ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753 ABB NEPLAN ® Successfully used all over the world Planning and optimization system for electrical, gas, water and district heating networks 17/10/05

Transcript of Neplan_E.pdf

Page 1: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

NEPLAN®

Successfully used all over the world

Planning and optimization system for electrical, gas, water and

district heating networks 17/10/05

Page 2: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Data Management, Interactive Graphics NEPLAN

Data management All equipment can be entered graphically and/or table oriented (like in a excel sheet)

A single line diagram can easily be generated through a very user friendly CAD systems.

There is no restriction on drawing sizes and number of nodes and elements.

Extensive editing functions like undo, redo, delete, copy, move and zoom for processing the network diagram are available. An element can be moved from one node to an other node without deleting the element.

OLE functionality: Data and graphic can be moved to and from third party software (like MS-Excel, MS-Word). Project documentation was never easier.

The equipment data are entered in dialogs, with plausibility checks provided. A coloring tool helps to show which data is needed for which analysis (e.g. short circuit, transient stability etc.)

Integrated Variant Manager (insert, delete, append, compare variants, compare results, etc.).

ASCII file or SQL database oriented import/export functions for exchanging network data, topology data and load data are available.

Interfaces to external programs (e.g. measured data acquisition systems) can be implemented.

Import of a geographic map as a background graphic, for easier schematic capturing.

Import of almost any raster and vector graphic files (e.g. PCX and DXF files).

Graphics can be exported as raster files (e.g. JPG, which can be used in any internet web browser).

Option for combining and separating networks. Any number of independent network areas and zones are possible. Each element and node can belong to any independent area and zone.

Extensive functions for network statistics and network documentations are available.

A state of the art library manager with extensive libraries for each element type facilitates data entry.

All computation modules access a shared database.

Integrated chart manager allows to analyze and compare all results from all variants.

Languages: program and manual in English, French, Spanish, German and Italian

Page 3: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Multi-Diagram and Multi-Layer-Technique i-Diagram and Multi-Layer-Technique

Multi-Diagram and Multi-Layer-Technique

A network can be entered in several different diagrams, so that the HV network, for instance, is in one diagram, and the MV network in one or more other diagrams.

Each diagram can have any number of graphic layers. These layers can be colored, locked, hidden or shown.

Zooming into stations: in the overview diagram, a station is shown as a black box, while in another diagram it is depicted in detail, with all its breakers, protective devices and instruments.

Topological linkage of elements over more than one diagram.

All diagrams will be considered for the various analysis (e.g. load flow).

One element can have more than one graphical representation in the same diagram or in different diagrams.

OLE. copy/paste graphic data from and to MS-Word

Data Management, Interactive Graphics NEPLAN

Variant Management Non-redundant storage and management of

variants.

For each network, you can select

* any desired switch states (topology file)

* any desired loading states (loading file)

For each network you can define and store any desired number of variants and subvariants (variant tree). In the variant data, only the differences from the parent variant are saved.

Variants can be compared, merged and deleted.

The diagrams of different projects and variants can be displayed at the same time

Results from two different variants can be displayed on the diagram in one result label.

Results of two variants can be compared in the chart manager.

Page 4: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Data Management, Interactive Graphics NEPLAN

Network Diagram Coloring

Colors and line types can be freely selected.

Elements overloaded after a load flow or short-circuit-current analysis are color-highlighted.

Isolated elements can be highlighted.

Coloring options to distinguish user-selectable network areas, zones, voltage levels, earthed or not feeded networks and galvanic separated networks.

Differences to the parent variant or the root net can be colored.

Each element can be colored individually.

User defined graphic layers can be colored.

Coloring according to ranges. Many calculated variables can be colored according to their values (e.g. according to element losses or according to voltage drops)

Auxiliary Graphics

Auxiliary graphics can be used for documenting the diagram.

Input of lines, rectangles, ellipses, arcs, ellipse sections, polygons, polylines, any kind of bitmap graphics.

Input of user text with selectable character set.

Color for background, foreground, line, outlines and fill patterns is user-selectable.

Functions available for rendering overlapped symbol elements, rendering, alignment and rotation

Page 5: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

SQL Database Connection

All element data can be imported and exported to any SQL database (like Oracle, MS-Access, etc.)

SQL database includes all network equipment. (HVDC, SVC, STATCOM, TCSC, UPFC, protection devices, etc.).

The network topology can be stored.

Graphic of the elements and nodes can be exported and imported.

All data of all libraries can be imported and exported.

Can be used as interface to existing GIS and NIS or DMS/SCADA systems.

Very flexible storing and import features, like full import or only updating, storing only variant differences, etc.

Partial reading of data fields (e.g. read only the line length but do not read the R and X values)

The database can be simply upgraded to form a NIS using the database functions.

Symbol-Editor

The user can create and define for each element type and node his own symbols.

Any number of different symbols per element type or node can be defined.

All symbols will be displayed while entering the diagram. Just drag and drop the desired symbol to the diagram

On the diagram the symbols can be flipped, rotated and resized.

Data Management, Interactive Graphics NEPLAN

Page 6: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Data Management, Interactive Graphics NEPLAN

Library Manager

The comprehensive library manager is fully integrated.

For each equipment type a library exists or can be created by the user.

While entering network data the data in the library can be accessed. Further more the data entered in the network, can be exported to the library.

All network data can be updated with changed library data.

The data can be entered through excel like table sheets.

Import/export to MS-Excel with drag and drop.

Import/export to any SQL database. Update functionality from/ to database is provided.

Part of diagrams with all technical data can be stored in the library (e.g. used for IEEE control circuits).

Chart Manager

The chart manager allows to display the results in different charts (e.g. line, bar, etc.).

Any number of sub charts can be displayed in one chart.

A user defined logo (as bitmap) can be added to the header for documentation purposes

Results from different variants can be compared and displayed in the same chart.

Export the chart to *.JPG file for any internet browser.

Copy/paste to the clipboard for documentation (e.g. MS-Words).

Page 7: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Data Management, Interactive Graphics NEPLAN

Station Kaisterfeld

Leibstadt

Batiaz

Veytaux Chavalon

La Veyre Vaux

Banlieu

Foretaille

Mathod

Kerzers Galmiz

Hauterive

Botterens

Chandolin

Eysins

Stalden

Bitsch

Moerel

Fiesch

Ulrichen

Gstaad

Innertkirchen

Robiei

Bavona

Iragna

BiascaPeccia

Littau

Wimmis Wattenwil

Cavergno

Avegno

Magadino

GordunoSerra

Ingenbohl

Plattis

Goeschenen

Vallorcine

Ilanz

Rothenbrunnen

Mapragg

Filisur

Montlingen

Moerschwil

Schlattingen

Toess

Wittenwil

Weinfelden

Altgass

SiebnenSamstagern

Thalwil

Wollishofen

Waldegg

Obfelden

Niederwil

Regensdorf

Pradella

Robbia

Seebach

Auwiesen

Faellanden

Aathal

Birr

Rupp

Sursee

Lindenholz

Oftringen

Ormalingen

Lachmatt

Muenchwilen

Flumenthal

Asphard

Gerlafingen Pieterlen

Cornier

Gurtweil

Meiningen

Mese

Pallanzeno

Pressy

Koblenz

Engstlatt

Sierentz

Mambeli

Bois Tollot Piedilago

Musignano

Bulciago

Westtirol

Riet

Sondrio

Ponte

T.Acqua

Valpelline Avise

Austria

Italy

France

Germany

Sierentz

1 2 3

Engstlatt TiengenLeibstadt Gurtweil

AsphardMuenchwilen

BassecourtBickigen

Oftringen220kV 380kVBeznau

220kV 380kV Breite

Lindenholz

A B

Goesgen

Kuehmoos380 kV 220 kV

A B

ZOOM into STATION Kaisterfeld

P=660.9Q=337.3

Ploss=0.8Qloss=67.3Load=74.2

P=660.9Q=337.3

Ploss=0.8Qloss=67.3Load=74.2

P=-660.1Q=-270.0Ploss=0.8

Qloss=67.3Load=71.3

P=-660.1Q=-270.0Ploss=0.8

Qloss=67.3Load=71.3

P=-148.2Q=78.2

Ploss=0.0Qloss=0.0Load=0.0

P=-148.2Q=78.2

Ploss=0.0Qloss=0.0Load=0.0

P=70.9Q=-58.4

Ploss=0.0Qloss=0.0Load=0.0

P=70.9Q=-58.4

Ploss=0.0Qloss=0.0Load=0.0

P=119.0Q=-121.4Ploss=0.0Qloss=0.0Load=0.0

P=119.0Q=-121.4Ploss=0.0Qloss=0.0Load=0.0

P=512.1Q=8.0

Ploss=0.0Qloss=0.0Load=0.0

P=512.1Q=8.0

Ploss=0.0Qloss=0.0Load=0.0

P=-49.0Q=-19.1

Ploss=0.0Qloss=0.0Load=0.0

P=-49.0Q=-19.1

Ploss=0.0Qloss=0.0Load=0.0

P=9.6Q=10.7

Ploss=0.0Qloss=0.0Load=0.0

P=9.6Q=10.7

Ploss=0.0Qloss=0.0Load=0.0

P=11.4Q=13.3

Ploss=0.0Qloss=0.0Load=0.0

P=11.4Q=13.3

Ploss=0.0Qloss=0.0Load=0.0

P=172.8Q=85.3

Ploss=0.0Qloss=0.0Load=0.0

P=172.8Q=85.3

Ploss=0.0Qloss=0.0Load=0.0

P=37.2Q=12.8

Ploss=0.0Qloss=0.0Load=0.0

P=37.2Q=12.8

Ploss=0.0Qloss=0.0Load=0.0

P=242.1Q=74.1

Ploss=0.0Qloss=0.0Load=0.0

P=242.1Q=74.1

Ploss=0.0Qloss=0.0Load=0.0

P=242.4Q=74.1

Ploss=0.0Qloss=0.0Load=0.0

P=242.4Q=74.1

Ploss=0.0Qloss=0.0Load=0.0

P=-105.3Q=2.3

Ploss=0.0Qloss=0.0Load=0.0

P=-105.3Q=2.3

Ploss=0.0Qloss=0.0Load=0.0

P=-660.1Q=-270.0Ploss=0.0Qloss=0.0Load=0.0

P=-660.1Q=-270.0Ploss=0.0Qloss=0.0Load=0.0

P=660.9Q=337.3

Ploss=0.0Qloss=0.0Load=0.0

P=660.9Q=337.3

Ploss=0.0Qloss=0.0Load=0.0

LAUFENB2 RU=243.353

LAUFENB2 RU=243.353

LAUFENB-TRAFO2U=243.353

LAUFENB-TRAFO2U=243.353

LAUFENB2 BU=240.435

LAUFENB2 BU=240.435

LAUFENB3 RU=414.144

LAUFENB3 RU=414.144

LAUFENB-TRAFO3U=406.600

LAUFENB-TRAFO3U=406.600

LAUFENB3 BU=406.600

LAUFENB3 BU=406.600

Page 8: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Data Management, Interactive Graphics NEPLAN

Constant

3

Constant

3

Inp

ut

P2

Inp

ut

P1

Inv

erte

r

Vd

/dt*C

)

Source

Vsref

Input

Vs

So

urc

e

- fahra

d

Source

Ub

Output

delta 1

Source

ted (kV)

Source

Ub

Inverter

1

Co

nstan

t

Sb

-> C

CS

Source

kA->A

Source

Rt1

Source

Rt2

So

urc

e

Rt1

So

urc

e

Rt2

Source

(Mvar)

Input

Qline

Input

Pline

Source

f (MW)

Source

f(Mvar)

Source

Xt2

Source

Ub

Source

(Mvar)

Input

I1

Power

2

Constant

A ->kA

Input

I2

Power

2

Constant

A -> kA

SG

SG

Output

delta Vpq

Constant

Rad->Deg

Input

Im (I1)

So

urc

e 3

Constant

A -> kA

Co

ns

tan

t

1/S

b

Po

we

r

0.5

Input

nerator Vd

Input

Delta Q

Input

Delta P

SG

Constant

Rad->Deg

Polar

> Pol (CCS)

So

urc

e

Ub

Source

sqrt(3)

So

urc

e 2

Integrator

Integral

Source

Vdc init

Power

2

Power

d=sqrt(U)

Source

Vd ref

Limit1

Vd limit

Output

Vpq

Limit1

Vpq limiter

Output

I1

Limit1

I1 limit

Source

180

Constant

Slope

Source

0

Constant

2Constant

MW->pu

Constant

ar -> pu

Polar

Rec->Pol

Integrator

Vd I-Ctrl

Constant

u (1/22)

Constant

Constant

Input

delta4

So

urc

e

H3

(s)

So

urc

e

H4

(s)

Inv

erter

1/x

Inv

erte

r

1/x

So

urc

e

H1

(s)

So

urc

e

H2

(s)

SIN

sin DELTA

So

urc

e

Ks

h

Input

w3

Constant

Hz -> pu

Input

w4

Constant

Hz -> pu

Constant

eg -> Rad

Constant

eg -> Rad

Input

delta3

Input

delta1

Constant

eg -> Rad

Constant

eg -> Rad

Input

delta2

Input

w1

Constant

Hz -> pu

Constant

Hz -> pu

Input

w2

LAG

Vd lag

LAG

Vs lag

COS

os DELTA

Source

K2

Source

K1

LAG

P smooth

LAG

Q smooth

Integrator

P I-Ctrl

Constant

Constant

Integrator

Q I-Ctrl

Constant

Constant

Constant

Constant

Integrator

Vs I-Ctrl

TR1

P=6.12Q=-4.70

Ploss=0.00Qloss=-5.76

P=-6.12Q=-1.06

Ploss=0.00Qloss=-5.76

TR1

P=6.12Q=-4.70

Ploss=0.00Qloss=-5.76

P=-6.12Q=-1.06

Ploss=0.00Qloss=-5.76

TR2

P=-4.50Q=-5.74

Ploss=0.00Qloss=-5.76

P=4.50Q=-0.02

Ploss=0.00Qloss=-5.76TR2

P=-4.50Q=-5.74

Ploss=0.00Qloss=-5.76

P=4.50Q=-0.02

Ploss=0.00Qloss=-5.76

K6U=220.095

K6U=220.095

K3U=219.794

K3U=219.794

EL30

P=21.66Q=-6.96

Ploss=0.04Qloss=-5.58

P=-21.62Q=1.38

Ploss=0.04Qloss=-5.58

EL30

P=21.66Q=-6.96

Ploss=0.04Qloss=-5.58

P=-21.62Q=1.38

Ploss=0.04Qloss=-5.58

K4U=219.986

K4U=219.986

EL29

P=-30.00Q=4.15

Ploss=0.00Qloss=-5.40

P=30.00Q=-9.55

Ploss=0.00Qloss=-5.40

EL29

P=-30.00Q=4.15

Ploss=0.00Qloss=-5.40

P=30.00Q=-9.55

Ploss=0.00Qloss=-5.40

K1U=220

K1U=220

K12U=220.622

K12U=220.622

EL28

P=-18.38Q=-0.60

Ploss=0.03Qloss=-5.64

P=18.41Q=-5.04

Ploss=0.03Qloss=-5.64

EL28

P=-18.38Q=-0.60

Ploss=0.03Qloss=-5.64

P=18.41Q=-5.04

Ploss=0.03Qloss=-5.64 K

U=2K

U=2

KU=220

KU=220

ONE

TWO

FOUR

THREE

ZONES

Page 9: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Data Management, Interactive Graphics NEPLAN

Page 10: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

EL1

P=98.2Q=-17.7

Load=0.0

P=-98.0Q=19.9

Load=0.0

EL1

P=98.2Q=-17.7

Load=0.0

P=-98.0Q=19.9

Load=0.0

EL2P=48.0Q=-29.9

Load=0.0

P=-48.0Q=30.3

Load=0.0EL2

P=48.0Q=-29.9

Load=0.0

P=-48.0Q=30.3

Load=0.0

EL3 P=-102.0Q=-70.3

Load=0.0

P=102.2Q=72.0

Load=0.0 EL3 P=-102.0Q=-70.3

Load=0.0

P=102.2Q=72.0

Load=0.0

EL4

P=-102.2Q=-72.0

Load=0.0

P=102.5Q=75.3

Load=0.0

EL4

P=-102.2Q=-72.0

Load=0.0

P=102.5Q=75.3

Load=0.0

EL5

P=200.4Q=33.8

Load=0.0

P=-200.0Q=-29.5

Load=0.0

EL5

P=200.4Q=33.8

Load=0.0

P=-200.0Q=-29.5

Load=0.0

EL6

P=200.0Q=50.0

Load=0.0

P=-198.2Q=-32.3

Load=0.0EL6

P=200.0Q=50.0

Load=0.0

P=-198.2Q=-32.3

Load=0.0

P=0.0Q=0.0

Load=0.0

P=0.0Q=0.0

Load=0.0

EL7P=-303.0Q=-109.1

EL7P=-303.0Q=-109.1

EL8P=100.0Q=50.0

EL8P=100.0Q=50.0

EL9P=50.0Q=10.0

EL9P=50.0Q=10.0

EL10P=150.0Q=40.0

EL10P=150.0Q=40.0

K7U=216.155

u=98.3Uang=-1.145

K7U=216.155

u=98.3Uang=-1.145

K1U=220.000

u=100.0Uang=0.000

K1U=220.000

u=100.0Uang=0.000

K4U=213.251

u=96.9Uang=-0.156

K4U=213.251

u=96.9Uang=-0.156

K5U=213.674

u=97.1Uang=-1.413

K5U=213.674

u=97.1Uang=-1.413

K6U=214.265

u=97.4Uang=-1.732

K6U=214.265

u=97.4Uang=-1.732

P=0.0Q=0.0

Load=0.0

P=0.0Q=0.0

Load=0.0

P=0.0Q=0.0

Load=0.0

P=0.0Q=0.0

Load=0.0EL11EL11

P=200.0Q=29.5

Load=0.0

P=200.0Q=29.5

Load=0.0

K2U=218.823

u=99.5Uang=-1.173

K2U=218.823

u=99.5Uang=-1.173

P=-200.0Q=-50.0

Load=0.0

P=-200.0Q=-50.0

Load=0.0

UPFC-9541UT=22.182

PhiT=91.531IQ=0.01Px=-4.0

QxSer=20.5Q Sh 0 0

UPFC-9541UT=22.182

PhiT=91.531IQ=0.01Px=-4.0

QxSer=20.5Q Sh 0 0

P=0.0Q=0.0

Load=0.0

P=0.0Q=0.0

Load=0.0

K3U=218.901

u=99.5Uang=4.637

K3U=218.901

u=99.5Uang=4.637

P=0.0Q=0.0

Load=0.0

P=0.0Q=0.0

Load=0.0

SER-RLC-158SER-RLC-158 TCSC-9577TCSC-9577

UPFC Active:Regulate P to 200 MW and Q to 50 MVar

Data Management, Interactive Graphics NEPLAN

I=0.540 kALoad=135.4 %

Ik"(L1)=0.000 kA

I=0.540 kALoad=135.4 %

Ik"(L1)=0.000 kA

I=0.097 kALoad=52.3 %

Ik"(L1)=13.153 kA

I=0.097 kALoad=52.3 %

Ik"(L1)=13.153 kA

I=0.023 kALoad=11.1 %

Ik"(L1)=0.263 kA

I=0.023 kALoad=11.1 %

Ik"(L1)=0.263 kA

I=1.160 kALoad=123.1 %

Ik"(L1)=13.153 kA

I=1.160 kALoad=123.1 %

Ik"(L1)=13.153 kA

Ik"(L1)=0.263 kAIk"(L1)=0.263 kA

Ik"(L1)=0.926 kAIk"(L1)=0.926 kA

toff=2.00 stoff=2.00 s

toff=0.01 stoff=0.01 s

t-lf=42.48 stoff=0.15 st-lf=42.48 stoff=0.15 s

t-lf=56.98 st-lf=56.98 s

MEDIUM-VOLTAGEMEDIUM-VOLTAGE

MOTORIk"(L1)=14.013 kA

MOTORIk"(L1)=14.013 kA

LOW-VOLTAGELOW-VOLTAGE

DISTRIBUTIONDISTRIBUTION

Page 11: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Load Flow Analysis NEPLAN

Computation procedures: Current Iteration, Newton Raphson, Extended Newton Raphson, Voltage Drop

Limit check and appropriate automatic conversion of the node type. Voltage and flow control with phase-shifting transformers, controllable three windings transformers. FACTS devices: SVC, STATCOM, TCSC, UPFC Node types: slack, PQ, PV, PC, SC, PI, IC. More than one slack node possible. Power interchange between area / zones (area interchange control). Asymmetrical network elements and loads

Predefined and user defined scaling factors for fast load and generation variations

Distributed slack node

Load balancing

Calculation of loss sensitivities

Step length convergence control

Initialization file input / output

Page 12: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Load Flow Analysis NEPLAN

Results Automatic output of results. ’Move’ and ’Delete’ function for result boxes. Placeholders are saved. Self-defined result output: the user can select items, units, font, precision, placement Overloaded elements or nodes with voltages outside predefined limits are highlighted. Line thickness corresponds to element loading. Results can be saved in a text file (ASCII) Table output: for the whole network, individually for each area / zone. Listing of power flows

between area/zones, overloaded elements, sorting function, selective output. Table interface with MS-Excel

Page 13: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Short Circuit Analysis NEPLAN

Computations: IEC 909/VDE 0102, ANSI/IEEE, IEC 60909, superposition method

Consideration of prefault voltages from a load flow computation.

Computation of single-, two- (with and without earth connection) and three-phase faults.

Option for computing user-defined fault types (e.g. double earth fault, fault between two voltage levels).

Library with special faults is available (can be extended by user).

Option for computing line faults (fault location on line user-selectable).

Computable fault current types: initial symmetrical short-circuit current and power, peak, breaking, sustained short-circuit current, thermal and asymmetrical breaking current, plus DC component.

Computation of minimum/maximum short-circuit current.

Precise model for transformer earthing connection.

Asymmetrical network structure are allowed for (asymmetrical short circuit)

Current limiting due to circuit breakers Line Coupling Mutual impedances and capacitances in the

positive and negative-sequence systems are allowed for in short-circuit current computation.

Circuit and coupling parameters of the overhead lines are computed from the conductor configuration.

Overhead lines with up to 6-phase systems and 3 earth wires can be computed.

Bundled conductors are allowed for. Unrestricted number of overhead lines can be

entered. Parameters and conductor configuration are saved

in an SQL database.

Page 14: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Short Circuit Analysis NEPLAN

Results Automatic entry of results. Move and delete function for result boxes. Placeholders are saved. Self-defined result output in regard to units, formats and fault current types. Results can be inserted either at the beginning and/or end node, or also in the element's center. In the event of a short-circuit, all overloaded pieces of equipment (current transformers, voltage

transformers, circuit-breakers, etc.) are highlighted. Results can be saved in a result file (ASCII file) and in an SQL database. Result lists can be saved in text files. List output: sorted by voltage levels. Short-circuit impedance and all computable fault currents are

output as phase values or as symmetrical components.

Page 15: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Transient Stability NEPLAN

General features Dynamic models for synchronous machines, asynchronous machines, loads, power electronic devices

(SVC, UPFC, TCSC, STATCOM), HVDC systems, protection devices, control circuits

Graphical input of control circuits with predefined function blocks.

Various synchronous machine models: classic, transient, subtransient; saturation of d- and q-axis considered.

Extensive event report, monitoring any variable on the screen.

Case handling is very easy.

Definition of all kind of disturbances.

Control Circuits Any control circuit (AVR, GOV, SVC, etc.) may be built freely by basic function blocks. More than 50 basic function blocks are available. User friendly editing facilities. Select function blocks from a list, drag into position by mouse,

connect with one another by lines. Import/export facilities for control circuits between the editor and libraries. Storage of control circuits, such as, exciter, regulator, PS-stabilizer, V-transducer etc., separately in

the Library. Concatenation of control circuits.

Page 16: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Transient Stability NEPLAN

Protection Devices Min-max-relays (overcurrent, undervoltage,

frequency,...): modeled with up to 4 tripping stages. E.g. various load shedding schemes may be simulated.

Fuses

Pole slip relays, model includes binary input signals from external sources

Distance protection: pick-up and tripping stages, impedance diagrams, binary input signals from external sources.

Disturbances Generation and storage of various disturbance cases. Each disturbance case may have more than one event. Definition of faults (symmetrical and unsymmetrical) on buses, bus elements, branches. Loss of generator excitation Different switching operations (feed-forward control in control circuits, cross coupling of protective devices,

in/out of branches, etc.). Transformer tap modification. Load shedding scenarios (also in relation to frequency relay). Disturbances with function generators (step, ramp, sinusoidal function or combination). Start-up of motors with different start-up devices.

Page 17: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Small Signal Stability NEPLAN

The NEPLAN Small Signal Stability module provides eigenvalue analysis (modal analysis) for electrical power systems. It combines exceptional ease of use with the latest techniques and standards in both electrical power engineering and software design. Like the other modules, Small Signal Stability is a seamless module within NEPLAN.

Applications Analysis of interarea oscillations

Analysis of interplant oscillation

Identification of groups and subgroups of machines swinging against each other

Determination and improvement of power oscillation damping

Design and placement of control equipment, such as power system stabilizers

Page 18: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Main Features Automatic construction of the linearized state space notation for the complete system, including

generators, static loads, control circuits, etc.

Advanced synchronous machine modeling: choose for every synchronous machine one of the five models infinite, classical, transient, subtransient and general. Saturation curves for both, d-axis and q-axis.

Automatic calculation of eigenvalues, eigenvectors, mode shapes, participation factors for eigenvalues and state variables.

Text results: results are presented in clear form and can be customized by several output options.

Graphical results: results can be visualized by the fully integrated graphical results manager. Charts can be easily printed and exported to external programs (e.g. Microsoft Word) by clipboard functions. A variety of chart options is available.

The only requirement is the NEPLAN load flow module. However, the Small Signal Stability and the Transient Stability (time simulation) module of NEPLAN complement each other ideally.

The Small Signal Stability module is completely integrated in NEPLAN and uses standard dynamic element data (like the Transient Stability module).

Small Signal Stability NEPLAN

Page 19: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

As an integral part of NEPLAN software, the Voltage Stability module provides 4 approaches for static voltage stability analysis of power systems: V-Q curves, P-V curves, V-Q sensitivity analysis and Q-V eigenvalue analysis (modal analysis). This module allows examination of a wide range of system conditions. It is an ideal tool to provide much insight into the nature of voltage stability problems.

Applications Identification of weak / not controllable / unstable areas

Identification of weak and heavily loaded links

Proper distribution of reactive reserves in order to maintain an adequate voltage stability margin

Voltage sensitivity information

Degree of voltage stability

Most effective measures in improving voltage stability

Voltage Stability Analysis NEPLAN

Page 20: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Main Features Automatic calculation of P-V curves, V-Q curves, dV/dQ self-sensitivities, dV/dQ mutual sensitivities,

eigenvalues, eigenvectors, bus participation factors, branch participation factors and generator participation factors.

Result tables: results are presented in clear form and can be exported by Copy-Paste-methods to external programs (e.g. MS-Excel).

Graphical results: results can be visualized by the fully integrated graphical results manager.

Export files: results are stored in text files for advanced data export.

Charts can be easily printed and exported to external programs (e.g. MS-Word) by clipboard functions. A variety of chart options is available.

Input: standard load flow input data

Voltage Stability Analysis NEPLAN

Page 21: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Harmonic Analysis NEPLAN

Module is fully integrated, and works independently of the type and size of the network concerned.

Planning of ripple control systems, dimensioning of compensators (SVC) and harmonic filters, plus determination of network impedance for subsynchronous resonances.

Option for simulating frequency response of intermeshed networks.

Harmonic generators (current and voltage sources) are entered directly in the single line diagram. Libraries available.

Unrestricted number of harmonic generators can be computed with each harmonic.

Computation of network impedance, and the harmonic level for each frequency and for each node.

Frequency-dependence of elements is allowed for.

Libraries for frequency-dependence are available (can be extended by the user).

Length of computation steps for impedance computation is automatically adjusted to resonance proximity.

Harmonic load flow

Harmonic Levels Current and voltage computation at all frequencies

and at all predefined nodes and elements. Computation of r.m.s. values for harmonic voltages

and Currents. Computation of total harmonic voltage factor in

conformity with DIN/IEC and distortion factor in accordance with IEEE.

Computation of telephone parameters (TIF, IT, KVT).

Comparison of computed harmonic levels with the limit values laid down in VDE 0160/5.88 or with any other standards desired.

List output of ripple control currents and voltages at any desired frequencies and at each node and each element.

Automatic entry of results in the single line diagram. Harmonic sum calculation: vectorial, geometric,

arithemtic, acc. to IEC 1000-2-6

Page 22: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Harmonic Analysis NEPLAN

Filter Dimensioning Filter elements are transferred directly into the

single line diagram. Filter elements: filters (normal, HP, C-filter),

series RLC-circuits with or without earth connection, ripple control traps.

Filters are dimensioned directly by the program.

Filter data are listed or saved in a text file. Result lists can be saved in text files. Results can be saved in result files for

evaluation by means of spreadsheet programs (like MS-Excel).

Page 23: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

All types of protective devices with an overcurrent-time characteristic can be entered: fusegear, circuit-breakers, definite-time overcurrent relays and inverse-time relays, electronic relays.

Up to 6 protective functions (blocking of directional and non-directional overcurrent protection) can be assigned to each protective device.

Extensive libraries with protective devices from a variety of manufacturers are available, and can be extended at will.

Option for entering user-defined characteristics for simulating motor start-ups or thermal loadability of conductors, transformers, etc.

Characteristic can be shifted using a k-factor (inverse-time relay). Entry options for characteristics: point-by-point or formula in conformity with BS142 or the American ASA

standard.

Overcurrent Protection NEPLAN

Page 24: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Overcurrent Protection NEPLAN

Selectivity Diagram Relays and current transformers are positioned in the network plan graphically. Transformation ratios of current transformers incorporated in the network plan are allowed for in the

selectivity diagrams. A maximum of 6 characteristics can be incorporated in one diagram. Unrestricted number of diagrams can be processed simultaneously. Selectivity analysis over more than one voltage level, and independently of the network type and size

involved. Two reference voltages for diagrams can be user-defined. Individualized coloring of the characteristics. No limit on number of diagrams and protective numbers for management.

Transferring Current Values Direct connection from short-circuit current and load flow module for

transferring the currents.

Up to 6 currents can be transferred into one diagram.

Import/export functions.

Page 25: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Network Reduction NEPLAN

This module is designed to reduce the size of a network model by replacing sets of buses and the network elements (lines, transformers,...) that connect them with a smaller but exact, numerically equivalent network. For a properly chosen set of buses, this equivalent network will have fewer buses and branches than the original, yet still provide the correct response to faults or load flow calculations in the unreduced portion.

The network can be reduced for symmetrical or asymmetrical short circuit calculations according to IEC909, IEC60909, ANSI/IEEE or

superposition method and load flow calculation.

The reduced network gives the same short circuit or load flow results as the original network. Giving the nodes to be reduced, the program determines the boundary nodes automatically.

Page 26: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Network Reduction NEPLAN

Input

any network as for short circuit or load flow calculation nodes to be reduced during network reduction functions to select a complete network area to be reduced are available boundary nodes are determined automatically by the program

Output

shunt and series equivalents, which can be saved in the data base the shunt and series equivalents consists of data for the positive, negative and zero system

dependent on the type of network reduction (load flow or short circuit) for load flow network reduction boundary injections and boundary generators are calculated

Page 27: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Optimal Power Flow NEPLAN

Control variables: active / reactive power generation, schedule voltages of generators and ULTC-transformers, reference values of HVDC systems and FACTS (UPFC, STATCOM, SVC, TCSC,...)

Variable limits for bus voltages, branch loadings, active and reactive power of generators Individual or general limits, ’consider/not consider’ limits function Objective function: apply to whole network / to a certain area or zone, minimize / maximize MW losses,

Mvar losses, generation costs, MW import or Mvar import Multi objective function is possible (use of weight factors)

Page 28: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Optimal Power Flow NEPLAN

Results Automatic output of results. ’Move’ and ’Delete’ function for result boxes. Placeholders are saved. Self-defined result output: the user can select items, units, font, precision, placement Overloaded elements or nodes with voltages outside predefined limits are highlighted. Line thickness corresponds to element loading. Results can be saved in a text file (ASCII) Table output: for the whole network, individually for each area / zone. Listing of power flows between

area/zones, overloaded elements, sorting function, selective output. Table interface with MS-Excel

Page 29: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Motor Starting AnalysisDynamic Simulation NEPLAN

Motor Starting Computation Simulation of motor start-up in unlimited

networks.

Simultaneous or time-delayed start-up for any desired number of motors.

Identification of motor parameters using the least square of error method.

Different motor models, depending on the motor data entered.

Saturation and eddy-current losses in the motor allowed for (linear or point-by-point).

Libraries for standard motor data, plus additional libraries for Me(s), I(s) and cosj(s) are available (can be extended by the user).

Operating point computation for all non-starting motors in accordance with their load characteristics (Newton-Raphson).

Automatic tap changing transformers are allowed for after a user-defined time-delay.

Load torque entered as a characteristic or as a linear or quadratic load torque curve.

Libraries for load torques are available (can be extended by the user).

Start-up devices are allowed for, such as star-delta starter, series resistor, transformer.

Voltage Drop Computation of voltage drop to the

moment t = 0. Reduced data entry for motors and

computation parameters. Non-starting motors can be simulated

by a user-defined load PQ (constant power) or shunt.

Overloaded elements, measuring instruments and protective devices or nodes with voltages outside a defined range are highlighted.

Results of the voltage drop computation are displayed in the single line diagram.

The motor data entered and the motor parameters computed can be accessed by clicking on the motor concerned in the single line diagram.

Page 30: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Results Computation of voltage U(t) at predefined nodes.

Computation l(t), P(t), Q(t) for each predefined element.

Computation of motor current I, load torque M, electromagnetic torque Me, active power P and reactive power Q as functions of time, or of the slip for starting-up and non-starting-up motors.

Graphical output of the characteristic curves and time characteristics, with automatic scaling of the axes.

Dimensioning and colors can be altered.

Result lists can be saved in text files.

Results can be saved in result files for evaluation by means of spreadsheet programs (such as MS-Excel).

Motor Starting AnalysisDynamic Simulation NEPLAN

Page 31: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Load Flow with Load Profiles NEPLAN

Input Data

User-defined load and generation profiles (day, week, month and year factors)

Unlimited number of profile types for consumers and generators (e.g. household, industry, ...)

Import of measurement data and behaviors of power factors

Calculations

Single load flow calculation (load forecast) and time simulation

User-defined time increment

Combination of time intervals

Load balancing mode: loads are automatically changed in the way that load flow results fit best to measured values (behaviors)

Page 32: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Results

Time behavior and value range charts

Characteristics of network, elements and nodes (voltages, currents, loadings, power, MW losses, energy losses,…)

Any system quantities may be plotted, or compared

Load Flow with Load Profiles NEPLAN

Page 33: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Wind Power Applications NEPLAN

Steady State and Dynamic Simulation

Generator models Asynchronous machine

Double fed asynchronous machine

Synchronous machine

Calculation modules Load flow

Short circuit

Transient stability

Voltage stability

Over current protection Harmonic analysis

Typical applications Verification of connection conditions

Steady state and dynamic simulation of whole wind parks

Determination of optimal connections in regard of technical and economical aspects

Increase of short circuit currents

SC capacity of cables and equipment

Protection settings

Reactive power compensation

Harmonics level calculations

Functions to represent different wind conditions Pitch control representation

Tower and blades mechanism Stability aspects in power system and wind park

Page 34: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Probabilistic Reliability Analysis Determining the frequency, average duration and cost of network component failures, leading to voltage sags and supply interruptions. Consideration of

Outage behavior (failure rate and repair times) of network equipment

Network operation in normal state and for multiple order network contingencies

Admissible short-time component overloadings

Protection concept including protection failures

Realistic generation patterns and load curves

Reliability Analysis is imperative for

Optimum asset allocation and cost-benefit analysis for investments in transmission and distribution networks

Design and evaluation of innovative substation layouts

Weak-point analysis in existing networks

Design of automation concepts in public and industrial distribution networks

Detailed and objective discussion of network connection concepts for high-demand customers and power plants

Cost-effective mitigation of power quality problems (voltage sags)

Add-on for NEPLAN-Main – a tool to apply Reliability Centered Maintenance (RCM) Strategy, which leads to substantial reduction of maintenance expenses

Reliability Analysis NEPLAN

Page 35: Neplan_E.pdf

ABB AG Kallstadter Strasse 1 Phone +49 621 381 5122 www.abb.de/neplan, [email protected] D-68309 Mannheim Fax +49 621 381 2753

ABB

Procedure of Reliability Analysis Relevant component failures

Single order contingencies:

Stochastic failures

Common-Mode failures

Spontaneous protection tripping

Second order contingencies:

Overlapping independent stochastic outages

Failure occurring during the maintenance of the backup components

Protection failure or overfunction

Multiple earth-faults

Calculated results

Frequency of supply interruptions fd in #/yr

Probability of supply interruptions qd in min/yr

Mean interruption durations Td in hrs

Energy not served in time Wd in MWh/yr

Interruption cost Cd in $/yr

Presentation of results

Result values printed at load nodes in network plan

Color shading of the network graph in dependence of the reliability results

Various filter functions implemented for detailed analysis

Integrated flexible diagram functions to visualize the calculation results

Results fully exportable for use in tables and diagrams

Evaluation functions

Consideration of power/energy-specific interruption cost

Filter to investigate component contributions to load node interruptions

Copying of diagrams into clipboard

Shading of network diagram in dependence of load node results

Analysis of system reaction after faults