ELTEL INDUSTRIES CALIBRATION LABORATORY
NABL ACCREDITED
NABL ACCREDITEDELTEL INDUSTRIES - CALIBRATION LABORATORY
The Eltel Industries - Calibration Lab is equipped with
customized world class standards to calibrate
instruments designed for use by transformer
manufacturers and power utilities.
Eltel Industries, being a manufacturer, has a deep
technical understanding of calibration requirements.
The advantage of getting the equipment calibrated at
our Calibration Lab is the assurance that the calibration
charges will be appropriate for the entire range rather
than for specific calibration points. Eltel Industries takes
pride in offering calibration services on par with
International Standards - we look forward to working
with you.
The laboratory is now open for performing calibration activities with the following unique standards on board. • Precision Current Transformer with accuracy of
0.002% and best CMC of 60 PPM.• CVRPS -2013 to calibrate Instrument Transformer
Test Sets for both Ratio Error and Phase error(Direct method).
• Power analyzer to calibrate Current transformer burdens and Voltage Transformer burden.
• Capacitance & Tan Delta Standard up to 10 kV.• High Resistance Standards (1kΩ to 10 TΩ). • Low Resistance Standards (1mΩ to 1 KΩ). • Fluke 5080 A Calibrator. • Fluke 8846A 6½ Digit Multimeter.
We are pleased to announce the NABL accreditation of the Eltel Industries- Calibration Laboratory in Electro - technical discipline in accordance to ISO/ IEC:17025/2005.
PRECISION CURRENT TRANSFORMER CALIBRATION SET UP
CURRENT & VOLTAGE TRANSFORMER RATIO AND PHASE ERROR STANDARD – CVRPS 2013
AUTOMATIC INSTRUMENT TRANSFORMER TEST SET - AITTS 98
2
PRECISION CURRENT TRANSFORMER (20 PPM)
The precision Current Transformer along with
7200A High Current source covers ratios from
5A/ 5A : 5A / 1A all the way upto 6000A/ 5A :
6000/1A with best overall uncertainty of 60 PPM
– which is on par with the best calibration
laboratories. The ratio range provided covers
all typically manufactured standard and
commercial grade Current Transformers.
The CVRPS generates fixed Ratio and Phase
Errors that enable the calibration of Instrument
Current Transformer Test Sets and Instrument
Voltage Transformer Test Sets using Direct
Method. This unique standard allows the
calibration of test equipments at different
ranges of Ratio and Phase Errors. This facility is
unique to the Eltel Industries – Calibration
Laboratory and to the best of our knowledge,
is not currently available in any other NABL
accredited labs. The best uncertainty of
80 ppm, 0.4 min is class leading and best
available in the Industry.
This is a high accuracy comparator
manufactured by Eltel Industries. This is used to
calibrate Current Transformers and Voltage
Transformers for Ratio Error & Phase Error. It has a
best uncertainty of 55 PPM.
TRANSFORMER RATIO STANDARD - TRS 5000
HIGH RESISTANCE STANDARD
CAPACITANCE & TAN DELTA STANDARD SET UP
3
This standard set up comprises of a SF6 filled
Standard Capacitor, a Step down Voltage
Transformer (11kV/ 110 V) & Dissipation Factor
Error Standard. The Standard is capable of
introducing Tan Delta from 0% to 10%. Using this
standard set up, the Capacitance & Tan Delta
Test Sets can be calibrated up to 10 kV. The best
uncertainty 0.3% for Capacitance & 0.02% for
Tan Delta.
This is a Precision Turns Ratio Standard
developed by Eltel Industries for their Calibration
Laboratory. It has a Ratio Range from 1/1 to
5,000/1. Used for calibration of manual and
Automatic Single and Three phase Transformer
Ratio Meters. The accuracy is better than 0.01%
over the entire range.
This High Resistance Standard is manufactured
by an Industry pioneer and offers resistance
ranges from 1KΩ to 10 TΩ. It is used to calibrate
High Resistance Insulation Test Sets, Tan Delta
and Resistivity Test Sets.
5080A MULTI PRODUCT CALIBRATOR
6½ DIGIT PRECISION MULTIMETER
LOW RESISTANCE STANDARD
DIGITAL POWER ANALYZER - WT210
This set of Precision Low and Medium Resistance
Standards is from a leading Resistance
manufacturer of discrete standards. We have a
best uncertainty of 0.02% ranging from 1milliΩ
to 1kΩ. They are used to calibrate low resistance
Ohm Meters, Transformers Winding Resistance
Meters.
The Power analyzer with a best uncertainty
of 0.37% is used for calibrating Current
Transformer Burdens and Voltage
Transformer Burdens.
This is a Fluke Universal 5½ digit Calibrator
and has the highest compliance with
maximum burden up to 800 milli amps for
AC and DC voltages and a voltage up to
50V for AC and DC currents. This unit is used
to calibrate Multimeters and also used as a
AC Current and Voltage source.
This Fluke Standard Meter is capable of
calibrating any 5½ digit calibrators. It is also
used to calibrate any AC, DC current and
Voltage Sources and Resistances.
4
ELTEL INDUSTRIES - CALIBRATION LABORATORY
SCOPE OF ACCREDITATIONSOURCE
Sl. Parameter / Range / *Calibration Remarks / Standard equipmentNo. Instrument Frequency Measurement Capability (+/-) & Method Used
1 DC Resistance 0.001 Ω 0.065 % Using Vaiseshika STD Resistance
0.01 Ω 0.065 % by Direct Method
0.1 Ω 0.02 %
2 Ω 0.07 %
10 Ω 0.02 %
1000 Ω 0.02 %
2 DC High Resistance 1 kΩ to 1 MΩ 31 ppm Using IET-VRS -100 High Resistance
10 MΩ 100 ppm STD by Direct Method
100 MΩ 0.02%
1 GΩ 0.6%
10 GΩ 0.6%
100 GΩ 1.2%
1 TΩ 2.4%
3 Ratio and Phase Error for 100 V @ 50 Hz Ratio Error: 80 to 225 ppm Using Eltel CVRPS -2013
Instrument Transformer Ratio Error : ± 0% to 3% Phase Error: 0.4 min to 0.8 min Calibrator by Direct method
Test Set (VT) Phase Error : ±0 crad to 3 crad
4 Ratio and Phase Error for 1A & 5A @ 50 Hz Ratio Error: 80 to 225 ppm Using Eltel CVRPS - 2013
Instrument Transformer Ratio Error : ± 0 % to 3% Phase Error: 0.4 min to 0.8 min Calibrator by Direct method
Test Set (CT 1A & 5A) Phase Error : ± 0 crad to 3 crad
5 Capacitance and 200 pF, Capacitance: 0.6 pF Using Eltel STD Capacitor and
TANδ (Dissipation factor) 0.05% to 10% Tanδ: 0.02% to 0.08% C&DF Calibrator by Direct Method
up to 10 kV @ 50 Hz
6 DC Voltage 329 mV to 32 V 0.019% to 0.012% Using Fluke
32 V to 1000 V 0.012% to 0.016% Calibrator - 5080A by Direct Method
Sl. Parameter / Range / *Calibration Remarks/ Standard equipmentNo. Instrument Frequency Measurement Capability (+/-) & Method Used
7 DC Current 329 µA to 3.2 mA 0.13% to 0.076% Using Fluke
3.2 mA to 32 mA 0.076% to 0.060% Calibrator-5080A by Direct Method
32 mA to 329 mA 0.060% to 0.077%
329 mA to 1 A 0.077% to 0.18%
1 A to 20 A 0.18% to 0.59%
8 AC Voltage @ 50Hz 32 mV to 329 mV 0.60% to 0.20% Using Fluke
329 mV to 32 V 0.20% to 0.13% Calibrator-5080A by Direct Method
32 V to 1000 V 0.13% to 0.37%
9 AC Current @ 50Hz 329 µA to 3.2 mA 0.56% to 0.26% Using Fluke
3.2 mA to 2.99 A 0.26% to 0.13% Calibrator-5080A by Direct Method
2.99 A to 10 A 0.13% to 0.3%
10 A to 20 A 0.3% to 0.60%
10 DC Resistance 1 Ω to 10 Ω 1.3% to 0.18% Using Fluke
(Discrete) 10 Ω to 100 Ω 0.18% to 0.047% Calibrator-5080A by Direct Method
100 Ω to 10 kΩ 0.047% to 0.03%
10 kΩ to 1 MΩ 0.03% to 0.052%
1 MΩ to 100 MΩ 0.052% to 0.58%
100 MΩ to 190 MΩ 0.58% to 1.3%
11 Frequency 45 Hz to 1 kHz 0.011% to 0.006% Using Fluke
Calibrator-5080A by Direct Method
5
ELTEL INDUSTRIES - CALIBRATION LABORATORY
Sl. Parameter / Range / *Calibration Remarks / Standard equipmentNo. Instrument Frequency Measurement Capability (+/-) & Method Used
1 DC Resistance 0.001 Ω 0.065 % Using Vaiseshika STD Resistance
0.01 Ω 0.065 % by Direct Method
0.1 Ω 0.02 %
2 Ω 0.07 %
10 Ω 0.02 %
1000 Ω 0.02 %
2 DC High Resistance 1 kΩ to 1 MΩ 31 ppm Using IET-VRS -100 High Resistance
10 MΩ 100 ppm STD by Direct Method
100 MΩ 0.02%
1 GΩ 0.6%
10 GΩ 0.6%
100 GΩ 1.2%
1 TΩ 2.4%
3 Ratio and Phase Error for 100 V @ 50 Hz Ratio Error: 80 to 225 ppm Using Eltel CVRPS -2013
Instrument Transformer Ratio Error : ± 0% to 3% Phase Error: 0.4 min to 0.8 min Calibrator by Direct method
Test Set (VT) Phase Error : ±0 crad to 3 crad
4 Ratio and Phase Error for 1A & 5A @ 50 Hz Ratio Error: 80 to 225 ppm Using Eltel CVRPS - 2013
Instrument Transformer Ratio Error : ± 0 % to 3% Phase Error: 0.4 min to 0.8 min Calibrator by Direct method
Test Set (CT 1A & 5A) Phase Error : ± 0 crad to 3 crad
5 Capacitance and 200 pF, Capacitance: 0.6 pF Using Eltel STD Capacitor and
TANδ (Dissipation factor) 0.05% to 10% Tanδ: 0.02% to 0.08% C&DF Calibrator by Direct Method
up to 10 kV @ 50 Hz
6 DC Voltage 329 mV to 32 V 0.019% to 0.012% Using Fluke
32 V to 1000 V 0.012% to 0.016% Calibrator - 5080A by Direct Method
Sl. Parameter / Range / *Calibration Remarks/ Standard equipmentNo. Instrument Frequency Measurement Capability (+/-) & Method Used
7 DC Current 329 µA to 3.2 mA 0.13% to 0.076% Using Fluke
3.2 mA to 32 mA 0.076% to 0.060% Calibrator-5080A by Direct Method
32 mA to 329 mA 0.060% to 0.077%
329 mA to 1 A 0.077% to 0.18%
1 A to 20 A 0.18% to 0.59%
8 AC Voltage @ 50Hz 32 mV to 329 mV 0.60% to 0.20% Using Fluke
329 mV to 32 V 0.20% to 0.13% Calibrator-5080A by Direct Method
32 V to 1000 V 0.13% to 0.37%
9 AC Current @ 50Hz 329 µA to 3.2 mA 0.56% to 0.26% Using Fluke
3.2 mA to 2.99 A 0.26% to 0.13% Calibrator-5080A by Direct Method
2.99 A to 10 A 0.13% to 0.3%
10 A to 20 A 0.3% to 0.60%
10 DC Resistance 1 Ω to 10 Ω 1.3% to 0.18% Using Fluke
(Discrete) 10 Ω to 100 Ω 0.18% to 0.047% Calibrator-5080A by Direct Method
100 Ω to 10 kΩ 0.047% to 0.03%
10 kΩ to 1 MΩ 0.03% to 0.052%
1 MΩ to 100 MΩ 0.052% to 0.58%
100 MΩ to 190 MΩ 0.58% to 1.3%
11 Frequency 45 Hz to 1 kHz 0.011% to 0.006% Using Fluke
Calibrator-5080A by Direct Method
6
SCOPE OF ACCREDITATIONSOURCE
ELTEL INDUSTRIES - CALIBRATION LABORATORY
Sl. Parameter / Range / *Calibration Remarks/ Standard equipmentNo. Instrument Frequency Measurement Capability (+/-) & Method Used
1 Current Transformer 1 VA - 5 VA @ UPF, 50 Hz 0.8% to 0.4% Using Yokogawa - WT210 Power Burden (1 A & 5 A) 2.5 VA- 40 VA @ 0.8 PF, 50 Hz Analyzer & DMM 8846A by Direct Method
2 Voltage Transformer 2.5 VA to 80 VA @ UPF, 50 Hz 0.37% Using Yokogawa - WT210 Power Burden (110 V & 63.5 V) Analyzer & DMM 8846A by Direct Method
3 Current Transformer Primary Ratio Error 10% to 120%:60 ppm Using Eltel STD CT-2509A, Ratio Error 5A - 6000 A 5% to 10% :105 ppm STD AITTS-98, by Comparison method and Phase Error Secondary 1% to 5 % :150 ppm
5 A &1 A @ 50 Hz Phase Error 10% to 120% : 0.6 min 5% to 10 % :1.2 min
1% to 5% : 2.3 min
4 DC Voltage 100 mV to 10 V 0.01% to 0.0034% Using Fluke 6½ DMM 8846A
10 V to 100 V 0.0034% to 0.0052% by Direct Method
100 V to 1000 V 0.0052% to 0.0060%
5 DC Current 100 µA to 1 mA 0.09% to 0.086% Using Fluke 6½ DMM 8846A
1 mA to 100 mA 0.086% to 0.064% by Direct Method
100 mA to 1 A 0.064% to 0.082%
1 A to 10 A 0.082% to 0.21%
6 AC Voltage 100 mV to 1000 V @ 50 Hz 0.12% to 0.10% Using Fluke 6½ DMM 8846A
by Direct Method
7 AC Current 100 µA to 10 mA @ 50 Hz 0.17% Using Fluke 6½ DMM 8846A
10 mA to 1A @ 50 Hz 0.17% by Direct Method
1 A to 10 A @ 50 Hz 0.17% to 0.25%
8 DC Resistance 10 Ω to 100 Ω 0.046% to 0.016% Using Fluke 6½ DMM 8846A
100 Ω to 1 MΩ 0.016% to 0.013% by Direct Method
1 MΩ to 10 MΩ 0.013% to 0.047%
10 MΩ to 1 GΩ 0.047% to 2.4%
9 Frequency 45 Hz to 1 kHz 0.013% Using Fluke 6½ DMM 8846A
by Direct Method
*Measurement Capability is expressed as an uncertainty (+/-) at confidence probability of 95%.
7
SCOPE OF ACCREDITATIONMEASURE
www.eltelindustries.comELTEL INDUSTRIESCALIBRATION LABORATORY: Plot No.39, KIADB Industrial Area, Veerapura, Doddaballapur, Bengaluru – 561 203. INDIA.TEL: 91-80-27630366, 27630367, 27630368, +91-9686693047, +91-9686693048 FAX: 91-80-27630351 EMAIL: [email protected]
■ CHENNAI: 044-24339075 ■ GURGAON: 0124-2460619, 093115 42530 ■ MUMBAI: 022-21713579, 09325885244■ KOLKATA: 033-24765536, 09830067236, 09331094257 ■ VADODARA: 09327757574
Eltel Industries' state-of-the art calibration technology will cover almost all electrical parameters related to the
power industry. These standards are developed in our R&D Centre under the technical guidance of our expert
Canadian consultant Mr. Oleh Iwanusiw. The Calibration Lab is staffed by a highly experienced team with a
strong technical background. Our goal is to provide our customers with quick and timely support - talk to us
about any questions or concerns regarding our calibration services.
Eltel Industries, established in 1983, is a market leader in the manufacturing and development of test instruments
for electrical power industries and utilities. Customers in over 50 countries rely on Eltel's original design technology,
global accreditation and timely customer support, making Eltel a premier source for test instruments and
calibration services that are renowned for accuracy and reliability. Based in India, Eltel's experienced team looks
to optimize innovation and support, building strong and lasting relationships within the global industry.