FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 1/24
This document is available at www.alma-alma.fr
OPERATING MANUAL
MU 7038 EN C
GRAVICOMPT MANIFOLD
C 2015/09/08 Volume conversion [MDV399] DSM XS
B 2015/04/13 Creation DSM AH
Issue Date Nature of modifications Written by Approved by
Rel
evan
t sof
twar
e 3
48+
v2.0
2.X
X
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 2/24
This document is available at www.alma-alma.fr
CONTENTS
1 GENERAL PRESENTATION AND DESCRIPTION: ...................................................................................4
2 OPERATING RECOMMENDATIONS: ...................................................................................................5
3 OPERATION MODES OF THE INDICATOR DEVICE: ...............................................................................5
4 DRIVER MODE: .................................................................................................................................6
4.1 Menu DELIVERY .......................................................................................................................6
4.1.1 Delivery in preset mode ................................................................................................................................ 7
4.1.2 Delivery in FREE mode .................................................................................................................................. 7
4.1.3 Delivery in not-counted mode ...................................................................................................................... 7
4.2 Menu PRINT ............................................................................................................................8
4.3 Menu DISPLAY .........................................................................................................................9
4.3.1 Sub-menu TOTALISER ................................................................................................................................... 9
4.3.2 Sub-menu MEMORIZATION .......................................................................................................................... 9
4.4 Menu MAINTENANCE ............................................................................................................ 10
4.5 List of alarms ......................................................................................................................... 11
5 SUPERVISOR MODE: ....................................................................................................................... 12
5.1 Menu CALIBRATION ............................................................................................................... 12
5.1.1 Sub-menu ENTER GAUGE VOLUME ............................................................................................................ 12
5.1.2 Sub-menu GAUGE FILLING .......................................................................................................................... 13
5.2 Menu PRODUCTS SETTING ..................................................................................................... 13
5.3 Menu VEHICLE ....................................................................................................................... 13
5.4 Menu SETTINGS ..................................................................................................................... 13
5.4.1 Sub-menu VOLUMES SETTINGS .................................................................................................................. 13
5.4.2 Sub-menu TIMING SETTINGS ...................................................................................................................... 14
5.4.3 Sub-menu DEFAULT SETTINGS .................................................................................................................... 15
5.5 Menu TIME ADJUSTMENT ...................................................................................................... 15
5.6 Menu LANGUAGE .................................................................................................................. 15
5.7 Menu PARAMETERS ............................................................................................................... 15
5.7.1 Sub-menu CONFIGURATION ....................................................................................................................... 15
5.7.2 Sub-menu measuring system EMA ............................................................................................................. 16
6 METROLOGICAl MODE: .................................................................................................................. 17
6.1 Menu INDICATOR REFERENCE ................................................................................................ 17
6.2 Menu CONFIGURATION.......................................................................................................... 17
6.2.1 Sub-menu COMPARTMENTS....................................................................................................................... 17
6.2.2 Sub -menu UNIT AND ACCURACY ............................................................................................................... 18
6.2.3 Sub-menu CONVERSION ............................................................................................................................. 19
6.3 Menu measuring system EMA ................................................................................................ 19
6.3.1 Sub-menu METER COEFFICIENT .................................................................................................................. 20
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 3/24
This document is available at www.alma-alma.fr
6.3.2 Sub-menu CORRECTION ............................................................................................................................. 20
6.3.3 Sub-menu METER FLOWRATES ................................................................................................................... 20
6.3.4 Sub-menu VOLUMES .................................................................................................................................. 20
6.3.5 Sub-menu TEMPERATURE .......................................................................................................................... 21
6.3.6 Sub-menu DETECTOR .................................................................................................................................. 21
6.4 Menu DATE AND TIME ........................................................................................................... 21
ANNEXE ................................................................................................................................................. 22
RELATED DOCUMENTS ........................................................................................................................... 24
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 4/24
This document is available at www.alma-alma.fr
1 GENERAL PRESENTATION AND DESCRIPTION:
The GRAVICOMPT MANIFOLD is an interruptible measuring system. It is intended for delivery of liquids other than water. Liquids flow from each of the compartments of a road tanker connected to the manifold.
The GRAVICOMPT MANIFOLD measuring system is fitted with: � A turbine meter � A MICROCOMPT+ electronic calculator-indicator device � A differential pressure sensor � A gas detection sensor located upstream of the turbine meter � A transfer valve which regulates flow � Air-operated gates connecting each compartment with the manifold � A non-return vent valve to ensure the manifold fills and empties properly � A printer (option). The calculator-indicator MICROCOMPT+ allows to display: � Either volume at metering conditions – Vm � Or volume converted to base conditions – Vb.
It is designed to measure volumes of liquid by gravity (pre-set or not). An option takes into account the temperature of liquid.
The calculator-indicator controls one manifold connected to up to 10 compartments with a maximum of 16 products which names are configurable
In option, it may print delivery tickets, internal totaliser, parameters, and events diary
NOTE: Information printed on the printer has no metrological value. Only the values displayed by the main indicating device providing proof.
Presentation of the MICROCOMPT+ calculator-indicator:
Sealed cup protecting access
to metrological functions
SUPERVISOR magnetic key to access configuration and calibration menu
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 5/24
This document is available at www.alma-alma.fr
Buttons function:
The MICROCOMPT+ calculator-indicator manages measuring operation and computerizes the measuring system defaults.
2 OPERATING RECOMMENDATIONS:
Before using a GRAVICOMPT MANIFOLD measuring system, the operator must ensure that the following conditions have been met:
� The piping linking each compartment and the transfer valve must have a minimum pitching of 3%. The vehicle on which the measuring system is installed must be fitted with a device to ensure it is horizontal
� The end-of-counting probe is placed so that it can detect the vacuity of the collector on the smallest free surface.
3 OPERATION MODES OF THE INDICATOR DEVICE:
Driver mode This is the normal using mode in exploitation. Refer to DRIVER MODE
Supervisor mode To access the supervisor mode, the magnetic key must be put at the right of the MICROCOMPT display. This mode is used to set the measuring system and to access the calibration menu. Refer to SUPERVISOR MODE for setup.
Metrological mode To access the METROLOGICAL mode, the MICROCOMPT has to be unsealed. Only an authorized person can remove the seal. This mode allows setting all metrological parameters. It’s done at the putting into use of the measuring system and sometimes during metrological controls. Refer to METROLOGICAL MODE for configuration.
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 6/24
This document is available at www.alma-alma.fr
4 DRIVER MODE:
4.1 Menu DELIVERY
A delivery includes several operations. An operation includes the following stages:
• Selection of the compartment • Selection of the product • Selection of the distribution mode: preset, free or not counted.
At the end of an operation, press MENU to start a new operation.
At the end of the delivery, choose the menu END DELIVERY? Validate with OK.
MODE�PRESET
MODE�FREE
PRODUCT�GO
PRODUCT�SP95
END DELIVERY?
DELIVERY XC1 / -- -- -- -- --
MODE�NOT COUNTED
Place the delivery ticket in the printer before validating
>DELIVERY TICKET? >ADD PAPER >PRINTING FINISHEDPRINTING...
Remove the ticket
During the measurement, some information may be displayed by pressing MENU:
Unit: m3/h or L/minINSTANT. FLOW
PRODUCT HEIGHT
471 kg/mm/min /h
PRODUCT HEIGHT
INSTANT. FLOW HF
59,3 L kg/m3
/min /h
with active optionINSTANTANEOUS TEMP.
+18,3 kg/°C/min /h
INSTANTANEOUS TEMP.
OK
STOP
DELIVERY
DISPLAY
MAINTENANCE
MENU
Back to normal display is automatic.
DON’T PRESS STOP PUSHBUTTON.
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 7/24
This document is available at www.alma-alma.fr
4.1.1 Delivery in preset mode
Validate the delivery mode MODE�PRESET and set the volume. Pressing OK makes the preset unloading begin. If the preset volume is lower than the authorised volume, the measurement will be invalidated at the end of the operation; it will be displayed alternately with dashes: ‘-- -- --’.
1000 LEND OPERATION
1000 LCONTINUE OPERATION
1000 LOPERATION FINISHED
MODE�PRESET 000000 LENTER PRESET
1000 LC1/ GO / START
0 LFILLING
256 LC1/ GO /PRESET
1000 LDRAIN IN PROGRESS
256 LSTOP OPERATION
1000 LDRAIN IN PROGRESS
IF OPERATION STOPPED
4.1.2 Delivery in FREE mode
Validate the distribution mode MODE�FREE. Pressing OK makes the unloading begin in order to empty the compartment. Pressing the STOP button stops the unloading.
MODE�FREE 0 LC1/ GO / START
256 LC1/ GO /FREE
2259 LDRAIN IN PROGRESS
2259 LOPERATION FINISHED
256 LSTOP OPERATION
256 LEND OPERATION
256 LCONTINUE OPERATION
256 LC1/ GO / START
256 LDRAIN IN PROGRESS
256 LOPERATION FINISHED
0 LFILLING
4.1.3 Delivery in not-counted mode
Validate the distribution mode MODE�NOT COUNTED. The unloaded volume is not verified by the measuring system (measuring container). This delivery mode is used when the end of counting probe is out of order).
MODE�NOT COUNTED ENTER VOLUME 00000 LENTER VOLUME
2300 LEND DELIVERY?
- - - - - - LEND DELIVERY?
Remember to follow any regulations in force
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 8/24
This document is available at www.alma-alma.fr
4.2 Menu PRINT
For printing a daily summary.
SUMMARY 19.07DATE (DD.MM)
DELIVERY TICKET >ADD PAPER >PRINTING FINISHED
The delivery ticket of the last measurement is printed when this item is chosen.
TOTALISER >ADD PAPER
For printing the general totaliser.
PARAMETERS >ADD PAPER
For printing the metrological parameters and the setting value stored in the calculator device.
EVENTS RECORDED 02.07.15DATE (DD.MM.YY)
>ADD PAPER
>ADD PAPER
PRINTING...
PRINTING...
PRINTING...
PRINTING...
PRINTING...
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 9/24
This document is available at www.alma-alma.fr
4.3 Menu DISPLAY
4.3.1 Sub-menu TOTALISER
Visualization of the general totaliser.
00011 LINDEX TOTAL 00011548
548 LINDEX TOTAL 00011548
General totaliser displayed in liters.
4.3.2 Sub-menu MEMORIZATION
This menu is available in stand-by mode or during an intermediate stop. It allows the proofreading of all the measurement results stored by the GRAVICOMPT MANIFOLD. That can be done in two ways: LIST: Display all the measurement details recorded, from the newest to the oldest, sorted by day then by measurement number. SELECTION: Display a specific measurement by selecting the day number For each measurement, are displayed: the number and the name of the product, the measured volume, temperature and density with active options. MEMORIZATION LIST
SELECTION
000217INDICATOR REFERENCE
202DAY NUMBER
003MEASUREMENT NUMBER
000217INDICATOR REFERENCE
202DAY NUMBER
003MEASUREMENT NUMBER
001000 LCOMPARTMENT X
750.0 kg/m3
PRODUCT X/ XXX
000990 LCOMPARTMENT X
Vm
Vb
+22.9 °CMEAN TEMPERATURE
002MEASUREMENT NUMBER
000400 LCOMPARTMENT X
750.0 kg/m3
PRODUCT X/ XXX
Vm
If conversion is ON
If temperature is ON
750.0 kg/m3
PRODUCT X/ XXX
If conversion is ON
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 10/24
This document is available at www.alma-alma.fr
4.4 Menu MAINTENANCE
EMA/ECP (XX)MAINTENANCE
842 mmPRODUCT HEIGHT
Status of the end of counting probe which can be:DRY, WET or FAULT (out of order).
Instantaneous height of product in the compartiment (mm).
+21 °CINSTANTANEOUS TEMP.
Instantaneous temperature of the product in the compartment (°C).
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 11/24
This document is available at www.alma-alma.fr
4.5 List of alarms
Apparition of a default makes the pouring stop by closing the transfer valve. At the same time, the MICROCOMPT+ displays the associated alarm message. The operator must deal with the default and then validate the alarm.
BL
OC
KIN
GN
ON
BL
OC
KIN
G
MEMORY OVER LOADED Delivery diary is full
DISPLAY MEANING ACTION
MEMORY LOST (PILE)
MEMORY LOST
PROM DEFAULTRAM DEFAULT
EEPROM MEMORY LOST
Loss of saved memory
Delivery diary lost
Loss of software or resident integritySaved memory fault
Loss of metrological configuration
Substitution of the backup battery
Substitution of the AFSEC+ electronic card
TEMPERATURE FAULT
DISPLAY DEFAULT
Temperature determination failure
Problem with display card
TOTALISER LOST Loss of totaliser
If steady alarm, substitution of the display card
Substitution of the backup battery
Check the temperature probe status /If steady alarm, see a reparator for trouble shooting
LOW FLOW DEFAULT Low flowrate (less than 4m3/h)HIGH FLOW DEFAULT
PRINTER DEFAULTPOWER SUPPLY PROBLEM
ZERO FLOW DEFAULT
DATE AND TIME LOST
STOP OPERATION
High flowrate (greater than maximum flowrate)
No more communication with the printerPower outage during operation
Zero flow
Loss of date and time
Intentional interruption of discharge
Check the parameters / Reduce flowrate
Check the connection cable, on-off switch and fuseCheck the cause / Restore power supply
Check if the pulse transmitter is powered (red indicators)
Set date and time in supervisor mode (supervisor key)
Continue, stop or finish the operation
Check the hydraulic system (valve, strainer, nozzle…)
METERING PROBLEM
FLAP LEAK DEFAULT
Metering problem with the measuring device
Product leakage from a flap
Check if the pulse transmitter is powered (red indicators)
Check the flap
US
ER
Enter and exit the METRO mode / If steady alarm, substitution of the backup battery
Substitution of the AFSEC+ electronic cardSubstitution of the AFSEC+ electronic cardSubstitution of the AFSEC+ electronic card
RE
PA
IRE
R
If steady alarm, see a reparator for trouble shooting
DIARY DEFAULT Reset of the events diary Acknowledge the alarm, check the date in supervisor mode (supervisor key)
MANIFOLD NOT EMPTYThe manifold is not empty at the beginning of the
operationFollow the manifold release sequence
GAS DEFAULT Détection d’air en phase de grand débit
END DG DEFAULT End of pouring probe out of orderPRESSURE DEFAULT Pressure determination failure If steady alarm, see a reparator for trouble shooting
If steady alarm, see a reparator for trouble shooting
WATCHDOG DEFAULT Fault with display or power card or AFSEC+ cardSwitch on-off the MICROCOMPT+ /
If steady alarm, substitution of the faulty card
VOLUME CONVER DEFAULT Problem during volume conversion If steady alarm, substitution of the AFSEC+ electronic card
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 12/24
This document is available at www.alma-alma.fr
5 SUPERVISOR MODE:
MENU
STOP
OK
SETTINGS
VEHICULE (XX)
CALIBRATION / GAUGE
PRODUCTS SETTINGS
TIME ADJUSTMENT
LANGUAGE (XX)
PARAMETERS
5.1 Menu CALIBRATION
CALIBRATION / GAUGE ENTER GAUGE VOLUME
GAUGE FILLING
5.1.1 Sub-menu ENTER GAUGE VOLUME
This menu allows you to check the accuracy of the measuring system by calculating the measuring device error and the new corrected coefficient. First, use the GAUGE FILLING menu to calibrate the measuring system. Enter the volume read on the gauge and validate. The following information is then displayed: � The signed error in % � The coefficient revised as a function of the error � The average flow of the delivery
Each of these values is shown step by step and by pressing the green button OK. Then the product in the manifold is released.
00598.6 LENTER VOLUME (REF)
+00.17ERROR (PERCENT)
11.4892COEFFICIENT (P/L)
ENTER GAUGE VOLUME 47.3AVERAGE FLOWRATE
kg/m3
/h
00598.6 LENTER VOLUME (REF)
+00.17ERROR (PERCENT)
11.4892COEFFICIENT (P/L)
47.3AVERAGE FLOWRATE
L kg/m3
/min /h 34 LMANIFOLD DRAINING?
34 LRELEASE PRODUCT
34 LOPERATION FINISHED
After menu GAUGE FILLING
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 13/24
This document is available at www.alma-alma.fr
5.1.2 Sub-menu GAUGE FILLING
This menu is used for filling the gauge with keeping the manifold full of product. Use it the same way as the user mode; at the end of the operation, the manifold is not drained. At the end of the operation, the display returns to ENTER GAUGE VOLUME menu after pressing the green button OK. GAUGE FILLING MODE�PRESET 000000 L
ENTER PRESET
600 LOPERATION FINISHED
0 LCX/ SP95 / START
0 LFILLING
600 LCX/ SP95/ PRESET
PRODUCT�SP95 0 LC1 / -- -- -- -- --
5.2 Menu PRODUCTS SETTING
Definition of products. For the 5 first products, default names are proposed. To remove a product, enter blank space as name product. Maximum number of characters: 5
PRODUCTS SETTING 1CHOOSE PRODUCT
01/NAME (GO ) 01/NAME�GO
01/CORRECTION (XX) 01/CORRECTION�OFF
01/CORRECTION�ON
16CHOOSE PRODUCT
16/NAME ( ) 16/NAME�
16/CORRECTION (XX) 16/CORRECTION�OFF
16/CORRECTION�ON
5.3 Menu VEHICLE
Set the vehicle registry number on which the GRAVICOMPT MANIFOLD is installed. This number will be printed on delivery tickets, invoices…
VEHICLE (AA--000--AA) VEHICLE�AA--000--AA
5.4 Menu SETTINGS
5.4.1 Sub-menu VOLUMES SETTINGS
This menu allows setting the volume parameters: VOLUME LF�HF: Set the volume (in liters) beyond which the MICROCOMPT+ controls the high flowrate at the beginning of the measurement. Example: "0030" for 30 litres. VOLUME HF�LF: Set the volume (in liters) beyond which the MICROCOMPT+ controls the low flowrate at the end of a preset measurement when the end of counting probe is still wet.
VOLUMES SETTINGS 0 LVOLUME LF�HF
0000 LVOLUME LF�HF
10 LVOLUME HF�LF
0010 LVOLUME HF�LF
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 14/24
This document is available at www.alma-alma.fr
5.4.2 Sub-menu TIMING SETTINGS
This menu allows setting the duration parameters: OPENING INCREMENT(S): Set the command increment duration of the API adapter opening valve (in seconds). Minimal value: 0.03 second. Maximal value: 3.999 seconds. Default value: 0.070 second (70 millisecondes). OPENING RELAX.(S): Set the relaxation duration between two API adapter opening command increments (in seconds). Maximal value: 3.999 seconds. Default value: 1 second. CLOSING INCREMENT(S): Set the command increment duration of the API adapter closing valve (in seconds). Maximal value: 3.999 seconds. Default value: 0.070 second (70 millisecondes). CLOSING RELAX.(S): Set the relaxation duration between two API adapter closing command increments (in seconds). Maximal value: 3.999 seconds. Default value: 1 second. ANTI-VORTEX STOP(S): Set the API adapter closing duration after an ANTI-VORTEX breakdown. Minimal value: 5 seconds. Maximal value: 99 seconds. Default value: 5 seconds. MANIFOLD FILLING(S): Set the manifold filling duration (in seconds). Minimal value: 20 seconds. Maximal value: 59 seconds. Default value: 30 seconds. MANIFOLD DRAINING(S): Set the manifold draining duration (in seconds). Minimal value: 20 seconds. Maximal value: 59 seconds. Default value: 30 seconds. WET PROBE: Set the maximum duration before the end of counting probe become wet (in seconds). Minimal value: 20 seconds. Maximal value: 99 seconds. Default value: 10 seconds. TIMING SETTINGS 0.070
OPENING INCREMENT(S)
0.070OPENING INCREMENT(S)
1.000OPENING RELAX.(S)
1.000OPENING RELAX.(S)
0.070CLOSING INCREMENT(S)
0.070CLOSING INCREMENT(S)
1.000CLOSING RELAX.(S)
1.000CLOSING RELAX.(S)
5ANTI-VORTEX STOP(S)
05ANTI-VORTEX STOP(S)
30MANIFOLD FILLING(S)
30MANIFOLD FILLING(S)
30MANIFOLD DRAINING(S)
30MANIFOLD DRAINING(S)
10WET PROBE (S)
10WET PROBE (S)
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 15/24
This document is available at www.alma-alma.fr
5.4.3 Sub-menu DEFAULT SETTINGS
This menu allows setting the temperature and density default values when CONVERSION is ON.
DEFAULT SETTINGS +15.0 °CTEMPERATURE
+15.0 °CENTER TEMPERATURE
750.0 kg/m3
DENSITY
750.0 kg/m3
ENTER DENSITY
5.5 Menu TIME ADJUSTMENT
Date and time are set in METROLOGICAL mode. The hour may be adjusted (±2h) one time a day through this menu.
TIME ADJUSTMENT 14.41TIME (HH:MM)
e.g. 14.14 means 2:41 pm
5.6 Menu LANGUAGE
This menu is available if a translation catalogue has been uploaded in the MICROCOMPT+. The message “INCORRECT TRANSLATION CATALOG” appears in the event that no catalogue is uploaded.
LANGUAGE (XX) EN
FR
Choose the display language.
5.7 Menu PARAMETERS
This menu allows displaying the parameters set in METROLOGICAL MODE. See the related chapter for the meaning.
PARAMETERS 00000INDICATOR REFERENCE
CONFIGURATION
EMA
5.7.1 Sub-menu CONFIGURATION
See the METROLOGICAL MODE chapter for the meaning of each parameter.
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 16/24
This document is available at www.alma-alma.fr
CONFIGURATION Compartments managed by the GRAVICOMPT.
N° of the first compartment.
UNIT AND ACCURACY Unit of flowrate 123.4FLOWRATE UNIT
L kg/m3
/min /h
LOW FLOW HEIGHT XX mmC X/LF HEIGHT Height thresholds below
which the unloading is done in low flow.
XCOMPARTMENT NUMBER
XFIRST COMPARTMENT
XX mmC X/LF HEIGHT
5.7.2 Sub-menu measuring system EMA
See the METROLOGICAL MODE chapter for the meaning of each parameter.
EMA
200 LMINIMUM QUANTITY
DETECTOR (XX) Type of gaz detector on the manifold: ATEX (DG3001) or non-ATEX (DG3000).
24.0 LMANIFOLD VOLUME
5.0 LFIXED VOLUME
00.0000METER COEFFICIENT
Coefficient of the meter of the measuring system (in pulses/liter).
+0CORRECTION(THOUSAND)
SETTINGS VOLUMES SETTINGS
FLOW RATES SETTINGS 8.0MINIMUM FLOWRATE
L kg/m3
/h
80.0MAXIMUM FLOWRATE
L kg/m3
/h
18.0OBJECTIVE LOW FLOW
L kg/m3
/h
Correction factor per thousand (‰) of the measuring system for a measurement with high viscosity products.
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 17/24
This document is available at www.alma-alma.fr
6 METROLOGICAL MODE:
INDICATOR REFERENCE
DATE AND TIME
MENU
STOP
OK
CONFIGURATION
EMA
6.1 Menu INDICATOR REFERENCE
Set the GRAVICOMPT serial number (5 numeric values). 00000ENTER REFERENCE
00000INDICATOR REFERENCE
6.2 Menu CONFIGURATION
CONFIGURATION
UNIT AND ACCURACY
COMPARTMENTS
CONVERSION (XX)
6.2.1 Sub-menu COMPARTMENTS
This menu is to describe the compartments configuration. COMPARTMENT NUMBER: Set the compartments number depending on the measuring system (maximum 7 or 10). FIRST COMPARTMENT: Set the first compartment to determine which compartments will be useful. LOW FLOW HEIGHT: Set the compartment height threshold in mm. Below this threshold, the unloading will be done in low flow. The reference zero is the tapping of the differential pressure transmitter. (Example: set "00635" for a 635mm height from the tap point).
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 18/24
This document is available at www.alma-alma.fr
LOW FLOW HEIGHT 100 mmC X/LF HEIGHT
COMPARTMENTS 0COMPARTMENT NUMBER
0FIRST COMPARTMENT
01ENTER CPT. NUMBER
00100 mmENTER LF HEIGHT
100 mmC X/LF HEIGHT
00100 mmENTER LF HEIGHT
X = COMPARTMENT NUMBER
01ENTER COMPARTMENT
6.2.2 Sub -menu UNIT AND ACCURACY
Choose the flow rate unit which is displayed and printed.
UNIT AND ACCURACY
1234CHOSSE UNIT
L kg/m3
/min /h
123.4FLOWRATE UNIT
L kg/m3
/min /h 123.4CHOOSE UNIT
L kg/m3
/min /h
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 19/24
This document is available at www.alma-alma.fr
6.2.3 Sub-menu CONVERSION
CONVERSION (XX) CONVERSION�OFF
CONVERSION�ON
+15.0 °C
REFERENCE TEMP.
+15.0 °C
ENTER REFERENCE TEMP.
MAIN DISPLAY (XX) MAIN DISPLAY�VM
MAIN DISPLAY�VBASE
+15.0 °C
DENSITY TEMP. (REF)
+15.0 °C
DENSITY TEMP. (REF)
CONVERSION FORMULA (XX) >API54A
>API54B
>LPG
>EN14214
>ETH15
DENSITY AT XX 1CHOOSE PRODUCT
16CHOOSE PRODUCT
750.0 kg/m3
DENSITY AT 15 (1)
>ETH20
>FAME
>ETBE
DENSITY RANGE 500.0 kg/m3
MIN DENSITY
500.0 kg/m3
MIN DENSITY
999.9 kg/m3
MAX DENSITY
999.9 kg/m3
MAX DENSITY
XX=DENSITY TEMP. (REF)
Example for XX=15°C
6.3 Menu measuring system EMA
EMA
CORRECTION(THOUSAND)
METER COEFFICIENT
METER FLOWRATES
TEMPERATURE
VOLUMES
DETECTOR
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 20/24
This document is available at www.alma-alma.fr
6.3.1 Sub-menu METER COEFFICIENT
Set the meter coefficient of the measuring system in pulse per liter (p/l).
0.0000METER COEFFICIENT
00.0000ENTER COEFFICIENT
6.3.2 Sub-menu CORRECTION
Set the correction factor per thousand (‰) of the measuring system for a measurement with high viscosity products.
+0CORRECTION(THOUSAND)
+0ENTER CORRECTION
6.3.3 Sub-menu METER FLOWRATES
MINIMUM FLOWRATE: Set the metrological minimal flowrate of the measuring system in m3/h or L/ m3 depending on the configured flow unit. MAXIMUM FLOWRATE: Set the metrological maximal flowrate of the measuring system in m3/h or L/ m3 depending on the configured flow unit. OBJECTIVE LOW FLOW: Set the objective low flow in m3/h. In low flow phases, a regulation will be done around this value with a tolerance of ±3m3/h. This value increased by 3 must be less than the maximum flowrate.
METER FLOWRATES
18.0OBJECTIVE LOW FLOW
L kg/m3
/h
008.0ENTER MINIMUM FLOW
L kg/m3
/h
080.0ENTER MAXIMUM FLOW
L kg/m3
/h
018.0ENTER OBJECTIVE LF
L kg/m3
/h
80.0MAXIMUM FLOWRATE
L kg/m3
/h
8.0MINIMUM FLOWRATE
L kg/m3
/h
6.3.4 Sub-menu VOLUMES
MINIMUM QUANTITY: Set, in liters, the minimum measured quantity of the measuring system to guaranty the measurement (authorized volume) MANIFOLD VOLUME: Set the volume of the manifold in liters (depends on the compartments number). FIXED VOLUME: Set the end of counting fixed volume of the measuring system in liters.
200 LMINIMUM QUANTITY
0200 LMINIMUM QUANTITY
VOLUMES
24.0 LMANIFOLD VOLUME
24.0 LMANIFOLD VOLUME
5.0 LFIXED VOLUME
05.0 LFIXED VOLUME
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 21/24
This document is available at www.alma-alma.fr
6.3.5 Sub-menu TEMPERATURE
This menu os an option. It is used to calibrate the temperature into the MICROCOMPT+. Refer to FM 8510.
TEMPERATURE (XX) TEMPERATURE�OFF
TEMPERATURE�ON +99.9 °CCALIBRATE TEMP.
+99.9 °CENTER TEMPERATURE
Operating with temperature or not.
Calibration of temperature.
-20.0 °CMINIMUM TEMPERATURE
-20.0 °CENTER MINIMUM TEMP.
+50.0 °CMAXIMUM TEMPERATURE
+50.0 °CENTER MAXIMUM TEMP.
LOCKED ALARM (XX) LOCKED ALARM�OFF
LOCKED ALARM�ON
6.3.6 Sub-menu DETECTOR
Set the gas detector model for the end-of-counting probe:
3001: ATEX gas detector which status needs to be validated. The end-of-counting probe must be dry before validating the ‘dry’ status. 3000: Non ATEX gas detector.
DETECTOR (XX) DETECTOR�3001 Type of gaz detector on the manifold: ATEX (DG3001) or non-ATEX (DG3000).
DETECTOR�3000
DETECTOR�DRY
6.4 Menu DATE AND TIME
DATE AND TIME 14.41TIME (HH:MM)
Enter the day, the month and the year, and then enter hour and minutes (e.g.14.41 means 2:41 pm).
16.07.15DATE (DD.MM.YY)
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 22/24
This document is available at www.alma-alma.fr
ANNEXE
SUMMARY: PARAMETERS: Print the daily summary Print the calculator parameters
GRAVICOMPT 348+.000 BOARD v1r8VERSION 02.02.00 OF 30.06.15VEHICULE: AA-000-AAINDICATOR: 03000 PRINTED ON THE 21/07/15 at 10h20
SUMMARYOF MEASUREMENTS OF 21/07/15DAY 202 003 MEMORISED RESULTS
**** DAILY TOTALISERS ****
GO (1) : 00009908 LSP95 (2) : 00000000 LE-10 (3) : 00000000 L SP98 (4) : 00000000 LFOD (5) : 00008066 L
TOTAL FROM 1 TO 16 : 00017974 L
************** SUMMARY **************N CPT PRODUCT TEMP VOLUME 001 3 (1) GO 22.9°C *00316 L 002 3 (1) GO 22.9°C 01000 L 003 4 (5) FOD 22.9°C 01500 L 004 4 (5) FOD 22.9°C 00020 L 005 4 (5) FOD 22.9°C 01400 L 006 3 (1) GO 22.9°C 02539 L 007 3 (1) GO 22.9°C *02200 L
* : NO GUARANTEED DELIVERY
If the Temperature option is not activated, FLOW is printed instead of the product temperature 'TEMP'.
************* PARAMETERS *****************
COMPARTMENT NUMBER : 5INDEX BEGINNING : 1LF HEIGHT (MM):C1 (1234) C2(1234) C3(1234) C4(1234)C5 (1234) HEIGHT : 470 MMFLOWRATE UNIT : M3/HCOEFFICIENT : 02.9000 P/LCORRECTION COEFF : +0 °/ooMIN FLOW: 8.0 / MAX : 80.0 M3/HOBJECTIVE LOW FLOW : 18.0 M3/HMINIMUM QUANTITY : 200 LMANIFOLD VOLUME : 24.0 LFIXED VOLUME : 5.0 LTEMPERATURE : ONGAS DETECTOR : DG3001CONVERSION : VBCONVERSION FORMULA : API54BMIN DENSI:500.0 / MAX :999.9 KG/M3PRODUCT NAME CORRECT DENSITY PROD 1 GO OFF 750.0 KG/M3 PROD 2 SP95 ON 750.0 KG/M3 PROD 3 E-10 ON 750.0 KG/M3 PROD 4 SP98 ON 750.0 KG/M3 PROD 5 FOD OFF 750.0 KG/M3VOLUMES : LOW TO HIGH FLOW : 30 L HIGH TO LOW FLOW : 10 LTIMING: OPENING INCREMENT :0.070 S OPENING RELAX. :1.000 S CLOSING INCREMENT :0.070 S CLOSING RELAX. :1.000 S WET PROBE :10 S ANTI-VORTEX STOP : 5 S MANIFOLD FILLING :30 S MANIFOLD DRAINING :30 SSTOP FLOW AT 9.8 M3/H
GRAVICOMPT 348+.000 BOARD v1r8VERSION 02.02.00 OF 30.06.15VEHICULE: AA-000-AAINDICATOR: 03000 PRINTED ON THE 21/07/15 at 10h20
Instantaneous Height
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 23/24
This document is available at www.alma-alma.fr
TOTALISER: EVENTS RECORDED: Print the general totaliser Print the events recorded
********** TOTALISER **********
GENERAL TOTALISER: 00056638 L
GRAVICOMPT 348+.000 BOARD v1r8VERSION 02.02.00 OF 30.06.15VEHICULE: AA-000-AAINDICATOR: 03000 PRINTED ON THE 21/07/15 at 10h20
25 RECORD(S)
14:49:55 TEMPERATURE DEFAULT14:49:53 USER MODE14:30:03 SWITCH ON14:24:33 RESET APPLICATION...
09:47:15 METROLOGICAL MODE09:47:06 DATE MODIFICATION09:42:57 PARAM@10= 19509:12:36 PARAM@ 9= 108:59:02 PARAM@26= 13 08:58:57 PARAM@24= 1
GRAVICOMPT 348+.000 BOARD v1r8VERSION 02.02.00 OF 30.06.15VEHICULE: AA-000-AAINDICATOR: 03000 PRINTED ON THE 26/07/15 at 15h50EVENTS OF 21/07/15
DELIVERY ORDER :
********** DELIVERY **********
DELIVERY 001
COMPARTMENT : 1PRODUCT : GOMEASUREMENT 1 : 00400 LITERSMEASUREMENT 2 : 01000 LITERSMEASUREMENT 3 : 01000 LITERS
--------------------TOTAL CPT 1 : 02400 LITERS
IN CASE OF DISPUTE, THE MEASUREMENT RESULTS STORED BY THE MAIN INDICATING DEVICE PROVIDING PROOF
GRAVICOMPT 348+.000 BOARD v1r8VERSION 02.02.00 OF 30.06.15VEHICULE: AA-000-AAINDICATOR: 03000 PRINTED ON THE 22/07/15 at 9h42
FORM DOC 011 A
MU 7038 EN C GRAVICOMPT MANIFOLD Page 24/24
This document is available at www.alma-alma.fr
RELATED DOCUMENTS
GU 7038 User Guide
MV 5006 Verification Guide
FM 8000 Replacement of the backup batteries on the AFSEC and AFSEC+ electronic board
FM 8001 Diagnostic support for power supply failure
FM 8002 Diagnostic support for a display failure
FM 8003 Diagnostic support for DEB_0 or ZERO FLOW DEFAULT alarm
FM 8004 Diagnostic support for GAS or PRESENCE GAS alarm
FM 8005 Diagnostic support for METERING PROBLEM alarm
FM 8007 Diagnostic support for MEMORY LOST or DEF MEMO alarm
FM 8008 Diagnostic support for DATE alarm
FM 8010 Diagnostic support for EEPROM MEMORY LOST alarm
FM 8011 Configuration of jumpers and adjustment of metering thresholds on the AFSEC+ electronic board
FM 8510 Adjustment of a temperature chain in a MICROCOMPT+