Technical Guidance
Morse Taper
External Hex
Internal Hex
Transgingival
Zygomatic
Surgical Techniques
Instrumental
Surgical Instruments
Orthodontic Anchorage and Bone Grafting
2
Neodent is much more than dental implants .
It’s a company made for you.
3
earea100%Braziliancompanywithover16yearsofhistory,focusedessentiallyonourclients.Wehaveasmaincharacteristictoprovidesolutionswithhightechnologyandassuredquality.Operatinginfivecontinents,weareproudtobeoneofthebiggestmanufacturersofdentalimplantsandprostheticcomponentsintheworld.
LeaderinBrazil,wehavethesatisfactionofourclientsasourmainobjective.Therefore,wearecommitedtoworkwithseriousnessanddedicationtoofferyoumuchmorethandentalimplants.Thisyoualreadyknow.Whatmaybeyoudon´tknowisthat"muchmore"impliesinaggregatevaluesandqualitiesthatactdirectlywithyourwork.“Muchmore”wastheresultofour
commitmenttoresearchanddevelopmentofnewtechnologies,whichalliedwithsustainability,resultsinamodernindustrialcomplexwhichisenvironmentallycorrect.The“muchmore”ispresentfromourtechnicalsupport,preparedtoanswerwithexcellence,evenincriticalsituations.Wewanttoalwaysbemuchmore,sothatyoualsocontinuebeingso.
W
4
To guarantee our innovative potential and high technology, we inaugurated in 2009 the New Industrial
Complex with 12.000 m² in one plot of 50.000m², expanding the production potential like no other
one in Latin America. The entire project was thought up so that the structure could transmit our values:
advances in technology, respect for human beings and socio-environmental responsibility.
Besides being able to count upon the best
and most modern robotic equipment, the New
Industrial Complex hosted a complete materials
laboratory: The Integrated Laboratory of Materials
– LIM, aimed directly at research, development
and quality control. In LIM, we have the Scanning
Electron Microscope (MEV), which assures
quality from the raw-material through to the end
product. The equipments for mechanical and
metallographic tests assess long-term resistance
and enable the microstructural analysis of
products. All of this is reflected in excellence for
you, client who trusts and takes our name into
your consulting room.
Continuous Development and Quality Control
The industry
PRODUCTION
QUALITY CONTROL
5
SA
LA L
IMPA
SCANNING ELECTRONIC MICROSCOPE
CYCLIC MECHANICAL TESTS
CLEAN ROOM
6
The respect to human standards is a principle trait in the architectural design of the New Industrial Complex,
highlighted by the preference for naturally lit environment and of the use of materials and technologies that
provide greater thermoacoustic comfort. Now, our employees have much more infrastructure and ergonomy
for their daily activities. We also have a fully-equipped restaurant visually integrated into the grove, which
attends to the necessities of the employees and visitors, including during the diverse events promoted.
Concerned with constant trainning, we constructed a spacious auditorium to promote the transmission of
knowledge, one of the important pillars of our essence. Besides intellectual development, encouragement
towards sport is also a priority: sport courts, a golf course, football and wood forest for hiking. These values
are the base of a strong trademark that focuses on the people and works for their wellbeing.
Respect to human standards
SPORT COURTS
AU
DIT
OR
IUM
: C
ON
STA
NT
PR
OFE
SIO
NA
L TR
AIN
ING
RESTAURANT
7
We work with socio-environmental responsibility, respecting
the ideal conditions for growth without harming the planet,
and evoking the same consciousness in the whole team of
employees and partners.
Environment
LIQUID TREATMENT STATION
PREFERENCE FOR NATURAL LIGHT
8
We count on the scientific support of ILAPEO – The Latin American Institute of Research
and Dental Education - , a centre of excellence in research, advances and innovations
in the clinical practice of dentistry. An institute made up of professionals, professors
and researchers of the highest level of knowledge who offer post-graduate
courses, such as specialisation and master’s degree, recognised by CFO, MEC
and CAPES.
AUDITORIUM
MULTIDISCIPLINARY LABORATORY
BLUE CLINIC RECEPTION
9
•RDC 59/2000 – ANVISA - Certificate of Good Practices in the Manufacture and Control of Health
Products;
•ISO 13485 – Health Products – Systems Quality Management – Requisites for regulatory
purposes;
•CE MARK – European Directive 93/42 CEE – Relative to the Medical Devices;
•ISO 9001 – Systems Quality Management.
Certificates Quality certificates
Thelargestcompanyinthe
Brazilianmarket,andoneofthe
biggestintheworldmarket,now
operatinginU.S.A.
COMMERCIAL HEADQUARTERS
As well as industrial and commercial headquarters in Curitiba (PR) state
of Paraná,Brazil, we also have ten branches in São Paulo (capital),
Bauru, Rio de Janeiro, Belo Horizonte, Porto Alegre, Goiânia,
Brasília, Londrina, Recife and Vitória. Eight authorised
distributers installed in seven states (Amazonas, Bahia,
Mato Grosso, Mato Grosso do Sul, Pará, Santa
Catarina and Tocantins), as well as branches in
Lisbon, Portugal and U.S.A. An international
network is spread across more than
13 countries: Argentina, Bolivia, Chile,
Colombia, Spain, Italy, Lebanon, Morocco,
Peru, Dominican Republic, Taiwan,
Thailand and Venezuela.
Contact Always here for your needs, you can
count on our channels of communication:
•SAC 08007072526
•Ombuds 08007256363
•www.neodent.com.br
•www.neodentusa.com
A global company
10
NE
OS
HA
PE
1.Pacient
2.Scanning
3.CADmouldingin3Dplanning
software
4.CustomizedpiecefabricationinNEODENTMilling
Center
5.Endoftheprosthesis
withporcelainapplication
•Single or multiple Copings;
•Infrastructures of fixed prosthesis;
•Infrastructures of hybrid prosthesis (protocol);
•Customized Abutments;
•Acrylic Infrastructures.
•Micrometric adaption;
•Optimization of production time;
•3D Virtual 3D waxing;
•Laser Technology - Precision and
quickness in scanning.
AvailableNeoshapeSystemProducts: Differentials:
The Neoshape CAD/CAM System allows the choice of diverse materials with an
emphasis on Zirconia, Cobalt Chromium, Titanium and Acrylic.
Welcome to the technological innovations that now present themselves to the world of prosthesis. Neodent has
the pride and pleasure to announce the Neoshape CAD CAM System. A system that combines new market trends
to guarantee precision and quality in the production of the existing prostheses. This breakthrough opens new
horizons, offering excellence in personalised aesthetics and planning with digital precision.
CAD CAM SYSTEM
11
HowtheNeoshapeCAD/CAMSystemworks:
TheMillingCenter
The dental prosthesis technician (DPT) can plan on
the computer screen in three-dimensional shape
all aesthetic and functional details of differents
prosthetic resolutions in day-to-day laboratorial.
After the virtual waxing conclusion, a computer file is
sent to the Neodent Milling Center. The information
management is carried out on every received case;
then, the file is forwarded to manufacture, where
the latest equipment, dedicated exclusively to the
Neoshape System, produces the received cases with
precision and quality guarantee.
There is where the waxing stops being virtual and
becomes real, adding up Neodent technology to the
professional knowledge and patient biotype, making
smiles more natural and beautiful.
The Neoshape System offers a large library of
prosthetic interfaces jointly with its 3D modeling
software.
The fabrication process starts with the receiving of
the 3D archive, already projected by the prothesis
technician, using the CAD modeling software (virtual
waxing).
Then, the CAM software defines the best strategy for
the production of the received file, taking into account
the dimensions and the particularities of each case, in
order to get the result exactly as the same projected by
a professional.
The latest technology machines execute the milling in
an efficient way and with high precision, making the
fabrication possible from the single copings through to
complete arches.
The exquisite finishing of the margin lines, edges and
the adaption of the copings and customized abutments
with the help of Neoshape system are insurmountable.
Amongstthem:
•Rotational External Hex;
•Anti-rotational External Hex;
•Mini Conical Abutment;
•Universal Post;
Also, there is a available option: the metallic
interfaces, cemented to the personalised abutments,
so that the contact of the implant is obtained
through metal with metal.
•Anti-rotational External Hex;
•Internal Hex.
Once all the fabrication procedures are
concluded, the products are sent directly to the
professionals, who now has more time to
carry out the perfect layering of
the porcelain, ensuring
quality and aesthetics
in their work.
Independent from the chosen material for
the prosthesis construction, the mechanical
properties and the quality guarantee are ensured
by international raw materials of controlled origin,
reinforcing our ethical commitment and offering
you products with excellence.
CA
D C
AM
SYS
TEM
12
Ne
oP
oro
s
Following years of intense research and development
of new technologies, Neodent has achieved the
most modern and current techniques for the surface
treatment of implants: the Neoporos Surface.
Based on the abrasive blasting concept followed by
acid subtraction, the Neoporos Surface promotes, from
on the use of oxides with controlled granulometry,
irregular craters on the implant surface, which are then
standardized by the acid subtraction technique.
The surface uniformity is obtained during the abrasive
blasting and is assured by virtue of the speed robotised
control, pressure and particle size that collide with the
implant.
Various scientific studies are still under way, so that the
Neoporos surface is always evolving and promoting
much more security for you
Electronic microscopes of the
Neoporos Surface in amplifications of 2000X and 5000X.
Roughness controlled to guarantee the size of the pores between
2.5 and 5.0μm in the entire implant
surface.
SurfaceConstantevolutionandsecurityguarantee
13
Histological study of the bone tissue response of
Neodent implants with Neoporos Surface.
Bone crest formed over a cervical portion of the Morse taper implants with Neoporos surface
after a period of osseointegration.
Direct contact of the bone to the implant, showing osteogenesis by contact and the osseous induction potential of Neoporos Surface.
Surface
14
T e c h n i c a l G u i d a n c e
15
T e
c h
n i
c a
l
G u
i d
a n
c e
16
In accordance with the bone classification of Lekholm and Zard (1985)
IMPLANTINDICATIONTABLE
Bone type IIBone type I Bone type III Bone type IV
Alvim Implant Apex"C" Implant Apex EX Implant Apex "M" Implant Apex
with Mount
with Mount
Morse Taper
Morse Taper
Morse Taper
17
Conical and Slim Fit Abutment (Ø 4.1 and Ø 4.3)
Conical Abutment (Ø 5.0)
Mini Conical Abutment (Ø 4.1 and Ø 4.3)
Mini Conical Abutment (Ø 5.0)
Mini Abutment Slim Fit
Universal Post, Personalizable, Angled and Slim Fit
UCLA (ø3.3)
UCLA (ø4.1; ø4.3; ø5.0)
Mini Ball Attachment
Cylinders
20N.cm
20N.cm
20N.cm
20N.cm
32N.cm
32N.cm
32N.cm
32N.cm
20N.cm
32N.cm
15N.cm
32N.cm
20N.cm
20N.cm
20N.cm
20N.cm
20N.cm
10N.cm
20N.cm
10N.cm
10N.cm
20N.cm
32N.cm
32N.cm
15N.cm
CM and WS Abutment
Angled Mini Conical Abutment CM
CM Mini Conical Abutment and WS and CM Micro Abutment
Universal Post CM and WS
Universal Post Througt Bolt and Angled
Mini Ball Attachment
Cylinders
Conical Abutment II Plus
Mini Abutment II Plus
Universal Post II Plus
Angled Post II Plus
UCLA II Plus
Mini Ball Attachment
Cylinders
EXTERNALHEX
INTERNALHEX
TRANSGINGIVAL
MORSETAPER
Cylinders
0.9 1.2 1.6 4.1Conical
GT
CONNECTIONSANDTORQUES
SELECTIONOFPROSTHETICCOMPONENTSACCORDINGTOTHEABUTMENT/IMPLANTINTERFACE
MultipleProsthesis
MultipleProsthesis
A.Overdentureabutment B.Directlyontheimplant
Workingmanner
MultipleProsthesis
MultipleProsthesis
SingleProthesis
SingleProthesis
SingleProthesis
SingleProthesis
TypeofProsthesis
1. Screw retained
2. Cemented
•Mini Conical Abutment•Transepithelial Abutment•Micro abutment
•Conical Abutment•CM Abutment
•Universal Post •Universal Post •Personalizable Post
•Universal Post •Personalizable Post
•UCLA
•UCLA
18
HeightoftheCMAngledProstheticComponents
AngledUniversalPost
ø4.5ø3.3
AngledMiniConicalAbutment
30º
17º
30º
5.8
0
4.5
05
.20
4.9
0
4.8
0
3.5
04
.20
3.9
0
3.8
0
2.5
03
.20
2.9
0
3.5
0
3.5
03
.50
3.5
0
4.9
0
3.5
0
5.9
0
3.5
0
2.5
0
2.5
02
.50
2.5
0
3.9
0
2.5
0 4.9
0
2.5
0
1.5
0
1.5
01
.50
1.5
0
2.9
0
1.5
0 3.9
0
1.5
0
19
RESPECTING YOUR WORK:
CYLINDERS FOR OVERCASTING
The cylinders and UCLAs for overcasting present
with perfect adaption and perfect fitting,
following international quality regulations and
standards. The dimensional tolerance between
implants, intermediates and manufactured belts,
as well as the individual analysis of each piece,
are the differences of these components that
pass through strict industrial quality control at a
micrometric level.
All of these products are manufactured using the
latest equipment, ensuring the best adaption.
Castable polymers sleeves fitted over the
metal bases are replaced with metal after the
overcasting process, thus the pre-fabricated
metalic base has a higher fusion temperature
than the metal to be overcast. Such polymers
facilitate the finishing process of the parts and
ensure the overlapping of the overcast metal to
the pre-manufactured metal. However, the casting
process does not follow the same quality control
that the manufacturing process does, therefore,
the dental technician should often check for
the absence of positive metallic porosities in the
screw passage tube. Therefore, the overcasting
technique maintains the quality of the fittings
among the guaranteed parts from the factory and
enables the design and individualisation of the
infrastructure, to allow additional material on the
manufactured base to hold its shape.
The use of these products should be carried
out in accordance with the handling instructions
as described in the manual, as well as in the
instructions provided by the various manufacturers
of overcasting alloys. Thus, the oral rehabilitation
team can ensure success for the technique more
safely. For best results, always use the entire
sequence of Neodent® products (analogues,
abutments, screws, transfer copings, and protectors).
Believing in the importance of allowing the
customer to choose the product, we offer different
metallic alloy cylinders with pre-fabricated belts
bases for overcasting.
They are:
− Cobalt-Chromium;
− Tilite;
− Gold (Gold Alloy);
− Zirconia.
NE
OD
EN
T
20
NE
OD
EN
T
HANDLING OF
CYLINDERS FOR OVERCASTING
Regardless of the type of alloy chosen, the
dental technician should take special care when
handling the pre-fabricated cylinders, thus
improving the quality of the overcasting and the
ceramic application processes.
1. Waxing:
The edges waxing of the component cannot
overrun the borders that come into contact with
the implant or the prosthetic component (metallic
base of cylinder), guaranteed to preserve and
adapt the industrial quality control process.
2. Overcasting:
The prosthetic cylinders are made non-sterile
and are suitable for single use. The metal bases
are manufactured with alloys that have a high
fusion temperature compared to the metal that
is to be overcast. In cases where the metal for
overcasting has a higher fusion temperature than
the manufactured parts, they will deform due
to high temperatures. However, if the metal due
to be overcast has a fusion temperature much
lower than the metal in the base, bonding may
occur between the parts and the base of the
component, which could result in the release of
the infrastructure.
All the cylinders with pre-fabricated bases are
evaluated one by one, from the reception of the
raw material, which is analysed before production,
to its final packaging, ensuring quality throughout
the entire manufacturing process.
3. Finishing and metal polishing:
The disembedding of the casted object at
the coating must be done carefully, avoiding
abrasive jets blasts, which may alter the pre-
fabricated surface.
It is recommended to machining the final
infrastructure at a low rotation with the use
of refrigeration, with specific drills for metal.
Both of the areas corresponding to the stop of
the head of the prosthetic screws inside the
passing tube must maintain their full original
shape, without the presence of positive metal
porosities or deformations.
The edges of the cylinders must be covered by
polishing protectors during the polishing and
the finishing of the infrastructure. Corrosive
materials, such as those with iron particles,
should also not be used.
Very strict criteria should be applied, because
flaws in overcasting procedure may cause the
loss of the entire work.
4. Ceramic application:
The porcelain choice should correspond
to the used alloy (CoCr, Tilite or Gold). The
ceramic cannot be applied directly over the
manufactured bases of the cylinder, so that the
waxing and the overcasting ensure a complete
covering of the infrastructure area in which the
ceramic is to be applied.
21
NE
OD
EN
T
COBALT-CHROMIUMPRODUCTS LINE (CoCr)
The cylinders for overcasting with pre-
fabricated bases of Cobalt-Chromium (CoCr),
have a high resistance to water corrosion and
elevated mechanical resistance to withstand
occlusal loads. This is an alloy that has a high
biocompatibility and is easy to use by the
technician, with an excellent acceptance of
ceramic application for CoCr. In addition, this alloy
is compatible with one of the strongest trends in
healthcare worldwide in its absence of Nickel in
its chemical composition, resulting in lower risks
of allergenic reactions when in contact with living
tissues, such as the oral mucosa.
Several cylinders and UCLAs are available in this
alloy, and from the customised infrastructures
of the Neoshape line. Note the options and
mechanical characteristics (rotational or anti-
rotational) for each case, as well as the sequence
of products found in this catalogue.
ThechemicalcompositionofthehighfusionCoCralloy
followsisinaccordancetotheinternationalregulation
ASTMF-1537,byfollowingthischemicalcomposition:
Importantinformation:
•Melting range: 1.287 to 1.378°C (2.348 to 2.512 °F);
• Density: 8,28 g/cm³;
• Coefficient of thermal expansion: 14,2µm/K
(600°C).
An alloy compatible for the overcasting procedure
that is in accordance with regulations ASTM F1537,
ASTM F799, ISO 5832-12 or ISO 5832-4 should be
chosen.
The thickness of the metal after overcasting must
be at least 0.5 mm, and can be reduced during
manufacturing and finishing by up to 0.3 mm.
Welding must be done in the range of 1.120 to
1.150°C (2.048 to 2.102 °F)
CHEMICAL ELEMENT Composition (%)
Cobalt 58to69
Chrome 26to30
Molybdenum 5to7
Max.Nitrogen 0,25
Max.Carbon 0,14
22
NE
OD
EN
T
TILITE LINE
The cylinders for overcasting with pre-fabricated
bases in Tilite must always be overcast with
Tilite alloys (Talladium, Curitiba, Brazil). The Tilite
metallic alloys are alloys with a highly resistant
NiCr base. The pre-fabricated base has a high
fusion temperature, accepting only the Tilite
alloys for overcasting. Depending on the ceramic
used by the dental technician, they must select
which Tilite alloy is to be made in overcasting,
according to the table below:
Several cylinders and UCLAs are available in
this alloy. Note the options and mechanical
characteristics (rotational or anti-rotational) for
each case, as well as the sequence of products
found in this catalogue.
Importantinformation:
•Melting range: 1.204 to 1.302°C (2.200 to
2.375 °F);
•Density: 7,7 g/cm³;
•Coefficient of thermal expansion: varies
according to the Tilite league selected;
•Welding must be done in the range of
1.050 to 1.110°C (1.922 to 2.030 °F).
Moreinformationcanbefoundinthis
article:SARTORI,IAM;VELOSO,R.Neodent
andTalladium:CastingoftheTilite
manufacturedcomponents.ImplantNews,
no.5,vol.2,Sept/Oct2005.
CHEMICALELEMENT Composition(%)
Níckel 60to76
Chrome 12to21
Molybdenum 4to14
Titanium 4to6
TILITE ALLOY CERAMIC
Carmen,CeramaxCeramco,CeramcoII,CeramcoIII,C-Mix,Duceram,DuceramKiss,Elephant,Excelco,Excelsior,Finesse,Fortune,GCInitialMC,Illusion,IPSInLine,Jelenko,LifeEssence,Micro-Bond,Microlucent,OlympicII,Pencraft,Reflex,Silhouette,Solera,Tru-Est,Vintage-Halo,Vision,Willians/Wilceram
BMK,Creation,DuceramPlus,Elite,HeraCeram,SymbioCeram,Vintage-Regular,VitaOmega900,VM13,VMK-68,VMK-68N
Avante,CeramcoIISilver,NoritakeEX-3,Spectrum,Starlight,Synspar
IPSClasic,IPSd.Sign,Vita,OmegaVMK-95
Luminesse
Premium(P)
Vita(V)
Star(S)
Omega(Ω)
PMF
23
NE
OD
EN
T
GOLD LINE
Among the metallic alloys, the cylinders for
overcasting with pre-fabricated bases in gold are to
be the first choice for the construction of prosthetic
infrastructures on dental implants. Of all of the
existing metallic alloys for the manufacture of
dental prosthesis, none were better than the gold
alloys in relation to intraoral survival time due to
their following characteristics:
• Excellent biocompatibility: no cytotoxic potential
(extraction test ISO 10993-5) or allergenic reaction
(ISO 10993-10 maximized);
• Extremely low levels of corrosion (according to
regulation ISO/DIS 10271);
• Excellent mechanical properties;
• Reduction of friction coefficient between parts;
• Increased pre-load of the prosthetic screw.
From a technical point of view, this is an alloy
of easy handling for the DENTAL TECHNICIAN,
since it has an optimal hardness, low capacity for
deformation and a white colouring, which makes
aesthetics easier. Its high fusion temperature
permits overcasting with gold and semi-gold alloys
and results in complete safety for the ceramic
application.
Cylinders on mini abutments and UCLAs are
available in this alloy.
Importantinformation:
• Melting range: 1.400 to 1.490°C (2.552 to 2.714 °F);
• Density: 17,5 g/cm³;• Coefficient of thermal expansion: 12,2µm/K (600°C).
The alloys must be chosen to be compatible
with the overcasting procedure (gold or semi-
gold) that are in accordance with regulation
ISO 9693 and ISO 22674.
The thickness of the metal after overcasting
should be at least 0.5 mm.
Welding must be done in the range of 800 to
890°C (1.472 to 1.634 °F).
Thegoldalloywithahighmeltinghasthefollowingchemicalcomposition:
CHEMICALELEMENT Composition(%)
Gold 60
Palladium 20
Platinum 19
Iridium 1
24
NE
OD
EN
T
ALUMINA LINE
In line with global aesthetic trends, the following
cylinders are available for the sequence of
Universal Posts made of Aluminium Oxide: The
Alumina line, indicated to cemented unitary
prostheses without metal, have the following
characteristics:
• Superior aesthetics and excellent
biocompatibility;
• Absence of metallic margin;
• Best translucency;
• Security on marginal adaptation;
• Effective Mechanical properties;
• No possibility of thermal conductivity or
oxidation;
• Excellent cost/ benefit;
• Technical procedures widely known by the
DENTAL TECHNICIANS.
Note the sequence of procedures for utilization of
this product found in this catalogue.
Aluminized feldspatic ceramics are suitable for
the application of these Alumina cylinders. Some
situations require the customisation of the cylinder
in order to avoid the excess of unsupported
feldspar ceramics, as following the manufacturer’s
instructions of the ceramics. For this, the DENTAL
TECHNICIAN must use aluminized ceramics of
margin or reconstruction, fabricating the final
infrastructure before the application of the porcelain.
25
NE
OD
EN
T
ZIRCONIA PRODUCTS LINE (Y-TZP)
Zirconium (Zr) is the basic chemical element of
Zirconia line. In accordance with the periodic
table, this is a transition metal and has many
interesting features, such as high mechanical
and corrosion resistance. From this element, is
obtained Zirconium Dioxide (ZrO2), better known
as Zirconia.
Zirconia has white colour and a crystalline
monocyclic structure. The addition of Yttrium
Oxide (Y2O3) in its composition results in the
formation of a tetragonal crystal (TPZ), which,
from a mechanical point of view, is very important
because it inhibits the propagation of cracks, a
fact commonly noted in ceramics in general.
With the scientific name of Tetragonal Zirconium
Oxide Polycrystal, stabilized with dense Yttrium
highly pure (Y-TZP), the Zirconia line is compliant
with regulation NBR ISO 13356. It has the
following characteristics:
•Biocompatibility;
•White colouring;
•High resistance to corrosion;
•Limits the formation of cracks;
•High fracture tenacity.
Today, there are few industries that have the
technology to process Zirconia. Therefore, after
intensive research, we can offer our clients a
line of UCLAs, Universal and Anatomical Posts,
as well as customizable infrastructures with our
Neoshape line. Not the sequence of this product
found in this catalogue.
Importantinformation:
•Density: 5,3 g/cm³;
•Flexural resistance: ≥ 1700 MPa.
Special care must be taken when handling
Zirconium. The Posts, UCLAs, and infrastructures
should not be subjected to the sterilisation,
which may result in the loss of their mechanical
properties. Moreover, some precautions should be
taken during the preparation:
•The use of fine grained diamond drills;
•Sufficient refrigeration;
•Finishing with specific rubber rotatory
instruments to avoid micro-cracks.
Porcelains specific for Zirconia must be chosen for
application. Note that in some cases the UCLAs
may need the infrastructure in order to increase
the ceramic volume supported in function of
the distance of the antagonist and proximal
dental elements. The Universal Posts must have
infrastructures, whether customizable with
Neoshape system, or over aluminium cylinders.
26
NE
OD
EN
T
CASTABLE PRODUCTS LINE
A product line that gives to DENTAL TECHNICIAN
complete freedom to cast the infrastructure with
a metallic alloy of their choice, directly over the
implant platform or abutment. Often, price is
the decisive factor in this choice. Therefore, the
adaptation quality to the implant primarily depends
on the care in handling by the professional,
providing quality assurance of prosthetic
components with pre-fabricated metallic base.
After casting, we suggest that you always evaluate
the adaptation of the analogues prior to cementing
the crown.
The castable components are available for all
cylinders on intermediary, Universal Posts and
UCLAs. Note the sequence of this product found in
this catalogue.
27
NE
OD
EN
T
TITANIUM LINE
Among the more traditional alloy in implantology,
there is the Titanium, conforming to regulation
ASTM F136- Ti6Al4V. Known as Titanium grade V,
it is widely used in the manufacture of provisional
prosthesis. The dentist or the DPT can adapt resin
crowns pre-fabricated over the cylinders and can
create temporary crowns with perfect fitting and
security, or even create a temporary crown directly
over the cylinders, which can be used in immediate
loading situations. The prosthetic components in
Titanium are provided sterile, guaranteeing security
and strengthening our ethical commitment with
you. Pre-fabricated components in Titanium must
not be overcasted. Although Titanium has a high
fusion temperature (approx 1680 ºC), the alloy
undergoes structural changes when subjected to
high temperatures. Therefore, metallic alloys with
Titanium base still remain a challenge to the science
of dental material.
The Titanium prosthetic components are offered as
cylinders for all intermediates and implants, also as
customized infrastructures with the Neoshape line.
Note the mechanical characteristics (rotational or
anti-rotational) of each case and the sequence of
products found in this catalogue.
28
M o r s e T a p e r
29
•GAPreduced(impermeablefitting);
•StableAnti-rotationalfixing;
•Highmechanicalstrength;
•Uniqueprostheticinterface,independentoftheimplantdiameter;
•FirstsystemwithConemorsefittinginBrazil;
•TheCMangleandtheinternalthicknessoftheimplantenable
thedesignofthescrewthreadtoreachthecervicalportionofthe
implant;
•Highresistance,comparabletoimplantswithexternalhexwith
regularplatform;
•NeoPorosSurface.
•CM Angled Universal Post 17° and 30°
•CM Universal Post Throug Bolt •CM Universal Post (unique
body)•Anatomical and Universal
Zirconia Post
•CM Mini Ball Attachment•Clip Bar•CM Mini Abutment•CM Micro Abutment
•CM Micro Abutment •CM Mini Abutment •Angled Mini Conical Abutment
17° and 30° •Cylinder and Distal Bar
Passive Fitting Technique•Cylinder - Castable Mini Abutment •Cylinder - Titanium Mini Abutment •Cylinder - Brass Mini Abutment
•WS Abutment (single)•Mini Abutment WS(multiple)•CM TransepithelialAbutment (multiple)
•CM Abutment (single) •Mini Abutment CM
(multiple)•Angled Mini Abutment CM
17º and 30º (multiple)Micro Abutment CM
(multiple)
• WS Universal Post with Screw
•Mini Abutment WS
Passive Fitting Technique• Castable GT Cylinder• Titanium GT Cylinder• Brass GT Cylinder
CONEMORSEIMPLANT
WSCONEMORSECMZYGOMATIC
3.5, 3.75, 4.0,4.3 e 5.0 mm
4.0, 5.0 e 6.0 mm
ScrewretainedProsthesis
CementedProsthesis Overdenture Protocol
ø2.5mm
Ø3.0mm
ØImplant
ØImplant
MORSETAPER
30
Imp
lan
ts
•Cylindrical implant with Morse Taper interface;
•NeoPoros Surface;
•Pre-mounted;
•Double thread (faster installation and less trauma);
•High cutting capacity;
•Suitable for bones type I and II;
•Cover screw not included;
•Unique prosthetic interface for all implant diameters;
•Cervical diameter equal to implant diameter;
•Observe the specific Pilot Drill (same function of countersink drill);
•Better prosthetic resolution with CM Implant inserted 2mm
intraosseous,below the crest level;
•Perforation rotation: 800-1200 rpm;
•Insertion rotation: 30 rpm.
3.5mm
3.75mm
4.0mm
5.0mm
ProductCharacteristics
Optional
Init
ial
Dri
ll
Tita
max
Dri
ll 2
.0
Pil
ot
2/3
Tita
max
Dri
ll 2
.8
Tita
max
Dri
ll 3
.0
Tita
max
Dri
ll 3
.15
CM
Pil
ot
2.8
/3.5
Tita
max
Dri
ll 3
.3
CM
Pil
ot
3/3
.75
CM
Pil
ot
3.3
/4.0
Tita
max
Dri
ll 3
.8
Tita
max
Dri
ll 4
.3
CM
Pil
ot
4.3
/5.0
DrillSequence
31
Ø 5.0
Ø 4.0
7.0 mm 8.0 mm 9.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm
109.556 109.557 109.558 109.559 109.560 109.561 109.562
109.544
109.529
109.545
109.530
109.546
109.531
109.547
109.532
109.548
109.533
109.549 109.550
109.509 109.510 109.511 109.512 109.513 109.514 109.515
Ø 3.5
Ø 3.75
CMCoverScrew
117.013 117.017
2 mm
Healings
Ø 3.3
Ø 4.5
5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm 6.5 mm
106.182 106.168 106.169 106.170 106.183 106.184 106.185
106.175 106.171 106.172 106.173 106.174 106.180 106.181
32
Imp
lan
ts
Optional
3.5mm
3.75mm
4.0mm
• Cylindrical implant with Morse Taper interface;
• NeoPoros Surface;
• Pre-mounted;
• Double thread (faster installation and less trauma);
• High compaction capacity (bone expansion);
• Suitable for bones type III and IV and in areas with little bone thickness ;
• Cover screw not included;
• Unique prosthetic interface for all implant diameters;
• Cervical diameter equal to implant diameter;
• Simplified instrumentation in the prepare of surgical alveolus;
• Best prosthetic resolution with CM Implant 2mm infraosseous;
• Perforation rotation: 800-1200 rpm;
• Insertion rotation: 30 rpm;
ProductCharacteristics
Init
ial
Dri
ll
Tita
max
Dri
ll 2
.0
Pil
ot
2/3
Tita
max
Dri
ll 2
.8
Tita
max
Dri
ll 3
.0
CM
Pil
ot
2.8
/3.5
Tita
max
Dri
ll 3
.3
CM
Pil
ot
3/3
.75
CM
Pil
ot
3.3
/4.0
Tita
max
Dri
ll 3
.8
Tita
max
Dri
ll 4
.3
CM
Pil
ot
4.3
/5.0
Drillsequence
Morse Taper
33
Ø 4.0
9.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm 19.0 mm
Ø 3.5
Ø 3.75
109.563 109.564 109.565 109.566 109.567
109.568 109.569 109.570 109.571 109.572 109.573
109.516 109.517 109.518 109.519 109.520 109.521
117.013 117.017
2 mm
Ø 3.3
Ø 4.5
5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm 6.5 mm
106.182 106.168 106.169 106.170 106.183 106.184 106.185
106.175 106.171 106.172 106.173 106.174 106.180 106.181
CMCoverScrew
Healings
Mo
rs
e T
ap
er
34
Imp
lan
ts
ProductCharacteristics
•Cylindrical implant with Morse Taper interface;
• NeoPoros Surface;
• Pre-mounted;
• Double thread (faster installation and less trauma);
• High compaction capacity (bone expansion);
• Suitable for bones type III and IV;
• Cover screw not included;
• Unique prosthetic interface for all implant diameters;
• Observe the specific Pilot Drill (same function of countersink drill);
• Cervical diameter equal to implant diameter;
• Best prosthetic resolution with CM Implant 2mm infraosseous;
• Perforation rotation: 800-1200 rpm;
• Insertion rotation: 30 rpm;
3.75mm
4.0mm
Optional
Drillsequence
Init
ial
Dri
ll
Tita
max
Dri
ll 2
.0
Pil
ot
2/3
Tita
max
Dri
ll 2
.8
Tita
max
Dri
ll 3
.0
CM
Pil
ot
2.8
/3.5
Tita
max
Dri
ll 3
.3
CM
Pil
ot
3/3
.75
CM
Pil
ot
3.3
/4.0
Tita
max
Dri
ll 3
.8
Tita
max
Dri
ll 4
.3
CM
Pil
ot
4.3
/5.0
35
Ø 4.0
9.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm
Ø 3.75
109.594
109.599
109.595
109.600
109.596
109.601
109.597
109.602
109.598
109.603
117.013 117.017
2 mm
Ø 3.3
Ø 4.5
5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm 6.5 mm
106.182 106.168 106.169 106.170 106.183 106.184 106.185
106.175 106.171 106.172 106.173 106.174 106.180 106.181
CMCoverScrew
Healings
36
Imp
lan
ts
ProductCharacteristics
• Conical implant with Morse Taper interface;
• NeoPoros Surface;
• Pre-mounted;
• Double thread (faster installation and less trauma);
• Suitable for bones type III and IV and pos-extracting installation;
• Cover screw not included;
• Unique prosthetic interface for all implant diameters;
• Observe the specific Pilot Drill (same function of countersink drill);
• Cervical diameter equal to implant diameter;
• Best prosthetic resolution with CM Implant 2mm infraosseous;
• Perforation rotation: 500-800 rpm;
• Insertion rotation: 30 rpm;
3.5mm
4.3mm
5.0mm
Optional
Drillsequence
Init
ial
Dri
ll
Alv
im D
rill
2.0
Alv
im D
rill
3.5
CM
Pil
ot
2.8
/3.5
Alv
im D
rill
4.3
CM
Pil
ot
3.6
/4.3
Alv
im D
rill
5.0
CM
Pil
ot
4.3
/5.0
37
8.0 mm 10.0 mm 11.5 mm 13.0 mm 16.0 mm
Ø 3.5
Ø 4.3
Ø 5.0
109.551 109.552 109.553 109.554 109.555
109.534 109.535 109.536 109.537 109.538
109.539 109.540 109.541 109.542 109.543
117.013 117.017
2 mm
Ø 3.3
Ø 4.5
5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm 6.5 mm
106.182 106.168 106.169 106.170 106.183 106.184 106.185
106.175 106.171 106.172 106.173 106.174 106.180 106.181
CMCoverscrew
Healings
38
Imp
lan
ts
5.0mm
4.0mm
6.0mm
Optionalforthe"M"Implant
ProductCharacteristics
• Cylindrical implant with Morse Taper interface;
• NeoPoros Surface;
• Pre-mounted;
• Cover screw not included;
• Optimization of primary stability;
• Excellent alternative to posterior edentulous lower jaw;
• Specific Surgical Kit;
• Observe the specific Pilot Drill (same function of
countersink drill);
• In "M" Titamax WS Implant, the pilot drill is optional;
• Perforation rotation: 200-300 rpm;
• Insertion rotation: 30 rpm;
• Unique Morse Taper prosthetic interface (same dimensions
as CM Zygomatic Implants).
Morse Taper
Drillsequence
Init
ial
Dri
ll
Tita
max
Dri
ll 2
.0
Pil
ot
2/3
Tita
max
Dri
ll 2
.8
Tita
max
Dri
ll 3
.0
CM
Pil
ot
2.8
/3.5
Tita
max
Dri
ll 3
.3
CM
Pil
ot
3/3
.75
CM
Pil
ot
3.3
/4.0
Tita
max
Dri
ll 3
.8
CM
Pil
ot
3.8
/4.3
Tita
max
Dri
ll 4
.3
CM
Pil
ot
4.3
/5.0
CM
Pil
ot
4.3
/5.3
Tita
max
Dri
ll 5
.3
CM
Pil
ot
5.3
/6.0
39
5.0 mm 6.0 mm
Ø 4.0
Ø 5.0
Ø 6.0
109.604
109.574
109.605
109.575
109.576 109.577
117.016
WS
3.5 mm2.5 mm1.5 mm0.8 mm
106.186 106.187 106.188 106.189
5.0 mm 6.0 mm
Ø 5.0
Ø 6.0
109.578 109.579
109.580 109.581
Mo
rs
e T
ap
er
CMCoverscrew
Healings
40
Pro
ste
tic
s C
om
po
ne
nts Demonstrativesequenceof
MorseTaper
CMAbutmentandWSAbutment
CM Abutment WS Abutment
Torque Connection 1.6 mm
Prosthetic Torque Ratchet Driver
GT Open Tray Transfer
GT Transfer
GT Analogue
GT Protective Cylinder
GT Cylinder
Tili
te /
Co
Cr
Titanium
Castable
Torque Connection 1.2mm
Prosthetic Torque Ratchet Driver
32N.cm
• Same prosthetic sequence as the GT Implant;
• Available in Titanium;
• Minimum interocclusal space of 5.0mm from the mucosa level;
• Conicity 15°;
• Single screw retained prosthesis (anti-rotational);
• The cylinders come with Neotorque screw, except the
castables, that comes with Titanium screw.
41
Dem
onstrativesequenceof
CMAbutm
entand
WSAbutm
ent
123.012
GTPolishingProtector
106.102
GTProtectionCylinder
108.039
Open tray
Closed tray
108.040
101.037
GTTransfer
GTAnalogue
GTCylinderScrew
Titanium Neotorque
116.038 116.228
Castable
Anti-rotational
Titanium Tilite CoCr
GTCylinder
0.8mm
0.8mm
1.5mm
1.5mm
2.5mm
2.5mm
3.5mm
3.5mm
4.5mm 5.5mm 6.5mm
CMAbutment
WSAbutment
115.162
115.180
115.147
115.181
115.148
115.182
115.152
115.183
115.163 115.164 115.165
118.180 118.179 118.242118.176
•Observe corresponding sequence and indicated torque;• Use Torque connection 1.6 mm (105.006); • To torque control, use Prosthetic Torque Ratchet Driver (104.026).
• Available: -Titanium: for provisional prosthesis; -Tilite and CoCr: overcastting; -Castable: casting.• With screw;• To screw torque, use Torque Connection 1.2mm (105.005);• Observe indicated torque;• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
• Available in Titanium;• Replica of implant platform or prosthetic component;
• For prosthesis construction or prosthetic planning.
• Available in Titanium;• Used to protect the component during the prosthesis construction;
• To installation, use Digital Driver 1.2mm (104.007).
• For transference and impression of prosthesis;• Available in Titanium;• For open tray or closed tray technique;• Anti-rotational.
• Protector for cylinders during polishing and finishing of prosthesis;
• Use the corresponding screw to the cylinder for fixation.
MorseTaper
42
•Available in Titanium;
• Minimum interocclusal space of 4.4mm from the
mucosa level;
• Multiple and screw retained prosthesis;
• Conicality 20°;
• The cylinders come with Neotorque screw, except the
castables, that comes with Titanium screw.
Pro
sth
eti
cs
Co
mp
on
en
ts Demonstrativesequenceof
CMMiniAbutmentandWSMiniAbutment
WS Mini
Conical Abutment
CM Mini Conical
Abutment
Angled CM Mini Conical
Abutment (17° and 30°)
Connection to Conical Torque
4.1 mm
Connection to Conical Torque
4.1 mm
Connection to Torque 0.9 mm
Mini Conical Abutment Transfer
Mini Conical Abutment Analogue
Protective Cylinder of Mini Conical Abutment
Mini Conical Abutment Cylinder
Tili
te /
Go
ld /
Co
Cr
Titanium
Castable
Torque Connection 1.2mm
Prosthetic Torque Rachet Driver
Prosthetic Torque Ratchet Driver
32N.cm
32N.cm
15N.cm
MorseTaper
43
Dem
onstrativesequenceof
CMMiniAbutm
entand
WSMiniAbutm
ent
115.154
115.176
115.149
115.177
115.16617º
115.16930º
115.150
115.178
115.167
115.170
115.151
115.179
115.168
115.171
115.153 115.160 115.161
AnalogueofMiniConicalAbutment
Castable Titanium Tilite Gold CoCr CoCrfor weld
116.036
106.227116.037
0.8mm
0.8mm
1.5mm
1.5mm
1.5mm
2.5mm
2.5mm
2.5mm
3.5mm
3.5mm
3.5mm
4.5mm 5.5mm 6.5mm
CMMiniConicalAbutment
WSMiniConicalAbutment
AngledCMMiniConicalAbutment
•Observe corresponding sequence and indicated torque;•Observe indicated Torque Connection;•To control torque, use Prosthetic Torque Ratchet Driver (104.026);•Check the measurement of angled components in Catalog.
•Check measurements in “Technical Guidance”, on page 14.
CylinderofCM
MiniConicalAbutment
•Available in: -Titanium: provisional prosthesis; -Tilite and CoCr: overcastting; -Castable: casting; -Gold: gold alloy with high melting range. •Rotational for screwed retained multiple elements;•With screw;•To screw torque, use Torque Connection 1.2mm (105.009)•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
118.112ø4.1
ø4.1
ø4.1
ø4.1
ø4.1
ø4.1
118.113 118.146 118.206 118.209 118.210
106.054
ProtectiveCylinderofMiniConicalAbutment
108.022108.021 108.068
101.020
TransferofMiniConicalAbutment
Open-tray Closed-tray
Short screw
Multifunctional
CylinderScrew
Titanium Neotorque
•Available in Titanium;•Replica of prosthetic component;•For prosthesis construction or prosthetic planning.
•Available in Titanium;•Used to protect the component during the prosthesis construction;•To installation, use Digital Driver 1.2mm (104.007).
•Available in Titanium;•Component with molding function by prosthesis construction;•For open tray or closed tray technique;•Rotational.
123.008
PolishmentProtector
•Protector for cylinders during polishing and finishing of prosthesis;•Use the corresponding screw to the cylinder for fixation.
MorseTaper
44
Mini Conical Abutment Cylinder
CoCr
Titanium
CM Micro Conical Abutment
Connection to Conical Torque
Prosthetic Torque Ratchet Driver
Mini Conical Abutment Transfer
Mini Conical Abutment Analogue
Protective Cylinder of
Mini Conical Abutment
Torque Connection 1.2mm
Prosthetic Torque Ratchet Driver
32N.cm
Pro
sth
eti
cs
Co
mp
on
en
ts DemonstrativeSequenceof
CMMicroAbutment
•Available in Titanium;
•Multiple and screwed prosthesis;
•Indicated to CM Implants with diameter of 3.5mm
and close to each other;
•Minimum interocclusal space of 4.4mm from the
mucosa level;
•The cylinders come with Neotorque screw, except
the castables, that comes with Titanium screw.
MorseTaper
45
Dem
onstrativeSequenceof
MorseTaper
CMMicroAbutm
ent
OpenTrayTransferofMicroConicalAbutment
118.246
Titanium
118.245 118.247
CoCr Castable
115.200 115.201 115.202
1.5mm 2.5mm 3.5mm
CMMicroConicalAbutment
• Observe sequence and torque;• To torque, use Conical Torque Connection 4.1mm (105.009);• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
MicroConicalAbutmentCylinder
•Available in: -Titanium: provisional prosthesis; -CoCr: overcastting; -Castable: casting.•Rotational for screwed multiple elements;•With screw;•To screw torque, use Torque Connection 1.2mm (105.009)•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
106.227116.037
ø4.1 106.199
ProtectiveCylinderofCMMicroAbutment
CylinderScrew
Titanium Neotorque
• Available in Titanium;• Used to protect the component during the prosthesis construction;
• To installation, use Digital Driver 1.2mm (104.007).
MicroConicalAbutmentAnalogue
108.070
101.057 Rotational
•Available in Titanium;•Replica of prosthetic component; •For prosthesis construction or prosthetic planning. •Available in Titanium;
•Component with molding function by prosthesis construction;•For open tray technique;•Rotational.
46
CM Implant Transfer
Analogue of CM Implant
Torque Connection 0.9 mm
Prosthetic Torque Ratchet Driver
Optional SequenceIndicated Sequence
CM Anatomic Post
Customization
ConventionalMolding
LaboratorialPhase
Laboratorial Phase
Prosthesis Conclusion
Torque Connection 0.9 mm
Prosthetic Torque Ratchet Driver
CM AnatomicPost
15N.cm
15N.cm
Pro
sth
eti
cs
Co
mp
on
en
ts
DemonstrativeSequenceof
CMAnatomicPost
•Available in Zirconia, according to
ASTM ISO 13.356;
•Cemented unitary prosthesis;
•Possible customization;
•Indicated for aesthetic area.
MorseTaper
47
1.5mm 2.5mm 3.5mm
CMLateralAnatomicPost
114.332Zirconia 114.333 114.334
CMImplantTransfer
108.041 108.065
ShortLong
• Available in Titanium;• Component with molding function by prosthesis construction;
• For closed tray technique.
CMImplantAnalogue
101.053
•Available in Titanium;•Replica of prosthetic interface;•For prosthesis construction or prosthetic planning.
1.5mm 2.5mm 3.5mm
CMAnatomicPost
•To installation, use Torque Connection 0.9mm (105.065);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
•Available in Zirconia;•Cemented prosthesis;•To installation, use Torque Connection 1.2mm (105.005);•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
114.321Zirconia 114.322 114.323
Dem
onstrativeSequenceof
MorseTaper
CMAnatomicPost
48
Torque
Connection 1.2mm
Prosthetic Torque Ratchet Driver
CM Post Transfer
CM Post
Analogue
Universal
Post Cylinder
ø 3.3
ø 3.3
ø 3.3
ø 4.5
ø 4.5
ø 4.5
Aluminium
Aluminium
Temporary
Temporary
Castable
Castable
32N.cm
ø3.3 x 4 ø3.3 x 6 ø4.5 x 6
Pro
sth
eti
cs
Co
mp
on
en
ts
•Cemented prosthesis;
•Straight Universal Post in Titanium body;
ø4.5 x 4
DemonstrativeSequenceof
CMUniversalPostMorseTaper
49
114.129 114.077 114.078 114.079 114.136 114.137
114.130 114.086 114.087 114.088 114.139 114.140
114.131 114.080 114.081 114.082 114.142 114.143
114.132 114.083 114.084 114.085 114.145 114.146
114.138
114.141
114.144
114.147
UniversalPostTransfer
UniversalPostSetUniversalPostAnalogue
118.186
108.042
108.060101.038
118.181 118.192
118.188
108.044
108.062101.040
118.183 118.194
118.187
108.043
108.061101.039
118.182 118.193
118.189
108.045
108.063101.041
118.184 118.195
TemporaryAluminum Castable
UniversalPostCylinder
0.8mm
ø 3.3
ø 3.3
ø 3.3
ø 3.3
ø 3.3
ø 3.3 ø 3.3
ø 3.3
ø 3.3
ø 3.3 ø 3.3
ø 3.3
ø 3.3
ø 3.3
ø 4.5
ø 4.5
ø 4.5
ø 4.5
ø 4.5
ø 4.5
ø 4.5 ø 4.5
ø 4.5
ø 4.5
ø 4.5 ø 4.5
ø 4.5
ø 4.5
4mm
4 mm
4 mm
4mm
4 mm
4 mm
4 mm
6 mm
6mm
6mm
6mm
6mm
6mm
6mm
1.5mm
1.5mm
2.5mm
2.5mm
3.5mm
3.5mm
4.5mm 5.5mm 6.5mm
CMUniversalPostinTitanium
AngledCMUniversalPostinTitanium
• Available in Titanium;• Observe indicated torque and connection;• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
• Available in: -Titanium: provisional prosthesis; -Alumina: for “metal free” prosthesis; -Castable: casting.• Cemented prosthesis;• Compatible with all Universal Posts, if not prepared.
• Available in polymer;• Component with molding function by prosthesis construction;
• For closed tray technique;• Anti-rotational;• Select transfer according to the component to be molded, as prosthetic planning.
• Available in Titanium;• Replica of prosthetic component platform;• For prosthesis construction and prosthetic planning.
• Components Kit of Universal Post line, containing the Transfer and Provisional / Castable Cylinders.
114.095
114.101
114.107 114.108 114.109
114.110 114.111 114.112
114.102 114.103
114.104 114.105 114.106
114.096 114.097
114.098 114.099 114.100
114.089 114.090 114.091
114.092 114.093 114.094
17º
30º
•See measurements in “Technical Guidance”.
Dem
onstrativeSequenceof
CMUniversalPost
MorseTaper
50
Transfer of WS Implant
Transfer of Short CM Implant
CM Implant
Analogue
WS Implant
Analogue
Torque Connection 0.9 mm
Prosthetic Torque Ratchet Driver
CM Universal Post Through Bolt
Torque Connection
1.2mm
WS Post
Pro
sth
eti
cs
Co
mp
on
en
ts
Transfer of Long CM Implant
32N.cm
15N.cm
•Available in Titanium;
•Cemented unitary prosthesis;
•Need of Transfer Guide in acrylic resin
•Indicated for laboratorial customization.
DemonstrativeSequenceof
MorseTaper
CMUniversalPostThroughBolt
51
Dem
onstrativeSequenceof
MorseTaper
CMUniversal
PostThroughBolt
WSUniversalPost
114.183 114.184 114.185 114.186
114.187 114.188 114.189 114.190
0.8mm
ø4.5
4mm
6mm
1.5mm 2.5mm 3.5mm
• Available in Titanium;• Component with molding function by prosthesis construction;
• For closed tray technique.
114.293 114.294 114.295
114.300 114.301 114.302
114.286 114.287 114.288
114.289 114.290 114.291
ZirconiaUniversalPostThroughBolt
ø3.3
ø3.3
ø4.5
ø4.5
4mm
6mm
1.5mm 2.5mm 3.5mm
•Available in Zirconia; •Component with through bolt; •Cemented prosthesis; •Use a Torque Connector of 0.9 mm (105.006); for installation;
•Observe indicated torque; •Available in two heights 4mm and 6mm.
CMImplantTransfer
108.041 108.065 108.064
ShortLong WS
101.053 101.055
CM WS
Analogue
• Available in Titanium;• Replica of prosthetic interface;• For prosthetic planning.
114.148 114.149 114.150 114.151 114.152 114.153
114.155 114.156 114.157 114.158 114.159 114.160
114.115 114.117 114.118 114.119 114.162 114.163
114.116 114.120 114.121 114.122 114.165 114.166
114.164
114.167
114.154
114.161
CMUniversalPostThroughBolt
0.8mm
ø3.3
ø3.3
ø4.5
ø4.5
4mm
6mm
1.5mm 2.5mm 3.5mm 4.5mm 5.5mm 6.5mm
• Available in Titanium;• Component with through bolt;• Cemented prosthesis;• To installation, use Torque Connection 1.2mm (105.005);• Observe indicated torque;• Available in two heights: 4mm and 6mm.
• Available in Titanium;• Two pieces;• Component with through bolt;• Cemented prosthesis;• To installation, use Torque Connection 1.2mm (105.005);• Observe indicated torque;• Available in two heights: 4mm and 6mm.
52
Pro
sth
eti
cs
Co
mp
on
en
ts
CM Mini Ball Attachment
Conical Torque Connection 4.1 mm
Positioner
straight
Positioner
7º
Positioner
14º
•Available in Titanium;
•Directly over the implant;
•For Overdenture prosthesis, its function is the O’ring retention;
•It's recommended capture the components in patient's mouth, one by one;
•Application of Nitride Titanium coating for increased the wear resistance;
•O’ring with protection disc;
•See the demonstrative sequence of Mini Ball Attachment on page 131.
O’ring with Cylinder
Disc
32N.cm
BallAttachmentInstalled
Demonstrativesequenceof
MiniBallAttachmentMorseTaper
Prosthetic Torque Ratchet Driver
53
straight,7ºe14º
CastableBallAttachment
Positioners
102.069 102.070 102.071 102.097 102.098
CMMiniBallAttachment
1.5mm 2.5mm 3.5mm 4.5mm 5.5mm
•Available in Titanium; •Select according to the mucosa height; •To installation, use Torque Connection 1.2mm (105.005); •Castable: casting in various metals;
•May be cemented in natural roots or waxed in bars for overdenture retention.
•Available in polymer; •Indicated to define the correct distance between Attachment Ball components and O’ring with cylinder; •Corrects the parallelism between the implants;•Essential for O’ring capturing.
102.078
102.076
102.073
102.077
O’ringwithcylinder
O’ring
ProtectionDisc
102.075
O’ringRemover
O’ringMount
104.044
104.043
•Digital Driver with function of O’ring replacing to the cylinder.
•Digital Driver with function of O’ring replacing to the cylinder.
•Available in polymer;•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;
•Not Autoclavable.
•Available in polymer;•Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;
•Not Autoclavable.
•Packaging with 10 units.
Dem
onstrativesequenceof
MiniBallAttachm
ent
MorseTaper
54
E x t e r n a l H e x
55
•Results in the integrity of the External Hex;
•Maintains the original rotational freedom;
•Greater practicality and safety;
•Higher mechanical resistance to insertion;
•Transport tweezers for safety in the handling of the implant.
Hex2.37m
m
Hex2.7mm
Ø3.3mm
Ø4.1mm
1mm
0.7mm
Hex3.3mm
Ø5.0mm
Hex2.7mm
Ø 3.3
Ø 4.1
Ø 4.3
Ø 5.0
ScrewedProsthesis
CementedProsthesis Overdenture Protocol
•Mini Conical Abutment (multiple)
•Angled Mini Conical Abutment 17° (multiple) •Castable UCLA •Tilite UCLA •CoCr UCLA •Zirconia UCLA
•SF Mini Conical Abutment (multiple)
•Angled Mini Conical Abutment 17° and 30° (multiple)
•SF Conical Abutment (unitary) •Castable UCLA •Gold UCLA•Tilite UCLA •CoCr UCLA •Zirconia UCLA •UCLA Zirconia with Titanium
interface
•Mini Conical Abutment (multiple)
•Angled Mini Conical Abutment 17° and 30° (multiple)
•Conical Abutment (unitary) •Castable UCLA •Gold UCLA •Tilite UCLA •CoCr UCLA •Zirconia UCLA
•SF Mini Conical Abutment (multiple)
•Angled Mini Conical Abutment 17° and 30° (multiple)
•SF Conical Abutment (unitary)
•Castable UCLA •Tilite UCLA •CoCr UCLA •Zirconia UCLA
•Angled Post 17°•Universal Post •Customized Post•Castable UCLA •Gold UCLA •Tilite UCLA •Titanium UCLA •CoCr UCLA •Zirconia UCLA
•Mini Ball Attachment •Clip Bar •Mini Conical Abutment •Castable UCLA •Gold UCLA •Tilite UCLA •CoCr UCLA
•Angled Post 17°and 30° •Universal Post •Customized Post •Castable UCLA •Gold UCLA •Tilite UCLA •Titanium UCLA •CoCr UCLA •Zirconia UCLA •SF Post
•Mini Ball Attachment •Clip Bar •Mini Conical Abutment •Castable UCLA •Gold UCLA •Tilite UCLA •CoCr UCLA
•Mini Conical Abutment •Angled Mini Conical Abutment 17° and 30° •Cylinder and Distal External Bar Passive Fitting Technique • Cylinder of Castable Mini
Abutment • Cylinder of Titanium Mini
Abutment • Cylinder of Brass Mini
Abutment
•Mini Conical Abutment •Angled Mini Conical •Abutment 17° and 30° •Cylinder and Distal External Bar
Passive Fitting Technique • Cylinder of Castable Mini
Abutment • Cylinder of Titanium Mini
Abutment • Cylinder of Brass Mini
Abutment
•Angled Post 17° •Tilite UCLA •Castable UCLA •Titanium UCLA •CoCr UCLA •Zirconia UCLA
3.3 e 3.5 mm
3.75 e 4.0 mm
4.5 e 5.0 mm
4.5 e 5.0 mm
EXTERNALHEX
Inte
rnal
Thr
ead
Ø 1
.8In
tern
al T
hrea
d Ø
2.0
Inte
rnal
Thr
ead
Ø 2
.0In
tern
al T
hrea
d Ø
2.5 •Angled Post 17°
•Customized Post •Castable UCLA •Tilite UCLA •Titanium UCLA •CoCr UCLA •Zirconia UCLA
•Mini Ball Attachment •Clip Bar •Mini Conical Abutment •Castable UCLA •Gold UCLA •Tilite UCLA •CoCr UCLA
•Mini Conical Abutment •Angled Mini Conical •Abutment 17° and 30° •Cylinder and Distal External
Bar
Passive Fitting Technique • Cylinder of Castable Mini
Abutment • Cylinder of Titanium Mini
Abutment • Cylinder of Brass Mini
Abutment
1mm
1mm
Ø4.3mm
56
Imp
lan
ts
Drillingsequence
ProductCharacteristics
• Cylindrical implant with External Hex interface;
• NeoPoros Surface;
• Capture and installation with contra-angle or manual without
mount use (reduction of surgical time);
• Double thread (faster installation and less trauma);
• High cutting capacity;
• Suitable for bones type I and II;
• Cover screw and mount not included;
• Installation through implant internal hex, increasing the
mechanical resistance (when applied elevated torque),
preserving the external hex integrity;
• Perforation rotation: 800-1200 rpm;
• Installation rotation: 30 rpm;
3.75 mm
4.0 mm
4.5 mm
5.0 mm
Optional
Init
ial
Dri
ll
Tita
max
Dri
ll 2
.0
Pil
ot
2/3
Tita
max
Dri
ll 3
.0
Tita
max
Dri
ll 3
.15
Tita
max
Dri
ll 3
.3
Pil
ot
3/3
.75
Co
un
ters
ink
4.1
Tita
max
Dri
ll 3
.8
Tita
max
Dri
ll 4
.3
Co
un
ters
ink
5.0
57
Coverscrew
9.0 mm7.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm
Ø 4.0
Ø 3.75
Platform(4.1)
Platform(4.1)
Platform(5.0)
Ø 4.5
Ø 5.0
109.284 109.285 109.286 109.287 109.288
109.302 109.303 109.304 109.305 109.306
109.327 109.328 109.329
109.294 109.295 109.296 109.297
117.018 117.003
4.1 mm 5.0 mm
106.092
106.127 106.128 106.129 106.130
106.093 106.094 106.095
2.0 mm 2.0 mm3.0 mm 3.0 mm4.0 mm 4.0 mm5.0 mm 5.0 mm
Ø 4.1 Ø 4.1
Ø 5.0 Ø 5.0
DivergentHealings ParallelHealings
106.084
106.097 106.098 106.099 106.100
106.085 106.086 106.087
2.0 mm 3.0 mm 4.0 mm 5.0 mm
Ø 4.1
Ø 5.0
SlimFitHealings
106.195 106.196 106.197 106.198
106.190 106.191 106.192 106.193
58
Imp
lan
ts
ProductCharacteristics
•Cylindrical implant with External Hex interface;
• NeoPoros Surface;
• Capture and installation with contra-angle or manual without mount
use (reduction of surgical time);
• Double thread (faster installation and less trauma);
• High compaction capacity (bone expansion);
• Suitable for bones type III and IV;
• Cover screw not included;
• Simplified instrumentation in the prepare of surgical alveolus;
• Installation through implant internal hex, increasing the mechanical
resistance (when applied elevated torque), preserving the external hex
integrity;
• Prosthetic platform 4.1mm;
• Perforation rotation: 800-1200 rpm;
• Installation rotation: 30 rpm;
Optional
3.75mm
4.0mm
Internal Torque
Init
ial
Dri
ll
Tita
max
Dri
ll 2
.0
Pil
ot
2/3
Tita
max
Dri
ll 2
.8
Tita
max
Dri
ll 3
.0
Tita
max
Dri
ll 3
.3
Pil
ot
3/3
.75
Co
un
ters
ink
4.1
Tita
max
Dri
ll 3
.8
Tita
max
Dri
ll 4
.3
Co
un
ters
ink
5.0
Drillingsequence
59
9.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm 19.0 mm
Ø 4.0
Ø 3.75
109.588
109.582
109.589
109.583
109.590
109.584
109.591
109.585
109.592
109.586
109.593
109.587
117.018
4.1 mm
106.092 106.093 106.094 106.095
2.0 mm 2.0 mm3.0 mm 3.0 mm4.0 mm 4.0 mm5.0 mm 5..0 mm
Ø 4.1 Ø 4.1 106.084 106.085 106.086 106.087
2.0 mm 3.0 mm 4.0 mm 5.0 mm
Ø 4.1 106.190 106.191 106.192 106.193
Platform(4.1)
Platform(4.1)
Inte
rn
al
To
rq
ue
Coverscrew
DivergentHealings ParallelHealings
SlimFitHealings
60
Imp
lan
ts
ProductCharacteristics
3.75mm
4.0mm
5.0mm
•Cylindrical implant with External Hex interface;
• NeoPoros Surface;
• Capture and installation with contra-angle or manual without
mount use (reduction of surgical time);
• Double thread (faster installation and less trauma);
• High compaction capacity (bone expansion);
• Suitable for bones type III and IV;
• Cover screw not included;
• Simplified instrumentation in the prepare of surgical alveolus;
• Installation through implant internal hex, increasing the
mechanical resistance (when applied elevated torque),
preserving the external hex integrity;
• Prosthetic platform 4.1mm;
• Perforation rotation: 800-1200 rpm;
• Installation rotation: 30 rpm;
Optional
Drillingsequence
Init
ial
Dri
ll
Tita
max
Dri
ll 2
.0
Pil
ot
2/3
Tita
max
Dri
ll 3
.0
Tita
max
Dri
ll 3
.3
Pil
ot
3/3
.75
Co
un
ters
ink
4.1
Tita
max
Dri
ll 3
.8
Tita
max
Dri
ll 4
.3
Co
un
ters
ink
5.0
61
9.0 mm7.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm
Ø 4.0
Ø 3.75
Ø 5.0
109.311 109.312 109.313 109.314 109.315
109.289 109.290 109.291 109.292 109.293
109.298 109.299 109.300 109.301
117.018 117.003
4.1 mm 5.0 mm
Plataforma(4.1)
Plataforma(4.1)
106.092
106.127 106.128 106.129 106.130
106.093 106.094 106.095
2.0 mm 2.0 mm3.0 mm 3.0 mm4.0 mm 4.0 mm5.0 mm 5.0 mm
Ø 4.1 Ø 4.1
Ø 5.0 Ø 5.0
106.084
106.097 106.098 106.099 106.100
106.085 106.086 106.087
2.0 mm 3.0 mm 4.0 mm 5.0 mm
Ø 4.1
Ø 5.0 106.195 106.196 106.197 106.198
106.190 106.191 106.192 106.193
Coverscrew
DivergentHealings ParallelHealings
SlimFitHealings
62
Imp
lan
ts
•Conical implant with External Hex interface;
• NeoPoros Surface;
• Capture and installation with contra-angle or manual without
mount use (reduction of surgical time);
• Suitable for bones type III and IV and pos-extracting installation;
• Cover screw and mount not included;
• Simplified instrumentation in the prepare of surgical alveolus;
• Installation through implant internal hex, increasing the
mechanical resistance (when applied elevated torque),
preserving the external hex integrity;
• External Hex with height of 1mm: platform 4.3 and 5.0;
4.3mm
5.0mm
Optional
ProductCharacteristics
Drillingsequence
Init
ial
Dri
ll
Alv
im D
rill
2.0
Alv
im D
rill
3.5
Alv
im D
rill
4.3
Co
un
ters
ink
4.3
Alv
im D
rill
5.0
Co
un
ters
ink
5.0
63
Ø 5.0
Ø 4.3
10.0 mm 13.0 mm 16.0 mm
109.321 109.322 109.323
109.324 109.325 109.326
117.018 117.003
4.3 mm 5.0 mm
106.092
106.127 106.128 106.129 106.130
106.093 106.094 106.095
2.0 mm 2.0 mm3.0 mm 3.0 mm4.0 mm 4.0 mm5.0 mm 5.0 mm
Ø 4.1 Ø 4.1
Ø 5.0 Ø 5.0
106.084
106.097 106.098 106.099 106.100
106.085 106.086 106.087
2.0 mm 3.0 mm 4.0 mm 5.0 mm
Ø 5.0 106.195 106.196 106.197 106.198
Coverscrew
DivergentHealings ParallelHealings
SlimFitHealings
64
Imp
lan
ts
•Cylindrical implant with External Hex;
• NeoPoros Surface;
• Cover screw not included;
• Double thread (faster installation and less trauma);
• High cutting capacity;
• Suitable for bones type I and II in reduced prosthetic spaces
(upper lateral incisor and lower incisor);
• Prosthetic platform 3.3mm;
• External Hex with height of 1mm;
• Resistance to the installation torque : 45 N.cm;
• Perforation rotation: 500-800 rpm;
• Installation rotation: 30 rpm;
3.3mm
with Mount
ProductCharacteristics
Drillingsequence
Init
ial
Dri
ll
Tita
max
Dri
ll 2
.0
Tita
max
Dri
ll 2
.8
Co
un
ters
ink
3.3
65
11.0 mm9.0 mm 13.0 mm 15.0 mm 17.0 mm
Ø 3.3
109.140 109.141 109.142 109.143 109.144
117.001
3.3 mm
106.065 106.066 106.067 106.068
2.0 mm 2.0 mm3.0 mm 3.0 mm4.0 mm 4.0 mm5.0 mm 5.0 mm
Ø 3.3 Ø 3.3 106.060 106.061 106.062 106.063
Coverscrew
DivergentHealings ParallelHealings
wit
h M
ou
nt
66
Imp
lan
ts
•Conical implant with External Hex;
• NeoPoros Surface;
• Cover screw included;
• Suitable for bones type III and IV in reduced prosthetic spaces
(upper lateral incisor and lower incisor) and pos-extracting
installation;
• Prosthetic platform 3.3mm;
• External Hex with height of 1mm;
• Resistance to the installation torque : 45 N.cm;
• Perforation rotation: 500-800 rpm;
• Installation rotation: 30 rpm;
3.5mm
Init
ial
Dri
ll
Alv
im D
rill
2.0
Alv
im D
rill
3.5
Co
un
ters
ink
3.3
Optional
with Mount
Drillingsequence
ProductCharacteristics
67
Ø 3.5
10.0 mm 13.0 mm 16.0 mm
109.217 109.218 109.219
117.001
3.3 mm
106.065 106.066 106.067 106.068
2.0 mm 2.0 mm3.0 mm 3.0 mm4.0 mm 4.0 mm5.0 mm 5.0 mm
Ø 3.3 Ø 3.3 106.060 106.061 106.062 106.063
Platform(3.3)
wit
h M
ou
nt
Coverscrew
DivergentHealings ParallelHealings
68
Pro
sth
eti
cs
Co
mp
on
en
ts
•Available in Titanium;
• Minimum interocclusal space of 6.1mm on platform 4.1,
and 6.7mm on platform 5.0mm, from the mucosa level;
• Conicality 15°;
• Single screwed prosthesis (anti-rotational);
• Cylinders with screw;
• Slim Fit components, that minimize bone remotion of the
Countersink Drill, facilitating the intermediate seating and
the tissue accommodation.
Demonstrativesequenceof
SFConicalAbutmentExternalHex
Torque Connection 1.2
Conical SF Abutment Conical Abutment 4.3 mm
Conical Abutment 5.0 mm
Conical Torque Connection 4.1 mm
Conical Torque Connection 4.1 mm
Prosthetic Torque Ratchet Driver
Sequence 4.1 / 4.3 mm
Sequence 5.0 mm
Conical Micro Abutment 4.1 Transfer Conical Micro Abutment 5.0 Transfer
Conical Mini Abutment 4.1 Analogue Conical Mini Abutment 5.0 Analogue
Conical Mini AbutmentProtection 4.1 Cylinder
Conical Mini Abutment Protection 5.0 Cylinder
Prosthetic Torque Ratchet Driver
Conical Mini Abutment 4.1 Cylinder Conical Mini Abutment 5.0 Cylinder
Co
Cr/
Tili
te
Cas
tab
le
Cas
tab
le
Tita
niu
m
Tita
niu
m
Co
Cr/
Tili
te
20N.cm
69
Dem
onstrativesequenceof
SFConicalAbutm
ent
ExternalHex
Ø 4.1
Ø 5.0
PolishingProtectorofConicalAbutment
Ø 4.1
Ø 5.0
Anti-rotationalAnalogueofConicalAbutment
Ø 4.1
Ø 5.0
ProtectionCylinderofConicalAbutment
ConicalAbutmentTransfer
Ø 4.1
Ø 5.0
Ø 4.1
Ø 5.0
CylinderScrewofConicalAbutmentt
Titanium Neotorque
Neotorque
•Component with molding function by prosthesis construction;
• Available in Titanium;• For open tray technique;• Anti-rotational;• Select transfer according to the component to be molded, as prosthetic planning.
•Protector for cylinders during polishing and finishing of prosthesis;
• Use the corresponding screw to the component for fixation.
•Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
•Available in Titanium;• Used to protect the component during the prosthesis con-struction;
• Observe the compatible diameter with the prosthetic compo-nent;
• To installation, use Digital Driver 1.2mm (104.007).
• Available in Titanium;• Replica of prosthetic component platform;• For prosthesis construction or prosthetic planning.
Castable Titanium Tilite CoCr
ConicalAbutmentCylinder
Ø 4.1
Ø 5.0
•Observe corresponding sequence to the component diameter and indicated torque;
• For torque, use Conical Torque Connection 4.1mm (105.009), except for Ø 5.0 Torque Connection 1.6mm (105.006);
• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
•Anti-rotational for screwed unitary elements;• Observe the corresponding sequence to the component diameter;• Screw included;• To screw torque, use Torque Conection 1.2mm (105.005);• Observe indicated torque;• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
1mm 2mm
Ø 4.1
Ø 5.0
Ø 4.3
3mm
SFConicalAbutment
Sli
m F
it115.051 115.052 115.053
115.007 115.008 115.009
115.192 115.193 115.194
101.030
101.027
106.051
106.052
An
tiro
tati
on
al
An
tiro
tati
on
al
118.106 118.107 118.140 118.233
118.110 118.111 118.142
108.035
108.025
Open-tray
108.075
Closed-tray
123.013
123.014
116.004 116.231
116.005 116.232
70
Pro
sth
eti
cs
Co
mp
on
en
ts
Torque Connection 1.2
Torque Connection 1.2 mm
Prosthetic Torque Ratchet Driver
Sequence 3.3 / 4.1 / 4.3 mm
Sequence 5.0 mm
Mini Conical Abutment Analogue 4.1 Mini Conical Abutment Analogue 5.0
Protection Cylinder of the Conical Mini Abutment 4.1
Protection Cylinder of the Conical Mini Abutment 5.0
Prosthetic Torque Ratchet Driver
Micro Conical Abutment Transfer 4.1
Micro Conical Abutment Transfer 5.0
Angled
Mini Abutment
17º e 30º
20N.cm
Conical Mini Abutment 4.1 Cylinder Conical Mini Abutment 5.0 Cylinder
Cas
tab
le
Tita
niu
m
Go
ld /
Co
Cr
/ Ti
lite
Cas
tab
le
Tita
niu
m
Go
ld /
Co
Cr
/ Ti
lite
Conical Torque Connection
4.1 mm
SF Mini Conical Abutment 4.1 mm
32N.cm
Torque Connection 1.6 mm
SF Mini Conical Abutment 5.0 mm
32N.cm
•Available in Titanium;
• Minimum interocclusal space of 4.4mm on platform 4.1,
and 4.8mm on platform 5.0mm, from the mucosa level;
• Screwed and multiple prosthesis (rotational);
• Conicality 20°;
• Mini Conical Abutment presents 12 positions of fitting;
• The cylinders come with Neotorque screw, except the
castables, that comes with Titanium screw.
• Slim Fit components, that minimize bone remotion of the
Countersink Drill, facilitating the intermediate seating and
the tissue accommodation.
SFConicalMiniAbutmentDemonstrativesequenceof
ExternalHex
71
Ø 4.1
Ø 5.0 123.009
123.008
PolishingProtectorofMiniConicalAbutment
108.023 108.024
108.021 108.022 108.068
MiniConicalAbutmentTransfer
Short screw
Closed-tray Open-tray Multifunctional
116.036
Ø 4.1
Ø 5.0
•Component with moulding function for the making of the prosthesis;
•Available in Titanium; •For the open-tray technique (drag);•Rotational;•Select the transfer in accordance with the component to be moulded conforming to the planned prosthetics.
2mm
Ø 4.1
Ø 5.0
Ø 4.3
3mm 4mm 5mm
AngledMiniConicalAbutment
115.084 115.074 115.075
115.076 115.077 115.078
115.094 115.095 115.096
17º
•Minimum interocclusal space of 4.4mm on platform 4.1, and 4.8mm on platform 5.0mm, from the mucosa level;
• Screwed and multiple prosthesis (rotational);• Observe corresponding sequence to the component diameter;• Observe indicated torque;• For torque, use Torque Connection 1.2 (105.005);• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
118.112 118.113 118.146
118.114 118.115 118.147 118.240
Castable Titanium Tilite
118.206 118.209 118.210
Gold CoCrCoCr
Para solda
CylinderofMiniConical
Abutment
Ø 4.1
Ø 5.0
1mm 2mm
115.187 115.188
115.054 115.055 115.056 115.057 115.058
115.197 115.198 115.199
Ø 4.1
Ø 5.0
Ø 4.3
3mm 4mm
115.189 115.190
5mm
115.191
SFMiniConicalAbutment
Sli
m F
itS
lim
Fit
•Observe corresponding sequence to the component diameter and indicated torque;
• Observe indicated torque;• For torque, use Conical Torque Connection 4.1mm (105.009), except for Ø 5.0 Torque Connection 1.6mm (105.006);
• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Ø 4.1
Ø 5.0
106.054
106.055
ProtectionCylinderofMiniConicalAbutment
•Available in Titanium;•Used to protect the component during the prosthesis elaboration;
•Observe the compatible diametre with the prosthetic component;
•Use the Digital Driver 1.2mm (104.007) for installation.
Ø 4.1
Ø 5.0 101.022
101.020
AnalogueofMiniConicalAbutment
•Available in Titanium;•Replication of the prosthetic component;•For the making of the prosthesis and/or prosthetic planning.
•Rotational for screwed multiple elements;• Observe corresponding sequence to the component diameter;• To screw torque, use Torque Connection 1.2mm (105.005)• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Ø 4.1
Ø 5.0
CylinderScrewofMiniConicalAbutment
Titanium Neotorque
116.037 116.227
116.038 116.228
Neotorque
•Protector for cylinders during polishing and finishing of prosthesis;
• Use the corresponding screw to the component for fixation.
•Application of a thin carbon-based film which promotes reduced friction resulting in an increase in the preload.
Ø 4.1
Ø 5.0
Ø 4.3 115.111 115.112 115.113
115.143 115.144 115.145
115.140 115.141 115.142
30º
SFConicalMiniAbutm
ent
Dem
onstrativesequenceof
ExternalHex
72
Pro
sth
eti
cs
Co
mp
on
en
ts
4.5
3.8
Universal Post Transfer
Prosthetic Torque
Ratchet Driver
Universal Post
Neotorque Screw
Torque Connection 1.2
Universal Post Analogue
Universal Post Cylinder
Aluminum
Universal Post Cylinder
Temporary
Universal Post Cylinder
Castable
Ø4.5 Ø4.5 Ø4.5
Ø4.5
Ø4.5
32N.cm
4 ou 6
1, 2 ou 3 mm
UniversalPostDemonstrativesequenceof
ExternalHex
• Available in Titanium;
• Cemented prosthesis;
• The Universal Post can be prepared according to circunstances,
and, in this case, the prosthetic sequence can not be used;
• Compatible with platform 4.1 and 4.3 External Hex;
• Screw not included;
• Available in two heights: 4mm and 6mm
73
• Component with molding function by prosthesis construc-tion;
• Available in polymer;• For closed tray technique;• Anti-rotational;• Select transfer according to the component to be molded, as prosthetic planning.
1mm
4mm
4mm
4mm
4mm
2mm
6mm
6mm
6mm
6mm
Ø 4.5
Ø 4.5
Ø 4.5
Ø 4.5
3mm
UniversalPost
UniversalPostAnalogue
UniversalPostSet
• Available in Titanium;• Replica of prosthetic component;• For prosthesis construction and/or prosthetic planning.
• Components Kit of Universal Post line, containing the Transfer and Provisional / Castable Cylinders.
114.177 114.178 114.179
114.180 114.181 114.182
108.045
108.044
UniversalPostTransfer
101.041
101.040
108.062
108.063
• Available in:Provisional: for provisional prosthesis;Alumina: for “metal free” prosthesis;Castable: casting.• Cemented prosthesis;• Compatible with all Universal Posts, when not prepared.
4mm
6mm
Ø 4.5
118.188 118.183 118.194
118.189 118.184 118.195
TemporaryAluminium Castable
CylinderofUniversalPost
Ø 4.1
Ø 4.3
Neotorque
Neotorque Titanium
UniversalPostScrew
116.180 116.002
• Application of a thin pellicle with carbon basis, which promotes low friction coefficient, result-ing in pre-load increase.
UniversalPost
Dem
onstrativesequenceof
E xternalHex
74
Pro
sth
eti
c C
om
po
ne
nts
Torque Connection 1.2
Prosthetic Torque Ratchet Driver
Neotorque Screw Neotorque Screw Neotorque Screw Titanium Screw
Personalised Post 4.1 mm
Personalised Post 5.0 mm
Angled Post (17º e 30º)3.3/ 4.1/ 4.3 / 5.0 mm
Implant Analogue
Ø3.3 / Ø4.1 / Ø4.3 / Ø5.0 Ø3.3 / Ø4.1 / Ø4.3 / Ø5.0
Conical Transfer 3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm
Dragl Transfer 3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm
32N.cm
32N.cm
32N.cm
32N.cm
Slim Fit Post 4.1 mm
• Available in Titanium;
• Cemented prosthesis;
• Angled Post presents 12 positions of fitting;
• Customizable Post without screw. It is recommended to use the
Neotorque screw;
• Slim Fit components, that minimize bone remotion of the
Countersink Drill, facilitating the intermediate seating and the
tissue accommodation.
PostDemonstrativesequenceof
ExternalHex
75
Ø 3.3
Ø 3.3
Ø 4.3
Ø 4.3
Ø 4.1
Ø 4.1
Ø 5.0
Ø 5.0
•Component with molding function by prosthesis construction;•Available in Titanium;•Select transfer according to the implant to be molded, as prosthetic planning.
ImplantTransfer
108.012
Antirotational
Rotational
108.013
108.038
108.029
108.066
108.003
108.002
108.001
108.011
108.034
108.067
108.006
Open-trayClosed-tray
2mm 3mm
Ø 3.3
Ø 4.3
Ø 4.1
Ø 4.1
Ø 5.0
4mm 5mm
AngledPost
•Anti-rotational•Titanium screw included;•Observe indicated torque;•To torque, use Torque Connection 1.2mm (105.005);•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
114.025 114.026 114.027
114.016 114.017 114.018
114.049 114.050 114.051
114.071 114.072 114.073
17º
114.009 114.010 114.01130º
Ø 4.1
•To installation, use Torque Connection 1.2mm (105.005);•To unitary elements, select Neotorque Screw;•Screw not included;•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).
SlimFitPost
114.237
Antirotational
114.236
Rotational
Ø 3.3
Ø 4.3
Ø 4.1
Ø 5.0
ImplantAnalogue
101.002 101.001
Titanium Brass
101.004 101.003
101.028 101.024
101.006 101.005
•Available in Brass and Titanium;•Replica of implant platform;•For prosthesis construction and/or prosthetic planning.
Ø 4.1 for ø 5.0
Ø 4.1 for ø 6.0
Ø 5.0 for ø 6.0
•Available in Titanium;•Cemented prosthesis;•To installation, use Torque Connection 1.2mm (105.005);•To unitary elements, select Neotorque Screw;•Screw not included;•Observe indicated torque;•To torque control, use Prosthetic Torque Ratchet Driver (104.026).•Available to platform 4.1, 4.3 and 5.0 .
CustomizablePost
114.029
114.030
114.035
Ø 3.3
Ø 4.3
Ø 4.1
Ø 5.0
PostScrew
116.188 116.001
116.189 116.003
116.180 116.002
Neotorque
Neotorque Titanium
• Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
Post
Dem
onstrativesequenceof
ExternalHex
76
Co
mp
on
en
tes
Pro
téti
co
s
• Prosthetic component directly over the implant hex;
• For screwed or cemented prosthesis;
• Available in Rotational or Anti-Rotational;
- Tilite and CoCr: overcastting;
- Castable: casting;
- Titanium: Provisional or Cemented Prosthesis
- Gold: Overcasting with high melting range leagues. With Titanium
and Neotorque screw;
• Observe presentation with screw;
• For unitary elements, select Neotorque screw.
UCLA
Analogue3.3 mm
Analogue4.1 mm
Analogue4.3 mm
Analogue5.0 mm
UCLA3.3 mm
UCLA4.1 mm
UCLA4.3 mm
UCLA5.0 mm
Torque Connection 1.2
Prosthetic Torque
Ratchet Driver
32N.cm
Neotorque Screw
Ø3.3 / Ø4.1 / Ø4.3 / Ø5.0 Ø3.3 / Ø4.1 / Ø4.3 / Ø5.0
Closed-tray Transfer
3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm
Open-tray Transfer
3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm
Demonstrativesequenceof
ExternalHex
77
SDem
onstrativesequenceof
UCLA
ExternalHex
108.011
108.034
Ø 3.3
Ø 3.3
Ø 4.3
Ø 4.3
Ø 4.1
Ø 4.1
Ø 5.0
Ø 5.0
•Component with molding function by prosthesis construction;•Available in Titanium;•Select transfer according to the implant to be molded, as prosthetic planning.
•Zirconia Line with and without a Titanium base.
ImplantTransfer
108.012
Antirotational
Rotational
108.013
108.038
108.029
108.066
108.003
108.002
108.001
108.067
108.006
Open-trayClosed-tray
116.003
116.002
116.001Ø 3.3
Ø 4.3
Ø 4.1
Ø 5.0
UCLAScrew
116.188
116.189
116.180
Neotorque Titanium
Ø 3.3
Ø 4.3
Ø 4.1
Ø 5.0
ImplantAnalogue
101.002
Titanium
101.001
Brass
101.004 101.003
101.028 101.024
101.006 101.005
•Available in Brass and Titanium;•Replica of implant platform;•For prosthesis construction or prosthetic planning.
Ø 3.3
Ø 4.3
Ø 4.1
Ø 5.0
123.004
123.005
123.002
123.003
PolishingProtector
• Protector for cylinders during polishing and finishing of prosthesis;
• Use the corresponding screw to the component for fixation.
Ø 3.3
Ø 3.3
Ø 4.3
Ø 4.3
Ø 4.1
Ø 4.1
Ø 5.0
Ø 5.0
UCLA
Antirotational
Rotational
118.204
118.097
118.009
118.040118.029 118.219
118.027 118.243
118.121 118.217 118.244
118.079 118.215118.212
118.235
118.237 118.006
118.101
118.004
118.001
CastableTilite Zirconia
Zirconia with Titanium
belt Cobalt-Chrome (Cocr)
118.008
GoldTitanium
118.205
118.152
118.030
118.028
118.026
118.120
118.078118.211
118.234
118.236 118.007
118.119
118.005
118.002
Neotorque• Application of a thin pellicle with carbon basis, which promotes low friction coefficient, result-ing in pre-load increase.
78
Pro
sth
eti
c C
om
po
ne
nts
• Available in Titanium;
• Directly over the implant;
• It´s recommended capture the components in
patient’s mouth, one by one;
• O’ring with protection disc;
• Application of Nitride Titanium coating for increased
the wear resistance;
• See the demonstrative sequence of Mini Ball
Attachment on page 131.
InstalledBallAttachment
Mini Ball Attachment
4.1
Mini Ball Attachment
4.3
Mini Ball Attachment
5.0
Conical Torque Connection 4.1
Prosthetic Torque Ratchet Driver
Positioner straight
Positioner 7º
Positioner14º
O’ring with cylinder
Protection Disc
32N.cm
MiniBallAttachmentDemonstrativesequenceof
ExternalHex
79
102.060 102.061 102.062 102.093
102.063 102.064 102.065 102.094
102.066 102.067 102.068 102.095
MiniBallAttachment
2mm
Ø 4.1
Ø 4.3
Ø 5.0
3mm 4mm 5mm
• To installation, use Conical Torque Connection 4.1mm (105.009);
• Observe indicated torque;• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
straignt,7ºe14º
CastableAttachmentBall
Positioners
•Castable: casting in various metals;•May be cemented in natural roots or waxed in bars for overdenture retention.
•Available in polymer;•Indicated to define the correct distance between Attachment Ball components and O’ring with cylinder;•Corrects the parallelism between implants;•Essential for O’ring capturing.
102.078
102.076
102.073
102.077
O’ringwithcylinder
O’ring
ProtectionDisk
102.075O’ringRemover
O’ringMount
104.044
104.043
• Digital Driver with function of O’ring replacing to the cylinder.
• Digital Driver with function of O’ring placement to the cylinder.
• Available in Titanium (cylinder);• Available in polymer (O’ring);• Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;
• Not autoclavable.
• Available in polymer (O’ring);• Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;
• Not autoclavable.
• Package with 10 units.
MiniBallAttachm
ent
Dem
onstrativesequenceof
ExternalHex
80
I n t e r n a l H e x
81
•Prostheticcomponentswithreducedplatformin
relationtotheimplant(SwitchingPlatform);
•Installationdriverwithtweezerstoincreasethe
transportsecurityandtheimplantplacement;
•Cervicalmicroretentionstobonetissue
maintenance;
•Uniqueprostheticsequenceindependentofthe
implantplatformdiameter.
INTERNALHEX
Inte
rnal
Thr
ead
Ø 1
.6
• Mini Conical Abutment II Plus (multiple);
• UCLA Tilite II Plus (unitary);• UCLA CoCr II Plus (unitary);• UCLA Zirconia II Plus• Conical Abutment II Plus
• Universal Post II Plus• Angled Post II Plus 17°
and 30°• UCLA Tilite II Plus• UCLA CoCr II Plus (unitary)• UCLA Zirconia II Plus
•Mini Ball Attachment II Plus •Clip Bar
• Mini Conical Abutment II Plus
• UCLA Tilite II Plus• UCLA CoCr II Plus
(unitary).
• Mini Conical Abutment II Plus;
• Cylinder and Distal External Bar.
Passive Fitting Technique • Cylinder - Castable Mini
Abutment• Cylinder – Titanium Mini
Abutment • Cylinder – Brass Mini
Abutment
3.75,4.3e5.0mm
4.3e5.0mm
ImplantDiameter
ProstheticPlatformDiameter
ScrewedProsthesis
CementedProsthesis Overdenture Protocol
PlatformDiameter
2.5mm
HEXAGON
2.6mm
82
Imp
lan
ts
ProductCharacteristics
Prosthetic Components with
reduced platform in relation
to the implant (Switching
Platform).
• Cylindrical implant with Internal Hex interface;
• NeoPoros Surface;
• Double thread (faster installation and less trauma);
• High cutting capacity;
• Suitable for bones type I and II;
• Cover screw not included;
• Unique prosthetic interface for all implant diameters;
• Perforation rotation: 800-1200 rpm;
• Installation rotation: 30 rpm;
Drillsequence
3.75mm
5.0mm
Init
ial
Dri
ll
Tita
max
Dri
ll 2
.0
Pil
ot
2/3
Tita
max
Dri
ll 3
.0
Pil
ot
3/3
.75
Tita
max
Dri
ll 3
.15
Co
un
ters
ink
II 4
.3
Tita
max
Dri
ll 3
.8
Tita
max
Dri
ll 4
.3
Co
un
ters
ink
II 5
.0
Optional
5.0
3.8
83
11.0 mm9.0 mm7.0 mm 13.0 mm 15.0 mm
Ø 3.75
(4.3)
Ø 5.0
109.462 109.463 109.464 109.465 109.466
109.474 109.475 109.476 109.477
Coverscrew
117.014
Healings
5.0 mm4.0 mm3.0 mm2.0 mm
106.176 106.177 106.178 106.179
84
Imp
lan
ts
ProductCharacteristics:
• Conical implant with Internal Hex interface;
• NeoPoros Surface;
• Suitable for bones type III and IV and pos-extracting
installation;
• Cover screw not included;
• Unique prosthetic interface for all implant diameters;
• Perforation rotation: 500-800 rpm;
• Installation rotation: 30 rpm;
4.3mm
5.0mm
Init
ial
Dri
ll
Alv
im D
rill
2.0
Alv
im D
rill
3.5
Alv
im D
rill
4.3
Co
un
ters
ink
II 4
.3
Bro
ca A
lvim
5.0
Co
un
ters
ink
II 5
.0
Optional
Drillsequence
Prosthetic Components with
reduced platform in relation
to the implant (Switching
Platform).
5.0
3.8
85
Ø 4.3
Ø 5.0
10.0 mm 13.0 mm 16.0 mm
109.478 109.479 109.480
109.481 109.482 109.483
Coverscrew
Healings
117.014
5.0 mm4.0 mm3.0 mm2.0 mm
106.176 106.177 106.178 106.179
86
Pro
sth
eti
c C
om
po
ne
nts
DemonstrativeSequenceof
ConicalAbutmentIIPlusInternalHex
Torque Connection 1.2mm
Prosthetic Torque Ratchet
Driver
Conical Torque Connection 4.1 mm
Conical Abutment II Plus
Prosthetic Torque Ratchet Driver
Conical Abutment Transfer 4.1
Conical Abutment
Analogue 4.1
Protection Cylinder of Conical Mini Abutment 4.1
Conical Abutment Cylinder 4.1
Cas
tab
le
Tita
niu
m
Tili
te /
Co
Cr
20N.cm
•Available in Titanium;
• Minimum interocclusal space of 6.1mm from the mucosa
level;
• Conicality 15°;
• Single screwed prosthesis (anti-rotational);
• Concept Switching Platform;
• Compatible components with implants diameter (Ø 3.75,
Ø 4.3 and Ø 5.0);
• The cylinders come with Neotorque screw, except the
castables, that comes with Titanium screw.
87
106.051
ProtectionCylinderofConicalAbutment
108.035
108.020
108.075
108.018
101.027
123.013
ConicalAbutmentAnalogue
Open tray Closed tray
Titanium Neotorque
116.004 116.231
Castable
Anti-rotational
Rotational
Anti-rotational
Rotational
Titanium Tilite CoCr
CylinderofConical
AbutmentIIPlus
1.0mm 2.0mm
ø4.1
ø4.1
ø4.1
ø4.1
ø4.1
2.0mm 3.0mm3.0mm 4.0mm
ConicalAbutmentIIPlus
AngledConicalAbutmentIIPlus17°
115.184115.203
115.185115.204
115.186115.205
118.106
118.104
118.107
118.105
118.233
118.232
118.140
118.139
• For torque, use Conical Torque Connection 4.1mm;• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
• To torque, use Conical Torque Connection 4.1mm;• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
•Available: -Titanium: Provisional prosthesis; -Tilite and CoCr: Overcasting; -Castable: Casting. •Anti-rotational for unitary screwed elements;• Screw included;• To screw torque, use Torque Connection 1.2mm (105.005);• Observe indicated torque;• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
• Available in Brass and Titanium;• Replica of implant platform or prosthetic component;• For prosthesis construction or prosthetic planning.
• Available in Titanium;• Used to protect the component during the prosthesis construction;
• Observe the compatible diameter with the prosthetic component;
• To installation, use Digital Driver 1.2mm (104.007).
• Component with molding function by prosthesis construction;• Available in Titanium;• For open tray or closed tray technique;• Rotational and Anti-rotational;• Select transfer according to the component to be molded, as prosthetic planning.
ConicalAbutmentTransfer
PolishingProtectorofConicalAbutment
CylinderScrewofConicalAbutment
•Protector for cylinders during polishing and finishing of prosthesis;
•Use the corresponding screw to the component fixation.
ConicalAbutm
entIIPlus
Dem
onstrativesequenceof
InternalHex
Neotorque• Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
88
Pro
sth
eti
c C
om
po
ne
nts
DemonstrativeSequenceof
MiniConicalAbutmentIIPlusInternalHex
Mini Conical Abutment II Plus
Conical Torque
Connection 4.1 mm
Prosthetic Torque Ratchet Driver
Multifunctional Mini Conical Abutment
Transfer
Mini Conical Abutment Transfer
Mini Conical Abutment Analogue
Protection Cylinder of Mini Conical Abutment
Mini Conical Abutment Cylinder
Tita
niu
m
Cas
tab
le
Torque Connection 1.2mm
Prosthetic Torque Ratchet Driver
Go
ld /
Til
ite
/ C
oC
r
20N.cm
• Available in Titanium;
• Minimum interocclusal space of 4.4mm from the
mucosa level;
• Screwed and multiple prosthesis (rotational);
• Conicality 20°;
• Concept Switching Platform;
• Compatible component with implants diameter II Plus
(Ø 3.75, Ø 4.3 and Ø 5.0);
• The cylinders come with Neotorque screw, except the
castables, that comes with Titanium screw.
89
Ø 4.1 123.008
PolishingProtectorofMiniConicalAbutment
118.112 118.113 118.146
Castable Titanium Tilite
118.063 118.209 118.210
Gold CoCrCoCr for welding
CylinderofMini
ConicalAbutment
Ø 4.1
115.155
1mm 2mm
115.156 115.157 115.158 115.159
3mm 4mm 5mm
MiniConicalAbutmentIIPlus
• Observe indicated torque;• To torque, use Conical Torque Connection 4.1mm (105.009);• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Ø 4.1 106.054
ProtectionCylinderofMiniConicalAbutment
• Available in Titanium;• Used to protect the component during the prosthesis construction;• Observe the compatible diameter with the prosthetic component;• To installation, use Digital Driver 1.2mm (104.007).
Ø 4.1 101.020
MiniConicalAbutmentAnalogue
• Available in Titanium;• Replica of prosthetic component platform;• For prosthesis construction and prosthetic planning.
• Protector for cylinders during polishing and finishing of prosthesis;
• Use the corresponding screw to the component for fixation.
•Available in: -Titanium: prosthesis; -Tilite and CoCr: overcastting; -Castable: casting; -Gold alloy: overcastting with high melting range leagues.• Titanium and Neotorque screws included;• Rotational for screwed multiple elements;• To screw torque, use Torque Connection 1.2mm (105.005);• Observe indicated torque;• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
Ø 4.1
CylinderScrewofMiniConicalAbutmentTitanium Neotorque
116.037 116.227
ConicalM
iniAbutm
entIIPlus
Dem
onstrativeSequenceof
InternalHex
Neotorque•Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
116.036
ø4.1 108.022108.021 108.068
MiniConicalAbutmentTransfer
Open tray Closed tray
Screw Short
Multifunctional
•Available in Titanium;•Component with molding function by prosthesis construction;•For open tray or closed tray technique;•Rotational;
90
Pro
sth
eti
c C
om
po
ne
nts
Demonstrativesequenceof
UniversalPostIIPlusInternalHex
20N.cm
Universal Post Transfer
Prosthetic Torque Ratchet Driver
Universal Posthigh 4.0 mm
Universal Posthigh 6.0 mm
Neotorque Screw
Torque Connection 1.2
Universal Post Analogue
Universal Post Cylinder
Aluminium
Universal Post Cylinder
Provisional
Universal Post Cylinder
Castable
Ø4.5 Ø4.5
Ø4.5
Ø4.5
Ø4.5
•Available in Titanium;
•Cemented prosthesis;
•Screw not included;
•The Universal Post can be prepared according to circunstances,
and, in this case, the prosthetic sequence can not be used;
•Compatible component with implants diameter II Plus (Ø 3.75,
Ø 4.3 and Ø 5.0);
ø3.8
ø4.5
4 ou 6
Transmucous
91
• Component with molding function by prosthesis construction;
• Available in polymer;• For closed tray technique;• Anti-rotational;• Select transfer according to the component to be molded, as prosthetic planning.
1mm4mm
4mm
4mm
4mm
2mm6mm
6mm
6mm
6mm
Ø 4.5
Ø 4.5
Ø 4.5
Ø 4.5
3mm
UniversalPost
• To installation, use Torque Connection 1.2mm (105.005);• For unitary elements, select Neotorque screw.• Observe indicated torque;• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
• Available in two heights of cemented area: 4mm and 6mm.
UniversalPostAnalogue
UniversalPostSet
•Available in Titanium;•Replica of prosthetic component;•For prosthesis construction and prosthetic planning.
•Components Kit of Universal Post line, containing the Transfer and Provisional / Castable Cylinders;
114.123 114.124 114.125
114.126 114.127 114.128
108.045
108.044
UniversalPostTransfer
101.041
101.040
108.062
108.063
•Available in: -Provisional: for provisional prosthesis; -Alumina: for “metal free” prosthesis; -Castable: casting.•Cemented prosthesis; •Compatible for all Universal Posts, when not prepared.
4mm
6mm
Ø 4.5
118.188 118.183 118.194
118.189 118.184 118.195
Temporary Alumina Castable
CylinderofUniversalPost
Neotorque Titanium
UniversalPost
ScrewIIPlus
116.228 116.002
UniversalPostIIPlus
Dem
onstrativeSequenceof
InternalHex
Neotorque•Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
92
Pro
sth
eti
c C
om
po
ne
nts
DemonstrativeSequenceof
AngledPostIIPlusInternalHex
•Available in Titanium;
•Cemented prosthesis;
•Anti-rotational;
•Titanium screw included.
Prosthetic Torque Ratchet Driver
Torque Connection 1.2mm
Angled Post II Plus
Transfer
II Plus
Analogue II Plus
20N.cm
20N.cm
93
2mm 3mm
Ø 4.3
Ø 5.0
4mm 5mm
AngledPostIIPlus
•Component with molding function by prosthesis construction;•For open tray or closed tray technique.
114.171 114.172 114.17317º
114.174 114.175 114.17630º
AnalogueIIPlus
101.032
101.034
ImplantTransfer
Antir-otacional
108.046 108.047
Open TrayClosed Tray
•Available in Brass;• Replica of implant platform;• For prosthesis construction and prosthetic planning.
• Observe indicated torque;• To torque, use Torque Connection 1.2mm (105.005);• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
AngledPostIIPlus
Dem
onstrativeSequenceof
InternalHex
94
Pro
sth
eti
c C
om
po
ne
nts
Demonstrativesequenceof
UCLAIIPlusInternalHex
Transfer II Plus
Analogue II Plus
UCLA II Plus UCLA II Plus UCLA II Plus
CoCr
Tilite
Titanium 20
N.cm
Torque Connection 1.2
Prosthetic Torque Ratchet Driver
Neotorque Screw
•Directly over the implant;
•Screwed or cemented prosthesis;
•Multiple or unitary elements;
•Available in:
-Tilite and CoCr: overcastting;
-Titanium: provisional or cemented prosthesis;
•Screw not included;
•For unitary elements, select Neotorque screw.
95
UCLAIIPlus
Anti-rotational
Rotational
118.190 118.214
118.213
Tilite CoCr
118.185
Titanium
116.224Ø 4.1
ScrewIIPlus
116.226
Neotorque Titanium
Ø 4.3
ImplantAnalogueIIPlus
101.032
•Available in Brass;•Replica of implant platform;•For prosthesis construction and prosthetic planning.
•Component with molding function by prosthesis construction;•Available in Titanium;•For open tray or closed tray technique;•Anti-rotational;
ImplantTransfer
Anti-rotacional
108.046 108.047
Closed trayOpen tray
UCLAIIPlus
Dem
onstrativeSequenceof
InternalHex
Neotorque• Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.
96
Pro
sth
eti
c C
om
po
ne
nts
DemonstrativeSequenceof
MiniBallAttachmentIIPlusInternalHex
Mini Ball Attachment II Plus
• Available in Titanium;
• Directly over the implant;
• It´s recommended capture the components in patient’s
mouth, one by one;
• Application of Nitride Titanium coating for increased the
wear resistance;
• O’ring with protection disc;
• See the demonstrative sequence on page 131.
Conical Torque Connection
4.1
Prosthetic Torque Ratchet Driver
PositionerStraight
Positioner7º
Positioner14º
O’ring with Cylinder
Protection Disc
32N.cm
BallAttachmentInstalled.
97
102.078
102.090 102.091 102.092 102.096
MiniBallAttachmentIIPlus
2mm 3mm 4mm 5mm
Straight, 7º e 14º
Positioners
102.073
102.077
O’ringwithCylinder
O’ring
ProtectionDisc102.075
O’ringRemover
O’ringMount
104.044
104.043
• To installation, use Conical Torque Connection 4.1mm (105.009);
• Observe indicated torque;• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
• Digital Driver with function of O’ring replacing to the cylinder.
• Digital Driver with function of O’ring placement to the cylinder.
•Package with 10 units.
• Available in polymer;• Defines the correct distance between Attachment Ball and O’ring;
• Essential for O’ring capturing.• Corrects the parallelism between implants;
• Cylinder in Titanium;• O’ring in polymer;• Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;
• Not autoclavable.
• Available in polymer (O’ring);• Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention;
• Not autoclavable.
MiniBallAttachm
entIIPlus
Dem
onstrativeSequenceof
InternalHex
CastableAttachmentBall
•Castable: Casting in various metals;•May be cemented in natural roots or waxed in bars for overdenture retention.
102.078
98
T r a n s g i n g i v a l
99
•SLIMFITProfile:Facilitatestheproceduresofsofttissues
synthesis(suture)bytheincreasingoftaperabutment;
•Unitarybody:highermechanicalstrength;
•Stabiliserscrewofprosthesiswithlargerdiameter(2mm);
•Highresistancetoinsertiontorque;
•Reductionofworkingtime;
•NeoporosSurfacetreatment;
•Usedforsinglestagesurgery;
•Suitableforinferiorprotocoltechnique;
•WorkcanbemadewithfewernumberofImplants.
TRANSGINGIVAL
Inte
rnal
Scr
ew Ø
2.0
3.75,4.0e4.5mm
•Castable GT Cylinder •Tilite GT Cylinder •Titanium GT Cylinder •CoCr GT Cylinder
•Clip Bar •Castable GT Cylinder
•Cylinder and Distal Extension Bar•Neopronto Technique
Passive Fitting Technique •Castable GT Cylinder•Titanium GT Cylinder•Brass GT Cylinder
ScrewedProsthesis
CementedProsthesis Overdenture Protocol
Ø4.8mm
2.6mm
3.0mm
100
Imp
lan
ts
ProductCharacteristics
• Cylindrical implant;
• Unitary body;
• NeoPoros Surface;
• Double thread (faster installation and less trauma);
• Suitable for inferior protocol;
• Prosthetic component integrated to the implant;
• Emergency profile that facilitates tissue accommodation
(Slim Fit);
• Transmucosa height 3mm;
• Perforation rotation: 800-1200 rpm;
• Installation rotation: 30 rpm;
3.75mm
4.0mm
4.5mm
Init
ial
Dri
ll
Tita
max
Dri
ll 2
.0
Pil
ot
Dri
ll 2
/3
Tita
max
Dri
ll 3
.0
Tita
max
Dri
ll 3
.15
Tita
max
Dri
ll 3
.3
Pil
ot
Dri
ll 3
/3.7
5
Tita
max
Dri
ll 3
.8
Drillsequence
Optional
101
109.345
109.455
109.346
109.456
109.347
109.457
109.348
109.458
109.341
109.355
109.342
109.356
109.343
109.357
109.344
109.358
11.0 mm
11.0 mm
13.0 mm
13.0 mm
15.0 mm
15.0 mm
17.0 mm
17.0 mm
109.337
109.351
109.338
109.352
109.339
109.353
109.340
109.354
Ø 3.75
Ø 3.75
Ø 4.0
Ø 4.0
Ø 4.5
Ø 4.5
102
Ne
op
ron
to
Advantages:
•Fast treatment;
•Reduced cost;
•Easy technique and practicality;
•Prosthetic bar prefabricated in Titanium;
•Definitive prosthesis;
•Guided surgery;
•Mandibular protocol.
•It´s a system for inferior protocol surgery, guided
with prefabricated bars;
• Case in autoclavable polymer;
• Driver, connections and surgical instruments re-
quired to Neopronto technique;
• Specific technique with GT Implants.
ProductCharacteristics
103
Neopronto Surgical Kit Case
Initial Drill Plus
Neopronto Drill 2.0 Plus
Neopronto Drill 3.0 Plus
Neopronto Drill 3.3 Plus
Neopronto Drill 3.8 Plus
Neopronto Drill Guide 2.0
Neopronto Drill Guide 3.0
Neopronto Drill Guide 3.3
Neopronto Drill Guide 3.8
Neopronto Bone Tap 3.75
Neopronto Bone Tap 4.0
Neopronto Bone Tap 4.5
Neopronto Implant Mount
Short Digital Driver 1.2
Hex Connector for Short Ratchet
Hex Connector for Contra-angle
Surgical Torque Ratchet
Titanium Tweezers
Neopronto GT Surgical Bar
Neopronto Surgical Guide Pin
Neopronto Surgical Guide
Neopronto Parallel Indicators
110.145
103.170
103.175
103.176
103.177
103.178
125.018
125.019
125.020
125.021
111.026
111.027
111.028
113.021
104.007
105.001
105.002
104.027
129.001
125.025
125.010
125.009
128.014
1
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
2
1
3
ItemscontainedintheNeoprontoSurgicalKit
104
1 2 3
4 5 6
7 8 9
Surgical Guide for the Neopronto Bar positioned over the ridge, with demarcation of the distal oblique incisions.
Osteotomy of the alveolar ridge. Surgical Guide for the Neopronto Bar positioned over the ridge, to evaluate the disposition of the implants.
Margin of safety from the distance of distal Implants in relation to the mentual emergencies with flags of 7 mm.
Stabilization of Surgical Guide for Neopronto Bar with guide pin and drilling with graft drill of 1.6 mm.
Neopronto Surgical Bar fixing with graft screws of 2.0 x 12 mm.
Positioning of Drill Guide 2 mm and drilling with respective drill. Observe double irrigation.
Implants installation. Observe the mounters seating over the Neopronto Surgical Bar.
Surgical Bar removed and GT Implants installed.
105
10 11 12
13 14 15
16 17 18
Placement of Multifunctional Guide between the arches to re-establish the intermaxillary relations and make the union with acrylic resins and the transfers. After union, fluid silicon is injected to the soft tissue impression.
Transfers union with acrylic resin.Suture completed.
Protection Cylinders installation. See the Multifunctional Guide.
Observe the difference between the laboratorial work screw for cementing cylinder and the Neopronto Prosthetic Bar Screw.
Installation of Neopronto Prosthetic Bar over the Titanium cylinders and mounting in the articulator.
Cemented titanium cylinders in Neopronto Prosthetic Bar.
Final intraoral frontal view.
106
NeoprontoSurgicalGuide
• Allows the osteotomy planning in Neopronto cases or in Conventional Protocol cases;
• Assists in implant position planning (relation of distal implants with mentuals emergencies);
• Guide the perforations for Neopronto Surgical Bar fixing.
NeoprontoDrillGuide
• Attachment on Neopronto Surgical Bar to guide perforations;
• With screw to fix Neopronto Surgical Bar;• Observe drill sequence according to the implant.
PinforNeoprontoSurgicalGuide
• Stabilizes the Surgical Guide for Neopronto Bar.
125.009
125.018 ø2.0
125.019 ø3.0
125.020 ø3.3
125.021 ø3.8
125.010
107
128.014
NeoprontoParallel
IndicatorNeoprontoBoneTap
NeoprontoSurgicalBar
• Available in Titanium;• Chambers system for irrigation;• Lower perforations to bar fixing with graft screws 2.0mm;• Higher perforations to Drill Guide and GT Implant installation (with mount);
• For better adaptation to the bone, use Neopronto Surgical Guide.
125.025
NeoprontoProstheticBar
• Available in Titanium;• Prefabricated structure for Neopronto protocol prosthesis;
• May be desgasted conform required and would be cemented over the specific Titanium cylinders for Neopronto technique.
125.002
•Available in Titanium;• Forms the first threads to guide the implant during the installation.
• Available in Titanium;• Direction guides to implants installation, in relation to the antagonist.
111.026
3.75mm
111.027
4.0mm
111.028
4.5mm
108
NeoprontoDrillPlus
• Available in surgical stainless steel;• Twist Drill for Ø2.0mm and tri-spade to anothers diam-eters;
• Markings from 9 to 17mm.
103.175
ø2.0mm
103.176
ø3.0mm
103.177
ø3.3mm
103.178
ø3.8mm
NeoprontoProstheticBarScrew
• Final fixing of protocol prosthesis;• Torque of 20 N.cm;• To torque, use Torque Connection 1.2mm (105.005);• To torque control, use Prosthetic Torque Ratchet Driver (104.026).
116.157
NeoprontoMount
•Available in Titanium;•Specific for GT Implant installation in the Neopronto Technique.
113.021
GTOpenTrayTransfer
• Available in Titanium;• Torque screw included to use with multifunctional guide;
• Rotational for protocol.
108.010
GTAnalogue
•Available in Titanium;•GT Implant replica;•For prosthesis construction or prosthetic planning.
101.037
DRILLSPLUS:Count with the application of a thin pellicle with carbon basis, which promotes low friction coefficient and reduction of the heat generated on osteotomy.
109
NeoprontoCylinder
WorkScrew
• Available in Titanium;• Its function is the union of Prosthetic Bar to the model during the prosthesis construction.
116.087
ø5.0mm
GTProtectionCylinder
• Available in Titanium;• Protect the GT Implant Abutment during the prosthesis confeccion;
• To installation, use Digital Driver 1.2 (104.007).
106.102
CylinderforcementingoftheNeoprontoBar
• Available in Titanium;• Allows prosthesis passivity;• Cemented before waxing;• Screw included only for cementation.
118.013
GTPassiveFittingCylinder
• Cylinders to use the Passive Fitting technique with casted structure over the GT Implants.
118.174 118.173 118.172
Castable Brass Titanium
•Use Driver 1.2.
NeoprontoCylinderScrew
116.038
Observation:Aftertheimplantsinstallation,ifthereisnopassive
fittingfoProstheticBar,isindicatedusethecylindersfromthe
PassiveFittingTechnique(describedonSurgicalTechniquesbook).
Observation:Aftertheimplantsinstallation,ifthereisnopassive
fittingfoProstheticBar,isindicatedusethecylindersfromthe
PassiveFittingTechnique(describedonSurgicalTechniquesbook).
110
Z y g o m a t i c
111
Zy
go
ma
tic
112
Imp
lan
ts
ProductCharacteristics:
• Cylindrical implant;
• Morse Taper interface, with different dimensions of the conventional
implants (same dimensions of WS Titamax Implant) or External Hex
4.1mm;
• Smooth surface;
• Pre-mounted;
• Cover screw not included;
• Double thread in CM Zygomatic version;
• It is indicated to use the Transepithelial Abutment according to the
prosthetic interface.
Observation: This technique requires specificaccreditation.
Informationonwww.neodent.com.br
Ø 4.4mm
Nom
inal
Len
gth
Ø 3.9mm
Hex2.7m
mØ4.1mm
0.7mm
ø3.0mm
113
ZygomaticCMCoverScrew
117.016
30.0 mm 35.0 mm 40.0 mm 45.0 mm 47.5 mm 50.0 mm 52.5 mm
109.522 109.523 109.524 109.525 109.526 109.527 109.528
ExternalHexCoverScrew
30.0 mm 35.0 mm 40.0 mm 45.0 mm 47.5 mm 50.0 mm 52.5 mm
109.460 109.450 109.451 109.452 109.461 109.453 109.454
117.018
4.1
ExternalHex
MorseTaper
114
Pro
sth
eti
c C
om
po
ne
nts
Demonstrativesequenceof
TransepithelialZygomaticAbutment
External HexTransepithelial Abutment
Morse TaperTransepithelial Abutment
Conical Torque Connection 4.1mm
Transfer
Transepithelial Abutment Analogue
Protection Cylinder of Transepithelial Abutment
Torque Connection 1.2mm
Prosthetic Torque Ratchet Driver
Prosthetic TorqueRatcht Driver
20N.cm
•Available in Titanium;
•Minimum interocclusal space of 4.5mm;
•Screwed and multiple prosthesis;
•Exclusive for Zygomatic Implants;
•Machined cylinder in Tilite and CoCr for overcastting and
castable for casting.
Transepithelial Abutment Cylinder
TiliteCoCrCastable
32N.cm
115
Transepithelial
Dem
onstrativesequenceof
ZygomaticAbutm
ent
•Morse Taper Model compatible with WS Titamax.
MorseTaperTransepithelialAbutment
TransepithelialAbutmentCylinder
Castable CoCr Tilite
118.034 118.254 118.150
• Castable: casting;• Tilite: overcastting in Tilite (screw included);• CoCr: overcasting in various metals (screw included).
CylinderScrew
116.004
TransepithelialAbutmentOpenTrayTransfer
108.026
• Available in Titanium;• Open Tray:• Rotational.
TransepithelialAbutmentAnalogue
101.018
• Brass;• Transpithelial abutment replica;• For prosthesis construction or prosthetic planning.
ProtectionCylinderofTransepithelialAbutment
106.056
• Available in Titanium;• Suitable to protect the component in mouth during the prosthesis elaboration;
• To installation, use Digital Driver 1.2mm (104.007).
115.023 115.024 115.025 115.026
ExternalHexTransepithelialAbutment
3mm 4mm 5mm 6mm
115.172 115.173 115.174 115.175
3mm 4mm 5mm 6mm
116
Zy
go
ma
tic
K
it
ProductCharacteristics:
• Case in autoclavable polymer;
• Drills and connections for Zygomatic Implants –
External Hex and Morse Taper;
• Insert not included (KAVO).
Observation: This technique requires specificaccreditation.
Informationonwww.neodent.com.br
117
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
110.214
104.042
105.067
105.069
103.190
103.191
103.192
103.193
103.197
103.208
128.016
124.004
129.011
129.012
104.007
104.039
Zygomatic Surgical Kit Case
Zygomatic Installation Driver
Zygomatic Contra-Angle Connection
Connection for exchange of Zygomatic Drills
Zygomatic Spherical Drill 2.9 Plus
Zygomatic Twist Drill 2.7 Plus
Zygomatic Pilot Twist Drill 2.7/3.3 Plus
Zygomatic Twist Drill 3.3 Plus
Zygomatic Countersink Drill CM Plus
Zygomatic Pilot Twist Drill 3.3/3.7 Plus
Zygomatic Height Measurer CM
Zygomatic Labial Protector
Zygomatic Bicortal Probe
Zygomatic Probe
Short Digital Driver 1.2
Short Digital Driver 0.9
ItemscontainedinZygomaticKit
* •Illustrative photo
118
S u r g i c a l T e c h n i q u e s
119
Su
rg
ica
l T
ec
hn
iqu
es
120
Su
rgic
al
Te
ch
niq
ue
s
•Specific composition for the technique;
•Case in autoclavable polymer;
•Drivers, connections and surgical instruments
necessary to the Neoguide technique;
• Technique suitable for virtual planning and
flapless surgery.
Obs.:Thistechniquerequiresspecificaccreditation.
Informationonwww.neodent.com.br
•Case in autoclavable polymer
•Instruments for use of the technique, only with CM
Implants with diameter of 3.5 mm in reduced prosthetic
spaces (mesio-distal);
•Supplement to Neoguide Kit;
•The Narrow Neoguide technique does not use the
implant insertion guide.
CharacteristicsofNeoguideKit CharacteristicsofNarrowNeoguideKit
121
ItemsincludedinNeoguideSurgicalKit
Neoguide Surgical Kit Case
Neoguide Rotatory Punch
Neoguide Manual Punch
Neoguide Lance Drill
Neoguide Drill 1.3
Neoguide Drill 2.0
Neoguide Drill 2.8
Neoguide Drill 3.0
Neoguide Drill 3.3
Neoguide Pilot Drill 3.5
Neoguide Pilot Drill 3.75
Neoguide Pilot Drill 4.0
Hex Connector for Contra-angle
Hex Connector for Short Ratchet
Short Digital Driver 1.2
Digital Driver for Torque Connectors
Driver for Neoguide Mount
Neoguide Drill Guide 2.0
Neoguide Drill Guide 2.8
Neoguide Drill Guide 3.0
Neoguide Drill Guide 3.3
Neoguide Guide Clamp
Neoguide Mount 3.5
Neoguide Mount 3.75
Neoguide Mount 4.0
Surgical Torque Ratchet
Titanium Tweezers
Implant Guide 3.5
Implant Guide 3.75
Implant Guide 4.0
110.220
103.180
103.181
103.182
103.179
103.183
103.184
103.185
103.186
103.187
103.188
103.189
105.002
105.001
104.007
104.005
125.037
125.033
125.034
125.035
125.036
125.032
113.033
113.034
113.035
104.027
129.001
125.029
125.030
125.031
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
5
5
5
1
1
5
5
5
Narrow Neoguide Surgical Kit Case
Narrow Neoguide Pilot Drill
Narrow Neoguide Rotatory Punch
Narrow Neoguide Manual Punch
Narrow Neoguide Drill Guide 2.0
Narrow Neoguide Drill Guide 2.8
Narrow Neoguide CM Mount
110.225
103.196
103.194
103.195
125.039
125.040
113.037
1
1
1
1
1
1
2
ItemsincludedinNarrowNeoguideKit
*illustrative photos
122
NeoguideDrills
• Twist Drill for Ø1.3 and Ø2.0 and Tri-Spade for another diameters;• Available in surgical stainless steel;• Sequence for perforation of surgical alveolus;• Drill 1.3 for perforation in the fixing tubes of Surgical Guide;• Markings from 7 to 17mm.
103.179 103.183 103.184 103.185 103.186
ø1.3 ø2.0 ø2.8 ø3.0 ø3.3
103.187 103.188 103.189
NeoguidePilotDrills
• Surgical stainless steel coated in carbon, which provides a lower friction coefficient;
• Preparation of the bone crest for seating of cervical third in CM Titamax Implants;
• Indicated for bones type I and II.
ø3.5 ø3.75 ø4.0
NeoguideInitialDrill
103.182
• Surgical Stainless Steel with a carbon coating that provides reduced frictions;
• Breaking of cortical bone.
Punch
• Surgical stainless steel coated in carbon, which provides a lower friction coefficient;
• Guided circular incision for mucosa removing;• Rotatory Punch – used with contra-angle;• Manual Punch – used manually with Digital Drivers for Torque Connections (104.028);
• Also indicated as circular scalpel.
103.180
103.194
103.181
103.195
Rotatory Manual
NeoguideMount
• Surgical stainless steel;• Specific mount for Neoguide technique;• Narrow Neoguide Kit Mount is used only to the installa-tion of CM Implants Ø3.5mm.
113.033 113.034 113.035
ø3.5 ø3.75 ø4.0
125.037
DriverforNeoguideMount
• Assists in exchange of conventional Mount for the specific Mount of the Neoguide Technique.
Neoguide Kit
Neoguide Kit
Neoguide Kit
Narrow Neoguide Kit
Narrow Neoguide Kit
Narrow Neoguide Kit
113.037
103.196
DRILLPLUS:Count with the application of a thin pellicle with carbon basis, which promotes low friction coefficient and reduction of the heat generated on osteotomy.
123
125.029
125.032
125.030 125.031
ø3.5 ø3.75 ø4.0
GuideforNeoguideImplants
• Available in Titanium;• Guide for installation of CM Implants in Neoguide Technique;
• The colors indicate the CM Implant diameter.GuideClamp
• Titanium;• Pin for fix the surgical guide over the ridge;• Effective length of 12mm and Ø 1.3mm.
DrillGuide
• Use the corresponding drill to the Surgical Guide diameter (colors);• Embedded in the washers of Surgical Guide;• The colors indicate the CM Implant diameter.
125.033Neoguide Kit
125.039Narrow Neoguide Kit
125.034
125.040
125.035 125.036
ø2.0 ø2.8 ø3.0 ø3.3 • Available in Titanium;• Used with Mini Conical Abutment Analogue for obtain the work model;
• 3 spreaders with 1mm of height included;• Technique for prosthesis construction before the surgery.
Neoguide
Support
101.054
124
Su
rgic
al
Te
ch
niq
ue
s
Demonstrativesequenceof
PassiveFitting
Technique that allows the passive fitting without
welding through Titanium cylinder cementation in
the metallic structure. Used for multiple prosthesis
and results in laboratorial working time reduction.
125
PassiveFitting
Dem
onstrativesequenceof
118.083
118.250
118.086
118.174
118.089
118.081
118.248
118.084
118.173
118.087
118.082
118.249
118.085
118.172
118.088
Castable
Castable
Castable
Castable
ø4.1
ø5.0
Brass
Brass
Brass
Brass
Titanium
Titanium
Titanium
Titanium
PassiveFittingCylindersofMiniConicalAbutment
PassiveFittingCylindersofMicroConicalAbutment
PassiveFittingCylindersofTransepithelialAbutment
GTPassiveFittingCylinders
PassiveFittingWorkingScrew
4.1 mm 5.0 mm
116.086 116.087
126
1 Regularization of the alveolar ridge. 2 Surgical perforation concluded, checking the correct distance of the Distal Implant in relation to the mentual foramen with a 7mm flag.
3 Installation of 5 CM "C" Titamax Implants Ø3.75.
4 Installation of CM Mini Abutments. 5 Installation of squared transfers, replacing by the short screws (mini abutment cylinder screw) and making the union of transferents with acrylic resin.
6 Positioning of the Multifunctional Guide to obtain the intermaxillary relations. Make the union with acrylic resin of the transferents. After union, inject fluid silicon to the soft tissue impression.
7Removal of Multifunctional Guide and installation of Mini Abutment Analogues to the transferents.
8 Work model with artificial gingiva. 9 Castable Passive Fitting Cylinder, Brass Passive Fitting Cylinder and Titanium Passive Fitting Cylinder with slots and lower diameter than brass, compensating the casting contraction.
PassiveFittingDemonstrativesequenceof
127
1 0 Brass Cylinders are placed over the analogues and receive Castable Cylinders fixed with work screws.
1 1 1 2Casting ring with waxed infrastructure.
1 3
Casted infrastructure.
1 4Infrastructure adaptation over the model.
Final intraoral view.
PassiveFittingDemonstrativesequenceof
1 5Observe area for cementation.
1 6
Cementation with Panavia® (Kuraray Med. Inc. Tokyo-Japan) of the structure over the Titanium cylinders;
1 7Cementation with Panavia® (Kuraray Med. Inc. Tokyo-Japan) of the structure over the Titanium cylinders;
128
Su
rgic
al
Te
ch
niq
ue
s
Demonstrativesequenceof
DistalBar
ø4.1
ø5.0
PolishingProtector
123.008
Mini Abutment GT
123.009
123.012
• Protector for cylinders during finishing and polishing of prosthesis;
• Use the corresponding screw to the component for fixation.
• Technique for facilitate mandibular rehabilitations with
Passive Fitting using a prosthesis type implant-supported
provisional protocol.
ø4.1
ø5.0
DistalBarCylinder
118.169
Mini Abutment GT
118.160
118.171
• Available in Titanium;• Retentions to facilitate the acrylic resin union;• Indicated torque: 10 N.cm;• Use Torque Connection 1.2 (105.005);• To torque, use Torque Connection 1.2 (105.005).
ø4.1
ø5.0
DistalBar
125.011
Mini Abutment
• Use in Distal Implants to strengthen the Cantilever.
GT
125.012
125.023
129
1
2GT Implant installed. 3Wear prosthesis, maintaining the integrity of posterior area.
4
Cylinders installation in Central Implants and of Distal Bar in posterior implants.
5Proof of the inferior prosthesis with wear (centrical occlusion position, without interference in cylinders).
6 Placement of a rubber dam over the cylinders to the soft tissue protection.
7
Application of autopolymerizable acrylic resin in the cylinders.
8 9Acrylic resin application between the cylinders
1 0
Application of inferior prosthesis in wear area, repositioning in mouth, patient in occlusion even your full polimerization.
Implant-supported provisional prosthesis concluded.
1 1
Remotion of inferior prosthesis after resin polimerization, cylinders captured.
Final intraoral posterior view.1 2Wear, finishing and polishing of inferior prosthesis with polishing protectors.
DistalBarDemonstrativesequenceof
130
119.007
119.008
119.009
ClipBarcasted.
Castable Cover for Clip
(needs casting)
Bar
(needs casting)
Clip
Su
rgic
al
Te
ch
niq
ue
s
Demonstrativesequenceof
BarClip
131
1 Construction of new total prosthesis.
Lateral view of set.
2 Implants installed. 3 Components.
4 Attachment Ball installed. 5 Using of positioners to correct the parallelism between the Implants and determinate the correct distance between O’ring and Attachment.
6 Placement of protection disks.
Placement of O’rings.7 8 9Inferior view of alleviation.
10 First O’ring captured. 11
Proof of prosthesis to verify adaption without interference.
Second O’ring captured. 12
AttachmentBallMiniDemonstrativesequenceof
132
B o n e G r a f t i n g
&
O r t h o d o n t i c A n c h o r a g e
133
Bo
ne
Gr
aft
ing
an
dO
rth
od
on
tic
A
nc
ho
ra
ge
134
*illustrative photo
111111111111111
Bone Grafting and Orthodontic Anchorage CaseBone Grafting Manual DriverPhilips Connection for Manual DriverPhilips Connection for Contra-angleDrill 1.6 for Contra-angleDrill 1.3 for Contra-angleDrill 1.1 for Contra-angleDrill 1.6 for Straight Piece Drill 1.3 for Straight Piece Drill 1.1 for Straight PieceGraver for Bone Grafting and Orthodontic Anchorage Orthodontic Anchorage DriverContra-angle connection – Anchorage - LongContra-angle connection – Anchorage – ShortRatchet Adaptor for contra-angle connections
110.227104.018105.063105.023103.045103.079103.044103.043103.078103.042103.207104.033105.039105.040105.025
CompleteKit:BoneGrafting&OrthodonticAnchorage
BO
NE
GR
AF
TIN
G
AN
D
OR
TH
OD
ON
TIC
AN
CH
OR
AG
E K
IT
135
1
1
1
1
1
1
1
1
1
1
1
Bone Grafting and Orthodontic Anchorage Case
Bone Grafting Manual Driver
Philips Connection for Manual Driver
Philips Connection for Contra-angle
Drill 1.6 for Contra-angle
Drill 1.3 for Contra-angle
Drill 1.1 for Contra-angle
Drill 1.6 for Straight Piece
Drill 1.3 for Straight Piece
Drill 1.1 for Straight Piece
Graver for Bone Grafting and Orthodontic
Anchorage
110.227
104.018
105.063
105.023
103.045
103.079
103.044
103.043
103.078
103.042
103.207
BoneGraftingKit
1
1
1
1
1
1
1
1
1
Bone Grafting and Orthodontic Anchorage Case
Drill 1.3 for Contra-angle
Drill 1.1 for Contra-angle
Drill 1.3 for Straight Piece
Drill 1.1 for Straight Piece
Orthodontic Implant Driver
Long Connection
Short Connection
Ratchet Adaptor
110.227
103.079
103.044
103.078
103.042
104.033
105.039
105.040
105.025
OrthodonticAnchorageKit
136
Expanded Head
Expanded Head
Standard Head
6mm
Ø1.5mm
Ø2.0mm
Ø2.0mm Ø3.0mm Ø3.85mm
Ø1.5mm
Ø1.5mm Ø2.5mm Ø3.70mm
Ø2.0mm
8mm
8mm
10mm
10mm
12mm
12mm
14mm
14mm
116.194
ScrewforBoneGrafting
• Available in Titanium;• Osseous block fixation; • Self-tapping.
116.196 116.198 116.199 116.200
116.203 116.205 116.207
116.210 116.211 116.212
116.214 116.215 116.216
116.213
116.209
7mmCollar
Ø1.3mm
Ø1.6mm
Ø1.3mm
Ø1.6mm
9mm 11mm
Low
Low
Medium
Medium
• Implants for orthodontic movement;• Available in Titanium alloy according to ASTM-F136 (level V);• Torque resistance up to 10 N.cm (Ø 1.3mm) and 20 N.cm (Ø 1.6mm);• Self-tapping;• Collar height: -Low Collar: 0mm. -High Collar: 1mm.
109.484 109.485 109.486
Hex Size: 2.7 mm
Hole Diameter: 0,7mm
109.487 109.488 109.489
109.493 109.494 109.495
109.496 109.497 109.498
ImplantsforOrthodonticAnchorage
1 m
m
BO
NE
GR
AF
TIN
GA
ND
OR
TH
OD
ON
TIC
AN
CH
OR
AG
E
137
• Stainless steel;• Manual installation of Orthodontic Anchorage implants.
OrthodonticImplantDriver
104.033
GraverforBoneGraftingandOrthodonticAnchorage
103.207
• Stainless steel;• Initial severance of cortical.
ConnectionsandAdaptorsOrthodonticAnchorage
• Connections for Anchorage Implant installation with Ratchet and Contra-angle.
105.040
Short
105.039
Long
105.025
DrillsforOrthodonticAnchorage
• Suitable for bones type I and II;• Markings referent to the implant length (7.9 and 11mm).
103.042
7 mm9 mm
11 mm
103.078 103.043
103.044
Ø 1.1mm Ø 1.3mm Ø 1.6mm
Straight Piece
Contra-angle 103.079 103.045
BO
NE
GR
AF
TIN
G
AN
D
OR
TH
OD
ON
TIC
AN
CH
OR
AG
E
138
PhilipsDriver
HandDriver
104.018
105.063
Straight part
105.023
Contra-Angle
• Assists in handling of Philips Driver (105.063) and of Graver for Bone Grafting and Orthodontic Anchorage (103.207).
• Stainless steel;• Screws installation for Bone Grafting.
BO
NE
GR
AF
TIN
G
AN
D
OR
TH
OD
ON
TIC
AN
CH
OR
AG
E
139
Package of Orthodontic Anchorage Implant. Seal opening to get the implant in sterile capsule.
Cover removal to access the implant. Capture of implant with Orthodontic Anchorage Contra-angle Connection(105.040).
Option to insert the implant with a micromotor. Implant installation.
Insert option of implant manually with Orthodontic Anchorage Driver (104.033).
Implant installed.
1
3
5
7
2
4
6
8
Sequenceof
BO
NE
GR
AF
TIN
GA
ND
O
RT
HO
DO
NT
IC A
NC
HO
RA
GE
140
I n s t r u m e n t s
141
STERILISE
Sterilize on the eve of or in the day of procedure. It is
recommended, preferably, follow the method of sterilization
by steam autoclaving, and also the parameters and procedures
established in the regulation BS EN ISO 17665-1:2006 Moist
heat. Requirements for the development, validation and routine
control of a sterilization process for medical devices, or to proceed
conforming to the instructions manual from the manufacturer of
the autoclave.
WARNING: THE KITS ARE DAMAGED WHEN SEALED WITH
ADHESIVE TAPE.
DO NOT STERILIZE PRODUCTS MADE IN POLYMER AT HOTHOUSE.
VALIDITY OF STERILIZATION: 7 to 15 days, since kept in clean
environment, dry and away from the sun.
HYGIENE
Kits Neodent and surgical instruments should be properly
cleaned after each use. Do not let them in contact with
moisture for prolonged periods.
1stStep:Disassemblepiece(ifapplicable).
2ndstep:Immergethewholepieceinenzymaticdetergent
withsolutionof10%.
3rdStep:Washinanultrasonicwasherforabout10minutes,
4thstep:Rinsewithdistilledwaterinabundancetoremove
completelythesolutionresidues,makinguseofbrushes.
5thstep:Drywithcleananddryclothorcompressedair.
6thstep:Realizevisualinspection,observingifthecleaning
processhasbeensuccessful.Ifthereisanydirt,thepiece
shouldbere-immersedindetergent–1stand2ndsteps-,
and,ifisnecessary,thecleaningshouldbedonewiththe
helpofawirebrushfordentaluse(repeattherinsingand
dryingsequence).
7thStep:Selectthepackaginginaccordancewiththe
sterilizationprocess.Preferablyusesurgicallevelfilmand
paperenvelope.
IMPORTANT: Never store the material without complete drying.
Drying is very important to prevent oxidations.
ATTENTION: Do not use not incrusted products (non-enzymatic).
They tend to darken the pieces and also cause oxidation. The
use of enzymatic liquid with concentration higher than 10%, as
well as drying of pieces containing cleaning solution residues,
helps oxidation and must be avoided. Ins
tr
um
en
ts
142
Su
rgic
al
Kit
ProductCharacteristics:
• Case in autoclavable polymer;
• Drivers, connections and surgical instruments for
Titamax Implants and External Hex Alvim, Internal Hex,
Morse Taper and GT.
Observation:ItemscontainedinSurgicalKitarealsosoldseparately.Following,threesurgicalkitsaresuggested:Initial,IntermediaryandAdvanced.
143
ItemscontainedinSurgicalKit Advanced
Interm
ediate
Initial
110.206
103.170
103.171
103.162
103.213
103.163
103.164
103.165
103.166
103.167
103.168
103.172
103.173
103.174
103.209
103.239
103.211
103.242
103.216
103.217
103.218
103.219
103.220
103.091
105.047
105.045
105.046
105.050
105.048
105.049
105.001
105.018
105.002
128.015
113.014
113.020
113.036
128.019
128.020
128.021
128.022
128.023
104.039
104.007
104.028
104.027
129.004
129.001
105.030
105.031
105.068
103.077
103.070
Surgical Kit Case
Initial Drill PLUS
Alvim Twist Drill 2.0 PLUS
Twist Drill 2.0 PLUS
Pilot Drill 2/3 PLUS
Twist Drill 2.8 PLUS
Twist Drill 3.0 PLUS
Twist Drill 3.15 PLUS
Twist Drill 3.3 PLUS
Twist Drill 3.8 PLUS
Twist Drill 4.3 PLUS
Alvim Drill 3.5 PLUS
Alvim Drill 4.3 PLUS
Alvim Drill 5.0 PLUS
Countersink Drill 3.3 PLUS
SF Countersink Drill 4.1 PLUS
Countersink Drill 4.3 PLUS
SF Countersink Drill 4.5 and 5.0 PLUS
CM Pilot Drill 2.8/3.5 PLUS
CM Pilot Drill 3/3.75 PLUS
CM Pilot Drill 3.3/4.0 PLUS
CM Pilot Drill 3.6/4.3 PLUS
CM Pilot Drill 4.3/5.0 PLUS
Extension Drill
Connection for TI Contra-angle 4.1 and 4.3
Short TI Ratchet Connection 4.1 and 4.3
Long TI Ratchet Connection 4.1 and 4.3
Contra-angle TI Connection 5.0
Short TI Ratchet Connection 5.0
Long TI Ratchet Connection 5.0
Hex Connection for Short Ratchet
Hex Connection for Long Ratchet
Hex Connection for Contra-angle
Height Measurer CM
H.E. Long Mount 3.3
GT Mount
CM Long Mount 3.5
Parallel Indicators 2.8/3.5
Parallel Indicators 3.0/3.75
Parallel Indicators 3.3/4.0
Parallel Indicators 3.6/4.3
Parallel Indicators 4.3/5.0
Short Digital Driver 0.9
Short Digital Driver 1.2
Digital Driver for Contra-angle Connections
Surgical Torque Ratchet Driver
Depth Probe
Titanium Tweezers
Short Ratchet Connection II Plus
Long Ratchet Connection II Plus
Contra-angle Connection II Plus
Countersink Drill II Plus 4.3
Countersink Drill II Plus 5.0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
*illustrative picture
144
WS
Kit
ProductCharacteristics:
• Case in autoclavable polymer;
• Drivers, connections and surgical instruments for CM
Titamax Implants and WS Titamax installation.
Observation:ItemscontainedinSurgicalKitarealsosoldseparately.Descriptionsshownnext.
145
ItemscontainedinWSKit
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
WS Surgical Kit Case
Initial Drill Plus
Twist Drill 2.0 PLUS
Twist Drill 2.8 PLUS
Twist Drill 3.0 PLUS
Twist Drill 3.3 PLUS
Twist Drill 3.8 PLUS
Twist Drill 4.3 PLUS
Twist Drill 5.3 PLUS
Extension Drill
Pilot Drill 2/3 PLUS
CM Pilot Drill 3.0/3.75 PLUS
CM Pilot Drill 3.3/4.0 PLUS
Pilot Drill 3.8/4.3 PLUS
CM Pilot Drill 4.3/5.0 PLUS
Pilot Drill 4.3/5.3 PLUS
CM Pilot Drill 5.3/6.0 PLUS
Short Digital Driver 1.2
Surgical Torque Ratchet
Hex Connection for Short Ratchet
Hex Connection for Long Ratchet
Hex Connection for Contra-angle
WS Post 4.5x6x0.8 Prosthetic Selection
WS Post 4.5x6x1.5 Prosthetic Selection
WS Post 4.5x6x2.5 Prosthetic Selection
WS Post 4.5x6x3.5 Prosthetic Selection
Parallel Indicators 3.0/3.75
Parallel Indicators 3.3/4.0
WS Parallel Indicators 4.3/5.0
WS Parallel Indicators 5.3/6.0
Titanium Tweezers
Depth Probe
110.218
103.170
103.162
103.163
103.164
103.166
103.167
103.168
103.169
103.091
103.213
103.217
103.218
103.214
103.220
103.215
103.221
104.007
104.027
105.001
105.018
105.002
114.230
114.231
114.232
114.233
128.020
128.021
128.024
128.025
129.001
129.004
*illustrative picture
146
Dri
lls
ProductCharacteristics:
The drills suffer wear during their use. Evaluate
their cut effectiveness periodically and observe the
need for substitution to avoid loss of implants.
DRILLSPLUS:Counts upon the application of a
thin pellicle with carbon basis which promotes
reduced friction and reduction of the heat gener-
ated in the osteotomy.
147
InitialDrillPlus
103.170Ø 2.0
• Surgical Stainless Steel;• Cortical disruption;• Diameter of 2.0mm.
AlvimDrill
Plus(Scaled)
• Surgical Stainless Steel and Zirconia;• Instrumentation sequence of surgical alveolus for Alvim Implants;
• Lenghts: -Standard: 35 mm.
103.174 103.255
103.173 103.254
103.172 103.253
Surgical Stainless Steel
Surgical Stainless Steel
Surgical Stainless Steel
Surgical Stainless Steel
Surgical Stainless Steel
Zirconia
Zirconia Zirconia
Zirconia
Zirconia
8.010.0
11.513.0
16.0
Ø 3.5
Ø 4.3
Ø 5.0
• Surgical Stainless Steel and Zirconia;• Its function is increase the surgical alveolus diameter, facilitating the next drill entry;
• Substitutes the Countersink Drill in use of the Morse Taper Implants;
• Markings indicates: osseous level, 1.0mm and 2.0mm intraosseous.
PilotDrillPlus
103.216 103.272
103.218 103.274
103.219 103.275
103.220 103.276
103.213
103.217 103.273
103.214 103.270
103.215 103.271
2.8/3.5 mm
3.3/4 mm
3.6/4.3 mm
4.3/5 mm
2/3 mm
3/3.75 mm
3.8/4.3 mm
4.3/5.3 mm
103.221 103.2775.3/6 mm
5.07.0
11.0
1.0
17.015.0
2.0Nível ósseo
6.0
9.0
13.0
CountersinkDrillPlus
• Surgical Stainless Steel and Zirconia;• Prepare of the bone crest for cervical third seating in Implants 3.3, 3.75, 4.0,4.5 and 5.0mm (external hex) and 4.3 and 5.0mm (internal hex).
103.212 103.268
103.242 103.292
103.209 103.263
ExternalHex InternalHex
Ø 4.1SlimFit
Ø 3.3
103.210 103.267Ø 5.0
103.211 103.293Ø 4.3
Ø 4.3
Ø 4.5/ Ø 5.0
Ø 5.0
103.077 103.298
103.070 103.299
TwistDrillPlus
103.171 103.232103.222103.228Ø 2.0
Short Alvim Short Alvim Long
103.162
Intermediate
• Surgical Stainless Steel and Zirconia;• Instrumentation sequence of surgical alveolus for Titamax Implants;• Lenghts: -Short: 31mm; -Intermediate: 35mm; -Long: 43mm.
103.224
103.225
103.230
103.231
Ø 3.0
Ø 3.15
Ø 3.3
103.164 103.245
103.166 103.247
103.165 103.246
103.226
103.227
Ø 3.8
Ø 4.3
Ø 5.3
103.167 103.248
103.168 103.249
103.169 103.250
103.223103.229Ø 2.8 103.163 103.244
148
Contra-angleConnection
• To capture the implant directly on the package;• For installation of External Hex Ti Implants and Internal Hex Ti Implants with contra-angle, or coupled to the Digital Driver (104.028) for manual installation;
• With tweezers to increase the security in transport and implant installation.
105.047 105.050 105.068
RatchetConnection
105.049 105.030 105.031105.048105.046105.045
4.1/4.3 5.0
5.0 4.3/5.0 4.3/5.05.04.1/4.34.1/4.3
4.3/5.0
ExternalHex–Ti InternalHex–IIPlus
Short Short Short Long Long Long
• For the installation of External Hex TI Implants and Internal Hex II Plus with Surgical Torque Ratchet Driver (104.027);
• Ratchet Connection II Plus with markings indicating the face position of internal hex.
• Available in Titanium;• Instrumental for implant position orientation;• Diameter of the central belt corresponding to the CM Implants diameter;
• Smaller side for use after drill 2.0mm;• Bigger side for use after last drill, before the implant installation.
ParallelIndicators
ExternalHex–TI InternalHex–IIPlus
128.019
128.020
128.021
128.022
128.023
128.024
128.025
WS
2.8/3.5
3.0/3.75
3.3/4.0
3.6/4.3
4.3/5.0
Ø 4.3/5.0
Ø 5.3/6.0
149
HexConnectionforContra-Angle
• Available in surgical stainless steel;• Adaptation of hex mounters;• For implant insertion, using motor and contra-angle;• Silicone ring for best fixing and mounter transport.
105.002
HexConnectionforRatchet(RatchetDriverConnection)
• Available in surgical stainless steel;• Adaptation of hex mounters;• Fit in squared ratchets;• Silicone ring for best fixing and mounter transport.
105.018105.001
Mounters(ImplantMount)
• Available in Titanium;• Requires Hex Connections 105.002 in motor use and 105.001 for Ratchet;
• Use Hex Driver 1.2mm for handling (104.007);• Long mounters 3.3 and 3.5 indicated for substitute the implant mount in cases of reduced interproximal space (mesio-distal).
113.014 113.020
GT
113.036
CM ExternalHex.
ø3.3mmø3.5mm
DrillExtension
• Available in surgical stainless steel;• With clamp bolt for drill fixation;• Fix screw to the drill extension;• For tighten and unleash the screw, it is necessary only around half turn of Hex Driver 1.2 (104.007).
103.091
150
DigitalDriver
• Available in surgical stainless steel;• Connected to the Contra-angle Connections Ti and II Plus, it becomes a manual driver for the implant installation.
104.028
HexDigitalDriver0.9mm
• Available in surgical stainless steel;• With divergent hex for best fixing and screw transport;
• Handling of Cover Screws in Implants 3.3, 3.5, 3.75,4.0, 4.3 and Healing 3.3 height 2mm.
-Short: 20mm; -Intermediate: 25mm; -Long: 38mm.
104.040104.041104.039
Medium LongShort
HexDigitalDriver1.2mm
• Available in surgical stainless steel;• With divergent hex for best fixing and screw transport;
• Handling of Mounters in Implants and Cover Screws.
-Short: 20mm; -Intermediate: 25mm; -Long: 38mm.
104.010104.012104.007
Medium LongShort
151
TitaniumTweezers
• To implants manipulation;• New system of tweezers, that avoids the deviation of the active tip;
• Scale in milimeters, for conference during the procedures.
129.001
SurgicalTorqueRatchetDriver
• Available in surgical stainless steel;• Extremely secure (a variation of less than 5%);• Realize calibration annually;• Fitting for square connections;• Collapsible ratchet, that allows the correct cleaning of set.
104.027
UseInstructions
The Surgical Torque Ratchet Driver was projected to allow the required torque application, and also allow that this torque be checked simultaneously with the same instrument.
The Neodent Surgical Torque Ratchet has pre-calibrated torques.
The ratchet function serves for both sides. Just pull and turn the pin driver 180°. However, the torque function is only in clockwise.
For this, only apply the force on the RATCHETSTEM, 1 until it reaches the value set in LATERALGRADUATION2which corresponds to the desired torque.
•Prosthetic: 10,15,20,32 and 45 N.cm;•Surgical: 45,60 and 80 N.cm.
CAUTION: When you reverse the direction of torque, the gear can be detached from the driver body and fall it. Therefore, this reversal should only be done with the driver connected to the piece or outside the patient’s mouth.
152
Pro
sth
etI
c I
ns
tru
me
nts
110.213105.065105.041105.005105.006105.007105.008105.009105.044105.071128.015104.005104.016104.026
Prosthetic Kit CaseTorque Connection 0.9Short Torque Connection 1.2Torque Connection 1.2Torque Connection 1.6Slot Torque ConnectionSquare Torque ConnectionConical Torque Connection 4.1Short Conical Torque Connection 4.1Long Torque Connection 1.2CM Height MeterDigital Driver for Torque ConnectionsTransfer DriverProsthetic Torque Ratchet Driver
XXXXX X X X X X X X X X
XXXXX
X X
X
11111111111111
*illustrative picture
Complete
Basic
153
• Surgical stainless steel;• Cleansing and sterilizing of the disassembled ratchet;
• Extremely secure (variation less than 5%);• Realize calibration annually;• Fitting for square connections;
ProstheticTorqueRatchetDriver
104.026
UseInstructions
The Surgical Torque Ratchet Driver was projected to allow the required torque application, and also allow that this torque be checked simultaneously with the same instrument.
The Neodent Surgical Torque Ratchet has pre-calibrated torques.
The ratchet function serves for both sides. Just pull and turn the pin driver 180°. However, the torque function is only in clockwise.
For this, only apply the force on the RATCHETSTEM,1until it reaches the value set in LATERALGRADUATION,2 which corre-sponds to the desired torque.
•Prosthetic: 10,15,20,32 and 45 N.cm;• Surgical: 45,60 and 80 N.cm.
CAUTION: When you reverse the direction of torque, the gear can be detached from the driver body and fall it. Therefore, this reversal should only be done with the driver connected to the piece or outside the patient’s mouth.
ProstheticAdaptationDriver
•Mandrel for analogues fixing and prosthetic components machining..
104.036
154
DriversandTorqueConnections
•Surgical Stainless Steel;•Observe corresponding connection to the prosthetic component screw;
•To torque control, the connections must be adapted to the Prosthetic Torque Ratchet Driver (104.026);
•To connections manual torque, must be adapted to the Digital Driver (104.007);
105.009
Square Slot 1.61.20.9
105.065 105.005 105.006 105.007 105.008 104.005105.041 105.042 105.044
1.6Short
1.2Short
Conical 4.1
Conical4.1 Short
Digital
105.071
1.2Long
• Surgical Stainless Steel;• Indicated for Conical Transfer (used in closed tray transfer).
TransferDriver
104.016
• Surgical Stainless Steel;• Length: -Short: 2 cm; -Intermediate: 2.6 cm; -Long: 3.8 cm; • Observe screw indications.
DigitalDriver0.9mm DigitalDriver1.2mm
104.039 104.007
Short ShortIntermediate MediumLong Long
104.041 104.012104.040 104.010
• Surgical Stainless Steel;• Length: -Short: 2cm; -Intermediate: 2,6 cm; -Long: 3,8 cm.• Observe screw indications.
• Connections for torque in prosthesis screws with motor;
• Observe connection according to the cor-responding screw.
0.9
105.066
Contra-angleTorqueConnections
105.010 105.012 105.013
1.2 1.6 Slot
155
Pro
sth
eti
c I
ns
tru
me
nts
• Illustrative Photo
110.223
114.191
114.192114.193114.194114.195114.196114.197114.198114.199114.200114.201114.202114.203114.204114.205114.206114.207114.208114.209114.226114.227114.228
114.210114.211114.212114.213114.214114.215114.216114.217114.218114.219114.220114.221114.222114.223114.224114.230114.231114.232114.233104.007114.335114.336114.337
CM Prosthetic Selection Kit CaseCM Post 3.3x4x0.8 Prosthetic Selection CM Post 3.3x4x1.5 Prosthetic Selection CM Post 3.3x4x2.5 Prosthetic Selection CM Post 3.3x4x3.5 Prosthetic Selection CM Post 3.3x4x4.5 Prosthetic Selection CM Post 3.3x4x5.5 Prosthetic Selection CM Post 3.3x4x6.5 Prosthetic Selection CM Post 3.3x6x0.8 Prosthetic SelectionCM Post 3.3x6x1.5 Prosthetic SelectionCM Post 3.3x6x2.5 Prosthetic SelectionCM Post 3.3x6x3.5 Prosthetic SelectionCM Post 3.3x6x4.5 Prosthetic Selection CM Post 3.3x6x5.5 Prosthetic Selection CM Post 3.3x6x6.5 Prosthetic Selection CM Post 4.5x6x0.8 Prosthetic SelectionCM Post 4.5x6x1.5 Prosthetic SelectionCM Post 4.5x6x2.5 Prosthetic SelectionCM Post 4.5x6x3.5 Prosthetic SelectionCM Post 4.5x6x4.5 Prosthetic SelectionCM Anatomical Post Height 1.5 Prosthetic Sel.CM Anatomical Post Height 2.5 Prosthetic Sel.CM Anatomical Post Height 3.5 Prosthetic Sel.
CM Post 4.5x4x5.5 Prosthetic SelectionCM Post 4.5x4x6.5 Prosthetic SelectionCM Post 4.5x6x0.8 Prosthetic SelectionCM Post 4.5x6x1.5 Prosthetic SelectionCM Post 4.5x6x2.5 Prosthetic SelectionCM Post 4.5x6x3.5 Prosthetic SelectionCM Post 4.5x6x4.5 Prosthetic SelectionCM Post 4.5x6x5.5 Prosthetic SelectionCM Post 4.5x6x6.5 Prosthetic SelectionCM Angled Post 3.3x6x1.5 17º Prosthetic SelectionCM Angled Post 3.3x6x2.5 17º Prosthetic SelectionCM Angled Post 3.3x6x3.5 17º Prosthetic SelectionCM Angled Post 3.3x6x1.5 30º Prosthetic SelectionCM Angled Post 3.3x6x2.5 30º Prosthetic SelectionCM Angled Post 3.3x6x3.5 30º Prosthetic SelectionWS Post 4.5x6x0.8 Prosthetic SelectionWS Post 4.5x6x1.5 Prosthetic SelectionWS Post 4.5x6x2.5 Prosthetic SelectionWS Post 4.5x6x3.5 Prosthetic Selection Short Digital Driver 1.2CM Anatomical Post Lateral 1.5 Prosthetic SelectionCM Anatomical Post Lateral 2.5 Prosthetic SelectionCM Anatomical Post Lateral 3.5 Prosthetic Selection
156
S u r g i c a l I n s t r u m e n t s
157
SU
RG
ICA
L
INS
TR
UM
EN
TS
158
TrephineBurs
103.051 103.026 103.087 103.027 103.028 103.029
Ø3.3mm Ø4.1mm Ø4.3mm Ø5.0mm Ø8.0mm Ø10.0mm
• Surgical Stainless Steel;• Osseous cylinder collect;• Implants removal;
BoneProfileDrill
Ø3.3mm Ø4.1mm
ExternalHex InternalHex
Ø4.3mm Ø5.0mm Ø4.3mm Ø5.0mm
• Surgical Stainless Steel;• Used in the second surgical phase;• Adapt the bone around implant platform, preparing the emergency profile compatible with the prosthetic component profile;
• Each drill has a guide with specific diameter.
103.039 103.030 103.085 103.031 103.102 103.103
AngleMeter
• Available in Titanium;• Angulations: 17° and 30°.• For selection and angulation planning of prosthetic component during the surgical procedure;
• Use indication: after Twist Drill 2.0.
128.017
17º
128.018
30º
Flags
128.008 128.007
9 mm 12 mm128.003
7 mm
• Surgical Stainless Steel;• Adaptive to mirrors handle;• Indicated for surgical/prosthetic planning.
ProstheticSurgicalGuide
103.093
Pin
103.092
Guide
• Available in Titanium;• Components for surgical guide construction;• Internal diameter of prosthetic guide 2mm;• Heights: 6mm and 10mm;• Surgical Guide: package with 10 units (5 units of 10mm and 5 units of 6mm);
• Surgical Guide Pin: package with 5 units.
AlvimRadiographicPositioner
129.013 129.014129.009
• Available in Titanium;• Used to check flapless osteotomy depth;• It is suggested make the periapical radiography for evaluation.
Ø 3.5 mm Ø 4.3 mm Ø 5.0 mm
0.35mm
16
11.513
10
8
159
1.8mm
1.8mm
2.5mm
2.5mm
3.0mm
3.0mm
3.5mm
3.5mm
4.0mm 4.5mm
• Surgical Stainless Steel;• Concave cutting tip for atraumatic elevation of maxillary sinus floor;
• Used in the preparing of surgical alveolus for implants installation in posterior maxillary area, which has less osseous height;
• Markings from 7 to 17mm.
• Surgical Stainless Steel;• Convex tip;• Used when thickness bone is insufficient, requiring compression and prior bone expansion to the implant placement;
• Markings from 7 to 17mm.
110.154
110.160
110.155
110.161
110.156
110.162
110.157
110.163
110.158 110.159
Osteotomes
OsteotomesModified
OsteotomesTray
• Autoclavable polymer;• Osteotomes sold separately.
110.180
17 mm13 mm9 mm
15 mm11 mm7 mm
17 mm13 mm9 mm
15 mm11 mm7 mm
160
Mallet
CurettesforSinusLifting
• Surgical Stainless Steel;• Detachment of sinusal membrana.
126.008 126.009 126.010 126.011 126.012
•Surgical Stainless Steel;•Used in compactors and expanders;•Weight: 150g.
126.001
161
DisposableBoneScraper
• Used to remove autogenous bone;• Unique usage;• Sterile.
127.023
127.016
Reto
127.017
Positivo
127.018
Negativo
127.019
Lâmina
MetalBoneScraper
• Used to remove autogenous bone applied in reconstructive surgery;
• Autoclavable;• Blade included;• Silicone handle;• Blade coated with Aluminium Nitride.
DisposableBoneCollector
• Used to collect autogenous bone;• Polymer;• Unique usage;• Adaptive to vacuum pump;• Two disposable sieves included;• Use the second tip to saliva suction (beware of contamination).
107.003
107.008
162
SurgicalLabialRetractor
124.001
• Available in Surgical Stainless Steel;• Rounded corners to minimize the surgical trauma.
ColumbiaRetractor
• Available in Surgical Stainless Steel;• Rounded corners to minimize the surgical trauma.
124.003
DepthProbe
• Available in Titanium;• For probing preparation and depth analysis;
• Scale in milimeters for conferences during procedure.
129.004
ScalpelHandle
• Available in Surgical Stainless Steel;• For use of conventional scalpel blade;• Blade not included.
129.008
163
BladeandHandleBivers
• Handle and blade in surgical stainless steel;• Atraumatic exodontics to implants installation;• Similar with a periostomal;• Blades supplied individually.
ComplementTray
• Autoclavable polymer;• Used to organize the drills and auxiliar con-nections.
110.211
Test
BoneMill
• Surgical Stainless Steel;• Bone volume gain;• The blade has 3-year of warranty against rust;• With lever for better facility during utilization;• Bone mill pestle with slots to optimize the bone block locking during use;
• Avoid bone handling originated in tissue bank.
Bovine bone block with volume = 1,76 cm³
Volume gain was approximately of 7 times.
Particles amplified.
127.011
129.002
129.005
164
Su
rgic
al
Mo
tor
1
2
3
6
7
4
5
Calibration System
Contra-angle Without light With light
Electronic Electronic and Mechanical (Dynamometre)
The Neosurg XT and XT Plus are small, light and can be easily transported anywhere. The products are ideal for anyone who tends to more than one surgery and wishes to have just one surgical motor.
As well as electronic calibration, the Neosurg XT Plus has a torque ratchet to guarantee yet more precision of the micro motor and contra-angle. The calibration is executed directly by the professional, without the need for maintenance from the manufacturer.
It´s not necessary to autoclave, the hose system is sterilisation only.
Allows perfect adaption of the irrigation handle, offering resistance and security. Can be sterilised.
Use the magnetic induction system, which does not produce noises nor vibrations. High Precision of the torque and variation of speeds.
Rigid body of the micro motor to not risk breaking. Doesn´t lose brightness with time of use, unlike the LED.
Highly resistant Titanium Body (XT Plus version), Internal and external irrigation system. Head with a reduced size and ergonomically compact body. Better visibility, access and mobility within the oral cavity.
All adjustments of the irrigation system, programs and speeds can be triggered by the pedal, leaving the hands free for surgical procedure. It was developed to avoid the accidental activation of micro motor system (progressive acceleration.)
CONTROL PANEL WITH EASIER INTERFACE
PORTABLE
ControlU
nit
MicroMotorContra-angle
MECHANICAL CALIBRATION SYSTEM
PUMP CONNECTED TO THE MOTOR
IRRIGATION SYSTEM WITH METAL CONNECTORS
MICRO MOTOR REINFORCED WITH A TITANIUM COATING
OPTICAL FIBER (XT PLUS VERSION)
CONTRA- ANGLE WITH REDUCED SIZE
INTELLIGENT CONTROL PEDAL
165
XT
XT PLUS
CONTRA-ANGLE WITH DENTAL LEVER
CONTRA-ANGLEPUSH BUTTON
WITH LIGHT
130.001
132.023
132.002
132.025
2 EXCLUSIVENEOSURGXTPLUS
5
67
4
3
1
Illumination
166
BauruAl. Dr. Octávio Pinheiro Brizolla, 7-4617012-059 - Bauru - SP - BrazilPhone: ++ 55 14 3201-3500
BeloHorizonteR. Grão Pará, 55430150-341 - Belo Horizonte - MG - BrazilPhone: ++ 55 31 3071-8700
BrasíliaSH/SUL, QD. 06 CONJ “A” BL. “F” Loja 2070316-901 - Brasília - DF - BrazilPhone: ++55 61 3298-3200
CuritibaAv. Visconde de Guarapuava, 383280250-220 - Curitiba - PR - BrazilPhone: ++ 55 41 2169-1000
USA3785 NW 82 Avenue Suite 211Zip Code 33166Doral - FLPhone: 305-913-7136
GoiâniaR. T-55, 199 - Sl. 4 a 674150-320 - Goiânia - GO - BrazilPhone: ++ 55 62 3878-7700
LondrinaR. Senador Souza Naves, 151086010-160 - Londrina - PR - BrazilPhone: ++ 55 43 3306-2000
PortoAlegreR. Félix da Cunha, 836 - Cj. 20290570-000 - Porto Alegre - RS - BrazilPhone: ++ 55 51 3272-7400
PortugalAv. Defensores de Chaves, 15 - 3º D1000-109 Lisboa - PortugalPhone: ++ (351) 21 013 4400
RecifeR. Francisco Alves, 325 - Sl. 40150070-490 - Recife - PE - BrazilPhone: ++ 55 81 3202-6900
RiodeJaneiroR. 2 de Dezembro, 38 - Cj. 302 a 30522220-040 - Rio de Janeiro - RJ - BrazilPhone: ++55 21 3622-8900
SãoPauloR. Francisco Leitão, 469 - Sl. 180905414-020 - São Paulo - SP - BrazilPhone: ++ 55 11 3728-2700
VitóriaR. Cassiano Antônio Moraes, 100 - Loja 0229050-525 - Vitória - ES - BrazilPhone: ++ 55 27 3203-5300
DISTRIBUTORSINBRAZIL
CampoGrande–MSAlphadent Implantes e InstrumentaisR. Padre João Cripa, 2385 – Bairro: Vila AltaCEP: 79010-180Phone: (67) 3027-5993 / 0800 600 5993
Cuiabá–MTAlphadent Implantes e InstrumentaisPhone: (67) 3027-5993 / 0800 601 5993Av. São Sebastião, 2454 – Bairro: PopularCEP: 78045-400
Florianópolis–SCImplantológica - Revenda NeodentPhone: (48) 3225-6069 / 0800 600 6069R. Tenente Silveira, 713 – CentroCEP: 88.010-301
Manaus–AMA R. RodriguezPhone: (92) 2121-7700Av. Nabuco, 2235CEP: 69.020-0z
Salvador-BAImplante Way Produtos Médicos-Odontológicos LtdaPhone: 0800 284 5378 / Fax: (71) 3351-5378 Rua Senador Theotônio Vilela, 190 Ed. Convention Center , SL 506 - Pq Bela Vista BACEP 40279-435
ArgentinaHorácio Y Norberto CalamanteSanta Fé 31532000 RosarioPhone: 54 341 438 [email protected]
ChileComercial Express DentRut 78.378.3160-3 Av. Presidente Errazuriz 4125Las Condes – Santiago - ChilePhone: 56 2 233 6690/ 56 2 263 [email protected]
ColombiaNeoimplants Colômbia Ltda.Calle 119 N. 14 A - 25 Ofic. 107 - BogotáPhone: 752 151 560 17595 [email protected]
SpainP.D. Per, S.LCristóbal De Boleda, 1425006 - LleidaPhone: 34 9021 17077/ 9021 [email protected]
ItalyBio-sferaVia C. Pavese, 50Peschiera Borromeo – MiPhone: 39 349 224 [email protected]
LebanonImplanet Dekwaneh Slaf Main Road Yervan Bldg - BeirutPhone: 961 169 [email protected]
MoroccoSarl Innov MatSect 2, Rue Al Missouak Nr 20Hay Riad - RabatPhone: 212 37 680892 / 212 61 [email protected]
ParaguayD & D Distribuidora S.ACap. Lezcano Esq PascualToledo 2321 Ruc 80025797-9 - Asunción Phone: 595 21 310 [email protected]
DominicanRepublicDeposito Dental Idemefa S/aCalle Pedro A Bobea, Esq. Primera, Bella VistaSanto DomingoPhone: 809 535 [email protected]
TaiwanHanns Dental Suply Company 2f 50 Fuxing N Road, 10488 Taipei - Taiwan Rov Phone: 852 254 01158 [email protected]
VenezuelaDental El BosqueAv. Universitaria Resd Diamante Local P.B.Valle Abajo - Caracas Phone: 58 212-6614280 / 6617790 / [email protected]
INTERNATIONALDISTRIBUTORS
AFFILIATES