s u s t a i n a b I l I t y EarthWise Systems National Building Commissioning Conference April 22, 2008 Kenyon Holmes Senior Account Executive Southern California Trane

Transcript of National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules...

Page 1: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

EarthWise™ Systems National Building Commissioning Conference April 22, 2008

Kenyon HolmesSenior Account Executive

Southern California Trane

Page 2: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

EarthWise™ Systems?

EmissionsEmissions

EnergyEnergy EfficiencyEfficiency

Page 3: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Clinton Climate Initiative

“Goal: to Reduce Carbon Emissions and Increase Efficiency In Largest Cities Across the World”

$5 Billion Dollars - 40 major Cities

Page 4: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Buildings use 39% of the Primary Energy Consumed in the United States

Page 5: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

U.S. Buildings = 9.8 percent of Total Global CO² Emissions

Page 6: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Number of EarthWise SystemsChilled water/VAV systems

Low flow, low temperaturehigh efficiency systems• What do they do?

• How do they do it?

• Why use them?

Page 7: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Low Flow, Low Temperature, High Efficiency Systems

+/+/--$$air handlers

+/+/--$$

+/+/--$$controls

chillers+/+/--$$piping

~/~/––$$

ductwork

~/~/––$$

Page 8: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

How?

Temperature differential

Supply temperature Flow rates Fans

Ductwork

Pump

Piping

Page 9: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Why Use LLH Systems?Good for business: Offers the potential to lower first cost and/orand/or operating cost whileenhancing comfort, IAQ, and acousticsEnvironmentally responsible: Reduced utility generated greenhouse gas emissions and uses less natural resourcesIdeal for use in health care, institutional, governmental, office building, education, and other markets where VAV systems are used

Page 10: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Chilled Water/VAV Systems

% o

f HVA

C e

nerg

y co

nsum

ptio

n

83%93%70%83%89%80%

Trane EarthWise™ System

AtlantaMinneapolisLos AngelesDenverPhiladelphiaPortland

100%100%100%100%100%100%

Conventional System

100

95

90

85

80

75

70

65

60

LEED®

EAc1

Page 11: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

ChillerCooling towerWater pumps

Chilled Water/VAV Systems

1970’s

73%

9%

18%

2007

51%

31%

17%

Page 12: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

8.0

ASHRAE Standard 90.1

Chill

er e

ffic

iency

, CO

P

6.0

4.0

2.0

0.0“best”

available

Centrifugal >600 tonsScrew 150-300 tonsScroll <100 tonsReciprocating <150 tons

1977 1980 1989 1999

History of Chiller Performance

Page 13: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

chilled water plant design...

Old “rules of thumb”44°F chilled water supply

10°F delta T across the evaporator -that’s at 2.4 GPM/ton

10°F delta T across the condenser -that’s at 3.0 GPM/ton

Page 14: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

chilled water plant design...

New “rules of thumb”41°F chilled water supply

16°F delta T across the evaporator -that’s at 1.5 GPM/ton

15°F delta T across the condenser -that’s at 2.0 GPM/ton

Potentially downsized the cooling tower

Page 15: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Yeah, but….

Cold downdrafts

Condensation

Page 16: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

three keys to… Eliminating Cold Downdrafts

Parallel fan-powered units on the perimeter…

Cooling-only boxes on the interior…

Both with linear slot aspirating diffusers...

Page 17: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Linear Slot Diffuser vs. Typical

Page 18: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

What about Condensation?

Cold surfaces must be kept inside the humidity controlled envelope

Night set back and morning pull down controlled off of “interior dew point”

Positive building pressure is critical for “no” condensation and IAQ

Install a vapor barrier with reasonable construction

Design the “P” traps and pitch the condensate drains correctly LEED - WEc1.2

Page 19: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Optimized Controls

Page 20: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Fan Pressure Optimization

Page 21: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Fan Pressure Optimization

Page 22: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Pump Pressure Optimization

Page 23: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.
Page 24: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.
Page 25: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Wireless zone sensors

Auto-commissioning

Auto-calibration

next generation VAV box control Capabilities That Are Available Today!!

Page 26: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Reduce installed costLower riskAbility to handle churn

Wireless Zone Sensors

Page 27: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Auto-Commissioning

Do you remember? Retro-commissioning…Why not automatically?

Page 28: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Auto-Calibration

Automatically calibrates the flow transducer, air valve, and hot-water valve• Calibration occurs on the transition to unoccupied

The calibration can also be scheduled• Necessary for 24/7 applications

Page 29: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Graphical Interface Floor Plan

Page 30: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Floor Plan

Page 31: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Chiller-Water VAV Systems

Page 32: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Chiller-Water VAV Systems

Page 33: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Yeah but, show me the money!

Page 34: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

New Construction Project

J. D. Edwards, Denver, CO

Owner occupied office campus

Each building 190,000 sq. ft

Page 35: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Owner Focus: Reliability and Cost

Job specifics:

2 chillers at 250 tons each

7 size 40 AHUs, one per floor

240 fan-powered VAV boxes

Page 36: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Waterside Installed Cost

labor

pipe and fitting

valves/special

insulation

pumps

chillers

cooling towers

electrical

total

($ 5,011)

($33,466)

($14,529)

($ 1,150)

($ 1,428)

$ 2,760*

($ 1,280)

($ 460)

($57,324) or

$.30/sq. ft.

$31,649

$88,177

$36,977

$ 7,038

$ 4,519

$26,639

$54,711

$22,448

$ 5,888

$ 3,091

Difference10°F ΔT18°F ΔTComponent

Page 37: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Airside Installed Cost

labor

AHUs

VAVs

sheet metal

sub total

electrical

total

($6,759)

($28,176)

($6,868)

($16,362)

($58,164)

($5,950)

($64,114) or

$.34/sq. ft.

$174,715

$208,520

$165,242

$ 86,456

$634,932

$167,956

$180,343

$158,374

$ 70,095

$576,768

Difference55°F cost45°F costItem

Page 38: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Total System Installed Cost

airside

wetside

subtotals

electrical (airside)

electrical (wetside)

total

($ 58,164)

($ 56,864)

($115,028

($ 5,950)

($ 460)

($121,438) or

.64/sq. ft.

$634,932

$168,361

$803,293

$576,768

$111,497

$688,265

Difference55°F cost45°F costItem

Page 39: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

Annual Energy Savings JD Edwards/First Cost Focus

supply fans

chillers

FVAV boxes

pumps

reheat with reset

total

6.8

(0.5)

(1.2)

0.7

(2.2)

$11,000

(890)

(1,940)

1,170

(3,700)

¢ per ft2DollarsComponent

3.6 or 4%

Page 40: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y

What Did We Say Regarding Low Flow, Low Temperature, High Efficiency Systems?

What they do?

How they do it?

Why use them?Emissions

Energy Efficiency

Page 41: National Building Commissioning Conference - bcxa.org · chilled water plant design... New “rules of thumb ... Potentially downsized the cooling tower. ... cooling towers. electrical.

s u s t a i n a b I l I t y