NEK606 Offshore & Marine Cables

126
NEK 606 Offshore & Marine Cables NEK606 STANDARD www.caledonian-cables.co.uk www.addison-cables.ccom Caledonian www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

description

Caledonian provides a broad range of offshore and marine specification cables which are designed primarly for power, control, instrumentation and signal cables for use in the offshore oil and gas, ship & marine industries in compliance with diffferent standards including JIS C 3410, BS6883, BS7917, NEK606, VG 95218 part 29, IEC60092, including options for flame retardant and fire resistant cables to IEC-60332 and IEC-60331. In addition we can accommodate any special requirements including specific non-standard core and sheath colours, steel wire and steel tape armour and braiding, water blocked NEK606 Offshore & Marine Cables is an example.

Transcript of NEK606 Offshore & Marine Cables

Page 1: NEK606 Offshore & Marine Cables

NEK 606 Offshore & Marine Cables

NEK606 STANDARD

www.caledonian-cables.co.ukwww.addison-cables.ccom

Caledonian

UNITED KINGDOM

Marchants Industrial Centre, Mill Lane, Laughton, Lewes, East Sussex, BN8 6AJ, UKTel: 44 (0) 207 419 5087Fax: 44 (0) 207 831 9489Email: [email protected]

HONG KONG

Unit B 22/F CMA Building, 64-66 Connaught Road Central, Hong KongTel: 852 36527508Fax: 852 35834834Email: [email protected]

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 2: NEK606 Offshore & Marine Cables

Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different cabling system products. Our superior products provide leading edge within every cable series and for every application.

Among the national and international standards with which our cables could comply are: BS - British Standard; LPCB Fire Performance Standard, ISO Standard etc. Caledonian Cables offers a comprehensive stock of cables and cabling products through its nationwide network of resellers and distributors. Caledonian Cables has continually expanded its global presence in Europe and Asia.

Caledonian & Addison, produces a wide range of cables for communication, power and electronics in its primary plants in UK, Italy and Spain. To stay in front, we continually keep expanding our manufacturing capabilities in more low cost region such as Romania, Taiwan, Malaysia etc. This low-cost manufacturing facilities enable us provide a flexible, scalable global system that delivers superior operational performance and optimal results for our customers.

Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill our customer requirements. This global presence provides design and consultancy solutions that are combined with core cable manufacturing, logistic services, and vertically integrated with our E commerce technologies, to optimize customer operations by lowering costs and reducing time to market.

Caledonian & Addison has been respected for its high standards of quality, excellent service level, competitive pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines and services. We understand the need for change and with our accurate planning, we are ready for the future and the promise of new marketing opportunities. Our tradition of growth through excellence is assured.

Our Design Centers work closely with customers to constantly improve its standard range of products and technologies and to develop customized, country and industry-specific solutions. Caledonian & Addison has established an extensive network of design, manufacturing, and logistics facilities in the world’s major markets to serve the growing outsourcing needs of both multinational and regional customers.

Page 3: NEK606 Offshore & Marine Cables

1ADDISONwww.addison-cables.com

P1 or P1/P8 RFOU/TFOU 0.6/1KV .......................................................................3P18 RU 0.6/1kV ....................................................................................................8P15 UX 0.6/1kV ..................................................................................................12

CONTENT

Medium Voltage Power Cables

Fire Resistant Power and Control Cables

Fire Resistant Medium Voltage Power Cables

Instrumentation Cables

P5 or P5/P12 BFOU 0.6/1KV ..............................................................................14P17 BU 0.6/1 kV .................................................................................................19P34 BFOU-HCF 0.6/1 kV ....................................................................................23

P2 or P2/P9 RFOU/TFOU 3.6/6KV ....................................................................26P3 or P3/P10 RFOU/TFOU 6/10KV ....................................................................29P4 or P4/P11 RFOU/TFOU 8.7/15KV .................................................................32P19 or P19/P21 RFOU 12/20KV ........................................................................35

P6 or P6/P13 BFOU 3.6/6kV ..............................................................................38P7 or P7/P14 BFOU 6/10kV ..............................................................................41P30 RFOU-HCF / TFOU-HCF 6/10(12) kV .........................................................44

S1 or S1/S5 RFOU(i) 250V .................................................................................47S2 or S2/S6 RFOU(c) 250V ................................................................................53P16 IFLI 250 V ...................................................................................................59S11 RU(i) 250 V ..................................................................................................61S12 RU(c) 250 V .................................................................................................64

Fire Resistant Instrumentation Cables

S3 or S3/S7 BFOU(i) 250V .................................................................................67S4 or S4/S8 BFOU(c) 250V ................................................................................73S13 BU(i) 250 V .................................................................................................79

Power and Control Cables

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 4: NEK606 Offshore & Marine Cables

Power and Control Cables

2 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

RG6 Armoured Coaxial Cable ..........................................................................105RG11 Armoured Coaxial Cable .........................................................................107RG59 Armoured Coaxial Cable ........................................................................109RG58 Armoured Coaxial Cable ........................................................................ 111RG213 Armoured Coaxial Cable ...................................................................... 113Mud Resistant Composite Cable ...................................................................... 115

Telecommunication Cables

Data Cables

Coaxial Cables

S9 IYXI(c) 60 V ...................................................................................................89S10 IYOI(c) 60 V .................................................................................................91

S14 BU(c) 250 V ................................................................................................82S15 BFOU-HCF(i) 250 V ...................................................................................85S16 BFOU-HCF(c) 250 V ..................................................................................87

F1 QFCI .............................................................................................................93F5 QFCB ............................................................................................................95F6 AICI ...............................................................................................................97

Cat5E UTP/FTP Armoured Data Cable ..............................................................99Cat6 UTP/FTP Armoured Data Cable ...............................................................102

Cable Code Designation ................................................................................... 117Standards and Tests ................................................................................ 118Cable Characteristics ....................................................................................... 119Electrical Data ...................................................................................................121Core Identification ............................................................................................123

Technical Information

Optical Fibre Cables

Page 5: NEK606 Offshore & Marine Cables

Power and Control Cables

3ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

P1 or P1/P8 RFOU/TFOU 0.6/1KV

Applications

These cables are flame retardant, low smoke, halogen free and mud resistant, used for control, power and lighting systems.

Standards

IEC 60092-353

IEC 60092-351

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Tinned annealed stranded copper to IEC 60228 class 2. Insulation: Halogen-free EPR. XLPE can be offered as an option (for TFOU cable)Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P1). Halogen free, mud resistant thermosetting compound, SHF MUD (for TYPE P1/P8), coloured black.

Electrical Characteristics

Nominal Cross Section Area mm² 1.5 2.5 4 6 10 16 25 35 50 70Nominal Conductor Diameter mm 1.6 2.1 2.6 3.2 4.0 5.1 6.5 7.4 8.7 10.3Maximum DC Resistant@20℃ Ω/km 12.2 7.56 4.7 3.11 1.84 1.16 0.734 0.529 0.391 0.27Continuous Current Rating@45℃ 1 Core A 23 30 40 52 72 96 127 157 196 242

Copper Wire Braid

Halogen Free EPR/XLPE Insulation

Halogen-free Bedding

Stranded Copper Conductor

SHF2/SHF MUD Sheath

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 6: NEK606 Offshore & Marine Cables

Power and Control Cables

4 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Continuous Current Rating@45℃ 2 Core A 20 26 34 44 61 82 108 133 167 206

Continuous Current Rating@45℃ 3&4 Core A 16 21 28 36 50 67 89 110 137 169

Short Circuit Current 1s A 210 360 570 860 1430 2290 3580 5010 7150 10020Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Nominal Cross Section Area mm² 95 120 150 185 240 300 400 500 630Nominal Conductor Diameter mm 12.2 13.8 15.1 17.0 19.6 21.9 24.6 27.6 32.5Maximum DC Resistant@20℃ Ω/km 0.195 0.154 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Continuous Current Rating@45℃ 1 Core A 293 339 389 444 522 601 690 780 890Continuous Current Rating@45℃ 2 Core A 249 288 331 444 444 511 587 663 757Continuous Current Rating@45℃ 3&4 Core A 205 237 272 311 365 421 483 546 623

Short Circuit Current 1s A 13590 17170 21460 26470 34340 42930 57230 71540 90140Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Note: For more than 4-cores, the current ratings may be calculated from the following formula (I I / NN 1

3= ), I1= Current rating for 1-core, N = Number of cores.

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×1.5 1.0 1.1 1.1 8.9 1351×2.5 1.0 1.1 1.1 9.3 1501×4 1.0 1.1 1.1 9.9 1801×6 1.0 1.1 1.1 10.4 2051×10 1.0 1.1 1.2 12.2 2951×16 1.0 1.1 1.2 13.5 385

Page 7: NEK606 Offshore & Marine Cables

Power and Control Cables

5ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×25 1.2 1.1 1.2 15.4 5251×35 1.2 1.1 1.3 16.9 6851×50 1.4 1.1 1.4 18.7 8701×70 1.4 1.1 1.4 20.4 11051×95 1.6 1.1 1.5 22.8 1435

1×120 1.6 1.2 1.6 24.9 17451×150 1.8 1.2 1.6 26.8 20551×185 2.0 1.2 1.7 29.3 25601×240 2.2 1.2 1.8 32.5 31901×300 2.4 1.2 1.9 35.2 39351×400 2.4 1.4 2.1 40.5 50601×500 2.4 1.4 2.2 44.0 61801×630 2.4 1.4 2.3 48.0 76202×1.5 1.0 1.1 1.2 13.6 2952×2.5 1.0 1.1 1.2 14.4 3352×4 1.0 1.1 1.3 16.1 4452×6 1.0 1.1 1.3 17.1 520

2×10 1.0 1.1 1.4 19.3 6802×16 1.0 1.1 1.5 21.7 9552×25 1.2 1.2 1.6 25.9 13352×35 1.2 1.2 1.7 27.9 15952×50 1.4 1.2 1.9 31.9 22502×70 1.4 1.2 2.1 35.8 27952×95 1.6 1.2 2.3 41.2 3780

2×120 1.6 1.4 2.4 44.8 45602×150 1.8 1.4 2.6 49.2 55002×185 2.0 1.4 2.7 53.8 66752×240 2.2 1.6 3.0 61.0 86052×300 2.4 1.6 3.2 67.0 105103×1.5 1.0 1.1 1.2 14.2 3203×2.5 1.0 1.1 1.3 15.6 4153×4 1.0 1.1 1.3 16.8 5003×6 1.0 1.1 1.4 18.1 605

3×10 1.0 1.1 1.4 20.3 7953×16 1.0 1.1 1.5 22.8 11253×25 1.2 1.2 1.6 27.5 16203×35 1.2 1.2 1.7 29.6 19553×50 1.4 1.2 1.9 33.9 27303×70 1.4 1.4 2.0 38.4 36553×95 1.6 1.4 2.2 43.8 4885

Nominal Sheath Thickness

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 8: NEK606 Offshore & Marine Cables

Power and Control Cables

6 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

3×120 1.6 1.4 2.3 47.6 60003×150 1.8 1.6 2.5 52.4 73003×185 2.0 1.6 2.7 58.6 89603×240 2.2 1.8 2.9 66.1 116103×300 2.2 1.8 3.4 71.9 134904×1.5 1.0 1.1 1.3 15.7 3504×2.5 1.0 1.1 1.3 16.6 4254×4 1.0 1.1 1.4 18.1 5904×6 1.0 1.1 1.4 19.5 725

4×10 1.0 1.1 1.5 22.1 9554×16 1.0 1.2 1.6 25.2 13754×25 1.2 1.2 1.7 30.0 19654×35 1.2 1.2 1.8 32.4 24104×50 1.4 1.4 2.0 37.3 33654×70 1.4 1.4 2.2 42.1 45804×95 1.6 1.4 2.4 48.2 6020

4×120 1.6 1.6 2.5 52.7 74404×150 1.8 1.6 2.9 58.3 88004×185 2.0 1.6 3.1 64.0 107604×240 2.2 1.8 3.4 72.4 138904×300 2.4 1.8 3.7 79.8 174055×1.5 1.0 1.1 1.3 16.7 4206×1.5 1.0 1.1 1.3 17.8 4957×1.5 1.0 1.1 1.3 17.8 5408×1.5 1.0 1.1 1.5 20.3 6459×1.5 1.0 1.1 1.5 21.5 67510×1.5 1.0 1.1 1.5 21.8 70512×1.5 1.0 1.1 1.5 22.5 80514×1.5 1.0 1.1 1.6 23.6 86016×1.5 1.0 1.1 1.7 24.9 94019×1.5 1.0 1.1 1.7 26.0 110020×1.5 1.0 1.1 1.7 27.2 113023×1.5 1.0 1.1 1.8 29.3 128524×1.5 1.0 1.1 1.8 30.0 130527×1.5 1.0 1.1 1.9 30.8 146030×1.5 1.0 1.1 1.9 31.8 152033×1.5 1.0 1.2 2.0 33.5 167037×1.5 1.0 1.2 2.0 34.6 184044×1.5 1.0 1.2 2.2 39.2 22105×2.5 1.0 1.1 1.4 18.0 555

Nominal Sheath Thickness

Page 9: NEK606 Offshore & Marine Cables

Power and Control Cables

7ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

6×2.5 1.0 1.1 1.4 19.2 5907×2.5 1.0 1.1 1.4 19.2 6558×2.5 1.0 1.1 1.5 21.8 7759×2.5 1.0 1.1 1.6 23.3 78510×2.5 1.0 1.1 1.6 23.6 86512×2.5 1.0 1.1 1.6 24.5 95514×2.5 1.0 1.1 1.7 25.5 107016×2.5 1.0 1.1 1.7 26.7 115519×2.5 1.0 1.1 1.8 28.2 136020×2.5 1.0 1.1 1.8 29.5 141023×2.5 1.0 1.1 1.9 31.8 161024×2.5 1.0 1.2 2.0 33.2 169027×2.5 1.0 1.2 2.0 33.9 181530×2.5 1.0 1.2 2.0 34.9 196033×2.5 1.0 1.2 2.1 36.7 219037×2.5 1.0 1.2 2.1 38.0 237044×2.5 1.0 1.2 2.3 42.6 2795

Note: For XLPE insulated cable, a thinner insulation thickness is applied.

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 10: NEK606 Offshore & Marine Cables

Power and Control Cables

8 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

P18 RU 0.6/1kV

Applications

These cables are flame retardant, low smoke and halogen free, used for control, power and lighting systems.

Standards

IEC 60092-353

IEC 60092-351

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Tinned annealed stranded copper to IEC 60228 class 2. Insulation: Halogen-free EPR.Outer Sheath: Halogen free thermosetting compound, SHF2, coloured black.

Electrical Characteristics

Nominal Cross Section Area mm² 1.5 2.5 4 6 10 16 25 35Nominal Conductor Diameter mm 1.6 2.1 2.6 3.2 4 5.1 6.5 7.4Maximum DC Resistant@20℃ Ω/km 12.2 7.56 4.7 3.11 1.84 1.16 0.734 0.529Continuous Current Rating@45℃ 1 Core A 23 30 40 52 72 96 127 157Continuous Current Rating@45℃ 2 Core A 20 26 34 44 61 82 108 133Continuous Current Rating@45℃ 3&4 Core A 16 21 28 36 50 67 89 110

Short Circuit Current 1s A 210 360 570 860 1430 2290 3580 5010Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Halogen Free EPR Insulation

Stranded Copper Conductor

SHF2 Sheath

Page 11: NEK606 Offshore & Marine Cables

Power and Control Cables

9ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Nominal Cross Section Area mm² 50 70 95 120 150 185 240 300Nominal Conductor Diameter mm 8.7 10.3 12.2 13.8 15.1 17.0 19.6 21.9Maximum DC Resistant@20℃ Ω/km 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607Continuous Current Rating@45℃ 1 Core A 196 242 293 339 389 444 522 601Continuous Current Rating@45℃ 2 Core A 167 206 249 288 331 444 444 511Continuous Current Rating@45℃ 3&4 Core A 137 169 205 237 272 311 365 421Short Circuit Current 1s A 7150 10020 13590 17170 21460 26470 34340 42930Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Note: For more than 4-cores, the current ratings may be calculated from the following formula (I I / NN 1

3= ), I1= Current rating for 1-core, N = Number of cores.

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1×1.5 1.0 1.0 6.0 601×2.5 1.0 1.0 6.5 801×4 1.0 1.0 7.1 1101×6 1.0 1.0 7.6 1301×10 1.0 1.1 8.5 1651×16 1.0 1.1 9.8 2351×25 1.2 1.2 11.7 3551×35 1.2 1.2 12.8 4551×50 1.4 1.3 14.4 5951×70 1.4 1.4 16.3 8051×95 1.6 1.5 18.7 10901×120 1.6 1.5 20.3 13451×150 1.8 1.6 22.4 16351×185 2.0 1.7 24.9 2075

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 12: NEK606 Offshore & Marine Cables

Power and Control Cables

10 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1×240 2.2 1.8 28.1 26601×300 2.4 1.9 30.8 33402×1.5 1.0 1.1 9.7 1452×2.5 1.0 1.1 10.5 1752×4 1.0 1.2 11.6 2252×6 1.0 1.2 12.9 2952×10 1.0 1.3 14.8 4202×16 1.0 1.4 17.2 6052×25 1.2 1.5 21.3 9402×35 1.2 1.6 23.3 11852×50 1.4 1.8 26.9 15852×70 1.4 1.9 31.9 22802×95 1.6 2.1 36.9 30902×120 1.6 2.2 40.3 37802×150 1.8 2.4 44.7 46402×185 2.0 2.6 49.5 57502×240 2.2 2.8 56.1 74602×300 2.4 3.0 62.0 92653×1.5 1.0 1.1 10.3 1653×2.5 1.0 1.2 11.1 2053×4 1.0 1.2 12.5 2803×6 1.0 1.3 13.6 3603×10 1.0 1.3 16.0 5303×16 1.0 1.4 18.5 7703×25 1.2 1.6 22.9 12003×35 1.2 1.7 25.0 15253×50 1.4 1.8 28.7 20303×70 1.4 2.0 32.6 27653×95 1.6 2.2 37.6 37453×120 1.6 2.3 41.2 46403×150 1.8 2.5 45.7 56753×185 2.0 2.7 51.2 72003×240 2.2 3.0 57.5 93003×300 2.4 3.2 66.8 120804×1.5 1.0 1.2 11.2 2004×2.5 1.0 1.2 12.4 2554×4 1.0 1.3 13.7 3404×6 1.0 1.3 15.2 4554×10 1.0 1.4 17.5 6654×16 1.0 1.5 20.4 9704×25 1.2 1.7 25.5 15304×35 1.2 1.8 27.8 19554×50 1.4 2.0 31.9 2600

Page 13: NEK606 Offshore & Marine Cables

Power and Control Cables

11ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

4×70 1.4 2.1 36.3 35404×95 1.6 2.4 42.0 48154×120 1.6 2.5 46.0 59654×150 1.8 2.7 53.5 77204×185 2.0 2.9 59.2 95704×240 2.2 3.2 67.3 124804×300 2.4 3.5 74.6 158705×1.5 1.0 1.2 13.1 2456×1.5 1.0 1.3 14.4 2757×1.5 1.0 1.3 14.4 2858×1.5 1.0 1.4 16.9 3809×1.5 1.0 1.4 18.1 39510×1.5 1.0 1.4 18.4 43512×1.5 1.0 1.4 19.0 48514×1.5 1.0 1.5 20.2 56516×1.5 1.0 1.5 21.3 61519×1.5 1.0 1.6 22.6 71520×1.5 1.0 1.6 23.8 78023×1.5 1.0 1.7 25.9 90524×1.5 1.0 1.7 26.6 92027×1.5 1.0 1.7 27.2 98530×1.5 1.0 1.8 28.4 111033×1.5 1.0 1.8 29.5 119037×1.5 1.0 1.9 30.8 131544×1.5 1.0 2.0 34.8 15605×2.5 1.0 1.3 14.3 3056×2.5 1.0 1.3 15.6 3607×2.5 1.0 1.3 15.6 3908×2.5 1.0 1.4 18.4 4959×2.5 1.0 1.5 19.9 50510×2.5 1.0 1.5 20.2 57012×2.5 1.0 1.5 20.9 62514×2.5 1.0 1.5 21.9 73516×2.5 1.0 1.6 23.3 81019×2.5 1.0 1.6 24.6 93520×2.5 1.0 1.7 26.1 103523×2.5 1.0 1.8 28.4 120524×2.5 1.0 1.8 29.2 122027×2.5 1.0 1.8 29.9 129530×2.5 1.0 1.9 31.1 147533×2.5 1.0 1.9 32.3 158537×2.5 1.0 2.0 33.8 173044×2.5 1.0 2.2 38.4 2100

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 14: NEK606 Offshore & Marine Cables

Power and Control Cables

12 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

P15 UX 0.6/1kV

Applications

These cables are flame retardant, low smoke and halogen free, used for earthing and bonding services.

Standards

IEC 60092-353

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Tinned annealed stranded copper to IEC 60228 class 2 or class 5. Insulation: Halogen free thermosetting compound, SHF2. When used as protective earth (PE) wire, the cables coloured yellow/green. When used as single wire, the cables coloured off-white, black, red or blue.

Electrical Characteristics

Nominal Cross Section Area mm² 10 16 25 35 50 70Nominal Conductor Diameter mm 4 5.1 6.5 7.4 8.7 10.3Maximum DC Resistant@20℃ Ω/km 1.84 1.16 0.734 0.529 0.391 0.27Continuous Current Rating@45℃ 1 Core A 72 96 127 157 196 242Short Circuit Current 1s A 1430 2290 3580 5010 7150 10020Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Nominal Cross Section Area mm² 95 120 150 185 240 300Nominal Conductor Diameter mm 12.2 13.8 15.1 17.0 19.6 21.9

SHF2 Insulation

Stranded Copper Conductor

Page 15: NEK606 Offshore & Marine Cables

Power and Control Cables

13ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Maximum DC Resistant@20℃ Ω/km 0.195 0.154 0.126 0.1 0.0762 0.0607Continuous Current Rating@45℃ 1 Core A 293 339 389 444 522 601Short Circuit Current 1s A 13590 17170 21460 26470 34340 42930Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed) Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thicknessmm

Nominal Overall Diametermm

Nominal Weightkg/km

1×10 2.0 8.2 160

1×16 2.1 9.4 230

1×25 2.4 11.3 350

1×35 2.4 12.4 450

1×50 2.7 14.4 600

1×70 3.0 16.7 840

1×95 3.0 18.6 1110

1×120 3.1 20.3 1360

1×150 3.4 22.4 1660

1×185 3.7 24.9 2080

1×240 4.0 28.1 2690

1×300 4.3 31.0 3330

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 16: NEK606 Offshore & Marine Cables

Fire Resistant Power and Control Cables

14 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

P5 or P5/P12 BFOU 0.6/1KV

Applications

These cables are fire resistant, flame retardant, low smoke, halogen free and mud resistant, used for control, power and lighting systems.

Standards

IEC 60092-353

IEC 60092-351

IEC 60092-359

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Tinned annealed stranded compacted copper to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR/Mica tape + XLPE.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P5). Halogen free, mud resistant thermosetting compound, SHF MUD (for TYPE P5/P12), coloured black.

Electrical Characteristics

Nominal Cross Section Area mm² 1.5 2.5 4 6 10 16 25 35 50Nominal Conductor Diameter mm 1.6 2.1 2.6 3.2 4 5.1 6.5 7.4 8.7Maximum DC Resistant@20℃ Ω/km 12.2 7.56 4.7 3.11 1.84 1.16 0.734 0.529 0.391

Copper Wire Braid

Mica Tape + HFEPR/XLPE Insulation

Halogen-free Bedding

Stranded Copper Conductor

SHF2/SHF MUD Sheath

Page 17: NEK606 Offshore & Marine Cables

Fire Resistant Power and Control Cables

15ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Continuous Current Rating@45℃ 1 Core A 23 30 40 52 72 96 127 157 196Continuous Current Rating@45℃ 2 Core A 20 26 34 44 61 82 108 133 167Continuous Current Rating@45℃ 3&4 Core A 16 21 28 36 50 67 89 110 137

Short Circuit Current 1s A 210 360 570 860 1430 2290 3580 5010 7150Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Nominal Cross Section Area mm² 70 95 120 150 185 240 300 400 630

Nominal Conductor Diameter mm 10.3 12.2 13.8 15.1 17.0 19.6 21.9 24.6 32.5

Maximum DC Resistant@20℃ Ω/km 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607 0.0475 0.0286

Continuous Current Rating@45℃ 1 Core A 242 293 339 389 444 522 601 690 890Continuous Current Rating@45℃ 2 Core A 206 249 288 331 444 444 511 587 757Continuous Current Rating@45℃ 3&4 Core A 169 205 237 272 311 365 421 483 623

Short Circuit Current 1s A 10020 13590 17170 21460 26470 34340 42930 57230 90140Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Note: For more than 4-cores, the current ratings may be calculated from the following formula (I I / NN 1

3= ), I1= Current rating for 1-core, N = Number of cores.

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×1.5 1.0 1.1 1.1 9.3 1451×2.5 1.0 1.1 1.1 9.7 1601×4 1.0 1.1 1.1 10.4 2201×6 1.0 1.1 1.1 10.9 2501×10 1.0 1.1 1.2 12.7 310

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 18: NEK606 Offshore & Marine Cables

Fire Resistant Power and Control Cables

16 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×16 1.0 1.1 1.2 13.9 3901×25 1.2 1.1 1.3 16.3 5851×35 1.2 1.1 1.3 17.2 6901×50 1.4 1.1 1.4 19.0 8901×70 1.4 1.1 1.4 20.6 11101×95 1.6 1.1 1.5 23.1 14401×120 1.6 1.2 1.6 25.0 17351×150 1.8 1.2 1.7 27.0 20601×185 2.0 1.2 1.7 29.4 25451×240 2.2 1.2 1.8 32.6 31701×300 2.4 1.2 1.9 35.3 39101×400 2.4 1.4 2.1 41.0 51001×630 2.8 1.4 2.3 48.5 76602×1.5 1.0 1.1 1.2 14.2 3102×2.5 1.0 1.1 1.3 15.1 3602×4 1.0 1.1 1.3 16.6 4702×6 1.0 1.1 1.4 17.9 5552×10 1.0 1.1 1.4 19.9 7052×16 1.0 1.1 1.5 22.5 9852×25 1.2 1.2 1.6 26.4 13602×35 1.2 1.2 1.7 28.4 16202×50 1.4 1.2 1.9 32.4 22902×70 1.4 1.2 2.1 38.0 32602×95 1.6 1.2 2.3 41.6 39102×120 1.6 1.4 2.4 45.3 47102×150 1.8 1.4 2.6 49.7 56702×185 2.0 1.4 2.7 54.3 68402×240 2.2 1.6 3.0 61.5 87902×300 2.4 1.6 3.2 67.8 106303×1.5 1.0 1.1 1.3 14.8 3453×2.5 1.0 1.1 1.3 16.2 4453×4 1.0 1.1 1.3 17.4 5303×6 1.0 1.1 1.4 18.7 6353×10 1.0 1.1 1.5 21.1 8303×16 1.0 1.1 1.5 23.7 11603×25 1.2 1.2 1.7 28.1 16403×35 1.2 1.2 1.8 30.2 19803×50 1.4 1.2 2.0 34.3 27503×70 1.4 1.2 2.2 39.0 36753×95 1.6 1.4 2.4 44.7 4955

Page 19: NEK606 Offshore & Marine Cables

Fire Resistant Power and Control Cables

17ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

3×120 1.6 1.4 2.5 48.3 60353×150 1.8 1.4 2.7 53.2 73553×185 2.0 1.6 2.9 59.5 90253×240 2.2 1.6 3.2 66.5 115903×300 2.4 1.8 3.4 72.6 137404×1.5 1.0 1.1 1.3 16.4 4004×2.5 1.0 1.1 1.3 17.3 5054×4 1.0 1.1 1.4 18.8 6204×6 1.0 1.1 1.4 20.1 7504×10 1.0 1.1 1.5 22.7 9854×16 1.0 1.2 1.6 25.9 14004×25 1.2 1.2 1.8 30.7 19954×35 1.2 1.2 1.9 33.1 24404×50 1.4 1.4 2.0 38.2 34304×70 1.4 1.4 2.2 42.7 46004×95 1.6 1.6 2.4 49.4 61354×120 1.6 1.6 2.5 53.6 75154×150 1.8 1.6 2.9 59.0 90104×185 2.0 1.6 3.1 64.7 110004×240 2.2 1.8 3.4 73.1 141604×300 2.4 1.8 3.7 80.7 175505×1.5 1.0 1.1 1.4 17.7 5106×1.5 1.0 1.1 1.4 19.0 5457×1.5 1.0 1.1 1.4 19.0 5908×1.5 1.0 1.1 1.5 21.8 7159×1.5 1.0 1.1 1.6 23.3 72010×1.5 1.0 1.1 1.6 23.6 79012×1.5 1.0 1.2 1.6 24.3 88014×1.5 1.0 1.2 1.7 25.5 96516×1.5 1.0 1.2 1.7 26.7 103519×1.5 1.0 1.2 1.7 27.4 118520×1.5 1.0 1.2 1.8 29.5 126023×1.5 1.0 1.2 1.9 31.8 143524×1.5 1.0 1.2 2.0 33.2 151027×1.5 1.0 1.2 2.0 33.9 161530×1.5 1.0 1.2 2.0 34.9 173532×1.5 1.0 1.4 2.0 35.5 180033×1.5 1.0 1.4 2.0 36.7 194037×1.5 1.0 1.4 2.0 38.0 209044×1.5 1.0 1.4 2.3 42.6 2460

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 20: NEK606 Offshore & Marine Cables

Fire Resistant Power and Control Cables

18 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

5×2.5 1.0 1.1 1.4 18.8 5956×2.5 1.0 1.1 1.4 20.4 6507×2.5 1.0 1.1 1.4 20.4 7008×2.5 1.0 1.1 1.5 23.5 7909×2.5 1.0 1.1 1.6 25.1 86010×2.5 1.0 1.1 1.6 25.4 95512×2.5 1.0 1.2 1.6 26.1 104514×2.5 1.0 1.2 1.7 27.3 116016×2.5 1.0 1.2 1.8 28.8 126519×2.5 1.0 1.2 1.8 29.6 144520×2.5 1.0 1.2 1.9 31.8 154523×2.5 1.0 1.4 2.0 34.7 180524×2.5 1.0 1.4 2.0 35.8 185027×2.5 1.0 1.4 2.0 35.4 197030×2.5 1.0 1.4 2.1 38.1 223533×2.5 1.0 1.4 2.2 39.6 239037×2.5 1.0 1.4 2.3 41.2 261044×2.5 1.0 1.4 2.4 46.2 3075

Note: For XLPE insulated cable, a thinner insulation thickness is applied.

Page 21: NEK606 Offshore & Marine Cables

Fire Resistant Power and Control Cables

19ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

P17 BU 0.6/1 kV

Applications

These cables are fire resistant, flame retardant, low smoke and halogen free, used for control, power and lighting systems.

Standards

IEC 60092-353

IEC 60092-351

IEC 60092-359

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-2

NEK 606:2004

Construction

Conductors: Tinned annealed stranded copper to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR.Outer Sheath: Halogen free thermosetting compound, SHF2, coloured black.

Electrical Characteristics

Nominal Cross Section Area mm² 1.5 2.5 4 6 10 16 25 35Nominal Conductor Diameter mm 1.6 2.1 2.6 3.2 4 5.1 6.5 7.4Maximum DC Resistant@20℃ Ω/km 12.2 7.56 4.7 3.11 1.84 1.16 0.734 0.529Continuous Current Rating@45℃ 1 Core A 23 30 40 52 72 96 127 157Continuous Current Rating@45℃ 2 Core A 20 26 34 44 61 82 108 133Continuous Current Rating@45℃ 3&4 Core A 16 21 28 36 50 67 89 110

Short Circuit Current 1s A 210 360 570 860 1430 2290 3580 5010Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Mica Tape + HFEPR Insulation

Stranded Copper Conductor

SHF2 Sheath

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 22: NEK606 Offshore & Marine Cables

Fire Resistant Power and Control Cables

20 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Nominal Cross Section Area mm² 50 70 95 120 150 185 240 300Nominal Conductor Diameter mm 8.7 10.3 12.2 13.8 15.1 17.0 19.6 21.9Maximum DC Resistant@20℃ Ω/km 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607Continuous Current Rating@45℃ 1 Core A 196 242 293 339 389 444 522 601Continuous Current Rating@45℃ 2 Core A 167 206 249 288 331 444 444 511Continuous Current Rating@45℃ 3&4 Core A 137 169 205 237 272 311 365 421Short Circuit Current 1s A 7150 10020 13590 17170 21460 26470 34340 42930Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Note: For more than 4-cores, the current ratings may be calculated from the following formula (I I / NN 1

3= ), I1= Current rating for 1-core, N = Number of cores.

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1×1.5 1.0 1.0 6.4 651×2.5 1.0 1.0 6.8 751×4 1.0 1.0 7.4 951×6 1.0 1.0 7.9 1201×10 1.0 1.1 8.8 1701×16 1.0 1.1 10.2 2401×25 1.2 1.2 12.0 3601×35 1.2 1.2 13.1 4551×50 1.4 1.3 14.7 6001×70 1.4 1.4 16.6 8051×95 1.6 1.5 19.0 10951×120 1.6 1.5 20.6 13451×150 1.8 1.6 22.7 16351×185 2.0 1.7 25.2 2070

Page 23: NEK606 Offshore & Marine Cables

Fire Resistant Power and Control Cables

21ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1×240 2.2 1.8 28.4 26551×300 2.4 1.9 31.1 33352×1.5 1.0 1.1 10.3 1552×2.5 1.0 1.2 11.0 1902×4 1.0 1.2 12.3 2502×6 1.0 1.3 13.4 3102×10 1.0 1.3 15.6 4452×16 1.0 1.4 18.2 6352×25 1.2 1.6 22.0 9702×35 1.2 1.7 24.0 12152×50 1.4 1.8 27.4 16152×70 1.4 1.9 32.6 23352×95 1.6 2.1 37.6 31552×120 1.6 2.3 41.2 38752×150 1.8 2.4 45.4 47252×185 2.0 2.6 50.2 58452×240 2.2 2.8 56.8 75702×300 2.4 3.1 63.0 93953×1.5 1.0 1.2 10.9 1803×2.5 1.0 1.2 11.9 2303×4 1.0 1.2 13.1 2953×6 1.0 1.3 14.2 3753×10 1.0 1.4 16.5 5503×16 1.0 1.5 19.3 7953×25 1.2 1.6 23.5 12203×35 1.2 1.7 25.6 15453×50 1.4 1.9 29.5 20753×70 1.4 2.0 33.2 27753×95 1.6 2.2 38.5 38003×120 1.6 2.4 42.0 46853×150 1.8 2.5 46.3 56853×185 2.0 2.7 51.8 72153×240 2.2 3.0 58.0 93203×300 2.4 3.2 67.6 122804×1.5 1.0 1.2 12.1 2254×2.5 1.0 1.2 13.0 2754×4 1.0 1.3 14.5 3654×6 1.0 1.4 15.8 4904×10 1.0 1.4 18.4 6954×16 1.0 1.5 21.5 10054×25 1.2 1.7 26.1 15504×35 1.2 1.8 28.5 19704×50 1.4 2.0 32.8 26454×70 1.4 2.2 36.9 3545

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 24: NEK606 Offshore & Marine Cables

Fire Resistant Power and Control Cables

22 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

4×95 1.6 2.4 42.8 48504×120 1.6 2.6 46.5 59654×150 1.8 2.8 54.6 80204×185 2.0 3.0 60.3 99304×240 2.2 3.3 68.4 129204×300 2.4 3.5 75.5 159955×1.5 1.0 1.3 14.3 2656×1.5 1.0 1.3 15.6 3057×1.5 1.0 1.3 15.6 3208×1.5 1.0 1.4 18.4 4259×1.5 1.0 1.5 19.9 44010×1.5 1.0 1.5 20.2 49512×1.5 1.0 1.5 20.9 53014×1.5 1.0 1.6 21.9 63016×1.5 1.0 1.6 23.3 69019×1.5 1.0 1.6 24.6 79020×1.5 1.0 1.7 26.1 88023×1.5 1.0 1.8 28.4 103024×1.5 1.0 1.8 29.2 103527×1.5 1.0 1.8 29.9 108030×1.5 1.0 1.9 31.1 125033×1.5 1.0 1.9 32.3 133537×1.5 1.0 2.0 33.8 144544×1.5 1.0 2.2 38.4 17655×2.5 1.0 1.3 14.5 3406×2.5 1.0 1.4 17.0 3957×2.5 1.0 1.4 17.0 4208×2.5 1.0 1.5 20.0 5359×2.5 1.0 1.5 21.5 56010×2.5 1.0 1.5 21.8 62012×2.5 1.0 1.6 22.7 68014×2.5 1.0 1.6 23.9 81016×2.5 1.0 1.7 25.4 89519×2.5 1.0 1.7 26.8 100020×2.5 1.0 1.8 28.4 114023×2.5 1.0 1.9 30.9 132524×2.5 1.0 1.9 31.8 134027×2.5 1.0 1.9 32.5 139530×2.5 1.0 2.0 33.9 162033×2.5 1.0 2.0 35.2 173537×2.5 1.0 2.1 36.8 186544×2.5 1.0 2.3 41.8 2295

Page 25: NEK606 Offshore & Marine Cables

Fire Resistant Power and Control Cables

23ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

P34 BFOU-HCF 0.6/1 kV

Applications

These cables are fire resistant, flame retardant, low smoke and halogen free, used for emergency control, power and lighting systems that need to be operational during a 1100℃ hydrocarbon fire.

Standards

IEC 60092-353

IEC 60092-351

IEC 60092-359

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Tinned annealed stranded compacted copper to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR/XLPE.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath1: Halogen free thermosetting compound, SHF2. HC-fire protection: Extruded thermoplastic fire protection compound.Taping: Lapped glass fibre tape.Outer Sheath2: Flame retardant halogen-free thermoplastic compound, SHF1, coloured black.

SHF2 Sheath

Mica Tape + HFEPR/XLPE InsulationHalogen-free Bedding

Stranded Copper Conductor

SHF1 Sheath

HC-fire Protection + TapingCopper Wire Braid

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 26: NEK606 Offshore & Marine Cables

Fire Resistant Power and Control Cables

24 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Characteristics

Nominal Cross Section Area mm² 1.5 2.5 4 6 16 35Nominal Conductor Diameter mm 1.6 2.1 2.6 3.2 5.1 7.4Maximum DC Resistant@20℃ Ω/km 12.2 7.56 4.7 3.11 1.16 0.529Continuous Current Rating@45℃ 1 Core A 23 30 40 52 96 157Continuous Current Rating@45℃ 2 Core A 20 26 34 44 82 133Continuous Current Rating@45℃ 3&4 Core A 16 21 28 36 67 110Short Circuit Current 1s A 210 360 570 860 2290 5010Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Nominal Cross Section Area mm² 50 70 95 120 150 185 240 300Nominal Conductor Diameter mm 8.7 10.3 12.2 13.8 15.1 17.0 19.6 21.9Maximum DC Resistant@20℃ Ω/km 0.391 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607Continuous Current Rating@45℃ 1 Core A 196 242 293 339 389 444 522 601Continuous Current Rating@45℃ 2 Core A 167 206 249 288 331 444 444 511Continuous Current Rating@45℃ 3&4 Core A 137 169 205 237 272 311 365 421Short Circuit Current 1s A 7150 10020 13590 17170 21460 26470 34340 42930Operating Voltage KV 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1 0.6/1

Note: For more than 4-cores, the current ratings may be calculated from the following formula (I I / NN 1

3= ), I1= Current rating for 1-core, N = Number of cores.

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties

Bending Radius: 20×OD (during installation); 12×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Page 27: NEK606 Offshore & Marine Cables

Fire Resistant Power and Control Cables

25ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Dimensions and Weight

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Diameter Over Bedding

mm

Nominal Diameter Over Sheath1

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1×50 1.4 15.0 18.5 45.5 29001×70 1.4 16.5 20.5 47.5 33001×95 1.6 18.5 23.0 50.5 38001×120 1.6 20.5 25.0 52.5 42601×150 1.8 23.0 27.0 54.5 47501×185 2.0 25.0 29.5 57.5 53801×240 2.2 28.0 32.5 66.0 70501×300 2.4 30.5 35.5 68.0 80002×1.5 1.0 10.0 13.0 40.5 18902×2.5 1.0 11.0 14.5 42.0 20803×1.5 1.0 10.5 14.0 42.0 21403×2.5 1.0 11.5 15.0 42.5 22003×4 1.0 13.0 16.5 43.0 24003×6 1.0 14.0 18.0 45.0 2600

3×16 1.0 18.5 23.0 50.0 35003×35 1.2 25.0 29.5 57.5 48403×70 1.4 33.0 39.0 72.0 81503×120 1.6 41.0 48.0 81.5 113003×150 1.8 46.0 54.5 88.5 133004×2.5 1.0 12.5 16.5 44.0 23004×6 1.0 15.5 19.5 47.5 2870

4×16 1.0 20.5 25.0 53.5 38307×1.5 1.0 14.0 17.5 44.5 2550

12×1.5 1.0 18.5 22.5 50.0 314027×1.5 1.0 26.5 31.0 64.5 50707×2.5 1.0 15.0 19.0 46.0 2760

12×2.5 1.0 20.5 24.5 52.0 3500

Note: For XLPE insulated cable, a thinner insulation thickness is applied.

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 28: NEK606 Offshore & Marine Cables

Medium Voltage Power Cableswww.caledonian-cables.co.uk

P2 or P2/P9 RFOU/TFOU 3.6/6KV

Applications

These cables are flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.

Standards

IEC 60092-354

IEC 60092-351

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P2), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P2/P9), coloured red.

Electrical Characteristics

Nominal Cross Section Area mm² 16 25 35 50 70 95 120Nominal Conductor Diameter mm 5.1 6.5 7.4 8.7 10.3 12.2 13.8

Copper Wire Braid

HFEPR/XLPE Insulation

Halogen-free BeddingStranded Copper Conductor

SHF2/SHF MUD SheathInsulation ScreenConductor Screen

26 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

Page 29: NEK606 Offshore & Marine Cables

Medium Voltage Power Cables

27ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Maximum DC Resistant@20℃ Ω/km 1.16 0.734 0.529 0.391 0.27 0.195 0.154Continuous Current Rating@45℃ 1 Core A 96 127 157 196 242 293 339Continuous Current Rating@45℃ 3 Core A 67 89 110 137 169 205 237Short Circuit Current 1s A 2290 3580 5010 7150 10020 13590 17170Operating Voltage KV 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6

Nominal Cross Section Area mm² 150 185 240 300 400 500 630Nominal Conductor Diameter mm 15.1 17.0 19.6 21.9 24.6 27.6 32.5Maximum DC Resistant@20℃ Ω/km 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Continuous Current Rating@45℃ 1 Core A 389 444 522 601 690 780 890Continuous Current Rating@45℃ 3 Core A 272 311 365 421 483 546 623Short Circuit Current 1s A 21460 26470 34340 42930 57230 71540 90140Operating Voltage KV 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties

Bending Radius: 15×OD (during installation); 9×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×16 2.5 1.4 1.1 22.8 7801×25 2.5 1.5 1.1 24.0 10201×35 2.5 1.5 1.2 25.1 11551×50 2.5 1.6 1.2 26.3 13201×70 2.5 1.6 1.3 28.2 15951×95 2.5 1.7 1.3 30.0 19051×120 2.5 1.8 1.4 31.8 2235

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 30: NEK606 Offshore & Marine Cables

Medium Voltage Power Cables

28 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×150 2.5 1.8 1.4 33.5 25501×185 2.5 1.9 1.5 35.4 30151×240 2.6 2.0 1.5 38.8 37251×300 2.8 2.1 1.6 42.3 46251×400 3.0 2.2 1.7 46.6 54201×500 3.2 2.4 1.8 50.8 66101×630 3.2 2.5 1.9 55.1 81703×16 2.5 2.2 1.6 44.9 29303×25 2.5 2.3 1.7 45.4 33903×35 2.5 2.4 1.8 47.6 38203×50 2.5 2.5 1.9 50.9 44953×70 2.5 2.7 2.0 54.8 55853×95 2.5 2.8 2.1 58.9 67653×120 2.5 3.0 2.2 63.5 81653×150 2.5 3.1 2.3 67.4 94953×185 2.5 3.3 2.4 75.8 106603×240 2.6 3.5 2.5 82.3 116603×300 2.8 3.8 2.7 89.3 12940

Page 31: NEK606 Offshore & Marine Cables

Medium Voltage Power Cables

29ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

P3 or P3/P10 RFOU/TFOU 6/10KV

Applications

These cables are flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.

Standards

IEC 60092-354

IEC 60092-351

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P3), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P3/P10), coloured red.

Electrical Characteristics

Nominal Cross Section Area mm² 16 25 35 50 70 95 120Nominal Conductor Diameter mm 5.2 6.5 7.4 8.7 10.3 12.2 13.8

Copper Wire Braid

HFEPR/XLPE Insulation

Halogen-free BeddingStranded Copper Conductor

SHF2/SHF MUD SheathInsulation ScreenConductor Screen

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 32: NEK606 Offshore & Marine Cables

Medium Voltage Power Cables

30 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Maximum DC Resistant@20℃ Ω/km 1.16 0.734 0.529 0.391 0.27 0.195 0.154Continuous Current Rating@45℃ 1 Core A 96 127 157 196 242 293 339Continuous Current Rating@45℃ 3 Core A 67 89 110 137 169 205 237Short Circuit Current 1s A 2290 3580 5010 7150 10020 13590 17170Operating Voltage KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10

Nominal Cross Section Area mm² 150 185 240 300 400 500 630Nominal Conductor Diameter mm 15.1 17.0 19.6 21.9 24.5 27.5 32.3Maximum DC Resistant@20℃ Ω/km 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Continuous Current Rating@45℃ 1 Core A 389 444 522 601 690 780 890Continuous Current Rating@45℃ 3 Core A 272 311 365 421 483 546 623Short Circuit Current 1s A 21460 26470 34340 42930 57230 71540 90140Operating Voltage KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties

Bending Radius: 15×OD (during installation); 9×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×16 3.4 1.5 1.1 24.0 9001×25 3.4 1.5 1.2 26.0 11401×35 3.4 1.6 1.2 26.9 12651×50 3.4 1.6 1.2 28.3 14601×70 3.4 1.7 1.3 30.0 17101×95 3.4 1.8 1.3 32.0 20601×120 3.4 1.8 1.4 33.8 23801×150 3.4 1.9 1.4 35.3 2700

Page 33: NEK606 Offshore & Marine Cables

Medium Voltage Power Cables

31ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×185 3.4 2.0 1.5 37.8 32251×240 3.4 2.1 1.6 41.0 39901×300 3.4 2.2 1.6 43.7 47601×400 3.4 2.3 1.7 45.5 59001×500 3.4 2.4 1.8 49.5 73501×630 3.4 2.6 1.9 54.5 87503×16 3.4 2.3 1.7 46.0 33003×25 3.4 2.4 1.8 50.1 39053×35 3.4 2.5 1.8 52.2 43603×50 3.4 2.6 1.9 55.1 51853×70 3.4 2.7 2.0 58.9 61253×95 3.4 2.9 2.1 63.5 7500

3×120 3.4 3.0 2.2 67.6 87753×150 3.4 3.2 2.3 71.7 102353×185 3.4 3.4 2.4 74.0 113003×240 3.4 3.6 2.6 79.5 133003×300 3.4 3.8 2.7 85.0 16300

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 34: NEK606 Offshore & Marine Cables

Medium Voltage Power Cables

32 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

P4 or P4/P11 RFOU/TFOU 8.7/15KV

Applications

These cables are flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.

Standards

IEC 60092-354

IEC 60092-351

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P4), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P4/P11), coloured red.

Electrical Characteristics

Nominal Cross Section Area mm² 25 35 50 70 95 120Nominal Conductor Diameter mm 6.5 7.4 8.7 10.3 12.2 13.8

Copper Wire Braid

HFEPR/XLPE Insulation

Halogen-free BeddingStranded Copper Conductor

SHF2/SHF MUD SheathInsulation ScreenConductor Screen

Page 35: NEK606 Offshore & Marine Cables

Medium Voltage Power Cables

33ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Maximum DC Resistant@20℃ Ω/km 0.734 0.529 0.391 0.27 0.195 0.154Continuous Current Rating@45℃ 1 Core A 127 157 196 242 293 339Continuous Current Rating@45℃ 3 Core A 89 110 137 169 205 237Short Circuit Current 1s A 3580 5010 7150 10020 13590 17170Operating Voltage KV 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15

Nominal Cross Section Area mm² 150 185 240 300 400 500 630Nominal Conductor Diameter mm 15.1 17.0 19.6 21.9 24.5 27.5 32.3Maximum DC Resistant@20℃ Ω/km 0.126 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Continuous Current Rating@45℃ 1 Core A 389 444 522 601 690 780 890Continuous Current Rating@45℃ 3 Core A 272 311 365 421 483 546 623Short Circuit Current 1s A 21460 26470 34340 42930 57230 71540 90140Operating Voltage KV 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15 8.7/15

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties

Bending Radius: 15×OD (during installation); 9×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer1×25 4.5 1.6 1.2 28.4 13051×35 4.5 1.6 1.3 29.3 14301×50 4.5 1.7 1.3 30.7 16201×70 4.5 1.8 1.3 32.4 19001×95 4.5 1.8 1.4 34.4 22501×120 4.5 1.9 1.5 36.6 26251×150 4.5 2.0 1.5 38.1 29401×185 4.5 2.0 1.5 40.6 3545

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 36: NEK606 Offshore & Marine Cables

Medium Voltage Power Cables

34 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer1×240 4.5 2.1 1.6 43.4 42201×300 4.5 2.2 1.7 46.3 50701×400 4.5 2.4 1.8 50.2 57601×500 4.5 2.5 1.8 53.6 68801×630 4.5 2.6 1.9 57.9 84603×25 4.5 2.6 1.9 55.3 47253×35 4.5 2.7 2.0 57.5 52153×50 4.5 2.8 2.0 60.6 59603×70 4.5 2.9 2.1 64.4 70353×95 4.5 3.1 2.2 68.7 83703×120 4.5 3.2 2.3 72.7 97453×150 4.5 3.4 2.4 76.8 111403×185 4.5 3.6 2.6 84.2 134903×240 4.5 3.8 2.7 90.6 158603×300 4.5 4.0 2.9 96.6 18320

Page 37: NEK606 Offshore & Marine Cables

Medium Voltage Power Cables

35ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

P19 or P19/P21 RFOU 12/20KV

Applications

These cables are flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.

Standards

IEC 60092-354

IEC 60092-351

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P19), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P19/P21), coloured red.

Optional

P20 or P20/P22 RFOU/TFOU 18/30(36) kV

Copper Wire Braid

HFEPR/XLPE Insulation

Halogen-free BeddingStranded Copper Conductor

SHF2/SHF MUD SheathInsulation ScreenConductor Screen

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 38: NEK606 Offshore & Marine Cables

Medium Voltage Power Cables

36 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Characteristics

Nominal Cross Section Area mm² 16 25 35 50 70 95Nominal Conductor Diameter mm 5.2 6.5 7.4 8.7 10.3 12.2Maximum DC Resistant@20℃ Ω/km 1.16 0.734 0.529 0.391 0.27 0.195Continuous Current Rating@45℃ 1 Core A 96 127 157 196 242 293Continuous Current Rating@45℃ 3 Core A 67 89 110 137 169 205Short Circuit Current 1s A 2290 3580 5010 7150 10020 13590Operating Voltage KV 12/20 12/20 12/20 12/20 12/20 12/20

Nominal Cross Section Area mm² 120 150 185 240 300Nominal Conductor Diameter mm 13.8 15.1 17.0 19.6 21.9Maximum DC Resistant@20℃ Ω/km 0.154 0.126 0.1 0.0762 0.0607Continuous Current Rating@45℃ 1 Core A 339 389 444 522 601Continuous Current Rating@45℃ 3 Core A 237 272 311 365 421Short Circuit Current 1s A 17170 21460 26470 34340 42930Operating Voltage KV 12/20 12/20 12/20 12/20 12/20

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties

Bending Radius: 15×OD (during installation); 9×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer1×16 5.5 1.4 1.2 28 12001×25 5.5 1.5 1.2 31.6 15301×35 5.5 1.8 1.3 32.3 1595

Page 39: NEK606 Offshore & Marine Cables

Medium Voltage Power Cables

37ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer1×50 5.5 1.8 1.4 33.8 17951×70 5.5 1.9 1.4 34.6 20701×95 5.5 2.0 1.5 37.0 24701×120 5.5 2.0 1.5 38.8 28101×150 5.5 2.1 1.6 40.7 32451×185 5.5 2.2 1.6 42.9 37651×240 5.5 2.3 1.7 45.8 45101×300 5.5 2.4 1.8 48.5 53153×16 5.5 1.8 2.0 55.5 49503×25 5.5 1.9 2.0 62.2 57053×35 5.5 2.9 2.1 62.6 59903×50 5.5 3.0 2.2 65.4 67403×70 5.5 3.1 2.3 69.1 77903×95 5.5 3.3 2.4 73.0 91503×120 5.5 3.4 2.5 77.4 105803×150 5.5 3.6 2.6 81.9 121453×185 5.5 3.8 2.7 89.5 122653×240 5.5 4.0 2.9 96.1 147253×300 5.5 4.2 3.0 101.9 17190

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 40: NEK606 Offshore & Marine Cables

Fire Resistant Medium Voltage Power Cables

38 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

P6 or P6/P13 BFOU 3.6/6kV

Applications

These cables are fire resistant, flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.

Standards

IEC 60092-354

IEC 60092-351

IEC 60092-359

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Mica tape + Halogen free EPR. Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P6), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P6/P13), coloured red.

Copper Wire Braid

Mica Tape + HFEPR Insulation

Halogen-free BeddingStranded Copper Conductor

SHF MUD SheathInsulation ScreenConductor Screen

Page 41: NEK606 Offshore & Marine Cables

Fire Resistant Medium Voltage Power Cables

39ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Characteristics

Nominal Cross Section Area mm² 25 35 50 70 95 120 150Nominal Conductor Diameter mm 6.5 7.4 8.7 10.3 12.2 13.8 15.1Maximum DC Resistant@20℃ Ω/km 0.734 0.529 0.391 0.27 0.195 0.154 0.126Continuous Current Rating@45℃ 1 Core A 127 157 196 242 293 339 389Continuous Current Rating@45℃ 3 Core A 89 110 137 169 205 237 272Short Circuit Current 1s A 3580 5010 7150 10020 13590 17170 21460Operating Voltage KV 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6 3.6/6

Nominal Cross Section Area mm² 185 240 300 400 500 630Nominal Conductor Diameter mm 17.0 19.6 21.9 24.5 27.5 32.3Maximum DC Resistant@20℃ Ω/km 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Continuous Current Rating@45℃ 1 Core A 444 522 601 690 780 890Continuous Current Rating@45℃ 3 Core A 311 365 421 483 546 623Short Circuit Current 1s A 26470 34340 42930 57230 71540 90140Operating Voltage KV 3.6/6 3.6/6 3.6/6 8.7/15 8.7/15 8.7/15

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties

Bending Radius: 15×OD (during installation); 9×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×16 2.5 1.5 1.2 24.8 9501×25 2.5 1.6 1.2 26.3 1110

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 42: NEK606 Offshore & Marine Cables

Fire Resistant Medium Voltage Power Cables

40 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×35 2.5 1.6 1.2 27.6 12601×50 2.5 1.7 1.3 29.1 14601×70 2.5 1.7 1.3 30.9 17401×95 2.5 1.8 1.4 33.2 21101×120 2.5 1.9 1.4 34.9 24301×150 2.5 1.9 1.4 36.9 28901×185 2.5 2.0 1.5 39.1 33701×240 2.6 2.1 1.6 42.2 41001×300 2.8 2.2 1.6 44.7 48101×400 3.0 2.3 1.7 48.1 58101×500 3.2 2.5 1.8 52.1 70301×630 3.2 2.6 1.9 56.5 86303×16 2.5 2.3 1.7 48.2 35503×25 2.5 2.5 1.8 51.5 41803×35 2.5 2.6 1.9 54.7 48203×50 2.5 2.7 1.9 57.4 54903×70 2.5 2.8 2.0 61.6 65903×95 2.5 3.0 2.1 66.2 79203×120 2.5 3.1 2.2 70.1 91503×150 2.5 3.3 2.3 74.0 104603×185 2.5 3.4 2.4 78.6 120103×240 2.6 3.7 2.6 86.3 146903×300 2.8 3.9 2.8 92.3 17130

Page 43: NEK606 Offshore & Marine Cables

Fire Resistant Medium Voltage Power Cables

41ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

P7 or P7/P14 BFOU 6/10kV

Applications

These cables are fire resistant, flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.

Standards

IEC 60092-354

IEC 60092-351

IEC 60092-359

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Mica tape + Halogen free EPR. Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE P7), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P7/P14), coloured red.

Copper Wire Braid

Mica Tape + HFEPR Insulation

Halogen-free BeddingStranded Copper Conductor

SHF MUD SheathInsulation ScreenConductor Screen

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 44: NEK606 Offshore & Marine Cables

Fire Resistant Medium Voltage Power Cables

42 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Characteristics

Nominal Cross Section Area mm² 25 35 50 70 95 120 150Nominal Conductor Diameter mm 6.5 7.4 8.7 10.3 12.2 13.8 15.1Maximum DC Resistant@20℃ Ω/km 0.734 0.529 0.391 0.27 0.195 0.154 0.126Continuous Current Rating@45℃ 1 Core A 127 157 196 242 293 339 389Continuous Current Rating@45℃ 3 Core A 89 110 137 169 205 237 272Short Circuit Current 1s A 3580 5010 7150 10020 13590 17170 21460Operating Voltage KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10

Nominal Cross Section Area mm² 185 240 300 400 500 630Nominal Conductor Diameter mm 17.0 19.6 21.9 24.5 27.5 32.3Maximum DC Resistant@20℃ Ω/km 0.1 0.0762 0.0607 0.0475 0.0369 0.0286Continuous Current Rating@45℃ 1 Core A 444 522 601 690 780 890Continuous Current Rating@45℃ 3 Core A 311 365 421 483 546 623Short Circuit Current 1s A 26470 34340 42930 57230 71540 90140Operating Voltage KV 6/10 6/10 6/10 8.7/15 8.7/15 8.7/15

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties

Bending Radius: 15×OD (during installation); 9×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×16 3.4 1.5 1.2 25.6 9901×25 3.4 1.6 1.2 27.1 1150

Page 45: NEK606 Offshore & Marine Cables

Fire Resistant Medium Voltage Power Cables

43ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×35 3.4 1.7 1.2 28.5 13201×50 3.4 1.7 1.3 29.9 15001×70 3.4 1.8 1.3 31.9 18101×95 3.4 1.8 1.4 34.0 21601×120 3.4 1.9 1.4 36.1 26101×150 3.4 2.0 1.5 38.1 29901×185 3.4 2.0 1.5 39.9 34401×240 3.4 2.2 1.6 43.1 41801×300 3.4 2.3 1.7 45.9 49301×400 3.4 2.4 1.7 49.0 59001×500 3.4 2.5 1.8 52.5 70701×630 3.4 2.7 1.9 57.0 86903×16 3.4 2.4 1.8 50.2 37803×25 3.4 2.5 1.8 53.2 43803×35 3.4 2.6 1.9 56.4 50403×50 3.4 2.7 2.0 59.3 57403×70 3.4 2.9 2.1 63.7 69003×95 3.4 3.1 2.2 68.4 82703×120 3.4 3.2 2.3 72.1 94703×150 3.4 3.3 2.4 76.0 108003×185 3.4 3.5 2.5 80.8 123703×240 3.4 3.7 2.7 88.2 150403×300 3.4 3.9 2.9 94.0 17450

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 46: NEK606 Offshore & Marine Cables

Fire Resistant Medium Voltage Power Cables

44 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

P30 RFOU-HCF / TFOU-HCF 6/10(12) kV

Applications

These cables are fire resistant, flame retardant, low smoke and halogen free, used for emergency control, power and lighting systems that need to be operational during a 1100℃ hydrocarbon fire.

Standards

IEC 60092-354

IEC 60092-351

IEC 60092-359

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper to IEC 60228 class 2. Conductor Screen: Semi conducting material. Insulation: Halogen-free EPR. XLPE can be offered as an option.Insulation Screen: Semi conducting material and tinned copper wire braid.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath1: Halogen free thermosetting compound, SHF2, coloured red.HC-fire protection: Extruded thermoplastic fire protection compound.Taping: Lapped glass fibre tape.Outer Sheath2: Flame retardant halogen-free thermoplastic compound, SHF1, coloured red.

Copper Wire Braid

HFEPR/XLPE Insulation

Halogen-free BeddingStranded Copper Conductor

SHF2 SheathInsulation ScreenConductor Screen

SHF1 Sheath

HC-fire Protection + Taping

Page 47: NEK606 Offshore & Marine Cables

Fire Resistant Medium Voltage Power Cables

45ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Optional

P31 RFOU-HCF / TFOU-HCF 8.7/15kVP32 RFOU-HCF / TFOU-HCF 12/20(24) kVP33 RFOU-HCF / TFOU-HCF 18/30(36) kV

Electrical Characteristics

Nominal Cross Section Area mm² 70 95 120 150 185 240 300Nominal Conductor Diameter mm 10.3 12.2 13.8 15.1 17.0 19.6 21.9Maximum DC Resistant@20℃ Ω/km 0.27 0.195 0.154 0.126 0.1 0.0762 0.0607Continuous Current Rating@45℃ 1 Core A 242 293 339 389 444 522 601Continuous Current Rating@45℃ 3 Core A 169 205 237 272 311 365 421Short Circuit Current 1s A 10020 13590 17170 21460 26470 34340 42930Operating Voltage KV 6/10 6/10 6/10 6/10 6/10 6/10 6/10

Ambient Temperature Correction Factors

Ambient Temperature Correction Factors 35 40 45 50 55 60 65 70 75 80Rating Factor 1.1 1.05 1.0 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Mechanical and Thermal Properties

Bending Radius: 20×OD (during installation); 12×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Diameter Over Bedding

mm

Nominal Diameter Over Sheath1

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1×70 3.4 23.5 30.0 62.0 52201×95 3.4 25.5 32.0 64.5 59001×120 3.4 27.5 34.0 66.5 63401×150 3.4 28.5 35.0 67.5 6670

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 48: NEK606 Offshore & Marine Cables

Fire Resistant Medium Voltage Power Cables

46 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of cores×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Diameter Over Bedding

mm

Nominal Diameter Over Sheath1

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1×185 3.4 30.5 36.5 69.0 73201×240 3.4 33.0 39.0 72.0 82501×300 3.4 35.0 41.5 74.5 92803×50 3.4 47.0 55.0 89.0 109703×95 3.4 54.0 62.5 97.0 14230

3×150 3.4 60.0 70.5 106.0 17400

Page 49: NEK606 Offshore & Marine Cables

Instrumentation Cables

47ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

S1 or S1/S5 RFOU(i) 250V

Applications

These cables are flame retardant, low smoke, halogen free and mud resistant, used for instrumentation, communication, control and alarm systems.

Standards

IEC 60092-376

IEC 60092-351

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Halogen free EPR compound.Twinning: Colour coded cores twisted together. Individual Shielding: Each pairs/triples are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE S1). Halogen free MUD resistant thermosetting compound, SHF MUD (for TYPE S1/S5), coloured grey (blue for intrinsically safe).

Copper Wire Braid

HFEPR Insulation

Halogen-free Bedding

Stranded Copper Conductor

SHF2/SHF MUD Sheath

Copper/Polyester Tape + Drain Wire

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 50: NEK606 Offshore & Marine Cables

Instrumentation Cables

48 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Characteristics

Nominal Cross Section Area mm² 0.75 1.0 1.5 2.5Nominal Conductor Diameter mm 1.1 1.3 1.6 2.0Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9 8.02Mutual Capacitance nF/km 90 100 110 120Nominal Inductance@1KHz MH/km 0.686 0.649 0.637 0.598Maximum L/R@1KHz μH/Ω 20 25 35 50Operating Voltage V 250 250 250 250

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores in element×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×2×0.75 0.6 1.1 1.1 10.9 2102×2×0.75 0.6 1.1 1.3 13.2 3254×2×0.75 0.6 1.1 1.3 16.2 4807×2×0.75 0.6 1.1 1.4 19.0 6708×2×0.75 0.6 1.1 1.4 20.4 7559×2×0.75 0.6 1.1 1.5 22.6 835

10×2×0.75 0.6 1.1 1.5 23.5 87512×2×0.75 0.6 1.1 1.5 24.1 101014×2×0.75 0.6 1.1 1.6 25.3 104015×2×0.75 0.6 1.1 1.6 26.9 112016×2×0.75 0.6 1.1 1.6 27.3 116518×2×0.75 0.6 1.1 1.7 28.7 127019×2×0.75 0.6 1.1 1.7 29.0 136020×2×0.75 0.6 1.1 1.7 30.1 142021×2×0.75 0.6 1.1 1.8 31.0 149023×2×0.75 0.6 1.1 1.8 31.5 159524×2×0.75 0.6 1.2 1.8 33.4 172027×2×0.75 0.6 1.2 1.9 34.0 177030×2×0.75 0.6 1.2 1.9 35.1 1910

Page 51: NEK606 Offshore & Marine Cables

Instrumentation Cables

49ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in element×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

32×2×0.75 0.6 1.2 2.0 36.1 206033×2×0.75 0.6 1.2 2.0 36.9 216037×2×0.75 0.6 1.2 2.0 38.0 23301×3×0.75 0.6 1.1 1.2 11.3 2252×3×0.75 0.6 1.1 1.3 16.4 4903×3×0.75 0.6 1.1 1.4 17.2 5204×3×0.75 0.6 1.1 1.4 18.5 6105×3×0.75 0.6 1.1 1.5 19.8 7206×3×0.75 0.6 1.1 1.5 21.7 8357×3×0.75 0.6 1.1 1.5 21.7 8708×3×0.75 0.6 1.1 1.6 23.5 9509×3×0.75 0.6 1.1 1.6 24.6 106510×3×0.75 0.6 1.1 1.7 26.4 109512×3×0.75 0.6 1.1 1.7 27.3 127514×3×0.75 0.6 1.1 1.8 28.5 132015×3×0.75 0.6 1.1 1.8 29.3 139516×3×0.75 0.6 1.1 1.8 30.1 146518×3×0.75 0.6 1.1 1.9 31.6 160019×3×0.75 0.6 1.1 1.9 31.9 165520×3×0.75 0.6 1.2 2.0 33.2 182021×3×0.75 0.6 1.2 2.0 33.8 189023×3×0.75 0.6 1.2 2.0 35.1 205024×3×0.75 0.6 1.2 2.0 36.0 222027×3×0.75 0.6 1.2 2.1 37.9 233530×3×0.75 0.6 1.2 2.2 39.7 255532×3×0.75 0.6 1.2 2.2 40.7 26901×2×1.0 0.6 1.1 1.2 11.4 2302×2×1.0 0.6 1.1 1.3 14.5 3703×2×1.0 0.6 1.1 1.3 16.6 5154×2×1.0 0.6 1.1 1.4 17.4 5955×2×1.0 0.6 1.1 1.4 19.1 6856×2×1.0 0.6 1.1 1.5 20.7 7907×2×1.0 0.6 1.1 1.5 20.7 8208×2×1.0 0.6 1.1 1.6 21.6 8759×2×1.0 0.6 1.1 1.6 23.8 99510×2×1.0 0.6 1.1 1.6 24.8 101012×2×1.0 0.6 1.1 1.7 25.6 119514×2×1.0 0.6 1.1 1.7 26.7 121015×2×1.0 0.6 1.1 1.8 28.5 132016×2×1.0 0.6 1.1 1.8 29.0 137518×2×1.0 0.6 1.1 1.9 30.5 150019×2×1.0 0.6 1.1 1.9 30.8 1555

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 52: NEK606 Offshore & Marine Cables

Instrumentation Cables

50 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in element×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

20×2×1.0 0.6 1.1 1.9 31.9 168021×2×1.0 0.6 1.2 2.0 33.3 179023×2×1.0 0.6 1.2 2.0 33.7 192024×2×1.0 0.6 1.2 2.0 35.2 201527×2×1.0 0.6 1.2 2.1 36.5 218530×2×1.0 0.6 1.2 2.1 37.7 236533×2×1.0 0.6 1.2 2.2 39.2 257037×2×1.0 0.6 1.2 2.2 40.4 27751×3×1.0 0.6 1.1 1.2 11.8 2502×3×1.0 0.6 1.1 1.4 17.3 5553×3×1.0 0.6 1.1 1.4 17.9 5904×3×1.0 0.6 1.1 1.4 19.4 7005×3×1.0 0.6 1.1 1.5 20.7 8256×3×1.0 0.6 1.1 1.6 23.0 9757×3×1.0 0.6 1.1 1.6 23.0 9908×3×1.0 0.6 1.1 1.6 24.4 10959×3×1.0 0.6 1.1 1.7 26.4 1245

10×3×1.0 0.6 1.1 1.8 28.0 126512×3×1.0 0.6 1.1 1.8 28.9 150014×3×1.0 0.6 1.1 1.8 30.0 154515×3×1.0 0.6 1.1 1.9 31.1 165516×3×1.0 0.6 1.1 1.9 31.8 187018×3×1.0 0.6 1.2 2.0 33.9 193519×3×1.0 0.6 1.2 2.0 34.2 204020×3×1.0 0.6 1.2 2.0 35.1 215021×3×1.0 0.6 1.2 2.1 35.9 224523×3×1.0 0.6 1.2 2.1 37.6 252524×3×1.0 0.6 1.2 2.1 38.7 268527×3×1.0 0.6 1.2 2.2 40.3 278530×3×1.0 0.6 1.2 2.3 42.1 305032×3×1.0 0.6 1.2 2.3 43.2 32151×2×1.5 0.7 1.1 1.2 12.4 2702×2×1.5 0.7 1.1 1.4 15.8 4953×2×1.5 0.7 1.1 1.4 17.9 6404×2×1.5 0.7 1.1 1.5 19.5 7155×2×1.5 0.7 1.1 1.5 21.5 8506×2×1.5 0.7 1.1 1.6 23.3 9907×2×1.5 0.7 1.1 1.6 23.3 10308×2×1.5 0.7 1.1 1.7 24.8 11309×2×1.5 0.7 1.1 1.7 26.9 1230

10×2×1.5 0.7 1.1 1.8 28.2 127012×2×1.5 0.7 1.1 1.8 29.3 1375

Page 53: NEK606 Offshore & Marine Cables

Instrumentation Cables

51ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in element×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

14×2×1.5 0.7 1.1 1.8 30.2 152015×2×1.5 0.7 1.2 1.9 32.7 168516×2×1.5 0.7 1.2 2.0 33.4 177518×2×1.5 0.7 1.2 2.0 35.0 192019×2×1.5 0.7 1.2 2.0 35.3 199020×2×1.5 0.7 1.2 2.1 37.2 225521×2×1.5 0.7 1.2 2.1 38.2 234523×2×1.5 0.7 1.2 2.2 39.0 254024×2×1.5 0.7 1.2 2.2 40.7 261027×2×1.5 0.7 1.2 2.3 41.7 277530×2×1.5 0.7 1.2 2.3 43.1 300533×2×1.5 0.7 1.4 2.4 45.1 348037×2×1.5 0.7 1.4 2.5 46.7 36001×3×1.5 0.7 1.1 1.2 13.0 3002×3×1.5 0.7 1.1 1.4 17.5 5103×3×1.5 0.7 1.1 1.5 20.1 7404×3×1.5 0.7 1.1 1.5 21.8 8705×3×1.5 0.7 1.1 1.6 23.3 10456×3×1.5 0.7 1.1 1.7 25.9 12307×3×1.5 0.7 1.1 1.7 26.0 12658×3×1.5 0.7 1.1 1.8 27.8 14059×3×1.5 0.7 1.1 1.8 29.5 1585

10×3×1.5 0.7 1.1 1.9 31.8 168012×3×1.5 0.7 1.2 2.0 33.1 195014×3×1.5 0.7 1.2 2.0 34.6 202015×3×1.5 0.7 1.2 2.0 35.6 214516×3×1.5 0.7 1.2 2.1 36.6 245018×3×1.5 0.7 1.2 2.2 39.2 258019×3×1.5 0.7 1.2 2.2 39.5 267520×3×1.5 0.7 1.2 2.2 40.5 287521×3×1.5 0.7 1.2 2.3 41.5 300023×3×1.5 0.7 1.2 2.3 43.0 326024×3×1.5 0.7 1.4 2.4 44.9 331027×3×1.5 0.7 1.4 2.4 46.4 363530×3×1.5 0.7 1.4 2.5 48.5 398032×3×1.5 0.7 1.4 2.6 50.0 42251×2×2.5 0.7 1.1 1.2 13.3 3202×2×2.5 0.7 1.1 1.4 17.5 5303×2×2.5 0.7 1.1 1.5 20.2 7804×2×2.5 0.7 1.1 1.5 21.5 9005×2×2.5 0.7 1.1 1.6 23.4 10606×2×2.5 0.7 1.1 1.7 25.4 1235

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 54: NEK606 Offshore & Marine Cables

Instrumentation Cables

52 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in element×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

7×2×2.5 0.7 1.1 1.7 25.4 12908×2×2.5 0.7 1.1 1.7 27.5 14009×2×2.5 0.7 1.1 1.8 29.4 1495

10×2×2.5 0.7 1.1 1.9 30.9 159512×2×2.5 0.7 1.1 1.9 31.6 175514×2×2.5 0.7 1.2 2.0 33.6 199015×2×2.5 0.7 1.2 2.1 36.0 216516×2×2.5 0.7 1.2 2.1 36.9 235018×2×2.5 0.7 1.2 2.2 38.9 256519×2×2.5 0.7 1.2 2.2 39.3 266520×2×2.5 0.7 1.2 2.2 40.8 288021×2×2.5 0.7 1.2 2.3 42.1 302023×2×2.5 0.7 1.2 2.3 42.7 325524×2×2.5 0.7 1.4 2.4 45.2 333027×2×2.5 0.7 1.4 2.4 46.1 361530×2×2.5 0.7 1.4 2.5 47.8 395033×2×2.5 0.7 1.4 2.6 49.7 430037×2×2.5 0.7 1.4 2.6 51.2 46701×3×2.5 0.7 1.1 1.3 13.9 3552×3×2.5 0.7 1.1 1.5 20.9 8403×3×2.5 0.7 1.1 1.5 21.6 9454×3×2.5 0.7 1.1 1.6 23.3 11155×3×2.5 0.7 1.1 1.7 25.4 13156×3×2.5 0.7 1.1 1.8 28.3 15557×3×2.5 0.7 1.1 1.8 28.3 16408×3×2.5 0.7 1.1 1.8 30.2 17809×3×2.5 0.7 1.2 1.9 32.6 2055

10×3×2.5 0.7 1.2 2.0 35.1 208012×3×2.5 0.7 1.2 2.1 36.8 243514×3×2.5 0.7 1.2 2.1 38.3 270015×3×2.5 0.7 1.2 2.2 39.7 289516×3×2.5 0.7 1.2 2.2 40.8 305018×3×2.5 0.7 1.2 2.3 42.9 333519×3×2.5 0.7 1.2 2.3 43.3 347020×3×2.5 0.7 1.4 2.4 44.9 378521×3×2.5 0.7 1.4 2.4 45.8 393523×3×2.5 0.7 1.4 2.5 47.7 415024×3×2.5 0.7 1.4 2.5 48.6 430027×3×2.5 0.7 1.4 2.6 51.1 476530×3×2.5 0.7 1.4 2.7 53.5 523532×3×2.5 0.7 1.6 2.8 55.5 5620

Page 55: NEK606 Offshore & Marine Cables

Instrumentation Cables

53ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

S2 or S2/S6 RFOU(c) 250V

Applications

These cables are flame retardant, low smoke, halogen free and mud resistant, used for instrumentation, communication, control and alarm systems.

Standards

IEC 60092-376

IEC 60092-351

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Halogen free EPR compound.Twinning: Colour coded cores twisted together. Collective Shielding: Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE S2). Halogen free MUD resistant thermosetting compound, SHF MUD (for TYPE S2/S6), coloured grey (blue for intrinsically safe).

Copper Wire Braid

HFEPR Insulation

Halogen-free Bedding

Stranded Copper Conductor

SHF2/SHF MUD Sheath

Copper/Polyester Tape + Drain Wire

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 56: NEK606 Offshore & Marine Cables

Instrumentation Cables

54 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Characteristics

Nominal Cross Section Area mm² 0.75 1.0 1.5 2.5Nominal Conductor Diameter mm 1.1 1.3 1.6 2.0Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9 8.02Mutual Capacitance nF/km 80 90 100 110Nominal Inductance@1KHz MH/km 0.682 0.645 0.632 0.593Maximum L/R@1KHz μH/Ω 20 25 35 50Operating Voltage V 250 250 250 250

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores in element×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×2×0.75 0.6 1.1 1.1 11.1 2002×2×0.75 0.6 1.1 1.3 15.0 2953×2×0.75 0.6 1.1 1.3 15.6 3554×2×0.75 0.6 1.1 1.3 16.4 3905×2×0.75 0.6 1.1 1.4 17.8 5406×2×0.75 0.6 1.1 1.4 19.1 6107×2×0.75 0.6 1.1 1.4 19.1 6258×2×0.75 0.6 1.1 1.5 20.7 6809×2×0.75 0.6 1.1 1.5 21.8 745

10×2×0.75 0.6 1.1 1.6 22.9 76012×2×0.75 0.6 1.1 1.6 23.4 81014×2×0.75 0.6 1.1 1.6 24.5 87515×2×0.75 0.6 1.1 1.7 26.1 96016×2×0.75 0.6 1.1 1.7 26.5 101018×2×0.75 0.6 1.1 1.8 27.9 108019×2×0.75 0.6 1.1 1.8 28.2 111520×2×0.75 0.6 1.1 1.8 29.2 121021×2×0.75 0.6 1.1 1.8 30.0 125523×2×0.75 0.6 1.1 1.9 30.6 135524×2×0.75 0.6 1.1 1.9 31.9 1370

Page 57: NEK606 Offshore & Marine Cables

Instrumentation Cables

55ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in element×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

27×2×0.75 0.6 1.2 1.9 32.9 148030×2×0.75 0.6 1.2 2.0 34.1 160533×2×0.75 0.6 1.2 2.0 35.3 172537×2×0.75 0.6 1.2 2.1 36.9 19501×3×0.75 0.6 1.1 1.2 11.7 2302×3×0.75 0.6 1.1 1.3 14.5 3603×3×0.75 0.6 1.1 1.3 16.2 4154×3×0.75 0.6 1.1 1.4 17.6 5405×3×0.75 0.6 1.1 1.4 19.1 6456×3×0.75 0.6 1.1 1.5 21.1 7557×3×0.75 0.6 1.1 1.5 21.1 7808×3×0.75 0.6 1.1 1.6 22.6 8459×3×0.75 0.6 1.1 1.6 23.9 945

10×3×0.75 0.6 1.1 1.7 25.7 96012×3×0.75 0.6 1.1 1.7 26.4 108014×3×0.75 0.6 1.1 1.7 27.5 115015×3×0.75 0.6 1.1 1.8 28.5 123016×3×0.75 0.6 1.1 1.8 29.2 131018×3×0.75 0.6 1.1 1.9 30.7 140519×3×0.75 0.6 1.1 1.9 31.0 147520×3×0.75 0.6 1.1 1.9 31.8 156021×3×0.75 0.6 1.2 1.9 32.7 164023×3×0.75 0.6 1.2 2.0 34.1 179524×3×0.75 0.6 1.2 2.0 34.6 183027×3×0.75 0.6 1.2 2.1 36.8 204030×3×0.75 0.6 1.2 2.1 38.3. 221032×3×0.75 0.6 1.2 2.2 39.5 23451×2×1.0 0.6 1.1 1.2 11.7 2252×2×1.0 0.6 1.1 1.3 13.4 3353×2×1.0 0.6 1.1 1.3 16.3 4704×2×1.0 0.6 1.1 1.4 17.4 5355×2×1.0 0.6 1.1 1.4 18.7 6106×2×1.0 0.6 1.1 1.5 20.2 7007×2×1.0 0.6 1.1 1.5 20.2 7208×2×1.0 0.6 1.1 1.5 21.8 7759×2×1.0 0.6 1.1 1.6 23.2 850

10×2×1.0 0.6 1.1 1.6 24.1 88012×2×1.0 0.6 1.1 1.6 24.7 98014×2×1.0 0.6 1.1 1.7 26.0 103015×2×1.0 0.6 1.1 1.8 27.8 112516×2×1.0 0.6 1.1 1.8 28.2 117518×2×1.0 0.6 1.1 1.8 29.5 125519×2×1.0 0.6 1.1 1.8 29.8 1295

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 58: NEK606 Offshore & Marine Cables

Instrumentation Cables

56 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in element×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

20×2×1.0 0.6 1.1 1.9 31.1 142021×2×1.0 0.6 1.1 1.9 31.9 147523×2×1.0 0.6 1.2 1.9 32.7 161024×2×1.0 0.6 1.2 2.0 34.3 162027×2×1.0 0.6 1.2 2.0 35.0 174530×2×1.0 0.6 1.2 2.1 36.7 198033×2×1.0 0.6 1.2 2.1 38.0 213037×2×1.0 0.6 1.2 2.2 39.3 23051×3×1.0 0.6 1.1 1.2 12.0 2502×3×1.0 0.6 1.1 1.4 17.0 5203×3×1.0 0.6 1.1 1.4 17.4 5404×3×1.0 0.6 1.1 1.4 18.7 6255×3×1.0 0.6 1.1 1.5 20.2 7456×3×1.0 0.6 1.1 1.6 22.4 8757×3×1.0 0.6 1.1 1.6 22.4 9058×3×1.0 0.6 1.1 1.6 23.8 9809×3×1.0 0.6 1.1 1.7 25.4 1080

10×3×1.0 0.6 1.1 1.7 27.1 115012×3×1.0 0.6 1.1 1.8 28.1 126514×3×1.0 0.6 1.1 1.8 29.2 135515×3×1.0 0.6 1.1 1.8 30.1 144016×3×1.0 0.6 1.1 1.9 31.1 157018×3×1.0 0.6 1.2 1.9 32.8 167519×3×1.0 0.6 1.2 2.0 33.3 175020×3×1.0 0.6 1.2 2.0 34.1 188021×3×1.0 0.6 1.2 2.0 34.8 195023×3×1.0 0.6 1.2 2.1 36.6 221524×3×1.0 0.6 1.2 2.1 37.3 220027×3×1.0 0.6 1.2 2.2 39.2 242530×3×1.0 0.6 1.2 2.2 40.8 263032×3×1.0 0.6 1.2 2.3 42.1 27901×2×1.5 0.7 1.1 1.2 12.7 2602×2×1.5 0.7 1.1 1.4 15.4 4203×2×1.5 0.7 1.1 1.4 17.6 5854×2×1.5 0.7 1.1 1.4 18.8 6355×2×1.5 0.7 1.1 1.5 21.1 7706×2×1.5 0.7 1.1 1.6 22.8 8907×2×1.5 0.7 1.1 1.6 22.8 9258×2×1.5 0.7 1.1 1.6 23.7 9759×2×1.5 0.7 1.1 1.7 26.3 1060

10×2×1.5 0.7 1.1 1.7 27.4 113012×2×1.5 0.7 1.1 1.8 28.3 127014×2×1.5 0.7 1.1 1.8 29.5 1325

Page 59: NEK606 Offshore & Marine Cables

Instrumentation Cables

57ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in element×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

15×2×1.5 0.7 1.1 1.9 31.6 144516×2×1.5 0.7 1.1 1.9 32.1 157518×2×1.5 0.7 1.2 2.0 34.2 167019×2×1.5 0.7 1.2 2.0 34.5 176520×2×1.5 0.7 1.2 2.1 36.0 189521×2×1.5 0.7 1.2 2.1 37.3 205023×2×1.5 0.7 1.2 2.1 37.9 218524×2×1.5 0.7 1.2 2.2 39.8 220027×2×1.5 0.7 1.2 2.2 40.6 239030×2×1.5 0.7 1.2 2.3 42.1 260033×2×1.5 0.7 1.2 2.3 43.6 280537×2×1.5 0.7 1.4 2.4 45.4 30801×3×1.5 0.7 1.1 1.2 13.2 2952×3×1.5 0.7 1.1 1.4 17.0 4903×3×1.5 0.7 1.1 1.5 19.5 6854×3×1.5 0.7 1.1 1.5 20.9 7855×3×1.5 0.7 1.1 1.6 21.0 8206×3×1.5 0.7 1.1 1.7 22.8 9607×3×1.5 0.7 1.1 1.7 25.1 11358×3×1.5 0.7 1.1 1.7 27.0 12709×3×1.5 0.7 1.1 1.8 28.9 1445

10×3×1.5 0.7 1.1 1.9 31.1 145012×3×1.5 0.7 1.1 1.9 31.5 171014×3×1.5 0.7 1.2 2.0 33.8 181515×3×1.5 0.7 1.2 2.0 34.8 193016×3×1.5 0.7 1.2 2.1 36.0 211018×3×1.5 0.7 1.2 2.1 38.1 230519×3×1.5 0.7 1.2 2.2 38.6 237520×3×1.5 0.7 1.2 2.2 39.6 258021×3×1.5 0.7 1.2 2.2 40.4 268023×3×1.5 0.7 1.2 2.3 42.0 292524×3×1.5 0.7 1.2 2.3 42.7 314027×3×1.5 0.7 1.4 2.4 45.3 325030×3×1.5 0.7 1.4 2.5 47.4 355532×3×1.5 0.7 1.4 2.5 48.6 37451×2×2.5 0.7 1.1 1.2 13.5 3002×2×2.5 0.7 1.1 1.4 18.9 6503×2×2.5 0.7 1.1 1.5 19.9 7204×2×2.5 0.7 1.1 1.5 21.1 8205×2×2.5 0.7 1.1 1.6 23.0 9656×2×2.5 0.7 1.1 1.6 24.8 11057×2×2.5 0.7 1.1 1.6 24.8 11508×2×2.5 0.7 1.1 1.7 27.0 1255

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 60: NEK606 Offshore & Marine Cables

Instrumentation Cables

58 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in element×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

9×2×2.5 0.7 1.1 1.8 28.8 138510×2×2.5 0.7 1.1 1.8 30.0 143012×2×2.5 0.7 1.3 1.9 31.0 154514×2×2.5 0.7 1.2 1.9 32.7 173015×2×2.5 0.7 1.2 2.0 35.0 188516×2×2.5 0.7 1.2 2.0 35.6 197018×2×2.5 0.7 1.2 2.1 37.9 223519×2×2.5 0.7 1.2 2.1 38.3 231520×2×2.5 0.7 1.2 2.2 39.9 253021×2×2.5 0.7 1.2 2.2 41.0 263023×2×2.5 0.7 1.2 2.3 41.8 275024×2×2.5 0.7 1.2 2.3 43.7 285027×2×2.5 0.7 1.4 2.4 45.1 315030×2×2.5 0.7 1.4 2.5 46.8 343533×2×2.5 0.7 1.4 2.5 48.5 371537×2×2.5 0.7 1.4 2.6 50.2 40401×3×2.5 0.7 1.1 1.3 14.3 3602×3×2.5 0.7 1.1 1.5 20.5 7853×3×2.5 0.7 1.1 1.5 21.2 8754×3×2.5 0.7 1.1 1.6 22.9 10355×3×2.5 0.7 1.1 1.6 24.8 12056×3×2.5 0.7 1.1 1.8 27.8 14307×3×2.5 0.7 1.1 1.8 27.8 15058×3×2.5 0.7 1.1 1.8 29.6 16259×3×2.5 0.7 1.1 1.9 31.7 1855

10×3×2.5 0.7 1.2 2.0 34.4 189012×3×2.5 0.7 1.2 2.0 35.5 211014×3×2.5 0.7 1.2 2.1 37.6 244515×3×2.5 0.7 1.2 2.2 38.9 262016×3×2.5 0.7 1.2 2.2 40.0 275518×3×2.5 0.7 1.2 2.3 42.0 301019×3×2.5 0.7 1.2 2.3 42.4 312520×3×2.5 0.7 1.2 2.3 43.5 336021×3×2.5 0.7 1.4 2.4 44.9 355523×3×2.5 0.7 1.4 2.5 46.7 388524×3×2.5 0.7 1.4 2.5 47.5 387027×3×2.5 0.7 1.4 2.6 50.0 428030×3×2.5 0.7 1.4 2.7 52.3 469532×3×2.5 0.7 1.4 2.7 53.8 4960

Page 61: NEK606 Offshore & Marine Cables

Instrumentation Cables

59ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

P16 IFLI 250 V

Applications

These cables are flame retardant, low smoke and halogen free, used for living, quarter and office areas.

Standards

IEC 60092-376

IEC 60092-351

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular stranded copper wire to IEC 60228 class 2. Insulation: XLPE.Bedding: Halogen free thermoplastic compound.Metal Screen: Longitudinal aluminium tape, thickness 0.2 mm in contact with a stranded copper earth conductor.Outer Sheath: Halogen free thermoplastic compound, SHF1, coloured grey.

Electrical Characteristics

Nominal Cross Section Area mm² 2.5Maximum Resistant@20℃ Ω/km 7.41Continuous Current Rating@45℃ 2 Core A 26Short Circuit Current 1s A 360Operating Voltage V 250

XLPE Insulation

Stranded Copper Conductor

SHF1 Sheath

Halogen Free Thermoplastic Bedding

Aluminium Tape + Earth Conductor

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 62: NEK606 Offshore & Marine Cables

Instrumentation Cables

60 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores in element×Cross

section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

2×1×2.5 0.7 1.1 1.2 10.0 180

Page 63: NEK606 Offshore & Marine Cables

Instrumentation Cables

61ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

S11 RU(i) 250 V

Applications

These unarmoured cables are flame retardant, low smoke and halogen free, used for instrumentation, communication, control and alarm systems.

Standards

IEC 60092-376

IEC 60092-351

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Halogen free EPR compound.Twinning: Colour coded cores twisted together. Individual Shielding: Each pairs/triples are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Outer Sheath: Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).

Electrical Characteristics

Nominal Cross Section Area mm² 0.75 1.0 1.5 2.5Nominal Conductor Diameter mm 1.1 1.3 1.6 2.0

HFEPR Insulation

Stranded Copper Conductor

SHF2 Sheath

Copper/Polyester Tape + Drain Wire

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 64: NEK606 Offshore & Marine Cables

Instrumentation Cables

62 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9 8.02Mutual Capacitance nF/km 90 100 110 120Nominal Inductance@1KHz MH/km 0.686 0.649 0.637 0.598Maximum L/R@1KHz μH/Ω 20 25 35 50Operating Voltage V 250 250 250 250

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1×2×0.75 0.6 1.0 7.6 952×2×0.75 0.6 1.1 9.7 1804×2×0.75 0.6 1.2 12.1 2557×2×0.75 0.6 1.3 14.4 3808×2×0.75 0.6 1.3 15.6 425

12×2×0.75 0.6 1.5 19.0 61016×2×0.75 0.6 1.5 21.0 78519×2×0.75 0.6 1.6 22.4 89524×2×0.75 0.6 1.7 25.6 113532×2×0.75 0.6 1.8 28.4 14401×3×0.75 0.6 1.0 8.0 1102×3×0.75 0.6 1.2 11.0 1803×3×0.75 0.6 1.2 12.7 2654×3×0.75 0.6 1.2 13.8 3257×3×0.75 0.6 1.4 16.7 5008×3×0.75 0.6 1.4 18.0 540

12×3×0.75 0.6 1.6 22.2 81516×3×0.75 0.6 1.6 24.7 104519×3×0.75 0.6 1.7 26.2 120524×3×0.75 0.6 1.9 30.5 15451×2×1.0 0.6 1.0 8.1 1102×2×1.0 0.6 1.1 10.4 2154×2×1.0 0.6 1.2 12.9 3107×2×1.0 0.6 1.4 15.5 4758×2×1.0 0.6 1.4 17.0 540

Page 65: NEK606 Offshore & Marine Cables

Instrumentation Cables

63ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

12×2×1.0 0.6 1.5 20.5 76016×2×1.0 0.6 1.5 22.9 99519×2×1.0 0.6 1.7 24.1 113524×2×1.0 0.6 1.8 27.8 145032×2×1.0 0.6 1.9 30.8 18501×3×1.0 0.6 1.0 8.5 1253×3×1.0 0.6 1.3 13.4 3204×3×1.0 0.6 1.3 14.8 3957×3×1.0 0.6 1.5 17.9 615

12×3×1.0 0.6 1.6 23.7 99016×3×1.0 0.6 1.7 26.5 129519×3×1.0 0.6 1.8 28.0 147524×3×1.0 0.6 2.0 32.6 19001×2×1.5 0.7 1.0 9.1 1402×2×1.5 0.7 1.2 11.7 2804×2×1.5 0.7 1.3 14.9 4107×2×1.5 0.7 1.5 18.0 6358×2×1.5 0.7 1.5 19.7 720

12×2×1.5 0.7 1.6 23.8 101516×2×1.5 0.7 1.6 26.6 133019×2×1.5 0.7 1.9 28.3 152524×2×1.5 0.7 2.0 32.6 194532×2×1.5 0.7 2.2 36.1 24751×3×1.5 0.7 1.0 9.5 1602×3×1.5 0.7 1.3 14.0 2853×3×1.5 0.7 1.3 15.5 4254×3×1.5 0.7 1.3 17.0 5257×3×1.5 0.7 1.6 20.9 8308×3×1.5 0.7 1.6 22.5 900

12×3×1.5 0.7 1.8 27.6 134016×3×1.5 0.7 1.9 31.1 177019×3×1.5 0.7 2.0 32.8 202024×3×1.5 0.7 2.2 38.4 26101×2×2.5 0.7 1.0 9.8 1751×3×2.5 0.7 1.2 10.4 205

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 66: NEK606 Offshore & Marine Cables

Instrumentation Cables

64 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

S12 RU(c) 250 V

Applications

These unarmoured cables are flame retardant, low smoke and halogen free, used for instrumentation, communication, control and alarm systems.

Standards

IEC 60092-376

IEC 60092-351

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Halogen free EPR compound.Twinning: Colour coded cores twisted together. Collective Shielding: Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Outer Sheath: Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).

Electrical Characteristics

Nominal Cross Section Area mm² 0.75 1.0 1.5Nominal Conductor Diameter mm 1.1 1.3 1.6

HFEPR Insulation

Stranded Copper Conductor

SHF2 Sheath

Copper/Polyester Tape + Drain Wire

Page 67: NEK606 Offshore & Marine Cables

Instrumentation Cables

65ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9Mutual Capacitance nF/km 80 90 100Nominal Inductance@1KHz MH/km 0.682 0.645 0.632Maximum L/R@1KHz μH/Ω 20 25 35Operating Voltage V 250 250 250

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

2×2×0.75 0.6 1.1 9.4 1604×2×0.75 0.6 1.1 11.5 2157×2×0.75 0.6 1.3 13.6 3008×2×0.75 0.6 1.3 14.7 34012×2×0.75 0.6 1.4 17.6 46516×2×0.75 0.6 1.5 19.7 59519×2×0.75 0.6 1.5 20.7 66524×2×0.75 0.6 1.7 24.1 85032×2×0.75 0.6 2.0 26.7 10652×3×0.75 0.6 1.1 11.0 1703×3×0.75 0.6 1.1 12.1 2354×3×0.75 0.6 1.2 13.1 2807×3×0.75 0.6 1.4 15.7 4108×3×0.75 0.6 1.4 17.5 49012×3×0.75 0.6 1.5 20.6 64516×3×0.75 0.6 1.6 23.1 83519×3×0.75 0.6 1.7 24.3 94024×3×0.75 0.6 1.8 28.2 12102×2×1.0 0.6 1.1 9.9 1904×2×1.0 0.6 1.1 12.3 2557×2×1.0 0.6 1.3 14.7 3708×2×1.0 0.6 1.3 15.7 410

12×2×1.0 0.6 1.5 18.9 56516×2×1.0 0.6 1.6 21.1 73019×2×1.0 0.6 1.7 22.5 830

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 68: NEK606 Offshore & Marine Cables

Instrumentation Cables

66 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

24×2×1.0 0.6 1.8 25.9 105032×2×1.0 0.6 2.1 28.7 13153×3×1.0 0.6 1.1 12.9 2804×3×1.0 0.6 1.3 14.0 3357×3×1.0 0.6 1.5 16.9 500

12×3×1.0 0.6 1.6 22.1 79516×3×1.0 0.6 1.6 24.8 102519×3×1.0 0.6 1.8 26.3 117524×3×1.0 0.6 2.0 30.4 14902×2×1.5 0.7 1.2 11.3 2504×2×1.5 0.7 1.2 14.1 3457×2×1.5 0.7 1.4 17.2 5158×2×1.5 0.7 1.4 18.4 575

12×2×1.5 0.7 1.6 22.4 81016×2×1.5 0.7 1.7 25.0 104519×2×1.5 0.7 1.8 26.4 117524×2×1.5 0.7 1.9 30.7 150532×2×1.5 0.7 2.2 33.9 18902×3×1.5 0.7 1.2 13.5 2653×3×1.5 0.7 1.2 14.9 3804×3×1.5 0.7 1.3 16.3 4657×3×1.5 0.7 1.5 19.8 7058×3×1.5 0.7 1.5 21.5 820

12×3×1.5 0.7 1.7 26.2 114016×3×1.5 0.7 1.8 29.4 147519×3×1.5 0.7 1.9 30.9 167524×3×1.5 0.7 2.1 36.2 2160

Page 69: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

67ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

S3 or S3/S7 BFOU(i) 250V

Applications

These cables are fire resistant, flame retardant, low smoke, halogen free and mud resistant, used for instrumentation, communication, control and alarm systems.

Standards

IEC 60092-376

IEC 60092-351

IEC 60092-359

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR compound.Twinning: Colour coded cores twisted together. Individual Shielding: Each pairs/triples are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE S3). Halogen free MUD resistant thermosetting compound, SHF MUD (for TYPE S3/S7), coloured grey (blue for intrinsically safe).

Copper Wire Braid

Mica Tape + HFEPR Insulation

Halogen-free Bedding

Stranded Copper Conductor

SHF2 Sheath

Copper/Polyester Tape + Drain Wire

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 70: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

68 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Characteristics

Nominal Cross Section Area mm² 0.75 1.0 1.5 2.5Nominal Conductor Diameter mm 1.1 1.3 1.6 2.0Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9 8.02Mutual Capacitance nF/km 85 95 100 110Nominal Inductance@1KHz MH/km 0.731 0.691 0.673 0.629Maximum L/R@1KHz μH/Ω 20 25 35 55Operating Voltage V 250 250 250 250

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×2×0.75 0.6 1.1 1.2 12.1 2252×2×0.75 0.6 1.1 1.3 16.7 4053×2×0.75 0.6 1.1 1.4 17.5 5404×2×0.75 0.6 1.1 1.4 18.6 6105×2×0.75 0.6 1.1 1.5 20.2 7056×2×0.75 0.6 1.1 1.5 21.7 8057×2×0.75 0.6 1.1 1.5 21.7 8308×2×0.75 0.6 1.1 1.6 23.6 9059×2×0.75 0.6 1.1 1.7 25.1 1000

10×2×0.75 0.6 1.1 1.7 26.2 103012×2×0.75 0.6 1.1 1.7 26.8 114514×2×0.75 0.6 1.1 1.8 28.2 120515×2×0.75 0.6 1.1 1.8 30.0 130516×2×0.75 0.6 1.1 1.9 30.6 141518×2×0.75 0.6 1.1 1.9 32.1 147519×2×0.75 0.6 1.2 1.9 32.7 157520×2×0.75 0.6 1.2 2.0 34.1 170021×2×0.75 0.6 1.2 2.0 35.0 1765

Page 71: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

69ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

23×2×0.75 0.6 1.2 2.0 35.5 189524×2×0.75 0.6 1.2 2.1 37.7 198027×2×0.75 0.6 1.2 2.2 38.7 216530×2×0.75 0.6 1.2 2.2 39.9 233533×2×0.75 0.6 1.2 2.3 41.5 253537×2×0.75 0.6 1.2 2.3 42.7 27251×3×0.75 0.6 1.1 1.1 11.9 2452×3×0.75 0.6 1.1 1.4 15.5 4203×3×0.75 0.6 1.1 1.4 18.4 5804×3×0.75 0.6 1.1 1.4 19.7 6757×3×0.75 0.6 1.1 1.6 23.6 9608×3×0.75 0.6 1.1 1.7 25.0 980

12×3×0.75 0.6 1.3 1.8 29.6 143516×3×0.75 0.6 1.4 1.9 32.6 177019×3×0.75 0.6 1.4 2.1 34.4 198524×3×0.75 0.6 1.8 2.2 39.6 2580

1×2×1.0 0.6 1.1 1.2 12.5 2452×2×1.0 0.6 1.1 1.4 17.6 4503×2×1.0 0.6 1.1 1.4 18.3 6004×2×1.0 0.6 1.1 1.4 19.3 6255×2×1.0 0.6 1.1 1.5 21.1 9206×2×1.0 0.6 1.1 1.6 22.8 9507×2×1.0 0.6 1.1 1.6 22.8 8608×2×1.0 0.6 1.1 1.6 24.7 9859×2×1.0 0.6 1.1 1.7 26.3 1135

10×2×1.0 0.6 1.1 1.7 27.4 117012×2×1.0 0.6 1.1 1.8 28.3 130014×2×1.0 0.6 1.1 1.8 29.5 138015×2×1.0 0.6 1.1 1.9 31.6 151016×2×1.0 0.6 1.1 1.9 32.1 162018×2×1.0 0.6 1.2 2.0 34.2 174519×2×1.0 0.6 1.2 2.0 34.5 183020×2×1.0 0.6 1.2 2.1 36.0 197521×2×1.0 0.6 1.2 2.1 37.3 213523×2×1.0 0.6 1.2 2.1 37.9 229524×2×1.0 0.6 1.2 2.2 39.8 233527×2×1.0 0.6 1.2 2.2 40.6 250030×2×1.0 0.6 1.2 2.3 42.1 272033×2×1.0 0.6 1.2 2.3 43.6 294037×2×1.0 0.6 1.4 2.4 45.4 3230

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 72: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

70 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

1×3×1.0 0.6 1.1 1.2 12.6 2752×3×1.0 0.6 1.1 1.4 18.8 6403×3×1.0 0.6 1.1 1.5 19.3 6654×3×1.0 0.6 1.1 1.5 20.9 7755×3×1.0 0.6 1.1 1.6 22.8 9656×3×1.0 0.6 1.1 1.7 25.4 11357×3×1.0 0.6 1.1 1.7 25.4 11808×3×1.0 0.6 1.1 1.7 27.0 12709×3×1.0 0.6 1.1 1.8 28.9 1450

10×3×1.0 0.6 1.1 1.9 31.1 145512×3×1.0 0.6 1.1 1.9 32.0 168514×3×1.0 0.6 1.2 2.0 33.8 182015×3×1.0 0.6 1.2 2.0 34.8 193516×3×1.0 0.6 1.2 2.1 36.0 210518×3×1.0 0.6 1.2 2.1 38.1 231019×3×1.0 0.6 1.2 2.2 38.6 235520×3×1.0 0.6 1.2 2.2 39.6 259021×3×1.0 0.6 1.2 2.2 40.4 268523×3×1.0 0.6 1.2 2.3 42.0 293524×3×1.0 0.6 1.2 2.3 42.8 314527×3×1.0 0.6 1.4 2.4 45.3 325530×3×1.0 0.6 1.4 2.5 47.4 356532×3×1.0 0.6 1.4 2.5 48.6 37551×2×1.5 0.7 1.1 1.2 13.5 2952×2×1.5 0.7 1.1 1.4 19.2 5453×2×1.5 0.7 1.1 1.5 20.2 7254×2×1.5 0.7 1.1 1.5 21.5 7705×2×1.5 0.7 1.1 1.6 23.4 9756×2×1.5 0.7 1.1 1.7 25.4 11307×2×1.5 0.7 1.1 1.7 25.4 11708×2×1.5 0.7 1.1 1.7 27.5 12259×2×1.5 0.7 1.1 1.8 29.4 1405

10×2×1.5 0.7 1.1 1.9 30.9 144012×2×1.5 0.7 1.1 1.9 31.6 168014×2×1.5 0.7 1.2 2.0 33.6 175015×2×1.5 0.7 1.2 2.1 36.0 191016×2×1.5 0.7 1.2 2.1 36.9 205518×2×1.5 0.7 1.2 2.2 38.9 226019×2×1.5 0.7 1.2 2.2 39.3 239520×2×1.5 0.7 1.2 2.2 40.8 2540

Page 73: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

71ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

21×2×1.5 0.7 1.2 2.3 42.1 266023×2×1.5 0.7 1.2 2.3 42.7 286524×2×1.5 0.7 1.4 2.4 45.2 308027×2×1.5 0.7 1.4 2.4 46.1 315530×2×1.5 0.7 1.4 2.5 47.8 344032×2×1.5 0.7 1.4 2.6 49.0 368533×2×1.5 0.7 1.4 2.6 49.7 374037×2×1.5 0.7 1.4 2.6 51.2 40401×3×1.5 0.7 1.1 1.3 13.6 3252×3×1.5 0.7 1.1 1.5 18.5 5603×3×1.5 0.7 1.1 1.5 21.4 8004×3×1.5 0.7 1.1 1.6 23.7 9755×3×1.5 0.7 1.1 1.7 25.4 11956×3×1.5 0.7 1.1 1.8 28.3 14057×3×1.5 0.7 1.1 1.8 28.3 14708×3×1.5 0.7 1.1 1.8 30.2 15859×3×1.5 0.7 1.2 1.9 32.6 1835

10×3×1.5 0.7 1.2 2.0 35.1 193512×3×1.5 0.7 1.2 2.1 36.8 211514×3×1.5 0.7 1.2 2.1 38.3 236015×3×1.5 0.7 1.2 2.2 39.7 253016×3×1.5 0.7 1.2 2.2 40.8 277518×3×1.5 0.7 1.2 2.3 42.9 290519×3×1.5 0.7 1.2 2.3 43.3 320020×3×1.5 0.7 1.4 2.4 44.9 330521×3×1.5 0.7 1.4 2.4 45.8 343023×3×1.5 0.7 1.4 2.5 47.7 375524×3×1.5 0.7 1.4 2.5 48.6 392527×3×1.5 0.7 1.4 2.6 51.1 411530×3×1.5 0.7 1.4 2.7 53.5 451032×3×1.5 0.7 1.6 2.8 55.5 48501×2×2.5 0.7 1.1 1.3 14.0 3402×2×2.5 0.7 1.1 1.5 18.5 5603×2×2.5 0.7 1.1 1.5 21.6 8654×2×2.5 0.7 1.1 1.6 23.2 10105×2×2.5 0.7 1.1 1.7 25.3 11856×2×2.5 0.7 1.1 1.7 27.4 13707×2×2.5 0.7 1.1 1.7 27.4 14308×2×2.5 0.7 1.1 1.8 29.9 15609×2×2.5 0.7 1.1 1.9 31.9 1780

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 74: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

72 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

10×2×2.5 0.7 1.2 2.0 33.8 177512×2×2.5 0.7 1.2 2.0 34.6 196514×2×2.5 0.7 1.2 2.1 36.9 227515×2×2.5 0.7 1.2 2.2 39.5 248016×2×2.5 0.7 1.2 2.2 40.1 259018×2×2.5 0.7 1.2 2.3 42.3 282519×2×2.5 0.7 1.2 2.3 42.7 293020×2×2.5 0.7 1.4 2.4 44.8 324021×2×2.5 0.7 1.4 2.4 46.1 337523×2×2.5 0.7 1.4 2.5 46.9 356024×2×2.5 0.7 1.4 2.5 49.1 366027×2×2.5 0.7 1.4 2.6 50.3 400030×2×2.5 0.7 1.4 2.7 52.2 437033×2×2.5 0.7 1.4 2.7 54.1 473537×2×2.5 0.7 1.6 2.8 56.4 52251×3×2.5 0.7 1.1 1.2 14.5 3802×3×2.5 0.7 1.1 1.6 22.5 9503×3×2.5 0.7 1.1 1.6 23.4 10554×3×2.5 0.7 1.1 1.7 25.3 12505×3×2.5 0.7 1.1 1.7 27.4 14606×3×2.5 0.7 1.1 1.9 30.7 17357×3×2.5 0.7 1.1 1.9 30.7 18308×3×2.5 0.7 1.2 2.0 33.3 20259×3×2.5 0.7 1.2 2.0 35.4 2290

10×3×2.5 0.7 1.2 2.2 38.8 240512×3×2.5 0.7 1.2 2.2 40.0 268514×3×2.5 0.7 1.2 2.3 41.9 300015×3×2.5 0.7 1.2 2.3 43.1 319016×3×2.5 0.7 1.4 2.4 44.9 342018×3×2.5 0.7 1.4 2.5 47.2 374019×3×2.5 0.7 1.4 2.5 47.6 388520×3×2.5 0.7 1.4 2.5 48.9 418521×3×2.5 0.7 1.4 2.6 50.0 437023×3×2.5 0.7 1.4 2.7 52.1 476024×3×2.5 0.7 1.4 2.7 53.0 478527×3×2.5 0.7 1.6 2.8 56.2 533530×3×2.5 0.7 1.6 2.9 58.8 585532×3×2.5 0.7 1.6 3.0 60.6 6215

Page 75: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

73ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

S4 or S4/S8 BFOU(c) 250V

Applications

These cables are fire resistant, flame retardant, low smoke, halogen free and mud resistant, used for instrumentation, communication, control and alarm systems.

Standards

IEC 60092-376

IEC 60092-351

IEC 60092-359

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR compound.Twinning: Colour coded cores twisted together. Collective Shielding: Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath: Halogen free thermosetting compound, SHF2 (for TYPE S4). Halogen free MUD resistant thermosetting compound, SHF MUD (for TYPE S4/S8), coloured grey (blue for intrinsically safe).

Copper Wire Braid

Mica Tape + HFEPR Insulation

Halogen-free Bedding

Stranded Copper Conductor

SHF2/SHF MUD Sheath

Copper/Polyester Tape + Drain Wire

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 76: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

74 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Characteristics

Nominal Cross Section Area mm² 0.75 1.0 1.5 2.5Nominal Conductor Diameter mm 1.1 1.3 1.6 2.0Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9 8.02Mutual Capacitance nF/km 75 80 85 95Nominal Inductance@1KHz MH/km 0.727 0.686 0.667 0.623Maximum L/R@1KHz μH/Ω 20 25 35 55Operating Voltage V 250 250 250 250

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer1×2×0.75 0.6 1.1 1.2 12.1 2302×2×0.75 0.6 1.1 1.3 16.4 3403×2×0.75 0.6 1.1 1.4 17.2 4954×2×0.75 0.6 1.1 1.4 18.2 5555×2×0.75 0.6 1.1 1.5 19.8 6406×2×0.75 0.6 1.1 1.5 21.2 7257×2×0.75 0.6 1.1 1.5 21.2 7408×2×0.75 0.6 1.1 1.6 23.1 8059×2×0.75 0.6 1.1 1.6 24.3 880

10×2×0.75 0.6 1.1 1.7 25.6 90012×2×0.75 0.6 1.1 1.7 26.2 95014×2×0.75 0.6 1.1 1.7 27.3 103515×2×0.75 0.6 1.1 1.8 29.2 113016×2×0.75 0.6 1.1 1.8 29.7 117518×2×0.75 0.6 1.1 1.9 31.3 127519×2×0.75 0.6 1.1 1.9 31.6 131520×2×0.75 0.6 1.2 2.0 33.3 147521×2×0.75 0.6 1.2 2.0 34.1 153023×2×0.75 0.6 1.2 2.0 34.6 163524×2×0.75 0.6 1.2 2.1 36.8 1730

Page 77: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

75ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer27×2×0.75 0.6 1.2 2.1 37.5 185030×2×0.75 0.6 1.2 2.2 38.9 196533×2×0.75 0.6 1.2 2.2 40.3 215537×2×0.75 0.6 1.2 2.3 41.7 23251×3×0.75 0.6 1.1 1.2 12.6 2552×3×0.75 0.6 1.1 1.4 17.7 5453×3×0.75 0.6 1.1 1.4 18.3 5854×3×0.75 0.6 1.1 1.5 19.7 6705×3×0.75 0.6 1.1 1.5 21.2 7706×3×0.75 0.6 1.1 1.6 23.5 9007×3×0.75 0.6 1.1 1.6 23.5 9358×3×0.75 0.6 1.1 1.7 25.2 10159×3×0.75 0.6 1.1 1.7 26.7 1135

10×3×0.75 0.6 1.1 1.8 28.7 114012×3×0.75 0.6 1.1 1.8 29.6 123014×3×0.75 0.6 1.1 1.9 31.0 137515×3×0.75 0.6 1.1 1.9 31.9 145516×3×0.75 0.6 1.2 2.0 33.3 154518×3×0.75 0.6 1.2 2.0 34.8 169019×3×0.75 0.6 1.2 2.0 35.1 175020×3×0.75 0.6 1.2 2.1 36.6 198521×3×0.75 0.6 1.2 2.1 37.3 205523×3×0.75 0.6 1.2 2.2 38.8 221524×3×0.75 0.6 1.2 2.2 39.5 224527×3×0.75 0.6 1.2 2.3 41.5 243530×3×0.75 0.6 1.2 2.3 43.3 264532×3×0.75 0.6 1.4 2.4 44.9 28401×2×1.0 0.6 1.1 1.2 12.5 2452×2×1.0 0.6 1.1 1.4 17.2 3753×2×1.0 0.6 1.1 1.4 17.9 5504×2×1.0 0.6 1.1 1.4 19.0 6155×2×1.0 0.6 1.1 1.5 20.6 7106×2×1.0 0.6 1.1 1.6 22.4 8207×2×1.0 0.6 1.1 1.6 22.4 8458×2×1.0 0.6 1.1 1.6 24.1 9059×2×1.0 0.6 1.1 1.7 25.7 99510×2×1.0 0.6 1.1 1.7 26.8 103512×2×1.0 0.6 1.1 1.7 27.4 109514×2×1.0 0.6 1.1 1.8 28.9 119515×2×1.0 0.6 1.1 1.9 30.9 130516×2×1.0 0.6 1.1 1.9 31.4 135518×2×1.0 0.6 1.2 2.0 33.4 150019×2×1.0 0.6 1.2 2.0 33.7 1550

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 78: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

76 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer20×2×1.0 0.6 1.2 2.0 35.0 168521×2×1.0 0.6 1.2 2.1 36.5 185023×2×1.0 0.6 1.2 2.1 37.0 197524×2×1.0 0.6 1.2 2.2 38.9 199027×2×1.0 0.6 1.2 2.2 39.6 213530×2×1.0 0.6 1.2 2.2 40.9 230033×2×1.0 0.6 1.2 2.3 42.5 249537×2×1.0 0.6 1.4 2.4 44.3 27351×3×1.0 0.6 1.1 1.2 13.0 2802×3×1.0 0.6 1.1 1.4 18.0 5503×3×1.0 0.6 1.1 1.4 18.7 6004×3×1.0 0.6 1.1 1.5 20.0 6905×3×1.0 0.6 1.1 1.6 22.4 8806×3×1.0 0.6 1.1 1.6 24.6 10207×3×1.0 0.6 1.1 1.6 24.6 10608×3×1.0 0.6 1.1 1.7 26.4 11509×3×1.0 0.6 1.1 1.8 28.2 1305

10×3×1.0 0.6 1.1 1.8 30.2 129012×3×1.0 0.6 1.1 1.9 31.3 143514×3×1.0 0.6 1.2 1.9 32.9 160515×3×1.0 0.6 1.2 2.0 34.0 172016×3×1.0 0.6 1.2 2.0 35.0 176518×3×1.0 0.6 1.2 2.1 37.2 205019×3×1.0 0.6 1.2 2.1 37.5 212020×3×1.0 0.6 1.2 2.2 38.7 230021×3×1.0 0.6 1.2 2.2 39.4 238023×3×1.0 0.6 1.2 2.2 40.8 251524×3×1.0 0.6 1.2 2.3 41.7 257527×3×1.0 0.6 1.2 2.3 43.7 281530×3×1.0 0.6 1.4 2.4 46.1 312532×3×1.0 0.6 1.4 2.5 47.5 33101×2×1.5 0.7 1.1 1.3 14.3 3352×2×1.5 0.7 1.1 1.5 20.5 7403×2×1.5 0.7 1.1 1.5 21.2 8054×2×1.5 0.7 1.1 1.6 22.9 9455×2×1.5 0.7 1.1 1.6 24.8 10956×2×1.5 0.7 1.1 1.8 27.8 13007×2×1.5 0.7 1.1 1.8 27.8 13558×2×1.5 0.7 1.1 1.8 29.6 14559×2×1.5 0.7 1.1 1.9 31.7 1660

10×2×1.5 0.7 1.1 2.0 34.4 168012×2×1.5 0.7 1.1 2.0 35.5 185514×2×1.5 0.7 1.2 2.1 37.6 2150

Page 79: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

77ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer15×2×1.5 0.7 1.2 2.2 38.9 230016×2×1.5 0.7 1.2 2.2 40.0 241518×2×1.5 0.7 1.2 2.3 42.0 263019×2×1.5 0.7 1.2 2.3 42.4 272520×2×1.5 0.7 1.2 2.3 43.5 294021×2×1.5 0.7 1.2 2.4 44.9 311023×2×1.5 0.7 1.2 2.5 46.7 340024×2×1.5 0.7 1.2 2.5 47.5 336027×2×1.5 0.7 1.4 2.6 50.0 371030×2×1.5 0.7 1.4 2.7 52.3 406032×2×1.5 0.7 1.4 2.7 53.8 428533×2×1.5 0.7 1.4 2.5 48.5 324537×2×1.5 0.7 1.4 2.6 50.2 35151×3×1.5 0.7 1.1 1.3 14.3 3352×3×1.5 0.7 1.1 1.5 20.5 7403×3×1.5 0.7 1.1 1.5 21.2 8054×3×1.5 0.7 1.1 1.6 22.9 9455×3×1.5 0.7 1.1 1.6 24.8 10956×3×1.5 0.7 1.1 1.8 27.8 13007×3×1.5 0.7 1.1 1.8 27.8 13558×3×1.5 0.7 1.1 1.8 29.6 14559×3×1.5 0.7 1.1 1.9 31.7 1660

10×3×1.5 0.7 1.2 2.0 34.4 168012×3×1.5 0.7 1.2 2.0 35.5 185514×3×1.5 0.7 1.2 2.1 37.6 215015×3×1.5 0.7 1.2 2.2 38.9 230016×3×1.5 0.7 1.2 2.2 40.0 240518×3×1.5 0.7 1.2 2.3 42.0 263019×3×1.5 0.7 1.2 2.3 42.4 271020×3×1.5 0.7 1.2 2.3 43.5 294021×3×1.5 0.7 1.4 2.4 44.9 311023×3×1.5 0.7 1.4 2.5 46.7 340024×3×1.5 0.7 1.4 2.5 47.5 343027×3×1.5 0.7 1.4 2.6 50.0 371030×3×1.5 0.7 1.4 2.7 52.3 406032×3×1.5 0.7 1.4 2.7 53.8 42851×2×2.5 0.7 1.1 1.3 14.5 3352×2×2.5 0.7 1.1 1.5 20.4 7403×2×2.5 0.7 1.1 1.5 21.3 8004×2×2.5 0.7 1.1 1.6 22.8 9305×2×2.5 0.7 1.1 1.6 24.7 10756×2×2.5 0.7 1.1 1.7 26.9 12457×2×2.5 0.7 1.1 1.7 26.9 1290

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 80: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

78 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer8×2×2.5 0.7 1.1 1.8 29.3 14059×2×2.5 0.7 1.1 1.9 31.3 1585

10×2×2.5 0.7 1.2 2.0 33.2 160512×2×2.5 0.7 1.2 2.0 34.0 174514×2×2.5 0.7 1.2 2.0 35.6 192015×2×2.5 0.7 1.2 2.2 38.8 220516×2×2.5 0.7 1.2 2.2 39.4 223018×2×2.5 0.7 1.2 2.3 41.5 250019×2×2.5 0.7 1.2 2.3 41.9 259020×2×2.5 0.7 1.2 2.3 43.5 281521×2×2.5 0.7 1.4 2.4 45.2 299023×2×2.5 0.7 1.4 2.4 45.8 321524×2×2.5 0.7 1.4 2.5 48.2 327027×2×2.5 0.7 1.4 2.6 49.4 351530×2×2.5 0.7 1.4 2.6 51.0 381033×2×2.5 0.7 1.4 2.7 53.1 414537×2×2.5 0.7 1.4 2.8 54.9 45001×3×2.5 0.7 1.1 1.3 15.1 3852×3×2.5 0.7 1.1 1.5 22.0 8803×3×2.5 0.7 1.1 1.6 23.0 9904×3×2.5 0.7 1.1 1.6 24.6 11505×3×2.5 0.7 1.1 1.7 26.9 13506×3×2.5 0.7 1.1 1.8 30.0 15957×3×2.5 0.7 1.1 1.8 30.0 16708×3×2.5 0.7 1.1 1.9 32.2 18209×3×2.5 0.7 1.2 2.0 34.8 210510×3×2.5 0.7 1.2 2.1 37.9 219012×3×2.5 0.7 1.2 2.2 39.2 245514×3×2.5 0.7 1.2 2.2 40.9 271515×3×2.5 0.7 1.2 2.3 42.3 290516×3×2.5 0.7 1.2 2.3 43.5 306018×3×2.5 0.7 1.4 2.4 46.1 338019×3×2.5 0.7 1.4 2.5 46.7 353020×3×2.5 0.7 1.4 2.5 47.9 380021×3×2.5 0.7 1.4 2.5 48.9 395023×3×2.5 0.7 1.4 2.6 50.9 429024×3×2.5 0.7 1.4 2.6 51.8 432527×3×2.5 0.7 1.4 2.7 54.5 474530×3×2.5 0.7 1.6 2.9 57.7 530032×3×2.5 0.7 1.6 2.9 59.3 5595

Page 81: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

79ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

S13 BU(i) 250 V

Applications

These cables are fire resistant, flame retardant, low smoke and halogen free, used for instrumentation, communication, control and alarm systems.

Standards

IEC 60092-376

IEC 60092-351

IEC 60092-359

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR compound.Twinning: Colour coded cores twisted together. Individual Shielding: Each pairs/triples are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Outer Sheath: Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).

Mica Tape + HFEPR Insulation

Stranded Copper Conductor

SHF2 Sheath

Copper/Polyester Tape + Drain Wire

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 82: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

80 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Characteristics

Nominal Cross Section Area mm² 0.75 1.0 1.5 2.5Nominal Conductor Diameter mm 1.1 1.3 1.6 2.0Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9 8.02Mutual Capacitance nF/km 85 95 100 110Nominal Inductance@1KHz MH/km 0.731 0.691 0.673 0.629Maximum L/R@1KHz μH/Ω 20 25 35 55Operating Voltage V 250 250 250 250

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1×2×0.75 0.6 1.0 8.2 1052×2×0.75 0.6 1.2 10.5 2054×2×0.75 0.6 1.2 13.2 2907×2×0.75 0.6 1.4 16.0 4458×2×0.75 0.6 1.4 17.3 495

12×2×0.75 0.6 1.6 21.1 70516×2×0.75 0.6 1.7 23.5 91519×2×0.75 0.6 1.8 24.8 103524×2×0.75 0.6 1.9 28.6 132032×2×0.75 0.6 2.0 31.7 16701×3×0.75 0.6 1.0 8.6 1202×3×0.75 0.6 1.2 12.0 2053×3×0.75 0.6 1.2 13.8 3004×3×0.75 0.6 1.3 15.1 3657×3×0.75 0.6 1.5 18.3 5608×3×0.75 0.6 1.5 19.5 650

12×3×0.75 0.6 1.7 24.4 91516×3×0.75 0.6 1.8 27.3 118519×3×0.75 0.6 1.9 29.0 136024×3×0.75 0.6 2.1 33.7 1750

Page 83: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

81ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1×2×1.0 0.6 1.0 8.6 1252×2×1.0 0.6 1.2 11.1 2404×2×1.0 0.6 1.3 14.0 3457×2×1.0 0.6 1.5 16.9 5258×2×1.0 0.6 1.5 18.5 600

12×2×1.0 0.6 1.6 22.3 84016×2×1.0 0.6 1.6 24.9 109519×2×1.0 0.6 1.8 26.5 125524×2×1.0 0.6 1.9 30.5 160532×2×1.0 0.6 2.0 33.8 20301×3×1.0 0.6 1.0 9.1 1403×3×1.0 0.6 1.3 14.7 3604×3×1.0 0.6 1.3 16.1 4407×3×1.0 0.6 1.6 19.7 695

12×3×1.0 0.6 1.7 26.0 111516×3×1.0 0.6 1.8 29.2 145519×3×1.0 0.6 1.9 31.0 167524×3×1.0 0.6 2.1 36.1 21451×2×1.5 0.7 1.0 9.6 1552×2×1.5 0.7 1.3 12.6 3104×2×1.5 0.7 1.4 16.1 4507×2×1.5 0.7 1.6 19.4 6908×2×1.5 0.7 1.6 21.3 780

12×2×1.5 0.7 1.7 25.7 110016×2×1.5 0.7 1.9 28.9 145019×2×1.5 0.7 2.0 30.5 164524×2×1.5 0.7 2.2 35.3 211532×2×1.5 0.7 2.3 39.1 26801×3×1.5 0.7 1.1 10.1 1752×3×1.5 0.7 1.3 14.5 3203×3×1.5 0.7 1.3 16.8 4704×3×1.5 0.7 1.4 18.4 5807×3×1.5 0.7 1.7 22.6 9108×3×1.5 0.7 1.7 23.5 1030

12×3×1.5 0.7 1.9 30.0 147516×3×1.5 0.7 2.0 33.6 192519×3×1.5 0.7 2.1 35.7 221024×3×1.5 0.7 2.4 41.7 28551×2×2.5 0.7 1.1 10.5 1901×3×2.5 0.7 1.3 11.0 220

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 84: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

82 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

S14 BU(c) 250 V

Applications

These unarmoured cables are fire resistant, flame retardant, low smoke and halogen free, used for instrumentation, communication, control and alarm systems.

Standards

IEC 60092-376

IEC 60092-351

IEC 60092-359

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR compound.Twinning: Colour coded cores twisted together. Collective Shielding: Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Outer Sheath: Halogen free thermosetting compound, SHF2, coloured grey (blue for intrinsically safe).

Mica Tape + HFEPR Insulation

Stranded Copper Conductor

SHF2 Sheath

Copper/Polyester Tape + Drain Wire

Page 85: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

83ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Characteristics

Nominal Cross Section Area mm² 0.75 1.0 1.5Nominal Conductor Diameter mm 1.1 1.3 1.6Maximum Resistant@20℃ Ω/km 26.3 19.3 12.9Mutual Capacitance nF/km 75 80 85Nominal Inductance@1KHz MH/km 0.727 0.686 0.667Maximum L/R@1KHz μH/Ω 20 25 35Operating Voltage V 250 250 250

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

2×2×0.75 0.6 1.1 10.2 1854×2×0.75 0.6 1.2 12.5 2407×2×0.75 0.6 1.4 15.0 3508×2×0.75 0.6 1.4 16.3 395

12×2×0.75 0.6 1.5 19.5 54016×2×0.75 0.6 1.6 21.8 69019×2×0.75 0.6 1.7 23.2 78024×2×0.75 0.6 1.8 26.7 98532×2×0.75 0.6 2.1 29.6 12252×3×0.75 0.6 1.2 12.0 2053×3×0.75 0.6 1.2 13.1 2654×3×0.75 0.6 1.3 14.4 3207×3×0.75 0.6 1.3 17.4 4758×3×0.75 0.6 1.5 19.5 590

12×3×0.75 0.6 1.6 22.9 74516×3×0.75 0.6 1.7 25.6 96519×3×0.75 0.6 1.8 27.2 109524×3×0.75 0.6 2.0 31.6 14052×2×1.0 0.6 1.1 10.7 210

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 86: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

84 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

4×2×1.0 0.6 1.1 13.3 2857×2×1.0 0.6 1.4 16.0 4158×2×1.0 0.6 1.4 17.3 465

12×2×1.0 0.6 1.6 20.8 64516×2×1.0 0.6 1.7 23.3 82519×2×1.0 0.6 1.8 24.7 94024×2×1.0 0.6 1.9 28.8 120032×2×1.0 0.6 2.3 31.8 14953×3×1.0 0.6 1.2 14.0 3104×3×1.0 0.6 1.4 15.3 3807×3×1.0 0.6 1.6 18.6 570

12×3×1.0 0.6 1.6 24.4 90016×3×1.0 0.6 1.7 27.3 116019×3×1.0 0.6 1.9 29.0 132524×3×1.0 0.6 2.1 33.7 17002×2×1.5 0.7 1.2 12.1 2754×2×1.5 0.7 1.3 15.2 3807×2×1.5 0.7 1.5 18.4 5658×2×1.5 0.7 1.5 20.0 640

12×2×1.5 0.7 1.7 24.3 89516×2×1.5 0.7 1.8 27.2 115019×2×1.5 0.7 1.9 28.6 129524×2×1.5 0.7 2.1 33.5 167032×2×1.5 0.7 2.3 37.0 20952×3×1.5 0.7 1.3 15.0 3103×3×1.5 0.7 1.3 16.0 4204×3×1.5 0.7 1.4 17.7 5157×3×1.5 0.7 1.6 21.5 7858×3×1.5 0.7 1.6 23.5 930

12×3×1.5 0.7 1.8 28.5 125516×3×1.5 0.7 1.9 31.9 163019×3×1.5 0.7 2.0 33.8 185524×3×1.5 0.7 2.2 39.3 2375

Page 87: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

85ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

S15 BFOU-HCF(i) 250 V

Applications

These cables are fire resistant, flame retardant, low smoke and halogen free, used for emergency instrumentation, communication, control and alarm systems that need to be operational during a 1100℃ hydrocarbon fire.

Standards

IEC 60092-376

IEC 60092-351

IEC 60092-359

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned annealed stranded copper wire to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR compound.Twinning: Colour coded cores twisted together. Individual Shielding: Each pairs/triples are screened by copper backed polyester tape in contact with a stranded tinned copper drain wire and wrapped with polyester tape. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath1: Halogen free thermosetting compound, SHF2.HC-fire protection: Extruded thermoplastic fire protection compound.Taping: Lapped glass fibre tape.

SHF2 Sheath

Mica Tape + HFEPR Insulation

Halogen-free Bedding

Stranded Copper Conductor

SHF1 Sheath

HC-fire Protection + TapingCopper Wire Braid

Copper/polyester Tape + Drain Wire

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 88: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

86 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Outer Sheath2: Flame retardant halogen-free thermoplastic compound, type SHF1, coloured grey (blue for intrinsically safe).

Electrical Characteristics

Nominal Cross Section Area mm² 1.5Nominal Conductor Diameter mm 1.6Maximum Resistant@20℃ Ω/km 12.9Mutual Capacitance nF/km 100Nominal Inductance@1KHz MH/km 0.673Operating Voltage V 250

Mechanical and Thermal Properties

Bending Radius: 20×OD (during installation); 12×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores

in element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Diameter Over

Beddingmm

Nominal Diameter Over

Sheath1mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1×2×1.5 0.7 9.0 13.1 39.5 18802×2×1.5 0.7 13.0 16.8 44.5 24504×2×1.5 0.7 15.0 20.7 47.5 28308×2×1.5 0.7 21.0 26.4 54.0 3690

12×2×1.5 0.7 25.0 31.2 63.0 5200

Page 89: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

87ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

S16 BFOU-HCF(c) 250 V

Applications

These cables are fire resistant, flame retardant, low smoke and halogen free, used for emergency instrumentation, communication, control and alarm systems that need to be operational during a 1100℃ hydrocarbon fire.

Standards

IEC 60092-376

IEC 60092-351

IEC 60092-359

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Circular tinned stranded copper wire to IEC 60228 class 2. Insulation: Mica tape + Halogen free EPR compound.Twinning: Colour coded cores twisted together. Collective Shielding: Pairs/triples are layed up and collectively screened by copper backed polyester tape in contact with a stranded tinned copper drain wire. Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors.Bedding: Halogen free compound.Armour: Tinned copper wire braid.Outer Sheath1: Halogen free thermosetting compound, SHF2.HC-fire protection: Extruded thermoplastic fire protection compound.Taping: Lapped glass fibre tape.

SHF2 Sheath

Mica Tape + HFEPR Insulation

Halogen-free Bedding

Stranded Copper Conductor

SHF1 Sheath

HC-fire Protection + TapingCopper Wire Braid

Copper/polyester Tape + Drain Wire

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 90: NEK606 Offshore & Marine Cables

Fire Resistant Instrumentation Cables

88 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Outer Sheath2: Flame retardant halogen-free thermoplastic compound, type SHF1, coloured grey (blue for intrinsically safe).

Electrical Characteristics

Nominal Cross Section Area mm² 1.5Nominal Conductor Diameter mm 1.6Maximum Resistant@20℃ Ω/km 12.9Mutual Capacitance nF/km 85Nominal Inductance@1KHz MH/km 0.667Operating Voltage V 250

Mechanical and Thermal Properties

Bending Radius: 20×OD (during installation); 12×OD (fixed installed)

Temperature Range: -20℃ ~ +90℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores in

element×Cross section(mm²)

Nominal Insulation Thickness

mm

Nominal Diameter Over

Beddingmm

Nominal Diameter Over

Sheath1mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

2×2×1.5 0.7 13.0 16.4 44.5 24004×2×1.5 0.7 15.0 19.9 46.5 26508×2×1.5 0.7 20.5 25.3 53.0 3570

12×2×1.5 0.7 23.5 29.6 57.0 4160

Page 91: NEK606 Offshore & Marine Cables

Telecommunication Cables

89ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

S9 IYXI(c) 60 V

Applications

These cables are flame retardant, low smoke and halogen free, used for indoor telecommunication.

Standards

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Solid tinned copper, 0.5mm. Insulation: Halogen-free thermoplastic compound PE.Twinning: Colour coded cores twisted together. Pairs are cross-stranded to finished cable or 10 pair units. The units are stranded to 20 - 30 - 50 pair cables. 2 pair is stranded as a star quad.Wrapping: Polyester tape.Collective Shielding: The cable core is screened by copper backed polyester tape in contact with a 0.5mm solid tinned drain wire.Sheath: Halogen-free thermoplastic compound, type SHF1, coloured grey.

Electrical Characteristics

Nominal Conductor Diameter mm 0.5Maximum Resistant@20℃ Ω/km 95Nominal Inductance@1KHz MH/km 0.61Mutual Capacitance 1-pair cable nF/km 90Mutual Capacitance 2-pair cable nF/km 80

Copper/polyester Tape + Drain Wire

Halogen Free PE Insulation

Wrapping Tape

Solid Copper Conductor

SHF1 Sheath

Twisted Pair

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 92: NEK606 Offshore & Marine Cables

Telecommunication Cables

90 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Mutual Capacitance 4-pair and above cable nF/km 70Operating Voltage V 60

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -10℃ ~ +60℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores in

element×Core diameter(mm)

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1×2×0.5 0.2 1.2 5.0 302×2×0.5 0.2 1.2 5.5 354×2×0.5 0.2 1.2 7.0 55

10×2×0.5 0.2 1.5 8.5 9020×2×0.5 0.2 1.5 11.0 14830×2×0.5 0.2 1.5 13.5 21050×2×0.5 0.2 1.5 16.0 320

Page 93: NEK606 Offshore & Marine Cables

Telecommunication Cables

91ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

S10 IYOI(c) 60 V

Applications

These cables are flame retardant, low smoke and halogen free, used for indoor telecommunication.

Standards

IEC 60092-359

IEC 60332-1

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: Solid tinned copper, 0.5mm. Insulation: Halogen-free thermoplastic compound PE.Twinning: Colour coded cores twisted together. Pairs are cross-stranded to finished cable or 10 pair units. The units are stranded to 20 - 30 - 50 pair cables. 2 pair is stranded as a star quad.Wrapping: Polyester tape.Collective Shielding: The cable core is screened by copper backed polyester tape in contact with a 0.5mm solid tinned drain wire.Bedding: Halogen-free thermoplastic compound, type SHF1, coloured grey.Armour: Copper wire braidOuter Sheath: Halogen-free thermoplastic compound, type SHF1, coloured grey.

Electrical Characteristics

Nominal Conductor Diameter mm 0.5Maximum Resistant@20℃ Ω/km 95Nominal Inductance@1KHz MH/km 0.61

Copper/polyester Tape + Drain Wire

Halogen Free PE InsulationWrapping Tape

SHF1 Sheath

Solid Copper Conductor

SHF1 Sheath

Copper Wire Braid

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 94: NEK606 Offshore & Marine Cables

Telecommunication Cables

92 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Mutual Capacitance 1-pair cable nF/km 90Mutual Capacitance 2-pair cable nF/km 80Mutual Capacitance 4-pair and above cable nF/km 70Operating Voltage V 60

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 6×OD (fixed installed)

Temperature Range: -10℃ ~ +60℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores in

element×Core diameter(mm)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer1×2×0.5 0.2 1.2 1.2 8.0 952×2×0.5 0.2 1.2 1.2 9.0 1104×2×0.5 0.2 1.2 1.2 10.0 145

10×2×0.5 0.2 1.5 1.5 12.0 20020×2×0.5 0.2 1.5 1.5 15.0 33030×2×0.5 0.2 1.5 1.5 17.0 43050×2×0.5 0.2 1.5 1.5 20.0 580

Page 95: NEK606 Offshore & Marine Cables

Optical Fibre Cables

93ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

F1 QFCI

Applications

These steel armoured optical fibre cables are flame retardant, low smoke, halogen free and fire resistant, used for communication and emergency systems that need to be operational during fire.

Standards

IEC 60794

IEC 60811-2-1

IEC 60331-25

IEC 60332-3-24

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Fibre Element: Loose tube core design. Central Strength Element: Steel wire or fibre reinforced plastic (FRP).Bedding: Halogen free and flame retardant thermoplastic compound.Armour: Galvanized steel wire braid.Outer Sheath: Halogen free and flame retardant, UV-stabilized, thermoplastic compound, SHF1.

Optional

F4 QFCI-HCF: QFCI-HCF cables are consist of loose tube fibre element, steel wire or FRP central strength element, halogen free and flame retardant thermoplastic bedding, galvanized steel wire braid armour, SHF1 sheath, HC-fire protection, fire resistant tape and SHF1 outer sheath.

Galvanized Steel Wire Braid

Steel Wire/FRP Strength Element

Halogen-free Bedding

Fibre Element

SHF1 Sheath

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 96: NEK606 Offshore & Marine Cables

Optical Fibre Cables

94 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Characteristics

Fibre Type 9/125 50/125 50/125 62.5/125ITU-T type G652.D G651 G651 -IEC11801 Classification OS1 & OS2 OM2 OM3 OM1Core Diameter μm 8.7±0.4 50±3.0 50±3.0 62.5±3.0Cladding Diameter μm 125 ± 1.0 125 ± 2.0 125 ± 2.0 125 ± 2.0Coating Diameter μm 245 ± 10 245 ± 10 245 ± 10 245 ± 10Maximum Attenuation

@850 nm dB/km - 3.0 3.0 3.5@1300 nm dB/km - 1.5 1.0 1.5@1310 nm dB/km 0.36 - - -@1550 nm dB/km 0.22 - - -

Minimum Bandwidth(OFL*)@850 nm MHz.km - 500 1500 200@1300 nm MHz.km - 500 500 600

Maximum Chromatic Dispersion1285-1330 nm ps/nm⋅km 2.8 - - -1550 nm ps/nm⋅km 18 - - -

Zero Dispersion Wavelength nm 1300~1324 - - -

Mechanical and Thermal Properties

Bending Radius: 20×OD (during installation); 10×OD (fixed installed)

Temperature Range: -40℃ ~ +70℃

Dimensions and Weight

No. of FibresConstruction

No. of tubes×No. of fibres in each tube

Number of FillersNominal Loose Tube Diameter

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

2 1×2 5 2.2 13.9 2444 1×4 5 2.2 13.9 2446 3×2 3 2.2 13.9 2448 2×4 4 2.2 13.9 244

10 5×2 1 2.2 13.9 24412 3×4 3 2.2 13.9 24416 4×4 2 2.2 13.9 24420 5×4 1 2.2 13.9 24424 6×4 0 2.2 13.9 24432 4×8 2 2.2 13.9 24440 5×8 1 2.2 13.9 24448 6×8 0 2.2 13.9 244

Page 97: NEK606 Offshore & Marine Cables

Optical Fibre Cables

95ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

F5 QFCB

Applications

These steel armoured optical f ibre cables are f lame retardant, low smoke, halogen free and fire resistant, used for communication and emergency systems that need to be operational during fire.

Standards

IEC 60794

IEC 60811-2-1

IEC 60331-25

IEC 60332-3-24

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Fibre Element: Loose tube core design. Central Strength Element: Steel wire or fibre reinforced plastic (FRP).Bedding: Halogen free and flame retardant thermoplastic compound.Armour: Galvanized steel wire braid.Outer Sheath1: Halogen free and flame retardant, UV-stabilized, thermoplastic compound, SHF1.Outer Sheath2: Mud resistant and halogen-free thermoplastic compound.

Electrical Characteristics

Fibre Type 9/125 50/125 50/125 62.5/125ITU-T type G652.D G651 G651 -IEC11801 Classification OS1 & OS2 OM2 OM3 OM1

Galvanized Steel Wire Braid

Steel Wire/FRP Strength ElementHalogen-free Bedding

Fibre Element

SHF1 Sheath

Mud Resistant & Halogen Free Sheath

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 98: NEK606 Offshore & Marine Cables

Optical Fibre Cables

96 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Core Diameter μm 8.7±0.4 50±3.0 50±3.0 62.5±3.0Cladding Diameter μm 125 ± 1.0 125 ± 2.0 125 ± 2.0 125 ± 2.0Coating Diameter μm 245 ± 10 245 ± 10 245 ± 10 245 ± 10Maximum Attenuation

@850 nm dB/km - 3.0 3.0 3.5@1300 nm dB/km - 1.5 1.0 1.5@1310 nm dB/km 0.36 - - -@1550 nm dB/km 0.22 - - -

Minimum Bandwidth(OFL*)@850 nm MHz.km - 500 1500 200@1300 nm MHz.km - 500 500 600

Maximum Chromatic Dispersion1285-1330 nm ps/nm⋅km 2.8 - - -1550 nm ps/nm⋅km 18 - - -

Zero Dispersion Wavelength nm 1300~1324 - - -

Mechanical and Thermal Properties

Bending Radius: 20×OD (during installation); 10×OD (fixed installed)

Temperature Range: -40℃ ~ +70℃

Dimensions and Weight

No. of FibresConstruction

No. of tubes×No. of fibres in each tube

Number of FillersNominal Loose Tube Diameter

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

2 1×2 5 2.2 15.0 2904 1×4 5 2.2 15.0 2906 3×2 3 2.2 15.0 2908 2×4 4 2.2 15.0 290

10 5×2 1 2.2 15.0 29012 3×4 3 2.2 15.0 29016 4×4 2 2.2 15.0 29020 5×4 1 2.2 15.0 29024 6×4 0 2.2 15.0 29032 4×8 2 2.2 15.0 29040 5×8 1 2.2 15.0 29048 6×8 0 2.2 15.0 290

Page 99: NEK606 Offshore & Marine Cables

Optical Fibre Cables

97ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

F6 AICI

Applications

These optical fibre cables are fire resistant, flame retardant, low smoke and halogen free, used for instrumentation, data and communication systems.

Standards

IEC 60794

IEC 60811-2-1

IEC 60331-25

IEC 60332-3-24

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Fibre Element: Tight buffered fibres. Central Strength Element: Fibre reinforced plastic (FRP) and/or aramid yarns.Bedding: Halogen free and flame retardant thermoplastic compound.Armour: Galvanized steel wire braid.Outer Sheath: Halogen free and flame retardant, UV-stabilized, thermoplastic compound, SHF1.

Electrical Characteristics

Fibre Type 9/125 50/125 50/125 62.5/125ITU-T type G652.D G651 G651 -IEC11801 Classification OS1 & OS2 OM2 OM3 OM1

Core Diameter μm 8.7±0.4 50±3.0 50±3.0 62.5±3.0Cladding Diameter μm 125 ± 1.0 125 ± 2.0 125 ± 2.0 125 ± 2.0

Galvanized Steel Wire Braid

Aramid Yarns

Halogen-free Bedding

Fibre Element

SHF1 Sheath

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 100: NEK606 Offshore & Marine Cables

Optical Fibre Cables

98 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Coating Diameter μm 245 ± 10 245 ± 10 245 ± 10 245 ± 10Maximum Attenuation

@850 nm dB/km - 3.0 3.0 3.5@1300 nm dB/km - 1.5 1.0 1.5@1310 nm dB/km 0.36 - - -@1550 nm dB/km 0.22 - - -

Minimum Bandwidth(OFL*)@850 nm MHz.km - 500 1500 200@1300 nm MHz.km - 500 500 600

Maximum Chromatic Dispersion1285-1330 nm ps/nm⋅km 2.8 - - -1550 nm ps/nm⋅km 18 - - -

Zero Dispersion Wavelength nm 1300~1324 - - -

Mechanical and Thermal Properties

Bending Radius: 20×OD (during installation); 10×OD (fixed installed)

Temperature Range: -40℃ ~ +70℃

Dimensions and Weight

No. of FibresSecondary Coating

mmNominal Overall Diameter

mmNominal Weight

kg/km

2 0.9 7.8 1004 0.9 8.2 1108 0.9 9.4 125

12 0.9 10.3 14524 0.9 12.0 185

Page 101: NEK606 Offshore & Marine Cables

Data Cables

99ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Cat5E UTP/FTP Armoured Data Cable

Applications

Cat5E Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for basic voice and data installations up to 100 MHz. In addition, these cables are with copper wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable.

Standards

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: 24AWG solid bare copper. Insulation: HDPE.Twinning: Two coloured insulated conductors twisted together to form a pair.Bedding: Flame retardant, low smoke and halogen-free polyolefin, coloured black.Armour: 0.2/0.3mm copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.

Optional

Cat5E F/UTP: These cables have collective shielding of aluminium/Polyester tape with drain wire.

Cat5E SF/UTP: These cables have double collective shieldings of aluminium/Polyester tape & copper wire braid with drain wire.

Copper Wire Braid

HDPE Insulation

FRLSZH Polyolefin Bedding

Solid Copper Conductor

LSZH Polyolefin Sheath

Twisted Pair

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 102: NEK606 Offshore & Marine Cables

Data Cables

100 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Characteristics

AWG 24Nominal Conductor Diameter mm 0.53Maximum DC Resistant@20℃ Ω/100m 9.38Maximum DCR Unbalance % 5Maximum Mutual Capacitance pF/m 55.8Maximum Capacitance Unbalance pF/100m 330Characteristic Impedance@1-100MHz Ω 100+/-15Maximum Propagation Delay Skew ns/100m 45

FREQMHz

Maximum AttenuationdB/100m

Minimum NEXT

dB

Minimum PSNEXT

dB

Minimum ELFEXTdB/100m

Minimum PSELFEXTdB/100m

Minimum RLdB

0.772 1.8 67.0 64.0 66.0 63.0 —1 2.0 65.3 62.3 63.8 60.8 20.04 4.1 56.3 53.3 51.7 48.7 23.08 5.8 51.8 48.8 45.7 42.7 24.510 6.5 50.3 47.3 43.8 40.8 25.016 8.2 47.3 44.3 39.7 36.7 25.020 9.3 45.8 42.8 37.7 34.7 25.025 10.4 44.3 41.3 35.8 32.8 24.3

31.25 11.7 42.9 39.9 33.9 30.9 23.662.5 17.0 38.4 35.4 27.8 24.8 21.5100 22.0 35.3 32.3 23.8 20.8 20.1

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 4×OD (fixed installed)

Temperature Range: -30℃ ~ +75℃

Copper Wire Braid

HDPE Insulation

FRLSZH Polyolefin Bedding

Solid Copper Conductor

LSZH Polyolefin Sheath

AL/polyester Tape + Drain Wire

Page 103: NEK606 Offshore & Marine Cables

Data Cables

101ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Dimensions and Weight

ConstructionNo. of elements×No. of cores in

element×Conductor diameter(mm)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

4×2×0.53 0.2 0.8 1.14 10.1 179

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 104: NEK606 Offshore & Marine Cables

Data Cables

102 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Cat6 UTP/FTP Armoured Data Cable

Applications

Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables are with copper wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable.

Standards

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: 23AWG solid bare copper. Insulation: HDPE.Twinning: Two coloured insulated conductors twisted together to form a pair.Bedding: Flame retardant, low smoke and halogen-free polyolefin, coloured black.Armour: 0.2/0.3mm copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.

Optional

Cat6 F/UTP: These cables have collective shielding of aluminium/Polyester tape with drain wire.

Cat6 SF/UTP: These cables have double collective shieldings of aluminium/Polyester tape & copper wire braid with drain wire.

Copper Wire Braid

HDPE InsulationFRLSZH Polyolefin Bedding

Solid Copper ConductorLSZH Polyolefin Sheath

Twisted Pair

Page 105: NEK606 Offshore & Marine Cables

Data Cables

103ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Characteristics

AWG 23Nominal Conductor Diameter mm 0.58Maximum DC Resistant@20℃ Ω/100m 7.5Maximum DCR Unbalance % 3Maximum Mutual Capacitance pF/m 5.6Maximum Capacitance Unbalance pF/100m 330Characteristic Impedance@1-100MHz Ω 100+/-15Maximum Propagation Delay Skew ns/100m 18

FREQMHz

Maximum AttenuationdB/100m

Minimum NEXT

dB

Minimum PSNEXT

dB

Minimum ELFEXTdB/100m

Minimum PSELFEXTdB/100m

Minimum RLdB

0.772 1.8 76.0 74.0 70.0 67.0 —1 2.0 74.3 72.3 67.8 64.8 20.04 3.8 65.3 63.3 55.7 52.7 23.08 5.3 60.8 58.8 49.7 46.7 24.5

10 6.0 59.3 57.3 47.8 44.8 25.016 7.6 56.3 54.3 43.7 40.7 25.020 8.5 54.8 52.8 41.7 38.7 25.025 9.5 53.3 51.3 39.8 36.8 24.3

31.25 10.7 51.9 49.9 37.9 34.9 23.662.5 15.4 47.4 45.4 31.8 28.8 21.5100 19.8 44.3 42.3 27.8 24.8 20.1155 25.2 41.5 39.5 23.9 20.9 18.8200 29.0 39.8 37.8 21.7 18.7 18.0250 32.8 38.3 36.3 19.8 16.8 17.3

Copper Wire Braid

HDPE Insulation

FRLSZH Polyolefin Bedding

Solid Copper Conductor

LSZH Polyolefin Sheath

Al/polyester Tape + Drain Wire

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 106: NEK606 Offshore & Marine Cables

Data Cables

104 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Mechanical and Thermal Properties

Bending Radius: 8×OD (during installation); 4×OD (fixed installed)

Temperature Range: -30℃ ~ +75℃

Dimensions and Weight

ConstructionNo. of elements×No. of cores in

element×Conductor diameter(mm)

Nominal Insulation Thickness

mm

Nominal Sheath Thicknessmm

Nominal Overall Diameter

mm

Nominal Weightkg/km

Inner Outer

4×2×0.58 0.23 0.8 1.14 11.6 214

Page 107: NEK606 Offshore & Marine Cables

Coaxial Cables

105ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

RG6 Armoured Coaxial Cable

Applications

These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.

Standards

IEC 60092-350

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: 18AWG solid bare copper. Insulation: Foam PE.Shielding1: Al/Polyester/Al tape.Shielding2: Tinned copper braid.Bedding: Low smoke and halogen-free polyolefin, coloured black.Armour: Copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.

Electrical Characteristics

AWG 18Nominal Conductor Diameter mm 1.0Impedance Ω 75+/-5 Nominal Attenuation@100MHz dB/100m 6.9Nominal Attenuation@200MHz dB/100m 9.0Nominal Attenuation@300MHz dB/100m 11.8Nominal Attenuation@400MHz dB/100m 13.1Nominal Attenuation@500MHz dB/100m 15.4Nominal Attenuation@900MHz dB/100m 21.5

Copper Wire BraidFoam PE Insulation

Tinned Copper BraidSolid Copper Conductor

LSZH Polyolefin Sheath

Al/Polyester/Al TapeLSZH Polyolefin Bedding

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 108: NEK606 Offshore & Marine Cables

Coaxial Cables

106 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Nominal Attenuation@1700MHz dB/100m 29.4Capacitance pF/m 53.5Velocity of Propagation % 83Conductor DCR Ω/km 21.4Shield DCR Ω/km 7.5Inductance μH/m 0.32Time Delay ns/m 4

Mechanical and Thermal Properties

Bending Radius: 15×OD

Temperature Range: -30℃ ~ +75℃

Dimensions and Weight

Nominal Inner Conductor Diameter

mm

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1.0 1.8 1.2 11.2 208

Page 109: NEK606 Offshore & Marine Cables

Coaxial Cables

107ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

RG11 Armoured Coaxial Cable

Applications

These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.

Standards

IEC 60092-350

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: 14AWG solid bare copper. Insulation: Foam PE.Shielding1: Al/Polyester/Al tape.Shielding2: Tinned copper braid.Bedding: Low smoke and halogen-free polyolefin, coloured black.Armour: Copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.

Electrical Characteristics

AWG 14Nominal Conductor Diameter mm 1.6Impedance Ω 75+/-5 Nominal Attenuation@100MHz dB/100m 4.5Nominal Attenuation@270MHz dB/100m 7.6Nominal Attenuation@540MHz dB/100m 10.8Nominal Attenuation@750MHz dB/100m 12.8Nominal Attenuation@1000MHz dB/100m 14.8Capacitance pF/m 53.5

Copper Wire BraidFoam PE Insulation

Tinned Copper BraidSolid Copper Conductor

LSZH Polyolefin Sheath

Al/Polyester/Al TapeLSZH Polyolefin Bedding

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 110: NEK606 Offshore & Marine Cables

Coaxial Cables

108 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Velocity of Propagation % 83Conductor DCR Ω/km 8.5Shield DCR Ω/km 12.1Inductance μH/m 0.32Time Delay ns/m 4

Mechanical and Thermal Properties

Bending Radius: 15×OD

Temperature Range: -30℃ ~ +75℃

Dimensions and Weight

Nominal Inner Conductor Diameter

mm

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

1.6 2.7 1.7 15.0 353

Page 111: NEK606 Offshore & Marine Cables

Coaxial Cables

109ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

RG59 Armoured Coaxial Cable

Applications

These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.

Standards

IEC 60092-350

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: 20AWG solid bare copper. Insulation: Foam PE.Shielding1: Al/Polyester/Al tape.Shielding2: Tinned copper braid.Bedding: Low smoke and halogen-free polyolefin, coloured black.Armour: Copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.

Electrical Characteristics

AWG 20Nominal Conductor Diameter mm 0.8Impedance Ω 75+/-5 Nominal Attenuation@100MHz dB/100m 7.6Nominal Attenuation@270MHz dB/100m 12.5Nominal Attenuation@540MHz dB/100m 17.9Nominal Attenuation@720MHz dB/100m 20.9Nominal Attenuation@750MHz dB/100m 21.3Nominal Attenuation@1000MHz dB/100m 24.9

Copper Wire BraidFoam PE Insulation

Tinned Copper BraidSolid Copper Conductor

LSZH Polyolefin Sheath

Al/Polyester/Al TapeLSZH Polyolefin Bedding

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 112: NEK606 Offshore & Marine Cables

Coaxial Cables

110 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Capacitance pF/m 53.5Velocity of Propagation % 83Conductor DCR Ω/km 32.8Shield DCR Ω/km 12.5Inductance μH/m 0.318Time Delay ns/m 4.0

Mechanical and Thermal Properties

Bending Radius: 15×OD

Temperature Range: -30℃ ~ +75℃

Dimensions and Weight

Nominal Inner Conductor Diameter

mm

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

0.8 1.4 1.2 10.0 177

Page 113: NEK606 Offshore & Marine Cables

Coaxial Cables

111ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

RG58 Armoured Coaxial Cable

Applications

These 50Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.

Standards

IEC 60092-350

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: 21AWG tinned copper. Insulation: PE.Shielding: Tinned copper braid.Bedding: Low smoke and halogen-free polyolefin, coloured black.Armour: Copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.

Electrical Characteristics

AWG 21Conductor Construction No./Diameter of Wires -/mm 19/0.18Nominal Conductor Diameter mm 0.89Impedance Ω 50+/-3 Nominal Attenuation@100MHz dB/100m 15.7Nominal Attenuation@200MHz dB/100m 22.3Nominal Attenuation@400MHz dB/100m 32.8Nominal Attenuation@700MHz dB/100m 46.6Nominal Attenuation@900MHz dB/100m 54.1Nominal Attenuation@1000MHz dB/100m 56.1

Copper Wire Braid

PE Insulation

Tinned Copper Braid

Stranded Copper Conductor

LSZH Polyolefin Sheath

LSZH Polyolefin Bedding

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 114: NEK606 Offshore & Marine Cables

Coaxial Cables

112 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Capacitance pF/m 101Velocity of Propagation % 66Conductor DCR Ω/km 35.4Inductance μH/m 0.246Time Delay ns/m 5.0

Mechanical and Thermal Properties

Bending Radius: 15×OD

Temperature Range: -30℃ ~ +75℃

Dimensions and Weight

Nominal Inner Conductor Diameter

mm

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

0.89 1.0 1.14 8.6 149

Page 115: NEK606 Offshore & Marine Cables

Coaxial Cables

113ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

RG213 Armoured Coaxial Cable

Applications

These 50Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.

Standards

IEC 60092-350

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

Conductors: 13AWG bare copper. Insulation: PE.Shielding: Copper braid.Bedding: Low smoke and halogen-free polyolefin, coloured black.Armour: Copper wire braid.Outer Sheath: Low smoke and halogen-free polyolefin.

Electrical Characteristics

AWG 13Conductor Construction No./Diameter of Wires -/mm 7/0.75Nominal Conductor Diameter mm 2.24Impedance Ω 50+/-3 Nominal Attenuation@100MHz dB/100m 7.5Nominal Attenuation@200MHz dB/100m 10.5Nominal Attenuation@400MHz dB/100m 15.1Nominal Attenuation@1000MHz dB/100m 29.5Capacitance pF/m 101Velocity of Propagation % 66

Copper Wire Braid

PE Insulation

Tinned Copper Braid

Stranded Copper Conductor

LSZH Polyolefin Sheath

LSZH Polyolefin Bedding

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 116: NEK606 Offshore & Marine Cables

Coaxial Cables

114 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Conductor DCR Ω/km 5.7Shield DCR Ω/km 3.9Inductance μH/m 0.246Time Delay ns/m 5.0

Mechanical and Thermal Properties

Bending Radius: 15×OD

Temperature Range: -30℃ ~ +75℃

Dimensions and Weight

Nominal Inner Conductor Diameter

mm

Nominal Insulation Thickness

mm

Nominal Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weightkg/km

2.24 2.2 1.14 13.9 379

Page 117: NEK606 Offshore & Marine Cables

Coaxial Cables

115ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Mud Resistant Composite Cable

Applications

These composite cables consist of cat6 data cable & coaxial cable & power cable, with copper wire braid armoured & flame retardant oil&mud resistant outer sheath.

Standards

IEC 60092-359

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2004

Construction

1) 4×2×0.57mm U/UTP Cat6 Data Cable: Conductors: Solid bare copper wire. Insulation: PE.Twinning: Two coloured insulated wire twisted to form a pair.Sheath: Flame retardant LSZH, coloured grey.

2) RG59 Coaxial Cable: Conductors: 0.58mm solid bare copper wire.Insulation: PE.Shielding: Bare copper wire braid.Sheath: Flame retardant LSZH, coloured grey.

3) 3×1.0mm² Power Cable: Conductors: 7/0.44mm stranded bare copper wire. Insulation: XLPE. Coloured Blue, Brown, Green/Yellow.She ath: Flame retardant LSZH, coloured grey

4) Element AssemblyFiller: PP, PVC, PE or LSZH Material.Wrapping: Polyester Tape.

Copper Wire Braid

Polyester TapeCoaxial Cable Element

Power Cable Element

Flame Retardant LSZH Sheath

Data Cable Element

Flame Retardant LSZH Bedding

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 118: NEK606 Offshore & Marine Cables

Coaxial Cables

116 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Bedding: Flame retardant LSZH.Armour: Tinned copper wire braid.Outer Sheath: Oil & mud resistant, flame retardant LSZH, coloured grey.

Dimensions

Cable ConstructionNominal Data Cable

Diameter mm

Nominal Coaxial Cable Diameter

mm

Nominal Power Cable Diameter

mm

Nominal Overall Diameter

mm4×2×0.57mm + RG59 + 3×1.0mm² 6.0 6.2 6.8 21.0

Note: Other construction can be offered opon request.

Page 119: NEK606 Offshore & Marine Cables

Technical Information

117ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Cable Code DesignationA cable code of 2 letters (1. and 4.) or 4 letters is used to describe the construction.For example:

1st Letter: Insulation:B: Fire resistant tape + insulation (Halogen-free)R: Ethylene propylene rubber - EPR T: Cross-linked polyethylene XLPE I: Thermoplastic compound (Halogen-free) U: Halogen-free thermosetting compound EMA or EVA A: Fibre, tight buffered Q: Fibre in loose tube

2nd letter:Inner Sheath:F: Bedding/Inner covering or taping (Halogen-free) Y: Screen (poss. with PE or PP) I: Thermoplastic compound (Halogen-free) SHF1

3rd letter:Armour/Screen:L: Aluminium (laminated to outer sheath) X: No armour O: Copper wire braid (Tinned or bare) A: Strength member of yarn C: Galvanized steel wire braid

4rd letter:Outer Sheath:I: Thermoplastic compound (Halogen-free), SHF1 U: Halogen-free thermosetting compound, SHF2 U: Halogen-free mud resistant thermosetting compound, SHF Mud B*: Halogen-free mud resistant thermoplastic compound *QFCB cables only

Additional Abbreviation for Instrumentation Cables: (c): Collective screen(i): Individual pair or triple screen

RFOU(i)

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 120: NEK606 Offshore & Marine Cables

Technical Information

118 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Standards and Tests

NEK 606-2004 Cables for Offshore Installations halogen-free and/or mud resistant

IEC 60092-350 Electrical installations in ships Part 350: Low-voltage shipboard power cables.

(General construction and test requirements)IEC 60092-351 Electrical installations in ships Part 351: Insulating materials for shipboard power cablesIEC 60092-352 Electrical installations in ships Part 352: Choice and installation of electric cables for

low voltage power systemsIEC 60092-353 Electrical installations in ships Part 353: Single and multicore cables with extruded

solid insulation for rated voltages 0,6/1 and 1,8/3 kVIEC 60092-354 Electrical installations in ships Part 354: Single and three-core power cables with extruded

solid insulation for rated voltages 6 kV up to 30 kV.IEC 60092-359 Electrical installations in ships Part 359: Sheathing materials for shipboard power and

telecommunication cablesIEC 60092-375 Electrical installations in ships Part 375: General instrumentation, control and

communication cablesIEC 60092-376 Electrical installations in ships Part 376: 150/250 V cables for Control and

instrumentation CircuitsIEC 60228 Conductors of insulated cablesIEC 60331-11/12/21/25/31 Fire resisting characteristics of electrical cablesIEC 60332-1/3 Tests on electric cables under fire condition. Part 1: Tests on a single vertical insulated wire or cable. Part 3: Test on bunched wires or cables.IEC 60446 Basic and safety principles for man-machine interface,

marking and identification. Identification of conductors by colours or alphanumericsIEC 60754-1/2 Test on gases evolved during combustion of electric cables IEC 60811 Common test methods for insulating and sheathing

materials of electric cables

IEC 61034-1/2 Measurement of smoke density of electric cables burning under defined conditions. Part 1: Test apparatus Part 2: Test procedure and requirements

Page 121: NEK606 Offshore & Marine Cables

Technical Information

119ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Cable Characteristics

Mud Resistant

The suitability of sheathing materials for use in areas in which the cables are exposed to drilling fluids is heavily dependent upon the type of fluid present. Each type of fluid contains additives which can have a deleterious effect on the sheathing material.

According to NEK 606, the mud resistant cables shall have a SHF Mud sheath that comply with the requirements in IEC 60092-359 for SHF2 and the below specified. The mud resistant cables shall be designed with sheathing compounds suitable for installation and operation in contact with MUD unless otherwise specified.

The MUD resistance test requirements for sheathing compounds SHF Mud are as follows:

Test fluid Temperature DurationTensile Strength & Elongation At Break Variation

Volume Swell Variation

Weight Increase Variation

Mineral oil type - IRM 903

100℃ 7 d 30% 30% 30%

Calcium Bromide Brine (Waterbased)

70℃ 56 d 25% 20% 15%

Carbo Sea (oil based)

70℃ 56 d 25% 20% 15%

Oil Resistance

All thermoset sheathed cables shall be suitable for an oil production installation. The oil resistance properties shall be demonstrated by a test according to IEC 60092-359 SHF2.

Flame Retardance

The cables shall withstand the test specified in IEC 60332-3-10, -22, -23, -24, -25. Single, earth and bonding wires shall withstand the test specified in IEC 60332-1 or IEC 60332-2.

Fire Resistance

Fire resistance cables shall be tested according to IEC 60331-11, -12, -21, -25 and -31.

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 122: NEK606 Offshore & Marine Cables

Technical Information

120 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Hydrocarbon (HCF) Fire Resistant

The purchaser shall specify which of the curves below in Figure 1 or 2 to comply with the HCF test.

The test requires no breakdown for 30 or 60 minutes when connected to operating voltage. Time to breakdown to be considered in agreement with the customer or approval authority.

Content of Halogen

All cables shall be halogen-free according to IEC 60754-1/2.

Smoke Emission

During a cable fire smoke emission shall be kept to a minimum value of 60% according to IEC 61034-1/2.

Fig.1 HC fire curve based on Exxon calcula�ons, which required func�onal security

for 15 minutes

Time in minutes exposed to fire

Fig.2 Interna�onal recognized HC fire curve.

Time in minutes exposed to fire

Tem

pera

ture

in d

eg.C

Tem

pera

ture

in d

eg.C

20

600

820

10001050 1083 1100 1100

20

743

880945

1033 1071 1098 1100

0 10 20 30 40 50 60

0 10 20 30 40 50 60

Page 123: NEK606 Offshore & Marine Cables

Technical Information

121ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Electrical Data

Conductor Resistance

Resistance formula:

R ALt= [Ω]

p=specificresistance,Ω.mm²/mA=conductorarea,mm²L=conductorlength,m

Resistance as a function of temperature:

1 20R R t0 a= + -] g7 A

R0= Resistance at t=20℃t = conductor temperature ℃α=0.00393forcopper

Short circuit ratings

The following short circuit currents are for cables normally operating at a maximum conductortemperatureof90°C.

The theoretical temperature thatarises in theconductorduringashortcircuit,whichisusedasabasisof thecalculation, is250℃. EPR and XLPE insulation are capable of withstandingshorttermtemperaturesupto250°C.

The short circuit currents for copper conductors given in the table are values for one second,forotherdurationsthecurrentmaybecalculatedfromthefollowingformula:

I It

=

It=short ciricut current for t sec.(Amp)l=short circuit current for one sec.(Amp)t=short circuit duration(sec.)The duration of the short circuit based on these assumptions should be between 0.2 sec.

and5sec.

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 124: NEK606 Offshore & Marine Cables

Technical Information

122 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Conductor area mm²

Current 1 second amperes

Conductor area mm²

Current 1 second amperes

Conductor area mm²

Current 1 second amperes

Conductor area mm²

Current 1 second amperes

1.0 140 10 1400 70 9800 240 336001.5 210 16 2240 95 13300 300 420002.5 350 25 3500 120 16800 400 560004 560 35 4900 150 21000 500 700006 840 50 7000 185 25900 630 88200

Reactance

ThereactanceofacableoperatinginanACsystemdependsonmanyfactors,including,inparticular,theaxialspacingbetweenconductorsandtheproximityandmagneticpropertiesofadjacentsteelwork.Theformerisknownformulticorecable,butmayvaryforsinglecorecables depending upon the spacing between them and their disposition when installed.

Reactance of cables in certain dispositions remote from steelwork is calculable and is shown. The values are for cables with circular conductors.

Thevalueforasector-shapedconductorshouldbetakenas90%ofthecalculatedvalue.Inductionfor2-,3-and4-conductorcablesisgivenbytheformula:

0.2 2 0.25 10lnL ad

6# #= + -a k: D [H/m]a = Axial space between conductors in mm.d = conductor diameter in mm.

Reactancefor2-,3-and4-conductorcablesisgivenbytheformula:

2X fLIr= [Ω]f = frequency in HzL=InductioninH/mI=Conductorlengthinm

Impedance

Inductionfor2-,3-and4-conductorcablesisgivenbytheformula:

Z R X2 23= +^ h [Ω]R=ResistanceatoperatingtempratureinΩX=ReactanceinΩ

Page 125: NEK606 Offshore & Marine Cables

Technical Information

123ADDISONwww.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Core Identification

The identification of insulated conductors (cores) for the 250 V cables Cable element Colour of cores

Pair Black Light blueTriple Black Light blue Brown

Pairs/triples are numbered with numbered tape or by numbers printed directly on the insulated conductors

The identification of insulated conductors (cores) for the 0.6/1 kV cables according to NEK standard

No. of cores Colour of coresSingle core Off-white(grey)Two cores Off-white(grey) Black

Three cores Off-white(grey) Black RedFour cores Off-white(grey) Black Red Blue

above 4 cores black numbers on white baseearthing core yellow/green

The identification of insulated conductors (cores) for the 0.6/1 kV cables according to standard HD 308 S2

Cables with a green/yellow coreNo. of cores Colour of cores*Three cores Green/yellow Blue BrownFour cores** Green/yellow - Brown Black GreyFour cores Green/yellow Blue Brown BlackFive cores Green/yellow Blue Brown Black Grey

** For certain applications only.* In this table an uninsulated concentric conductor, such as a metallic sheath, armour or screen wires, is not regarded as a core. A concentric conductor is identified by its position and, therefore, need not be identified by colour.

Cables without a green/yellow coreNo. of cores Colour of cores*Two cores Blue Brown

Three cores** - Brown Black GreyThree cores Blue Brown BlackFour cores Blue Brown Black GreyFive cores Blue Brown Black Grey Black

** For certain applications only.* In this table an uninsulated concentric conductor, such as a metallic sheath, armour or screen wires, is not regarded as a core. A concentric conductor is identified by its position and, therefore, need not be identified by colour.

The identification of insulated conductors (cores) for the 3.6/6kV, 6/10kV, 8.7/15kV,12/20kV and 18/30kV cables

No. of cores Colour of coresSingle core off-white insulation + black semi conducting layers

Three coresoff-white insulation + black semi conducting layers identified by White-Black-Red threads under

and over the metallic screen on each individual core.earthing core yellow/green

www.caledonian-cables.co.uk www.caledonian-cables.de [email protected]

Page 126: NEK606 Offshore & Marine Cables

Power and Control Cables

124 ADDISON www.addison-cables.com

NEK606 Caledonian Offshore & Marine Cables

www.caledonian-cables.co.uk

Caledonian Offshore & Marine Cables

NEK606 STANDARD

www.caledonian-cables.co.ukwww.addison-cables.ccom

Caledonian

UNITED KINGDOM

Marchants Industrial Centre, Mill Lane, Laughton, Lewes, East Sussex, BN8 6AJ, UKTel: 44 (0) 207 419 5087Fax: 44 (0) 207 831 9489Email: [email protected]

HONG KONG

Unit B 22/F CMA Building, 64-66 Connaught Road Central, Hong KongTel: 852 36527508Fax: 852 35834834Email: [email protected]