March 2003 MX100 Regional Training MX100 Introduction

Transcript of MX100

Page 1: MX100

March 2003 MX100 Regional Training

MX100 Introduction

Page 2: MX100

March 2003 MX100 Regional Training

Product LOGO

Page 3: MX100

March 2003 MX100 Regional Training

Base PlateDifferent size for 1 to 6 modules.

MX100 Hardware Components

Main ModuleI/O Modules

Page 4: MX100

March 2003 MX100 Regional Training

Compact flash memory card slot for data backup

Ethernet100-Base-TX,10Base-T

Auto-switch

Dip SWChange operating mode

Operating Mode indicator

Data acquisition engine controlling up to 6 I/o modules in one system.

MX100 Main Module

Page 5: MX100

March 2003 MX100 Regional Training

I/O Module

4chHigh-speeduniversal inputmodule

10chMedium-speeduniversal inputmodule

10chHigh-speeddigital inputmodule

10chdigital outputmodule

Fastest measurement interval : 10ms

In of case TC/RTD, fastest measurement interval is 50 ms

Input : DCV/TC/RTD/DI

Fastest measurementinterval : 100ms Input : DCV/TC/RTD/DI

Fastest measurement

Interval : 10ms

Input : DI

Output interval :100msOutput : SPST relay (make contact)

Page 6: MX100

March 2003 MX100 Regional Training

MX100 Features

PC Font-end System allowing Flexible Construction High Speed & Multi-channel Measurement

4ch module with 10msec measurement interval 10ch module with 100msec measurement interval Scalable from 4 channels to hundreds channels 3 individual sampling speed can run in one system

High Withstand Voltage (Reinforced Insulation) 3700Vrms(1minute), 600Vrms/Vdc(working voltage)

between input terminal and case

Data Protection Compact flash card for back-up the data while communication down

Open Architecture, Others Modular construction 100Base-TX Ethernet standard Disconnect-able terminal, external screw terminal

Page 7: MX100

March 2003 MX100 Regional Training

100Base-TX

PC Front-end

To Network

Up to 20 units with MXLOGGER- 24ch/10msec- 300ch/100msec- 1200ch/1sec

Base plate

Main module with Ethernet, Compact flash card slot

Input/outputmodule

Page 8: MX100

March 2003 MX100 Regional Training

Scalable

From 1 module model to 6 module model can be Configured according to measurement channels

Page 9: MX100

March 2003 MX100 Regional Training

Multi Measurement Interval

100msec100msec10msec10msec 10sec10sec

3 individual sampling speed in one system

Setting example

Measurement intervals are set separately for each module.

Page 10: MX100

March 2003 MX100 Regional Training

CH1CH2

….

.

CH(n)

CH(n-1)

V12 * V1

Vmax=600Vrms/Vdc from groundin case of 1 system.

Module1

Module(n/10)

CH10

Vmax=600Vrms/Vdc between modules

CH(n-9)

- In case of 10ch module, 150VACrms(50/60Hz) is a maximum noise

voltage between channels in one module. And, the voltage between channels in one module is also restricted by IEC1010 6.3.

- In case of 4ch module, 250Vrms/Vdc is a maximum voltage between

channels in one module

n=600/V1

Common Mode Voltage Performance(Double Insulation)

n * V1

….

.

Page 11: MX100

March 2003 MX100 Regional Training

Common Mode Voltage Performance(Double Insulation)

Comparison table between Darwin and MX100

V1, V3 V2

10ms AI (4ch)

Allowable Common mode Voltage

600Vrms/Vdc 250Vrms/Vdc

Test Voltage (1min) 3700Vrms,50/60Hz

2300Vrms,50/60Hz

100ms AI (10ch) Allowable Common mode Voltage

600Vrms/Vdc 120Vrms/Vdc(SELV 250VACrms noise voltage, 50/60Hz)

Test Voltage (1min) 3700Vrms, 50/60Hz 1000Vrms, 50/60Hz

Darwin Allowable Common mode Voltage

160Vrms/Vdc(SELV 250VACrms noise voltage, 50/60Hz)

120Vrms/Vdc(SELV 150VACrms noise voltage, 50/60Hz)

Test Voltage (1min) 1500Vrms, 50/60Hz 1000Vrms, 50/60Hz

Aモジュール

Bモジュール

V1

V2

V3

Module A

Module B

V1

V2

V3

Page 12: MX100

March 2003 MX100 Regional Training

Technical Resource

High breakdown voltage solid state relay

High breakdown voltage solid state relay •3 individual sampling

interval in one system•100 Base-TX standard•Compact flash standard

•3 individual sampling interval in one system•100 Base-TX standard•Compact flash standard

•Measurement of true parallel multi-channel•CH Synchronizing

•Measurement of true parallel multi-channel•CH Synchronizing

Iso.

SCC

Iso.

SCC

Iso.

SCC

Iso.

SCC

ASIC

SCC

ASIC

ASIC

CPUEthernet

ROM RAM

Power

CF

コ ン ト ロ ー ル ユ ニ ッ ト10ch/100ms AI4ch/10ms AI

3700V withstanding transformer

Control unit10ch/100msec AI4ch/10msec AI

High reliable serial bus with high speed simultaneous data transmission

High reliable serial bus with high speed simultaneous data transmission

Page 13: MX100

March 2003 MX100 Regional Training

Data Back-up with CF Card

Support up to 2G bytes card

Start data storage at communication error Cable error

PC power fail, hung-up

Others

Re-start data transfer to PC automatically after the communication recovers

Communication True

Fail

True

File storage PC HD File A

MX CFFile B

PC HDFile C

Page 14: MX100

March 2003 MX100 Regional Training

Data Back-up with CF Card

number ofchannels

measurementinterval

32M 128M 512M

10ms approx. 2 hours approx. 9 hours approx. 36 hours

100ms approx. 21 hours approx. 3.5 days approx. 15 days

500ms approx. 4.5 days approx. 18.5 days approx. 75.5 days

2s approx. 18 days approx. 75.5 days approx. 303 days

10ms approx. 54 minutes approx. 3.5 hours approx. 15 hours

100ms approx. 9 hours approx. 37 hours approx. 6 days

500ms approx. 45 hours approx. 7.5 days approx. 31.5 days

2s approx. 7.5 days approx. 31.5 days approx. 126 days

10ms approx. 18 minutes approx. 75 minutes approx. 5 hours

100ms approx. 3.5 hours approx. 15 hours approx. 2.5 days

500ms approx. 18 hours approx. 3 days approx. 12.5 days

2s approx. 3 days approx. 12.5 days approx. 50 days

60ch

10ch

24ch

Data Storage length

Page 15: MX100

March 2003 MX100 Regional Training

Disconnect-able Terminal

Disconnect-able!!

Reduce re-wiring time when changing test- target and/or calibration.

Page 16: MX100

March 2003 MX100 Regional Training

External Connectivity

- Screw terminal- Better RJC uniformity

Screw terminal can be used only for 10ch AI module and 10ch DI module.

Page 17: MX100

March 2003 MX100 Regional Training

Others

- Connector cover - DIN rail mounting

Page 18: MX100

March 2003 MX100 Regional Training

Basic specifications

Number of modules, units: Up to 6 modules / 1 main module

(10ms 24 ch, 100ms 60 ch/unit)

Up to 20 units connectable through MX100 enhanced software

Filter: Time constant=Measurement period x N,

N=5,10,20,25,40,50,100

Selectable N number depends on measurement period.

Interface: 100 Base-TX

Compact flash slot: Type II x 1, Specially designed for memory card

Alarm (main module): 2 levels/ch

Calculation (main module): Difference, scaling

Main Module

Page 19: MX100

March 2003 MX100 Regional Training

Basic specifications

10 ch DI 10 ch DONumber of channels 10 ch 10 chInput and output types Non-voltage contact/TTL O.C/ SPST relay Level(5V logic)Measurement/output period minimum 10 ms minimum100 ms

Digital input/output module

4 ch high-speed module 10 ch scanner moduleNumber of channels 4 ch 10 chFastest measuring period 10 ms (50 ms for TC/RTD) 100 msMeasurement period Up to three types of intervals per system (on a module basis) 10, 50, 100, 200, 500ms, 1, 2, 5, 10, 20, 30, 60s Input ranges DCV/TC/RTD/DI DCV/TC/RTD/DI

DCV : 20mV, 60mV, 200mV, 2V, 6V, 20V, 100V TC : R,S,B,K,E,J,T,L,U,N,W,KpvsAu7Fe

RTD : Pt100, Pt50, NI100, NI120, Cu10 etc. DI : Non-voltage contact / Level(5V logic)Integration time: 1.67ms, 16.7ms, 20ms, 36.67ms, 100ms, 200ms Determined by the measurement periodMeasurement accuracy Integration time 16.7ms or longer 0.05% of rdg. + 5digits @2V rangeWithstanding voltage Between input terminal and case 3700VAC(50/60Hz) for 1 min. 3700VAC(50/60Hz) for 1 min. Between channels in one module 2300VAC(50/60Hz) for 1 min. 1000VAC(50/60Hz) for 1 min. (RTD also isolated) (b terminal common)

Analog input module

Page 20: MX100

March 2003 MX100 Regional Training

  MX100   DA100 Aims

Alarm

Shared by the main unit and PC softwareMain unit: 2 levels/channel

Upper/lower limits, upper/lower limits of difference

PC software: Implements by combining computation and command DORate-of-change alarm implementable

<>

Completely done on the main unit4 levels/channelUpper/lower limits, upper/lower limits of differenceRate-of-change alarm

Flexible alarm system implementableUsing the resources of the computation channels

Computation function

Shared by the main unit and PC softwareMain unit: Difference computation, scaling,

software filterPC software: Computation function provided as a

standard function

>

Completely done on the main unitDifference, scaling, moving average

 

Optional computation

function

Provided as a standard function. Darwin-/M1-level computation possible by the PC software. <>

Completely done on the main unit

Operation expressions easier to understand・ Constant description・ Total number of characters (40 → 250)・ C-language-like operator

Report function None. Use of the Excel macro, etc. < Provided as an option of /M3

Communications function

Ethernet only.Initial setup simplified such as automatic detection, automatic setup of IP address, etc.Binary-only format

<>

Ethernet, GP-IB, RS232, RS485ASCII command, binary/ASCII data

Simple setupHigh-speed setupDevelopment of self-made program supported by APIReduced number of communications types

Maintenance Update through the CF card slot, backing up function when communications disconnected, etc. > None Easy serviceability

Differences between MX100 and DA100 (2)

Page 21: MX100

March 2003 MX100 Regional Training

  MX100 DA100 Aims

System configuration

- PC-Base plate-Control unit-I/O Module

>

- PC-Basic/enhanced main unit-Subunit-I/O module-Communications module

Simple configuration covering a wide range of channels

Module types 10msAI,100msAI,DI,DO <

10ch20ch30ch UniversalmV/TCSingle-phase/three-phase power monitor120ohm /350ohm NDIS distortionDI-input-dedicated, mA inputPulse inputCurrent/voltage analog outputCommunications

Reducing the module types.Considering the real effects of each module.

Measurement cycle Maximum speed of 10 msMulti-interval of 3 types >>

Maximum speed of 500 msSynchronized with the cycle of the slowest module

High-speed measurementCoexistence of high speed and high stability

Withstand voltage 3700 V >> 1500 V Cell, electrolytic cell

Number of input points

60 channels/unit1200 channels/system <>

60 channels/subunit300 channels at the maximumMore channels connectable with the DAQLOGGER

Multi-channel measurement

Differences between MX100 and DA100 (1)

Page 22: MX100

March 2003 MX100 Regional Training

MX100 Software Concept

MX Standard Software- Ready to run control software

-MX100 broadcast search (UDP) and Automatic module/controller detection-Always monitoring, once connection is made, even in background-All hardware options configurable via MXStandard

-Advanced Data logging -Independently log up to three scan groups -Record/log interval to log every N scans -Manual and Automatic start and stop conditions

-Advanced viewer -One to Four independent Viewer areas -”Mark” comment on live data, stored into logfile -Parallel cursors on

-Data Export-Excel, ASCII, Lotus

Page 23: MX100

March 2003 MX100 Regional Training

MX100 Software ConceptMX Additional Software -Standalone Viewer

-View and Analyze recorded data-Cursor on all scan groups in parallel-Statistics or export data on selected regions

-MX Calibrator with wizards -Independently log up to three scan groups -Record/log interval to log every N scans -Manual and Automatic start and stop conditions

-Programming - API -Programmatically automate any MX measurement -Use C/C++, Visual Basic, or LabVIEW -DLL, VI, OPC support

Page 24: MX100

March 2003 MX100 Regional Training

Software Options

Basic Specifications Features

Dedicated Software

Standard - One-to-one connection with the MX

(Up to 60 channels per unit)

- Setup, monitoring

Logging, redisplay

- Ready for multi-interval- Computation- Relay Output

Enhanced - Connected with two or more number of MX units

- Setup, monitoring

Logging, redisplay

Monitor server

- Ready for multi-interval

- Computation (between the units)

- Relay output - Synchronized data

processing among two or more number of MX units

API

LabView

Functions for setup and data sampling

Saving the man-hours of the users to develop self-made software

Page 25: MX100

March 2003 MX100 Regional Training

MX100 standard software Useful features : Distributed data acquisition

M.N T.F

Multi MX connected under same segment network is detected automatically.

Network configuration menu

Dedicated LAN

Page 26: MX100

March 2003 MX100 Regional Training

MX100 standard software Useful features : Manual DO during monitoring/recording

Page 27: MX100

March 2003 MX100 Regional Training

Combination with DARWIN/DAQSTATION

MXLOGGER

DAQLOGGER

MXLOGGERMonitor Server

MXLOGGERMonitor Server

Page 28: MX100

March 2003 MX100 Regional Training

Logo of DAQWORX

+

Page 29: MX100

March 2003 MX100 Regional Training

Network

DAQWORX Data Highway

I/F

OPC

DAQLOGGERDAQEXPLORER DAQ32+DAQOPC

ADDObserver ADDMultiInTouchVDS

DAQWORX R1

MX-Log

GateDXP GateWT

ADDTRigger

GateOPC

GateEye GateMODBUS

DAQWORX

Page 30: MX100

March 2003 MX100 Regional Training

DAQWORX Roadmap

PC Software

DAQWORX R2Feb

2004

AddDataManagerAddEventAddWebGateFA-M3

Improved installerMore value-add

DAQWORX R3Mid

2004

AddReport+α

Universal Launcher

DAQWORX R1

MX100 loggerAddTriggerGateWTGateEyeGateDX-PGateOPCGateMODBUS

Suite (1 CD)

Jun 2003

Today