MWS Modular Wiring System TC-5LT T Cable with DALI Control ...€¦ · fixture. Compatible MWS...

1
TC-5LT T CABLE Modular Wiring System MWS ® Catalog # Type Date Project Comments Prepared by DESIGN FEATURES • UL Listed under Standard 183 for make or break under load. • Meets requirements of Article 604 of the National Electrical Code. • MWS components assembled with 12 AWG conductors rated at 20 amperes with full size ground wire. • Copper conductors are THHN insulated wire rated 90°C. • Galvanized steel exterior with integral keying for voltage and amperage. • Valox 365 constructed contact housings are approved for environmental air plenums. • Allows downstream feeding of circuits to another electrical component or fixture. • Cable end supplied with 1/2” connector with locknut and 6” pre-stripped leads. All unused outlets require a MWS dust cover. MWS ST, SP, SD, CT and TC are shipped with one dust cover attached. MWS-5LT, Modular Wiring Systems with DALI Control, provides low cost installation of both power for lighting and Class 1 control wiring for use with Fifth Light DALI systems. Using modular components that plug together, MWS-5LT can be installed in a fraction of the time of hardwiring both lighting and control. Plus, MWS-5LT offers the advantage of relocating fixtures and DALI control devices for future renovations. The MWS T Cable with DALI Control (TC-5LT) feeds power and control wiring to wall or ceiling fixtures while feeding downstream to another fixture. Compatible MWS Extender Cables (EC) are used connect either end of the TC-5LT. See the Extender Cable specification sheet for compat- ible models. MWS Extender Cables feed power to each T Cable. DESCRIPTION PS510004EN 2015-04-06 13:41:56 All electrical boxes, conduit, connections and switches by others. Install dust covers on unused open ends. Scale is exaggerated on fixtures and MWS system applications. S Y S T E M S C E R T I F I E D MWS AUTOCAD DRAFTING MWS offers AutoCAD drafting to layout MWS, providing the contractor with additional benefits. MWS design layout time is reduced. Bills of material are computer-generated guaranteeing accuracy. MWS drawing symbols and details standardized. Layouts are available on CD or e-mail. To utilize this service and for additional information, contact the MWS Sales Department (888) 487-4887. Side Top Front 2-1/4" [57mm] 5-5/16" [136mm] DIMENSIONAL DATA Extender Cable T Cable Extender Cable SYSTEM VIEW (not to scale) SAMPLE NUMBER: 27TC12/4G095LT Component TC=T Cable TC Voltage 12=120V 27=277V Conductors and Size 12/4G=#12, 4 Conductors Plus Ground Cable Length (Feet) 01=1' 09=9' 15=15' Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Options 5LT ORDERING INFORMATION Cable Unit Standard Length Wt. Qty./Carton 1’ 1.0 lbs. 12 9’ 3.5 lbs. 8 15’ 5.0 lbs. 6 SHIPPING DATA Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Specifications and dimensions subject to change without notice. Eaton’s Cooper Lighting Business 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting

Transcript of MWS Modular Wiring System TC-5LT T Cable with DALI Control ...€¦ · fixture. Compatible MWS...

Page 1: MWS Modular Wiring System TC-5LT T Cable with DALI Control ...€¦ · fixture. Compatible MWS Extender Cables (EC) are used connect either end of the TC-5LT. See the Extender Cable

TC-5LT

T CABLEModular Wiring System

MWS®

Catalog # Type

Date

Project

Comments

Prepared by

DESIGN FEATURES

• UL Listed under Standard 183 for make or break under load.

• Meets requirements of Article 604 of the National Electrical Code.

• MWS components assembled with 12 AWG conductors rated at 20 amperes with full size ground wire.

• Copper conductors are THHN insulated wire rated 90°C.

• Galvanized steel exterior with integral keying for voltage and amperage.

• Valox 365 constructed contact housings are approved for environmental air plenums.

• Allows downstream feeding of circuits to another electrical component or fixture.

• Cable end supplied with 1/2” connector with locknut and 6” pre-stripped leads.

All unused outlets require a MWS dust cover. MWS ST, SP, SD, CT and TC are shipped with one dust cover attached.

MWS-5LT, Modular Wiring Systems with DALI Control, provides low cost installation of both power for lighting and Class 1 control wiring for use with Fifth Light DALI systems. Using modular components that plug together, MWS-5LT can be installed in a fraction of the time of hardwiring both lighting and control. Plus, MWS-5LT offers the advantage of relocating fixtures and DALI control devices for future renovations.

The MWS T Cable with DALI Control (TC-5LT) feeds power and control wiring to wall or ceiling fixtures while feeding downstream to another fixture. Compatible MWS Extender Cables (EC) are used connect either end of the TC-5LT. See the Extender Cable specification sheet for compat-ible models.

MWS Extender Cables feed power to each T Cable.

DESCRIPTION

PS510004EN2015-04-06 13:41:56

All electrical boxes, conduit, connections and switches by others.

Install dust covers on unused open ends.

Scale is exaggerated on fixtures and MWS system applications.

S

YSTEMS

C

E RT I F I E

D

MWS AUTOCAD DRAFTINGMWS offers AutoCAD drafting to layout MWS, providing the contractor with additional benefits.

MWS design layout time is reduced.

Bills of material are computer-generated guaranteeing accuracy.

MWS drawing symbols and detailsstandardized.

Layouts are available on CD or e-mail.

To utilize this service and for additionalinformation, contact the MWS Sales Department (888) 487-4887.

Side

Top

Front

2-1/4"[57mm]

5-5/16"[136mm]

DIMENSIONAL DATA

Extender Cable T Cable Extender Cable

SYSTEM VIEW (not to scale)

SAMPLE NUMBER: 2 7 T C 1 2 /4 G 0 9 5 L T

ComponentTC=T Cable

TC

Voltage12=120V27=277V

Conductors and Size12/4G=#12, 4 Conductors Plus Ground

Cable Length (Feet)01=1'09=9'15=15'

Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representativefor availability and ordering information.

Options5LT

ORDERING INFORMATION

Cable Unit Standard

Length Wt. Qty./Carton

1’ 1.0 lbs. 12

9’ 3.5 lbs. 8

15’ 5.0 lbs. 6

SHIPPING DATA

Eaton1000 Eaton BoulevardCleveland, OH 44122United StatesEaton.com

Specifications and dimensions subject to change without notice.