warn
mld_static_loadmld snoopingunable to loadstatic mld group
11345MLD snoopingunable to load staticMLD group.
Warn
mld_static_source_load
mld snoopingunable to loadstatic mld groupsource list
11346
MLD snoopingunable to load staticmld group sourcelist.
Warn
xact_node_ignored
Ignoring offlinecluster nodename=%[name]sfor transactiontid=%[tid]d
11366ignored offlinecluster node fortransaction.
Warn
xact_recover
Transactionsout-of-syncdetected, rolledforward fromold=%[old]d tonew=%[new]d vianode=%[node]s
11367auto-recovered fromtransactions beingout of sync.
Warn
xact_recover_failed
Transactionauto-recoverfailed: %[msg]s
11368 auto-recoverattempted but failed. Warn
ip_moved
Moving ip=%[ip]Ifrom old-mac=%[old_mac]M tonew-mac=%[new_mac]M
11369IP address movedfrom one MAC toanother MAC
Note
software_license_expiring
softwarelicense(s)expiring sooncode=%[code]sexpires_on=%[expires_on]s
11370 software license(s)expiring
software_license_expired
softwarelicense(s) haveexpired code=%[code]sexpired_on=%[expires_on]s
11371 software license(s)have expired
l2_check_missing
Add missing l2entry tohardware: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d port=%[port]d result=%[result]s
11376Add layer 2 entrythat was missing inhardware
Warn
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 44 of 50
l2_check_bad_port
Fix l2 entry inhardware withincorrect port:mac=%[mac]svlan=%[vlan]dvxlan=%[vxlan]dold_port=%[old_port]dnew_port=%[new_port]dresult=%[result]s
11377Fix layer 2 entry inhardware withincorrect port
Warn
l2_check_orphaned
Remove orphanedl2 entry fromhardware: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d port=%[port]d result=%[result]s
11378
Remove orphanedlayer 2 entry inhardware (not insoftware table)
Warn
mac_move_denied
MOVE DENIED mac=%[mac]M vlan=%[vlan]d vxlan=%[vxlan]d fromswitch=%[sw]nport=%[port]d todeny-switch=%[deny_sw]n deny-port=%[deny_port]dreason=%[reason]s
11379 Mac moved notallowed Note
host_port_loop_detected
Looping trafficdetected onhost-port=%[port]d vlan=%[vlan]d. Trafficon thisport/VLAN willbe ignored untilloop resolved
11380 loop detected onhost port Warn
host_port_loop_resolved
Traffic hasstopped loopingon host-port=%[port]d vlan=%[vlan]d
11381 loop on host port isno longer happening Note
owner_mac_moved
caller=%[caller]s owner=%[owner]n mac=%[mac]Mvlan=%[vlan]dmoved from old-local-port=%[old_port]d tonew-local-port=%[new_port]d
11382other switch's macmoved from onelocal port to another
Note
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 45 of 50
mstp_set_port_state_failed
STP Port StateFailure: port=%[port]dinstance=%[instance]d
11384Unable to set the stpstate for the port onthe MST instance
Critical
mac_port_to_tunnel
MOVING MAC=%[mac]M, vnet=%[vnet]s vlan=%[vlan]d fromport=%[port]dip=%[old_ip]I totunnel=%[tunnel]s ip=%[new_ip]I%[caller]s
11385 mac moved from aport to a tunnel Note
cluster_vlag_l2_update_failed
Updating mac=%[mac]M vnet=%[vnet]s vlan=%[vlan]d frompeer update tovlag port port=%[port]d failed,cluster may beout-of-sync:reason=%[reason]
11386
updating mac to vlagport in response topeer status updatefailed, cluster L2 maybe out of sync
Warn
cluster_tunnel_l2_update_failed
Updating mac=%[mac]M vxlan=%[vxlan]d tunnel=%[tunnel]s frompeer updatefailed, clustermay be out-of-sync: reason=%[reason]s
11387
updating tunnel macin response to peerstatus update failed,cluster L2 may beout of sync
Warn
cluster_comm_l2_update_failed
Updating mac=%[mac]M vnet=%[vnet]s vlan=%[vlan]d frompeer update tocluster portport=%[port]dfailed, clustermay be out-of-sync: reason=%[reason]s
11388
updating mac tocluster link inresponse to peerstatus update failed,cluster L2 may beout of sync
Warn
l2_check_bad_tunnel
Fix l2 entry inhardware withincorrecttunnel: mac=%[mac]s vnet=%[vnet]s vlan=%[vlan]d vxlan=%[vxlan]dold_tunnel=%[old_tunnel]snew_tunnel=%
11389Fix layer 2 entry inhardware withincorrect tunnel
Note
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 46 of 50
[new_tunnel]sresult=%[result]s
l2_check_mismatch_vport
Mismatched vportentry: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]dhw_vlan=%[hw_vlan]dhw_vxlan=%[hw_vxlan]dresult=%[result]s
11390 Mismatched vportentry Note
l2_check_mark_port_mac
Marked vport asport-mac: mac=%[mac]s vlan=%[vlan]d vxlan=%[vxlan]d
11391 Marked owned localvport as port-mac Warn
l2_check_delete_port_mac
Delete invalidport-mac vport:mac=%[mac]svlan=%[vlan]dvxlan=%[vxlan]d
11392Delete port-mac thatshould not be invport table
Warn
hostid_collision_detected
Our hostid isbeing used byanother node %[node_name]s
11393received keep-alivefrom another nodehaving same hostid
Critical
mirror_to_cpu_configured
Mirror to CPUconfigured onvFlow %[vflow_name]s
11395 Mirror to CPUconfigured Note
low_disk_space
Disk Space Usagehas exceededthreshold of 70percent
11396 Disk space usageexceeds 70 percent Warn
stp_vnet_port_recv
received STPBPDU on vnetport: port=%[port]d
11397 received an STPBPDU on a vnet port Warn
igmp_disabledDisabling IGMPon vlan: vlan=%[vlan]d
i11398 Disabling IGMP onvlan Note
igmp_enabledEnabling IGMP onvlan: vlan=%[vlan]d
11399 Enabling IGMP onvlan Note
l2_check_hw_invalid
Remove invalidl2 entry fromhardware: mac=%[mac]s vnet=%[vnet]s vlan=%
11400Remove invalid layer2 entry in hardware(incorrect HW entry)
Warn
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 47 of 50
[vlan]d vxlan=%[vxlan]d port=%[port]d tunnel=%[tunnel]sresult=%[result]s
congestion_on_port
Congestiondetected onport=%[port]d
11401
Congestion detectedon port. Positiveicongdrop/ocongdrop
Critical
congestion_relieved_on_port
Congestionrelieved onport=%[port]d
11402 Congestion relievedon port. Critical
fabric_node_status
%[node_name]s:Node statuschanged to %[status]s
11403 fabric node statechange Note
mld_disabledDisabling MLD onvlan: vlan=%[vlan]d
11404 Disabling MLD onvlan Note
mld_enabledEnabling MLD onvlan: vlan=%[vlan]d
11405 Enabling MLD on vlan Note
vlan_public_id_mismatch
vnet=%[vnet]svlan=%[vlan]dpublic-idmismatch whilecluster offline
11406while cluster wasoffline vlan public-idmismatch happened
Error
vlan_port_node_ignored
Ignoring offlinecluster nodename=%[name]swhile assigningpublic vlan tovnet=%[vnet]svlan=%[vlan]d
11407ignored offlinecluster for privatevlan port assignment
Warn
vlan_public_id_fail
failed to setpublic-vlan forvnet=%[vnet]svlan=%[vlan]dmsg=%[msg]s
11408failed to set publicvlan id while handlingcluster status update
Error
bad_xcvr_detected
unable to accessI2C bus;possible badtransceiver
11409
unable to access I2Cbus; possibly a badtransceiver isinserted
Error
tacacs_server_error
server=%[server]s TACACS+authorizationdisabled due torepeated servererrors
11414
Repeated TACACS+server errors.TACACS+authorizationdisabled
Critical
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 48 of 50
tacacs_server_ok
TACACS+ serverhas recoveredfrom errors.TACACS+Authorizationenabled
11415
server=%[server]sTACACS+authorizationenabled due toserver errorsresolved
Note
dhcp_untrusted_msg
received DHCPserver messagefrom anuntrusted portreceived DHCPserver messagefrom anuntrusted port
11416
DHCP servermessage receivedfrom untrusted port=%[port]d server-ip=%[ip]I
Warn
fabric_guard_loop_detect
Fabric-guarddetected loop 11422
Fabric-guarddetected a loop onport %[port]d. Portblocked.
Note
replace_offline_node
new nodereplacingoffline nodewith the samelocation id
11423
loc-id=%[loc_id]d:node=%[name]snode-id=%[node_id]d replacing old-node=%[old_name]sold-node-id=%[old_node_id]d
Note
loc_id_conflict
loc-id=%[loc_id]d owned by node=%[name]s node-id=%[node_id]d,ignore messagefrom conflict-node=%[old_name]s conflict-node-id=%[old_node_id]d
11424
two nodes with thesame loc-id is notallowed, ignoringlatest
Warn
ntp_server_syncNTP server isunresolvable/unreachable
11431 NTP server notresolvable/reachable Critical
xact_rollforward_ignore_error
Transactionsrollforward tid=%[tid]d cmd=%[cmd]s failedresult=%[result]R, ignoringerror
11432xact rollforwardfailure overridden byuser
Warn
xact_rollback_ignore_error
Transactionsrollback tid=%[tid]d cmd=%[cmd]s failedresult=%[result]R, ignoringerror
11433 xact rollback failureoverridden by user Warn
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 49 of 50
nxu_module_fw_upgrade
Installedversion: %[inst]s; availableversion %[avail]s
11434One or more Luteraxcvrs require modulefirmware upgrade
nxu_chipset_fw_upgrade
Installedversion: %[inst]s; availableversion %[avail]s
11435One or more Luteraxcvrs require chipsetfirmware upgrade
sensor_unavailable
sensor %[name]scannot beaccessed
11436 sensor cannot beread by BMC
ipv6_raguard_ra_port_drop
Dropping RA fromport=%[port]d. %[msg]s
11504Drop RA packet fromport according to RAGuard Policy
ipv6_raguard_ra_port_drop
Dropping RA fromvlan=%[vlan]d. %[msg]s
11505Drop RA packet fromvlan according to RAGuard Policy
Warn
disk_health_below_RMA
The disk healthlevel %[current]d issignificantlybelowrecommendedlevel %[rma]d,please notifyPluribus TACimmediately
11514
The disk health isbelow the minimumrequired to workneeds to be RMAed
disk_health_below_minimum
The disk healthlevel %[current]d is belowrecommendedlevel %[rma]d,please notifyPluribus TAC
11515The disk health isbelow the minimumrequired to work
disk_health_filesystem_readonly
The filesystem %[part]s is inRead Only mode,please notifyPluribus TACimmediately
11516 The disk partition ismounted read-only
syscall_failed_Critical
feature(s)syscall(s)failed: error(s)
40003 A system call failed. Critical
Netvisor One Log Messages Guide Version 5.1.2 - Copyright © 2010-2020 Pluribus NetworksPage 50 of 50
About Pluribus Networks
Pluribus Networks is simplifying the Software-Defined Data Center with its simple, dynamic and secureAdaptive Cloud Fabric architecture, enabling organizations to build scalable private and public clouds thatimprove service velocity, performance, and reliability.
The company's innovative Netvisor One software virtualizes open networking hardware to build a holistic,distributed network that is more intelligent, automated and resilient.
The company's Insight Analytics platform leverages embedded telemetry and other data sources to enablepervasive visibility across the network to reveal network and application performance that speedstroubleshooting and improves operational and security intelligence. Pluribus Networks has receivedventure funding from Temasek Holdings, NEA, Menlo Ventures, and AME Cloud Ventures.
Pluribus Networks is headquartered in Santa Clara, California, with development and support centers inBangalore, India; Phoenix, AZ; Dallas, TX; and Hong Kong, PRC.
For additional information contact Pluribus Networks at [email protected], or visitwww.pluribusnetworks.com.
Follow us on Twitter @pluribusnet
Corporate Headquarters
Pluribus Networks, Inc.5201 Great America Parkway, Suite 422Santa Clara, CA 95054
1-855-438-8638 / +1-650-289-4717
India Office
Pluribus Networks India Private LimitedIndiqube Brigade Square, 4th Floor21, Cambridge RoadBangalore 560008