MTC-3 Series 3 In 1 Controller Timer + Counter + Tachometer · Panel Panel Type Type DIN Rail Type...

2
Panel Type Panel Type DIN Rail Type DIN Rail Type www.maxthermo.com MTC-3 Series 3 In 1 Controller Timer + Counter + Tachometer MTC-3 Series 3 In 1 Controller Timer + Counter + Tachometer Multi-Function LCD Digital Timer / Counter / Tachometer MAXIMUM ELECTRONIC CO., LTD MAXIMUM ELECTRONIC CO., LTD MAXTHERMO - GITTA GROUP CORPORATION MAXTHERMO - GITTA GROUP CORPORATION

Transcript of MTC-3 Series 3 In 1 Controller Timer + Counter + Tachometer · Panel Panel Type Type DIN Rail Type...

Panel TypePanel Type

DIN Rail TypeDIN Rail Type

www.maxthermo.com

MTC-3 Series 3 In 1 ControllerTimer + Counter + TachometerMTC-3 Series 3 In 1 ControllerTimer + Counter + TachometerMulti-Function LCD Digital Timer / Counter / Tachometer

MAXIMUM ELECTRONIC CO., LTDMAXIMUM ELECTRONIC CO., LTDMAXTHERMO - GITTA GROUP CORPORATIONMAXTHERMO - GITTA GROUP CORPORATION

2010/03MTC-3

MTC-3 Series Timer + Counter + Tachometer 3 In 1 ControllerMTC-3 Series Timer + Counter + Tachometer 3 In 1 Controller

Support RS-232/RS-485/RS-422communication Interface modeA variety of alternativecommunication format:Communication rate: 1200~57600bps,Date Bit: 7/8bit,Parity check: N/O/E,Stop bit: 1/2bit

Quick setting and real time monitoring

A.Maxtech:Timer / Conuter/ TachomerB.Functions3 - Timer / Conuter/ Tachomer all in 1C.Output type1 - Relay2 - Transistor

D.Communiction1 - None2 - RS-2323 - RS-4224 - RS-485E.Installation1 - DIN rail2 - Panel48x48mm

F.PowerA - AC100~240V, 50/60 HzD - DC24V / AC24VAccessories1 - MTCC–015232M (RS-232 Communiction cable)2 - MTCC–015422M (RS-422 Communiction cable)3 - MTCC–015485M (RS-485 Communiction cable)

MAXTHERMO - GITTA GROUP CORPORATIONMAXIMUM ELECTRONIC CO., LTD

Note 1.The mounting panel thickness should be 1.5mm.2.To allow easier operability, it is recommended

that adapters are mounted so that the gap between sides with hooks is at least 20mm.

3.It is possible to mount counters side by side, but only in the direction without the hooks.

Panel Type

Module TypeUnit mm

Dimensions with flush mounting adapter Use a standard 35mm DIN rail for installation

60.2553

55.5

110.598

12.57.25

48

53.6

90 44.18

11.8211.15

53.6

9.41 17.2 20.6 10.0

DIN rail 35mm

35.8

4

4

6 5 4 3 2 1

OUT1 OUT2

100 to 240 VAC50 / 60 Hz

COM

12V

GATE(CP1)RESET2

RESET1SIGNAL(CP2)

12 11 78910

1 2 3 4 5 6 7 8 9GATE

CP1CP2

RESET2RESET1

SIGNAL

101112131415161718OUT1

12V

OUT2

100 to 240 VAC50 / 60 Hz

2 3 4

567

8910111213

1

AB

K/P Range

MSH

MODE

RESET

RST1 RST2 OUT1 OUT2

135

24614

15

16

17

Reset IndicatorControl Output IndicatorPresent Value (character height: 9 mm)Display time unit (no display if choosing counter)Set Value (character height: 4mm)The first setting keyThe second setting keyThe third setting key

The fourth setting keyThe fifth setting keyThe sixth setting keyReset key(resets present value and output)Mode key (changes modes and setting items)Key Protection Indicator(the default value is OFF)Set value (Range) A,B display

2

3 45

6

7

8

9

10

11

12

13

1

14

15

16

17

MTC-3 Series

MODBUS ASCII

NoteAC100-240V/AC24V/DC24V, threeoptional power supply.

12VDC external supply power candrive the external optical sensors,such as encoder, infrared switches etc.

Up to 65mm

Up to 20mm

45mm

65mm

45mm

45mm

+ 0.6- 0

+ 0.6- 0

+ 0.6- 0