Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

51
Lux LuxPro Thermostats Mt. Laurel, NJ NEW MULTI-STAGE MULTI-STAGE TOUCHSCREENS Features & Programming

Transcript of Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

Page 1: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

NEW MULTI-STAGEMULTI-STAGE

TOUCHSCREENS

Features & Programming

Page 2: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• PSPU721T – 2H/1C• PSPU732T – 3H/2C• 7 Day Programmable OR

Non Programmable (Simple Mode)• Dual Fuel Capable w/optional

Outdoor Wireless Remote Temp Transmitter.

• Manual or Auto Humidity and De-Humidity Control (PSPU732T only)

• Installer Message• Energy Watch – Calculates Usage

and Dollar Amount.• Screen Lockout• Much, Much, Much More…..

NEW MULTI-STAGE

TOUCHSCREENS

VERY COMPETITIVE PRICING

Page 3: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

NEW TOUCHSCREENFEATURES/PROGRAMMING

• On power up, to use the PSPU721 or 732 as a simple non programmable thermostat, touch the screen.

• To switch from programmable mode to simple mode, remove the faceplate, press & release the reset button on the bottom right. When “Touch For Simple Thermostat” comes up on the screen touch the screen and the t-stat will switch to “Simple” mode.

TOUCH

FOR SIMPLE

THERMOSTAT

Page 4: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Simple Mode puts the thermostat into non programmable mode where only temperature set point, cool/heat/auto mode, or fan operation can be changed.

AUTO

FAN AUTO 72F

72.0 +-

46%

NEW TOUCHSCREENFEATURES/PROGRAMMING

Page 5: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• For Programmable Mode, touch the screen. Now you can use all of the extensive programmable features to configure the thermostat the way you or the consumer wants it.

NEW TOUCHSCREENFEATURES/PROGRAMMING

TOUCH FOR

PROGRAMMABLE

THERMOSTAT

Page 6: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Home screen shows temp set points, date, time, room temp, humidity, and outdoor temp if using optional wireless temp transmitter.

• Touch the Screen anywhere to advance to Control Screen.

Heat Set Point

Cool Set Point

Outdoor Temp* RoomHumidity

NEW TOUCHSCREENFEATURES/PROGRAMMING

* With Use of Wireless Remote Transmitter

Mode Setting

Fan Setting

Run Program or Hold

Current time & date

Page 7: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• The Control Screen is for the consumer to – make Temp changes, – set Humidity to Auto or

Manual, – set Dehumidifcation – set Fan mode– put t-stat in Hold or Run

Mode– access Installers Message.

• Press Home Screen button to go back to Home Screen.

• Press MENU to go to Main Programming Screen.

RUN PROG

AUTO

FAN AUTO

MENU --DHUM

++

68.072.0

45

46%70.0

HUMIDITY MANUAL

Run Program or Hold

Auto or Manual

Installers Message Home

Screen

Current Mode Blinks

Main Programming

NEW TOUCHSCREENFEATURES/PROGRAMMING

Adjust temp and dehumidification settings

Fan Auto, Fan Intermittent or Fan On.

Auto, Cool Heat, Emerg Heat or Off Current

room temp & humidity

HEAT

COOL

Page 8: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Main Menu Programming Screen allows owner to make adjustments, settings and programming choices.

• Push Date / Time Settings

DATE / TIME SETTINGS

PROGRAM SETTINGS

ENERGY WATCH

DEHUMIDIFY

ADVANCED SETTINGS

VACATION SETTINGS

FILTER MONITOR

CLEAN SCREEN

SET SCREEN

NEW TOUCHSCREENFEATURES/PROGRAMMING

Page 9: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Set date & time by pressing each button individually.

• Press MENU to go back to Main Programming Screen

NEW TOUCHSCREENFEATURES/PROGRAMMING

DATE / TIME SETTINGS

MENU

12 33

07 20 08

PM

2412

H M

H D Y

CLOCK

SET TIME / DATE

Page 10: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Push “Program Settings” to set daily temperature and fan settings.

DATE / TIME SETTINGS

PROGRAM SETTINGS

ENERGY WATCH

DEHUMIDIFY

ADVANCED SETTINGS

VACATION SETTINGS

FILTER MONITOR

CLEAN SCREEN

SET SCREEN

NEW TOUCHSCREENFEATURES/PROGRAMMING

Page 11: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Press day of week• 4 on/off periods per day. • Each day can be

programmed differently.• Fan can be set differently

for each period.• Each day can be copied

to the next.

NEW TOUCHSCREENFEATURES/PROGRAMMING

PROGRAM SETTINGS

TUMO WE TH FR SA SU

AM3007

1

MENUHEAT COOL

FAN AUTOEVENT

START

- +68.072.0

Page 12: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• After completing each day’s program, when you push the next day, the user is asked if they want to copy to the next day.

• If YES, then you will continue to the following day and be asked the question again, etc.

• If NO, then you program that day as you wish and proceed on to all the days of the week.

• Press MENU when complete to go back to the Main Programming Screen.

NEW TOUCHSCREENFEATURES/PROGRAMMING

YES NO

COPY MONDAYSETTINGS

PROGRAM SETTINGS

Page 13: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Push “Energy Watch” to see HVAC energy consumption and cost to date.

DATE / TIME SETTINGS

PROGRAM SETTINGS

ENERGY WATCH

DEHUMIDIFY

ADVANCED SETTINGS

VACATION SETTINGS

FILTER MONITOR

CLEAN SCREEN

SET SCREEN

NEW TOUCHSCREENFEATURES/PROGRAMMING

Page 14: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Energy Watch shows energy consumption for up to 255 days based on parameters set in “Advanced Settings”.

• Owner can see energy usage and cost at anytime.

• Hit the RESET button to zero out.

ENERGY WATCH

NEW TOUCHSCREENFEATURES/PROGRAMMING

MENU

RESET

LAST 30 DAYS150 HRS COMP. 20 HRS FURN.120 HRS FAN290 HRS TOTAL

COST $20.30

Page 15: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• By touching the Clean Screen button, you freeze the screen for 15 seconds so that you can wash/wipe it w/o changing any settings.

CLEAN SCREEN

DATE / TIME SETTINGS

PROGRAM SETTINGS

ENERGY WATCH

DEHUMIDIFY

ADVANCED SETTINGS

VACATION SETTINGS

FILTER MONITOR

CLEAN SCREEN

SET SCREEN

NEW TOUCHSCREENFEATURES/PROGRAMMING

Consult owners manual for maintenance & care

Page 16: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Push “Set Screen” to change screen settings.

DATE / TIME SETTINGS

PROGRAM SETTINGS

ENERGY WATCH

DEHUMIDIFY

ADVANCED SETTINGS

VACATION SETTINGS

FILTER MONITOR

CLEAN SCREEN

SET SCREEN

NEW TOUCHSCREENFEATURES/PROGRAMMING

Page 17: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Backlight – Can be set to Constant Light or Auto (touch the screen).

• Reverse – Change from B/W to W/B.

• Night Reverse - Set for Auto screen reverse (chgs at 9PM and 6AM).

NEW TOUCHSCREENFEATURES/PROGRAMMING

MENU 07

ON

ON

AUTO BACKLIGHT

REVERSE

NIGHT REVERSE

CONTRAST

SET SCREEN

Page 18: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Push “Vacation Settings” to set parameters for time & temperature while away from the home.

DATE / TIME SETTINGS

PROGRAM SETTINGS

ENERGY WATCH

DEHUMIDIFY

ADVANCED SETTINGS

VACATION SETTINGS

FILTER MONITOR

CLEAN SCREEN

SET SCREEN

NEW TOUCHSCREENFEATURES/PROGRAMMING

Page 19: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Input leave (BEGIN) date, return (END) date and heat/cool temp settings.

NEW TOUCHSCREENFEATURES/PROGRAMMING

VACATION SETTINGS

0830

09

09

HEAT COOL

20BEGIN

END

- +65.080.0

VACATION SETTINGS

08

Page 20: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Push “Filter Monitor” to see filter usage in days and to reset after changing filter.

DATE / TIME SETTINGS

PROGRAM SETTINGS

ENERGY WATCH

DEHUMIDIFY

ADVANCED SETTINGS

VACATION SETTINGS

FILTER MONITOR

CLEAN SCREEN

SET SCREEN

NEW TOUCHSCREENFEATURES/PROGRAMMING

Page 21: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Filter Monitor Screen shows how many days current filter has been used (based on fan run time).

• Reset button will set back to zero.

NEW TOUCHSCREENFEATURES/PROGRAMMING

MENU

RESET

FILTER

USED 15 DAYS

FILTER MONITOR

Page 22: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Push this button to toggle between “Humidify” or “Dehumidify” mode.

• More detailed settings for humidity control are available in Advanced Settings. (Installer settings)

HUMIDITY SETTINGS

DATE / TIME SETTINGS

PROGRAM SETTINGS

ENERGY WATCH

DEHUMIDIFY

ADVANCED SETTINGS

VACATION SETTINGS

FILTER MONITOR

CLEAN SCREEN

SET SCREEN

NEW TOUCHSCREENFEATURES/PROGRAMMING

Page 23: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Push & hold the Advanced Settings button for 5 seconds and the installer will be allowed to make additional and more detailed program settings.

• The following screen will appear when entering Advanced Settings:

ADVANCED SETTINGS

DATE / TIME SETTINGS

PROGRAM SETTINGS

ENERGY WATCH

DEHUMIDIFY

ADVANCED SETTINGS

VACATION SETTINGS

FILTER MONITOR

CLEAN SCREEN

SET SCREEN

NEW TOUCHSCREENFEATURES/PROGRAMMING

CAUTION: Altering the system properties in the ADVANCED SETTINGS may affect the performance of the HVAC system and should be performed only by a qualified installer.

Page 24: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Advanced Settings Screen allows installer to set:– Daylight Savings On/Off– Filter Days– Energy Usage Parameters– Celsius or Fahrenheit– Security level– Installers message

• Press FILTER to set Filter Monitor to Off/On & number of days to monitor.

NEW TOUCHSCREENFEATURES/PROGRAMMING

ADVANCED SETTINGS

INSTALL MESSAGE

SECU-RITY

FILTER

MENU

ENERGY WATCH

DAYLIGHT TIME

F

OFF

NEXT PAGE

Page 25: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Turn Filter Monitor Off or ON.

• An icon appears on the Home Screen when the Filter monitor is set to ON.

NEW TOUCHSCREENFEATURES/PROGRAMMING

MENU

OFF

FILTER MONITOR

FILTER MONITOR

ADVANCED SETTINGS

Page 26: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• When you turn THE Filter Monitor ON, screen will then ask for the number of months (up to 6), based on fan run time, to notify consumer to change filter.

NEW TOUCHSCREENFEATURES/PROGRAMMING

MENU

2

CHANGE FILTER

FILTER MONITOR

ADVANCED SETTINGS

AFTER MONTH

Return to Advanced Settings Screen

Page 27: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Push “Energy Watch” to set parameters for tracking HVAC energy usage and cost.

NEW TOUCHSCREENFEATURES/PROGRAMMING

ADVANCED SETTINGS

INSTALL MESSAGE

SECU-RITY

FILTER

MENU

ENERGY WATCH

DAYLIGHT TIME

F

OFF

NEXT PAGE

Page 28: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Set consumption KW parameters for compressor, furnace & fan, and per hr KW cost.

• This allows consumer to watch on going HVAC energy costs by pushing the “Energy Watch” button on the Main Menu Screen.

NEW TOUCHSCREENFEATURES/PROGRAMMING

MENU 13

1

5

5 COMPRESSOR KW

FURNACE KW

FAN KW

C / KWHr

ENERGY WATCH

ADVANCED SETTINGS

Return to Advanced Settings Screen

Page 29: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Push “Security” to set level of screen lock preferred.

NEW TOUCHSCREENFEATURES/PROGRAMMING

ADVANCED SETTINGS

INSTALL MESSAGE

SECU-RITY

FILTER

MENU

ENERGY WATCH

DAYLIGHT TIME

F

OFF

NEXT PAGE

Page 30: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• To turn Security on to FULL Lock or PARTIAL Lock, push OFF button.

• You will be asked for a Pin #. The default Pin # is 1111.

• To change your Pin # push Change Pin and follow the prompts.

NEW TOUCHSCREEN

FEATURES/PROGRAMMING

MENU

OFF

SECURITY

SECURITY

ADVANCED SETTINGS

FULL LOCK

CHANGE PIN

Page 31: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Push the Lock button to toggle between FULL Lock and PARTIAL Lock

• FULL Lock completely locks out the thermostat from unauthorized use w/o the Pin #

• PARTIAL Lock only allows the changing of the temperature setpoint.

NEW TOUCHSCREEN

FEATURES/PROGRAMMING

MENU

OFF

SECURITY

SECURITY

ADVANCED SETTINGS

FULL LOCK

CHANGE PIN

Return to Advanced Settings Screen

Page 32: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Push “Install Message” to input installer message and set frequency of display.

NEW TOUCHSCREENFEATURES/PROGRAMMING

ADVANCED SETTINGS

INSTALL MESSAGE

SECU-RITY

FILTER

MENU

ENERGY WATCH

DAYLIGHT TIME

F

OFF

NEXT PAGE

Page 33: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Message of up to 42 characters.

• Message can be programmed to appear on a monthly basis.

• Message can also be accessed by consumer by pushing theicon button on the Control Screen.

NEW TOUCHSCREENFEATURES/PROGRAMMING

INSTALL MESSAGE

1 ABC

3 GHI

OK

For Service Call ABC Htg at 777-555-4321

ADVANCED SETTINGS

MENU

2 DEF

4 JKL

5 MNO

6 PQR

7 STU

8 VWX

9 YZ

0 :/-

Page 34: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Push “Next Page” to access Advanced settings for system type, cycles rates, staging temps, dual fuel, humidity and more…

NEW TOUCHSCREENFEATURES/PROGRAMMING

ADVANCED SETTINGS

INSTALL MESSAGE

SECU-RITY

FILTER

MENU

ENERGY WATCH

DAYLIGHT TIME

F

OFF

NEXT PAGE

Page 35: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Select type of HVAC system.

• Set Max Compressor Cycle Rate per Hr. (2 - 9)*

• Auto Change is minimum temp (dead band) difference between Heat/Cool set points. (1 – 5 )*

* factory settings are recommended

NEW TOUCHSCREENFEATURES/PROGRAMMING

ON

40+MENU

NEXT PAGE

PREV PAGE

HEAT PUMP 9

ELECTRIC FURNACE

HP CUT OFF

CUT TEMP

CYCLE RATE

3 AUTO CHNGE

• Heat Pump• 2 Stg HP• A/C• No Compressor

• Electric Furnace• Gas Furnace• 2 Stg Gas Furn.• Oil Furnace

ADVANCED SETTINGS

PUSH NEXT FOR FURTHER SETTING

Page 36: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Heat Pump Cut Off is for Dual Fuel applications. By turning the HP CUT OFF to ON, and setting the CUT TEMP (outside), the HP will shut down at that CUT TEMP and the gas furnace will take over.

• Press NEXT PAGE for further settings

NEW TOUCHSCREENFEATURES/PROGRAMMING

ON

36+MENU

NEXT PAGE

PREV PAGE

HEAT PUMP 9

ELECTRIC FURNACE

HP CUT OFF

CUT TEMP

CYCLE RATE

3 AUTO CHNGE

ADVANCED SETTINGS

DUAL FUEL

Page 37: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Allows heat pump to operate with the furnace by changing to the ON position.

• Press NEXT PAGE for further settings

NEW TOUCHSCREENFEATURES/PROGRAMMING

MENU

PREV PAGE

HP WHEN

NEXT PAGE

OFF

FURNACE ON

ADVANCED SETTINGS

DUAL FUEL

Page 38: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• 1st Stage Differential is the temp difference from set point that the heat or cool initiates.

• 2nd Stage Differential is the temp difference from 1st stg set point & 2nd stg start-up.

• 3rd Stage…• Set the reversing valve to

energize in Heat or Cool depending on unit design

NEW TOUCHSCREENFEATURES/PROGRAMMING

MENU COOL

2

2

2 1ST STAGE DIF

2ND STAGE DIF

3RD STAGE DIF

OB ENERGIZED

NEXT PAGE

PREVPAGE

PUSH NEXT FOR FURTHER SETTING

ADVANCED SETTINGS

MULTI-STAGE DIFFERENTIAL

SETTINGS

Consult equipment manufacturer’s operation/installation manuals before setting these temperature settings.

Page 39: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• This time setting brings on 2nd stage (heat or cool) if system has not been able to reach the 2nd stage temperature setpoint.

• This avoids excessive compressor run time by bringing on the 2nd stage and full system capacity to meet setpoint.

NEW TOUCHSCREENFEATURES/PROGRAMMING

MENU

PREV PAGE

IF STAGE 1 RUNS

NEXT PAGE 0

TURN ON STAGE 2

ADVANCED SETTINGS

MINUTES

MULTI-STAGE DIFFERENTIAL

SETTINGS

PUSH NEXT FOR FURTHER SETTING

Consult equipment manufacturer’s operation/installation manuals before setting these temperature settings.

Page 40: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Humidity Fan – When set to ON the fan will run when there is an independent call to humidify. When set to OFF, fan only runs during heating or cooling cycles.

• De-Humidity Fan – Same as above.

NEW TOUCHSCREENFEATURES/PROGRAMMING

MENU OFF

OFF

OFF

OFF HUM FAN

DH FAN

DH REVERSE

DHCONTCOMP

NEXT PAGE

PREVPAGE

ADVANCED SETTINGS

HUMIDITY CONTROL

Page 41: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• DH REVERSE:

• ON - DH relay is normally closed when relative humidity is above DH set point.

• OFF - DH relay is normally open when relative humidity is below DH set point.

NEW TOUCHSCREENFEATURES/PROGRAMMING

MENU OFF

OFF

OFF

OFF HUM FAN

DH FAN

DH REVERSE

DHCONTCOMP

NEXT PAGE

PREVPAGE

ADVANCED SETTINGS

HUMIDITY CONTROL

Page 42: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• DH CONTROL COMPRESSOR:

• ON - Thermostat will turn off the air conditioning if either the dehumidify set point or the temperature set point is reached, whichever comes first, both DH relay and compressor will turn off.

• OFF - DH relay is independent of compressor activity (DH becomes a spare relay and can be used for a variable speed fan or separate dehumidifier or air exchanger)

NEW TOUCHSCREENFEATURES/PROGRAMMING

MENU OFF

OFF

OFF

OFF HUM FAN

DH FAN

DH REVERSE

DHCONTCOMP

NEXT PAGE

PREVPAGE

ADVANCED SETTINGS

HUMIDITY CONTROL

Page 43: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• This screen allows you to calibrate temperature or relative humidity if found to be off.

• Temperature accuracy is set at +/-1 degree. It can be adjusted +/- 9.5.

• Humidity accuracy is +/- 4%. It can be adjusted +/- 20%.

• Press NEXT PAGE for further settings

NEW TOUCHSCREENFEATURES/PROGRAMMING

MENU

PREV PAGE

HUM

0

ADVANCED SETTINGS

TEMP 0

0

++

Page 44: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• HRV/ERV units can be controlled by simply connecting the DH terminal on the thermostat to the terminal DH of the HRV/ERV. Most HRV/ERV units will control properly with the DH REVERSE feature turned off (contact normally open).

• OPTION 1: In Advanced Settings choose DH ControlComp, set to ON then lower the temperature to a minimum safe set point, then set the desired de-humidity level. De- humidify will control the compressor (unless minimum temperature set point is reached) whichever comes first.

NEW TOUCHSCREENFEATURES/PROGRAMMING

De-humidification options for increasing comfort and efficiency

Page 45: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• OPTION 2: Connect terminal DH to Y1 and set thermostat to de-humidify mode. Then regardless of temperature the de-humidification setting will have priority. Caution: This method will run the compressor until the de-humidification level is reached and may cause overcooling.

NEW TOUCHSCREENFEATURES/PROGRAMMING

De-humidification options for increasing comfort and efficiency

Page 46: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• OPTION 3: Connect the DH terminal to a variable speed fan control, (set DH REVERSE to control the fan so that low speed is activated to de-humidify). This method provides maximum comfort while maintaining the temperature in cooling mode.

NEW TOUCHSCREENFEATURES/PROGRAMMING

De-humidification options for increasing comfort and efficiency

Page 47: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

• Optional Wireless Remote Outdoor Temperature Transmitter for PSPU7 multi-stage touchscreens. Used for DUAL FUEL & AUTOMATIC HUMIDITY CONTROL of central humidifier.

NEW TOUCHSCREENWireless Remote Temp Transmitter

Mounting Bracket

Indoor Receiver(plugs in at bottom of t-stat and mounts under t-stat cover)

Optional Outdoor Wireless Remote Temp Transmitter Kit #WTR064

Page 48: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

NEW TOUCHSCREENWireless Remote Indoor Receiver

Plug Indoor Receiver into plug located at bottom of PSPU t-stat

Indoor Receiver Unit installed

PSPU Thermostat Screen

Push Reset button on Indoor Receiver to initiate communication between Outdoor transmitter and Inside Receiver.

Plug antenna wire from Indoor Receiver into plug located at bottom right of PSPU t-stat

Page 49: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

WIRING LEGEND

TERMINAL EQUIPMENT STANDARD COLORY1 First Heat Pump YellowYellow

and/or ACG Fan GreenW2 First Stage Furnace WhiteOBW Reverse Valve or Orange

Second Stage FurnaceRH 24v Heat Transformer RedY2 Second Heat Pump Unknown

and/or ACC Common BlueH Humidity Control UnknownDH Dehumidify Control Unknown

Variable Fan ControlRC 24v Cool Transformer Unknown11 and 12 Not Used

NOTE: The above colors are standard in HVAC industry. The wiring should be confirmed before installation

12 11 RC DH H C Y2 RH OBW W2 G Y1

Page 50: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

TECHNICAL SUPPORT

• For more information, tech sheets, submittals, please refer to the Instruction or Engineering Manuals, or access the LuxPro web site at www.luxproproducts.com.

• Problems with installation or troubleshooting, please call our Technical Support team at (856) 234-8803 Ext. 7 (5:30AM – 2PM PST)

It is best if contractor is on jobsite when calling Tech Support

Page 51: Mt. Laurel, NJ MULTI-STAGE NEW MULTI-STAGE TOUCHSCREENS Features & Programming.

LuxLuxProThermostats

Mt. Laurel, NJ

LuxPro ’s Full Line of Residential & Light Comm’l Thermostats offer you the

best VALUE.Thanks for viewing our

Touchscreen Presentation