Multi-line building cable & pipe entry system EK 349...2-line building cable & pipe entry system...
Transcript of Multi-line building cable & pipe entry system EK 349...2-line building cable & pipe entry system...
Langmatz GmbH Am Gschwend 10 Telephone +49 88 21 920-0 E-mail [email protected] Garmisch-Partenkirchen | Germany Fax +49 88 21 920-159 Website www.langmatz.de
12
for buildings with basements | Dry installation2-line building cable & pipe entry system
Advantages
Multi-line building cable & pipe entry system EK 349
• Highly � exible sealing systems bridge largediameter ranges, only one sealing set is required
• When one utility line is retro� tted, the second seal remains untouched • Utility lines can be independently con� gured and exchanged • EK 349 is supplied with torque-limiting bolts • The ring seal directly seals in the unit to the exterior wall. Further sealing for the core drill
hole is not required • The sealing system for media cables consists of conical, permanently elastic
sealing rings. This material ideally adapts to non-round cables and uneven surfaces • The supply cables are sealed independently from one another.
When con� guring each of the supply cables, only: - two bolts are loosened | - the cable or pipe is inserted | - the bolts are tightened
EK 349
Area of application A 2-line utility services connection combines supply lines for • Electricity or water • Telecommunication and optical-� bre cable
in a compact system. Just one operation and one route and the house is connected
Sealing system for the inside of the wall
Langmatz GmbH Am Gschwend 10 Telephone +49 88 21 920-0 E-mail [email protected] Garmisch-Partenkirchen | Germany Fax +49 88 21 920-159 Website www.langmatz.de
Subj
ect t
o ch
ange
with
out n
otice
| As
of 0
4-20
17
13
Connection options • Water: Pipe diameter 1"
or
• Electricity: Cable diameter 26 - 34 mm (max. 4x70 mm2 single-wire sector-shaped conductors)
• Telecommunications 3 cables, diameter 7 - 15 mmThe individual cables can be retroactively con� gured; the seals are not required to be replaced in the process.3 optical-� bre cables, diameter 7 - 15 mm
Shear nuts and bolts
Installation The shear bolts for the electricity and water utility lines are torque-limiting and pre-installed.This way, installation is not only fast and easy, but safe as well.
Accessories • Casing pipe roughened, as place holder in the wall:
Diameter: 90 mm | PVC materialLength: 250 mm / 300 mm / 400 mm
• Other wall diameters available on request
Technical data • Core drill hole: 90 mm diameter
• Gas- and water-pressure-tight up to 1 bar
• Not suitable for � ligree walls
• Possible wall thicknesses: 50 - 460 mm
• Seals can be variably arranged
• The seals are able to seal large diameter ranges with a single sealing insert (e.g. 26 - 34 mm, 3x telecommunication cables, 7 - 15 mm)