2
Applications Simple VUF separators have been utilized successfully as: Fuel gas scrubbers Slug catchers Surge vessels Gas vent vessels Small-capacity production separators Test separators Alternate designs should be considered for vessels more than 42” in diameter at low pressures and more than 30” in diameter at high pressures. Data Sheet | TC9814-019 NATCO Vertical Upflow (VUF) Separator VUF separators for cost-effective gas/liquid separation The simple design of Cameron’s NATCO ® VUF separator makes it one of the most commonly used gas scrubbers in the marketplace. It is an economical design for low pressures and/or low flow rates. This vertically oriented vessel features a side inlet and a gas outlet normally located on the top of the separator. Alternate gas outlet designs are available to reduce overall vessel height. How It Works VUF separators normally provide four main functions – inlet momentum control, vapor demisting, liquid retention and liquid outlet control. Inlet momentum typically is controlled with a bi-directional inlet diverter that also provides bulk gas/liquid separation. Vapor demisting normally is achieved with wire mesh. If heavy or waxy crudes are present, wire mesh can be eliminated or replaced with serpentine vanes. Liquid retention is provided in the bottom section of the separator. For three-phase designs, oil and water separate in this section. Sizing of this section often is based on liquid retention time. Liquid outlet control also is provided in the bottom section of the separator. Vortex breakers and baffles prevent the re-entrainment of distinct phases. VUF separator VUF Separator PROCESS & COMPRESSION SYSTEMS GAS

Transcript of NATCO Vertical Upflow (VUF)...

Page 1: NATCO Vertical Upflow (VUF) Separatorfulfillment.directedje.com/DirectResources/DigitalDocuments/5... · separator. For three-phase designs, oil and water separate in this section.

Applications

Simple VUF separators have been utilized successfully as:

• Fuel gas scrubbers

• Slug catchers

• Surge vessels

• Gas vent vessels

• Small-capacity production separators

• Test separators

Alternate designs should be considered for vessels more

than 42” in diameter at low pressures and more than 30”

in diameter at high pressures.

Data Sheet | TC9814-019

NATCO Vertical Upflow (VUF) SeparatorVUF separators for cost-effective gas/liquid separation

The simple design of Cameron’s NATCO® VUF separator

makes it one of the most commonly used gas scrubbers

in the marketplace. It is an economical design for low

pressures and/or low flow rates. This vertically oriented

vessel features a side inlet and a gas outlet normally

located on the top of the separator. Alternate gas outlet

designs are available to reduce overall vessel height.

HowItWorks

VUF separators normally provide four main functions – inlet

momentum control, vapor demisting, liquid retention and

liquid outlet control.

Inlet momentum typically is controlled with a bi-directional

inlet diverter that also provides bulk gas/liquid separation.

Vapor demisting normally is achieved with wire mesh.

If heavy or waxy crudes are present, wire mesh can be

eliminated or replaced with serpentine vanes.

Liquid retention is provided in the bottom section of the

separator. For three-phase designs, oil and water separate

in this section. Sizing of this section often is based on liquid

retention time.

Liquid outlet control also is provided in the bottom section

of the separator. Vortex breakers and baffles prevent the

re-entrainment of distinct phases.

VUF separator

VUF Separator

PROCESS&COMPRESSIONSYSTEMS

G A S

Page 2: NATCO Vertical Upflow (VUF) Separatorfulfillment.directedje.com/DirectResources/DigitalDocuments/5... · separator. For three-phase designs, oil and water separate in this section.

© 2012 Cameron | NATCO is a registered trademark of Cameron | 2/12 TC9814-019

Performance

Since the primary function of most VUF separators is to remove small amounts

of liquids and solids from the vapor stream, performance is based on the overall

percentage of droplet removal.

For designs using wire mesh as a demisting device, removal of 99% of 5 µ droplets

and larger can be expected.

For alternate designs using serpentine vanes, removal of 98% of 10 µ droplets and

larger can be expected.

VUF Separators with Wire Mesh Demister

PROCESS&COMPRESSIONSYSTEMS

LOCATIONS

United States of America

11210 Equity Dr., Suite 100

Houston, TX 77041

USA

Tel +713.849.7500

United Kingdom

Cameron House

61-73 Staines Road West

Sunbury-on-Thames

Middlesex TW16 7AH

England, UK

Tel +44.1932.732000

Singapore

2 Gul Circle (Gate 2)

Jurong, Singapore 629560

Tel +65.6861.3355

OTHERLOCATIONS

Abu Dhabi

Australia

Brazil

Calgary

Colombia

France

Japan

Malaysia

Mexico

Russia

Saudi Arabia

www.c-a-m.com