  • Introduction

  • 4 © NEC Corporation 2015 NEC Group Internal Use Only4 © NEC Corporation 2017

    Total management of ICT resources

    ▌Provide integrated management for physical server, virtual server, storage and network resource.

    ▌Customer can improve management of IT environment.

    Administrator

    Software/patchdistribution

    Self controlrecovery

    Self scale outHW failuredetection

    Physical serverHetero virtualization

    environment

    VMware ESX Server

    仮想マシン

    業務C

    OS

    仮想マシン

    OS

    業務A

    仮想マシン

    OS

    業務B

    VMware ESX Server

    仮想マシン

    業務C

    OS

    仮想マシン

    OS

    業務A

    仮想マシン

    OS

    業務B

    VMware ESX/Hyper-V/XenServer/KVM

    VM

    App C

    OS

    VM

    OS

    App A

    VM

    OS

    App B

    Network/Storage

    (1)Physical server

    (2)Virtualization/cloud

    (3)Network/Storage

  • 5 © NEC Corporation 2015 NEC Group Internal Use Only5 © NEC Corporation 2017

    Private/Public Cloud

    Revolution of SSC applied to the usage of the enterprise system

    SSC 1.0Enhanced management of blade server and rack server

    SSC 2.0Enhanced integrated management of

    physical and virtual environment

    SSC 3.6Enhanced total ICT management

    function

    Changes in system

    Development starts in 2000 100 system introductions per year Have many oversea sales

    Commonvirtualization infrastructure

    Serverconsolidation

    by virtualization

    Server consolidation by

    blade server

  • Merits of SigmaSystemCenter

    Efficient Building

    Optimal Operation

    Quick Maintenance

  • 7 © NEC Corporation 2015 NEC Group Internal Use Only7 © NEC Corporation 2017

    SigmaSystemCenter support IT system in wide-range

    QuickMaintenance

    EfficientBuilding

    OptimalOperation

    Topology High availability

    Quick provisioning Optimal provisioning

    Reporting Policy-based operation Resource pool

  • 8 © NEC Corporation 2015 NEC Group Internal Use Only8 © NEC Corporation 2017

    SigmaSystemCenter support IT system in wide-range

    QuickMaintenance

    EfficientBuilding

    OptimalOperation

    Topology High availability

    Quick provisioning Optimal provisioning

    Reporting Policy-based operation Resource pool

  • 9 © NEC Corporation 2015 NEC Group Internal Use Only9 © NEC Corporation 2017

    Quick provisioning in physical environment

    By provisioning, SSC can implement switches and storage of configuration.

    It is possible immediately to start a business after provisioning.

    ▌Complicated settings are automated by the provisioning of SSC

    LB settingPatch/app

    installation

    OS

    installationVLAN setting

    Assign

    disk volume

    • Associate the server

    HBA and storage

    volume

    • To distribute the OS image

    • To set the parameters- Computer name- password- IP address

    • Service pack• Application• RPM• Script

    • Add the server to the load balancer group

    • Set VLAN on the switch port to which the server is connected

    LB settingAssign disk volume

    OS installation Patch/app installation

    VLAN setting

    Provisioning

    Because it allows multiple server provisioning at one-click, SSC can built system quickly and without error

    Building efficiency

  • 10 © NEC Corporation 2015 NEC Group Internal Use Only10 © NEC Corporation 2017

    SigmaSystemCenter can manage server and network virtualization

    Based on the model of each business system, administrator can build system quickly. Prevent from miscommunication between server and network administrators

    Network Virtualization(PFS)Server Virtualization Server Virtualization

    VM01 VM02L2SW L2SW

    VTN

    Programmable FlowController

    (1)

    Request to create virtual network

    Request to create

    network and virtual server

    VM1

    VM2

    subnet

    Model of business system

    VMNetwork

    Building efficiency

    (2)

  • 11 © NEC Corporation 2015 NEC Group Internal Use Only11 © NEC Corporation 2017

    The SDN × SSC Solution

    Network Manager

    PFC

    Server Manager

    Send information of VLAN, then check.

    1.Create VTN

    2. Create vBridge

    3. Create vRouter

    1.Create vSwitch

    2. Create Portgoup

    3. Create VM

    4. AssignIP Address

    Hyper-V VMware

    KVM

    Server Manager

    SSC

    1.Create Setting of Logical Network

    2.Execute automatically

    1. It takes timebecause of many manual operation

    Problem

    1. Automatic execution

    Solution

    2. Human resource is necessary of network manager and server manager

    2. Server manager can create Network only using SSC

    Building efficiency

  • 12 © NEC Corporation 2015 NEC Group Internal Use Only12 © NEC Corporation 2017

    Related work: Microsoft SCVMM Integration

    1. Only Hyper-V

    Problem

    2. SCVMM need high SI cost

    1. SSC can manage Hyper-V, VMware, KVM, Xenserver

    Solution

    2. Compared to SCVMM, SSC can easy setup

  • 13 © NEC Corporation 2015 NEC Group Internal Use Only13 © NEC Corporation 2017

    Optimal provisioning in virtual environment

    Automatic selection of the best host and storage device when creating a guest OS

    Building efficiency

    Benefits

    Selects the most suitable host and balances CPU and memory loads

    Selects the most suitable storage device and balances storage consumption

    Description

    ▐ Creates guest OSs on servers to distribute the host and storage device

    loads.

    Server C

    App

    OS

    App

    OS

    Server B

    App

    OS

    App

    OS

    Server A

    App

    OS

    App

    OS

    Storage device Storage device

    Management server

    Selects a host

    Selects a storage device

  • 14 © NEC Corporation 2015 NEC Group Internal Use Only14 © NEC Corporation 2017

    EfficientBuilding

    OptimalOperation

    Quick provisioning Optimal provisioning

    Reporting Policy-based operation Resource pool

    QuickMaintenance

    Topology High availability

    SigmaSystemCenter support IT system in wide-range

  • 15 © NEC Corporation 2015 NEC Group Internal Use Only15 © NEC Corporation 2017

    Merit of sharing system-management standardization (resource pool)-

    By using resource pool, you can utilize unused resources which were not used as individual systems and minimize cost.

    Sales support system

    HQ procurement system

    CPUmemory HDD CPUmemory HDD

    Virtualization

    VM VM VM

    -Hardly see division’s IT resource -Hardly share unused resource

    Sales support HQ procurementsystem

    Resource pool

    With pooling unused resource, realize effective resource usage.

    CPU memory HDD CPU memory HDD

    Use as needed Flexible resource usage

    Surplus Deficit

    IT System Dept.

    Manage whole resourceIT System Dept.

    Silo style (Sub-optimized) Common ICT Infra.(Whole optimized)

    Can not shareHardly see

    whole system & resource

    Infrastructure Management

    Deploy

  • 16 © NEC Corporation 2015 NEC Group Internal Use Only16 © NEC Corporation 2017

    Detect exhaustion of resource pool

    ▌Extend system overall resources systematically as resource pool

    Send E-mail to administrator if the resource pool reaches over threshold.

    Resource Pool Capacity

    Threshold

    Resource poolUsage

    Over Threshold

    Send e-mail

    Add resource

    Check exhausted resource

    Keep safety line

    Extend resource pool

    System Admin

  • 17 © NEC Corporation 2015 NEC Group Internal Use Only17 © NEC Corporation 2017

    Access control to resource pool

    SSC can limit the resource access between tenant by a roll management function.

    ServersStorage

    devices

    Network

    devicesImages

    Tenant

    administratorSub resource pool

    App

    OS

    Tenant

    administrator IP/VLAN pool Image library

    Tenant A Users

    Use

    Configuration

    Maintenance and

    troubleshooting by

    users

    The VM and

    resources of

    other tenants

    cannot be

    accessed

    System

    administrator

    Resource

    pool

    Tenant creation/

    creation of user for tenant

    administrator/

    Allocation of sub resource pool

    Resource pool

    creation/extraction

    from the sub

    resource pool

    App

    OS

    App

    OS

    Sub resource pool

    App

    OS

    IP/VLAN pool Image library

    Tenant B Users

    Use

    Configuration

    Maintenance and

    troubleshooting by

    users

    App

    OS

    App

    OS

    Service portal Service portal

    Resource

    reservation

    and VM

    creation

    VM power

    control

  • 18 © NEC Corporation 2015 NEC Group Internal Use Only18 © NEC Corporation 2017

    Assessment report

    SSC outputs the report which shows resource information to manage the virtual environment. It’s possible to modify chart and table data of report.

    grasp quickly virtual environment status and easily make report to supervisor.

    VM VM VM

    Target Machine

    VM VM VM

    Management Server PC

    .xls

    ◆ Contents of report• List of VM and VMS• Ranking of resource usage• Status of resource usage (overview)• Status of resource usage (timeseries)• Analysis of VM spec

    2. Select necessary report

    Gather data

    1. Convert data to csv format

    VMS

  • 19 © NEC Corporation 2015 NEC Group Internal Use Only19 © NEC Corporation 2017

    Automation using policies

    Solving problems in system operations through the creation of policies

    Without SSC

    Memory

    failure

    App

    OS

    App

    OS

    It looks like there’s a memory

    failure. Should I move the

    guest OS? Or perform a fall

    back operation?

    Using SSC

    Live migration or failover

    App

    OS

    App

    OS

    Operator

    Memory

    failure

    App

    OS

    App

    OS

    Live migration or failover

    App

    OS

    App

    OS

    SSC

    Error

    Error

    Instructs the movement of the guest OS Instructs the movement of the guest OS

    ------

    ------

    Policy

    Moves guest OSs automatically by

    following policies

    Server A Server B Server BServer A

    RisksBenefits

    The systems may be interrupted due

    to the operational and checking errors

    by the operator

    Potential delays due to delayed resolutionOperational and other mistakes that result

    from human error are eliminated

    Can run automatically at night

    vCenter Server/

    Hyper-V Manager

    vCenter Server/

    Hyper-V Manager

    Failure event

  • 20 © NEC Corporation 2015 NEC Group Internal Use Only20 © NEC Corporation 2017

    Resource Optimization in virtual environment 2 Power Consumption Optimization

    Virtual Machines are relocated dynamically according to system load level.Idle servers can be powered off if desired to reduce power consumption.

    CPU Usage Rate

    Appropriate

    Load Level

    on on on offoffon on on on on

    PowerOFF

    Appropriate

    Load Level

    Load monitoring

    Relocating VM to keep appropriateload level.

    Then, extra server are powered off.

  • 21 © NEC Corporation 2015 NEC Group Internal Use Only21 © NEC Corporation 2017

    Resource Optimization in virtual environment 1Optimized Placement of Virtual Machines (1/2)

    NEC SigmaSystemCenter monitors the load status of each server.Live migration relocates virtual machines and equalizes entire load when high load detected.

    VMware ESX/XenServer VMware ESX/XenServer

    Virtual Machine

    Job C

    OSVirtual Machine

    OS

    Job B

    Virtual Machine

    OS

    Job A

    Virtual Machine

    OS

    Job B

    High Load Detected

    Storage

    Relocates virtual machines to equalizethe load of ESXs/XenServers

    with live migration

    Virtual Machine

    OS

    Job D

  • 22 © NEC Corporation 2015 NEC Group Internal Use Only22 © NEC Corporation 2017

    Resource Optimization in virtual environment 1 Optimized Placement of Virtual Machines (2/2)

    Enable load equalization and power saving operation by setting up appropriate load threshold in optimization engine.

    The Optimization Engine – Threshold set up UIFig.1.Load equalizationby allocating VM tolow load server.

    Fig.2.As all servers are loaded beyond a threshold, NEC SigmaSystemCenter will build up a new ESX Server to equalize server load.

  • 23 © NEC Corporation 2015 NEC Group Internal Use Only23 © NEC Corporation 2017

    Resource Optimization in virtual environment 3 Automated Scale-out

    Turns backup server power on and equalizes resources as needed because of high load detection.In case of VMware environment, automated provisioning of new ESX servers from bare-metal state enables on-demand scale-out.

    Appropriate Load

    on on on offoff on on on on on

    Power off

    Appropriate Load

    Achieves Load Dispersion of ServerResources

    High Load

    Power on

    Standby(Not Operating)

    Operating ResourcesEqualized

    (1) Load Monitoring(2) Optimal

    Location Calculation(3) Power On (4) Equalization

    High Load

  • 24 © NEC Corporation 2015 NEC Group Internal Use Only24 © NEC Corporation 2017

    SigmaSystemCenter support IT system in wide-range

    QuickMaintenance

    Topology High availability

    EfficientBuilding

    Quick provisioning Optimal provisioning

    OptimalOperation

    Reporting Policy-based operation Resource pool

  • 25 © NEC Corporation 2015 NEC Group Internal Use Only25 © NEC Corporation 2017

    High availability

    NEC SigmaSystemCenter can detect and recover from failures of virtual machines and virtualization platform.Avoid downtime with predictive failure detection and pre-emptive live migration.

    Administrator

    Reports

    VMware ESX/XenServerVMware ESX/XenServer Storage

    Virtual Machine

    OS

    Job A

    Virtual Machine

    Job C

    OS

    Virtual Machine

    OS

    Job A

    Virtual Machine

    OS

    Job B

    Virtual Machine

    OS

    Job A

    Response 2 :Reboots and recovers virtual machines

    when vMotion unavailable

    Detects

    Abnormality

    Response 1 : Pre-emptive Migration with vMotion

  • 26 © NEC Corporation 2015 NEC Group Internal Use Only26 © NEC Corporation 2017

    Totally management of a failure and performanceof the system infrastructure.

    ICT resource

    Hypervisor/VM

    AP

    Server

    AP AP AP

    OS

    Windows Linux

    Application monitoring tool

    Windows

    Storage

    Linux

    ▐ Collect a variety of monitoring information in server, storage, network,

    hypervisor and OS.

    vCenter Server (ESX)

    Hyper-V

    KVM

    XenServer

    * If you want to integrate the monitoring of storage and network equipment, SigmaSystemCenter needs to collaborate with MasterScope Network Manager and iStorage Manager.

    Network

  • 27 © NEC Corporation 2015 NEC Group Internal Use Only27 © NEC Corporation 2017

    Quickly detect business impact scope of HW failure.

    SSC can display a warning in HW fault symptom and its effects range

    LUN

    Storage Pool

    LUN

    DataStore

    DataStore

    VM VM VM

    ESX

    F

    F

    F

    F

    F

    F

    DBWebAP

    FEvent History

    Topology View

    LUN

    5. see detail of storage information and check topology view

    2. Alert from SSC

    3. Check alert

    4. Link to the failed equipment details

    Visualization ofbusiness impact

    6. Check the business impact by topology view

    which can display

    information from HW status to virtual status.

    Administrator

    F Failure

    1. Redundancy

    lost

  • Conclusion

  • 29 © NEC Corporation 2015 NEC Group Internal Use Only29 © NEC Corporation 2017

    Infrastructure management of SigmaSystemCenter

    Total management of physical/virtual server,

    storage and network.

    Optimal utilization of infrastructure resources

    by autonomy and automation.

    Visualize virtual environment and flexibly control.