Nader MCB

24
NDM1 Series NDB2 Series Shanghai Liangxin Electrical CO.,LTD Address: No. 668 Heng An Road, Pu Dong New District, Shanghai Post code: 200137 Tel: 86-21-50412789 Fax: 86-21-50410355 E-mail: [email protected] As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. Be printed on ecological paper. 2010 - Liangxin Electrical - All rights reserved Miniature Circuit Breaker

description

hgjk

Transcript of Nader MCB

  • NDM1 SeriesNDB2 Series

    Shanghai Liangxin Electrical CO.,LTDAddress: No. 668 Heng An Road, Pu Dong New District, Shanghai Post code: 200137Tel: 86-21-50412789Fax: 86-21-50410355E-mail: [email protected]

    As standards, specifications and designs changefrom time to time, please ask for confirmationof the information given in this publication.

    Be printed on ecological paper.

    2010

    - L

    iang

    xin

    Elec

    tric

    al -

    All

    righ

    ts r

    eser

    ved

    Miniature Circuit Breaker

  • NDM1-63 Series Miniature Circuit BreakerNDM1-125 Series Miniature Circuit BreakerNDM1L Series Residual Current ModularNDM1LG Series Over Voltage Residual Current ModularNDB1 Series Miniature Circuit Breaker (1P+N)NDB1L Series Residual Current Circuit Breaker With Overload ProtectionNDB1LG Series Residual Current Circuit Breaker With Overload/Overvoltage ProtectionNDB2-63 Series Miniature Circuit Breaker NDB2T-63 Series Miniature Circuit Breaker NDB2-63K Series Miniature Circuit Breaker (1P+N)NDB2Z-63 Series DC Miniature Circuit Breaker NDB2LE Series Residual Current ModularNDG1 Series Disconnect Switch Tripping CurveTemperature DeratingNDA1 Series Modular SocketNDH1 Series BusbarNDH2 Series Busbar

    030609121517192124272932363840414345

    NDM1 SeriesNDB2 Series

    Leading Low-voltage Electrical Component Manufacturer

    Miniature Circuit Breaker

  • NDM1-63 Series Miniature Circuit Breaker

    ND M 1 63

    03 04

    M Miniature Circuit Breaker

    NDM1-63

    1

    63B, C, D

    1, 2, 3, 4, 5, 6, 10, 16, 20, 25, 32, 40, 50, 63

    1, 2, 3, 4

    Model and Implication

    IEC 60898-1, GB 10963.1;

    TV, CE and CCC.

    Application

    Working Condition

    DimensionCurve B: Non-inductive or micro-inductive loadsCurve C: Usual inductive loads

    Curve D: Highly inductive loads

    Overload and short circuit protection

    Ambient temperature: -35+70

    Air humidity: 95%

    Altitude: 2000m

    Pollution degree:

    No significant shock or vibration

    Wiring Capacity

    25mm2

    Specifications

    Rated working voltage: AC230/400V, DC60V

    Rated working current: 1A - 63A

    Mechanical life: 10000 times

    Tripping characteristic: B: 3-5In; C: 5-10In; D: 10-14In

    Breaking capacity:

    Rated current(A) Voltage(V) Breaking capacity(kA)

    BC: 1-40 AC230/400 6

    5063 AC230/400 4.5

    D : 1-40 AC230/400 4.5Product Features

    Modularized

    Screw clamp, shock-proof wiring terminals

    Numerous accessories available

    Standard 35mm Din Rail mounting

    RoHS complied

    Standards and Certificates

    7

    18 26.

    5

    18max

    36max

    54max

    72max

    1P

    2P3P

    4P

    5.5

    45.5

    80.5

    max

    60

    45

    72.5max

    Brand code

    Product code

    Design code

    Frame rating (A)

    Instantaneous tripping characteristic

    Rated current (A)

    Number of poles

    No. Implication

  • 05 06

    1P

    1

    2

    Number of PolesRated

    Current(A)

    1234561016202532405063123456101620253240506312345610162025324050631234561016202532405063

    2P

    1 3

    2 4

    Part No.

    NDM1-63 1/1NDM1-63 2/1NDM1-63 3/1NDM1-63 4/1NDM1-63 5/1NDM1-63 6/1NDM1-63 10/1NDM1-63 16/1NDM1-63 20/1NDM1-63 25/1NDM1-63 32/1NDM1-63 40/1NDM1-63 50/1NDM1-63 63/1NDM1-63 1/2NDM1-63 2/2NDM1-63 3/2NDM1-63 4/2NDM1-63 5/2NDM1-63 6/2NDM1-63 10/2NDM1-63 16/2NDM1-63 20/2NDM1-63 25/2NDM1-63 32/2NDM1-63 40/2NDM1-63 50/2NDM1-63 63/2NDM1-63 1/3NDM1-63 2/3NDM1-63 3/3NDM1-63 4/3NDM1-63 5/3NDM1-63 6/3NDM1-63 10/3NDM1-63 16/3NDM1-63 20/3NDM1-63 25/3NDM1-63 32/3NDM1-63 40/3NDM1-63 50/3NDM1-63 63/3NDM1-63 1/4NDM1-63 2/4NDM1-63 3/4NDM1-63 4/4NDM1-63 5/4NDM1-63 6/4NDM1-63 10/4NDM1-63 16/4NDM1-63 20/4NDM1-63 25/4NDM1-63 32/4NDM1-63 40/4NDM1-63 50/4NDM1-63 63/4

    Curve

    B, C, D

    B, C

    B, C, D

    B, C

    B, C, D

    B, C

    B, C, D

    B, C

    Width(mm)

    18

    36

    54

    72

    2 4 6

    1 3

    3P

    5

    1 3 5

    4P

    2

    4 6 8

    7

    NDM1-125 Series Miniature Circuit Breaker

    UL1077, IEC 60947-2, GB 14048.2;

    UL, TV, CE, CCC.

    Application

    Curve C: Usual inductive loads

    Curve D: Highly inductive loads

    Overload and short circuit protection

    Only Curve C available for 125A

    Standards and Certificates

    Working Condition

    Ambient temperature: -35+70

    Air humidity: 95%

    Altitude: 2000m

    Pollution degree:

    No significant shock or vibration

    Specifications

    Rated working voltage: AC230/400V, DC60V

    Rated working current: 50A - 125A

    Mechanical life: 10000 times

    Rated impulse withstand voltage: 6kV

    Tripping characteristic

    C: 8In (20%) D: 12In (20%)

    Breaking capacity:

    Product Features

    Modularized

    Screw clamp, shock-proof wiring terminals

    Numerous accessories available

    Standard 35mm Din Rail mounting

    RoHS complied

    Wiring capacity

    50mm2

    ND M 1

    M Miniature Circuit Breaker

    NDM1-125

    1

    125

    C, D

    50, 63, 80, 100, 125

    1, 2, 3, 4

    Model and Implication

    Brand code

    Product code

    Design code

    Frame rating (A)

    Instantaneous tripping characteristic

    Rated current (A)

    Number of poles

    1257

    50~125

    50~125

    Rated current(A)

    1P

    2~4P

    Pole number

    AC 230

    AC230/400

    Voltage (V)

    10

    10

    Breakingcapacity(kA)

    No. Implication

  • 07 08

    Number of Poles Width(mm)

    27

    54

    81

    108

    Curve

    C, D

    C

    C, D

    C

    C, D

    C

    C, D

    C

    Rated Current(A)

    50

    63

    80

    100

    125

    50

    63

    80

    100

    125

    50

    63

    80

    100

    125

    50

    63

    80

    100

    125

    Part No.

    NDM1-125 50/1

    NDM1-125 63/1

    NDM1-125 80/1

    NDM1-125 100/1

    NDM1-125 125/1

    NDM1-125 50/2

    NDM1-125 63/2

    NDM1-125 80/2

    NDM1-125 100/2

    NDM1-125 125/2

    NDM1-125 50/3

    NDM1-125 63/3

    NDM1-125 80/3

    NDM1-125 100/3

    NDM1-125 125/3

    NDM1-125 50/4

    NDM1-125 63/4

    NDM1-125 80/4

    NDM1-125 100/4

    NDM1-125 125/4

    DC Application

    Wiring Schematics

    Dimension

    MCB rated current decided by the power of DC control circuit

    According to DC rated voltage, there are several kinds of MCB cascade below

    Revised feeding of line power is permitted

    The estimated short circuit current can not exceed rated service short-circuit breaking capacity

    1P

    1

    2

    2P

    1 3

    2 4

    Specification Rated Current (A)

    3P

    1 3 5

    2 4 6

    4P

    1 3 5 7

    2 4 6 8

    DC60V One pole

    DC125V Two poles

    DC250V Four poles

    DC rated service short-circuit breaking capacity (kA)

    250V

    NDM1-63

    NDM1-125

    1A~63A

    50A~125A

    60V

    10 (1P)

    20 (1P)

    125V

    20 (2P)

    20 (2P)

    50 (4P)

    15 (4P)

    NDM1-63

    NDM1-125

    1P

    NDM1-63

    NDM1-125

    2P

    NDM1-63

    NDM1-125

    4P

    + +- 60V - 125V

    +- 250V

    Load Load Load

    108max

    27max54max

    81max

    1P

    16.5

    26.5

    5.549.5

    60

    45

    85m

    ax

    74.5max2P3P4P

  • Brand code

    Product code

    Design code

    Residual current protection

    Frame rating (A)

    Number of poles

    Rated residual operating current (mA)

    NDM1L Series Residual Current Modular

    ND M 1 L

    09 10

    M Miniature Circuit Breaker

    NDM1L

    1

    L

    32, 50, 100

    1PN, 2P, 3P, 3PN, 4P

    30, 100

    Model and Implication

    NDM1L-32, NDM1L-50: IEC 61009-1, GB 16917.1; CCC.

    NDM1L-100: IEC60947-2, GB14048.2; CCC.

    Application

    Working Condition

    NDM1L-32 (50) Residual Current Modular

    Dimension

    Specifications

    Clip onto the right side of NDM1 series MCB

    Protection against earth leakage faults

    Ambient temperature: -5 ~+40

    Air humidity: 95%

    Altitude: 2000m

    Pollution degree:

    No significant shock or vibration

    Wiring Capacity

    NDM1L-32: 50mm2

    NDM1L-50: 50mm2

    NDM1L-100: 50mm2

    Rated working voltage: AC230/400V (1PN2P)

    AC400V (3P3PN4P)

    Rated residual operating current: 30mA, 100mA

    Release type: AC, electronic

    Standards and Certificates

    65 7

    NDM1L-32, 50 NDM1L-100

    Number of Poles Part No.

    NDM1L-32/1PN

    NDM1L-50/1PN

    NDM1L-32/2

    NDM1L-50/2

    NDM1L-32/3

    NDM1L-50/3

    NDM1L-32/3PN

    NDM1L-50/3PN

    NDM1L-32/4

    NDM1L-50/4

    Frame Rating(A)

    32

    50

    32

    50

    32

    50

    32

    50

    32

    50

    Rated ResidualOperating Current (mA)

    30

    30

    30

    30

    30

    30

    30

    30

    30

    30

    Width (mm)

    27

    37

    27

    37

    36

    51

    45

    64

    45

    64

    45

    4060

    5.5

    69.5max

    94m

    ax

    L

    1PN2 N

    N

    1

    3P2 4 6

    1 3 5

    3PN1 3 5

    1 3 5 N

    4P1 3 5 7

    2 4 5 8

    2P1 3

    2 4

    No. Implication

  • Brand code

    Product code

    Design code

    Residual current protection

    Over voltage protection

    Frame rating (A)

    Number of poles

    Rated residual operating current (mA)

    11 12

    Release should be released before MCB dielectric test.

    NDM1L-100 Series Residual Current Modular

    Number of Poles Part No.

    NDM1L-100/1PN

    NDM1L-100/2

    NDM1L-100/3

    NDM1L-100/3PN

    NDM1L-100/4

    100

    100

    100

    100

    100

    Frame Rating(A)

    30, 100

    30, 100

    30, 100

    30, 100

    30, 100

    Rated ResidualOperating Current (mA)

    54

    54

    73

    90

    90

    Width(mm)

    1PN

    3P

    3PN

    4P

    2P1 3

    2 4

    NDM1LG Series Over Voltage Residual Modular

    ND M 1 L G

    8

    M Miniature Circuit Breaker

    NDM1LG

    1

    LG

    32, 50

    1PN, 2P

    30, 100

    Model and Implication

    IEC 61009-1, GB 16917.1; CCC

    Application

    Clip onto the right side of NDM1 series MCB

    Protection against earth leakage faults and overload

    Standards and Certificates

    7 8

    Working Condition Dimension

    Specifications

    Ambient temperature: -5 ~+40

    Air humidity: 95%

    Altitude: 2000m

    Pollution degree:

    No significant shock or vibration

    Wiring Capacity

    NDM1L-32: 10mm2

    NDM1L-50: 25mm2

    Rated working voltage: AC230/400V(1PN, 2P)

    Over voltage limits: AC280V5%

    Release type: AC, electronic

    NDM1LG-32, 50

    L

    94m

    ax

    69.5max

    5.5

    6040

    45

    Rated residual operating current can be customized upon request, such as 6mA, 10mA, 100mA, etc.

    Release should be used and ordered together with Nader MCB.

    No. Implication

  • 13 14

    Release should be released before MCB dielectric test

    NDM1LG-32 (50) Series Over Voltage Residual Current Modular

    Match Principle

    Number of Poles Part No.

    NDM1LG-32/1PN

    NDM1LG-50/1PN

    NDM1LG-32/2

    NDM1LG-50/2

    Frame Rating(A)

    32

    50

    32

    50

    Rated ResidualOperating Current (mA)

    30

    30

    30

    30

    Width (mm)

    27

    37

    27

    37

    1PN2 N

    N

    1

    2P1 3

    2 4

    OF Auxiliary Switch

    NDM1 Series MCB

    NDM1-63

    NDM1-125

    1P

    2P

    3P

    4P

    NDM1L Series Residual Current Modular

    1PN

    2P

    3P, 3PN

    4P

    NDM1L (G)-32 (1A-32A)

    NDM1L (G)-50 (40A, 50A)

    NDM1L-100 (50A, 63A, 80A, 100A)

    Frame rating

    Number of poles

    ApplicationLinked to the left side of NDM1 seires MCB, to indicate the OPEN or CLOSED status of the associated breaker

    Specifications

    Current

    AC

    DC

    DC

    Voltage

    230V

    24V

    125V

    Current

    6A

    6A

    1A

    AC

    DC

    DC

    Voltage

    400V

    48V

    250V

    3A

    2A

    0.4A

    SD Alarm Switch

    Wiring Capacity

    Application Linked to the left side of NDM1 series MCB, to indicate the tripping status of the associated breaker

    Specifications

    AC

    DC

    DC

    Voltage

    230V

    24V

    125V

    Current

    6A

    6A

    1A

    AC

    DC

    DC

    Voltage

    400V

    48V

    250V

    Current

    3A

    2A

    0.4A

    Single line: 2.5mm2 Double line: 1.5mm2

    IEC 60947-5, GB 14048.5;TV, CE, CCC.

    Standards and Certificates

    11

    12 14

    91

    92 94

    Rated residual operating current can be customized upon request, such as 6mA, 10mA, 100mA, etc.

    Release should be used and ordered together with Nader MCB.

    Width (mm): 9Notes:After clipping on to NDM1 series MCB,Point 11 and 14 are connected when circuit is closed;Point 11 and 12 are connected when circuit is open.May be used in conjunction with a SD alarm switch or another OF auxiliary switch.

    Width (mm): 9

    Notes:After clipping on to NDM1 series MCB,Point 91 and 92 are connected when circuit is closed;Point 91 and 94 are connected when the breaker trips due to fault;Point 91 and 92 are connected when the breaker trips by manual operation. Meanwhile, point 91 and 94 are disconnected.May be used in conjunction with a OF auxiliary switch or another SD alarm switch.

    MX+OF Shunt ReleaseApplicationLinked to the right side of NDM1A series MCB.

    Remote control

    Specifications

    Control voltage AC 230V/400V DC 24V/48V

    Width (mm): 18

    Active transfer contact

    Note: At DC24V, above design of shunt control circuit is recommended

    ZJ: DC24V intermediate relay

    N or -

    MCB closedMCB open

    L or +

    C2C1

    14

    12

    SB

    L1 L2 ZJ

    DC24VA1 A2

    Power input

    ZJ

    MX+OF K

  • 16

    Brand code

    Product code

    Design code

    Frame rating (A)

    Instantaneous tripping characteristic

    Rated current (A)

    NDB1 Series Miniature Circuit Breaker (1P+N)

    ND B C1 32

    15

    B Miniature Circuit Breaker

    NDB1-32

    1

    32

    C

    6, 10, 16, 20, 25, 32

    Model and Implication

    IEC 60898-1, GB 10963.1; CCC.

    Application

    Working Condition

    Dimension

    Specifications

    TT/TN-S grounding system

    Phase and neutral protection against short circuit and overload

    Ambient temperature: -35+70

    Air humidity: 95%

    Altitude: 2000m

    Pollution degree:

    No significant shock or vibration Wiring Capacity

    10mm2

    Product Features

    Phase and neutral are both switched when circuit opens or trips because of failure

    Phase connected early and disconnected late

    Screw clamp, shock-proof wiring terminals

    Standard 35mm Din Rail mounting

    RoHS complied.

    Rated working voltage: AC230V

    Mechanical life: 10000 times

    Tripping characteristic: C: 5-10In

    Breaking capacity: 4.5kA

    Standards and Certificates

    Number of Poles Part No.

    NDB1-32

    NDB1-32

    NDB1-32

    NDB1-32

    NDB1-32

    NDB1-32

    6

    10

    16

    20

    25

    32

    18

    Width (mm)

    C

    Curve

    6

    10

    16

    20

    25

    32

    Rated Current (A)

    1P+N

    6040

    80m

    ax

    5.5

    45

    70.5max

    18max

    No. Implication

  • 18

    Brand code

    Product code

    Design code

    Residual current protection

    Frame rating

    Instantaneous tripping characteristic

    Rated current (A)

    NDB1L Series Residual Current Circuit Breaker with Overload Protection

    ND B C1 L 32

    17

    Model and Implication

    UL1053, IEC61009-1, GB16917.1;

    UL1053 (for NDB1L C10 30mA), TV, CE, CCC.

    Application

    Working Condition

    Dimension

    Specifications

    TT/TN-S grounding system

    Phase and neutral protection against short circuit, overload and earth leakage

    Ambient temperature: -5+40

    Air humidity: 95%

    Altitude: 2000m

    Pollution degree:

    No significant shock or vibration

    Wiring Capacity

    10mm2

    Product Features

    Phase and neutral are both switched when circuit opens or trips because of failure

    Phase connected early and disconnected late

    Screw clamp, shock-proof wiring terminals

    Standard 35mm Din Rail mounting

    RoHS complied

    Rated working voltage: AC230

    Mechanical life: 10000 times

    Tripping characteristic: C: 5-10In

    Rated residual operating current: 30mA

    Breaking capacity: 4.5kA

    Release type: AC, electronic type

    Standards and Certificates

    Number of Poles Part No.

    NDB1L-32

    NDB1L-32

    NDB1L-32

    NDB1L-32

    NDB1L-32

    NDB1L-32

    6

    10

    16

    20

    25

    32

    36

    Width (mm)

    C

    Curve

    30

    Rated ResidualOperating Current (A)

    6

    10

    16

    20

    25

    32

    Rated Current(A)

    7

    B Miniature Circuit Breaker

    NDB1L-32

    1

    L

    32

    C

    6, 10, 16, 20, 25, 32

    1P+N

    T

    36max40

    45

    78m

    ax

    N

    NLOAD

    LINE

    68.5

    70.3max

    5.5

    No. Implication

    Rated residual operating current can be customized upon request, such as 6mA, 10mA, 100mA, etc.

  • 20

    Brand code

    Product code

    Design code

    Residual current protection

    Overvoltage protection

    Frame rating (A)

    Instantaneous tripping characteristic

    Rated current (A)

    NDB1LG Series Residual Current Circuit Breaker with Overload and Overvoltage Protection

    ND B C1 L 32

    19

    Model and Implication

    IEC 61009-1, GB 16917.1; CCC.

    Application

    Working Condition

    Dimension

    Specifications

    TT/TN-S grounding system

    Phase and neutral protection against short circuit, overload, earth leakage and overvoltage

    Ambient temperature: -5+40

    Air humidity: 95%

    Altitude: 2000m

    Pollution degree:

    No significant shock or vibration

    Wiring Capacity

    10mm2

    Product Features

    Phase and neutral are both switched when circuit opens or trips because of failure

    Phase connected early and disconnected late

    Screw clamp, shock-proof wiring terminals

    Standard 35mm Din Rail mounting

    RoHS complied

    Rated working voltage: AC230

    Mechanical life: 10000 times

    Tripping characteristic: C: 5-10In

    Rated residual operating current: 30mA

    Breaking capacity: 4.5kA

    Overvoltage: AC280V5%

    Release type: AC, electronic type

    Standards and Certificates

    Number of Poles

    36

    Width (mm)

    C

    Curve

    30

    Rated ResidualOperating Current (A)

    6

    10

    16

    20

    25

    32

    Rated Current(A)

    8765

    8

    1P+N

    T

    36max40

    45

    78m

    ax

    N

    NLOAD

    LINE

    68.5

    70.3max

    5.5

    G Part No.

    NDB1LG-32

    NDB1LG-32

    NDB1LG-32

    NDB1LG-32

    NDB1LG-32

    NDB1LG-32

    6

    10

    16

    20

    25

    32

    B Miniature Circuit Breaker

    NDB1LG-32

    1

    L

    G

    32C

    6, 10, 16, 20, 25, 32

    No. Implication

    Rated residual operating current can be customized upon request, such as 6mA, 10mA, 100mA, etc.

  • 22

    Brand code

    Product code

    Design code

    Frame rating (A)

    Instantaneous tripping characteristic

    Rated current (A)

    Number of poles

    NDB2-63 Series Miniature Circuit Breaker

    ND B 2 63

    21

    Model and Implication

    UL1077, IEC60898-1, GB 10963.1;

    UL1077, TV, CE, CB, CCC.

    Application

    Working Condition

    Dimension

    Specifications

    Curve B: Non-inductive or micro-inductive loads

    Curve C: Usual inductive loads

    Curve D: Highly inductive loads

    Overload and short circuit protection

    Ambient temperature: -35+70

    Air humidity: 95%

    Altitude: 2000m

    Pollution degree:

    No significant shock or vibration

    Wiring Capacity

    35mm2

    Product Features

    High breaking capacity

    Modularized

    Visual indicator

    Screw clamp, shock-proof wiring terminals

    Numerous accessories available

    Standard 35mm Din Rail mounting

    RoHS complied

    Rated working voltage: AC230/400V, DC60V

    Rated working current: 1A - 63A

    Mechanical life: 20000 times

    Tripping characteristic: B: 3-5In; C: 5-10In; D: 10-14In

    Breaking capacity:

    Standards and Certificates

    Number of Poles

    18

    Width (mm)

    BCD

    Curve

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    B Miniature Circuit Breaker

    NDB2-63

    2

    63

    B, C, D

    1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63

    1, 2, 3, 4

    7 Part No.

    1/1

    2/1

    4/1

    6/1

    10/1

    16/1

    20/1

    25/1

    32/1

    40/1

    50/1

    63/1

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    1P

    2

    1

    18max

    36max

    54max

    72max4P

    3P

    2P

    1P

    21

    45

    60

    74max

    5.5

    45

    81.5

    1~63

    Rated current(A)

    Voltage (V) Breakingcapacity(kA)

    AC230/400 10

    No. Implication

    RatedCurrent (A)

  • Brand code

    Product code

    Design code

    Frame rating (A)

    Instantaneous tripping characteristic

    Rated current (A)

    Number of poles

    2423

    Number of Poles Curve

    B, C, D

    B, C, D

    B, C, D

    Width(mm)

    54

    72

    36

    Part No.

    1/2

    2/2

    4/2

    6/2

    10/2

    16/2

    20/2

    25/2

    32/2

    40/2

    50/2

    63/2

    1/3

    2/3

    4/3

    6/3

    10/3

    16/3

    20/3

    25/3

    32/3

    40/3

    50/3

    63/3

    1/4

    2/4

    4/4

    6/4

    10/4

    16/4

    20/4

    25/4

    32/4

    40/4

    50/4

    63/4

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    NDB2-63

    RatedCurrent (A)

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    1 3 5

    2

    3P

    4 6

    2P

    2 4

    1 3

    NDB2T-63 Series Miniature Circuit Breaker

    ND B 2T 63

    Model and Implication

    IEC60947-2, GB 14048.2; CCC

    Application

    Curve B: Non-inductive or micro-inductive loads

    Curve C: Usual inductive loads

    Curve D: Highly inductive loads

    Overload and short circuit protection

    Standards and Certificates

    B Miniature Circuit Breaker

    NDB2T-63

    2T

    63

    B, C, D

    1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63

    1, 2, 3, 4

    7

    Working Condition Specifications

    Ambient temperature: -35+70

    Air humidity: 95%

    Altitude: 2000m

    Pollution degree:

    No significant shock or vibration

    Wiring Capacity

    35mm2

    Product Features

    High breaking capacity

    Modularized

    Visual indicator

    Screw clamp, shock-proof wiring terminals

    Numerous accessories available

    Standard 35mm Din Rail mounting

    RoHS complied

    Rated working voltage: AC230/400V, DC60V

    Rated working current: 1A - 63A

    Mechanical life: 20000 times

    Rated impulse withstand voltage: 6kV

    Tripping characteristic:

    B: 4In20%; C: 8In20%; D: 12In20%

    Breaking capacity

    1~63

    Rated current(A)

    Voltage (V) Breakingcapacity(kA)

    AC230/400 10

    4P

    1 3 5 7

    2 4 6 8

    No. Implication

  • 2625

    Dimension

    Number of Poles

    18

    Width(mm)

    B, C, D

    Curve

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    Rated Current(A) Part No.

    1/1

    2/1

    4/1

    6/1

    10/1

    16/1

    20/1

    25/1

    32/1

    40/1

    50/1

    63/1

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    1P

    2

    1

    Number of Poles Curve

    B, C, D

    B, C, D

    B, C, D

    Width (mm)

    36

    54

    72

    Part No.

    1/2

    2/2

    4/2

    6/2

    10/2

    16/2

    20/2

    25/2

    32/2

    40/2

    50/2

    63/2

    1/3

    2/3

    4/3

    6/3

    10/3

    16/3

    20/3

    25/3

    32/3

    40/3

    50/3

    63/3

    1/4

    2/4

    4/4

    6/4

    10/4

    16/4

    20/4

    25/4

    32/4

    40/4

    50/4

    63/4

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    NDB2T-63

    Rated Current (A)

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    1 3 5

    2

    3P

    4 6

    4P

    1 3 5 7

    2 4 6 8

    2P

    2 4

    1 3

    18max

    36max

    54max

    72max4P

    3P

    2P

    1P

    21

    4560

    74max

    5.5

    45

    81.5

  • 28

    Brand code

    Product code

    Design code

    Frame rating (A)

    Instantaneous tripping characteristic

    Rated current (A)

    Number of poles

    NDB2-63K Series Miniature Circuit Breaker (1P+N)

    ND B K C2 63

    27

    B Miniature Circuit Breaker

    NDB2-63K

    2

    63

    K

    6, 10, 16, 20, 25, 32, 40, 50, 63

    C

    Model and Implication

    IEC 60898-1, GB 10963.1; CCC

    Application

    Working Condition

    Dimension

    Specifications

    TT/TN-S grounding system

    Phase and neutral protection against short circuit and overload

    Ambient temperature: -35+70

    Air humidity: 95%

    Altitude: 2000m

    Pollution degree:

    No significant shock or vibrationWiring Capacity

    35mm2

    Product Features

    Phase and neutral are both switched when circuit opens or trips because of failure

    Phase connected early and disconnected late

    Screw clamp, shock-proof wiring terminals

    Standard 35mm Din Rail mounting

    Rated working voltage: AC230V

    Mechanical life: 20000 times

    Trip characteristic: C: 5-10In

    Breaking capacity: 6kA

    Standards and Certificates

    Number of Poles Part No.

    NDB2-63K

    NDB2-63K

    NDB2-63K

    NDB2-63K

    NDB2-63K

    NDB2-63K

    NDB2-63K

    NDB2-63K

    NDB2-63K

    6

    10

    16

    20

    25

    32

    40

    50

    63

    36

    Width (mm)

    C

    Curve

    6

    10

    16

    20

    25

    32

    40

    50

    63

    Rated Current (A)

    36max

    74max

    60

    45

    45

    21

    5.5

    81.5

    71P+N

    No. Implication

  • 30

    Brand code

    Product code

    Design code

    DC

    Frame rating (A)

    Instantaneous tripping characteristic

    Rated current (A)

    Number of poles

    No.

    NDB2Z-63 Series DC Miniature Circuit Breaker

    ND B 2 Z 63

    29

    Model and Implication

    UL1077, IEC60898-2, GB 10963.2;

    UL1077, TV, CE, CB, CCC.

    Application

    Working Condition

    Dimension

    Specifications

    Curve B: DC non-inductive or micro-inductive loads

    Curve C: DC usual inductive loads

    Overload and short circuit protection

    Ambient temperature: -35~+70

    Air humidity: 95%

    Altitude: 2000m

    Pollution degree:

    No significant shock or vibration

    Wiring Capacity

    35mm2

    Product Features

    High breaking capacity

    Modularized

    Visual indicator

    Screw clamp, shock-proof wiring terminals

    Numerous accessories available

    Standard 35mm Din Rail mounting

    RoHS complied

    Mechanical life: 20000 times

    Tripping characteristic: B: 4-7In; C: 7-15In

    Standards and Certificates

    Number of Poles

    18

    Width (mm)

    B, C

    Curve

    7 8

    8

    B Miniature Circuit Breaker

    NDB2Z-63

    2

    Z

    63

    B, C

    1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63

    1, 2

    Pole number

    1P

    2P, 3P, 4P

    1P

    2P, 3P, 4P

    1~63A

    1~63A

    Rated current(A)

    DC125V

    DC250V

    DC220V

    DC440V

    Voltage (V)

    10kA

    6kA

    Breakingcapacity (kA)

    Part No.

    NDB2Z-63 1/1

    NDB2Z-63 2/1

    NDB2Z-63 4/1

    NDB2Z-63 6/1

    NDB2Z-63 10/1

    NDB2Z-63 16/1

    NDB2Z-63 20/1

    NDB2Z-63 25/1

    NDB2Z-63 32/1

    NDB2Z-63 40/1

    NDB2Z-63 50/1

    NDB2Z-63 63/1

    Rated Current (A)

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    1P

    1

    2

    36max

    74max

    60

    45

    45

    21

    5.5

    81.5

    Implication

  • Brand code

    Product code

    Design code

    Residual current release

    Electronic type

    Frame rating (A)

    Instantaneous tripping characteristic

    Rated current (A)

    Number of poles

    32

    NDB2LE Series Residual Current Modular

    ND B 2 L

    Model and Implication

    IEC 61009-1, GB 16917.1;

    TV, CE, CCC.

    Application

    Protection against earth leakage faults

    Standards and Certificates

    Dimension (With MCB)

    E 63

    89

    B Miniature Circuit Breaker

    NDB2LE

    2

    L

    E

    63

    B, C, D

    1, 2, 4, 6, 10, 16, 20, 25, 32, 40, 50, 63

    1PN, 2P, 3P, 3PN, 4P

    987

    Working Condition

    1PN, 2P

    Specifications

    Ambient temperature: -5+40

    Air humidity: 95%

    Altitude: 2000m

    Pollution degree:

    No significant shock or vibration

    RoHS complied

    Wiring Capacity

    35mm2

    Rated working voltage: AC230V (1PN, 2P)

    AC400V (3P, 3PN, 4P)

    Rated residual operating current: 30mA(6mA, 10mA, 100mA, 300mA can be customized)

    Release type: AC, electronic

    31

    Number of Poles Width (mm)

    36

    Part No.

    Wiring Schametics

    NDB2Z-63 1/2

    NDB2Z-63 2/2

    NDB2Z-63 4/2

    NDB2Z-63 6/2

    NDB2Z-63 10/2

    NDB2Z-63 16/2

    NDB2Z-63 20/2

    NDB2Z-63 25/2

    NDB2Z-63 32/2

    NDB2Z-63 40/2

    NDB2Z-63 50/2

    NDB2Z-63 63/2

    Rated Current (A)

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    2P

    1 3

    2 4

    7254

    2P

    7560

    45

    45 90.5

    1PN

    1

    2

    L- L+

    +-

    L- L+

    1 3

    2

    + -

    L+ L-

    1 3

    L- L+

    L-L+

    1 3

    1

    2

    -+

    + 4

    3

    +-

    L- L+M

    1

    2 + 4

    3

    L+ L- M

    -+

    +-

    1P (A)

    2P (D)

    2P (B) 2P (C)

    1 3

    Load

    Top Leading-in Top Leading-in Bottom Leading-in Top Leading-in Bottom Leading-in

    Top Leading-in Bottom Leading-in

    Notes:

    1) L+: Positive pole of power

    L-: Negative pole of power

    2) Positive pole of breaker Negative pole of breaker3) Normally Lgrounds in DC power system

    while neutral line Mgrounds in AC power system.

    +

    For 3-pole and 4-pole NDB2Z-63 series MCB can be ordered upon special request.

    No. Implication

  • 34

    3P, 3PN, 4P

    33

    2P

    2 4

    1 3

    Number of Poles Curve

    B, C, D

    B, C, D

    Width(mm)

    54

    72

    Rated Current(A)

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    1PNN

    N 2

    1

    Part No.

    NDB2LE-63 1/1PN

    NDB2LE-63 2/1PN

    NDB2LE-63 4/1PN

    NDB2LE-63 6/1PN

    NDB2LE-63 10/1PN

    NDB2LE-63 16/1PN

    NDB2LE-63 20/1PN

    NDB2LE-63 25/1PN

    NDB2LE-63 32/1PN

    NDB2LE-63 40/1PN

    NDB2LE-63 50/1PN

    NDB2LE-63 63/1PN

    NDB2LE-63 1/2

    NDB2LE-63 2/2

    NDB2LE-63 4/2

    NDB2LE-63 6/2

    NDB2LE-63 10/2

    NDB2LE-63 16/2

    NDB2LE-63 20/2

    NDB2LE-63 25/2

    NDB2LE-63 32/2

    NDB2LE-63 40/2

    NDB2LE-63 50/2

    NDB2LE-63 63/2

    Release should be released first during MCB dielectric test

    NDB2LE-63 3PN can be ordered upon special request

    Number of Poles Width (mm)

    117

    135

    135

    Curve

    B, C, D

    B, C, D

    B, C, D

    Rated Current(A)

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    1

    2

    4

    6

    10

    16

    20

    25

    32

    40

    50

    63

    3PN

    N 1 3 5

    N 2 4 6

    4P

    1 3 5 7

    2 4 6 8

    3P

    1 3 5

    2 4 6

    Part No.

    NDB2LE-63 1/3

    NDB2LE-63 2/3

    NDB2LE-63 4/3

    NDB2LE-63 6/3

    NDB2LE-63 10/3

    NDB2LE-63 16/3

    NDB2LE-63 20/3

    NDB2LE-63 25/3

    NDB2LE-63 32/3

    NDB2LE-63 40/3

    NDB2LE-63 50/3

    NDB2LE-63 63/3

    NDB2LE-63 1/3PN

    NDB2LE-63 2/3PN

    NDB2LE-63 4/3PN

    NDB2LE-63 6/3PN

    NDB2LE-63 10/3PN

    NDB2LE-63 16/3PN

    NDB2LE-63 20/3PN

    NDB2LE-63 25/3PN

    NDB2LE-63 32/3PN

    NDB2LE-63 40/3PN

    NDB2LE-63 50/3PN

    NDB2LE-63 63/3PN

    NDB2LE-63 1/4

    NDB2LE-63 2/4

    NDB2LE-63 4/4

    NDB2LE-63 6/4

    NDB2LE-63 10/4

    NDB2LE-63 16/4

    NDB2LE-63 20/4

    NDB2LE-63 25/4

    NDB2LE-63 32/4

    NDB2LE-63 40/4

    NDB2LE-63 50/4

    NDB2LE-63 63/4

    75135

    1173PN, 4P

    3P

    60

    45

    45 90.5

    Dimension

  • Brand code

    Product code

    Design code

    Frame rating (A)

    Rated current (A)

    Number of poles

    3635

    OF2 Auxiliary Switch

    Application

    Linked to the left side of NDB2 series MCB, to indicate the OPEN or CLOSED status of the associated breaker

    Specifications

    Width (mm): 9

    AC

    DC

    DC

    Voltage

    415V

    130V

    24V

    Current

    3A

    1A

    6A

    AC

    DC

    Voltage

    240V

    48V

    Current

    6A

    2A

    SD2 Alarm Switch

    Wiring Capacity

    Application

    Linked to the left side of NDB2 series MCB, to indicate the tripping status of the associated breaker

    Specifications

    Width (mm): 9

    AC

    DC

    DC

    Voltage

    415V

    130V

    24V

    Current

    3A

    1A

    6A

    AC

    DC

    Voltage

    240V

    48V

    Current

    6A

    2A

    Single line: 2.5mm2 Double line: 1.5mm2

    11

    12 14

    949291

    NDG1 Series Disconnect Switch

    ND G 1 100

    G Switch Disconector

    NDG1-100

    1

    100

    32, 63, 100

    1, 2, 3, 4

    Model and Implication

    IEC 60947-3, GB 14048.3;

    TV, CE, CCC.

    Application

    Close, open or disconnect the circuit

    Standards and Certificates

    Working Condition

    Ambient temperature: -35+70

    Air humidity: 95%

    Altitude: 2000m

    Pollution degree:

    No significant shock or vibration

    Wiring Capacity

    4mm2 , 50 4mm2 (Minimum 4mm2 for BV)

    Specifications

    Rated working voltage: AC230/400V

    Mechanical life: 10000 times

    Switching capacity:3InA(400V, cos=0.65)

    Rated short current making capacity:2000A(400V, cos=0.9)

    Rated short-time withstand current2000A(400V, 1s)

    IEC 60947-5, GB 14048.5;

    TV, CE, CCC.

    Standards and Certificates

    Notes: After clipping on to NDB2 series MCB, Point 11 and 14 are connected when circuit is closed; Point 11 and 12 are connected when circuit is open. May be used in conjunction with a SD2 alarm switch or another OF2 auxiliary switch.

    Notes: After clipping on to NDM1 series MCB,Point 91 and 92 are connected when circuit is closed;Point 91 and 94 are connected when the breaker trips due to fault;Point 91 and 92 are connected when the breaker trips by manual operation. Meanwhile, point 91 and 94 are disconnected.May be used in conjunction with a OF2 auxiliary switch or another SD2 alarm switch.

    No. Implication

  • 3837

    Number of Poles Width (mm)

    18

    18

    18

    36

    36

    36

    54

    54

    54

    72

    72

    72

    Part No.

    32/1

    63/1

    100/1

    32/2

    63/2

    100/2

    32/3

    63/3

    100/3

    32/4

    63/4

    100/4

    NDG1-100

    NDG1-100

    NDG1-100

    NDG1-100

    NDG1-100

    NDG1-100

    NDG1-100

    NDG1-100

    NDG1-100

    NDG1-100

    NDG1-100

    NDG1-100

    Rated Current (A)

    32

    63

    100

    32

    63

    100

    32

    63

    100

    32

    63

    100

    AC 250V 6A

    AC 415V 3A

    11

    1214

    OF3 Auxiliary Switch

    Application

    Linked to the left side of NDG1-100 series disconnect switch to indicate the OPEN or CLOSED status

    Specification

    Standards and Certificates

    Width (mm): 18

    Note: Clip onto NDG1-100 switch disconnector.

    Point 11 and 14 is connected when circuit is closed;

    Point 11 and 12 is connected when circuit is opened.

    IEC 60947-5, GB 14048.5;

    TV, CE, CCC

    Wiring Capacity

    Tripping Curve

    5

    21

    10000 5000

    1h20001000

    500

    200100

    50

    2010

    0.5

    0.20.1

    0.05

    0.020.01

    0.005

    0.0020.001

    0.5 1 2 3 4 5 7 10 20 30 5070100200 l/ln

    Curve B (3~5In)

    NDM1-63, NDB2-63, NDB2LE-63

    5

    21

    10000 5000

    1h20001000

    500

    200100

    50

    2010

    0.5

    0.20.1

    0.05

    0.020.01

    0.005

    0.0020.001

    0.5 1 2 3 4 5 7 10 20 30 5070100200 l/ln

    Curve C (5~10In)

    NDM1-63, NDB2-63, NDB2LE-63NDB1-32, NDB1LG-32

    10mm2

    Curve D (10~14In)

    NDM1-63, NDB2-63, NDB2LE-63

    5

    21

    10000 5000

    1h20001000

    500

    200100

    50

    2010

    0.5

    0.20.1

    0.05

    0.020.01

    0.005

    0.0020.001

    0.5 1 2 3 4 5 7 10 20 30 5070100200 l/ln

  • 4039

    Tripping Curve Temperature Derating

    Curve C 8In (120%)

    NDM1-125

    5

    21

    10000 5000

    1h20001000

    500

    200100

    50

    2010

    0.5

    0.20.1

    0.05

    0.020.01

    0.005

    0.0020.001

    0.5 1 2 3 4 5 7 10 20 30 5070100200 l/ln

    Curve D 12In (120%)

    NDM1-125

    5

    21

    10000 5000

    1h20001000

    500

    200100

    50

    2010

    0.5

    0.20.1

    0.05

    0.020.01

    0.005

    0.0020.001

    0.5 1 2 3 4 5 7 10 20 30 5070100200 l/ln

    Curve B (4~7In)

    NDB2Z-63

    0.5 1 2 3 4 5 7 10 20 30 5070100200 l/ln

    10000 5000

    1h20001000

    500

    200100

    50

    2010

    0.5

    0.20.1

    0.05

    0.020.01

    0.005

    0.0020.001

    Curve C (7~15In)

    NDB2Z-63

    0.5 1 2 3 4 5 7 10 20 30 5070100200 l/ln

    10000 5000

    1h20001000

    500

    200100

    50

    2010

    0.5

    0.20.1

    0.05

    0.020.01

    0.005

    0.0020.001

    (A)

    ()

    1

    3

    6

    10

    16

    20

    25

    32

    40

    50

    63

    80

    100

    125

    1.25

    3.83

    7.58

    13.62

    20.43

    25.28

    31.72

    40.46

    50.86

    63.97

    82.06

    130

    155

    265

    -30

    1.27

    3.89

    7.70

    13.89

    20.78

    25.67

    32.21

    41.04

    51.63

    64.92

    83.48

    135

    160

    275

    -35

    1.23

    3.76

    7.46

    13.35

    20.08

    24.88

    31.22

    39.82

    50.04

    62.92

    80.64

    126

    150

    255

    -25

    1.21

    3.70

    7.34

    13.07

    19.75

    24.47

    30.70

    39.17

    40.21

    61.86

    79.19

    122

    146

    245

    -20

    1.19

    3.64

    7.21

    12.81

    19.40

    24.06

    30.18

    38.51

    48.37

    60.77

    77.72

    118

    142

    235

    -15

    1.17

    3.57

    7.09

    12.53

    19.05

    23.64

    29.65

    37.84

    47.51

    59.67

    76.22

    115

    137

    225

    -10

    1.15

    3.50

    6.96

    12.23

    18.70

    23.22

    29.10

    37.15

    46.63

    58.54

    74.70

    112

    133

    215

    -5

    1.13

    3.44

    6.83

    11.93

    18.33

    22.78

    28.55

    36.47

    45.74

    57.40

    73.14

    108

    129

    205

    0

    1.10

    3.37

    6.70

    11.63

    17.96

    22.34

    27.98

    35.75

    44.83

    56.23

    71.54

    104

    125

    195

    5

    1.08

    3.30

    6.56

    11.33

    17.58

    21.89

    27.41

    35.03

    43.90

    55.05

    69.91

    99

    122

    185

    10 15

    1.06

    3.22

    6.42

    11.01

    17.20

    21.43

    26.82

    34.30

    42.95

    53.81

    68.24

    95

    118

    175

    1

    3

    6

    10

    16

    20

    25

    32

    40

    50

    63

    80

    100

    125

    20

    1.05

    3.14

    6.27

    10.67

    16.80

    20.96

    26.22

    33.54

    41.98

    52.56

    66.53

    91

    114

    165

    25

    1.02

    3.06

    6.14

    10.34

    16.40

    20.47

    25.61

    32.77

    40.99

    51.28

    64.78

    88

    111

    155

    30

    1.00

    3.00

    6.00

    10.00

    16.00

    20.00

    25.00

    32.00

    40.00

    50.00

    63.00

    85

    108

    145

    35

    0.97

    2.92

    5.84

    9.63

    15.55

    19.47

    24.33

    31.17

    38.93

    47.82

    60.11

    82

    103

    135

    40

    0.94

    2.84

    5.68

    9.24

    15.11

    18.95

    23.67

    30.34

    37.85

    46.24

    58.19

    80

    100

    125

    45

    0.91

    2.76

    5.52

    8.85

    14.66

    18.42

    23.00

    29.48

    36.75

    44.81

    56.21

    75.5

    94

    115

    50

    0.89

    2.67

    5.36

    8.45

    14.20

    17.87

    22.28

    28.60

    35.61

    43.33

    54.16

    72.5

    88

    105

    55

    0.86

    2.58

    5.19

    8.01

    13.71

    17.30

    21.56

    27.69

    34.43

    41.81

    52.03

    68

    82

    95

    60

    0.83

    2.49

    5.01

    7.55

    13.21

    16.71

    20.80

    26.75

    33.21

    40.23

    49.81

    64.5

    75

    85

    65

    0.80

    2.38

    4.83

    7.06

    12.70

    16.10

    20.02

    25.78

    31.95

    38.58

    47.50

    58

    68

    75

    70

    0.77

    2.27

    4.64

    6.55

    12.75

    15.47

    19.21

    24.77

    30.63

    35.77

    43.05

    52.5

    58

    65

    Note: Ambient temperature refers to the temperature inside the distribution board or switchgear where breakers are

    mounted. For breakers below 63A, the reference number is 30, while 40 for breakers from 80A to 125A.

    5

    21

    10000 5000

    1h20001000

    500

    200100

    50

    2010

    0.5

    0.20.1

    0.05

    0.020.01

    0.005

    0.0020.001

    0.5 1 2 3 4 5 7 10 20 30 5070100200 l/ln

    Curve B 4In (120%)

    NDB2T-63

    5

    21

    10000 5000

    1h20001000

    500

    200100

    50

    2010

    0.5

    0.20.1

    0.05

    0.020.01

    0.005

    0.0020.001

    0.5 1 2 3 4 5 7 10 20 30 5070100200 l/ln

    Curve C 8In (120%)

    NDB2T-63

    Curve D 12In (120%)

    NDB2T-63

    5

    21

    10000 5000

    1h20001000

    500

    200100

    50

    2010

    0.5

    0.20.1

    0.05

    0.020.01

    0.005

    0.0020.001

    0.5 1 2 3 4 5 7 10 20 30 5070100200 l/ln

    Rated current

    Ambienttemperature

    (A)

    ()Rated current

    Ambienttemperature

    Correcting current (A)

    Correcting current (A)

  • 42

    Brand code

    Product code

    Design code

    Rated current (A)

    Number of holes

    Width modular

    NDA1 Series Modular Socket

    ND A 1

    41

    A Modular Socket

    NDA1

    1

    10, 16, 25

    2, 3, 4

    2, 4, 6, 8

    Model and Implication

    IEC 60884-1, GB 2099.1; CCC.

    Standards and Certificates

    Connect electric equipment

    Modularization

    Standard TH35mm mounting

    RoHS complied

    Product Features

    Schematic Part No.

    NDA1-10/22

    NDA1-16/34

    NDA1-16/46

    Specification

    Single phase,

    two holes

    Single phase,

    three holes

    Three phase,

    four holes

    Three phase,

    four holesNDA1-25/48

    18

    36

    Width (mm)

    54

    72

    10

    16

    Rated Current(A)

    16

    25

    250

    250

    440

    440

    Rated WorkingVoltage (V)

    2: Single phase, two holes

    3: Single phase, three holes

    4: Three phase, four holes

    Rated current

    Number of Holes

    Width modular One modular width: 9mm

    25A

    4

    8

    16A

    4

    4 6

    3

    10A

    2

    2

    No. Implication

  • 44

    Brand code

    Product code

    Design code

    Frame rating (A)

    Number of p ooles

    Width (mm)

    NDH1 Series Busbar

    ND H 1

    H Busbar

    NDH1

    1

    63, 100

    43

    1P, 2P, 3P

    Model and Implication

    Consist of comb copper bar and insulated cover.

    Use T2 pure copper plate for copper bar and enhanced flame retardant PVC for insulated cover.

    Compact and simple usage.

    IP20 Protection degree

    Product Features

    By pole number: 1-Pole, 2-Pole, 3-Pole

    By length: Multiple of 18mm, also can be customized, and 60 kits at most (1080 mm).

    By kit number: the poles that are linked.

    Product Type

    Specification

    Rated insulation voltage: 500V

    Rated current: up to 100A

    Conventional thermal current: 100A

    Impulse voltage withstand: 6kV

    Short-time withstand current: 25kA/0.5s

    Power frequency voltage withstand: 2500V (AC 50Hz); No breakdown and flashover within 1 minutes.

    Application

    NDH1 series busbar is used to link MCB line terminals of the same phase. It can also be used to link terminal apparatus in the same way.

    No. Implication

  • 46

    Brand code

    Product code

    Design code

    Frame rating (A)

    Number of poles

    Width (mm)

    NDH2 Series Busbar

    45

    Application

    NDH2-63 series busbar is used to link MCB line terminals of the same phase. It can also be used to link

    terminal apparatus in the same way.

    ND H 2

    H Busbar

    NDH2

    2

    63

    1P, 3P

    Model and Implication

    63

    Consist of comb copper bar and insulated cover.

    Use T2 pure copper plate for copper bar and enhanced flame retardant PVC for insulated cover.

    Compact and simple usage.

    IP20 Protection degree

    Product Features

    By pole number: 1-Pole, 3-Pole

    By length: Multiple of 18mm, also can be customized, and 60 kits at most (1080 mm).

    By kit number: the poles that are linked.

    Product Type

    Specification

    Rated insulation voltage: 500V

    Rated current: up to 100A

    Conventional thermal current: 63A

    Impulse voltage withstand: 6kV

    Short-time withstand current: 25kA/0.5s

    Power frequency voltage withstand: 2500V (AC 50Hz); No breakdown and flashover within 1 minutes

    No. Implication

    MCB P01-02MCB P03-04MCB P05-06MCB P07-08MCB P09-10MCB P11-12MCB P13-14MCB P15-16MCB P17-18MCB P19-20MCB P21-22MCB P23-24MCB P25-26MCB P27-28MCB P29-30MCB P31-32MCB P33-34MCB P35-36MCB P37-38MCB P39-40MCB P41-42MCB P43-44MCB P45-46MCB P47-48